REPORT OF FOUNDATION PAD COMPACTION
Drawdy Brothers Report Date: June.15, 2007
2945 West Midway Road �04 Project No: 1314
Fort Pierce, FL 34982 NAIF® Lab No: 1
2959, 2961, 2963 West Midway Road * 4C eY Permit No: 0703-041 7
Fort Pierce, St. Lucie County, Florida a CDUP)(�r
Density tests and -Hand Cone Penetrometer (HCP) readings were made at a minimum of three locations in
the building pad. Density tests were performed in the upper one foot of fill. HCP readings were taken in
hand auger boreholes at one foot intervals from slab grade through the depth of fill. The density tests were
performed in general compliance with ASTM D 2922. The HCP test, in conjunction with information about
the soil type, is empirically correlated to the relative density of subsurface soils.
pensity
'Pest No.
Date
Tested
Location
Elevation
(feet)
Dry De ' (
Percent
Compaction
In Place
Proctor
1
6/15/07
Northwest Corner
0-1
116.4
1 117.2
99.3
2
Center Area
0-1
115.5
117.2
98.5
3
Southeast Comer
0-1
115.8
117.2
98.8
* All elevations are below bottom of slab.
The depth of the fill was approximately one foot. The fill should extend at least five feet beyond the
building perimeter. At the time of our testing no information was available regarding the foundation pad
setbacks.
In the locations and depths that were tested, the fill has been compacted to a minimum of 95 percent of the
modified Proctor maximum dry density (ASTM D 1557). No soil borings were performed below the
rei ently placed fill.