Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE ^t NF� Street: ey WYNNE DEV. Permit Office: ST. LUCIE COUNTY St�4 City, Stat , Zip: FT. PI E , FL , Permit Number: L./ a O ner. ` Q � Jurisdiction: CDu Design Location: FL, ort Pierce County:: St. Lucie (Florida Climate Zone 2 ) my 1. New corjstruction or existing New (From Plans) 9. Wall Types (1688.7 sqft.) Insulation Area 2. Single fatmily or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ftz b. Frame - Wood, Adjacent R=11.0 240.00 ft 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types (1720.0 sgft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1720.00 ftz 6. Conditioned floor area above grade (ftz 1720 b. N/A R= ftz c. N/A R= ftz Conditio red floor area below grade (ftz) 0 11. Ducts R ftz 7. Window (155.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.63 115.42 ftz SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ftz 12. Cooling systems kBtu/hr Efficiency SHG~ : SHGC=0.21 a. Central Unit 34.8 SEER:15.00 C. U-Farrtor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area We Average Overhang Depth: 3.316 ft. Area Welighted Average SHGC: 0.240 14. Hot water systems a. Electric Cap: 40 gallons 8. FloorT es (1720.0 sgft.) Insulation Area W EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ft. 15. Credits Pstat Glass/FI 0.090 Total Proposed Modified Loads: 55.37 PASS iorArea: Total Baseline Loads: 56.24 I hereby ccggrtify that the plans and specifications covered by Review of the plans and FZ1i8 STq? this calculation are in compliance with the Florida Energy specifications covered by this Cade. calculation indicates compliance y�ii1.1' = s' ` +` with the Florida Energy Code. '� nn,,:Xz, ;;:,''.'•°;:••`"„ PREPAR DATE: Before construction is completed v this building will be inspected for compliance with Section 553.908 * N I' c I hereby certify that this building, as designed, is in compliance Florida Statutes. !9� CeD with the FlIorida Energy Code. {yE t¢� OWNER/A E T: BUILDING OFFICIAL: DATE: ` �\ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certifetJ factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope (leakage test report with envelope leakage no greater than 7.00 ACH50 f R402.4.1.2). , FILL py Zo,s 4/17/201 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software DEL ® Page 1 of 5 FORM R405-2017 i I PROJECT Title: WYNNE THE ROYALE IMPA Bedrooms: 3 Address Type: Street Address ' Building Type: User Conditioned Area: 1720 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV. Permit O7fice: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Exis4ing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1720 13760 SPACES Numbelf Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 343 ft' ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' _--- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft° _--- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft' ---_ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' ---_ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ft' ---- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 6.3 ft 0 98 ft ---- 0 1 0 4/17/201 18:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Woad Carpet • 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 - - - 0 1 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1813 ft2 286 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown - 63 ft2 0.1 Wood 3 Under Attic (Vented) M.BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 98 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 1 N=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 SI >NW Exterior Concrete Block- Ext Ins®EDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.6 0 3 W=>NE Exterior Concrete Block - Ext Ins81EOROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 _ 4 SI >NW Exterior Concrete Block - Ext.InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 5 LSE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 6 N7SE Exterior Concrete Block - Ext InR&DROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 _ 7 NE=>S Exterior Concrete Block - Ext InOffDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0 _ 8 EILSW Exterior Concrete Block - Ext InRffDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 SIE=>W Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.6 0 -9 10 Si >NW Exterior Concrete Black - Ext InfiffDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 11 NE=>S Exterior Concrete Block - Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.5 0 _ 12 EI >SW Exterior Concrete Block - Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 4/'17/ Mi 8:47 AM EnergyGauge® USA- FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 rnRnn RenF_�117 _ - -- WALLS j Adjacent Cavity Width Height Sheathing Framing Solar Below Space 13 SL>NW Exterior Concrete Block - Ext InsdtAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.5 0 14 N=>SE Exterior Concrete Block - Ext Ins REAT/DINI 4.1 28 0 8 0 224.0 ft' 0 0 0.5 0 _ 15 W=>NE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.5 0 16 IJ=>SE Exterior Concrete Block - Ext In�DROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.5 0 17 NI=>SE Garage Frame - Wood BEDROOM 3 11 30 8 240.0 ft' 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft' 1 it 0 in 1 It 4 in Drapes/blinds Exterior 5 2 S=>NW 4 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft' 1 it 0 in 1 ft4 in None None 3 E=>SW 8 Metal Low-E Single Yes 0.63 0.25 N 23.2 ft' 1 ft 0 in 1 It 4 in None None 4 N=>SE 14 Metal Low-E Single Yes 0.63 0.25 N 36.8 ft' 1 it 0 in 1 It 4 in None None 51 W=>NE 15 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft' 10 It 0 in 1 It 4 in None None 6 N=>SE 16 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 it 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 300 ft' 300 ft' 30 It 8 It 11 INFILTRATION # S Method SLA CFM 50 ELA EgLA ACH ACH 50 llpe 1 Wholer ouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7 I HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kStu/hr cfm 0.85 1 sys#1 4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 Ff1RM Rdr1R-9f117 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft. DUCTS --- Supply -- -- Return --- Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 260 ft' Attic 65 ft' Default.. Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programeble Thermosta[[tX:]]Y Cr[eiling Fans: HeatinDee g Jan [[X]] Mar r Apr r ] May ay �X� Jun rl Jul [ ] ri Aug [ ] Sep j L J Oct Nov[[X]][X,] Nov Venting [ ]Feb [X] [ Jun [ ]Jul [)Aug EX) 1 Sep lxl [X] [ ] Dec Thermostat! Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WI) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WI H) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (Wp) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 2017 -'AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Own r: Jurisdiction: Design Location: FL, Fort Pierce I COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors i The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow'cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 9s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nining and w*r no Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/17/2011 8:47 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEV., FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ftz 1 b. Frame -Wood, Adjacent R=11.0 240.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1720.00 ft' 6. Conditioned floor area (ft� 1720 b. NIA R= ft? 7. Windows'. Description Area cDNcts _ R z a. U-Factor: SgI, U=0.63 11 115.42 ft' a. Sup: Attic, Ret: Attic, AH: Attic R ft 6 250 SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.65 40.00 ft' SHGC: SHGC=0.21 12. Cooling systems kBtulhr Efficiency c. U-Factor: WA ff= a. Central Unit 34.8 SEER:15.00 SHGC: d. U-FaSHdC: r: N/A 13. Heating systems kBtu/hr Efficiency SHGC: Area Weighted Average Overhang Depth: a. Electric Heat Pump 3.316 ft. 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.240 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft= a. Electric EF: 0.97 b. N/A R= ft' c. N/A R= ft' b. Conservation features None 15. Credits Pstat I certify th�I t this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on iInstalled Code compliant features. Builder Signature: Date: Address of New Home: \p��� City/FL Zip: Ce This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient e (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at port@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a fist of Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building sion's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17 2018 8:47 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1