HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
- FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE HE GRAND CA. RLTON
Builder Name: WYNNE BUILDING COPR.
Street S `..�� �,\"n`�2f
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner. WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft'
b. Frame - Wood, Adjacent
R=11.0 192.00 ft'
3. Number of units, if multiple family 1
c. NIA
R= ft'
4. Number of Bedrooms 2
d. WA
R= ft'
10. Ceiling Types (1446.0 sgft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1446.00 ft:
6. Conditioned floor area above grade (ft= 1446
b. N/A
R= ft'
Conditioned floor area below grade (W) 0
c. N/A
R= ft'
11. Duds
R ft'
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor. Sgl, U=0.36 101.25 ft'
SHGC: SHGC=0.25
SCANNEI1tu/hr
65
b. U-Factor: Sgl, U=0.65 40.00 ftz
12. Cooling systems
Efficiency
SHGC: SHG6=0.21
a. Central Unit BY
34.8 SEERA5.00
c. U-Factor. " WA ft'
St Lucie County
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. WA ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1445.5 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft'
b. Conservation features
b. WA R= ft'
None
c. WA R= ft'
15. Credits
Patel
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.18
PASS
Total Baseline Loads: 48.09
1 hereby certify that the plans and specifications covered by
Review of the plans and
4-fHt; STq�
this calculation are in compliance with the Florida Energy
specifications covered by this
y0 60�
Code.
calculation indicates compliance
r
with the Florida Energy Code,
is nn, •,; ,",:,`';:,,,• „ O
PREPARED B
Before construction is completed
O
DATE: 4k`(
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
�'Op WE f40
OWNER/A F T:I C -
BUILDING OFFICIAL:
DATE: � GA I- C
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
IL
11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY GHEGKLIST KEPUKI
PROJECT
Title:' WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
,
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infi11D Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M. BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 It 0
301 ft'
—
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft'
—
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft'
—
0 1
0
4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0
192 ft'
—
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft'
_
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 It 0
203.5 ft'
—
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0
55 ft'
___
0 1
0
11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft'
--
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft
0
488 ft'
-
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft'
240 ft'
Light
0.6
No
0.9
No
0
18.4
ATTIC
/
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft'
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft'
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft'
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft'
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft'
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing
Solar
Below
Space
it Ornt TO IMP11 Type
1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM
4.1 10
0 8
0
80.0 ft'
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext Insi3EDROOM
4.1 28
0 8
0
224.0 ft'
0
0
0.6
0
3 NW=>SE Exterior Concrete Block- Ext Ins®EDROOM
4.1 14
0 8
0
112.0 ft'
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft'
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.6
0
_ 6 NE=>SW Exterior Concrete Block - Ext InfffDROOM 2
4.1 16
0 8
0
128.0 ft'
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext InfiffDROGM 2
4.1 10
0 8
0
80.0 ft'
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext InfiEDROOM 2
4.1 4
3 8
0
34.0 ft'
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext In!flffDROOM 2
4.1 2
0 8
0
16.0 ft'
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft'
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsaAUNDRY
4.1 6
0 8
0
48.0 ft'
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsDREAT/DINI
4.1 26
0 8
0
208.0 ft'
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext Ins3REAT/DINI
4.1 20
0 8
0
160.0 ft'
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft'
0.23
0.6
0
11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
# Omt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
# Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
_ 4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.36 0.25 N 32.9 ft' 1 It 0 in 1 ft 4 in
0.36 0.25 N 6.9 ft' 1 It 0 in 1 It 4 in
0.36 0.25 N 24.0 ft' 6 It 0 in 1 ft 4 in
0.36 0.25 N 37.5 ft' 1 ft 0 in 1 ft 4 in
0.65 0.21 N 40.0 ft' 8 ft 0 in 1 It 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor. Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft'
316 ft'
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356
1349.6 74.09 139.34 .2578
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit!
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
11/8/2018 3:28 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
DUCTS
— Supply --
—
Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic
6 250 ft'
Attic
65 ft'
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programablre'Thermostat:
Cfreiling Fans:
,]Y
Heat ng Jan Feb
[[ ]]
[X] Mar
AApr
May
�X]
[ ] Jun
jXj
] Jul
[X]
] Aug
[X]
[) Sep
[ j [[X]] ov
L J Oct Nov
Dec
Dec
Venting III 111 Jan [[[ 111 Feb
L l l l
[[�xll Mar
[
[)Jun
E )Jul
E )Aug
[)Sep
Lxl [X]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM
Default(81bs/sq.ft.
fP
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft'
it
0.3
BEDROOM 2
Default(81bs/sq.ft.
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 Ibs/s .ft.
ft'
ft
0.3
GREAT/DINING
Name: Test Rater
Rating Compant: Test Rater
Signature:
Date:
11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
w
x
Design Location: FL, Fort Pierce
�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
! Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
•
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
=Mpla= mpg 4alls or
a. In addition, inspection of log walls shall be m accordance wRh the provisions of ICC-400.
11/8/2018 3:28 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1.
New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts
R
6.0
2. Single-family or multiple -family
2.
Single-family
b) Return ducts
R
6.0
c) AHU location
Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system:
Capacity
34.8
a) Split system
SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package
SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room uniUPTAC
EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.442
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.239
14. Heating system:
Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump
HSPF
8.5
b) Single package heat.pump HSPF
8. Skylights
c) Electric resistance
COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas
AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG
AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
15. Water heating system
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
1081. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a. 30.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: /l Date:
Address of New Home: - v ^ - \ City/FL Zip: FT. PIERCE. FL 2"07�
r
111119/2018 3:04:39 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1