Loading...
HomeMy WebLinkAboutPRODUCT INFORMATIONJob: Short Form Date: Apr 01, 2007 Entire House By: kmm Accurate Drafting and Design, Inc. 4810 Biscayne Ddve, Naples, FL 34112 Phone: 239-774-1872 Fax: 239-417-2951 EM • • • For: Roy Sowders 5700 Oleander Avenue, Fort Pierce, FL 34982 Htg Clg Outside db (°F) 42 90 Method Inside db (°F) 70 78 Construction quality Design TD (°F) 28 1 L Fireplaces Daily range Inside humidity (%) 50 Moisture difference (gr/lb) 55 HEATING EQUIPMENT Make Trade Model Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 Btuh 0 Btuh 0 OF 1534 cfm 0.041 cfm/Btuh 0.50 in H2O Infiltration SCANNED BY Simplified Average 0 COOLING EQUIPMENT Make Goodman Mfg. Trade Existing Cond CLJ42-1C Coil ARUF049-OOA-IA Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 12 SEER 30375 Btuh 10125 Btuh 40500 Btuh 1534 cfm 0.048 cfm/Btuh 0.50 in H2O 0.86 ROOM NAME Area Htg Cig l; d Htg AVF (ftAddition load (CCngAVF 388 6206 5449 257 263 Existing House 1563 30877 26391 1277 1271 Entire House 1951 37082 31840 1534 1534 Other equip loads 1201 515 30737 Equip. @ 0.95 RSM Latent cooling 5326 38283 36063 1534 1534 TOTALS 1951 BoldWalic values have been manually ovenitltlen Printout certified by ACCA to meet all requirements of Manual J 8th Ed. „ wrightsoft Right -Suite Residemial6.0.53 RSR23386 2007-Apr-1318:26:26 C.Towments and SettingsWdministratoMesldop%Wdghtso8 on serverladomTavldmoms.iry Calc=MJ Pagel FORM 60OA-2004R EnergyGauge® 4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Sowders Addition Builder: Address: 5700 Oleander Avenue Permitting Office: City, State: Fort Pierce, FL 34982- Permit Number: Owner: Roy Sowders Jurisdiction Number: Climate Zone: Central 1. New construction or existing Addition _ 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 0 5. Is this a worst case? No 6. Conditioned floor area (ft') 388 ft' 7. Glass typel and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a.(Sngle, U=1.1) 32.0 ft' _ b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 32.0 ft' 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 51.0(p) ft _ b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior R=11.0, 410.0 ft' _ b. N/A — c. N/A — d. N/A — e. N/A — 10. Ceiling types a. Under Attic R=19.0, 388.0 ft' b. N/A — c. N/A — 11. Ducts — a. N/A b. N/A — 12. Cooling systems a. N/A = b. N/A — c. N/A 13. Heating systems FILE COPPY 14. Hot water systems a. N/A — b. N/A — c. Conservation credits _ (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.08 Total as -built points: 2901 PASS Total base points: 3182 I hereby certify that the plans and specifications covered by this calculation are in compliance with orida Energy Code. PREPARED BY: 4CAT!-91►) AA^I2�V DATE: 4i131a 9 1 hereby certify that this building, as designed, is in compliance with the Florida Energy Code OWNER/AGENT: DATE: 61 AV <3 1 Predominant class type. For actual glass type and areas, see Summer Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCSB v4.5.2) FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: 5700 Oleander Avenue, Fort Pierce, FL, 34982- PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Floor Area Type/SC Overhang Ornt Len Hgt Area X SPM X SOF = Points .18 388.0 24.35 1701.0 1.Single,U=1.10,Clear N 2.0 7.0 32.0 30.32 0.92 896.0 As -Built Total: 32.0 896.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 1. Frame, Wood, Exterior 11.0 410.0 1.90 779.0 Exterior 410.0 1.90 779.0 Base Total: 410.0 779.0 As -Built Total: 410.0 779.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 388.0 2.13 826.4 1. Under Attic 19.0 388.0 2.82 X 1.00 1094.2 Base Total: 388.0 826.4 As -Built Total: 388.0 1094.2 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 51.0(p) -31.8 -1621.8 1. Slab -On -Grade Edge Insulation 0.0 51.0(p) -31.90 -1626.9 Raised 0.0 0.00 0.0 Base Total: .1621.8 As -Built Total: 61.0 -1626.9 INFILTRATION , Area X BSPM = Points Area X SPM = Points 388.0 14.31 5552.3 388.0 14.31 5552.3 Summer Base Points: 7236.9 Summer As -Built Points: 6694.5 Total Summer X System = Cooling Points Multiplier Points Total X Cap Component Ratio X Duct X System X Multiplier Multiplier Credit = Multiplier Cooling Points (System - Points) (DM x DSM x AHU) 7236.9 0.3250 2352.0 1 6694.6 1.00 1.000 0.310 1.000 2076.1 EnergyGaugeTM DCA Form 60OA-2004R FORM 60OA-2004R EnergyGauge® 4.5.2 J WINTER CALCULATIONS Residential Whole Building Performance Method A -Details ADDRESS: 5700 Oleander Avenue, Fort Pierce, FL, 34982- PERMIT #: BASE AS -BUILT GLASS TYPES X Conditioned X BWPM = Points Overhang .18 Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 388.0 9.11 636.0 1.Single,U=1.10,Clear N 2.0 7.0 32.0 13.21 1.00 421.0 As -Built Total: 32.0 421.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 1. Frame, Wood, Exterior 11.0 410.0 2.00 820.0 Exterior 410.0 2.00 820.0 Base Total: 410.0 820.0 As -Built Total: 410.0 820.0 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior 0.0 0.00 0.0 Base Total: 0.0 0.0 1 As -Built Total: 0.0 0.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 388.0 0.64 248.3 1. Under Attic 19.0 388.0 0.87 X 1.00 337.6 - Base Total: 388.0 248.3 As -Built Total: 388.0 337.6 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 51.0(p) -1.9 -96.9 1. Slab -On -Grade Edge Insulation 0.0 51.0(p) 2.50 127.5 Raised 0.0 0.00 0.0 Base Total: -96.9 As -Built Total: 51.0 127.5 INFILTRATION Area X BWPM = Points Area X WPM = Points 388.0 .0.28 -108.6 388.0 -0.28 -108.6 Winter Base Points: 1498.8 Winter As -Built Points: 1597.4 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) 14P8.8 0.5540 830.3 1 1597.4 1.00 1.000 0.516 1.000 8278 EnergyGaugeTM DCA Form 60OA-2004R FORM 60OA-2004R EnergyGaugeO4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 5700 Oleander Avenue, Fort Pierce, FL, 34982- PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 0 2460.00 0.0 0 1.00 2460.00 1.00 7380.0 As -Built Total: 0.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 2352 830 0 3182 2076 825 0 2901 PASS EnergyGaugeTM DCA Form 60OA-2004R FORM 60OA-2004R EnergyGauge® 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 5700 Oleander Avenue, Fort Pierce, FL, 34982- PERMIT #: QA ea uror Tonrrnur oFnnC7InN CnMPI IANCF CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfrn/s .ft. window area:.5 cfrn/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perlimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavil between floors. Additional Infiltration regts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each s stem. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTM DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 87.3 The higher the score, the more efficient the home. Roy Sowders, 5700 Oleander Avenue, Fort Pierce, FL, 34982- 11. New construction or existing Addition _ 2. Single family or multi -family Single family _ 3. Number of units, if multi -family I _ 4. Number of Bedrooms 0 _ 5. Is this a worst case? No _ 6. Conditioned floor area (112) 388 ft' _ 7. Glass type and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a.(Sngle, U=1.1) 32.0 112 — b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 32.0 112 — 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 51.0(p) It b. N/A — c. N/A — 9. Wall types a. Frame, Wood, Exterior R=11.0, 410.0 ft' _ b. N/A — c. N/A — d. N/A — e. N/A — 10. Ceiling types a. Under Attic R=19.0, 388.0 ft2 _ • b. N/A — c. N/A — 11. Ducts a. N/A — b. N/A — 12. Cooling systems a. N/A b. N/A c. N/A 13. Heating systems a. N/A b. N/A c. N/A 14. Hot water systems a. N/A b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code: mpliant features. Builder Signature: �rfr�95Log� Date: G/ Z 0 y Address of New Home: ✓ 2,- f/� l° fnn�� Q% / L Zip: *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86for a US EPA/DOE EnergyStarr'designation), your home may qual fy for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areEnergyGaugE® (Version: FL,RCSI3av4.5 2) BUILDING INPUT SUMMARY REPORT Title: Sowders Addition Family Type: Single Address Type: Street Address F- Owner: Roy Sowders New/Existing: Addition Lot#: WA V #of Units: 1 Bedrooms: 0 Subdivision: NIA OBuilder Name: (blank) Conditioned Area: 388 Platbook: N/A Climate: Central Total Stories: 1 Street: 5700 Oleander Avenue 0 n. Permit Office: (blank) Worst Case: No County: Saint Lucie Jurisdiction #: (blank) Rotate Angle: 0 City, St, Zip: Fort Pierce, FL, 34982- N # Floor Type R-Val ArealPerimeter Units to # Door Type Orientation Area Units Slab -On -Grade Edge Insulation 0.0 51.0(p) ft 1 O O1 •O 0 LL # Celling Type R-Val Area Base Area Units :7 # System Type Efficiency Capacity 1 Under Attic 19.0 388.0ft' 388.0ft' 1 N 0 Z Z J J OO W Credit Multipllers: None Credit Multipllers: CrossVent, PT V L) # Wall Type Location R-Val Area Units # System Type Efficiency Capacity 1 Frame - Wood Exterior 11.0 41O.OfL2 1 N Z . J F J W = Credit MUllvtipllers: MZ-H, PT # SupReturnply VVSS�I Location LocaUonler SRupply Length # Panes Tint Omt Area OH Length OH Hght Uni 1 S, U=1.1 Clear N 18.011- 2.0 It 7.0 ft 2 F 0 0 Credit Multipllers: None # System Type EF Cap. Conservation Type Con. EF W H i N # Use Default? Annual Operating Cost Electric Rate 7 1 Yes N/A WA Q LL Z_ EnergyGaugeO (Version: FLRCSB v4.5.2) c Ca's'l `7 PRODUCT SPECIFICATIONS Performance Ratings (cont.) fro dense �zs Evapoor ModelToWt BT(1 Se ` le BT H 24,900 E.,n...4� 9.80 11.00 503480 . Decibel 77 AC36-XX 33,600 ACHP3632-1 33,000 24,500 9.80 11.60 503481 77 AEPT036.00'-1' 36,000 26,300 11.50 13.00 517571 77 AH36 35,400 26,200 10.50 12.00 503483 77 ARPF048.00B-1' 36,000 26,300 10.50 12.00 517580 77 ARPT036-00'-I. 34,000 24,500 10.00 11.20 517592 77 ARPT042-00'-1' 36,000 26,300 10.50 12.00 517611 77 ARUF036.00*-1' 34,000 24,500 10.00 11.20 517584 77 ARUF042-00'-1' 36,000 26,300 10.50 12.00 517553 77 CU36-1' AWB36-XX 36,000 26,300 10.50 12.00 503489 77 CA'F036'2'+EEP 34,000 24,500 10.00 11.20 503490 77 CA'F042.2'+EEP 36,000 26,300 10.50 12.00 77 CA'F048'2'+EEP 36,000 26,300 10.50 12.00 77 CHPF030A2*+EEP 34,000 24,500 10.00 11.20 F5035O6 77 CHPF042B2A+EEP 36,000 26,300 10.50 12.00 77 CHPF048C2'+EEP 36,000 26,300 10.50 12.00 77 H36F+EEP 34,000 24,500 10.00 11.20 77 H49F+EEP 36,000 26,300 1 10.50 1 12.00 1 503516 77 Mon en a 0 Eva ot�tor ldodel ritat T FI �sY lbIBT� EER CU4 -1' versa ++� AEPT060-00'-1' ARPF048-00B-1' ARPT042-00'-1' ARPT049.00'-1' 41,000 40,500 39,500 40,500 30,700 30,200 29,500 30,200 11.50 10.50 10.00 10.50 13.00 12.00 11.30 12.00 517550 517606 517556 517608 77 77 77 77 ARUF042-00'-1' 39,500A30,20U 10.00 11.30 517570 77 ARUF048-00'-1' ARUF049.00'-1' CA'F042'2'+EEP CA*F060*2*+EEP CHPF048D2'+EEP H49F+EEP H60F+EEP 40,00010.10 40,50010.50 39,00010.00 40,50010.50 40,00010.50 39,00010.00 40,50010.50 11.50 12.00 11.30 12.00 12.00 11.30 12.00 517' 517559 503530 503531 503540 468541 468553 77 77 77 77 77 77 77 NOTES: 1) Seasonal Energy EfficiencyRatio 2) Energy Efficiency Ratio @ 80 °F/67 OF Inside - 95'F 3) When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. 4) Note: XX of A Model Designate Electric Heat Quantity. 5) EEP - Order from Service Dept Part No. 1313707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Amana Gas Furnace contains the EEP cooling time delay. 6 Ln H a W U O U. cz W a o. LLI m a O O O O O .mo M O N^ O m m O O O Ill m O to O to P In O M N P m 0 0 m 1� •O M Vl Q C P� ul m OPD f� 7 OPO I� Q P Q O p M n? N a `'- m O O O O O O O O M O N •D P P S 'P m N m M .0 P 1� •- m •D M N P_ 1� I(t N T •D M N m C N P n I[t R a � � � O O {O O II'I � O In Vl N O O O O O t� `o tt Q 1� M •O 1� N •n � u+ N o ��.'u� � X N O O N O O N O u� M M O m p V 1� N N P O I(l V' M m P 1� m �n .O O m O m N O P 1� m N O N I� •� Y N O m Ill NCB P n O P I� O m V M N •p N P� a� '"' m o_ 0 0 o m m o vl o 0 o M 1� •o .o m y .o {� o o ul .o..o 1Zi P •O N 1� M N O •O '? M O •O QN O P •D O P O�� M N O •O Y ("^ a 9 ' CLLJ In Itl I(l O O vl In vl O vl I(f ul •O O f� N .o P •O N ? N O n—- _ 7 M O— 7 M P— W V O^ P— p a^D J^ OnD N— '- N ,- — N mj�m m a m a 0 m a 0 m a 0 p p Q � � � •o •p ,p ,o � m m m m • P O N � m m Y N N M N `Q' rn O •� ONO M �n�M n LL � � OIL � LL tpi Ct " IL 4. LL la_ LL Ipi _ _ a a a a d a a a a a a r I� 13.600.2.A.3 Additions. 13-600.2.A.3.1 Additions Complying Alone. Additions to existing buildings shall follow the same Method A calculation procedure as new construction with the following q onents of the addition itself, 1. Calculations shall be conducted using o Iwhich separate the addition from unconditioned Including those pre-existing comp spaces. g stem Multipliers shall be equal to the Baseline System Multiplier 2. Heating and Cooling Yequipment or to service the ui inert may qualify for multizone credit (see unless new equipment is installed to replace existing addition specifically. Addition of new eq P section 607.2.A.3.2) if all other criteria are met. The multiplier for the new ductwork to supply the addition shall be used in the calculation. supplemental water heater is is not included in the calculation f an alternative water heater (gas, solar, 3, Water heating' water heater is replaced, Installed an existing is installed to gain credit. HRU, dedicated heat pump) 13-600.2.A.3.2 Additions Unable To Comply Alone. Section 1)1.2.2 allows additions to either comply with the Code requirements for the addition alone or by demonstrating that the entire building including the addition complies with the Code requirements for news ued tbuildings. Sectionate.4.2.1 compliance. contains restrictions which shall apply if the entire building 13.600.2.A.4 Multifamily occupancies. 13.600.2.AA.1 Common Conditioned Spaces. Common conditioned spaces occurring in multifamily buildings that are not part of specific tenancy units, such as corridors, lobbies, recreation rooms, offices, etc., shall be calculated using one of the following procedures. percent (5%) of 1. No energy use calculation is required for common areas if less than five the building area is used for such common areas. 2. Corridors, lobbies and similar areas shall be calcstructure such ulated using Chapter 4. t 3. Non -reins shall be calculated nt accordance wimultifamith Sub chapter 4. as cafeterias, offices, and gyms 13.600.2.A.5 Worst Case Calculations. ich are identical in configuration, square footage, and building Residential occupancies wh comply with the Code by performing a a worst case calculation. When materials may P Y copies peof rform Form 6o0A shall besubmitted referenced submitting worst case calculations, cop with each set of plans, dependent on the requirements of the buildingdepartment. 13.600.2.B Performance Calculation Procedures for Method B. No performance requirements exist for Method B. 13-600.2.0 Performance Calculation Procedures for Method C. No performance requirements exist for Method C. 13.600.3 Certification of Compliance. 13,.600.3.ABC.1 Code Compliance Preparation.