HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Floi ida Department of Business and Professional Regulation - Residential Performance Method
Project Nlame: WYNNE THE ROYALE
Builder Name: WYNNE
Street: I WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PI)2CE
Permit Number:
Owner: C,j ��9- 9
Jurisdiction:
Design Location: FL,, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1688.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft'
b. Frame - Wood, Adjacent
R=11.0 240.00 ft'
3. Number lof units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 3
d. N/A
R= ft'
5. Is this a worst case? Yes
10. Ceiling Types (1720.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1720.00 ft=
6. Conditioned floor area above grade (ft') 1720
b. N/A
R= ft'
Conditioned Floor area below grade (ft� 0
c.
R= ft
11. Ducts
R ft'
7. Windows(155.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor. Sgl, U=0.54 115.42 ft'
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft'
a. Electric Heat Pump sICA s,� 34.8 HSPF:8.50
SHGC:
D ,
Area Weighted Average Overhang Depth: 3.316 ft.
Qt411
oN►
Area Weighted Average SHGC: 0.250
14. Hot water systems
Electric
Cf� CO40
8. Floor Types (1720.0 sgft.) Insulation Area
a.
gallons
UV:
U" J'
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor
Total Proposed Modified Loads: 56.15
Area: 0.090
PASS
Total Baseline Loads: 56.24
1 hereby clirtify
that the plans and specifications covered by
Review of the plans and
Sri
this calculation
are in compliance with the Florida Energy
specifications covered by this
O401E
y „ _ ; O�
Code.
calculation indicates compliance
�O
with the Florida Energy Code.
r, rux,.. •.; ,;-%.';•q;; . ;,
PREPAR
Before construction is completed
+ O
DATE:
this building will be inspected for
c9'�'o a
compliance with Section 553.908
I hereby c
rtify that this building, as designed, is in compliance
Florida Statutes.
5�
with the Fli
ride Energy Code
W'E O
OWNER/A
T �-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in actor th 4.Copy
quires an
402
envelope eakage test report with envelope leakage no greater than 7.00 ACH50 ( 12).
4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE ROYALE
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1720
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE
Rotate Angle: 135
Street:
WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V
Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number
. Name
Area Volume
1
Entire House
1720 13760
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
BEDROOM
343 2744 No 0
1
1 Yes
Yes
Yes
2
WIC
63 504 No 0
1 No
Yes
Yes
3
M.BATH
56 448 No 0
1 Yes
Yes
Yes
4
KITCHEN
172 1376 Yes 0
1 No
Yes
Yes
5
BATH
45 360 No 0
1 Yes
Yes
Yes
6
BEDROOM 2
204 1632 No 0
1
1 Yes
Yes
Yes
7
ENTRY
98 784 No 0
1 Yes
Yes
Yes
8
LAUNDRY
42 336 No 0
1 Yes
Yes
Yes
9
GREAT/DINING
528 4224 No 0
1 Yes
Yes
Yes
10
BEDROOM 3
169 1352 No 1
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
343 ft'
---_
0 1
0
2SIab-On-Grade Edge Insulatio
WIC 1 ft 0
63 fN
___-
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft'
___
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
172 ft'
----
0 1
0
5SIab-On-Grade Edge Insulatio
BATH 5 ft 0
45 ft'
-_--
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 42.6 ft 0
204 ft'
----
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 6.3 It 0
98 ft'
----
0 1
0
4/3/2018
1:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 6
FORM R405-2017
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft'
___
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 48 ft 0
528 ft'
____
0
1
0
10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0
169 ft'
____
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Gable or Shed Metal 1813 ft'
286 ft'
Light
0.6
No
0.9
No
0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1720 ft'
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
343 ft'
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3
tinder Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown
172 ft'
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 ft'
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Wood
7
Under Attic (Vented) ENTRY
30
Blown
98 ft'
0.1
-
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528 ft'
0.1
Wood
10
Under Attic (Vented) BEDROOM 3
30
Blown
169 ft'
0.1.
Wood
WALLS
)rnt
Adjacent Space Cavity Width
TO Vvnil Type
Height
Sheathing Framing
Solar
Below
0
1 N=>SE
Exterior Concrete Block - Ext Ins®EDROOM
4.1 9
0 8
0
72.0 ft'
0
0
0.5
0
2 Si
>NW
Exterior Concrete Block- Ext Insi3EDROOM
4.1 29
0 8
0
232.0 ft'
0
0
0.5
0
3 W=>NE
Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 8
0
112.0 ft'
0
0
0.5
0
4 Si
>NW
Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft°
0
0
0.5
0
5 tJ=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.5
0
6 - NI=>SE
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 14
0 8
0
112.0 ft"
0
0
0.5
0
7 NE=>S
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 2
10 8
0
22.7 ftz
0
0
0.5
0
8 E
>SW
Exterior Concrete Block - 6d InQEDROOM 2
4.1 9
0 8
0
72.0 ft'
0
0
0.5
0
9 SE=>W
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 2
10 8
0
22.7 ft'
0
0
0.5
0
_10 Si>NW
Exterior Concrete Block -Ext InQEDROOM2
4.1 14
0 8
0
112.0 ft'
0
0
0.5
0
11 NE=>S
Exterior Concrete Block - Ext Insul ENTRY
4.1 1
5 8
0
11.3 ft'
0
0
0.6
0
12 E
>SW
Exterior Concrete Block - Ext Insul ENTRY
4.1 5
0 8
0
40.0 ft'
0
0
0.5
0
4/3/2018
1:36 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 3 of 5
FORM R405-2017
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing Solar
Below
13 S=>NW
Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8
0 48.0 ft'
0 0 0.5
0
14
I
Exterior Concrete Block - Ext Irs REAT/DINI 4.1 28 0 8
0 224.0 ft'
0 0 0.5
0
_
INI=>SE
15
=>NE Exterior Concrete Block - Ext Ins REAT/DINI 4.1 20 0 8
0 160.0 ft'
0 0 0.5
0
_ 16
N=>SE Exterior Concrete Block - Ext InfiffDROOM 3 4.1 13 0 8
0 104.0 ft
0 0 0.5
0
_ 17
N=>SE Garage Frame - Wood BEDROOM 3 11 30 8
240.0 ft'
0.23 0.5
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width Height
Area
Ft In Ft In
1 ,E=>SW Insulated ENTRY
None
.39 3
6 8
20 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation Int Shade
Screening
11 W=>NE 3 Metal Low-E Single Yes
0.54 0.25 N
32.4 ft' 1 It 0 in
1 ft 4 in Drapes/blinds
Exterior 5
2 S=>NW 4 Metal Low-E Single Yes
0.54 0.25 N
6.9 ft' 1 ft0 in
1 ft 4 in None
None
3 E=>SW 8 Metal Low-E Single Yes
0.54 0.25 N
23.2 ft' 1 ft 0 in
1 ft 4 in None
None
4 N=>SE 14 Metal Low-E Single Yes
0.54 0.26 N
36.8 ft' 1 ft 0 in
1 ft 4 in None
None
5 W=>NE 15 Metal Low-E Single Yes
0.55 0.25 N
40.0 ft' 10 ft 0 in
1 ft 4 in None
None
6 N=>SE 16 Metal Low-E Single Yes
0.54 0.25 N
16.2 ft' 1 ft 0 in
1 ft 4 in None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 ft' 300 ft'
30 ft
8 ft
11
INFILTRATION
# Sops
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholihouse
Proposed ACH(50) .000356
1605.3 88.13 165.74 .2598
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Duds
1 Electric Heat Pump/ Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit/ Split
SEER: 15 34.8 kBtu/hr
cfm 0.85 1
sys#1
4/3/2018 11:36 AM . EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2017
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal
60.9 gal
120 deg
None
I
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft'
DUCTS
Supply ----
-- Return --
Air
CFM 25
CFM25
HVAC#
#
Locatio--n R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic
6 325 ft'
Attic
85 ft' Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable
Thermostat: Y
Ceiling Fans:
Cooling
Jan
F
r[[[X�]]
[
Jun [[ ]]
[ ]
[ ]
[� ]j
r[X,] Dee
eat ng
Jan
Feb
Mar
Apr
Jun [X] Jul
May
Aug
Sep
L.l
Oct
Nov
Nov
Dec
Venting
lxJ
IXl Jun [[ ]] Jul
EX]
] Aug
EX]
]Sep
ll�xll
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling
AM
78
78
78
78 78 78
78
78
78
78
78
78
iEH)
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
4/3/2018 �11:36 AM
I
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name:' WYNNE THE ROYALE Builder Name: WYNNE
Street: . WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: . FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in an dropped ceiling/soffit /soffit shall be aligned with
y pp g g
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
'
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors i
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
•
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
I
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninino and wirqna
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
ElectricaUphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrinkler cover nlates and walls or ceilmnag
a. In aooltion, Inspection of log walls snail be In accordance with the provisions of ICC-400.
4/3/2018 11:36 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEV., FT. PIERCE, FL,
1. New construction or existing New (From Plans) 9. Wall Types Insulation Area
a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft-
2. Single family or multiple family Single-family b. Frame - Wood, Adjacent R=11.0 240.00 ft-
3. Number of units, if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 3 d. N/A R= ft2
10. Ceiling Types Insulation Area
5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1720.00 ft'
6. Conditioned Floor area (W) 1720 b. N/A R= ft2
7. Windows" Description Area c. DuctR= ff=z
a. U-Factor: ,�• Sgl, U=0.54 115.42 ft' 11 a. Sup: Attic, Ret: Attic, AH: Attic 6 325
SHGF: ' ' SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: ' N/A ft2 13. Heating systems kBtu/hr Efficiency
SHGC: a. Electric Heat Pump 34.8 HSPF:8.50
Area Weighted Average Overhang Depth: 3.316 ft.
Area We Average SHGC: 0.250
8. Floor Types Insulation Area 14. Hot water systems
a. Electric Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2EF: 0.97
b. N/A R= ft2
c. N/A R= R2 b. Conservation features
None
15. Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant f c/
Builder Signature: - Date:
Address Or New Home: City/FL Zip�S� r
This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
e (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
port@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
Rate'ts. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Sion's support staff.
required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8 11:36 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1