Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017:
FLOIRIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
I
Project Name: WYNNE THE ROYALE
Builder Name: WYNNE
street: I. WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
8cA
City, State, Zip: FT. PIERCE, FL,
Permit Number:
��11
,VED
\ �� Owner: � �S '�.Q,� (�
Jurisdiction:
.
"C By
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate
Zone 2 )CUC% C
1. New construction or existing New (From Plans)
9. Wall Types (1688.7 sqft.)
Insulation Area
2. Single family or M,.ultiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1448.70 ft'
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. N/A
R=11.0 240.00 ft'
:R= ft'
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1720.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1720.00 ft'
6. Conditioned floor area above grade (ft') 1720
b. N/A
R= ft'
Condit oned floor, area below grade (W) 0
. NIAucts
R
11.
R ft'
7. Windows(155.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: SgI, U=0.54 115.42 ft'
SHGC: SHGC=0.25
b. U-Factor: SgI, U=0.55 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (1720.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade L',dge Insulation R=0.0 1720.00 ft'
b. Conservation features
EF: 0.970
b. N/A • R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 56.15
PASS
Total Baseline Loads: 56.24
i
I hereby certify that the plans and specifications covered by
Review of the plans and
tVIE STgl�
this calculation are in compliance with the Florida Energy
specifications covered by this
O4
Code.
calculation indicates compliance
i„ 9j
with the Florida Energy Code.
q�
h ar,"•," :', : ;•;,.,•, „ O
PREPAR D Y.
Before construction is completed
+
DATE: --T
this building will be inspected for
compliance with Section 563.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
WE
OWNERY��A1T:
�
BUILDING OFFICIAL:
DATE: S
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factorysealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope! leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
i
LE Copy
I
4/3/2018;11:36 AM. EnergyGauge® USA- FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE ROYALE
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1720
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE
Rotate Angle: 135
Street:
WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1720 13760
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM
343 2744 No
0
1
1 Yes
Yes
Yes
2 WIC
63 504 No
0
1 No
Yes
Yes
3 M. BATH
56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN
172 1376 Yes
0
1 No
Yes
Yes
5 BASH
45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY
98 784 No
0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
528 4224 No
0
1 Yes
Yes
Yes
10 BEDROOM 3
169 1352 No
1
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
343 ft2
___
0 1
0
2 Slab -Oh -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -Oh -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
----
0 1
0
4SIab-On-Grade Edge Insulatio
KITCHEN 1 ft 0
172 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 fill
----
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 42.6 ft 0
204 f12
----
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 6.3 ft 0
98 ft2
__--
0 1
0
4/3/2018111:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8SIab-On-Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab
-On -Grade Edge Insulatio GREAT/DINING 48 ft 0
528 ft'
----
0
1
0
1 OSlab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0
169 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Gable or Shed Metal 1813 ft2
286 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
, Full attic Vented
150
1720 ft'
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
343 ft2
0.1
Wood
2
Under Attic(Vented) WIC
30
Blown
63 ft2
0.1
Wood
3
Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown
172 ft2
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
,7
Under Attic (Vented) ENTRY
30
Blown
98 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528 ft2
0.1
Wood
10
Under Attic (Vented) BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Below
0
1
N=>SE
Exterior Concrete Block - Ext InS®EDROOM
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
2
S=>NW
Exterior Concrete Block - Ext InS®EDROOM
4.1 29
0 8
0
232.0 ft2
0
0
0.5
0
3
W=>NE
Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
_ 4
S=>NW
Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
5
N=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
6
N=>SE
Exterior Concrete Block - Ext InfiIEDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
7
NE=>S
Exterior Concrete Block - Ext In�DROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.5
0
8
E=>SW
Exterior Concrete Block- Ext InfiffDROOM 2
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
9
SE=>W
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.5
0
10
S=>NW
Exterior Concrete Block - Ext IndIEDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
11
NE=>S
Exterior Concrete Block - Ext Insul ENTRY
4.1 1
5 8
0
11.3 ft2
0
0
0.5
0
12
E=>SW
Exterior Concrete Block - Ext Insul ENTRY
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
4/3/2018 11:36 AM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 3 of 5
FORM R405-2017
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Belo w
_13 S=>NW Exterior Concrete Block- Ext InsdtAUNDRY 4.1 6 0 8
14 N=>SE Exterior Concrete Block - Ext Ins3i REAT/DINT 4.1 28 0 8
15 W=>NE Exterior Concrete Block - Ext Ins©REAT/DINI 4.1 20 0 8
16 N=>SE Exterior Concrete Block - Ext IndIEDROOM 3 4.1 13 0 8
17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8
0 48.0 ft'
0 224.0 ft'
0 160.0 ft'
0 104.0 ft'
240.0 ft'
0
0
0
0
0 0.5
0 0.5
0 0.5
0 0.5
0.23 0.5
0
0
0
0
0
DOORS
# Ornt Door Type Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1 E=>SW Insulated ENTRY
None
.39 3
6 8
20 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
e Wall
V # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1 W=>NE 3 Metal Low-E Single Yes
2 S=>NW 4 Metal Low-E Single Yes
3 E=>SW 8 Metal Low-E Single Yes
4 N=>SE 14 Metal Low-E Single Yes
5 W=>NE, 15 Metal Low-E Single Yes
6 N=>SE 16 Metal Low-E Single Yes
0.54 0.25 N
0.54 0.25 N
0.54 0.25 N
0.54 0.25 N
0.55 0.25 N
0.54 0.25 N
32.4 ft' 1 ft 0 in
6.9 ftz 1 ft 0 in
23.2 ft' 1 ft 0 in
36.8 ft' 1 It 0 in
40.0 ft' 10 ft 0 in
16.2 ft' 1 ft 0 in
1 It 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 It 4 in
1 ft 4 in
Drapes/blinds
None
None
None
None
None
Exterior 5
None
None
None
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 ft' 300 ft'
30 It
8 ft
11
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1605.3 88.13 165.74 .2598
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit/ Split
SEER: 15 34.8 kBtu/hr
cfm
0.85 1
sys#1
4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft'
DUCTS
--- Supply ---
-- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic
6 325 ft'
Attic
85 ft' Default Leakage
Attic
(Default) (Default)
1 1
'
TEMPERATURES
Programable Thermostat:
Cr[eiilling Fans:Coolin
Jan
JNov
Vent
]�Y
Feb
rD[[�C�
Mar
Apr
M:yri4 ]] [[ ]]
May Jun Jul
r[[[ ]] Au
[[ ]]
[[r[- ]]
[rX,]
Dee
[r
ng an
[ ]
lxl
[
] lxl lXl
lXJ Aug
lXl Sep
l�J
Oct
[X] Nov
[ Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (VVEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (VVEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
r
4/3/2018 11:36 AMA,'
EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, State, Zip: ,'. FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce ,
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing, material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
'
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space wall§.
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class 1 vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed lightfixturesinstalled in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
•
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed f
When required tobe sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. in addition, inspection Or iog watts_ snau oe in accoraance with the provisions of IGG-400.
4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
.ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
i
3. Number of units, if multiple family
4. Number; of Bedrooms
5. Is this a'worst case?
6. Conditioned floor area (ft2)
7. Windows*. Description
a. U-Factor. Sgl, U=0.54
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55
SHGC: SHGC=0.25
c. U-Factor: N/A
SHGC:
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
WYNNE DEV., FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1448.70 ft2
b. Frame - Wood, Adjacent
R=11.0
240.00 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1720.00 ft2
1720
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
115.42 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
ft2
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.8
HSPF:8.50
3.316 ft.
0,250
Insulation
Area
14. Hot water systems
Cap:
40 gallons
R=0.0
1720.00 ft2
a. Electric
EF: 0.97
R=
ft2
R=
ft2
b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: ��1 Date:
I
Address of New Home:\ \,Q S d2 (,tom �7 City/FL Zipl;�� �P�P
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techstipport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters, For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1