Loading...
HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATIONDate Contiactor: _ Job Address: Construction: I Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM RECENED AUG A 5 7019 Permitting Department St. Lucie County House Infiltration Test Certification �' Prescriptive and Performance Method -del ByN�cO Permit #: I S l l - o Mna i�ve'mdrwzn.'r 3 It 4 s' New Construction — Complete ( ) Existing —After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) = 19 S Test Date: 1 31 I ( 9 volume = I I S 6 8 ACH (50) = CFM (50) x 60 / Volume = S �% Me hanical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less (Pass ( ) Fail FBC, Energy ` The btjiiding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower, door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an appro�ed third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential , Where Ithe air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testin Comoanv Company Name: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949 I here biy certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signat re: 17U� Printed Name: Martin Klein Licens/Certification #: 5061633 I BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road, Suite 210 " 7-7 '' Malta, NY 12020.` (877) 274-1274- www.bpi.org 4f� Martin Klein 5 BPI BPI IDR: 50616?- a , CERTIFIED PROFESSIONAL ws.i °M (4EE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES)