r FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
,FORM-•60OA-93 Residential Whole Building Performance Method A
PROJECT NAME: CUSTOM :BUILDER:
SN: blly
SOUTH
AND ADDRESS: LAPI RESIDENCE :PERMITTING :CLIMATE
j LOT"- 10 II :OFFICE: ' :ZONE: 7:_: 8:_: 9:
+ OWNER: ti :PERMIT NO. :JURISDICTION NO.
1. New construction or addition
i.2. Single family detached or Multifamily attached
3. If Multifamily -No. of units
4. if Multifamily, is this a worst case (yes/no)
5. Conditioned floor area (sq.ft.)
6. Predominant eave overhang (ft.)
7. Porch overhang length (ft.)
8. Glass area and type:
a. Clear lass
'b. Tint, film or solar screen
9. Floor type and insulation:
i b. Wood, ,raised (,R-value, area )
C 10.Net Wall' type area and insulation:
1. New Construction _
2. Single -Family _
3. 0 _
4. _
5. 1024.00 _
6. 0.20 _
7. 0.00 _
Single Pane Double Pane
8a.114.Osgft 7.00sgft _
8b. O.Osgft O.00sgft _
9b.R=11.00 , 1024.00 sgft
CK
a. Exterior: 2. Wood frame (Insulation R-value) 10a-2 R=11.00, 1113.00sgft_
11.Ceiling'type area and insulation:
a. Under attic (Insulation R-value)
12'.Air distribution systems
a. Ducts (Insulation + Location)
13.Cooling system
%4.Heating System:
15.Hot water system:
16.Hot Water Credits: (HR-Heat Recovery,
DHP-Dedicated Heat Pump)
17.Infiltr tion practice: 1, 2 or 3
18.HVAC Ctits (CF-Ceiling Fan, CV -Cross vent,
N-Whole,. house fan, RB-Attic radiant
barrier, MZ=Multizone)
19.EPI (must not exceed 100 points)
a. Total As -Built points
b. Total Base points
--------------------------------------
I Hereby certify that the plans and
,specifications covered by this calcu-
latibn arelin compliance with the
a Florida Energy Code.
PREPARED B :
DATE:
0
I hereby certify that this building is
i
n
with-the Florida
Energy -de. II'
t: tiv
TE:
11a.R=30.00 , 1024.00sgft
12a. R= 6.00 , uncond
13. Type: Central. A/C
SEER: 12.00
14. Type: Strip Heat
COP: 1.00
15. Type: Electric
EF: 0.90
16.
17. 2
18.
19. 99.78
19a. 20094.68
19b. 20138.61
--------------------------------------
Review of the plans ,and specifications
covered by this calculation indicates
compliance with the Florida Energy
Code. Before construction is completed
this building will be inspected for
compliance in accordance with Section
553.908 F.S.
BUILDING OFFICIAL:
DATE:
Kk iNKILTRATION REDUCIION PRACTICE COMPLIANCE CHECKLIST �*
COMPONENTS - -SECTION__
REQUIREMENTS -FOR vEACH -PRACTICE CHECK
PRACTICE #11------606.1
INFILTRATION PRESCRIPTIVES.
------------s
t, Window
606.1
--COMPLY-WITH-ALL
--------------------------------------
Maximum of 0.34 CFM per linear foot of operable sash
crack (includes sliding glass doors).
-------------------------------------------------------------------------------
Exterior &
606.1
Maximum of 0.5 CFM per sq. ft. of door area: solid
' Adjacent Doors
core, wood panel,insulated or glass doors only.
-------------------------------------------------------------------------------
Exterior Joints
606.1
To be caulked, gasketed, weather-stripped or other-
& Cracks
wise sealed:
-------------------------------------------------------------------------------
PRACTICE #2I
606.1
COMPLY WITH PRACTICE #1 AND THE FOLLOWING:
-----------J--------------------------------------------------------------------
Exterior Walls
606.1
Top plate penetrations sealed. Infiltration barrier
& Floors
installed. Sole plate/floor joint caulked or sealed.
---------
Exterior Walls
----------------------------------------------------------
606.1
Penetrations, joints and cracks on interior surface
& Ceilings
caulked, sealed or gasketed.
=-------------------------------------------------------------------------------
•DuctWork
606.1
Ductwork in unconditioned space must be sealed.
-----------------
Fireplaces
---------------------------------------------------------
606.1
Equipped with outside combustion air, doors and flue
.
dampers.
-----------1-------------------------------------------------------------------
exhaust Fans
606.1
Equipped with dampers. Combustion devices see
606.1.A.2.
-----------=------=------------------------------------------------------------
Combustion
606.1
Combustion space and water heating systems provided
1 Heating
with outside combustion air, except direct vent
appliances.
-------------------------------------------------------------------------------
** OTHER PRESCRIPTIVE
4--------------------------------------------------------------------
MEASURES (must be met or exceeded by all residences.)*
-----------
Water Heaters
612.1
Comply with efficiency requirements in Table 6-11.
Switch or clearly marked circuit breaker (electric)
or cutoff (gas) must be provided. External or built-
in heat trap required.
-------- —-----------------------------------------------------------------
---
Swimming Pools
612.1
Spas and heated pools must have covers (except solar
_ & Spas
heated). Non-commercial pools must have a pump timer.
Gas spa & pool heaters must have a minimum thermal
efficiency of 78 percent.
----------- --------------------------------------------------------------------
' Shower Heads
612.1
Water flow must be restricted to no more than 3 gal -
Ions per minute at 80 PSIG.
-------------------------------------------------------------------------------
i
Air Distribution
610.1
All ducts, fittings, mechanical equipment and plenum
Systems
chambers shall be mechanically attached, sealed, ins-
ulated and installed in accordance with the criteria
of Section 610. Ducts in unconditioned attics must
be insulated to a minimum of R-6. Air handlers shall
not be installed in attics unless in mechanical
l
closet.
------------------------------------------------------------
HVAC Contro
s
607.1
-------- ------- ---
Separate readily accessible manual or automatic
----------
thermostat for each system.
-------------
Insulation
---------------------------------------------------------
604.1
Ceilings minimum R-19. Common Walls - Frame R-11 or
--------------------------------------------------------------------------------
602.1
CBS R-3 both sides. Common ceiling & floors R-11.
i
SUMMER CALCULATIONS
--= BASE _-=
--------------------
i
-_= AS -BUILT
GLASS ----------------
ORIEN AREA x B,SPM =
POINTS ;
TYPE
SC ORIEN AREA
x SPM x
SOF
= POINTS
-------------------------------------------------------------------------------
NE 7.00, 109.7
767.9
DBL CLR
NE 7.0
88.0
.98
601.3
E 36.00: 109.7
4168.6 i
SGL CLR
E 38.0
136.3
.99
5125.4
SW 12.00 109.7
1316.4 i
SGL CLR
SW 12.0
146.2
.99
1738.2
W 64.00 109.7
7020.8 i
SGL CLR
W 64.0
136.3
.99
8619.4
-------------------------------------------------------------------------------
.15 x COND. FLOOR / TOTAL GLASS
= ADJ.
x GLASS -
ADJ GLASS
i
GLASS
AR A
AREA
FACTOR
POINTS
POINTS
i
POINTS
-----------I -----------------------------------------------------------------
15 1,024�00
1.269
13,273.70
16,849.92
i
16,064.29
----121_00---
NON GLASS -- ---------
AREA x BSPM =
POINTS i
TYPE
R--VALUE
AREA x
SPM
= POINTS
--------------------------------------------------------------------------------
WALLS----------------
Ext 1113.0 1.6
1780.8 ;
Ext Wood
Frame 11.0
1113.0
2.70
3005.1
DOORS ----------------
Ext 24.0 6.4 153.6
CEILINGS --- I---------
UA 1024.OI .8 819.2
FLOORS ---------------
wRsd 1024.0 -2.2-2211.8
Ext Wood 24.0 9.40 225.6
Under Attic 30.0 1024.0 .80 819.2
Rsd Wood Adjacent 11.0 1024.0 1.00 1024.0
INFILTRATION---------
i
14.7 15052.8
i Practice
#2
1024.0
14.70
15052.8
-----1024_OI-
-------------------------
TOTAL SUMMER POINTS
i
32,444.48
3
6,210.99
TOTAL x SYSTEM = COOLING
i TOTAL x
CAP x DUCT x
SYSTEM x
CREDIT
= COOLING
SUM PTS MULT POINTS
COMPON
RATIO MULT
MULT
MULT
POINTS
---------------------- 7--------------------------------------------------------
32,444.48 .37 12,004.46
; 36,210.99
1.00 1.070
.280
1.000
10,848.81
*a:%K*%ii%K�:WWx:*W%K�:W:i:%Kx:%kW:K***%�=�:WWW�:x:.w�:**%K.�W*�:x:.x'-�:isy:�:%�:%�:%r-:�%r.*h:�:xx:x:�:�:%�:%K�:�:x-•a::{:�:%r.�:a,%rx:.{:*�:*�:W�:
WINTER CALCULATIONS
BASE __=
=-= AS -BUILT
GLASS ------=---------
i
_ ORIEN AREAIx BWPM =
POINTS ;
TYPE-
SC ORIEN AREA x WPM x
WOF =
POINTS
------------------------------------------------
NE 7.00 -.4
-2.8 i
DBL CLR
NE 7.0 1.4
1.04
10.2
E 38.00 -.4
-15.2
SGL CLR
E 38.0 .l
1.22
4.6
SW 12.00 -.4
-4.8 i
SGL CLR
SW 12.0 -2.1
.98
-24.8
W 64.00 -.4
-25.6 i
SGL CLR
W 64.0 .1
1.25
8.0
------------------------------------------------=------------------------------
15 x COND.�FLOOR / TOTAL GLASS
= ADJ.
x GLASS = ADJ GLASS
;
GLASS
AR A
AREA
FACTOR
POINTS POINTS
;
POINTS
----------- -------------------------------------------------------------------
.15 1,024100-------121_00
1.269
-48.40 -61.44
;
-2.00
NON GLASS------------
i
AREA 'x BWPM =
- ------------------------------------------------------------------------------
POINTS ;
TYPE
R-VALUE AREA x
WPM
= POINTS
I WALLS ------------ ----
Ext 1113.0 .3 333.9
DOORS ----------------
Ext 24.0 1.8 43.2
CEILINGS --------------
,UA 1024.01 .1 102.4
FLOORS ---------------
.Rsd 1024.0' -.3 _286.7
INFILTRATION---------
Ext Wood Frame
Ext Wood
Under Attic
Rsd Wood Adjacent
11".0 1113.0
.60
667.8
24.0
2.80
67.2
30.0 1024.0
.10
102.4
11.0 1024.0
.50
512.0
__---1024_0j- 1.2
1228.8
; Practice #2
1024.0 1.20
1228.8
TOTAL WINTER POINTS
,1,360.14
;
2,576.20
-
TOTAL x SYSTEM =
HEATING
------------------------------------
i TOTAL- x CAP x DUCT
x SYSTEM x CREDIT
= HEATING
WIN PTS MULT
POINTS
i COMPON RATIO MULT
MULT MULT
POINTS
-------------------------------------------------------------------------------
1,360.14 1.10 1,496.15 i 2,576.20 1.00 1.070 1.000 1.000 2,756.54
L-===____
i
A.F %hT n..b m-h m •bn:m T,h.h.h x; A�%h T%hTTT,h,P.h m.b A: X-•h -0•T mmm:f-d-.t, m m.n... n. m .r a. n..n m,l.,t•,n.P m.n T n.,r n.,n a. ,n.n.n a, n, n.T n,m m,e, n, mq,.b n-
! WATER HEATING
BASE __= i =_= AS -BUILT =_-
---------------------------
----
NUM OF x MULT = TOTAL TANK VOLUME EF TANK x MULT x CREDIT TOTAL
BEDRMS - RATIO MULT
------------------------------------------------------------------------------
2 3319.0 6,638.00 t 50 .90 1.000 3244.7 1.00 6,489.33
SUMMARY
BASE ___ ------------------AS_BUILT-------------
COOLING HEATING HOT WATER TOTAL i COOLING HEATING HOT WATER TOTAL
POINTS + POINTS + POINTS = POINTS ; POINTS + POINTS + POINTS POINTS
-----------
7-------------------------------------------------------------------
12004.5 1496.2 6638.0 20,138.61 i 10848.8 2756.5 6489.3 20,094.68
i x<x<x<x:xcx:xcxcx:x:x:***x:x:x:
I• =K EPI = 99.78 x;
i I
tIVtRCiY GU1Ut
!.For detai,led information
of the EPI rating number
or for any ITEM listed,
ask your Builder for EPI= 99.8
DCA Form 600A-93
' or Form 600E-93
0 10 20 30 40 50 60 70 80 90 100
--------------------------------------- X-
The maximum allowable EPI is 100. The lower the EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM HOME VALUE
1
WINDOWS .....................Single Clear
(.INSULATION ..................
Ceiling R-Value......... 30.0
I
Wall R-Value......... 11.0
Floor R-Value......... 11.0
AIR CONDITIONER .............
SEER ...................... 12.0
'HEATING SYSTEM ..............
Electric COP ............. 1.0
WATER HEATER.( ...............
I
i
Electric EF.............. 0.90
Gas EF.............. 0.00
:Solar EF..............
Low Efficiency
SINGL CLR
X-----
High Efficiency
DBL TINT
R-10 R-30
--------------------X
R-0 R-7
--------------------Xi
R-O R-19
----------- X---------
10.0 SEER 17.0
'----- X---------------
2.50 COP 4.19
X--------------------
0.88 0.96
---- X----------------
0.54 0.90
0.40 0.80
OTHER FEATURES ..............
.............I..............
II certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
Address:
Builder
Signature:
City/Zip
Florida Energy Code for Building Construction - 1993
Florida Department of Community Affairs
te:
FL-EPL CARD93
I
' tIV CFfhY UUlUt
For detailed information
of th6 EPI rating number
or for any ITEM listed,
ask your Builder for EPI= 99.8
DCA Form 60OA-93
or Form 60OB-93,
0 10 20 30 40 50 60 70 80 90 100
i
--------------------------------------X-
The maximum allowable EPI is 100. The lower the EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
1 ITEM
HOME VALUE
WINDOWS.....(................Single Clear
INSULATION ..................
Ceiling R-Value......... 30.0
C
Wall R-Value......... 11.0
Floor R-Value......... 11.0
Low Efficiency High Efficiency
SINGL CLR DBL TINT
X--------------------
R-10 R-30
--------------------Xi
R-0 R-7
'-------------------- X,
R-0 R-19
----------- X---------
JAIR CONDITIONER .............
10.0 SEER
;. SEER ......................
12.0
i----- X---------- ---17.0
HEATING SYSTEM— .....
2.50 COP 4.19
Electric COP .............
1.0
:X --------------------
iWATER HEATER.( ...............
0.88 0.96
Electric EF..............
0.90
;---- X----------------
0.54 0.90
Gas EF..............
0.00
;---------------------
0.40 0.80
Solar EF..............
;---------------------
OTHER FEATURES ...............
I
i...........................
I certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
Builder
Address: Signature:
City/Zip
Florida Energy Code for Building Construction - 1993
Florida Department of Community Affairs
te:
FL-EPL CARD93
I
l',
1
RESIDENTIAL COOLING
& HEATING LOAD
ACCA - MANUAL
"J"
I' PROJECT:LAPI
RESIDENCE
MODEL:
CUSTOM
------------------------------------------------------------------
O.A.
TEMP
GRAINS
DESIGN
TEMP DIFF:
16
INDOOR:
75
73
AIR CHANGES:
0.3
OUTDOOR:
91
128
GLASS TYPE:
DELTA:
16
55
--SYSTEM
#1--
--SYSTEM
#2---
CEIL
FLOOR
CEIL
FLOOR
HEIGHT
AREA
HEIGHT
------
AREA
------
�COOLING
LOAD:
------
10
------
1,024
1
SHADED
--ENTIRE
HOUSE-
--SYSTEM
#1--
--SYSTEM
#2---
WINDOW
AREA
HTM
[SQ FT]
[BTUH].
------
[SQ FT]
------
[BTUH]
------
[SO FT]
------
[BTUH]
------
--------
N TINT
----
0%
------
20
------
0
0
0
0
NE TINT
0%
43
7
301
7
301
0
E TINT
0%
61
38
2,318
38
2,318
0
SE TINT
0%
53
0
0
0
0
S TINT
0%
32
0
0
0
0
SW TINT
0%
53
12
636
12
636
0
W TINT
0%
61
64
3,904
64
3,904
0
NW TINT
i
0%
43
0
0
0
0
N CLEAR
0%
27
0
0
0
0
NE CLEAR
0%
60
0
0
0
0
E CLEAR
0%
85
0
0
0
0
SE CLEAR
0%
74
0
0
0
0
S CLEAR
0%
44
0
0
0
0
SW CLEAR
1
0%
74
0
0
0
0
W CLEAR
0%
85
0
0
0
0
NW CLEAR
0%
60
0
0
0
0
N BLINDS
0%
16
0
0
0
0
E BLINDS
0%
46
0
0
0
0
S BLINDS
0%
25
0
0
0
0
W BLINDS
0%
46
0
0
0
0
PORCHES
0%
27
0
0
0
0
HORZi
0%
116
0
0
0
0
--ENTIRE HOUSE- --SYSTEM #1-- --SYSTEM #2---
[SO FT] [BTUH] [SQ FT] [BTUH] [SQ FT] [BTUH]
------ ------ ------ ------ ------ ------
GLASS SUBTOTAL 121 7,159 121 7,159 0 0
--ENTIRE HOUSE- --SYSTEM #1-- --SYSTEM #2---
DOOR HTM [SQ FT] [BTUH] [SQ FT] [BTUH] [SQ FT] [BTUH]
------------- ------ ------ ------ ------ ------ ------ ------
SOLID WOOD 9 24 209 24 209 0
METAL 9 0 0 0 0
OUTSIDE WALL HTM [SQ FT] [BTUH] [SQ FT] [BTUH] [SO FT] [BTUH]
------------- ------ ------ ------ ------ ------ ------ ------
FRAME/wR-11/D 1.70 1,113 1,892 1,113 1,892 0
BLOCK/wR-4.2 1.60 0 0 0 0
0 0 0 0
PARTITION HTM [SQ FT] [BTUH] [SO FT] [BTUH] [SO FT] [BTUH]
------------- ------ ------ ------ ------ ------ ------ ------
Frame/wR-11/D 0.90 0 0 0 0
BLOCK/wR-4.2 0.50 0 0 0 0
ROOF/wCEILING HTM [SQ FT] [BTUH] [SQ FT] [BTUH] [SO FT] [BTUH]
------------- ------ ------ ------ ------ ------ ------ ------
Attic/wR-19 2.10 0 0 0 0
Attic/wR-30 1.30 1,024 1,331 1,024 1,331 0
FLOOR , HTM [SO FT] [BTUH] [SQ FT] [BTUH] [SQ FT] [BTUH]
------------- ------ ------ ------ ------ ------ ------ ------
Abv Garage/11 0.80 1,024 819 1,024 819 0
Slab Perimeter 0 0 0 0
MISCL. ITEM HTM [QTY] [BTUH] [QTY] [BTUH] [QTY] [BTUH]
------------- ------ ------ ------ ------ ------ ------ ------
People 300 4 1,200 4 1,200 0
Lites & Appl 0 0 1,200 1,200 0
Infl/Vent'n 17 51 887 51 887 0 0
Other 0 0 0 0 0
------------------------
SENS BTUH SUBTOTAL 14697 20223 0
10% DUCT HEAT GAIN 1470 2022 0
------------------------
TOTAL SENSIBLE LOAD 16166 22245 0
rl
16 DEG DT CFM REQUIRED
936
1287
0
LATENT LOAD
LOAD --ENTIRE
HOUSE-
--SYSTEM #1--
--SYSTEM
#2---
FACTOR QTY
BTUH
-------
QTY BTUH
-------------
QTY
------ --------
BTUH
------------- ------ ------
People 230 4
920
4 920
0
0
Appliances 0
800
800
0
Infl/Vent'n 51
1,918
51 1,918
0
0
Other, 0 0
0
0
-------
LATENT BTUH SUBTOT:
3,638
--------
3,638
-------
0
2% DUCT LEAKAGE:
--------
963
963
--------
--------
0
TOTAL LATENT LOAD:
•I
4,601
4,601
0
SENS HEAT RATIO:----78%-
ERR
GRANDTOTAL COOLING LOAD:
20,767
----83%-
26,846
0
jHEATING LOAD:
--ENTIRE
HOUSE-
--SYSTEM #1--
--SYSTEM #2---
GLASS
HTM
[SQ FT]
[BTUH]
[SQ FT]
[BTUH]
[SO
FT]
[BTUH]
GLASS
35
121
4,199
121
4,199
0
0
--ENTIRE
HOUSE-
--SYSTEM #1--
--SYSTEM
#2---
DOOR
HTM
[SO FT]
------
[BTUH]
------
[SO FT]
------
[BTUH]
------
[SQ
------
FT]
[BTUH]
------
-------------
SOLID WOOD
------
14
24
331
24
331
0
0
METAL
14
0
0
0
0
0
0
OUTSIDE WALL
HTM
[SO FT]
[BTUH]
[SQ FT]
[BTUH]
[SQ
FT]
[BTUH]
-------------
FRAME/wR-11/D
------
2.70
------
1,113
------
3,005
------
1,113
------
3,005
------
O
------
0
BLOCK/wR-4.2
4.30
0
0
0
0
0
O
1
O
O
0
0
0
0
PARTITION
HTM
[SO FT]
[BTUH]
[SO FT]
[BTUH]
[SQ
FT]
[BTUH]
Frame/wR-11/D
2.70
0
0
0
0
0
0
BLOCK/wR-4.2
4.30
0
0
0
0
0
0
ROOF/wCEILING
HTM
[SO FT]
[BTUH]
[SO FT]
[BTUH]
[SO
FT]
[BTUH]
-------------
Attic/wR-19
------
1.60
------
0
------
0
------
0
------
0
------
0
------
0
Attic/wR-30
1.00
1,024
1,024
1,024
1,024
0
0
FLOOR I
HTM
[SQ FT]
[BTUH]
[SO FT]
[BTUH]
[SQ
FT]
[BTUH]
------------- ------
Abv Garage/11 2.10
------
1,024
------
2,150
------
1,024
------
2,150
------
0
------
0
Perimeter 24.30
0
0
0
0
0
0
I INFIL & VENT HTM
[CFM]
------
[BTUH]
------
[CFM]
------
[BTUH]
------
[CFM]
------
[BTUH]
------
------------- ------
VENT 30.00
51
1,539
51
1,539
0
0
INFIL 30.00
85
2,541
85
2,541
0
0
HEATING SUBTOTAL:
14,789
14789
0
10% DUCT HEAT
GAIN:
1,479
1479
0
--------
--------
--------
TOTAL HEATING
LOAD:
16,268
16268
0
HEATING LOAD
[KW]:
5
5
0
I �
►
q63 < O.M.B. NO. 3067-0077, �q`g�Do
ELEVATION CERTIFICATEExpirmMay31,1996
FEDERAL EMERGENCY MANAGEMENT AGENCY
NATIONAL FLOOD INSURANCE PROGRAM
ATTENTION: Use of this certificate does not provide a waiver of the flood insurance purchase requirement. This form is used only to
provide elevation information necessary to ensure compliance with applicable community floodplain management ordinances, to
determine the proper insurance premium rate, and/or to support a request for a Letter of Map Amendment or Revision (LOMA or LOMR).
Instructions for completing this form can be found on the following pages.
SECTION A PROPERTY INFORMATION I FOR INSURANCE COMPANY USE I
OWNER'S NAME
STREET ADDRESS (Including Apt., Unit, Suite and/or Bldg. Number) OR P.O. ROUTE AND BOX NUMBER
DESCRIPTION (Lot and Block Numbers, etc.)
POLICY NUMBER
COMPANY NAIC NUMBER
ITV STATE ZIP CODE
Jensen Beach Florida 34957
SECTION B FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
ovide the following from the proper FIRM (See Instructions):
1. COMMUNITY NUMBER
2. PANEL NUMBER
3. SUFFIX
4. DATE OF FIRM INDEX
5. FIRM ZONE
6. BASE FLOOD ELEVATION
(in AO Zones, use depth)
120285
0311
F
8-19-91
AE
8'
7. Indicate the elevation datum system used on the FIRM for Base Flood Elevations (BFE): ® NGVD '29 ❑ Other (describe on back)
8. For Zones A or V, where no BFE is provided on the FIRM, and the community has established a BFE for this building site, indicate
the community's BFE: III . —I feet NGVD (or other FIRM datum -see Section B, Item 7).
SECTION C BUILDING ELEVATION INFORMATION
1. Using the Elevation Certificate Instructions, indicate the diagram number from the diagrams found on Pages 5 and 6 that best
describes the subject building's reference level 7 .
2(a)� FIRM Zones A1-A30, AE, AH, and A (with BFE). The top of the reference level floor from the selected diagram is at an elevation
lof I 1 1 111- I$U feet NGVD (or other FIRM datum -see Section B, Item 7).
(b).,FIRM Zones V1430, VE, and V (with BFE). The bottom of the lowest horizontal structural member of the reference level from
the selected diagram, is at an elevation of ICJ .0 feet NGVD (or other FIRM datum -see Section B, Item 7).
(c). FIRM Zone A (without BFE). The floor used as the reference level from the selected diagram is ❑-I . LI feet above ❑ or
below ❑ (check one) the highest grade adjacent to the building.
I
(d). FIRM Zone AO. The floor used as the reference level from the selected diagram is I_❑ . ❑ feet above ❑ or below ❑ (check
one) the highest grade adjacent to the building. If no flood depth number is available, is the building's lowest floor (reference
level) elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown
3. Indicate the elevation datum system used in determining the above reference level elevations: U NGVD'29 ❑ Other (describe
under Comments on Page 2). (NOTE: If the elevation datum used in measuring the elevations is different than that used on
the 'FIRM (see Section B, Item 77, then convert the elevations to the datum system used on the FIRM and show the conversion
equation under Comments on Page 2.)
4. Elevaation reference mark used appears on FIRM: ❑ Yes © No (See Instructions on Page 4)
5. The reference level elevation is based on: ❑X actual construction ❑ construction drawings
(NOTE: Use of construction drawings is only valid if the building does not yet have the reference level floor in place, in which
case this certificate will only be valid for the building during the course of construction. A post -construction Elevation Certificate
will be required once construction is complete.)
6. The elevation of the lowest grade immediately adjacent to the building is: LJ feet NGVD (or other FIRM datum -see
Section B, Item 7).
SECTION D COMMUNITY INFORMATION
1. It the community official responsible for verifying building elevations specifies that the reference level indicated in Section C, Item 1
is not the "lowest floor" as defined in the community's floodplain management ordinance, the elevation of the building's "lowest
floor" as defined by the ordinance is: I_I I I I J feet NGVD (or other FIRM datum -see Section B, Item 7).
2. Date of the start of construction or substantial improvement
FEMA Fonn 81-31, MAY 93 REPLACES ALL PREVIOUS EDITIONS SEE REVERSE SIDE FOR CONTINUATION
SECTION E CERTIFICATION
This certification is to be signed by a land surveyor, engineer, or architect who is authorized by state or local law to certify elevation
information when the elevation information for Zones Al—A30, AE, AH, A (with BFE),V1—V30,VE, and V (with BFE) is required.
Community officials who are authorized by local law or ordinance to provide floodplain management information, lmay also sign the
certification. In the case of Zones AO and A (without a FEMA or community issued BFE), a building official, a property owner, or an
owner's representative may also sign the certification.
Reference level diagrams 6, 7 and 8 - Distinguishing Features —If the certifier is unable to certify to breakaway/non-breakaway wall, I
enclosure size, location of servicing equipment, area use, wall openings, or unfinished area Feature(s), then list,Ithe Feature(s) not
included in the certification under Comments below. The diagram number, Section C, Item 1, must still be entered.
1 certify that the information in Sections B and C on this certificate represents my best efforts to interpret the data available.
I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 11001.
CERTIFIER'S NAME LICENSE NUMBER (or Affix Sea])
George M. A lor, Jr. 4015
TITLE COMPANY NAME
RegistAred Land Surveyor AYLOR, INC.
ADDRE S CITY STATE ZIP
4933 VE. Pine Knoll Way Stuart Florida 34997
DATE
Copies should be made of this Certificate for:1) community official, 2) Insurance agent/company, and13) building owner.
COMMENTS: I
I
I
- I
ROOD
ELEVAMON
ON
SLAB
A v
ZONES ZONES
LEVEL I GPADE
WITH
BASEMENT
A
ON PILES,
PIERS, OR COLUMNS
A v
The diagrams above illustrate the points at which the elevations should be measured in A Zones and V Zones.
Elevations for all A Zones should be measured at the top of the reference level floor.
Elevations for all V Zones should be measured at the bottom of the lowest horizontal structural member.
Page 2 I ;
ST. LUCIE COUNTY
3 DEPARTMENT OF COMMUNITY DEVELOPMENT
3300 VIRGINIA AMME, ROOM 301
FORT PIERCE, FL 36903-5653
607-467-1553
FILLED LANDS AFFIDAVIT
I, the undersigned, am the owner of the following described property, Tax '� NSo a,So I —
.S N1 E
to W.
i ' Pax ID/Iagal ducdptloNaddrou)
'br which I have applied to St. Lucie County for a Final Development Permit. In accepting
this Final Development Permit, BP Number . I acknowledge that
as owner of the above described property, and in accordance with Section 7.04.01(D),
St. Lucie County Land Development Code, I shall be responsible for assuring adequate
drainage so that the immediate community WILL NOT be, adversely affected. I further
acknowledge that in granting this permit for the development of this property, St. Lucie
County is neither obliged nor liable to provide for, or maintain in any form, adequate
drainage off 1my property which will not adversely affect the immediate community.
Properly Owner Properly %%J� Dele
(�nQ (signowro) T'9L
STATE OF FLORID& COUNTY OF l -WJ �-
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS D DAY OF 18�
WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED AS IDENTIFICATION.
SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY (304
NOTARY PUBLIC TITLE COMMISSION NUMBER
SLCCDV FORM NO.: 011-M
,
ST. LUCIE COUNTY
J DEPARTMENT OF COMMUNITY DEVELOPMENT
• 2300 VIRGINIA AVENUE, ROOM 2011
FT. PIERCE, FL 34982-5652
407-462-1553
DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE
This Certification lis to be completed by the project design architect or engineer. This Certification must be submitted with all
applications for bulding permit invohring the construction of new residence (single or multi -family), residential addition, any accessory
Structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided
that no structural 'walls, columns or other similar component is being effected) and certain other minor building permits. For further
assistance, please contact the Building Inspection Office at 462-1553 or 462-2172.
.
PROJECT NAME[
/Z6S/DEN CE
+� ;.<:: OFFJC,�
USB ONI:1(�! �•:< .
STREET ADDRESS
U 6 ' Ir
PR NUMBER
E'T GBS .SL A? fJ
PERMIT NUMBER
5r. �vcr� el)C>ti Ft- ,
OCCP. TYPE
CST. TYPE
,
CERTIFICATION STATEMENT:
CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS
HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OFTHE BUILDING CODES
CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL
ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND
FORCES SPECIFIED BY CURRENT CODE PROVISIONS.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (please check Or CD=Iete the appmriate tax)
1. BUILDING CODE EDITION USED rrEARI [ If SRrll ARM 7aa ..�.,�., ,....�.......
2
BUILDING DESIGN IS (CFEq( ONE) ENCLOSED t/ PARTIALLY ENCLOSED
OPEN BUILDING
3.
BUILDING HEIGHT:- 4 0 FT 4. WIND SPEED USED IN BUILDING DESIGN: 1/0 MPH
6.
WIND D(POSURE CLASSIFICATION (REFER TD 870SLIRE TABLES IN BUILDING CODE IDBMRED IN LINE 61): bvA 5—mL
6.
'
AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE
I
ZS - PSF
7.
PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE_��
i
PSF
a.
IMPORTANCERISE FACTOR (oBrAIN MW BULDING CDoEy.
i
9.
LOADS: FLOOR PSF ROOFIDEAD: / S PSF
ROOFIUVE: PSF
10.
WERE SH6AR'WALLS CONSIDERED FOR STRUCTURE (CrrECKONE) YES ✓ NO
explanation)
1f NO, why? (attach
11.
IS A CONTINUOUS LOAD PATH PROVIDED (ctEcK otE) YES ✓ NO
explanation)
If NO, why? (attach
ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK DIE) YES NO
If NO, why? (attach
_
N�
1�.
MINIMUM SOIL",BEARING PRESSURE: 29*0) PSF
AS WITNESSED i
CERTIFICATION IS I NAME: AIA'LX
MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION
UE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND
CERTIFICATION NO:
DESIGN FIRM: I DATE:
0/6.35
SHEET 1 OF *1
NOTE:PRO 8 D MINIMU4 FINISHED
FLOOR EV. TO BE 8.00' N.G.V.D.
i
FND. NAIL
INSEAWALL
ME
LOT 8
SECTION 2
EXISTING
RESIDENCE
0.5' OVER
LOT 10 SECTION 2
NETTLES ISLAND PROJECT
PLAT BOOK 16 , PAGES 1, IA-lJ
SAINT LUCIE COUNTY, FLORIDA
INDIAN RIVER
FND. NAIL
IN SEAWAL'
34.64'(P&M) 5.20
LOT 9
SECTION 2
VACANT
1.0' PROPOSED 8' X
PARKING AREA
FND. #5 = FND. #5
RFRAR 34.64'(P&M) REBAR ,
N 70" 30' 00" E
asphalt pavement
X5.66'. x5.59'
22' PRIVATE R/W-OPEN
COMMON USE
34 64'(P&M) `
24.8'
Ly1T ®10
ECTION 2
/PROPOSED
RESIDENCE
3
K5.56'
ELEV.-5.59' N.G.V.D.
PROPOSED 8' X 18'
-PARKING AREA
#5
69.28'(P&M
FND. NAIL
IN SEAWALL
L5.29'
LOT 11
SECTION 2
RESIDENCE
0.5' OVERHANG
FND.
REBAR
SETBACKS, LOCATIONS & CITY SEWER & WATER AVAILA.BILITIES TO BE VERIFIED BY CONTRACTOR
XPLOT PLAN & TOPO SURVEY � BOUNDARY SURVEY ❑ - FORM BOARD SURVEY ❑ - AS -BUILT SURVEY 0 - ELEV. ARE ASSUMED X ELEV. ARE N.G.V.D., 1979 DATA
LEGEND: D = DEED C = CALCULATED X - EXISTING GRADE PRO. -PRORATION DISTANCE M = MEASURED DISTANCE P = PLAT DISTANCE
P.C.P. = PERMANENT CONTROL POINT P.R.M. = PERMANENT REFERENCE MONUMENT ELEV. = ELEVATIONS R(R = RAILROAD CONC. = CONCRETE
MON. = MONUMENT C/L = CENTERUNE FND. - FOUND BLVD. = BOULEVARD ST. = STREET AVE. = AVENUE DR. = DRNE RD. = ROAD
LA. = LANE CIR. = CIRCLE N.G.V.D. —NATIONAL GEODERC VERTICAL DATUM SQ. = SQUARE FT. = FEET F.F. = FINISHED FLOOR # = NUMBER
N = NORTH S = SOUTH E = EAST W = WEST ° = DEGREES ' = MINUTES OR REEF " = SECONDS OR INCHES R&% = F1IGHTOF WAY s
RAD. = RADIAL ASP. - ASPHALT P.C. = POINTOFCURVE P.R.C. = POINT OF REVERSE CURVE P.T. = POINT OFTANGENT P.P. — POWERPOLE
N&D = NAIL & DISK C.M.P = CORRUGATED METAL PIPE PG = PAGE DB = DEED BOOK PB = PLAT BOOK BLK = BLOCK CH = CHORD
CB = CHORD BEARING
BEARINGS HEREON ARE REFERRED TO AN ASSUMED VALUE OF N 700 30' 00" E FOR THE SOUTH PROPERTY
)(LINE OF LOT 10, SECTION 2 , SAID BEARING IS IDENTICAL WITH THE PLAT OF RECORD.
THE SURVEY OF THE PROPERTY SHOWN HEREON IS IN
ACCORDANCE WITH THE DESCRIPTION FURNISHED BY
NOTES: LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR
EASEMENTS AND/OR RIGHTS -OF -WAY OF RECORD.
I HEREBY CERTIFY THATTHIS SURVEY MEETS MINIMUM TECHNICAL
I. .LAPI STANDARDS AS SET FORTH BY THE FLORIDA BOARD OF
PROFESSIONAL LAND SURVEYORS IN CHAPTER 21HH-6 FLORIDA
ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027,
$ CH OF THE PUBLIC RECORDS HAS BEEN MADE BY THIS FLORIDA STATUTES. REPRODUCTION IN ANY FORM IS PROHIBITED.
/-E FOR ACCURACY OR OMISSIONS. REBARS & CAPS ON ALL CORNERS UNLESS OTHERWISE NOTED.
LB4602 #5 REBARS.
THIS SURVEY SUBJECT TO EASEMENTS & ALL OTHER MATTERS OF RECORD AS RECORDED, WHETHER SHOWN ON SURVEY OR NOT.
I HEREBY CERTIFY THAT THE SURVEY SHOWN HEREON IS A TRUE AND CORRECT SURVEY MADE UNDER MY SUPERVISION AND DIRECTION,
AN, THAT SAID SURVEY IS ACCURATE TO THE BEST OF MY KNOWLEDGE AND BELIEF, AND TH THERE ARE NO APPARENT ABOVE GROUND
ENbROACHMENTS UNLESS SHOWN OR NOTED. THIS SURVEY NOT TO BE USED FOR FENC I RELATION, SPRINKLER SYSTEMS, SHRUBS
OR ANY OTHER UTILITIES Wr HOUT REVERIFICATION OF PROPERTY CORNEAS.
THIS SURVEY NOT VALID UNLESS SEALED GEORGE M. AYLOR, JR.
WITH AN EMBOSSED SURVEYOR'S SEAL REGISTERED LAND SURVEYOR, FLORIDA CERTIFICATE #4015
, _,
SCALE 1" 20'
CHECKED BY
/� INC.JOBNO.
AYLOR, N
7574-94
DRAWN BY GMA
LAND SURVEYING
FIELD BK. NO.
4933 S.E. PINE KNOLL WAY, STUART, FLORIDA 34997 — MAILING ADDRESS
REFERENCES
FIELD WORK DATE 9-30-94
2201 S.E. INDIAN STREET, UNIT H-19, STUART, FLORIDA 34997— (OFFICE)
FLOOD ZONE „ AE „
TELEPHONE (407) 287-06U
DATE 10-3-94
REVISED-9-13-95-ADD PROPPSED
RESIDENCE
.. I