Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTRUSS PAPERWORKD�ninnf /nfn�rn�iinn•
t
SOUTHERN
TRUSS
COMPANIES
Southern'Truss
2590 N. Kings Hwy
Fort Pierce, FL 34951
(772) 464-4160 * Fax: (772) 318-0015
Job Number. ••••�••••�••�•••
J1800496
Customer.
Ryan Homes
Name:
Oakland Lake - Lot 61
Address:
6275 Oakland Lake Circle
City, ST, ZIP.
Fort Pierce, FL 34951
General Truss Engineering Criteria & Design Loads
Building Code and Chapter.
FBC2017/rP12014
Computer Program Used:
MiTek Version: 8.23 Oct 2 SCANNED
Gmviv.
GraviW: BY
37.0 psf ROOF TOTAL LOAD
N/A
Wind
Building Authodty:
160 mph from MWFRS(Envelope) ASCE 7-10 (Low Rise)
St. Lucie County
This cover sheet is provided as per Florida Statute 61G15-31.003 in lieu of signing and
sealing each individual sheet. An Index sheet of the truss designs is attached which is
numbered and with the indentification and date of each drawing.
No., Engineer of Truss Design Package
7,. ,k � • Q = Brian M. Bleakly
Of, ; W FL Reg. Eng. No. 76051
ST0.TEtA•�: _; 2590 N. Kings Highway
Fort Pierce, FL 34951
No.
Date
Tmss ID#
1
11/14118
Al
2
11114/18
A2
3
11/14/18
A3
4
11/14118
A4
5
11/14/18
A5
6
11/14118
A6
7
11/14118
A7
8
11/14118
AS
9
11114/18
A8G
10
11114118
B1
11
11/14/18
B2
12
11/14/18
B3
13
11/14/18
B4G
14
11/14/18
c1
15
11/14/18
C2
16
11/14/18
C3G
17
11/14/18
Cis
18
11114/18
CJ7
19
11/14118
J1
20
11/14/18
J2
21
11/14/18
J3
22
11114118
J4
23 1
11/14/18
J5
24
11/14/18
A
25
11/14/18
J7
26
11/14/18
J58
27
11/14118
MV2
No.
Date
Tmss Io#
28
11/14/18
MV4
29
11/14118
MV6
FILE COPY
Page 1 of 1
TYPICAL DETAIL @ COR.NER. - HIP
y NOTE: NDS=National Design Specifictions ALLOWABLE REACTION PER JOINT
for Wood Construction_
QA UP TO 265p = 2-16d NAILS REO'0.
132.5# per Nail (D.O.LFactor=1.00)
nds toe nails only have 0.83 of UP TO 394# = 3-16d NAILS REO'0.
'lateral Resistance Value.
. _ 12 �n SCA) Sn
CORNER JACK GIRDER
2
use 2-16d
toe nail
TC & BC.
Typical jack 45' 1- -
attachment use 3-16d\
toe nail 0 TC
TYPICAL CORNER LAYOUT & ?-16d RJ
Typical Hip -jock'
attachment
CHORD
HANGERS
FASTENER
GIRDER
JACK
J1-J3 TO HIP JACK GIRDER
TC
- - - - - - -
2-16d nails
- - - - -
BC
- - - - - --
2-16d nails
-----
J5 TO HIP JACK GIRDER
TC
- - - - - - -
2-16d nails
- - - - -
BC
- - - - - --
2-16dnails
-----
J7 TO HIP GIRDER
TC
- - - - - - -
3-16d nails
- - - - -
BC
- - - - - --
2-16dnoils
-----
HIP JACK GIRDER (CJ7) TO HIP GIRDER
TC
- - - - - - -
3-16d nails
- - - - -
BC
- - - -- --
I 2-16d nails
----
SOUTHERN
TRUSS
COMPANIES
IR¢e/%nrsoulhenhimmm
Brian M Bleakly Struct Eng #7
MINIMUM GRADE OF LUN
T.C. 2z4 SYP $2
B.C. 2:4 SYP 2
WEBS 2a4 SYP No3
LOADING
(PSFy
�- U'�
L
O
FeQan
TOP
20
BOTTOM
DO
10
SPACING
24
0.1
Fort Pierce Division
2590 N. Kings Highway,
Fort Pierce, FL 34951
(800)2F 2-0509 x:(772)318 20-4160
06fi
1 2590 N. Kings Highway, Ft Pierce, FL 34951 772-464-4160
TYPICAL DETAIL @ CORNER - HIP
NOTE NDS=National Design Specifictions
for Wood Construction.
132.5# per Nail (D.d.LFactor=1.25)
nds toe nails only have 0.83 of
lateral Resistance Value.
12
1OVER .o
12
OVER
�� 9b
—0-14
CORNER JACK GIRDER
10
ALLOWABLE REACTION PER JOINT
UP TO 265p = 2-16d NAILS REQ'D.
© UP TO 3941 = 3-15d NAILS REQ'D.
use 2-16
toe nail B
TC & BC.
Typical jack 45'
attachment
X3-
i
H5 (HIP GIRDER)
N
,
use 3-16,
toe nail
TYPICAL CORNER LAYOUT & 2-16d
Typical Hip —jock'
attachment
CHORD
HANGERS
FASTEN ER
GIRDER
JACK
J1—J3 TO HIP JACK GIRDER
TC
— — — — — — —
2-16d nails
— — — — —
BC
— — — — — ——
2-16dnails
—————
J5 TO HIP JACK GIRDER
TC
— — — — — — —
2-16d nails
— — — — —
BC
— — — — — ——
2-16dnails
— — ——
TC
— — — — ——
3-16dnails
— — — — —
BC
— — — — — ——
2-16dnails
—————
HIP JACK GIRDER (CJ5) TO HIP GIRDER
TC
— — — — — — —
3-16d nails
— — — — —
BC
— — — — — ——
2-16dnails
— — — —
MINIMUM GRADE OF LUMBER LOADING L (PSF) STR INCR- 2sz
FBC2017
T.C. 2x4 SYP #2 D
TOP. 20
B.C. - 2x4 SYP 2 BOTTOM D0 10
WEBS 2x4 SYP No.3 SPACMG 24' D.C.
SOUTHERN
Fort Pierce Division
TRUSS 2590 N. Ki,gFLHiyyhwa ,
FortCOMPANIES (BDO)232-0509 (772)464-4160
h6#//. xoumermtn,sswm Fax:(772)318-0016
Brian M. Bleakly Struct Eng #76051 2590 N. Kings Highway, Ft Pierce, FL 34951 772-464-4160
I J
Hangers•
Face Mount Hanger Charts M ITe V
JoistSrve
`. IJSP
Stoukft -
._
Ref. Na
Steel
Range
....
F2.tietierSched �
OF1SP
fd wale Lwds(Ws.)t
-
c '.ft
-. Rudel.
-. .Inisd ..
_-
. l9
H
-
-0
.'.
q °
Tl9N
T1az
-
.Nail
0
_
DaU
Rnm
100%
Roof 4ow
JL24
W24
20
1-9/16
3
1-12
15/16
-
4
1 1Dd
12
I tAdxt-12
:470I
54O i 580.I 320 .
5
R5, F2
4
15d
12
1 10d x 1-12
560
1141 1 695:I 320
JL241FTZ
-
18
1.9/I6
bt/B
1-12
-
_
4
1ad HDG
2
1Gdxl-12HDG
465
535 I SBO � 280.
I 31. Rt,
F32
4
16d HDG
2
110d x 1 V HDG
. 550
615 ( 815 2B0 -
2x4
JU524
WS24
18
1-9/16
3-1/B
1-3/4
1
4
lad
2
1Dd
"Qli-
7751 WS 510.
SIM24
U24
16
1-9/I6
3-1/4
2
1-3/16
-
4
lad
12
ladxt-12
:500
j.5601 605 I 380
5,
4
166AA-
10dxl-1/2
-590
6651720, 380:
HB26
HU26
14
1-9116
bit
2-12
1-1/8
�0
4
16d10d
x1-12
695 746 365
R5,
F2
Max
.SiS
615
fi95 1 745'I r%%
.JI-7B -
11126..
20•
1-9I16-
:4-3/4
-f72
15pS
�-
6
.:'lad10dx112;
710
805 j 870 �) 650
6
-.16d
4 1
10ds 1-12 •
' 840
1 95D j 1D45 650
�'�,R26R-TZ
'
WC26Z
-
"IB
1-9/16
4-12-
1=12
_ '
6:'10dHDG
.4 '110dx
7=12HIM
695
800- 870'.1 73g
31, R1,
F32
6:
76dHDG
j. 4-j10dx1-MlMi
830I950
.1035 730
-JI1526 „ .:1
W526 -1
.18
I1-9/16
4-'13I76
}374
1=. 7-'
.4 '
' ^ 11 -j
' 4 .
'I ad : -
I .9M
1000'. 1030 11115
4 5. R5, F2
'-:Nlum.
-1B ':
13gfi1'S-tllfi-
-.2-'
-. 7.r.
='
g,
': ]Gtl .j.5'r,
1pd.': -.I
1285
147511605 j. 865-
37, R7, 132
SIM?Ii
t'
J126-
-
16
1-9/16
3-7/B
-_2
,....3
_-
13r16
. =
6.1
-10d
14
F 10d xl=12 .
750
840I 9_a1 `755'
>6 -
-^16d
1 4
1-.-10W-12-.
'880
1 10001 MCI I 755
- .'.:.
1NS1B'- ...
HU526 {
16'.
1.518
•'S-7A6-
2
-14-
161...
1.6
1: "16d .
2760I
3140 ! 33451 1925
I
HDZ6
HU26
14
1-06
3-12
2-172
1-4/8
M10
4
ii '"16d
.2
10dz1-72
t 615
( 6%1 745 3FS:-
5,
R5,
G15-
695 1 .745 I 595
-
HD28
HU7B
]4
-
1-9116
SAM
.2-12
1.1/8
Mn
8 •.
"16d
4
i - 10dXI -12
1730
139011490 780.
f2
Max
6
1230
1390'I 1490 825
JL2"6
LU26
20
1-9h6
4-3W
1-12
1516
-
6
10d
14
I 1Od xt-12
710
805 ) 970.1. 650.
6
l6d
4
1 lOd x t-12
960 j 1045.1 650'.
JL261F-TZ
WC26Z
18
1416
4-12
1-12
-
_
6
lad HOG
4
110dz1-12 HDG
695
I Soo 1 9'70 730
31, In.
I F32
6
16d HDG
4
1ad x 1-12 HDG
--830
9% 1035 7W
Jt28
LI728
20
1-9116
6318
1-12
15/16
_
10
10d
6
.10dx1-12
1180
1295I 1295 855 .
S. R5 F2
10
t6d
16
10d x 1-12
1400.
160111740I 855
JL2MF-TZ
-
18
1-9116
6-1/8
1-12
-
_
8
lad HDG
4
tOdzt-12 HDG
.i93g
106511160.I 730.
I 31, R1,
F32
8
lad HDG
4
10dx1.12HDG
1105
121511215 730
JU526
LLS26
18
1-M6
4-13g6
1-3/4
1
-
4
10tl
4
100
870
1009T ian .1115
JUS28
itICMA
18
1-9M6
6-58
MM
1
6
lad
4
10d
111D
1270 1375. 1115
? S, IIS, F2
2xB
MUMS
MUS26
18
1-9/16
5-1116
2
1
-
6
lad
6
lad
'1285
147511605 865
31. R1,
MUS28
mum
is
1-9/16
7-7/I6
2
1
8
lad 18
lad
'1710
1970;31401 1230
F32
SUH26
U26
16
1-9/16
5-18
2
1-3116
-
6
lad
4
lad x1-12
:7501
840.1 S101 755'
6
16d 14
lad x 1-12
880 1
10MI 10M 1 755 -
SUH28
-
16
1-9/16
6-5/8
2
1.3116
-
8
lad
6
lad x1-12
1000
112011210. 800
8
16d
6
10d x 1.12
1175 j
1395 1440 Boo
HUS26
HM26
16
1-58
5-7/16
3
2
-
14
tad
6
16d
276013140
.3345 1925
5,
HlLS79
IM28
16
1-SB
7-3116
3
2
-
22
16d
8
t6d
4170 14345
143451 2570
fly
HD28
HU28
14
1-9/I6
5-1/4
2-12
1-1/8
Man
8
lad
4
lad xt-12
•123D
1390.j 1490 780 j
F2
Max
6
'1230
1390j 149DI 825
HD210
HU210 '
14
1�Y16
7-3h6
2-1/2
1-1/8
MN
10
lad
4
10dx1-12
1540 117351
1865 780
Max
14
6
2155
2430 2610.1 1170
1) Upg4 bads have been increased 60%fte v4nd rcseenic loads, no further inrsea,e stag be permitted
2)16d strikers (0.148 da. x 3-1/4' long) may be used at 0.84 afthe table load where 16d commons are specified. Ttds does nut applyto MS, NUS, MUS slant hall hangers.
3) For JUS, HI1S, and MM hangers Nails must be driven at a 30-tn 45' angle mreugh thelast or trust hW the header/a achieve thetable loads
4) NALS.-10d x 1-12' nails are 0.148' die. x 142' long, tad r" are 0.148" die. x 3' long, l6d ralls are 0.162' da. x 3-12' long.
New products ar updated product information are designated in blue font.
Corrosion Rntsh OStainless Steel CGOId C/ot EHDG ETriple Zme
112 Continued on next page
Hanger's
Face Mount Hanger Charts
MiTek&
Joist sin
LISP -
- Stock No.
'
Ref. No.
. Steel'
Gauge.
Oimansions (in):
Fastchm&hedule''
.:. DF/SP
Allowable Loads(Lbs1'
�.
�' w
ff
LL
.
Ref:
Headw,
-,.Jaat
".
IN
•H
D
A
Nod
'Mai
:
Nair
�
: Nag
gaor,
1GD55
Hoof
115% 125%
Dpiiflr
160%
JUS24-2
WS24.2
18
3-1/8
13-7/16
2
I 1
4
( 16d
2
1 16d
I SD5
{ 9201
965
; 325
(2) 2 x 4
SUH24-2
U24-2
I 16
3-118
3-1/6
2
1-1/8
_
6
10d
2
10d
1 750
84
'
3B
6
16d
2
10d
.B80
100L101
1097800
I 3800 .
HB24-2
HU24.2
14
3-1/8
3-12
2-12
1-1/8
-V4.16d
2
10d
1.615
695
1 745
1 385
HUS24-2
-
14
3-1/8
3-7116
2
1
-16d
2
166
I.80
965
{ 10401
495 1
HUS24-2IF
-
14
3-1/8
3-7/16
2
1
-16d
2
16d
. 850
965
1 1 D40
1 495 1
- :
JUS26-2 "'
;LUS26-2:-" "{:'
18-
I,3-7/8'1
5-174'1
2
Y
-::16d
1 4
76d
11040
1785i
7220{
1355
SUH26-2
� U26-2 -.
16 ,
:34/8 .
5-1/16
- 2
1/0
_'
10
10tl �
4-.
10d<{
1250'
14051
15151
755
10
1 16d
-4 .
Intl
1470,
167D.
1Boni
755
40242 :. -
{: HU24-2
14.
( 3-1/8
{ . 3-72
{ 2-]r2
(1.1/B
= -
f .-4
1 '16d
1 2•
{ 10d
1615
1 695
745
1 385 i
(2J 2xfi..
-HUS26-2'- - :
HUS26 2 -'
14
3-1�7/4
•I 2
I 1
' 4 -1
16d
I 4._1
16d
1085
11235
113001
1155
......r
- HU526-2IF d ;. •1:HUSC26-2
+#'
14
. 3-1/8
{' --
-. :2
7.
. -;
P4 -.
16d :1.
.4
1 I6dl
1g85'
7235
L73011J
1155
�aTHU26-2
l
I _'14
iii
. 3-18'
5-1/4
2-1/2
1-1/8
Me
Max
I 8
112-
. 16d
-
4
"6
1 Intl
11230
( 1390
(1490
I 780 .
{ :c
18501
2085!
Z235
i 1770
-'.
H026-2ff "�HUC26-2
ur
�.'14"
3-1/8
'5-1/4
2-12.
'....
-`n
"Maxi
8
72
16tl `'.4
1
L.'s::..
{ Intl
.. :
1230.
1B5g
]39g114901
z085
2235
780
{. t170
I JUS26-2
I WS26-2
18
I 3-1/8
5-1/4
1 2
1
-
4
16d
4
16d
1 1040
11851
122D
1 1355
=j
'JUS28-2
LUS28-2
18
3-1/8
7-1/8
2
1
-
6
16d
4
16tl
11325
151011645{
130
SUH26r2
I U26-2
16
3-1/8
5-1/16
2
1-1/8
_
10
tOd
4
10d
11250
14051
15151
755 '.
10
16d
4
10d
1470
1670
11BOD
j 755
SUH28-2
-
16
3-1/8
6-1/4
2
1-1/8
_
12
1 10d
4
10d
1500
'1695118151
755
12
16d
4
10d
1765
'1915119151
755
HUS26-2
M26-2
14
3-1/8
5-1/4
2
1
4
16d
4
16d
10M
( 12MI13WJ
1155
HUS26-21F
HLW26-2
14
3-18
5-1/4
2
1
4
16d
4
16tl
1085
1235-
-I 3o-0
ri155
(2) 2 x 8
HUS28-2
HUS28-2
14
3-18
7-118
( 2
1
-
6
16d
6
16d
'1625
.18501
19951
1810 1
HUS28-21F
HUSC28.2
14
3-18
7-18
2
1
-
6
16d
6
16d
:1625
1850
19951
1810 11
S.
HD26-2
W26-2
14
3-18
5-1/4
2-12
1-18
Son
Max
8
12
16d
4
10d
12i0
13901
1490.1
780
if
�
6
1850'
21.
2235..
-
1170
HD26-21F
HU026-2
14
3-18
5-1/4
2-12
-
min
8
16d
4
10d
1230
14RO1
-780
Max
12
6
IBM,
i243U
2235
1170
HD28-2
HU28-2
14
3-18
7-18
2-12
1-1/8
Mon
Max
10
14
16d
4
Intl
1540
{
1865
780
6
2155
12110...1170
HD28-21F
HUC28-2
14
3-18
7-1/8
2-12
-
Mbf
10
16d
4
Intl
'7540
1735
IS
780
Max
14
6
Z155
2430
26101.
1170
- i
'
JUS28-2 I
LUS28-2; 1-
1S ,
2l.-78
'::.7-18
:.ZC
1',
...._
.6-
:16d=
-.4
16d:..1825
1510.
1605.j
1355
JUS210-2
. L=10-2 ::
` 18
•3-18
.=9r18 -.I
. 2 1
' 1 -
B 4
.16d
'-:fi j
16tl i1
9845'
21 W
.2290:
1980
SUH28-2
_ ..
:1fi
318'
F114
2,.I1
1/8
1_
--]2
1@tl,
"- 4'1i
IM 1
15M
7685.
7815
755
1
12
16d-
.47
106 1
1765.1
191511915
755
- .:
:..
SUH210-2 "`.
.,'
UZ10-2 .:
:16
.:-'.
3-18
•°.
8-01
, 2
1.78
•.
---
16-
10d`
'-fi,
Intl 1200-
2245124201
1135
16.
4fid-`6
:-110d'0
235
26702880
1735
HUS28-2 . •..
.HUM-2
14-'
3-118
71/8
'2
"-1 :
- --'.
•6 '
.. 16d.
6
.16d :11625.
1850,19951
1810
HUS28-21F. -:
HMG283!"
=".14
3-1/8
'7-118
' 2'.:.1r-
.6
16d
_ 6'
15d
1625�
1850
1995
1BID
'
_(Z12k10
HD38 2
HU28-2
<i4
31/8...
7118
z 112
..
7-1A
.:rMar
ALn
1O.
.14--
-
1fid:
".
.'4.
_..-
1`lld -
1540
2155
1735:
2A30.
7865
2610
. 7B0 .
. 1170'
:
6."
-Ni'o
-
HD2821'r .,-•.F7UC2B2
;14
3]8
.'718
_
212
'' •.
.. 10
;16d' -
. 4"
'
tod:
-.
1540
1735'
7865.
' 780
Max'
14
fi_.
2155'
243'
2610
7170 -
-
_,-:
H=G-2 .- ':
'JDS210-2,-�
d4
3-1/8
%.9-18
-:-2-
-.1
8
163-.
`8 -
161:
Z170
.2465
2660
2210-
-
HUS21 D-2ff :.
i0SC21D-2
. 14 .
-3-1/8
:31/
.`2•-_
-`7-.
; -:
'8
160 -"
8"
=16d:
2170:
2465
2660•
2210"
AD210.2 1
,. : I
•
HU210-2,74
318
'-9 s
212
"
f-1/B
Von
Max
14
16d
:6='
-Intl
2155
:2430
4E70'
1170
3080':'3425
3251�:1%D
HU270-?JF
}iUC21p-2
_14 131/8
'� 9
272
_
-,,
.NCui
Max -
14=
�
ifid
fi-
Intl
2155
2430
2610
'1770
3475
378
1950
- ` -:-
HD(1210-� Z
;:HUCO210-2'-
1 14
3-1/4 1
. @
'3. -
7.12
-
':12. 1
1565
6: :
MM
5015;
;559g
5590:
:2975 .
31, R7, F32
11 Upum inaa5 have peen mcreased 60%tor v4nd er seismic loadg no further Increase shag be permitted.
2)1 Sd sinkers (0.148 de. x 3-1/4' bngl may be used at 0.84 of the table bad where ISd commons are spetlfirJt.7hi5 doss not apply JUS, H95, MUS shard fwt hangers
3) For JUS and HUS hanger. Nags must he driven at 30'tn 45 angle though the joist or1n� lob tie header to achieve the table loads. A
4) WS3 Wood Screws are 114' x 3' long and are Included with HDO hangers.
5) NANS 1Dd nails are BUS" dis x 3' long, 16d are 0.162' dla. x 3-12' long.
New products or updated product information am designated in blue fog !; +
Corrosion Finish ■Stainless Steel EGOld Coat LHDG Nhiple Zinc
114 Gantimoed on next page
I
Hangers
Face Mount Hanger Charts
MiTeke
-
�:.
Joist Size
USP
Stock No,
. Bet. No.
Steel
Gauge
FastenerSchedule'Y
'. .'DRW-
AlIMUIp toads Wps-)
r.:
S
Code
.Bah
Header,.
.
Jois[.
.' _
IN
H
-.:
D
:'A
A1id/
Man
: ,
Nan '
:.
' <
Nail -:
Aoor
1DD%115%'125%
. Baof
Upllry�.
160%
SUH314
U314
16
I
2-9116f
10-9/16
2
1-IM
_
18
10d
6 110dx1-112
225012525
Z7251
1135
18
16d
6
lad x1-112
2645120DO
30101
1135.I
M14
HU314 I
14
2-9/16
11-5/16
2-12
1-1/8
Mm
16
16d
8
10dx1-112
2465'
Z780
29801
1280
Max
2d
72
369514170
44351
2045
3 x 16
1013141F
HUG314
14
2-9116
11-5r16
2-12
_
Min
16
16d
8
10d x 1-111
369514170�14435
3051
4170 1
44351
1280
� 2D45
Max
24
12
H0316 I
HU316
14
2-9/16
13-516
2-12
1-118
Min
18
Intl
1
8
10d x1-112
2770
40115144M
3125 j
14435'I
3355
156D "
2045
Max 126
12
HM161F
HUG316 I
14
2-9/16
13-5/16
2-12
-
Minl
Maxi
78
26
166
8 1lad
x 1412
2770
9
3I25
44351
3355i
4485
1560
2n45
12
%(2)3i8...H0382
..
".
..
HU38-2 1
!!!
14
5-1/8,�
6-1/8 �212
!!l
-
j
11/8
. 'Max
j hin I
10 .:
� - .1
16d •..
_
4 I
1Dd_:'
- -
1540
1735
( 1865a
7B0
1
( 14 :
6
2155
( 2430
2610
1170
H038-2
f
I HU3B-2
14
5-1/8
6-12
2-12
1-1/8
Min
10
16d
4
1�
1548
1735
11885'I
780
Max
14
6
2155
2430
26f0;'1170'I
(Z)3x10
iW&2
IHU310-2
(
.14
5-1/8
8
I
2-1/2
1-1/8
Min
14
16d
8
1 10
lad
215512430{28f0"
1170*1
Max
1 20
30M0
3475
37251.
1625
(2)3xp2110312-2
999
g
FIU312-2. {,1
1
14
6-1/8.-�
ID :�.2-1211/e
!!
'1 Mid :{.
Mai:
16
24
1 16d:,
:.q
B
12
.]Od '"
1 '- <"
12465
1 Z780
2980.1
1065
136�
4170
4470"
'?34D
(2)3x14
HD312-2
I HU312-2
14
111
5-1/8
10
2-12
1-1/8
Min
Max
I6
I Tb
16d
8
tad
2465'1
ZMC
z9B01
'1065
1
12
3695
; 41704478
j 2370
- --
JUS26-3z.-.. .I
LUS26+3. ._i.
1H
I4-5/81-412
1 2'"I
1
1 --"i.
4 -1
16d 4
�4 .;
l6d e..
104017185�
1228j
13551
.
SUH2G-3
j :112"o-3 -
16 -
45/8
-5-1/4'-
2
' 1. 1
- •(=
=•
'
I 8"
:. tad. 1.
2
10d
10001112D
1165
% 380`
1. 8
1 Ind
.2
10d
i 176511165
11651
380 -
(3f2x6
11D 3-
�HU26-3
-
-14
'4-5/S-
:.
4.12
2-12
-
1-1/e
.Nan
I' B
16d
..,
{ '4
6
6
1 =
1Dd
1 =-.11850
12�11390
1490.(
7e0
5
Mal
12
2085
22351'
1170
"
3i02G-31F'
� 'HIIC28-3'"
!!1
14
4-5/8
4-112
111
2A2
Mid,.
Max 1-
- 8
12
-
16d -
4
1 10tl
. =,1
12M
11390
114901
780
85,
F2
"- s
18.50.
208.5
z2351
117a
JU526-3
I WS26-3
18
4-518
4-12
2
1
4
16d
4
Intl
11040
11185
11220
1. 1355,1
JUSZB-3
I UWS-3
18
4-5M
6-3/B
2
1
6
tad
4
16d
1 1325
1510
1645
1355
SUH26-3
U26-3
16
4-5/8
I 5-1/4
2
1
_
8
10d
2
lad
1000
11201
1165.
380'
8
16d
2
lad
11651
1165
1165'I
380
HD26-3
HU26-3
14
4-SM
I 4-12
2-12
1-118
Min
a
16d
4
lad
1230
13901
1490
780
Max
12
6
1850
2085
2235.
1170
(3) 2 x 8
HD26-311'
I HUG26-3
4-12
2-12
_
Min
B
16d
4
1�
17M
139011490:
780
1
Max
12
61:1170
HD28-3
-
L144.58
4-5/8
6-3/8
2-12
1-1/8
Min10t16d
1ad1540
1735
11865.
-780-
Max
142155
2430
2610
1170
H028-31F
-
4-5/8
t 6d18
2-12
_
Min
10
10d
1540
7735
1865780
Max
14T610
1170
'4=578
i- 6-3IB'
c 2+
..1
"..
b :
•- 76d %.
1325'I510
1645
1355-1
B
1
'.- .16d . '
1845'
2105
2290
19B0',_
.
SI1H2103 ; :
❑210-3
16
4-5/8„
10jil
_
„ 2
-:
1
-
14
7
` `10d --
1750
1965
2128
1135'.
14
:: 16d1. �.
6
`- lad .'-
2D60i
2335
Mill
.1135
14
'4-5/8
6-3/8
2-12
-
1=1IB
Min' .
' IO
-. 16d
.:4
.-.
18d-: `.
150
2155-
Ins'
2438
180..
2610
780: `
1170
Maz
16
.-8
RX10_:
,HD28-30_ .'
--..
14
4uT/8I
-
6-3IB
212
'.
-
Intl
4
-.6
1Dd =i
i548.
7735
7865...788
-Max`
14
2155
2430
-2610
1170`
HU2103
1
14
-
45/B
B-1/4
272
1 7IB-Max10d
r'.
20
-.'
2155.:2430
2610
1170:
10
3080
3475.
37251
1958.
i
H021D•31F'-"
HUC270-3' :
14
4-5/8-
6-174
i-IA2
-
. •
ATm.....14
6
"10tl ;
2155
3080.
2430
3475:
261D1170.
TM
19%
Max-
20
10
100210-3@--j-HUCGZID-3.�
"-14._14-SM
9
".3...
71/2
.-. %-.12,-:WSi
1.F32
1) UpIdt bads have been increased GA torwintl or satanic loads; no tudher hlaease shall ba perMDed.
2)166 sinkers (0.148 dia. x 3-114' long) maybe used at 0.B4 of the Fable load where 16d commons are specified. This does not applyto JUST MI5, MILS slat nail hangers
3) WS9 Wood Screws ane 1/4' x 3' long and are Included with HOC hangers
4) NAM 1 Od nails are 0.148' Ms. x 3' long, i6d nails are 0.162' dia. x 3-12' long•
New products or updated product hdommation are designated in blue font-
. A
Corrosion Finish EStandess Steel 06old Coat G'1HDG UTdple Zinc F-
FW
Coallnued on next page 117
R ers
Mount Hanger Charts
MiTek6
"
'JaistSrre
USP.... - -
Sfpck No. '
_
`Ref.No,
' Steel
Gauge
D'onfnsions(m)
'-2sfenwschedule`''f'
":..Header..:.-.Allpwahle
DFlSP'
Loads (Ws.)'..
.:
e
=
c4>
Gode
Reh
W��
H'
0
A .
- Mol�'•
Maz
-''Nail.
_
. NaO.
Roer
Roof UPlitt
100Y'
17596
725% 16016
JUS46
WS46 I
1B
3-5/B
5
2
1
-
4 1
16d 1
4
16d 1104011185112201
1355
S10146
U46
16
3-9/I6
b13716
2
1-t18
_
1D
10d
4
10d
1250.1
1405
1515j 755
1800:1 755
10
16d
4
10d 1
1470'1
1670
HUS46
NUS46
14
3-WB 1
5
2
1
4 1
16d I
4
16d 1
10851
1235
13DO 1155.1
4x6
HU5461F 1
HI15C4fi
14
3-5/8
5
2
1
-
4
16d
4
16d
1085 1
1235
1300i 1155.1
HD46
HU46
14
3-9/16
5-1/I6
2-12
1-1/B
Min
8
16d
4
IN1850
173IY
13901
14901 '780''
Max
12
6 1
2085.
22351 1170
HD468=
HUC4fi
14
3-9/16
5-1fi6
2-1/2-
Min
Max
8
1 12
16tl
4
10tl
123D 1
139D 1
1490 ! . 780 .
6
185p1
2WS
22351 1170 "
.. -'
.MS46' "?' _
r 111546: 1
18 13-SA11
..:: 5 : -I
2 .1'
1
_ Al
A I-
t6d
4' 1
16d'f'
11040
1 11851
1220 { 1355'
- .-'
JIIS48
4. 1
•16d'-11325
115101
16451 1355
. f
SIINbfi ;,
U46"
'.. 16
:14:
3-9/16.�"4-13tl6
1: 2
-
1 1/B
- ..,i,
ID
YOd `:.
-4
10H `:..
.1250
1405
1515'1 755 .
1ODD '1 755
111116tl.
1
.4
-cod.- :..
1470
1670
HU
HUS46 -.1
3-5/8I
i 5
2 .;.
1.-..
-b.^I
4"
'"16d
4
16d<- I1035
123511300.1
1155.1
HUS461P �'"- _
HUSC46 1
14 -
3-5/B
'S ..
2 "
..1 �'
- '
4
- 16d.
' _ 4:=
16d"- --
10851
1235
1300.1 ".1155 '
HUS48
H1648" :1
14 .1
3--%
""T ","a-1.
1'.._.I
�-
1 6.1
16d
I 6;)
16d_..I
1625
111156
1199511810.:
HLISMIF
1 HUSC48' 1
14
:3-5M1
7
F- 2 I'
1
-
6
16d
6
1 t6d-
162511850
j 1995 1610
:".
FID46 :, ';
HI746 ..
14
3.9/1$
5-?/1fi
I.2-12�
1-1/8
1fid
10d'
1230.1
1390
1 14901 '780
6
1850'12085
2235 1170
"
HD46F .. _
1 HUG6..=.
14
3-9h61
..
5-1t;
2-12
-....
: Mn.
Max
8
112 •
16d
4
6_1-
tOd-"
12301
1390
14901 780 ..
5,
R5,
1850"I
2085
{ 2235. 1170
HD48 .;
111
HU48
14-
3-9nd
B-15116,i
'i
2-12
1
7-1iE
-ISn
10
166
.4
.: ..
10d .'
_
1540
1735118651.
780
F2
M2x
14
1'- 6
2155
2430126101.
1170.
'
HD48F -,•
:.,
HUC4B; ..II
.. ;'.1
14
3-9116
. •.
615t16
"
2-Y21_
I -
1- -
IWn
10
-16d
4
10tl --.1154013735
:-:
2155
2430
1865 780'
26f0:{..1170.
.Max-
:14-,
6
JUS4B
LU548
18
3-5/8
1 6-7/8
2
1
6
16d
4
16d
1325
.1510.
1645 1355
JUS410
L16410
I 18
3-5111
8-71B
2
1
8
16d
6"
16d
{ 18451
2105
2290- 1980
SM410
I U410
16
3-9116
B-3/8
2
1-18
_
116 6
10d
6
1 10d
2000
2245
24 119
16d
6
10d
1 23M
267D
F20r
2aB01135.
HUS48
HUS48
1 14
3.5/8
7
2
1
6
16d
fi
1 16d
16251
1850
19951 1BID '
HJS491F
HUSC48
14
3-5/8
7
1 2
1
6
16d
6
1 16d
16M
I 18M
1995 1810
HD48
HU48
14
3-9/16
6-15/16
2-12
1-1/8
Min
10
16d
4
10d
1540
7735
18B5. 7"
Max
14
6
21551
2430
200' 1170
4x16
HD48F
HUC48
14
3-SM6
6-15/16
2-12
_
Min
10
16d
4
10d
/54011735
]8651 780
Maz
14
6
215512430
26101 1170
HUS410
HUS410
14
3-518
B-7/8
2
1
8
16O
8
1 16d
2170
2465
2660:1 221D '
HUS4101F
HUSC410
14
3-5/8
B-7/8
2
1
8
16d
8
16d
21701
2465.
2�0 " 2210
.
HD410
HU410
14
3-9116
BINH
2-12
1-18
Min
14
16d
6
10tl
2155
2438
26f0'{ 1170
.
Max
20
10
3080
{"3475
3775 { 1950
RD4101F
HUC410
14
3-9116
B-13/16
2.12
-
Min
14
tfid
6
1�
2155
2430
26f0 '1170
Max
20
10
3DW
.3475
'3725" 1RM "
HDO41 OIF
I HUM910
14
3-9116
9
3
1.12
12
W53
6
W53
5015"
5590
5590 29751
31,E F32
1) Opg t (pads have been Increased 60%for vdnd or seismic loads, no funha Increase shag be PermiOed.
2) led sinkers (0.148 dia. x 3-1/4' long) maybe used at 0.84 of the table load where 16d commons are specified. This does not apply WAS, HUS, MUS slam nail hangers
3) WM Wood Sam are 1/4' x 3- long and are inciaded wb HD0 hangers
4) NAILS I Od nails are 0.148' din. x 3° long, 16d nalls are 0.162' dia. x 3-12' long.
New pmducts ar updated product information are designated In blue fmL
Comusion Finish ■Stainless Steel DGold Coat HHDG ETdple Zinc
RII
119
f
*aI [EB�
MINIMUM GRADE OF LUMBER '
Tap Cheryl 20 SYP a1 SPF S1/f2 or b;tt.r
Duo Chord 20(9 OR 2x4 SP #2H OR SPF p1/#2 or bellar
WEbp 2x4 SYP #0 or bolter
(•)•WA NAY b[ NPPSO FROM A Eve. U'ITOHED OR SQUANIQ
(••) AETAOH EACH VALLEY TO EVERY SUPPORRHO'MUSS. WNHI
(2) 1GG BOX (0,106- A 4,01 NAILS 20E-ELULED FOR
rag ¢21�- ASCE 7.10 „1PH WIND.
MEAN HOOK ENCLOSED BUILDING,
ExP, G. RESIDEHCW.. WIND TO DL-G PSr.
OUT FROM I.N00 AS nEQUIPED
4'-0" Max
SUPPOFMNO
A4
B'-0" Max
W-0"Max Sp
20'-0" Max (**)'
SES AT 24" 0.0, MAXIMUN
SOUTHERN
TRUSS I=o,
OOMPAMIES (BG
`r rL z !F=—p <S� ED Ea•t*-a i I
UNLESSSPECIFIEDON ENGINEEfl'S SFAED DESIDN.. APPLY 1x4 T—BftAC1r e0x
UNLESS OF NC¢ YALI£r MS 'OF.'0. M.
QRA OR BEr1ER AT
WITH ad Box l0'.i70 2.B Id
nT Oc, OR OONRNOCUB UT�ML BfN01Ho,
EQUALLY SPA. FOR CAL VALLEY WEBS ONEATER THAN T'-0 .
MNOMUM VALLEY VERRCAL HEIGHT MAY NOT E%OEED 12'-0",
TOP OHURU OF TRUSS .EO BEKATH VALLEY SET MUST BE BRACED WRHI
PROP IXOATTACH[D, PATBHGTMNO APPLIED PRIOR TO VAUXY TRUSS
ON J/11 fl
GfiRUNS AT 24" or -OR AS OTHERWISE SPECIFIED ON ENGINEERS' SFAEO DESIGN
BY VALLLRS' 6PALE0 USED im UEU OF PURUrN� SPACING AS SPECIFIED
THON
(,r•)9 UTH TIETMVAIley q NGWVP� AIANo TH SLOPE OF T14E TOPPCHag. TRUSS
(••) LARDER SPANS FAY•BE BUILT AS LONG AS TILE VERTICAL HEIGHT DOES
HOT DWEE0 12-0.
BOTTOM CHORD MAY BE SQUARE OR PITCHED CUT AS SHOWN.
eQVARE Cur ••)10E2RUMM
vALtET. � �
SPACING.
FneDan br
roir Wn 1
oddo. R91
an4 e
WMID
t Plerce Dlvlelat
2eao ryry IOPB, M hno .
Fort PI1o6 FL 4BB1
Ioff
4232—CBOB ((772 464—h1e0
TMUN M
Far. 771)71B—OO1S
Thu. no T
1pre014 o0
0
•
ceaxo RE.�.,
OPTIONAL: STAB
END VERTICAL
'V cl rr E—I T
not ih. n.pa NiV of Ina
pwmi tw .recllnp Weep am
eon
OPTIONAL HIP
JOINT DETAIL
FRAMING
TO LL
20
20
PSF
TO OL
10'
16
PSF
6C DL
10
10
PSF
BC LL
00
00
PSF
TOTAL LOAD
40
46
PSF
01113010L701
1.25
1.26
�j
SPF
p
HF
sp
N
DFL
j
o
Sp
a�
o
HF
SP
0
DFL
E
C7
E
o
HPF
v
N
SP
:
r
DFL
0
or vPrtnaN•
C��ble end rua E; EDE�
SOUTHERN
TRUSS
COMPANIES
M.
REFER TO CHARS ABOVE FOR MAX
FnuOon 6rvi(np 4
nm Ume la6tloola
adrks nymdlnp 1
mid domkwlnp ui
Fort Plerce D!V18106 ,poomo-appAau9oR
1I
s
• 0.^eLE'Itiube DETNL NDifai
OVE LOAD DEFLEDIIDN CHNFAN I8 VZ40.
"U'laE'UPLJFT Coll To"uNB FOR 139 V
DOtGINu, 1149. is P8F 10 DEAD IDM
oAeiE ENo BU�TRPNOPiOiRIs_ S°rD PROM a.{
9L��DO�oYFAWWv v DyFAHANO.D%D1p'
"I FACN I- GRADE WRN tod
11 i7 FOR [7pp77 L' BMC 9PAOE
e�)FOR [3)ZBMCL91 SPADE AT 3
l8' FJi , ZDN6 AND a' 00. 11MW ZONED.
G16 I�FF.vieMiuN� BE A MINMUM OF DOR of T'
VEFm P 16 el
O BP O
e k—o 1R4 O 7x]
1E99 W7 11'-iB D•� BUF 2n4
v u ER _e s.en
c Rse o R
PFlni SPWE AHo HEEL PIATEe,
//////i/e�e
WLE VERi1CAL LEHM
n/ Ct rat T 1-1 9
ml um InpcTim FI imn iTim"pal
e
Maximun Total Load 80 PSF
SPACING AT 24" O.C.
-Fypic;al PLgg�y C:-' k ED IE�- t Eii
MINIMUM GRADE OF LUMBER
-Top Chord 2x4 SW F2 or better
Boll Chord 2x4 SYP $2 or better
Web, 2x4 SYP #3 or bettor
RUM TO SEALED DEMON FOR DASHED PLATES
SPACAExPIQOYBACH VERnCAL9 AT 4' CC MAX
R NOT) VVITOLY WCHORDER SPLICE MUST BE 9fAGUERED 50 THAT ONE SPUCE
ATTACH PURUNS To TOP OF FIAT TOP CHORD. IF PIGOYBACx
W 9olRl LUMBFA 0 BOTTOM CHORD 19 DMRTED PURUNS
M4Y BE APPl1ED B 7H 70P CHORD of SUPPdRRNo TRUSS.
REM TO ENOINEEA'S SEALED DESIGN FOR REQUIRED PURUN SPACING.
THIS DETAIL 19 APPLIGBLE FOR THE FULLUMNO WIND COROMONS:
1_fa0 MPH WIND, 30' MFAN HOT. ASCE 7.10 CLOSED BLDG.
LOCATED ANYNHERE IN ROOF. 1 MI. FROM CUASr
CAT I EAP 0. WIND TO 01> 5 PSF, WIND BC D4" PSF
14U WH WIND. 30' MEAN W. FOC�,O 10
BATD9ED BLDD. LOCATED ANYWHENE IN HOOF
WINO To OL-a PSF, WINO BC UL"a PST.
WEB BRACING CHART
WEB LENGTH
REQUIRED BRACING
0' TO 7'9"
NO BRACING
1x4 i" BRACE. SAME GRADE; SPECIES AS WEB
7T TO 10'
MEMBER, OR BETTER AND BOX LENGTH OF WEB
MEMBER. ATTACH WITH Bd NAILS AT 4" 0/C.
20 "To BRACE. SAME GRADE, SPECIES AS WEB
10' TO 14'
MEMBER, OR BETTER AND BOY. LENGTH OF WEB
MEMBER, ATTACH WITH 16d NAILS AT 4" O/C.
JOINT
SPANS UP TO
TYPE
30,
34'
36'
52'
A
20
2.5x4
2.50
3x5
B
4x6
5x6
5x6
5x6
C
1.5x3
1.5x4
1.5x4
1.5x4.
D
5x4
I 5x5
5x5
5x6
�C
I"I
I -c
I
laic
I
i�Dr -- IDIc
*ATTACH PIGGYBACK WITH 0"xl3xl/2" COX PLYWOOD WITH 4—#5d NAILS IN EACH BOTH FACES 0'4'-0" O.C. MAX.
W/ a e— e-1 T r--e S:—;
Decllon bracing Is rml the responvbblly of Lrur designer, plate mamdoala:er
nor !rase labdcolar, penlmv ereclIng baeses one malloned to seek pmloselarld
ishi a eegondIng Coogan bmdlq wMeh Is alwode mgalmd to prerenl toppling
Pierce Division °� domb airy daring snatlmg end velmanent bracing which may be requhd In
P0 N. xiepe HIyivi , eoedl'n apppnaliom. S" Iscst—BI $1 MM shoot Cammenkay and Ma mon—
rrt Ple:ee, FL J4W r LaOanr fw hmdfmg, 5idabby 3 Emv6q meld plate ewelechd road twarer ilPl).
32-0505 (77I)04-4150 Twelve m to be erecled and Intend M radelnd In o sMlghl oM pp mb pon1lon
Fox:(772)318-0010 who no shsatry�q Is oppl'Nd dbmllp to the lap di ph, Nay shall be braced w
spseilbd on the 1.1 duigm TNvee shag be hard s wM nammMe care during
Colon to Fred damwe.
C.
C
Maxlmun Loading
55paf at 1.33 Duratfan Factor
50psf at 1.25 Duration Factor
47psf at 1.15 Duration Factor
SPACING AT 24" O.C.
SCAB -BRACE -DETAIL I ST - SCAB -BRACE
Note: Scab -Bracing to be used when continuous
lateral bradng at midpo nt (or T-Brace) is
impractical.
Scab must cover full length of web +/-
THIS DETAIL IS NOT.APLICABLE WHEN BRACING IS
REQUIREQAT'113•POINTS OR PBRACE IS'SPECIFIED.-
APPLY 2x SCAB TO ONE FACE OF WEB WITH
2 ROWS OF 10d (3" X 0.131'1 NAILS SPACED 6"'O.C.
SCAB MUST BE THE SAME GRADE, SIZE AND
SPECIES (OR BETTER) AS THE WEB. ' '
�\ MAXIMUM WEB FORCE 25001bs
LE
MAXIMUM WEB LENGTH =12'-0"
SCAB BRACE 2x4 MINIMUM WEB —
SIZE -MINIMUM WEB GRADE OF#3
Nails � Section Detail
®Scat}Bmm
Web
Scab -Brace must be same species grade (or better) as web member.
L-BRACE DETAIL
Nailing Pattern .
L-Brace size
Nail Size .
Nall Spacing
1x4or6
10d
8•=o.c.
2x4, 6, or 8
16d
800.0.
Note: Nall along entire length of L-Brace.
(On Two -Ply s Nail to Both Plies):
LN®
Section DetaO
L-Brace
SPACING
L-Brace must be same species grade (or better) as web member.
Note: L-Bracing to be used when continuous
lateral bracing Is impractical. L-brace
must cover B090 of web length.' '
L-Brace Size
for One -Ply Truss
Specified Continuous
Rows of Lateral Bracing
Web Size
1
2
2x3 or2x4
114
2x6
1 1x6
"*
2x8
—DIRECT SUBSTITUTION NOT APUCABLE.
L-Brace Size
for Two -Ply Truss
Specified Continuous
Rows of Lateral Bracing
Web Size
1
2
2x3 or2x4
2x4
«.
2x6
2x6
*�
2x8
2x8
—DIRECT SUBSTITUTION NOT APLICABLE.
T-BRACE / I -BRACE DETAIL
I
Note: T-Bracing / I -Bracing to be used when continuous lateral bracing
is impractical. T-Brace / I -Brace must cover 90% of web length.
Note: This detail NOT to be used to cram ert T-Brace / 1-Brace
webs to continuous lateral braced webs.
Nailing Pattern
T-Brace size Nail Size .
Nail Spacing
1x4or1x6 10d
8'o.c.
2x4 or 2x6 or 2x8 16d
8' O.C.
Note: Nail along entire lengthnf•T-Brace / I -Brace
(On Two-Ply's Nail to Both Plies) . .
alternate position
144M-7
Section Detail
T-Brace
�.'=M�- web
alternate position
Nails
web
Nails
kBrace
Brace Size
for One -Ply Truss
Specified Continuous
Rows of Lateral Bracing
Web Size 1 2
2x3 or 2x4 I 1 x4 (q T-Brace .1x4 (') I -Br.
W 1x6 (7 T-Brace 2x6 I -Brace
2z8 12x8 T-Brace 2x8 I -Brace
Nails
Brace Size
for Two -Ply Truss
Specified Continuous
Rows of Lateral Bracing
\� SPACING Web Size 1 2
241 or 2x4 2x4 T-Brace 2x41-Brace
2x6 2x6 T-Brace 2x6 I -Brace
2x8 2x8 T-Brace
T-Brace / I -Brace must be same species and grade (or better) as web member.
(q NOTE If SP webs are used in the truss, 1 x4 or tx6 SP braces must be stress
rated boards with design values that are equal to (or better) the truss web
design values.
For SP truss lumber grades up to #2 with 1X bracing material, use IND 45 for T-Bracell-Brace
For SP truss lumber grades up to #1 with 1X_ bracing material, use IND 55 for T-Brace/l Brace
1462-A
- 3116 in
r -a = I 15 14 13 12 11 10 — 3x5 =
R
3z0 M786H511 3x4 = 4x6 = 3x4 = 3x4 = 4x8 = 3x4 = 3z10 M189H51
LOADING(psf)
TCLL 20.0
TCDL 7.0
BOLL 0.0
BCDL 10.0
SPACING- 2.0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Ina YES
Code FBC2017/TPI2014
CSI.
TC 0.96
BC 0.76
WB 0.59
Matrix-S
DEFL In (loc) Well Ud
Vert(U 0.22 12-13 >999 240
Vert(CT) -0.42 12-13 >999 180
Horz(CT) 0.13 9 We n/a
PLATES
MT20
M18SHS
Weight 213lb
GRIP
2441190
2441190
FT =10°/
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied.
T1: 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 7-5-6 oc bracing.
BOT CHORD 2x4 SP M 31
WEBS 2x4 SP No.3
WEDGE
Left 2x6 SP No.2, Right 2x6 SP No.2
REACTIONS. (size) 1=0-8-0 (min. 0-1-8), 9-043-0 (min. 0-1-8)
Max Hoal=159(LC 8)
Max Upllft1=529(LC 8), 9=529(LC 9)
Max Gmvl=1529(LC 1), 9=1529(LC 1)
FORCES. (Ib) - Malt CcmpJMax Ten. - Al forces 250 (lb) or less except when shown.
TOP CHORD 1-2=325811114, 2-3=3083I1077, 3-0=-2966/1095, 4-5=2377/865, 5-6=-2377/865,
6-7=2966/1095, 7-8=3083/1077, 8-9=3258/1114
BOT CHORD 1-15=1097/2934, 14.15=-814/2449, 13-14=814/2449, 12-13=450/1809,
11-12=-654/2449, 10-11=-65412449, 9-10=9382934
WEBS 5-12=3291774, 6-12=650/441, 6-10=215/564, 8-10=297297, 5-13=3291774,
4-13=-650/441, 4-15=215/564, 2-15=297297
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (&second gust) Vesd=124mph; TCDL=4.2psf; BCDL=5.0pst h=151t; Cal 11; Exp C; End., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcumant with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qrib)1=529.
9=529.
LOAD CASE(S) Standard
GENg��T� i
P 5 �_
! 1
r
1t STA OF 7
3x6= 3X6_
5.00 12 Sx5 =
Dead Load Deg. -114 in
I$
300 MISSHS 11 3x4 = 4x6 = 3x4 = 3x4 = 4x6 = 3x4 =
3x10 M18SHS 11
1-041 &2-6 1 17-0-13 1 24-11.3 I 32-9-10 1 41-0-0 42.OA
1-f�F 8.2-6 7-10.8 7-11 7.10-6 6-2-6 -0-
Plate Offsets (Y Y1— f1:0-04
Ednel 11:0-0-14 Edoel
t5:0.3.12 0.2.81
f6:0-2-8 0-3-01
P:0312 0-2A1
111:0.6-14,Edae), 111:0-0-4,Edael
LOADING(psf)
SPACING- 2-D-0
CSI.
DEFL.
In Poe)
Well
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TO
0.84
Vert(LL)
026 14-15
>999
240
MT20
2441190
TCDL 7.0
Lumber DOL 1.25
BC
0.76
Vert(CT)
-0.5114.16
>968
180
M18SHS
2441190
BCLL 0.0
Rep Stress Ina YES
WB
0.52
HDrz(CT)
0.13 11
We
n/a
BCDL 10.0
Cade FBC2017/TP12014
Matrix-s
Weight 211 Ib
FT= 10%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 •Except•
TOP CHORD Shuctural wood sheathing directly applied or 3-0-12 oc purilns.
T2: 2x4 SP No.2
BOT CHORD Rigid ceiling directly applied or 7-6-12 oc bmdng.
BOT CHORD 2x4 SP M 31
WEBS - 2x4 SP No.3
WEDGE
Lett 2x6 SP No.2, Right 2x6 SP No.2
REACTIONS. (size) 1=0-8-0 (min. 0-1.8), 11=0-&D (min. 0-1-8)
Max Hom1=148(LC 8)
Max Uplift1=517(LC 8), 11=517(LC 9)
Men: Grav1=1529(LC 1), 11=1529(LC 1)
FORCES. Qb) - Max. Comp./Max. Ten. - All forces 259 (Ib) or less except when shown.
TOP CHORD 1.2=326711089, 2-3=-3088/1051. 3-4=3012/1069, 4-5=2368/826, 7-8=236B/827,
8-9=-3012/1069, 9-10=.308Bf1051, 10.11=3267/1090,5.6-2133/810, 6.7=2133/810
BOT CHORD 1-17=1065Y2945, 16-17=-764/2428, 15-16-764/2428, 14-15=427/1826,
13.14=-615/2428,12-13=-615/2428,11-12=917/2945
WEBS 6-14-296f729, 8-14=5901402, 8-12=232/585,10-12=-318/313, 6-15-2951729,
4-15�5901401, 4-17=-231/585, 2-117=-318/312
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuit=160mph (3-second gust) Vesd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. It; Exp C; Encl., GCPI=6.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates we MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads.
6) Pmvide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except (p=1b)1=517,
11=517.
LOAD CASE(S) Standard
-Job
Inuss
inass Type
Ory Ply
Oakland La" -Lot 60
1452-A
A3
HIP
2 1
Jab Reference o donal
aoulttem Truxs, Fl Pearce, YL, 34aS1 ,mn: o.c.u. —a, a,. ..—.. w..,
ID:EaPDUhgCVVA016wSO7VTFdz75cK-nVTKkQi4eYIVwIOFEDJSPtXyRygl7vA0iCgxErny JA60
633 N35 1]-fi-0 24-SD 30-511 3S&t3 42-00
63J 52-1 641t ]-0-0 6-0.11 52-1 1 '3-3
5x7 =
6.00 Fff
5x5 =
Dead Load Deb. = 3116 in
I¢
3x5 = 3x4 = Us = 3x4 = 3x8 = 46 = , 3x4 = 3x5 =
as 42aa
1-60 943 17$0 24-e-0 32-7-13 4a 4k ,
4-011 M F &1-13 I M &1-13 I &0.4DWO
bL0 1-0-0
Plate Offsets (X,Y)- fl:0.3-10,0-2-81,
f6:0-5-4,0-2-81,
f12:D310,0-2-81
LOADING(psf)
SPACING- 24-0
CSI.
DEFL
In Qoc)
Vdefl
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip.DOL 1.25
TC 0.93
Vert(LL)
-0.20 16
>999
240
MT20
244/19D
TCDL 7.0
Lumber DOL 1.25
BC 0.42
Vert(CT)
-0A71&18
>999
180
BCLL 0.0
Rep Stress Ina YES
WB 0.77
HDrz(CT)
0.13 12
n1a
n1a
BCDL 10.0
Code FBC2017fTP12014
Matrix-S
Weight 2271b
FT= 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP M 31 ,
WEBS 2x4 SP No.3
SLIDER Left 2x6 SP No.2 2-11-8. Right 2x6 SP No.22-11-8
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOTCHORD Rigid ceiling directly applied or 741-0 oc bracing.
WEBS 1 Row at midpt 6-15
REACTIONS. (size) 1=0-8-0 (min. 0-1-8), 12-0-8-0 (min. 0-1.8)
Max Horz1=133(LC 8)
Max Uplifts=500(1_C 8), 12=500(LC 9)
Max Gmvl=1529(LC 1). 12=1529(LC 1)
FORCES. (Ib) - Max CompJMax. Tan. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=325611053, 2-3=3178/1065, 3-4=-30361951, 4-5=2937/960, 5-6=23551M.
6-7=21241755, 7-8=2356?77, 139=2937/960, 9-10=3036/951, 1D-11=317811066,
11-12=3256/1053
BOT CHORD 1-18=1033/2933, 17-18=-805/2618, 16-17=805/2618, 15.16=504/2124,
14-15=672J2618, 13-14=-672/2618, 12-13=90012933
WEBS 3-18=237/256, 5.18=711428, 5-16=6431385, 6.16=165/556, 7-15=1171557,
8-15=6431395, B-13=-721427, 10-13=237M6
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.epsf; h=1fit Cat II; Exp C; Encl., GCp1=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurtent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of wiMstanding 100 lb uplift at)oint(s) except (It=Ib)1=500.
12=500.
LOAD CASE(S) Standard
oW
p OS `7
r
ti JL
STATE OF ZZ
RIDP
ONA� �ENGa\\\ 129
Job
InIn
I was I ype Piy Oaaand Lake -Lot 60
1452-A
A4
jQry I
HIP 2 1
Job Reference (optional)
i
6.00 12
5x5 =
3x4 = 5x5 =
Dead Load Deft. -114 in
3z5 = 1.5x4 II 3X = 3x4 = 3x8 = UG = 1.5z4 II V^ 3x5 =
3x4 =
1.n-n 0.Md
7-0-14 7-1-2
5-5-7
6-2-9
7-1-2-
7-0-14
Plate Offsets
(X Y)- f1.D310
0-3-01. 17.0-2-8 0-2-71 r11.0310 D.3-01
LOADING(psf)
SPACING. 240-0
CSI.
DEFL.
In Qoc)
Udall
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TO 0.79
Vert(LL)
0.24 15
>999
240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.83
Vert(CT)
-0.44 17-18
>999
180
BCLL 0.0
Rep Stress Inv YES
WB 0.26
Horz(CT)
0.19 11
n/a
nla
BCDL 10.0
Code FBC2017rrP12014
Matra-
Weighb 230lb
FT=10%
LUMBER -
TOP CHORD 2x4 SP No.2'Except'
T2:2x4 SP M 31
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
SLIDER Left 2x6 SP No.2 3-8-4, Right 2x6 SP N0.2 3-84
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 6-1-0 oc bracing.
WEBS 1 Row at midpt 3-17, 6-14, 9-14
REACTIONS. (size) 1=0-8-0 (min. 0-1-13), 11=0-6-0 (min. 0-1-13)
Man: Horz 1=118(LC 9)
Max Upiiftl=-480(1-C 8). 11=-480(LC 9)
Mau Gmvl=1529(LC 1). 11=1529(LC 1)
FORCES. (lb) - Max CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=3275/966, 2-3=3149/983, 3-0=2591/846, 45=2506/869, 5-6=-2437/904,
6-7=2279W% 7-8=2505/867, 8-9=25911844, 940=3149/984, 10-11=32751967
BOT CHORD 1.18-933/2950, 17-18=93W950, 16.17=-61212291, 1516=-61212291,14-15=68712448,
13.14=835/2951, 12-13=83512951, 11-12=835/2951
WEBS 3-18=0/314, 3-17=706/420, 6-17=100/462, 5-15=107/396, 6-14=-435/137,
7-14=1321627, 9-14>707/422, 9-12=01311
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3second gust) Vasd=124mph; TCDL=4.2ps(; BCDL=5.Ops, h=15f; Cat. II; Exp C; End., GCpi=0.16;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconctment with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift etjoint(s) except (jt=lb)1=480,
11=480.
LOAD CASE(S) Standard
I OOD
Truss
Inuss lype
0axland Lake-Lotea
1452-A
A5
HIP
jury jPiy
2 1
Job Reference (optional)
Southem Toss, FL M.. FL, 34551 can' esou vn 2i zwni m u
ID:EePDUIWCVVA016wS07vTFdY15cK-Fhliym)iPstLYB7RnwrKy446)MwMcPgX wvnCy H87
7-0.1d t3.6-0 2i-0-0 268-0 34-tt-2 azOo
M14 GS-2 7-fie 74'+0 N:2 7-0-ta
5x7 =
1.5x4 11 5x7 =
Dead Load Deb. = 114 In
N
I$
US = 1.5x4 II 4x6 = 3xe = 3x4 = 1.50 II US =
3x4 = US =
i 0 42-M
1 1360 214L0 2BS0 3L11.2 46ea 4KW
'I se-1414 I ssz i ras i 7EU 1 eaz 1 sa144 as M
eJ-0 1-0 0
Plate Offsets (X,YF f1:0310,0-3-01,
f4:D-S4,0-2-81.
[8:0-5-0,0-2-8], [9:0310,O-3-0]
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL
in (loc)
Vdefl
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 125
TC 0.96
Vert(LL)
029 13
>999
240
MT20
2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.79
Vert(CT)
-0.5213-15
>957
180
BCLL 0.0
Rep Stress Ina YES
WS 0.56
Hoa(CT)
0.19 9
We
n/a
BCDL 10.0
Code FBC20177rP12014
Matri(-S
Weight: 223 lb
Fro 10%
LUMBER -
TOP CHORE) 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
SLIDER Left 2x6 SP No.2 3-4-13, Right 2x6 SP No.2 34-13
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 6-2-10 oc bracing.
REACTIONS. (size) 1=0-&0 (min. 0-1-13), 9=D-8-0 (min.0-1-13)
Max HOrz1=103(LC 9)
Max UpliR1=-472(LC 5), 9=472(LC 4)
Max Gmvl=1529(LC 1), 9=1529(LC 1)
FORCES. (lb) - Max. CompJMax. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2-3281/1030, 2-3=3164/1045, 3-4=2724/963, 4-5=2855/1104, 5-6=2855/1104,
6-7=2724/963, 7-8=3164/1046, 8-9�3281/1030
BOT CHORD 1-16=89712955, 15-16=8972955, 14-15=-7232461, IX14=7232461, 12.13=-7192461,
11-02=719/2461, 10-11=8942955, 9-10=894/2955
WEBS 3-16=0269, 3-15=563/351, 4-15=79/443, 4-13=226/644, 5-13=457/348,
6-13=226/644, 6-11=-79/443, 7-11=563/352, 7-10=0269
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vul1=160mph (3-second gust) Vesd=124mph; TCDL=4.2psf; BCDL=S.Opsg h=15$ Cat II; Exp C; End., GCpl=0.18;
MWFRS (envelope); Lumber DGL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (V-1b)1=472,
9=472.
LOAD CASE(S) Standard
M.
OC &
STATE OF
�i F OR12P%���
Job
Inas
I runs Type
Fly
Oapantl lake-Lct60
1452-A
A6
HIP
ILIty
2 1
Job Reference o tlonel
6aNhem Tress, FL Pie=, FL, 34951 nwr. a<ou n -- cu m rn,' o...� e.... ', ....,...�. �..............a .�..- .. _........� .-..-.-_ �._ . _
ID:EaPOUIwCWAO16W6O7vTFdY75cK-jta496KKW9 6 KedLeM2UHcN 511-xt h9W92Jey HB-
a614 17-6-e iiVoo 24-2-0 30-6-0 35-11-2 42-0-0
G0.14 &&2 G-4-0 t,d-0 6-0-D 55-2 60.79
5x5 =
30 = 3x6 — 3x4 = 5x5 =
e . a
Dead Load Dell. - 6116 in
3x5 = 1.5x4 II 3x6 = 416 = 3x4 = Us = 3x8 = 1.5x4 I 3,5 =
de 42-
F_41_Q� 12114 I 11de 21-0-0 I 30.60 I 3511-2 F 448-0 6HI0 ,
-0-0dd�� 4&14 662 Bb9 98-D SS-2 4-&11 0+40 '
nen 14W
Plate Offsets (XY)-11:0310.0-3-01
f1:0-1-14,Edge1
fll:0310030]
I11:1-0-3.Edge1
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL
in Qoc)
I/defl
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.59
Vert(LL)
0.31 15
>999
240
MT20 244/190 ..
TCDL 7.0
Lumber DOL 1.25
BC
0.45
Vert(CT)
-0.5613-15
>B79
180
BCLL 0.0
Rep Stress Ina YES
WB
1.00
Hor2(CT)
0.15 11
n/a
We
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight 218I11 FT=10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP M 31
WEBS 2x4 SP No.3 '
SLIDER Left 2x6 SP No.2 2-10-6. Right 2x6 SP No.2 2.10.5
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-9-3 oc pudins.
BOT CHORD Rigid ceiling directly applied or 7-4-7 oc bracing.
REACTIONS. (size) 1=0-8-0 (min. 0-1-8),11=M-0 (min. 0-1-8)
Max Herz 1=88(LC 10)
Max Upiiftl=-497(LC 5), 11=-097(LC 4)
Max Gmv1=1529(LC 1). 11=1529(LC 1)
FORCES. (Ili - Max CompdMax. Ten. - All forces 250 Qb) or less except when shown.
TOP CHORD 1-2=3301/1099, 2-3=3248/1113, 3-0=28BB/1051, 4-5=2638MOIO, 5-6=3280/1257,
6-7=3280/1257, 7-8=2638/1010, 9-9=288811051, 9-10=324811113, 10-11= 330111099
BOT CHORD 1-18=965/2974, 17-18=965/2974, 16-17=1117/3216, 15-16=1117/3216,
14-15>1115/3216, 13-14=1115/3216, 12-13=96112974, 11-12=-961/2974
WEBS 3-17=403/292, 4.17=-208l782, 6-17=840/361, 7-13=8401361, 8-13=2081782,
9.13=-403/292
NOTES-
1) Unbalanced mot live loads have been considered for this design.
2) Wind: ASCE 7-10; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL-5.Opsf; h=15f ; Cat II; Exp C; End., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcu rent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of vdthstanding 100 lb uplift atjoint(s) except (jt=lb)1=497,
11=497.
LOAD CASE(S) Standard
•Job
Ims's
Type
Oakland Lake - Lot 60
1452-A
A7
ILmss
HIP
jUly
2
IPly
1
Job Reference (ootlona0
SOMM I WW. rL rie=. rL. D4 ]..mu.-wn_r-.-_1......_____I__._.__._....._.....___-. �. ...____.._....______ _ .
ID:EaP0111WCWAO16wSO7VTFdz75cKita496WA97C9KadLe 4fLi c WMe oZh9W92Jey H6_
541-14 9-6-0 17-2-9 24957 32d0 36-11.2 42-0.9
5-0.14 4.62 7-8-9 7� 13 74Y9 45$ 60.14
Dead Load DO. = 51161n
5x7 = 1.5x4 II 34 = 3x4 = 5x7 =
5.00 F12
4 5 6 7 7i 8
Sm
=10OPM
0.0m
5x7= 17 16 15 14 73 12 5x7=
3x5 = 3x4 = 4x6 = 3x8 = 3x4 = Us = 3x4 = W =
1-40
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.38 14-15 >999 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.42 Vert(CT) -0.64 14-15 >772 180
BCLL 0.0 Rep Stress Ina YES WB 0.77 Horz(CT) 0.15 11 n/a n/a
BCDL 10.0 Code FBC20171TP12014 Matrix-S Weight' 21216 FT = 10%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except' TOP CHORD Structural wood sheathing directly applied or 3-0-14 oc pudins.
T2,T3: 2x4 SP M 31 BOT CHORD Rigid calling directly applied or 6-5-11 oc bracing.
BOT CHORD 2x4 SP M 31 WEBS 1 Row at midpt 7-15
WEBS 2x4 SP No.3
SLIDER Left 2x6 SP No.2 2-3-8, Right 2x6 SP No.2 2-3-8
REACTIONS. (size) 1=0-8-0 (min. 0-1-8), 11=0-8-0 (min. 0-1-8)
Max Horz1=73(LC 9)
Max Uplifts �523(LC 5). 11=523(LC 4)
Max Gmvl=1529(LC 1), 11=1529(LC 1)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (Ib) orlass except when shown.
TOP CHORD 1-2--3273/1204, 2�3=3219/1211, 34=304511137, 4-5==-389911574, 5-6=3899/1574,
6-7=389911574, 7-8=3900/1575, 8-9=3046/1136, 9-10=3219/1211, 10.11=3273/1204
BOT CHORD 1-17=10572940, 16-17=-93712793, 1516=937/2793, 14-15=1429/3900,
13-14=9342793, 12-13=-934/2793,11-12=1054/2940
WEBS 3-17=176264,4-17=14/368.4-15=55911341,S15=-434/329, 7-14=4741330,
8-14=560/1342, B-12=14/368. 9-12=176264
NOTES.
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf, h=15f ; Cat II; Exp C; End., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5) Provide mechanical conneclion (by others) of truss to bearing plate capable of withstanding 100lb uplift atloint(s) except at=lb)1=523,
11=523.
LOAD CASE(S) Standard
7x8 O 3x6 =
3x5,= 5x5 = 5x6 = 3x8 = Sx6 = 5x5 =
Dead Load Defl. = 7/16 in
5,5 =
5,5 = 11 7x8 a
o.e —
m
4
Iy
0
42
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL In
(loc) Vdefi Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.82
Ven(LL) 0.68
18 >819 240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.99
Vert(CT) -0.9018-19
>522 180
BCLL 0.0
Rep Stress Ina YES
WB 0.78
Horz(CT) 0.15
15 n/a We
BCDL 10.0
Code FBC2017/rP12014
MatrixS
Welght 226lb FT = 10%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No2'Except
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc pudins.
T2,T4: 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
SOT CHORD 2x4 SP No.2
JOINTS
1 Bras at Jt(s): 10
WEBS 2x4 SP No.3
REACTIONS. (size) 21=0-M (min. 0-1-13), 15=D-M
(min. 0-1-13)
Max Hoa21=81(LC 8)
Max Uplifl2l=-626(LC 8), 15= 485(LC 4)
Max Grav21=1554(LC 1), 15=1554(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=-470/210, 2-3=277911103, 3-5=3806/1587, 5fi6 -4048/1672, 6-7= 4569/1841,
7-8=-4569/1841, 8-9=4024/1556, 9-10=3784H477, 10-12=3784/1477, 12-13=-2768/946,
13-14=-489/190, 3-4=261/119, 11-12=2951140, 9-11=290/126
SOT CHORD 1-21=235/489, 20-21=-316/489, 19-20=-1010/2522, 18-19=1597/4048,
17-18=1481/4024, 16.17=8172509,15-16=217/512, 14.15>217/512
WEBS 2-21=1397/689, 2-20=687/2036, 3-19=67611700, 6-19=-6131364, 6-18=219/577,
7-18=377285, 8-18=315/704, 8-17=6371393, 12-17=741/1755, 13-16=645/2001,
13-15=14011543
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.OpsF h=15ft Cat II; Exp C; End., GCpl=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live bad noncotim ent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atloint(s) except Qt=1b) 21=626,
15=485.
6) Graphical purlin representation does not depict the size or the orientation of the pudin along the top end/or bottom chord.
LOAD CASE(S) Standard
\\\\lll l/////
\GENS���
/ P 5 t1
STA OF 7
i O v` .P I)`IL-I� Az
HIP
5.00 F12 5x7 = 1.Sx4 II
3 22 23 4 24, 25
Us = 4x6 = 1.5x4 II 3x4 = Sx7 =
265 27 6 28 7 29 30 " 318 32 33 9
Dead Load Deff. - 3181n
i WINSPIr
'A
Wwoo-10A
INA,
21 20, 34 35 19 1e 36 37 3817 39 40 41 7642 43 15 14 44 45 46 13 123x5=
3x5 =
Sx5 — 3xB M185H5= 1.5x4 II axe = 3x5 — 5x5 —
3x8= 5x6 WB=
1+
42o
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL
In Coo) Well L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.91
Ver(LL)
0.60 16-17 >787 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.51
I
Ver(CT)
-0.8316-17 >568 180
M18SHS
2441190
BCLL 0.0
Rep Stress Ina NO
WB 0.80
Horz(CT)
0.12 12 n/a Na
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
yyelght 4321b
FT=10%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP M 31
BOT CHORD Rigid ceiling directly applied or 8-2-0 or: bracing.
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (size) 21=041-0 (min. 0-"), 12=1F8-0 (min. 0-1-8)
Max Horz21=57(LC 8)
Max Uplifl21=1298(LC 5). 12=1298(LC 4)
Max Gmv21=2852(LC 1), 12--2852(LC 1)
FORCES. (Ib) - Max. CompJIVI . Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=-7641353, 2-3=5434/2601, 3.22=7744/3791, 22-23=-7743f3791, 4-23=774313791,
4-24=7743/3791, 24-25=7743/3791, 25-26=7743/3791, 5-26=774313791,
5.27=-909714437, 6-27-9097/4437, 6-28=9097/4437, 7-28=9097/4437,
7.29=9097/4437, 29-30=-9097/4437, 30-31=9097/4437, 8-31=9097/4437,
8-32=7764/3797, 3233=-775513797, 933=7755/3797, 9-10=543212600,
10-11=767/359
BOT CHORD 1-21=368f766, 20-21=-4261766, 2034--2311/4943, 34-35=2311/4943,
10.35=231114943, 19-36=-4335/9118, 1&36=-0335/9118, 18-37=4335/9118,
37-38=-033519118,1738=4335/9118, 17-39- 4335/9118, 39-40--4335/9118,
40-41=433519118, 16-01=-4335/9118,16-02=-368"54, 42-43=36827T754,
15-03�3682f7754, 15-04=3682f7754, 14-04--36827754, 14-05=2307/4941,
45-06=230714941, 13-46=2307/4941, 12-13=,374f770, 11-12=374/770
WEBS 2-21=2569/1274, 2-20=199014224, 3-19=157813274, 4-19=5721500, 519=1615/767,
5-17=0/430, 7-16=553/491, &16=745/1578, 8-14=1388/886, 9.14=1587/3289,
10-13=1987/4219, 10.12=2567/1273
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131°x3°) nalls as follows:
Top chords connected as follows: 2x4 -1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x4 -1 row at 0-9-0 oc.
Webs connected as follows: 2x4 -1 row at 0-7-0 oc, Except member 20-2 2x4 -1 row at 0-9-0 oc, member 20-3 2x4 -1 row at 0-9-0 oc, \\`11 I I I +I////
member 19-3 2x4 -1 row at 0-9-0 oc, member 4.19 2x4 -1 now at 0-9-0 oc, member 19-5 2x4- I row at 0-9-0 oc, member 5-17 2x4- 1 row
at G-9-0 oc, member 16-5 2x4 -1 row at 0-9-0 oc, member 7-16 2x4 -1 row, at 0-9-0 oc, member 16-8 2x4 -1 row at 0-9-0 oc, member 8-14.\0 n\ (\fl- 8�
2x4-1 row at 0-9-0 oc, member 14-92x4-1 now at 0-9-0 oc, member 13.92x4-1 row at 0-9-0 oc, member 13-102x4-1 row at 0-9-0
2) All loads are considered equally applied to an plies, except If noted as front (F) or back IS) face in the LOAD CASES) section. Ply to p(z, q �\CE/V&
connections have been pmvided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ABCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psh BCDL=5.OpsF h=1fife, Cat II; Fxp C; End., GPSTIAI)',
11
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water ponding.t
&l%& KT210 plates unless otherwise indicated. -O 1
-p t S/
�0) .c f)-IG-IF-
�NAI
A
o
rlls6
iruss lype
Fly
Oakland Lake -LW 60
1452-A
me
HIP
1 2
Job Reference (optional)
auuu,em cuss , mw d.LJY B UM [1 Zulu vn= a.ZJU a u=21 Lulu MI I eK IOdas m IBG Wed Nov 1412:4227
NOTES-
201a Pe B 2
ID:EaPOUIwCWA016wSO7VTFdz?5cK-dqb?TngEOVeeyLOaUQVf/n_LNiHPc2G477FRQy.PH7w
7) This truss has been designed for a 10.0 psf botom chord five load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 to uplift atjoint(s) except Qt=1b) 21=1298. 12-1298.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)176 lb down and 238 to up at 7-6A, 94 lb down and 139 lb up at 9-6-12. 94 lb
down and 139 ilb up at 11-6-12, 94 lb down and 139 to up at 13-13-12, 94 lb down and 139 lb up at 15-6-12. 94 lb down and 139 lb up at 17-fr12, 94 Ib down and 139 lb up at
19-6-12, 94 lb down and 139 lb up at 21-0-0, 94 lb down and 139 lb up at 22-54, 94 lb down and 139 lb up at 24-54, 94 lb down and 139 lb up at 26-54, 94 to down and 139 lb
up at 28-5-4, 94 to down and 139 lb up at 30-5-1, and 94 lb down and 139 lb up at 32-5-4, and 176 lb down and 238111 up at 34-6-0 on top chord, and 252 lb down and 123 lb up
at 7-&0, 70 lb down at 9-6.12, 70 Ib down at 11-6-12, 70 lb down at 13-6-12, 70 to down at 15-6-12, 70 lb down at 17-6-12, 70 lb down at 19-6-12, 70 lb down at 21-041, 70 lb
down at 22-5 -4, 70 lb down at 24-5-4, 70 lb down at 26-5-4, 70 lb down at 2&5-4, 70 to down at 30-54, and 70 lb down at 32.54, and 252lb down and 123 lb up at 34-5-4 on
bottom chord. The deslgntselection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert 1.9m-54, 3-9=54, 9-11-54, 1-11=20
Concentrated Loads (1b)
Vert 3=129(B) 6=94(B) 9=129(B) 20=252(B)13=252(B) 22=94(B) 23=94(13) 24=94(B) 25=94(B) 26=94(B) 27=94(B) 28=94(B) 29=94(B) 30=94(B) 31=94(B)
32=94(B) 33=94(B) 34=47(B) 35=47(B) 36=47(B) 37=47(B) 38=47(B) 39=47(B) 40=47(B) 41=47(B) 42- 47(B) 43=47(B) 44= 47(B) 45= 47(B) 46=47(B)
84
�P 05 I/)
1�.ti''
_^n % A.
p STA OF 7
zz
/'�'iisONAIN EG\`\���
Dead Load Deft. =118 in
4x4 =
3
Id
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/detl Lid PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) -0.12 1-9 >999 240 MT20 2441190
TCDL 7.0 Lumber DOL 1.25 BC 0.66 Vert(CT) -0.25 1-9 >966 180
BCLL 0.0 Rep Stress [nor YES WB 0.17 Horz(CT) 0.04 6 n/a nla
BCDL 10.0 Code FBC20177fP12014 MatrixS Weight 96 lb FT =10%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 44-0 oc pudins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 841-5 oc bracing.
WEBS 2x4 SP No.3
WEDGE
Left 2x6 SP No.2
SLIDER Right 2x6 SP No.22-9-10
REACTIONS. ,(size) 6=0-B-0 (min. 0-1-8),1=0-8-0 (min. 0-1-8)
Max Ho¢ 1=81(LC 9)
Max Upiinfi=-252(LC 9), 1=-258(LC 8)
Max Grav6=740(LC 1), 1=740(LC 1)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (ib) or less except when shown.
TOP CHORD 1-2=1381/484, 23=1206/440, 3-4=1121/405, 4.5=1215/442, 5-6=-1274/428
BOT CHORD 1-9=45711224, 8-9=204/837, 75=204/837, 6-7=319/1093
WEBS 2-9=-290/272, 3-9=182/449, 3-7=139/329
NOTES.
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0pst h=15ft; Cat II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) This truss haslbeen designed for a 10.0 psf bottom chord live load nonconcunent with any other live leads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at --lb) 6=252,
1=258.
LOAD CASE(S) Standard
M.
`ICEAjs�`T�i
PE.7Q051/ ? �'
STAfro�F r�
I
6-2-7 104D 10-& •.. _ iSi-7 20-4-0
6-2-7 3-9A 08-0 0.6-a 3-a-7 52-9
3x4 =
5x5 = 3z4 =
C
1.0-0 7-11-13 P 13-4-2 20-4-0
r�11_13 Shy 6-11-14
Dead Load per. - V8 in
Plate Offsets ky)_ f
1 0-001 3 21 (1 0 1 14 0-0.21
f3.0-2A 0.2 111
(4.0.2-8 0.3-01
(50-2.0 0-2-111
[8.04-4 0.0.51
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL
in
(loc)
I/de8
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.70
Vart(LL)
-0.12
1-11
>999
240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC
0.66
Vert(CT)
-0.25
1-11
>950
180
BCLL 0.0
Rep Stress Ina YES
WB
0.17
Horz(CT)
0.03
8
n/a
n/a
BCDL 10.0
Code FBC2017/fP12014
.Matrix-S
Weight 95lb Ff=10%
LUMBER -
TOP CHORD 20 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
WEDGE
Left 2x6 SP No.2
SLIDER Right 2x6 SP No.22.9-10
REACTIONS. (size) 8=0-8-0 (min. 0-1A), 1=0-8-0 (min. 0-1-8)
Max Hom 1=-76(LC 9)
Max UpIUt 247(1-C 9), 1=253(LC 8)
Max Grav8=740(LC 1), 1=740(LC 1)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-2-13 oc puriins.
BOT CHORD Rigid ceiling directly applied or 8-10-12 no bracing.
FORCES. (lb) - Max. CompJMax. Ten. - All forces 250 Qb) or less except when shown.
TOP CHORD 1-2=1373/468, 2-3=1204/424, 5-6=1120/391, 6-7=1211/427, 7-8=1268/413,
31=1066/416, 4-6=995/389
BOT CHORD 1-11=-436/1215, 10.11=192/839, 9-10=192/839, 8-9=305/1088
WEBS 2-11=-268/258,4-11=172/436,4-9=131/317
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vesd=124mph; TCDL=4.2psf; BCDL=5.OpsF, h=15R, Cat. 11; Exp C; End., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 par bottom chord live load nonconcument with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 8=247,
1=263.
LOAD CASE(S)i Standard
i
P 5
f
I
STA OF
-5�OT..c
S/�NA� 1ENG\\\\\\
JJob
Truss
was I ype
UNYy
Oaklantl Lake -Lot 60
1452-A
B3
HIP
1
7
Job Reference (optional)
soumem true, FL Pierce, rL., aasm RID:EePOUIwCWAO16wSO7vTFdz75cK-0rOzCpo - - T7idVG6SbeBxkBLK9Nn¢_BEJOJnlpzsy H7v
8-0-0 13-4-0 20-0-0
8.0-0 5-4-0 7-40
LOADING(pso
SPACING-
2-0-0
TCLL
20.0
Plate Gdp DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017ITP12014
LUMBER -
TOP CHORD 2x4 SP No.2 "Except'
T3: 2x6 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
WEDGE
Left: 2x6 SP No.2, Right 2x4 SP No.3
4x4 =
5x7 =
Dead Load Defl. =1/8 in
Us 11
CSI.
DEFL. in
(loc) Well L/d
PLATES GRIP
TC 0.95
Vert(LL) -0.13
1-7 >999 240
MT20 244/190
BC 0.80
Vert(CT) -0.28
1.7 >852 180
WB 0.10
Hom(CT) 0.04
4 We n/a
Matrix-S
Weight 91 lb FT =10%
BRACING-
TOPCHORD
Structural wood sheathing directly applied.
BOT CHORD
Rigid ceiling directly applied or 1U-D-0 oc bracing.
REACTIONS. .(size) 4=0-&D (min. D-1-8), 1=D-B-0 (min. 0-1-8)
Max Harz 1=61(LC 8)
Max Uplift4=228(LC 9). 1=235(LC 8)
Max Gmv4=740(LC 1), 1=740(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=1294/395, 2-3=-1118/408, 3-0=1228/3B0
BOT CHORD 1-7=290/1112, 6-7=-270F1061, 5-0=270/1061, 4-5=273/1056
WEBS 2-7=0/262
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vesd=124mph; TCDL=4.2psf; BCDL=5.0psf; h=15ft; Cat II; Exp C; Encl., GCpl=0.16;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss haslbeen designed for a 10.0 psf bottom chord live load nonooncument with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) except at —lb) 4=228,
1=235.
LOAD CASE(S) Standard
A
Id
N-134 El
� 7
STA OF /
SOT
S0NAI let'
o
Truss
Nss type
y Oakland Lake -Lot 60
4452-A
a4G
HIP
1 1
Jab Reference (optional)
SouNem Truss, FL Pierce, FL.34951 ID:EaPOUlwCWA016wSO7vTFdz?ScK-4ruzCpoT7idVG65beBxkBL --..--08BoOJn�zsy.�H7v
6-0-0 105-0 154-0 21-4-0
6-D-0
07 =
s one
12
1X4 II
13 4 14
15
4x7 =
Dead Load Deli. =1/16 in
Us = 1X4 II 3x4 = 1X4 II 515
3xe =
LOADING
SPACING-
24)-0
C91.
DEFL in
Doc) Well L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.52
Vert(LL) 0.15
9 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.60
Vert(CT) -0.21
9-11 >999 180
BCLL 0.0
Rep Stress Ina
NO
WB 0.26
Hoa(CT) 0.07
7 n/a n1a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 1031b FT o 10%
LUMBER-
BRACING.
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-2.15 oc pudins.
BOT CHORD 2z4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 5-10-13 oc bracing.
WEBS 2x4 SP No.3
SLIDER Left 2x6 SP No-2 2-10-12. Right 2x6 SP No.2 2-10-12
REACTIONS. (size) 1=0.8-0 (min. 0.1-8), 7=0-8-0 (min. 0-1-8)
Max Ho¢1=46(LC 9)
Max Uplift1=-541(LC 8), 7=541(LC 9)
Max Gmv1=1109(LC 1), 7=1109(LC 1)
FORCES. 0b) - Max. CompJMax Ten. -All forces 250 0b) or less except when shown.
TOP CHORD 1-2--2284/1147, 2-3=2213/1160, 3-12=2601/1401, 12-13=2600/1400, 4-13=2600/1400,
4-14=-2600M,100, 14-15=2600I1400, 5-15=2601(1401, 6-6=2213/1160,
6-7=2284/1147
BOT CHORD 1-11=10042041,11.16=-1005/2055, 10-16=1005/2055, 9-10=10052055,
9-17=1004/2055,17-18=10042055, 8-18=1004/2055, 7-8=10032041
WEBS 3-11=28/342, 3-9=347/683, 4-9=453/404, 5-9=347/683, 5-6=29/341
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vesd=124mph; TCDL=4.2psF, BCDL=5.Opst h=15R Cat II; Exp C; End., GCPi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.6D
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except OWb)1=541,
7=641.
6) Hanger(s) or other connection devlods) shall be provided sufficient to support concentrated load(s)121 Ile down and 169 Ib up at 6-0-0, 57
Ib down and 107 Ile up at 8-0-12, 57 lb down and 107 lb up at 10-0-12, 57 to down and 107 lb up at 11-34, and 57 Ile down and 107 to up
at 13-3-4, and 121 lb down and 169 lb up at 154-0 on top chord, and 1061b down and 10016 up at 6-0-0, 41 lb down at 8-0-12, 41 It,
down at 10-0-12, 41 Ib down at 11-3-4, and 41 Ile down at 13-3-4, and 106 lb down and 100lb up at 15-4-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard \
1) Dead
+Roof s Live (balanced): Lumber Increase=125, Plate Increase=1.25 \��\ \A\J M
a
Vert 1-3=54, 3-5=54, 5-7=54, 1-7=20 \���. \CENS��`����
Concentrated Loads (lb) _
Vert 3 74(B) 5=74(B)10=27(B)11=106(B) 8=106(B)12-55(B)13=55(B)14=55(B) 15=55(B) 16=27(B) 17=18�-27= i P O$
/ l
J\.
�-O STA OF
pp��,c 1l-IG-I� iry��
44 =
.Dead Load Deb. = 31161n
Ib
LOADING(psf)
SPACING-
2i
CS'.
DEFL in
(IOC) Udell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
.25
TC 0.72
Vert(LL) -0.17
1-6 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.73
Vert(CT) .0.35
1-6 >558 180
BCLL 0.0
Rep Stress Ina
YES
WB 0.16
Horz(CT) 0.02
5 n/a n/a
BCDL 10.0
Code FBC20177TPI2014
Matrix-S
Weight: 67 lb FT = 10%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 4-3-12 no pudins, except
BOT CHORD 2x4 SP No.2
end verticals.
WEBS 2x4 SP No.3 'Except*
BOT CHORD
Rigid ceiling directly applied or 9-5-14 oc bracing.
W3: 2x6 SP No.2
WEDGE
Left: 2x6 SP No.2
REACTIONS. (size) 5=0-8-0 (min. 0-1.8), 1=D-BA (min. 0-1-8)
Max H0
rz1=86(LC B)
Marc Upl8t5=-206(LC 9), 1=-213(LC 8)
Max Gmv5=608(LC 1),1=608(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1054/388, 23=814/280, 3-0=-866/254, 4-5=530/246
BOT CHORD 1-7=377/928, 6-7=377/928, 6-6=1711717
WEBS 2-6=3031248, 3-6=-45/409
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vesd=124mph; TCDL=4.2pst BCDL=S.DpA h=15ft; Cat. II; Exp C; Encl., GCpi=0.1 B;
MWFRS (envelope% Lumber DOL=1.60 plate gdp DOL=1.60
3) This truss hasbeen designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads.
4) Provide mochardad connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift atjoint(s) except QI=Ib) 5=206,
1=213.
LOAD CASE(S) Standard
Dead Load D.H. - 31161n
3x4 = tx4 II
3 4
5 3x4 =
1-0-0 9-0.0 17-0-0
1N kH 7-6-r1 8 0-0
Plate Offsets, C/Y)--f1•D-0-013-21
f1.0-1-140-0-21
13:0-2-00-2-111
f5:0-2-00-2-111
f6.0-0-40-2-01
LOADING(psQ
SPACING- 24)-0
CSI.
bEFL
in
Ooc)
Vdell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.59
Vert(LL)
-0.17
1-8
>999
240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
i
BC
0.72
Vert(CT)
.0.36
1-B
>541
180
BCLL 0.0
Rep Stress Ina YES
WB
0.15
Horz(CT)
0.02
7
n/a
me
BCDL 10.0
Code FBC2017RPI2014
Matrix-S
Weight 6711a FT=10%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3 *Except' BOT CHORD
W3: 2x6 SP No.2
WEDGE
Left: 2x6 SP No.2
REACTIONS. (size) 7=0-&0 (min. 0-1-8), 1=0-B-0 (min. 0-1-8)
Max Horz 1=78(LC 8)
Max Uplitt7=197(LC 9), 1=205(1-C 8)
Max Gmv7=608(LC 1), 1=608(LC 1)
FORCES. Ob) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1041/362, 2-3=828/264, 5-6=889242, 6-7=-526/235, 3-0=7441273,
4-5=744/273
BOT CHORD 1-9=346/914, 8-9--346/914, 7.8=164f744
WEBS 2-8=-281219, 4-8 =28/398
Structural Wood sheathing directly applied or 6.0-2 oc puriins, except
end verticals.
Rigid calling directly applied or 9-1 D-14 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuh-160mph (3-second gust) Vasd=124mph; TCDL=4.2W, BCDL=5.Opsh h=15f ; CaL II; Exp C; End., GCpl=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other Ilve loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 to uplift atjoint(s) except (It -lb) 7=197,
1=205.
LOAD CASE(5) Standard
M-
f t
�ro 1t STA .OF
Z'
4x7 =
12 13
44 =
Dead Load Den. = Us in
LOADING(psf)
SPACING- 2-0-0
CSL
DEFL. in (too) I/de8 Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.78
Vert(LL) 0.21 B-10 >892 240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.55
Vert(CT) -0.31 8-10 >602 180
BCLL 0.0
Rep Stress Ina NO
WB 0.11
Horz(CT) 0.02 7 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight 721b FT=10%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 3-7-9 oc puriins.
T2: 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 9-6-11 oc bracing.
BOT CHORD 2x4 SP M 31
WEBS 2x4 SP No.3
REACTIONS. (size) 11=0.8.0 (min. 0-1-8), 7=0-8-0 (min. 0-1.8)
Max Horz 11=46(LC 8)
Max Upliftl1=462(LC 8), 7=-462(LC 9)
Max Gmv11=928(LC 1), 7=928(LC 1)
FORCES. (lb) -,Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD it-2=1198/606, 2.3=1356f721, 3-12=1192/683, 12-13=11921683, 4-13=11921683,
4-5=1356f720, 5-6=11981606
BOT CHORD 1-11=59211184, 10-11=606111B4, 9-1D=-60411192, 9-14=6D4/1192, 8-14=-6D4/1192,
7-8=-592/1184, 6-7=592/1184
WEBS 2-11=463/318, 3-10=01285, 4.8=0/284, 5-7=463/318
NOTES-
1) Unbalanced mof live loads have been considered for this design.
2) Wind: ASCE 7-10; VulM 60mph (3-second gust) Vasd=124mph; TCDL=42psf; BCDL=5.Dpsf; h=15ft; Cat. 8; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.B0 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcunant with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)11=462,
7=462.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)121 lb down and 169 to up at 6-0-0, 55
lb down and 107 lb up at 8-0-12, and 55lb down and 107 lb up at 9.11.4, and 121 lb down and 169 lb up at 12-0-0 on top chord, and 106
lb down and 100 lb up at 6-0-0, 41 lb down at 8-0-12, and 41 to down at 9-114, and 106lb down and 100 Ib up at 11-114 on bottom
Chord. The design/selection of such connection device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S)I Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert 1-3=-54, 34=54, 4-6=5411-6=20
Concentrated! Loads (lb)
Vert 3=74(F) 4=74(F) 9=27(F) 10=106(F) 8=106(F)12=55(F)13=55(F)14-27(F)
P OS \
r 1
1 I
�rt.n I
b 1` STA E OF 7
C) a r)-J&-($ i ¢�
S'ONA� �Et'
a
5611
LOADING(psf)
TOLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Ina NO
Code FBC2017rrP12014
CSI.
TO 0.38
BC 0.35
WB 0.06
Matdx-P
DEFL in
Ven(LL) -0.07
Vert(CT) -0.09
Horz(CT) -0.02
(Ioc) Vdefi L/d
6-7 >999 240
6-7 >834 180
4 We We
PLATES GRIP
MT20 2441190
Weight 30 lb FT = 10%
LUMBER-
TOP CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP NO2
BOT CHORD
Rigid telling directly applied or 10-0-0 oc bracing.
WEBS 20 SP No.3
REACTIONS. (size) 4=Mechanical, 5=Mechanical, 7=0-11-5 (min. 0-1-8)
Max Horz7=123(LC 4)
Max UpliR4=59(1-C 4), 5=57(LC 4), 7=166(LC 20)
Max Gmv4=95(LC 17), 5=108(LC 1), 7=254(LC 1)
FORCES. (Ib) - Max. CompJMax, Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=42psf; BCDL=5.Opsf; h=1A Cat It Exp C; Enck G54M 8;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss hasibeen designed for a 10.0 pat bottom chord live load nonconcunent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to beating plate capable of withstanding 100 lb uplift atjoint(s) 4, 5 except at --lb) 7=166.
5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 30 lb down and 110lb up at 2-11-0, 30
lb down and 11101b up at 2-11.0, and 261b down and 52 lb up at 5-8-15, and 26lb down and 52lb up at 5-8-15 on top chord, and 71 lb up
at 2.11-0, 71 lb up at 2-11-0, and 5lb down and 2lb up at 5.8.15, and 5lb down and 2lb up at 5-8-15 an bottom chord. The
design/selection of such connection device(s) is the responsibility of others,
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) iStandard
1) Dead + Roof Live (balanced): Lumber Increase=125, Plate Increase=125
Uniform Loads (pit)
Vert 1-4=-54, 1-5=20
Concentrated Loads Ila)
Vert B-72(F=38,B=36)10=94(F=47,B=47)
\tM. B� //
r 1
STA OF r
0��
OR 10 P'\��\���
o
russ
NssType
y Oakland ake - Lot 60
1452-A
CJ7
JACK
2 1
Job Reference o Lionel
SouNem Truss, K. Platte, YL, :14901
LOADING(psf) SPACING- 2.0-0
CSI.
DEFL in
(Ioc) I/deft Ud
PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25
TC 0.45
Vert(LL) -0.04
6-7 >999 240
MT20 2441190
TCDL 7.0 Lumber DOL 1.25
BC 0.43
Vert(CT) -0.08
6-7 >999 180
BCLL 0.0 Rep Stress Incr NO
WB 0.16
Hom(CT) -0.03
4 n/a We
BCDL 10.0 Code FBC2017rTP12014
Matrix-S
Weight 41 lb FT= 10%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 1"-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 4=Mechanical, 5=Mechanical, 8=0.11-5 (min. 0-1-8)
Max HoR6=153(LC 4)
Max Upllft4=94(LC 4), 5=104(LC 4), 8=-186(LC 4)
Max Grav4=111(LC 1), 5=234(LC 1). 8=481(1-C 1)
FORCES. (Ib) - Max Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=381/115, 2-9=-443/159, 3-9=394/169
BOT CHORD 1-8=1081383, 8.11=-249/383, 7-11=249/383, 7-02=249/383, 6-12=249/363
WEBS 2-8=-303/190, 3-6=-431/281
NOTES-
1) Wind: ASCE 7.10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=15ft; Cat. II; Exp C; End., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 '
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=1b) 5=104,
8=186.
5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentratedload(s) 23 lb down and 38 lb up at 5-0-7. 23 lb
down and 38 lb up at 5-0-7, and 51 lb down and 93 lb up at 7-10-6, and 51 to down and 93 lb up at 7-10-6 on top chord, and 4 Ib up at
5-0-7, 4 lb up at 5-0-7, and 21 lb dawn at 7-10-6, and 21 lb down at 7-10-6 on bottom chord. The design/selection of such connection
device(s) is the responsibility of others.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S)i,Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Invease=1.25
Uniform Load's (plf)
Vert: 1-4=54, 1-5=20
Concentrated Loads (lb)
Vert: 10=-39(F=19, 13=19)12=24(F=12,.B=12)
0
Job
Truss
rum fype
y
Oaldand Lake-Lot60
1452-A
J1
JACK
4 1
Jab Reference (Optional)
SWUM I MSG. YL Pierce, tL., 8 Ub1 nun: a.LJU S vaLl euln rnnc LL2JU S Um Li OUIU MI J ex lnoumnm, lnc, vvea Nov 191zRt:]l [ule .1
10:EePOWrH7sLH.0_B
1-6-0
1-6-0
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL
In
floc)
I/deft.
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.06
Vart(LL)
0.00
1
n/r
120
TCDL 7.0
Lumber DOL
1.25
SC 0.02
Vert(CT)
-0.00
1
rdr
120
BCLL 0.0
Rep Stress Ina
YES
WB 0.00
Horz(CT)
0.00
We
We
BCDL 10.0
Code FBC20171TP12014
Matrx-p
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
REACTIONS. !(size) 2=Mechanical, 3=0-8-0 (min. 0-1-8)
Max Horz2=124(1-C 1), 3>124(LC 1)
Max Upl'If12=54(1-C 8)
Max Gmv2=95(LC 1), 3=29(LC 3)
FORCES. (lb) - Max Comp./Max Ten. - All forces 250 (lb) or less except when shown.
PLATES GRIP
MT20 244/190
Weight 5lb FT=10%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 1-6.0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 6-D-0 oc bradng.
NOTES-
1) Wind: ASCE 7i 10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=1 Sit Cat. II; Exp C; Encl., GCpi=D.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss hasbeen designed for a 10.0 psi bottom chord live load nonconcument with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 2.
5) Non Standard bearing condition. Review required.
LOAD CASE(5) Standard
LIGEIJS��'\'r���
P 5
1
lob Truss i suss Type y.. Oakland Lake - Lot 69
1452-A J2 JACK 8 i
Job Reference (ppt'pna0
Swfi,.. TNss, FL Pierce, FL, 34951 Run: 6.230 s Cd 212018 Pd m e.230 s Oct 212U19 MI I ek Indusbift Ine. We Nov 412.42,31 2018 Per 1
ID:EaPOUIW CWA016 W SO7VTFdz?5cK-U036grgLld?47ZBApJVRprysO_A7LhFs?15TaBy9H7
1-4-0
1-0-0 WO
l)-&0
1
LOADING(psQ
SPACING- 2-0-0
CSI.
DEFL, in
(loc)
I/deb
Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.07
Ven(LL) 0.00
5
>999
240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.06
Vert(CT) 0.00
5
>999
180
BCLL 0.0
Rep Stress Incr YES
WB 0.02
Hom(CT) -0.00
3
We
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 7lb FT =10%
LUMBER- BRACING -
TOP CHORD 2x4 SP No2 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins.
BOT CHORD 2z4 SP No2 SOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (sae) 3=Mechanical, 4--Mechanical, 5=0-8-0 (min. 0-1-8)
Max Hom5113(LC 8)
Max Uplift3=34(LC 1), 4=-43(LC 1), 5=66(LC 8)
Max Gmv4=5(LC 8), 5=223(LC 1)
FORCES. Qb) - Max Comp.IMax. Ten. - All forces 250 (lb) or lass except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCOL=4.2psf; BCDL=5.Opsh h=15ft; Cat. II; Exp C; End., GCpl=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 ,
2) This truss has been designed for a 10.0 psi bottom chord live load nonconcument with any other live loads.
3) Refer to girders) for truss to buss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of wfthstanding 100 lb uplift at joint(s) 3, 4, S.
LOAD CASE(S)Ztandard
\\PN `M- e< //���i
/
4\CE/us� \'� i
P 05 �1
Y/� t
1 STA EE OF ice=
o
ruse
truss ype y Oaklard Lake - Lot 60
1452-A
J3
JACK 4 1
Job Reference (optional)
soumem I mss, M neree, tl, :14a>l
IVRLe.2aab Iaznzmernvco.nwc,rnn <oiomneemousme BAp VRpzyvv_BBLbar auro ra ai
ID:FaPOUIwCWAO16w507vTFdz75cK-U036gryLId747ZBApJVRpzysE_BBLb9s?I5TeBy H7s
Plate Offsets ()(,Y)— 12:0-0.12,0.1-121.
I2:0.1.11,1.2.81,15:0-0-0,0-1-121
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL
In
goo)
gdefl
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.08
Vert(-L)
0.00
5
>999
240
MT20
2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.06
Vert(CT)
0.00
5
>999
180
BCLL 0.0
Rep Stress Ina YES
WB 0.03
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017frP12014
Matrix-P
Weight 12 lb
FT=10%
LUMBER -
TOP CHORD 2x4 SP No.2
SOT CHORD 2x4 SP N0.2
WEBS 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 4=Mechanical, 5=0-B-0 (min. 0-1-6)
Max Horz5=72(LC 8)
Max UpIM3=-48(LC 8), 5=62(LC 8)
Max Grav3=38(LC 1), 4=28(LC 3), 5=208(LC 1)
FORCES. (lb) - Max Comp./Max Ten. -AII forces 250 (Ih) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-6-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=1SN Cat II; Exp C; Encl., GCpl=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonmricurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) 3, 5.
LOAD CASE(S) Standard
M. g/�F�q/'/
i P
STA OF
OR
11 ;_
r
='� y
�OT� q fI-IL-I� ilV��
PCs<
�I
o
"es
mss ype
y
OaWand Lake -Lot 60
1452-A
J4
JACK
e i
Job Reference o donel _
oaumem , mss, I.D:E.POUI_._.__._......._.______._.__._....._.....____.__...
ID:EaPOUIw4-D-0 wSO7vTFdz75cK•UO36grgLId7472BApJVRprys6_A6Lb4s715TaBy H7s
1-4-0 4-0-0
1
LOADING(psf) SPACING- 2-0-0 CSI. 13EFL. in (loc) Well Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) -0.00 4-5 >999 240 MT20 2441190
TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 45 >999 180
BCLL 0.0 Rep Stress Inv YES WB 0.03 Horz(CT) -0.00 3 n/a n/a
BCDL 10.0 Code FBC2017ITP12014 Matdx-P Weight 13lb FT=10%
LUMBER- BRACING -
TOP CHORD 2z4 SP No2 TOP CHORD Structural wood sheathing directly applied or 4-0.0 oc pudins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 4=1VIechanical, 5=0-0-0 (min. 0-1-8)
Max Horz5=83(LC e)
Max Upllft3=-59(LC 8), 5=66(LC 8)
Max Grav3=54(LC 1), 4=40(LC 3), 5=220(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf, h=15ft; Cat. II; Exp C; Encl., GCpl=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 It, uplift at joint(s) 3, 5.
LOAD CASE(S)i Standard
Job
Truss
I mss I ype
Qty
oakland Lake-Lot6o
1452-A
JS
JACK
4
jlj1Y
1
Job Reference o 8onal
__._.__._......._______. _. __._..... _.....___-.__ ..._ ..__.._. .. ._. _.____ _
ID:EaPOUIwCVVA016WS07vTFdz76CK-ycdU2Brz3w7>v)m N1 OgMBU770V_4227EPr06di H7r
i 4 0 6-6-0
1.4-0 { 4-2-0
LOADING(psi) SPACING- 2-0-0 CSI. DEFL. in Qoc)/daft Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Ver L) -0.01 4.6 >999 240 MT20 2441190
TCDL 7.0 Lumber DOL 1.25 BC 0.15 Vert(CT) -0.02 4-5 >999 180
BCLL 0.0 Rep Stress Ina YES WB 0.05 Hoa(CT) -0.01 3 nla Na
BCDL 10.0 Code FBC2017ITP12014 Matrix-P Weight 18 lb FT= 10%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-6-0 oc pudlns.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 4=Mechanical, 5=0-8-0 (min. 0-1-8)
Max Horz5=113(LC 8)
Max Uplift3=93(LC 8), 5-80(LC 8)
Max Grav3=96(LC 1), 4=71(LC 3), 5=267(LC 1)
FORCES. (lb) - Max. Comp.lMax. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; End., GCpl=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psl bottom chord live load nonancument with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to beating plate capable of withstanding 100lb uplift atjoint(s) 3, 5.
LOAD CASE(S) Standard
M.
1
1t STA OF /
Job Imes mw ypeUW Fly OaNan Lake-Lot60
1452-A J58 MONO TRUSS 2 1
Job Reference (ootiona0
southe�Ft Pierre, FL, M951 Run. aPos wC 212ma Pnnt 7vT s Os1212a19 MTek 3w7) I Inc Wed NOV 1412.420? 2019 Page 1
ID:EaPOUIwCWA016w507vTFdz75cK-YedU2BrCiw7xljMMN10gMBU7pOVk4207EPN6dyJH i
1d-0 5-8-0 _ i
1-0-0 i 4-4-0
LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) Vdefl L/d PLATES GRIP
TCLL 20.0 Plate Gdp DOL 1.25 TC 0.22 Vert(LL) 0.02 4-5 >999 240 MT20 2441190
TCDL 7.0 Lumber DOL 1.25 BC 0.17 Vert(CT) -0.03 4-5 >999 180
BCLL 0.0 Rep Stress Ina YES WB 0.05 Horz(CT) -0.02 3 n/a n/a
BCDL 10.0 Code FBC2017/TPI2014 Matrix-P Weight 18 lb FT = 10%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-8-0 oc purins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (sae) 3=Mechanical, 4=Mechanical, 5--04B-0 (min. D-1-8)
Max HorzS=117(LC 8)
Max Upli13=97(1-C 8), 5=81(LC 8)
Max Gmv3=100(LC 1), 4=75(LC 3), 5=272(LC 1)
FORCES. (Ib) - Max. CompJlvl . Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2ps(; BCDL=5.Opsh h=1510 Cat. II; Exp C; End., GCpl=0A8;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss hasibeen designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 3, 5.
LOAD CASE(S) Standard
� 1 STA (DF' '/ Z:
�R W
oTruss
Inuss lype
y
OaMand LeXe - Lot 60
1452-A
J6
JACK
10
1
Job Reference (optional)
Southern Truss , Ft Pierce, FL., 34951
Plate Offsets (X,Y)- 12:0-0.12
0-1-121 I5:0-1-8 1-2-01
15:0-0-0
D-1-121
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL. in
00c)
Vdefi
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TO 0.26
Vert(LL) -0.02
4-5
>999
240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.20
Vert(CT) -0.04
4-5
>999
180
BCLL 0.0
Rep Stress Ina YES
WB 0.06
Horz(CT) -0.02
3
n/a
Na
BCDL 10.01
Code FBC20171TP12014
Matrix-P
Weight 191b FT = 10%
LUMBER- BRACING -
TOP CHORD 2z4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2z4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing.
WEBS 2z4 SP No.3
REACTIONS. (size) 3=Mechanical, 4=Mechanical, 5=0-8-D (min. 0-1-8)
Max Horz5=124(LC 8)
Max Uplift3=104(LC 8), 5=85(LC 8)
Max Grav3=109(LC 1), 4=81(LC 3), 5=283(LC 1)
FORCES. (Ib) -.Max. Corrp./Max. Ten. -AII forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opst; h=15ft; Cat 11; Exp C; Encl., GCpl=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girders) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (It -lb) 3=104.
LOAD CASE(S) Standard
Job
Inlss
Nss Type
Qty Fly Oakland a - Lot 60
1452-A
J7
JACK
15 t
Job Reference o tlonal
Soulhem Truss, FL Pierce, FL, 3 551
M
nun: .':ID a. 11 Tula M Vu s V neuie.'en If1aY6u,Cl, mC rvwnur,»,a.»a.aa cu,o reyo,
ID:EaPOUIWCWA016WS07vTFdZ75cK-ycdU20rY F41' MNIDgMBUxJORE41b7EPrOSdyJH7r
DII
1-0-0 7-6-0
t-n.n I 6-s-0
Dead Load Defi. - the In
Plate Offsets (XY)-12:0-D-120.1-12115:0-1-81-2-01
f5-D.0-00-1-121
LOADING(Psf)
SPACING- 2-0-0
C51.
DEFL In
(loc)
Udefl
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.51
Vert(LL) 0.07
4-5
>978
240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC
0.39
Vert(CT) -0.13
4.5
>569
180
BCLL 0.0
Rep Stress Incr YES
WB
0.08
Horz(CT) -0.05
3
n/a
nla
BCDL 10.0
Code FBC2017/fP12014
Matrix-P
Weight 24 lb
FF=10
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 4=Mechanlcal, 5=0-8-0 (min. 0-1-8)
Max Horz5=155(LC 8)
Meer UpIM3=136(LC 8). 5=101(LC 8)
Meek Gmv3=148(LC 1), 4=11O(LC 3), 5=335(LC 1)
FORCES. (lb) - Max. CompJMax Ten. - A0 forces 250 (Ib) or less except when shown.
WEBS 2-5=2951272
BRACING -
TOP CHORD Structural wood sheathing dlrectly applied or B-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing.
NOTES-
1) Wind: ASCE 7.10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCD1-=5.0psf, h=151t; Cat. II; Exp C; Encl., GCp1=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrenl with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (1-I1h) 3=136,
5=101.
LOAD CASE(S) Standard
Joe
Truss
I ruse I ype
Qty PP.oakleMLake-Lotsm
1452-A-
MV2
VALLEY
2 1
Job Reference o Oonal
s nnR-2 2
3
2x4
I
LOADING(psi)
TCLL 20.0
TCDL 7.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
CSI.
TC D.D4
BC 0.03
DEFL
Vert(LL)
Vert(CT)
In Doc)
Na -
Na -
Ildes
Na
Na
Ud
999
999
PLATES GRIP
MT20 244/190
BCLL 0.0
Rep Stress Ina YES
WE Elm
Harz(CT)
-0.00 2
We
nfa
BCDL 10.0
Code FBC2017/fP12014
Matrix-P
Weight 5lb FT=10%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0.0 oc puriins.
BOT CHORD 20 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 0o bracing. I
REACTIONS. (sae) 1=2.0-0 (min. 0-1-8), 2-2-0-0 (min. 0-1-8), 3=2-0-0 (min. 0-1.8)
Max Horz 1=26(LC 8)
Max Uplift1=14(LC 8), 2=31(LC 8) i
Max Gmvl=47(LC 1), 2=34(LC 1).3=25(LC 3)
FORCES. (Ib) - Max. CompJMax Ten. - All forces 250 (lb) or less except when shown.
NOTES.
1) Wind: ASCE 7.10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.0W,, h=1511; Cat. II; Exp C; End., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurent with any other live loads.
4) Bearing at joint(s) 2 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 It, uplift atjoint(s) 1, 2.
LOAD CASE(S) Standard
PE 605
- i
l sr/�U
OF i =
� 1 STA E OF /
oRloP-�����
� � p
I
I
2'
3
I
2z4
1.5z4 II
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
In goc)
Well
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.25
Vert(LL)
nla— -
Na
999
MT20 2441190
TCDL 7.0
Lumber DOL
1.25
BC 0.19
Vert(CT)
n!a -
nla
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
nla
We
BCDL 10.0
Code FBC20171TP12014
Matrix-P
Weight 13lb FT= 10%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0.0 oc puriins, except
BOT CHORD 2x4 SP No.3 and verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 1=4-0-0 (min. 0-1-8),3=4-0-0 (min. 0-1-8)
Max Horzt=S4(LC 8)
Max Uplift1=35(LC 8), 3=-62(LC 8)
Max Gmv1=116(LC 1), 3=116(LC 1)
FORCES. (lb) - Max. CompJMam Ten. - All forces 250 gb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vesd=124mph; TCDL=4.2psf; BCDL=S.Opsf, h=15R; Cat II; Exp C; Encl., GCpF-0.18;
MWFRS (envelope); Lumber DOL=1.60 plate gdp DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This Was has, been designed for a 10.0 psf bottom chord live load nonwricurrem with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at)oint(s) 1, 3.
LOAD CASE(S)'Standard
�1t STATE OF
URIDP:
Job
ruse
I nlss i ype UTY My OananCLexe-Lot6a
14M-A
We
VALLEY 2 1
I
Job Reference (optional)
wumem i mss, r� rierm. r�., .wno,
ID:FaPOUIwCWA016w5O7vTFdz75cK-OpBsFW'bgEGoMtLYxkXwOl2cnlwpV59T3aae3y H7q
2
3
2r4 i 1.5x4 II
I
LOADING(psf)
SPACING- 241-0
CSL
DEFL in Qoc) Vdefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.73
Vert(LL) n/a - We 999
MT20 2441190
TCDL 7.0
LumberDOL 1.25
BC 0.56
Vert(CT) n/a - n/a 999
BCLL 0.0
Rep Suess Ina YES
WB 0.00
Hmz(CT) 0.00 n/a rda
BCDL 10.0
Code FBC2017ITP12014
Matrix-P
Weight 20lb FT=10%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structure] wood sheathing directly applied or 6-0-0 oc pudins, except
BOT CHORD 2X4 SP No.3
end verticals.
WEBS 2X4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 104)-0 oc bracing.
REACTIONS. (size) 1=6-0-0 (min. 0.1-8), 3=6-" (min. 0-")
Max Hors 1=105(LC 8)
Max UplifH=57(LC 8), 3=101(LC 8)
Max Grav1=190(LC 1), 3=190(1-C 1)
FORCES. Qb) - Max. CompJMax. Ten. - Ali forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vesd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=151K Cat II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except at --lb) 3=101.
LOAD CASE(S) Standard
r
51_
i PlEal it
STAOFi-7 .
`� ORID
i I ENG \\\\
�a I