Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R40517 SI /� FLORIDA ENERGY EFFICIEN F pV�.3„kJ'� G CONSTRUCTION Florida Department of Business and Professional Regulation- Reside rfo mance Method RECEIVED Pmject Name: NLke Goodner Residence Budder Name: Street: i 5025 Emerson Ave. Permit Office: LSTLucieOwner 2018 LCoun�y, City, Stale, Zip: FL Pierce, FL. 34951 Permit Number Mrke Goodner - Jurisdiction:ermlEElnO Design Location: FL, Fort Pierre County St. Lude (Florida Crenate Zone 2 ) 1. New construction or existing New (From Plans) 9_ Wall Types(1056.0 sgfL) Insulation Area 2- Single family or multiple family Single famly a. Concrete Block - Int In'sul, Exterior R=4.1 1056.()0 ft b_ WA R= IF 3. Numberof units, 0 mulWe family 1 i c. WA R= W 4. Number of Bedrooms 2 d- NA R= 112 5_ Is this a worst case? • No 10. CeTimg Types (10880 sgfL) Insulation Area a. CalhedialfSingle Assembly (Unvented) R=0.0 1088.00 fr 6. Ciinrtilimed floor area above grade (ft� 1088 b. WA R= IF Conditioned Door area belowgrade (ft') 0 c. WA SCA ® IF 7. Wmdows(149.0 Description Area 11_ Ducts fN BY sgft.) a. Sup: Main, Ret Main. AH: Main 6 217.6 a. U-Factor. Dbl,default 149.00IF St Lucie County SHGC Clear, default b_ U-Factor. WA 111 12 Cpofing systems kBtulhr Efficiency ' SHGC: sa- Central Unit 18.9 SEERIS.00 c U-F,ador WA 0' SHGC • 13. Heating systems kBtuthr Efficiency d. U-Factor. WA fK a_ Electric Heat Pump 18.9 HSPF:9.00 SHGC Area Weighted Average Overhang Depth: 4.450 R Area Weighted Average SHGC: 0.700 14. H91 water systems a. Electric Tanldess Cap:7 gallons .8. Floor Types (1W8.0 sqR) Insulation Area EF: 0.920.920 a. Slab -On -Grade Edge Insulation R=0.0 1088.00 tP b. Conservation features _ b. WA R= IF None a WA R= ft= 15. Credits CF, CV, Pstat Glass%Floor Area: 0.137 Total Proposed Modified Loads: 47.52 PA�+S PASS., Total Baseline Loads: 47.65 !, I hereby certify that the plans and specifications covered y Review of the plans and S741� this calculation are in corn nce with the Florida F�he Code_I specifications covered by this calculation indicates compliance Of'IHE tic n e a pA with the Florida Energy Code. PREPARED[ Before construction is completed m DATE: this building will be inspected for compliance with Section 553.908 '_IEwI A »mot r I I hereby certify that this building, as designed, is in compliance Florida Statutes.. with the Florida Energy Code. G'0 WE OWNER/AG% BUILDING OFFICIAL: I/'? DATE: 4K DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -seated in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.90 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSURESNET11CC 380, is.not greeter than 0.030 On for whole house. 8/1l2018 6:48 AM Energ"yGauge® USA SectionR405.4.1 Compliant Software Page 1 of 4 a FORM;R405-2017 INPUT SUMMARY CHECKLIST RFPnRT PROJECT Title: Btddirtg Types Owner Name: # of Uri Builder Name: Permit Office: Jurisdiction Family Type: New/56 frog: Comment I Mke Goedner Residence Bedrooms: 2 User Conditioned Area 1492 Nike Guodner Total Stories: 1 1 Worst Case_ No Rotate An91c 0 Cross Ventilation: Yes Whole House Fan: No Single-famly New (From Plans) Address Type. Street Address Lot # Blo WSubdwtsios PlaBook: Street 5025 Emerson Ave. County_ St Lucie City, State. rip: FL Fierce, FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 25 % Int Design Temp Heating Design Daly Temp Winter Summer Degree Days Moisture Range FL, Fort Recce FL VERO BEACH —MUM 39 90 70 75 299 62 Low BLOCKS Numbdr Name Area Volume 1 Blodcl 1088 8704 SPACES Number Name Area Volume Kdchen Occupants Bedrooms Infii ID Finished Coded Heated 1 Main .1088 8704 Yes 1 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 SIab-On-Grade Edge Insulatio Main 133 ft 0 1088 W _ 0 0 1 - ROOF _ / V # Type Roof Gable Roof Materials Area Area Color Fs Solar SA EmAl dB Deck Pitch Absor. Tested Tested Insd. (deg) 1 Hip Composition shingles 1178 fL2 0 f12 Medium 0.96 No 0.9 No 20 n6 ATTIC / V it Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full aroic Unvented 0 1088 fl2 N N I CEILING # CeSmg Type Space R Value Ins Type Area Framing Frac Truss Type 1 CaOredallSingle Assembly(Umrented Main 0 Blown 1088 ft= 0.11 Wood 8/4/2018 6:48 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 _ - I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Ad)acent Spate Cavity Width Height Shealhing Framing Solar Below 1 N Exdedor Concrete Block- Int Instil Main 4.1 32 8 0 256.0 ftz 0 0.75 0 2 I S Exterior Concrete Block- kit Insul Main 4-1 32 a 256.0 fP 0 0.75 0 —3 E Exterior Concrete Block- Int btsut Main 4.1 34 8 272.0 ft' 0 0.75 0 —4 I W Exterior Concrete Bkxrk- Im Inst Main 4-1 34 8 27z0 ft' 0 &75 0 DOORS # Omt Door Type Space Storrs U-Value Width Height Akea R In Ft In 1 E Insulated Main Metal _46 3 6 8 20 ft WINDOWS Orientation shown is the entered. Proposed orientation. / Wall Overhang . V # Omt ID Frame Panes NFRC ll-Factor SHGC Imp Area Depth Separation- Int Shade Screening 1 N 1 Vinyl Double (Clear) No 0.55 0.7 Y 275 ft' 2 ft 0 in 1 It 0 in Drapesibrmds None 2 N 1 Vinyl Double (pear) No 0.55 0-7 Y 18.0 IF 2 ft 0 in 1 Rill in Drapeslblinds None 3 S 2 Vinyl Double (Gear) No 0S5 0.7 Y 18.0 ft- 2 ft 0 in 1 It 0 in Drapeshilmds None 4 i S 2 Vinyl Double (Clear) No 0.55 0.7 Y 9.0 IF 2 ft 0 in 1 ft 0 in Drapeslbfinds None 5 E 3 Vinyl Double (Clear) No 0.55 0.7 Y 275 il= 12 ft 0 in 1 ft 0 in DrapeslhGnds None 6 E 3 Vinyl Double (pear) No 0.55 0-7 Y 9-0 IF 12 ft 0 in 1 It 0 in Dmpes/bPmds None 7 W 4 Vinyl Double (Clear) No 0.55 0.7 Y 36.0 ft2 2 It 0'in 1 It 0 in Drapes/blinds None, 8 W 4 Vinyl Double (Gear) No 0.55 0-7 Y 4.0 IF 2 ft 0 in 1 ft 0 in Drapesibrrnds INFILTRATION # IPe Method SLA CFM 50 ELA EgLA ACH ACH 50 �• " 4 Whoti house Proposed CFM(50) .0003 8562 47 88.39 2174 5.9018 HEATING SYSTEM # System TYPO Subtype Efficiency Capacity Block Duds 1 Electric Heat Pump/ None HSPF_9 1&9 kBhA r 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flaw SHR Block Duds 1 I Central UruV Plane SEQt 15 1&9 kBbAy 567 cbn 0-72 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use Seh"nt Conservation 1 Electric Tankiess Main 0.92 1 gat 50 gal 120 deg None 8/4/2018 6A8 AM EnergyGauge® USA Section R405A.1 Compliant Software Page 3 of 4 FORM R405-2017 INPI IT -I IMMARV r_FIF(_KI MY RFPnPT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model If Area Volume FIEF (None None ft' DUCTS J —Supply— —Return— Air CFM 25 GFM25 HVAC# 1# Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF Heat Cool ,1 Main 6 217.6 ft Main 54A ft- Prop. Leak Free Main — ctm 326 chn 0.03 OM 1 1 TEMPERATURES Programahl�[e Thermostatt]JY CEeiling Fars: JJan eb [��J]Mar f] �(JfJun Jul[[X]J � [�XJJ �Jj [�7��] ee [�]J Venfmg L 1 L J L^1 Mar L�1 A .l JM 11 Jrimm id L 1 �9 L J� LN O Lxl NO l 1 DM ThermostatISchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooffn tW 78 80 I IPM 80 go 8 8 78 78 78- 7788 8 8 8 Cooling (WEFT) 78 788 78 I PM 7 7 7 78888 7 7 7 78 78 78 78 Heating (WO) 66 68 66 68 68 68 PM 665 8 68 6688 68 6688 68 6B 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 - PM 68 Ga 68 68 68 68 68 68 68 68 66 66C, MASS Mass Type Area Thidmess Furniture Fraction Space - Defaul 8 PwisclfL 0 iP 0 ft 0.3 Main Name: Rating Compant: Signature: Date:ZA;' 8/4/201 a 6:48 AM EnergyGauge® USA Section R40.5.4.1 Compliant Software Page 4 of 4