Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Floi ida Department of Business and Professional Regulation - Residential Performance Method Project Nlame: WYNNE THE ROYALE Builder Name: WYNNE Street: I WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PI)2CE Permit Number: Owner: C,j ��9- 9 Jurisdiction: Design Location: FL,, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1688.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft' b. Frame - Wood, Adjacent R=11.0 240.00 ft' 3. Number lof units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1720.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ft= 6. Conditioned floor area above grade (ft') 1720 b. N/A R= ft' Conditioned Floor area below grade (ft� 0 c. R= ft 11. Ducts R ft' 7. Windows(155.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor. Sgl, U=0.54 115.42 ft' SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump sICA s,� 34.8 HSPF:8.50 SHGC: D , Area Weighted Average Overhang Depth: 3.316 ft. Qt411 oN► Area Weighted Average SHGC: 0.250 14. Hot water systems Electric Cf� CO40 8. Floor Types (1720.0 sgft.) Insulation Area a. gallons UV: U" J' a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Total Proposed Modified Loads: 56.15 Area: 0.090 PASS Total Baseline Loads: 56.24 1 hereby clirtify that the plans and specifications covered by Review of the plans and Sri this calculation are in compliance with the Florida Energy specifications covered by this O401E y „ _ ; O� Code. calculation indicates compliance �O with the Florida Energy Code. r, rux,.. •.; ,;-%.';•q;; . ;, PREPAR Before construction is completed + O DATE: this building will be inspected for c9'�'o a compliance with Section 553.908 I hereby c rtify that this building, as designed, is in compliance Florida Statutes. 5� with the Fli ride Energy Code W'E O OWNER/A T �- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in actor th 4.Copy quires an 402 envelope eakage test report with envelope leakage no greater than 7.00 ACH50 ( 12). 4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE ROYALE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1720 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number . Name Area Volume 1 Entire House 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 343 ft' ---_ 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 fN ___- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft' ---- 0 1 0 5SIab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft' -_-- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ft' ---- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 6.3 It 0 98 ft' ---- 0 1 0 4/3/2018 1:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft' ___ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft' ____ 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft' ____ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1813 ft' 286 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 tinder Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 98 ft' 0.1 - Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 528 ft' 0.1 Wood 10 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1. Wood WALLS )rnt Adjacent Space Cavity Width TO Vvnil Type Height Sheathing Framing Solar Below 0 1 N=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 9 0 8 0 72.0 ft' 0 0 0.5 0 2 Si >NW Exterior Concrete Block- Ext Insi3EDROOM 4.1 29 0 8 0 232.0 ft' 0 0 0.5 0 3 W=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.5 0 4 Si >NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft° 0 0 0.5 0 5 tJ=>SE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.5 0 6 - NI=>SE Exterior Concrete Block - Ext InfiEDROOM 2 4.1 14 0 8 0 112.0 ft" 0 0 0.5 0 7 NE=>S Exterior Concrete Block - Ext InfiEDROOM 2 4.1 2 10 8 0 22.7 ftz 0 0 0.5 0 8 E >SW Exterior Concrete Block - 6d InQEDROOM 2 4.1 9 0 8 0 72.0 ft' 0 0 0.5 0 9 SE=>W Exterior Concrete Block - Ext InfiEDROOM 2 4.1 2 10 8 0 22.7 ft' 0 0 0.5 0 _10 Si>NW Exterior Concrete Block -Ext InQEDROOM2 4.1 14 0 8 0 112.0 ft' 0 0 0.5 0 11 NE=>S Exterior Concrete Block - Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft' 0 0 0.6 0 12 E >SW Exterior Concrete Block - Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft' 0 0 0.5 0 4/3/2018 1:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 13 S=>NW Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.5 0 14 I Exterior Concrete Block - Ext Irs REAT/DINI 4.1 28 0 8 0 224.0 ft' 0 0 0.5 0 _ INI=>SE 15 =>NE Exterior Concrete Block - Ext Ins REAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.5 0 _ 16 N=>SE Exterior Concrete Block - Ext InfiffDROOM 3 4.1 13 0 8 0 104.0 ft 0 0 0.5 0 _ 17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8 240.0 ft' 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 ,E=>SW Insulated ENTRY None .39 3 6 8 20 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 11 W=>NE 3 Metal Low-E Single Yes 0.54 0.25 N 32.4 ft' 1 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S=>NW 4 Metal Low-E Single Yes 0.54 0.25 N 6.9 ft' 1 ft0 in 1 ft 4 in None None 3 E=>SW 8 Metal Low-E Single Yes 0.54 0.25 N 23.2 ft' 1 ft 0 in 1 ft 4 in None None 4 N=>SE 14 Metal Low-E Single Yes 0.54 0.26 N 36.8 ft' 1 ft 0 in 1 ft 4 in None None 5 W=>NE 15 Metal Low-E Single Yes 0.55 0.25 N 40.0 ft' 10 ft 0 in 1 ft 4 in None None 6 N=>SE 16 Metal Low-E Single Yes 0.54 0.25 N 16.2 ft' 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 300 ft' 300 ft' 30 ft 8 ft 11 INFILTRATION # Sops Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholihouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 4/3/2018 11:36 AM . EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None I SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS Supply ---- -- Return -- Air CFM 25 CFM25 HVAC# # Locatio--n R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 325 ft' Attic 85 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan F r[[[X�]] [ Jun [[ ]] [ ] [ ] [� ]j r[X,] Dee eat ng Jan Feb Mar Apr Jun [X] Jul May Aug Sep L.l Oct Nov Nov Dec Venting lxJ IXl Jun [[ ]] Jul EX] ] Aug EX] ]Sep ll�xll [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling AM 78 78 78 78 78 78 78 78 78 78 78 78 iEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/3/2018 �11:36 AM I EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name:' WYNNE THE ROYALE Builder Name: WYNNE Street: . WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: . FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in an dropped ceiling/soffit /soffit shall be aligned with y pp g g The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and ' continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors i The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the • bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to I exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and wirqna Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. ElectricaUphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover nlates and walls or ceilmnag a. In aooltion, Inspection of log walls snail be In accordance with the provisions of ICC-400. 4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEV., FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft- 2. Single family or multiple family Single-family b. Frame - Wood, Adjacent R=11.0 240.00 ft- 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1720.00 ft' 6. Conditioned Floor area (W) 1720 b. N/A R= ft2 7. Windows" Description Area c. DuctR= ff=z a. U-Factor: ,�• Sgl, U=0.54 115.42 ft' 11 a. Sup: Attic, Ret: Attic, AH: Attic 6 325 SHGF: ' ' SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: ' N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.316 ft. Area We Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2EF: 0.97 b. N/A R= ft2 c. N/A R= R2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant f c/ Builder Signature: - Date: Address Or New Home: City/FL Zip�S� r This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient e (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at port@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of Rate'ts. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Sion's support staff. required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8 11:36 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1