Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
wrightsofto Project Summary new , Entire House By: QUICK CALCS, INC. For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: SCANNED BY St Lucie County Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) ' Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration (Method Simplified construction quality Average (Fireplaces 0 Heatin Area (fta) 144b Cooling 1446 ;Volume (ft') 12511 12511 Airchanges/hour 0.45 0.23 Equiv AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 8.5 HSPF 34600 Btuh @ 470F 27 OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O point = 32 OF kW, Output = 23009 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 17520 Btuh. Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swingg multipplier 0.95 Equipmentsensibleload 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Canter Trade CARRIERAIR CONDITIONING Cond 25HBC53WO30 Coil FX4DN B;F)037 AHRI ref 79145 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360. Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �+ wrightsoft zon-Apr-11 as:e 1 RightSuite® Universal 207717.11.t4 RS1108101 Page 1 I...uick CalcMDocuments\THE GRAND CARLTON-0446.rup Calc=MJS Front Doorfaces: N FILE C Pv, + wrightsoft. Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 STP LUCIE LN., FT PIERCE, FL 34946 Phone: 772-4665799 Fax 772-466-6796 Emil: QUICKCALCS@AOL.COM .1 I Roomname Entire House BEDROOM 2 IRVosed wall 156.2 It 49.0 It 3 Room height 117 ft d 8.0 ft heavc0ol 4 Rocm dimensions 1.0 X 297.0 ft 5 Room area 1445.5 ft' 297.0 ft' Ty Construction U-x,4ue Or HTM Area (ftj Load Area Load number(Btuhfft;-F) or perimeter (ft) (Btuh) or perimeter, meter, (ft) (8tuh) Gross NIRIS Heat Cool Gross I N/P/S Hem Cod 6 f13"066_ '4A5-2onW 0.143 6 '211.66 255, '.19.31 503 .465 :W - 1862 - 1184 72, - --72 .288 183 13A-4ocs 0.770 0.143 n- o 4.00 2.55 128 83 :1816 333 :'730: 212 0:1 0 0 0 0 0 'O 0 IA-clom 1.2/0 a 35.66 87.29 24 2 848 2082 0 0 0 0 1 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 '13AAWS 0.143 • so 4.00 255 34 34 136 86 0 0 0 0 13AAws 0.143 a 4.00 255 360 353 1414 899 216 216 865 650 11Aclom 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 13A4&s .0.143 w 4,00 255 310 237 949 r 603 104 .72 288 183 �4'2191mm 1.270 - w 35.56 55.21 32 2- 1140, 1770 32 2 , 1140 1770 '0.77() W '121.56 '19.31 41 41 880 789 0 01 0 '1.-0 12C-Osw 0.091 - 2.65 C 192 192 489 246 C 0 0 0 T16430md 0.032 - .0.90 2.32 1446 .1446 11295f, 3354 ,297 297, '266 ;689 22A-Icl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 .)AED excursion 918 627 - Emelope loss/gain 14961, 13349 4204 4003 12 Is) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 1 1 Internal gains: Occupants @ 230 61 1380 1 31 690 Appliances/other 2000 0 I Bubtotal Dines 6 to 13) 17848 17620 5053. 4925 Less Wernal load 0 0 0 0 Less transfer 0 0 0 0 0 0 0 0 4 jecistribution ubtotal 17848 17520 5053 4925 15 uctloads 32% 49% 6654 85M 32%- 49% 160I 2400 al room Iced 23503 26056 6353 1 7325 required (cm) 11601 1160. 328 326 -P1j4- wrig . ht:soft* I Right-SufteOUniv mal2Ol7l7.0.14RSU08101 ... uIck Caics\Documents\THE GRAND CARLTON-1446.mp Calc,=MJB Front Door faces: N 2017-Apr.11 09:29:38 Page I wrightsoft' Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@ACL.COM. 1 Room name WIC KRCHEN 2 Bgmed wall O ft O ft 3 Room height 8.0 ft hewcool 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 It 1.0 x 1720 ft 5 Room area 54.0 fP 1720 ft' TY Cons�Wction U-value Or HTM Area (ft2) Load Area (ft') Load (BtuWftk-F) (BluIvW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool _Gross WP/S Heat Cool . 6 -- 13.4-0acs. ' - �4AS2om - 0143 "-:n '4.00 255 0 0 0 - -0 0 0 0 ', 0 I_G- ` 0.770 -°n -21.56 ' 19.31 " ' 0 " .. 0 - 0 ,0 0 " -0 0 - 0 Vjl 13A-0acs 0.143 a 4.00 2.55 0 .0 0 0 0 0 0 0 (L 1Aclom 1.270 a 35.66 87.29 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W' - 13A4ocs 0.143 se 4.00 265 0 0 0 0 0 0 0 0 W 13AAccs 0.143 s 4.00 255 0 0 0 0 0 0 0 0 1Ac1crn 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 1 163A-0ccs 0.143 w 4.00 2.55 0 0 0 .0 0' . 0 0 0 1Acio01. 1,270 w '35.56 55.21 0 0 0- 0 0 0' 0 0 4A5-2om .0.77O w 21.66 19.31 0" 0" 0 0 0 0. 0 '0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 IC .- j16A30md' 0.032 - 0.90 232 54.... 64 - 48 - 125 - -172 172 154 399 F 22A-tol 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 61 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltratio0 0 0 0 0 b) Room ventilation 0 0 '0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49% 100 1126 Total room load 64 174 1 418 3437 Air required(cfm) 3 8 21 153 -FIt wrigill RlghtSuite@ Universal 2017 17.0.14 RSU08101 ...ulck CalcslDocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Doorfaces: 2017-Apr-11 09:29:38 Page 2 wrightsoft Right-JO Worksheet Job: Entire House Date: sy. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466.6799 Fax 772-46"796 Email: OUICKCALCS@AOLCOM 1 Room name BATH BEDROOM 2 2 F)Posed wall 5.0 ft 34.2 ft 3 Room height 8.0 It heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 5.0 It 1.0 x 203.5 ft 5 Room area 45.0 ft- 203.5 W Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (StulUft-F) (BtalVft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 1 '13A4om _ - 0.143 It 4.00 255 40 40 160 102 128 128 513 ' 326 4A5-2= ,". .0.770' It %21.56 19.31. - 0 0, 0 ..0 b 0'' 0 0 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 80 56 225 143 I--G 1Ac1cm 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 II -DD 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 w 13A4ccs 0.143. se, 4.00 2.55 0 0 0 0 34 34 136 86 lM 13A-4ocs 0.143 s 4.00 255 0 0 0 0 32 32 128 81 Y-C 1Aciom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 tat 13A-4ocs 0.143 w 4.00 255 0 0 0 0 0 0 0.` 0 1Aclom 1.270 w 35.56 55.21- 0 0 0 0 0 .0 0' 0 4A5.2On , •0.770 w 21.56 19.31 • 0 0 a 0 0 0 0 0 P 1200sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 IC ''_1WOmd.. '- - 0.032 - .0.90 :. 2.32 45 45 40 104 204, 204 182 472 F i .' .t .' 22A-tpl 0.989 - 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED emursion -16 -65 Envelope lass/gain 339 190 2978 3106 12 a) infiltration 87 24 693 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (Ilnes 6 to 13) 425 214 3571 3498 Less mdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 32°(a 4S% 135 104 321/6 49% 1131 1704 Total room load 560 318 4702 5203 Airirequlred (cfm) 28 14 232 232 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft• Right -Suite® Universal 201717.0.14 RSU08101 2017-Apr-11 0 Page 3 ...ulck CalcsWocuments\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N wrightsoft' Right-M Worksheet Job: Entire House Date: sy. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 7724666799 Fax 77246M796 Email; QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREATIDINING 2 E gmed wall 6.0 it 47.0 ft 3 Room height 8.0 ft heat/cod 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 It 420 ft2 1.0 x 626.0 ft 526.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ftj Load number (Btub1ft�*F) (Btul✓ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Coal Gross N/P/S Heat Cool Gross NIP/S Heat Cod 6vlf, 13X4ccS- 5r ?9A5-20m ".0143 -.n'. : 4:00 r 2:55 0=. 0. 0 ' :'0 '% 255 ' 217' •869 ', .552 ILL", ,4y - 13A4ocs 0 770 0.143 n' a 21:56 4.00 19.31 265 ' . . 0 0 , 0 0 0 0 0 0 38 0 '- . 0 0 815 0 ' 730 0 11 I�----GD 1Aclom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W W I--G '13A-4ocs 13A4ocs 1Acl m 0.143 0.143 1.270 as s s 4.00 4.00 35.56 265 2.55 34.77 0 48 0 0 48 0 0 192 0 0 122 0 0 0 0 0 0 0 0 0 0 0 0 0 I 13/44acs .0.143 w 4.00 2.55 0 0 0 0 206 165 661 420 1Ai1om -4AS-2an1 1.270 w 35:56 ... 55.21 0 0 0. 0 0 r0 .0. .0 P _ jC 12C-0sw 16A30md 0.770 0.091 0.032 w - - 21.56 255 0.90. 19.31 1:28 2.32 0 56 42 0 56 42 0 143 38 - 0 72 ,. 97, 41 0 _ .526 41 0 526, ' 880 0 ' ...'471 '788 0 ,'. ;1220 �F 22A4pl 0.489 27.69 0.00 42 6 166 0 526 47 1302 0 6 c)AED excursion -22 668 Envelope loss/gain 639 270 4997 4379 12 a) Mitration 104 28 997 273 b) Roomved9ation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Applianceslother 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 Less 0 a I load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotd 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 2490 Total.m load 846 443 7892 76D2 Airrequired(ofm) 42 20 390 338 . erF �i- wrightsof!- Right -Suite@ Universal 2017 17.0.14 RSUD8101 2017 Apr 11 OPage 4 ...uick Calos\DocumentslTHE GRAND CARLTON-1446.mp Colo = MJB Front Door faces: N wrightsoft, RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE L(1, FT. PIERCE, FL 34946Phone: 772466.6799 Fax 772468-0796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 Exposed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaticool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft ' 5 Room area 50.0 fP 56.0 W �Ty Construction U-value Or HTM Area number (Btuh/fR°F) (Muhl" or perimeter (ft) (Btuh) or perimeter (ft) (BtLoaduh) Heat Cool Gross WP/S Heat Cool Gress WP/S Heat Cool 6 W :.13A-0ocs 0143 -n :4.00 255 8-'• 8 32 20 0. 0 u 0 I-r':4A5-2om:'-. .0770 n .21.56 19.31 .`0.. .0 0. .. 0 0 - 0 - 0 _0 13A-0acs 0.143 a 4.00 255 48 27 108 69 0 0 0 0 1Ac1cm 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 w .13A-0acs 0.143 se. 4.00 255 0 0 0 0 0 0 0 - 0 4)/ 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 64 57 228 145 I-_, 1Actom 1.270 a 35.56 34.77 0 0 0 0 7 7 247 241 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.56. 55.21 0 0 0 0 0 0' 0' .0 -4A5.2cm ^'. 0.770 .. w 21.56 :: 19.31 0 0 . 0 .0 . 0 0 0 0 P, 12C-0sw 0.091 2.55 1.28 72 72 183 92 0 0 0 0 C .16A30md. 0.032 - 0.90 2.32 50' 60 45. 116 56 .53 .r.60 ,130 F i �G' 22A4pl 0.989 - 27.69 0.00 50 - 7 194 0 56 8 - 222 0 6 c)AED excursion -39 -8 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 8) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (Ilnes 6 to 13) 913 529 885 616 Less eAemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtatal 913 529 885 516 15 Duct loads 32% 49% 289 258 32%1. 49% 280 251 Total romn load 1 1202 787 1 1 1166 768 Alir recluned (cfm) 59 35 58 . 34 � -FV- wrightsoft- Right -Suite@ Universal 2017 17.0.14 RSU08101 ...uiek CaleslDocumentsME GRAND CARLTON-1446.mp Cale a MJ8 Front Door faces: N 2017-Apr-11 09:29:38 Page 5 wrightsoft® Duct System Summary Job: Endre House By: QUICK CALCS, INC. 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-466-6796 Email: OUICKCALCSQAOLCOM Far. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating, 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100it 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 elm 176 ft Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (In) H x W (In) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 OxO VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 st2 ` FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 -KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 OxO VIFx 0 0 wlc C 174 3 8 0.309 4.0 OxO VIFx 27.0 135.0 st2 Trunk Htg Clg Design Veloc Diem H x W Duct Name Type (Cfm) (Cfm) FR (fpm) (1n) (In) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx & 9 wri htsoft, 2017-Apr-1109:29:38 AOCi\RightSeReG Universal 201717.0.14 RSU08101 Page 1 ...nick CalWDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N _,,�: ..- r :� r i°„ Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (Cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Mad Trunk rb1 OxO 1160 1160 0 0 0 0 Ox 0 VIFx y:F;Fi"t 2017-A r ll 09:29:38 rt wrightsoft' RightSuite® Universal 2017 17.0.14 RSUD8101 p Page 2 )CC&...ulck Celcs\Documents\THE GRAND CARLT014-1446.mp Calc = MJ8 Front Door faces: N