HomeMy WebLinkAboutPRODUCT INFORMATIONJob:
Short Form Date: Apr 01, 2007
Entire House By: kmm
Accurate Drafting and Design, Inc.
4810 Biscayne Ddve, Naples, FL 34112 Phone: 239-774-1872 Fax: 239-417-2951
EM • • •
For: Roy Sowders
5700 Oleander Avenue, Fort Pierce, FL 34982
Htg Clg
Outside db (°F) 42 90 Method
Inside db (°F) 70 78 Construction quality
Design TD (°F) 28 1 L Fireplaces
Daily range
Inside humidity (%) 50
Moisture difference (gr/lb) 55
HEATING EQUIPMENT
Make
Trade
Model
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
80 AFUE
0
Btuh
0
Btuh
0
OF
1534
cfm
0.041
cfm/Btuh
0.50
in H2O
Infiltration
SCANNED
BY
Simplified
Average
0
COOLING EQUIPMENT
Make Goodman Mfg.
Trade Existing
Cond CLJ42-1C
Coil ARUF049-OOA-IA
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
12 SEER
30375
Btuh
10125
Btuh
40500
Btuh
1534
cfm
0.048
cfm/Btuh
0.50
in H2O
0.86
ROOM NAME
Area
Htg
Cig l; d
Htg AVF
(ftAddition
load
(CCngAVF
388
6206
5449
257
263
Existing House
1563
30877
26391
1277
1271
Entire House
1951
37082
31840
1534
1534
Other equip loads
1201
515
30737
Equip. @ 0.95 RSM
Latent cooling
5326
38283
36063
1534
1534
TOTALS 1951
BoldWalic values have been manually ovenitltlen
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
„ wrightsoft Right -Suite Residemial6.0.53 RSR23386 2007-Apr-1318:26:26
C.Towments and SettingsWdministratoMesldop%Wdghtso8 on serverladomTavldmoms.iry Calc=MJ Pagel
FORM 60OA-2004R EnergyGauge® 4.5.2
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name:
Sowders Addition
Builder:
Address:
5700 Oleander Avenue
Permitting Office:
City, State:
Fort Pierce, FL 34982-
Permit Number:
Owner:
Roy Sowders
Jurisdiction Number:
Climate Zone:
Central
1. New construction or existing
Addition _
2. Single family or multi -family
Single family _
3. Number of units, if multi -family
1 _
4. Number of Bedrooms
0
5. Is this a worst case?
No
6. Conditioned floor area (ft')
388 ft'
7. Glass typel and area: (Label reqd.
by 13-104.4.5 if not default)
a. U-factor:
Description Area
(or Single or Double DEFAULT) 7a.(Sngle, U=1.1) 32.0 ft' _
b. SHGC:
(or Clear or Tint DEFAULT)
7b. (Clear) 32.0 ft'
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 51.0(p) ft _
b. N/A
c. N/A
9. Wall types
a. Frame, Wood, Exterior
R=11.0, 410.0 ft' _
b. N/A
—
c. N/A
—
d. N/A
—
e. N/A
—
10. Ceiling types
a. Under Attic
R=19.0, 388.0 ft'
b. N/A
—
c. N/A
—
11. Ducts
—
a. N/A
b. N/A
—
12. Cooling systems
a. N/A =
b. N/A —
c. N/A
13. Heating systems
FILE
COPPY
14. Hot water systems
a. N/A —
b. N/A —
c. Conservation credits _
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits _
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.08 Total as -built points: 2901 PASS
Total base points: 3182
I hereby certify that the plans and specifications covered by
this calculation are in compliance with orida Energy
Code.
PREPARED BY: 4CAT!-91►) AA^I2�V
DATE: 4i131a 9
1 hereby certify that this building, as designed, is in compliance
with the Florida Energy Code
OWNER/AGENT:
DATE: 61 AV <3
1 Predominant class type. For actual glass type and areas, see Summer
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
& Winter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCSB v4.5.2)
FORM 60OA-2004R
EnergyGauge® 4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: 5700 Oleander Avenue, Fort Pierce, FL, 34982- PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM = Points
Floor Area
Type/SC
Overhang
Ornt Len Hgt Area X SPM X SOF = Points
.18 388.0
24.35
1701.0
1.Single,U=1.10,Clear
N 2.0 7.0 32.0
30.32 0.92
896.0
As -Built Total:
32.0
896.0
WALL TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM =
Points
Adjacent
0.0 0.00
0.0
1. Frame, Wood, Exterior
11.0 410.0
1.90
779.0
Exterior
410.0 1.90
779.0
Base Total:
410.0
779.0
As -Built Total:
410.0
779.0
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM =
Points
Adjacent
0.0 0.00
0.0
Exterior
0.0 0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
CEILING TYPES Area X BSPM
= Points
Type
R-Value Area X SPM X SCM =
Points
Under Attic
388.0 2.13
826.4
1. Under Attic
19.0 388.0 2.82
X 1.00
1094.2
Base Total:
388.0
826.4
As -Built Total:
388.0
1094.2
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM =
Points
Slab
51.0(p) -31.8
-1621.8
1. Slab -On -Grade Edge Insulation 0.0 51.0(p)
-31.90
-1626.9
Raised
0.0 0.00
0.0
Base Total:
.1621.8
As -Built Total:
61.0
-1626.9
INFILTRATION
, Area X BSPM
= Points
Area X SPM =
Points
388.0 14.31
5552.3
388.0
14.31
5552.3
Summer Base Points: 7236.9
Summer As -Built Points:
6694.5
Total Summer X System = Cooling
Points Multiplier Points
Total X Cap
Component Ratio
X Duct X System X
Multiplier Multiplier
Credit =
Multiplier
Cooling
Points
(System - Points)
(DM x DSM x AHU)
7236.9
0.3250
2352.0
1 6694.6 1.00
1.000 0.310
1.000
2076.1
EnergyGaugeTM DCA Form 60OA-2004R
FORM 60OA-2004R
EnergyGauge® 4.5.2
J WINTER CALCULATIONS
Residential Whole Building Performance Method A -Details
ADDRESS: 5700 Oleander Avenue, Fort Pierce, FL, 34982- PERMIT #:
BASE
AS -BUILT
GLASS TYPES
X Conditioned X BWPM =
Points
Overhang
.18
Floor Area
Type/SC
Ornt Len Hgt Area X WPM X WOF = Point
.18 388.0
9.11
636.0
1.Single,U=1.10,Clear
N 2.0 7.0 32.0 13.21 1.00
421.0
As -Built Total:
32.0
421.0
WALL TYPES
Area X
BWPM
= Points
Type
R-Value Area X WPM =
Points
Adjacent
0.0
0.00
0.0
1. Frame, Wood, Exterior
11.0 410.0 2.00
820.0
Exterior
410.0
2.00
820.0
Base Total:
410.0
820.0
As -Built Total:
410.0
820.0
DOOR TYPES
Area X
BWPM
= Points
Type
Area X WPM =
Points
Adjacent
0.0
0.00
0.0
Exterior
0.0
0.00
0.0
Base Total:
0.0
0.0 1
As -Built Total:
0.0
0.0
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X WPM X WCM =
Points
Under Attic
388.0
0.64
248.3
1. Under Attic
19.0 388.0 0.87 X 1.00
337.6
- Base Total:
388.0
248.3
As -Built Total:
388.0
337.6
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value Area X WPM =
Points
Slab
51.0(p)
-1.9
-96.9
1. Slab -On -Grade Edge Insulation 0.0 51.0(p) 2.50
127.5
Raised
0.0
0.00
0.0
Base Total:
-96.9
As -Built Total:
51.0
127.5
INFILTRATION
Area X
BWPM
= Points
Area X WPM =
Points
388.0
.0.28
-108.6
388.0 -0.28
-108.6
Winter Base Points:
1498.8
Winter As -Built Points:
1597.4
Total Winter X
System
= Heating
Total X Cap
X Duct X System X Credit =
Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
(System - Points)
(DM x DSM x AHU)
14P8.8
0.5540
830.3
1 1597.4 1.00
1.000 0.516 1.000
8278
EnergyGaugeTM DCA Form 60OA-2004R
FORM 60OA-2004R EnergyGaugeO4.5.2
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: 5700 Oleander Avenue, Fort Pierce, FL, 34982-
PERMIT #:
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
0 2460.00 0.0 0 1.00 2460.00 1.00 7380.0
As -Built Total: 0.0
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
2352 830
0
3182
2076
825 0 2901
PASS
EnergyGaugeTM DCA Form 60OA-2004R
FORM 60OA-2004R EnergyGauge® 4.5.2
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: 5700 Oleander Avenue, Fort Pierce, FL, 34982- PERMIT #:
QA ea uror Tonrrnur oFnnC7InN CnMPI IANCF CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfrn/s .ft. window area:.5 cfrn/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perlimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavil between floors.
Additional Infiltration regts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each s stem.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTM DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 87.3
The higher the score, the more efficient the home.
Roy Sowders, 5700 Oleander Avenue, Fort Pierce, FL, 34982-
11. New construction or existing
Addition _
2. Single family or multi -family
Single family _
3. Number of units, if multi -family
I _
4. Number of Bedrooms
0 _
5. Is this a worst case?
No _
6. Conditioned floor area (112)
388 ft' _
7. Glass type and area: (Label reqd.
by 13-104.4.5 if not default)
a. U-factor:
Description Area
(or Single or Double DEFAULT)
7a.(Sngle, U=1.1) 32.0 112 —
b. SHGC:
(or Clear or Tint DEFAULT)
7b. (Clear) 32.0 112 —
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 51.0(p) It
b. N/A
—
c. N/A
—
9. Wall types
a. Frame, Wood, Exterior
R=11.0, 410.0 ft' _
b. N/A
—
c. N/A
—
d. N/A
—
e. N/A
—
10. Ceiling types
a. Under Attic
R=19.0, 388.0 ft2 _
• b. N/A
—
c. N/A
—
11. Ducts
a. N/A
—
b. N/A
—
12. Cooling systems
a. N/A
b. N/A
c. N/A
13. Heating systems
a. N/A
b. N/A
c. N/A
14. Hot water systems
a. N/A
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code: mpliant features.
Builder Signature: �rfr�95Log� Date: G/ Z 0 y
Address of New Home: ✓ 2,- f/� l° fnn�� Q% / L Zip:
*NOTE. The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86for a US EPA/DOE EnergyStarr'designation),
your home may qual fy for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of Community Affairs at 8501487-1824.
1 Predominant glass type. For actual glass type and areEnergyGaugE® (Version: FL,RCSI3av4.5 2)
BUILDING INPUT SUMMARY REPORT
Title: Sowders Addition Family Type: Single Address Type: Street Address
F-
Owner: Roy Sowders New/Existing: Addition Lot#: WA
V
#of Units: 1 Bedrooms: 0 Subdivision: NIA
OBuilder
Name: (blank) Conditioned Area: 388 Platbook: N/A
Climate: Central Total Stories: 1 Street: 5700 Oleander Avenue
0
n.
Permit Office: (blank) Worst Case: No County: Saint Lucie
Jurisdiction #: (blank) Rotate Angle: 0 City, St, Zip: Fort Pierce, FL, 34982-
N
# Floor Type R-Val ArealPerimeter Units
to
# Door Type Orientation Area Units
Slab -On -Grade Edge Insulation 0.0 51.0(p) ft 1
O
O1
•O
0
LL
# Celling Type R-Val Area Base Area Units
:7
# System Type Efficiency Capacity
1 Under Attic 19.0 388.0ft' 388.0ft' 1
N
0
Z
Z
J
J
OO
W
Credit Multipllers: None
Credit Multipllers: CrossVent, PT
V
L)
# Wall Type Location R-Val Area Units
# System Type Efficiency Capacity
1 Frame - Wood Exterior 11.0 41O.OfL2 1
N
Z
.
J
F
J
W
=
Credit MUllvtipllers: MZ-H, PT
# SupReturnply
VVSS�I
Location LocaUonler SRupply Length
# Panes Tint Omt Area OH Length OH Hght Uni
1 S, U=1.1 Clear N 18.011- 2.0 It 7.0 ft 2
F
0
0
Credit Multipllers: None
# System Type EF Cap. Conservation Type Con. EF
W
H
i N # Use Default? Annual Operating Cost Electric Rate
7 1 Yes N/A WA
Q LL
Z_
EnergyGaugeO (Version: FLRCSB v4.5.2)
c
Ca's'l `7
PRODUCT SPECIFICATIONS
Performance Ratings (cont.)
fro dense
�zs
Evapoor ModelToWt
BT(1
Se ` le BT H
24,900
E.,n...4�
9.80
11.00
503480
. Decibel
77
AC36-XX
33,600
ACHP3632-1
33,000
24,500
9.80
11.60
503481
77
AEPT036.00'-1'
36,000
26,300
11.50
13.00
517571
77
AH36
35,400
26,200
10.50
12.00
503483
77
ARPF048.00B-1'
36,000
26,300
10.50
12.00
517580
77
ARPT036-00'-I.
34,000
24,500
10.00
11.20
517592
77
ARPT042-00'-1'
36,000
26,300
10.50
12.00
517611
77
ARUF036.00*-1'
34,000
24,500
10.00
11.20
517584
77
ARUF042-00'-1'
36,000
26,300
10.50
12.00
517553
77
CU36-1'
AWB36-XX
36,000
26,300
10.50
12.00
503489
77
CA'F036'2'+EEP
34,000
24,500
10.00
11.20
503490
77
CA'F042.2'+EEP
36,000
26,300
10.50
12.00
77
CA'F048'2'+EEP
36,000
26,300
10.50
12.00
77
CHPF030A2*+EEP
34,000
24,500
10.00
11.20
F5035O6
77
CHPF042B2A+EEP
36,000
26,300
10.50
12.00
77
CHPF048C2'+EEP
36,000
26,300
10.50
12.00
77
H36F+EEP
34,000
24,500
10.00
11.20
77
H49F+EEP
36,000
26,300
1 10.50
1 12.00
1 503516
77
Mon en a
0 Eva ot�tor ldodel
ritat T FI
�sY lbIBT�
EER
CU4 -1'
versa ++�
AEPT060-00'-1'
ARPF048-00B-1'
ARPT042-00'-1'
ARPT049.00'-1'
41,000
40,500
39,500
40,500
30,700
30,200
29,500
30,200
11.50
10.50
10.00
10.50
13.00
12.00
11.30
12.00
517550
517606
517556
517608
77
77
77
77
ARUF042-00'-1'
39,500A30,20U
10.00
11.30
517570
77
ARUF048-00'-1'
ARUF049.00'-1'
CA'F042'2'+EEP
CA*F060*2*+EEP
CHPF048D2'+EEP
H49F+EEP
H60F+EEP
40,00010.10
40,50010.50
39,00010.00
40,50010.50
40,00010.50
39,00010.00
40,50010.50
11.50
12.00
11.30
12.00
12.00
11.30
12.00
517'
517559
503530
503531
503540
468541
468553
77
77
77
77
77
77
77
NOTES:
1) Seasonal Energy EfficiencyRatio
2) Energy Efficiency Ratio @ 80 °F/67 OF Inside - 95'F
3) When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on
the piston kit chart supplied with the indoor unit.
4) Note: XX of A Model Designate Electric Heat Quantity.
5) EEP - Order from Service Dept Part No. 1313707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is
not interchangeable with B13707-35S.
The Amana Gas Furnace contains the EEP cooling time delay.
6
Ln
H
a
W
U
O
U.
cz
W
a
o.
LLI
m
a
O
O
O
O
O
.mo
M
O
N^
O
m
m
O
O
O
Ill
m
O
to
O
to
P
In
O
M
N
P
m
0
0
m
1�
•O
M
Vl
Q
C
P�
ul
m
OPD
f�
7
OPO
I�
Q
P
Q
O
p
M
n?
N
a
`'-
m
O
O
O
O
O
O
O
O
M
O
N
•D
P
P
S
'P
m
N
m
M
.0
P
1�
•-
m
•D
M
N
P_
1�
I(t
N
T
•D
M
N
m
C
N
P
n
I[t
R
a
�
�
�
O
O
{O
O
II'I
�
O
In
Vl
N
O
O
O
O
O
t�
`o
tt
Q
1�
M
•O
1�
N
•n
�
u+
N
o
��.'u� �
X N
O
O
N
O
O
N
O
u�
M
M
O
m
p
V
1�
N
N
P
O
I(l
V'
M
m
P
1�
m
�n
.O
O
m
O
m
N
O
P
1�
m
N
O
N
I�
•�
Y
N
O
m
Ill
NCB
P
n
O
P
I�
O
m
V
M
N
•p
N
P�
a�
'"'
m
o_
0
0
o
m
m
o
vl
o
0
o
M
1�
•o
.o
m
y
.o
{�
o
o
ul
.o..o
1Zi
P
•O
N
1�
M
N
O
•O
'?
M
O
•O
QN
O
P
•D
O
P
O��
M
N
O
•O
Y
("^
a
9 '
CLLJ
In
Itl
I(l
O
O
vl
In
vl
O
vl
I(f
ul
•O
O
f�
N
.o
P
•O
N
?
N
O
n—-
_
7
M
O—
7
M
P—
W
V
O^
P—
p
a^D
J^
OnD
N—
'-
N
,-
—
N
mj�m
m
a
m
a
0
m
a
0
m
a
0
p
p
Q
�
�
�
•o
•p
,p
,o
�
m
m
m
m
•
P
O
N
�
m
m
Y
N
N
M
N
`Q'
rn
O
•�
ONO
M
�n�M
n
LL
�
�
OIL
�
LL
tpi
Ct "
IL
4.
LL
la_
LL
Ipi
_
_
a
a
a
a
d
a
a
a
a
a
a
r
I�
13.600.2.A.3 Additions.
13-600.2.A.3.1 Additions Complying Alone.
Additions to existing buildings shall
follow the same Method A calculation procedure as new
construction with the following q onents of the addition itself,
1. Calculations shall be conducted using
o Iwhich separate the addition from unconditioned
Including those pre-existing comp
spaces. g stem Multipliers shall be equal to the Baseline System Multiplier
2. Heating and Cooling Yequipment or to service the
ui inert may qualify for multizone credit (see
unless new equipment is installed to replace existing
addition specifically. Addition of new eq P
section 607.2.A.3.2) if all other criteria are met. The multiplier for the new ductwork to
supply the addition shall be used in the calculation. supplemental water heater is
is not included in the calculation f an alternative water heater (gas, solar,
3, Water heating' water heater is replaced,
Installed an existing is installed to gain credit.
HRU, dedicated heat pump)
13-600.2.A.3.2 Additions Unable To Comply Alone.
Section 1)1.2.2 allows additions to either comply with the Code requirements for the addition
alone or by demonstrating that the entire building including the addition complies with the
Code requirements for news ued tbuildings. Sectionate.4.2.1 compliance. contains restrictions which shall
apply if the entire building
13.600.2.A.4 Multifamily occupancies.
13.600.2.AA.1 Common Conditioned Spaces.
Common conditioned spaces occurring in multifamily buildings that are not part of specific
tenancy units, such as corridors, lobbies, recreation rooms, offices, etc., shall be calculated
using one of the following procedures. percent (5%) of
1. No energy use calculation is required for common areas if less than five
the building area is used for such common areas.
2. Corridors, lobbies and similar areas shall be calcstructure such ulated using Chapter 4.
t 3. Non -reins shall be calculated nt accordance wimultifamith Sub chapter 4.
as cafeterias, offices,
and gyms
13.600.2.A.5 Worst Case Calculations.
ich are identical in configuration, square footage, and building
Residential occupancies wh
comply with the Code by performing a a worst case calculation. When
materials may P Y copies peof rform
Form 6o0A shall besubmitted referenced
submitting worst case calculations, cop
with each set of plans, dependent on the requirements of the buildingdepartment.
13.600.2.B Performance Calculation Procedures for Method B.
No performance requirements exist for Method B.
13-600.2.0 Performance Calculation Procedures for Method C.
No performance requirements exist for Method C.
13.600.3 Certification of Compliance.
13,.600.3.ABC.1 Code Compliance Preparation.