HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM' R405-2017
FLO�IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE ROYALE IMPACT
Builder Name: WYNNE
SCANNED
Street: WYNNEDEV.
Permit Office: ST. LUCIE COUNTY
BY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
S t
Owner. �?j�`�j� CD �\ UfN
Jurisdiction:
Lucie County
Design Location: FL, Fort Pierce
I
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1688.7 sqft.)
Insulation Area
2. Single i'amily or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1448.70 ft°
b. Frame - Wood, Adjacent
R=11.0 240.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 3
d. N/A
R= ft'
5. Is this a worst case? Yes
10. Ceiling Types (1720.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1720.00 ft'
6. Condit toned floor area above grade (ft') 1720
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(155.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor. Sgl, U=0.63 115.42 ft'
SHGC: SHGC=0.25
b. U-Factor. Sgl, U=0.65 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft'
'
SHGC:
13. Healing systems
kBtu/hr Efficiency
d. U-Factor. N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.240
14. Hot water systems
8. Floor Types (1720.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Patel
Total Proposed Modified Loads: 55.37
Glass/Floor Area: 0.090
PASS
Total Baseline Loads: 56.24
1 hereby (certify that the plans and specifications covered by
Review of the plans and
THE Sr9?F
this calculation are in compliance with the Florida Energy
specifications covered by this
Of
y = - , O
Code.
calculation indicates compliance
°a
with the Florida Energy Code:
nnu+. •Cj .°„„, O
PREPA R1 �rD BY:
DATE: 1 �1
Before construction is completed
this building will be inspected for
compliance with Section 553.908
v
0
R o
I hereby
with the
certify that this building, as designed, is in compliance
Florida Energy Code.
Florida Statutes.
G'Op {RV
OWNEFfAG
ENT-
BUILDING OFFICIAL:
WE
DATE:\\Lt
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FI�vC Ir® Pla
' oE� oa g
4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
I
Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE ROYALE IMPA Bedrooms: 3
Address Type:
Street Address
BuildinglType: User
Conditioned Area: 1720
Lot#
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE
Rotate Angle: 135
Street:
WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.6 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1720 13760
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM
343 2744 No
0
1
1 Yes
Yes
Yes
2 WIC
63 604 No
0
1 No
Yes
Yes
3 M.BATH
56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN
172 1376 Yes
0
1 No
Yes
Yes
5 BATH
45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY
98 784 No
0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
528 4224 No
0
1 Yes
Yes
Yes
10 BEDROOM 3
169 1352 No
1
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
_ 1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
343 ft'
___
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft'
-_
0 1
0
3SIab-On-Grade Edge Insulatio
M. BATH 8 It 0
56 ft'
____
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
172 ft'
—
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft'
____
0 1
0
i
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 42.6 ft 0
204 ft'
—
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 6.3 It 0
98 ft'
____
0 1
0
4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
# .
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft'
___
0
1
0
9SIab-On-Grade Edge Insulatio GREAT/DINING 48 ft 0
528 ft'
__
0
1
0
_
10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0
I
169 ft'
____
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Gable or Shed Metal 1813 It'
286 ft'
Light
0.6
No
0.9
No
0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1720 ft'
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
343 ft'
0.1
Wood
_
2
Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
3
Under Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown
172 ft'
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 ft'
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Wood
7
Under Attic (Vented) ENTRY
30
Blown
98 ft'
0.1
Wood
_
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528 ft'
0.1
Wood
10
Under Attic (Vented) BEDROOM 3
30
Blown
169 ft'
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Below
0
_ 1
I N=>SE
Exterior Concrete Block - Ext Ins®EDROOM
4.1 9
0 8
0
72.0 ft'
0
0
0.5
0
2
IS=>NW
Exterior Concrete Block - Ext Ins®EDROOM
4.1 29
0 8
0
232.0 ft'
0
0
0.5
0
3
W=>NE
Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 8
0
112.0 ft'
0
0
0.5
0
_ 4
IS=>NW
Exterior Concrete Block- Ext InsuM. BATH
4.1 8
0 8-
0
64.0 ft'
0
0
0.5
0
5
' N=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.5
0
6
' N=>SE
Exterior Concrete Block - Ext InSEDROOM 2
4.1 14
0 8
0
112.0 ft'
0
0
0.5
0
7
I NE=>S
Exterior Concrete Block - Ext IndIffDROOM 2
4.1 2
10 8
0
22.7 ft'
0
0
0.5
0
_ 8
iE=>SW
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 9
0 8
0
72.0 ft'
0
0
0.5
0
_9
'SE=>W
Exterior Concrete Block -Ext lnQEDROOM2
4.1 2
10 8
0
22.7 ft'
0
0
0.5
0
10
S=>NW
Exterior Concrete Block - Ext InSffDROOM 2
4.1 14
0 8
0
112.0 ft'
0
0
0.5
0
11
1 NE=>S
Exterior Concrete Block - Ext Insul ENTRY
4.1 1
5 8
0
11.3 ft'
0
0
0.5
0
_12
IE=>SW
Exterior Concrete Block -Ext Insul ENTRY
4.1 5
0 8
0
40.0 ft'
0
0
0.5
0
4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
P('1RM RAnr-9f117
WALLS
• Adjacent To 1A1,11 TypeSpace
Cavity Width Height
Sheathing Framing Solar
Below
13 S=>NW Exterior Concrete Block -Ext lnsdlAUNDRY 4.1 6 0 8
_ 14 N=>SE Exterior Concrete Block - Ext Ins3REAT/DINI 4.1 28 0 8
_ 15 W=>NE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 20 0 8
_ 16 N=>SE Exterior Concrete Block - Ext IndaEDR00M 3 4.1 13 0 8
17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8
0 48.0 ft'
0 224.0 ft'
0 160.0 ft'
0 104.0 ft°
240.0 ft'
0 0 0.5
0 0 0.5
0 0 0.5
0 0 0.5
0.23 0.5
0
0
0
0
0
DOORS
# Ornt Door Type
Space Storms
U-Value
Ft
Width Height
In Ft In
Area
1 E=>SW Insulated
ENTRY None
.39 3
6 8
20ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
# Omt ID Frame Panes
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1 W=>NE 3 Metal Low-E Single
_ 2 S=>NW 4 Metal Low-E Single
3 E=>SW 8 Metal Low-E Single
4 N=>SE 14 Metal Low-E Single
5 W=>NE 15 Metal Low-E Single
6 N=>SE 16 Metal Low-E Single
Yes 0.63 0.25 N
Yes 0.63 0.25 N
Yes 0.63 0.25 N
Yes 0.63 0.25 N
Yes 0.65 0.21 N
Yes 0.63 0.25 N
32.4 ft' 1 ft 0 in
6.9 ft' 1 It 0 in
23.2 ft' 1 It 0 in
36.8 ft' 1 ft 0 in
40.0 ft' 10 ft 0 in
16.2 ft' 1 It 0 in
1 It 4 in Drapes/blinds
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
Exterior 5
None
None
None
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 ft' 300 ft' 30 It
8 It
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Who lehouse Proposed ACH(50) .000356
1605.3 88.13 165.74 .2598
7
HEATING SYSTEM
# System Type
Subtype Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split SEER: 15 34.8 kBtu/hr
cfm 0.85 1
sys#1
4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
HOT WATER SYSTEM
! # . System Type
SubType
Location
EF Cap Use
SeWnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart #
Company Name
System Model # Collector Model
# Area
Volume
FEF
_ None
None
ft'
DUCTS
-- Supply --
— Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
_ 1
Attic
6 250 ft'
Attic
65 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Program able Y
Ceiling Fans:
jThermostar[t:
HeatnOct
g (X] Jan
Feb
r[ ]]
[X] Mar
[ ]
[ ]
Apr [
rr ]] [[
[X] Jun [X� Jul
r[[ ]]
Aug
[ ]
Sep
[ j]
E ]
W
OctNov
Nov
Dec
Venting [ 1 Jan
[ Feb
l
[[Xl Mar
[X]
I
May II 1 Jun [ Jul
I Aug
LXl
EX]
) Sep
Dec
Thermostat Schedule:
HERS 2005 Reference
Hours
SchedulelType
1
2
3
4 5. 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (IND)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
1
PM
68
68
68
68 68 68
68
68
68
68
66
66
i
4/17/2018 8:47 AM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninono and wirmno
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVACI, register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrinkler cover nlates and walls or cemlonas
a. In aaanlon, Inspection Or log Walls shall be In accordance with the provisions of IC"00.
4/17/2018 8:47 AM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New cclppInstruction or existing
2. Singlefamily or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this'a worst case?
6. Conditioned floor area (ft�
7. Windows" Description
a. U-Factor. Sgl, U=0.63
SHGC: SHGC=0.25
b. U-Factor. Sgl, U=0.65
SHGC: SHGC=0.21
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A,I
c. N/A
WYNNE DEV., FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1448.70 ft'
b. Frame - Wood, Adjacent
R=11.0
240.00 ft
1
c. WA
R=
ft'
3
d. N/A
R=
ft'
Yes
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1720.00 ft'
1720
b. N/A
R=
ft'
Area
c. N/A
R=
ft'
115.42 ft'
11. Duds
R ft
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
40.00 ft'
12. Cooling systems
kBtu/hr
Efficiency
ft'
a. Central Unit
34.8
SEER:15.00
ft'
13. Heating systems
kBtulhr
Efficiency
a. Electric Heat Pump
34.8
HSPF:8.50
3.316 ft.
0.240
Insulation
Area
14. Hot water systems
Cap:
40 gallons
R=0.0
1720.00 ft'
a. Electric
EF: 0.97
R=
ft'
R=
ft'
b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on' installed Code compliant features. Builder Signature: �- Date: \i'\ \t-4k G p
Address of New Home:\"j Sis Cj ����� City/FL Zip:
- -2:1
This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
le (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
port@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Ision's support staff.
required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/17/2018 8:47 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1