HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
WYNNE THE ROYALE IMPACT Builder Name: WYNNE ^t
NF�
Street:
ey
WYNNE DEV. Permit Office: ST. LUCIE COUNTY St�4
City, Stat
, Zip: FT. PI E , FL , Permit Number: L./ a
O ner.
` Q � Jurisdiction: CDu
Design Location:
FL, ort Pierce County:: St. Lucie (Florida Climate Zone 2 ) my
1. New corjstruction or existing New (From Plans)
9. Wall Types (1688.7 sqft.) Insulation Area
2. Single fatmily or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ftz
b. Frame - Wood, Adjacent R=11.0 240.00 ft
3. Number of units, if multiple family 1
c. N/A R= ftz
4. Number of Bedrooms 3
d. N/A R= ftz
10. Ceiling Types (1720.0 sgft.) Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented) R=30.0 1720.00 ftz
6. Conditioned floor area above grade (ftz 1720
b. N/A R= ftz
c. N/A R= ftz
Conditio red floor area below grade (ftz) 0
11. Ducts R ftz
7. Window (155.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 250
a. U-Factor: Sgl, U=0.63 115.42 ftz
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 40.00 ftz
12. Cooling systems kBtu/hr Efficiency
SHG~ : SHGC=0.21
a. Central Unit 34.8 SEER:15.00
C. U-Farrtor: N/A ftz
SHGC:
13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area We Average Overhang Depth: 3.316 ft.
Area Welighted Average SHGC: 0.240
14. Hot water systems
a. Electric Cap: 40 gallons
8. FloorT es (1720.0 sgft.) Insulation Area
W
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ft.
15. Credits Pstat
Glass/FI
0.090 Total Proposed Modified Loads: 55.37 PASS
iorArea:
Total Baseline Loads: 56.24
I hereby ccggrtify that the plans and specifications covered by
Review of the plans and FZ1i8 STq?
this calculation are in compliance with the Florida Energy
specifications covered by this
Cade.
calculation indicates compliance y�ii1.1' = s' ` +`
with the Florida Energy Code. '� nn,,:Xz, ;;:,''.'•°;:••`"„
PREPAR
DATE:
Before construction is completed v
this building will be inspected for
compliance with Section 553.908 * N I' c
I hereby certify that this building, as designed, is in compliance
Florida Statutes. !9�
CeD
with the FlIorida Energy Code.
{yE t¢�
OWNER/A E T:
BUILDING OFFICIAL:
DATE: ` �\
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certifetJ factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope (leakage test report with envelope leakage no greater than 7.00 ACH50 f R402.4.1.2).
,
FILL py Zo,s
4/17/201 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software DEL ® Page 1 of 5
FORM R405-2017
i
I
PROJECT
Title:
WYNNE THE ROYALE IMPA Bedrooms: 3
Address Type:
Street Address
' Building Type:
User Conditioned Area: 1720
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1 Worst Case: Yes
PlatBook:
Builder Name:
WYNNE Rotate Angle: 135
Street:
WYNNE DEV.
Permit O7fice:
ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type:
Single-family
FL,
New/Exis4ing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number
Name Area Volume
1
Entire House 1720 13760
SPACES
Numbelf
Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
BEDROOM 343 2744 No
0
1
1 Yes
Yes
Yes
2
WIC 63 504 No
0
1 No
Yes
Yes
3
M.BATH 56 448 No
0
1 Yes
Yes
Yes
4
KITCHEN 172 1376 Yes
0
1 No
Yes
Yes
5
BATH 45 360 No
0
1 Yes
Yes
Yes
6
BEDROOM 2 204 1632 No
0
1
1 Yes
Yes
Yes
7
ENTRY 98 784 No
0
1 Yes
Yes
Yes
8
LAUNDRY 42 336 No
0
1 Yes
Yes
Yes
9
GREAT/DINING 528 4224 No
0
1 Yes
Yes
Yes
10
BEDROOM 3 169 1352 No
1
1
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
343 ft'
----
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft'
_---
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft°
_---
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
172 ft'
---_
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft'
---_
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0
204 ft'
----
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 6.3 ft 0
98 ft
----
0 1
0
4/17/201
18:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 5
FORM R405-2017
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Woad Carpet
•
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
- -
-
0
1
0
9SIab-On-Grade Edge Insulatio GREAT/DINING 48 ft
0
528 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft
0
169 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Gable or Shed Metal 1813 ft2
286 ft'
Light
0.6
No
0.9
No
0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1720 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
343 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
-
63 ft2
0.1
Wood
3
Under Attic (Vented) M.BATH
30
Blown
56 ft'
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown
172 ft2
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Wood
7
Under Attic (Vented) ENTRY
30
Blown
98 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528 ft2
0.1
Wood
10
Under Attic (Vented) BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Belo w
1 N=>SE
Exterior Concrete Block - Ext Ins®EDROOM
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
2 SI
>NW
Exterior Concrete Block- Ext Ins®EDROOM
4.1 29
0 8
0
232.0 ft2
0
0
0.6
0
3 W=>NE
Exterior Concrete Block - Ext Ins81EOROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
_
4 SI
>NW
Exterior Concrete Block - Ext.InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
5
LSE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
6 N7SE
Exterior Concrete Block - Ext InR&DROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
_ 7 NE=>S
Exterior Concrete Block - Ext InOffDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.5
0
_ 8 EILSW
Exterior Concrete Block - Ext InRffDROOM 2
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
SIE=>W
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.6
0
-9
10 Si
>NW
Exterior Concrete Black - Ext InfiffDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
11 NE=>S
Exterior Concrete Block - Ext Insul ENTRY
4.1 1
5 8
0
11.3 ft2
0
0
0.5
0
_
12 EI
>SW
Exterior Concrete Block - Ext Insul ENTRY
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
4/'17/ Mi
8:47 AM EnergyGauge® USA- FlaRes2017 Section R405.4.1 Compliant Software
Page
3 of 5
rnRnn RenF_�117
_ - --
WALLS
j Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
Space
13 SL>NW Exterior Concrete Block - Ext InsdtAUNDRY 4.1 6 0 8
0 48.0 ft'
0 0 0.5
0
14 N=>SE Exterior Concrete Block - Ext Ins REAT/DINI 4.1 28 0 8
0 224.0 ft'
0 0 0.5
0
_ 15 W=>NE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 20 0 8
0 160.0 ft'
0 0 0.5
0
16 IJ=>SE Exterior Concrete Block - Ext In�DROOM 3 4.1 13 0 8
0 104.0 ft'
0 0 0.5
0
17 NI=>SE Garage Frame - Wood BEDROOM 3 11 30 8
240.0 ft'
0.23 0.5
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width Height
Area
Ft
In Ft In
1 E=>SW Insulated ENTRY
None
.39 3
6 8
20 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
Overhang
V # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation Int Shade
Screening
1 W=>NE 3 Metal Low-E Single Yes
0.63 0.25 N
32.4 ft' 1 it 0 in
1 It 4 in Drapes/blinds
Exterior 5
2 S=>NW 4 Metal Low-E Single Yes
0.63 0.25 N
6.9 ft' 1 it 0 in
1 ft4 in None
None
3 E=>SW 8 Metal Low-E Single Yes
0.63 0.25 N
23.2 ft' 1 ft 0 in
1 It 4 in None
None
4 N=>SE 14 Metal Low-E Single Yes
0.63 0.25 N
36.8 ft' 1 it 0 in
1 It 4 in None
None
51 W=>NE 15 Metal Low-E Single Yes
0.65 0.21 N
40.0 ft' 10 It 0 in
1 It 4 in None
None
6 N=>SE 16 Metal Low-E Single Yes
0.63 0.25 N
16.2 ft' 1 it 0 in
1 ft 4 in None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 ft' 300 ft'
30 It
8 It
11
INFILTRATION
# S Method SLA
CFM 50 ELA EgLA ACH
ACH 50
llpe
1 Wholer ouse Proposed ACH(50) .000356
1605.3 88.13 165.74 .2598
7
I
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit/ Split
SEER: 15 34.8 kStu/hr
cfm 0.85 1
sys#1
4/17/2018 8:47 AM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 4 of 5
Ff1RM Rdr1R-9f117
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft.
DUCTS
--- Supply --
-- Return ---
Air
CFM 25
CFM25
HVAC #
v
# Location
R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic
6 260 ft'
Attic
65 ft' Default.. Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programeble
Thermosta[[tX:]]Y
Cr[eiling Fans:
HeatinDee
g
Jan
[[X]]
Mar
r
Apr
r ]
May ay �X� Jun rl Jul
[ ]
ri Aug
[ ] Sep
j
L J Oct
Nov[[X]][X,]
Nov
Venting
[ ]Feb
[X]
[
Jun [ ]Jul
[)Aug
EX)
1 Sep
lxl
[X]
[ ] Dec
Thermostat!
Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WI)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WI
H)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (Wp)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
2017 -'AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Own r: Jurisdiction:
Design Location: FL, Fort Pierce
I
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors i
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow'cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
9s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nining and w*r no
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/17/2011 8:47 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEV., FT. PIERCE, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior R=4.1
1448.70 ftz
1
b. Frame -Wood, Adjacent
R=11.0
240.00 ft
3. Number of units, if multiple family
1 c. N/A
R=
ft'
4. Number of Bedrooms
3 d. N/A
R=
ft'
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
Yes a. Under Attic (Vented)
R=30.0
1720.00 ft'
6. Conditioned floor area (ft�
1720 b. NIA
R=
ft?
7. Windows'. Description
Area
cDNcts
_
R
z
a. U-Factor: SgI, U=0.63
11
115.42 ft' a. Sup: Attic, Ret: Attic, AH: Attic
R ft
6 250
SHGC: SHGC=0.25
b. U-Factor: SgI, U=0.65
40.00 ft'
SHGC: SHGC=0.21
12. Cooling systems
kBtulhr
Efficiency
c. U-Factor: WA
ff= a. Central Unit
34.8 SEER:15.00
SHGC:
d. U-FaSHdC: r: N/A
13. Heating systems
kBtu/hr
Efficiency
SHGC:
Area Weighted Average Overhang Depth:
a. Electric Heat Pump
3.316 ft.
34.8
HSPF:8.50
Area Weighted Average SHGC:
0.240
8. Floor Types Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft= a. Electric
EF: 0.97
b. N/A R=
ft'
c. N/A R=
ft' b. Conservation features
None
15. Credits
Pstat
I certify th�I t this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on iInstalled Code compliant features.
Builder Signature: Date:
Address of New Home: \p��� City/FL Zip: Ce
This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
e (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
port@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a fist of
Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
sion's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/17 2018 8:47 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1