Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEDEC 17 '9418 I FORM R405-2017 IriT, h4iFla g4FlF) t Pti'mitting J FLORIDA ENE FICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 040 F1452 A RHG - W Builder Name: Ryan Homes SCANNED Street: 5361 Oakland Lake Cir. Peril Office: St. Lucie City, State, Zip: Ft. Pierce , FL , Permit Number: BY 1 owner. Ryan Homes Jurisdiction: 661000 St Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) `Y 1. New construction or edsdng New (From Plans) 9. Wall Types(1516.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R-4.1 1265.30 ft2 b. Frame - Wood, Adjacent R=11.0 251.33 ft2 3. Number of units, if multiple family 1 c. WA R. nz 14. Number of Bedrooms 3 d. WA R- IF 10. Ceiling Types (1452.0 sgft.) Insulation Area 15. Is thisawowt case? No a. Under Attic (Vented) R=30.0 1452.00 1`12 6. Conditioned floor area above grade (W) 1452 b. NIA R- fP Conditioned floor area below grade (W) 0 c. WA R- ft' 11. Ducts R fP 7. Windows(132.0 sgft.) Description Area a. Sup: Attic, Rat: Main, AH: Main 6 290.4 a. U-Factor. Dbl, U=0.54 98.67 flz SHGC: SHGC=0.31 b. U-Factor. Dbl, U-0.63 33.33 1`12 12. Cooling systems kBtWhr Efficiency SHGC: SHGC=0.32 a. Central Unit 23.2 SEER:14:00 c. U-Factor. WA fP SHGC: 13. Heatingsystems k8tumr Efficiency d. U-Factor. WA ft2 a. Electric Heat Pump 23.2 HSPFd8:20 SHGC: Area Weighted Average overhang Depth: 1.000 i4 Area Weighted Average SHGC: 0.313 14. Hot water systems a. Electric Cap: 50 gallons 8. Flcor Types (1452.0 sqft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1452.00 nz b. Conservation features b. WA R= ft2 None c. WA R= ftr 15. Credits Pstat Glass/Floor Area: 0.091 Total Proposed Modified Loads: 49.82 PASS SS Total Baseline Loads: 51.13 1 hereby certify that the plans and specifications covered by Review of the plans and QISE Srgp this calculation are in compliance with the Florida Energy specifications covered by this ,y� U fBpA Code. calculation Indicates compliancef=7+r.� with the Florida Energy Code. /+ ro,,.; '• •'�- -: O PREPARE Yb ' Before construction is completed r DATE: q�rl I this building will be Inspected for 9 P compliance with Section 553.908 l7 .' � 1, I hereby certify that this building, as designed, is in compliance Florida Statutes. 'With the Florida Ener de. COb typ,Tr- OWNERIAGENTa BUILDING OFFICIAL: DATE: I DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliancerequires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNETIICC 380, Is not greater than 0.050 an for whole house. 11/12f2018 2:01 PM EnergyGauge® USA Section.R405.4.1 Compliant Software Page 1 of 4 I � _ [�3a FILE COPY 910Z8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Tifle: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 040 F1452 A RHG - W Bedrooms: 3 User Conditioned Area: 1452 Ryan Homes Total Stories: i 1 Worst Case: No Ryan Homes Rotate Angle: 0 St. Lucie Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot# 40 Blcck/Subdivtslon: Oakland lake PlatBook: Street: 5361 Oakland Lake Cir. County: St Lucie City, State, Zip: Ft. Pierce, FL, CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Tamp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fod Pierce FL_VERO_SEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Blockl 1452 12632A SPACES Number Name Area Volume ICtchen Occupants Bedrooms InfiI ID Rnlshed Cooled Heated 1 Main 1452 12632.4 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 146 If o 1452 ft' 0.29 0 0.71 ROOF V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emltt Deck Pitch Tested Tested Insul. (deg) 1 Hip Composition shingles 1573112 0 ft2 Dark 0.5 N 0.5 No 0 22.6 ATTIC # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Vented 300 1452 fP N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1452 h' 0.1 Wood 11/1212018 2:01 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS AdJacent Space Cavity Width P R_VvL,o Fr In Fr Height In Area Sheathing Framing Solar Below R-Yalnf-,acttnn ahenr.-G -1 2 -3 -4 5 S W N E - Exterior Concrete Block- Int Insul Main Exterior Concrete Block- Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block- Int Insul Main Garage Frame -Wood Main 4.1 37 6 8 4.1 21 0 8 4.1 47 6 8 4.1 40 0 8 11 29 0 8. 8 325.0 ft2 8 182.0112 6 411.7 ff2 8 346.7 ft2 8 251.3 ft2 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0. 0.25 0.5 0 0 0 0 0 DOORS # Dad Door Type Space Storms U-Value Ft Width Height In R In Area 1 2 W Insulated Main - Wood Main None None .4 3 .46 2 5 8 8 201P 16 112 WINDOWS Odentation shown Is the entered, Proposed orientation. V # Wall Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 S 1 Metal Low-E Double Yes W 2 Metal Low-E Double Yes N 3 Metal Low-E Double Yes E 4 Metal Low-E Double Yes E 4 Metal Law-E Double Yes 0.54 0.31 N 0.54 0.31 N 0.54 0.31 N 0.54 0.31 N 0.63 0.32 N 16.4 ft2 1 00 in 16.4112 11101n 16.4 ft2 1 It O in 49.3 ft2 1 ft 0 in 33.3 IF 1 ft 0 in 2 ft0 in Drapes/blinds 2ft01n Drapestblinds 2 ft 0 In Drapes/blinds 2 It 0 In Drapes/blinds 2 It 0 In None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 393 fP 393 ft2 6411 8.7 It 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000387 1473.8 80.91 152.16 .2875 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Heat Pumpf Split HSPF:8.2 23.2 kBturnr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitf Split SEER: 14 23.2 kBtu/hr 696 cfm 0.75 1 sys#1 11/12/2018 2:01 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Ced If Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF Heat Cool 1 Attic 6 290A ft Main 72.6 ft2 Proposed On Main — clan 72.6 cfm 0.05 0.50 1 1 TEMPERATURES Programable Thermostat Y Ceiling Fans: C;ooing Jan Heating ng � Jean Feb � Feb 6 Mar �X r � � Me � Jun Jul � Aug � Sep � OctrD0' Nov Dec � Dece MMar Apr May Jun Jul Aug Sep Oct [ ]X Nov Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WO) AM 78 78 78 78 78 78 78 78 80 80 60 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 76 78 78 76 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 66' 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEF) 68 68 68 68 PM 68 68 68 68 6688 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 ibsrs .ft. 0 ft2 0 ft 0.3 Main Name: Test Rater Rating Compant: Test Rater Signature: 11/12/2018 2:01 PM EnergyGaugeO USA Section 1i405.4.1 Compliant Sofhvare Page 4 of 4 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 5361 Oakland Lake Cir. Permit Number: Ft. Pierce , FL , MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory). The bulifing official shag require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Rodda law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains Information Indicating the energy performance level and efficiencies of components Installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R4024 Alr leakage (Mandatory). The building thermal envelope shall be constructed to fimit air leakage in accordance with the requirements of Sections R402A.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402A.1 Building thermal emreloillbe buildingthermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shag allow for differential expansion and contraction. Fi R402A.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be Installed In accordance with the manufacturers instructions and the aiteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third parry shall Inspect all components and verify compliance. ❑ R402A.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour In Climate Zones 1 and 2, and three air changes per hour In Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNETlICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either Individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 4B9.105(3)(0, (g) or (I) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repalrs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stave doors shall be closed, but not sealed, beyond the intended weatherstripping or other Infiltration control measures. 2. Dampers Including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, If Installed at the time of the test, shag be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if Installed at the time of the test, shall be turned off. 6. Supply and return registers, It Installed at the time of the lest, shall be hilly open. R40242 Freplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and fisted for We fireplace. Where using tight -fitting doom on masonry fireplaces, the doors shall be listed and labeled In accordance with UL 907. El R402A.3 Fenestmgon air leakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 dim per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (26 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA I01/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 11//212018 2:01 PM EnergyCauge® USA - FBC 61h Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, Isolated from Inside the thermal envelope. Such rooms shall be sealed and insulated In accordance with the envelope requirements of Table R402.1.2, where the wells, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed.and any water lines and ducts In the room Insulated In accordance with Section R403. The combustion air duct shall be insulated where it passes through conditaned space to a minimum of R-B. Exceptions: 1. Direct vent appliances with both Intake and exhaust pipes Installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section Rl006 of the Florida Building Gods. Residential. ❑ R402A5 Recessed lighting. Recessed luminaires Installed In the building thermal envelope shag be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested In accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wait or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.13 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary elenxrictes'sFance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the healing load. ❑ R403.32 Seating (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways far air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed In accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet dud tightness criteria below. Dud lightness shall be verifted by testing to accordance with ANSVRESNETACC 380 by either individuals as defined In Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth In Section 489.105(3)(9, (g) or (i), Florida Statutes, to be'substan8ally leak free' In accordance with Section R403.3.3. ❑ R40332.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design aldlow rate when tested In accordance with ASHRAE 193. 1 ❑ R40332 Dud testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough -In lest: Total leakage shall be measured with a pressure differential of 0.1 Inch w.g. (25 Pa) across the system, including the manufacturers air handier enclosure B Inslailed at the time of the test. All registers shag be taped or otherwise sealed during the test. 2. Postconstmction test: Total leakage shall be measured with a pressure differential of 0.1 Inch w.g. (25 Pa) across the entire system. Including the manufacturers air handler enclosure. Registers shag be taped or otherwise sealed during the test. Fxceptlons: 1. A duo air leakage test shag not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing Is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shag be signed by the party conducting the test and provided to the code official. []R4032.5 Building cavities (Mandatory). Buftding fuming cavities shall not ba used as duds or plenums. ❑R4MA Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105OF (41 °C) or below 55,F (13°C) shall be insulated to a mirdmum of R-3. El caused Protection of piping Insulation. Piping insulation exposed to weather shall be protected from damage. Including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R4035.1 Heated water circulation and temperature malntenarnee systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R4D3.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. 11403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump: The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the Idemiflpation of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water In the circulation loop is at the desired temperature and when there Is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy Input to the heat tracing to maintain the desired water temperature in the piping In accordance 'with the times when heated water Is used in the Occupancy. 11/12/2018 2:01 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 2 of 6 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the Inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'h Inches (89 mm) in the hot water distribution line and cold water line located as dose as possible to the storage tank. 11403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the Intended use. The minimum temperature setting range shall be from 10(rF to 140OF (38°C to 600C). R403.5.6.12 Shut down. A separate switch or a dearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water -hearing systems to be turned off. R403S.62 Water -heating egdipmenL Water -hearing equipment Installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment Installed. Equipment used to provide heating functions as part of a combination system shall sa0sfyall stated requirements for the appropriate water -heating category. Solar water heaters shall meal the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors In Installed solar water -heating systems should meet the followingcriteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air Intakes and exhausts shall have automatic or gravity dampers that dose when the ventilation system Is not operating. Fi R403.&1 Whole -house mechanical ventilation system tan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception,, Where whole -house mechanical ventilation fans am integral to tested and listed HVAC equipment, theyshall be powered by an electronically commutated motor. ❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive Indoor pressure or for mechanical ventilation shag meet the following' criteria., 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. i 2.. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, cmwlspaces,'attached enclosed garages'or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air Is drawn from enclosed spaoe(s); then the walls of the space(s) from which air is drawn shall be Insulated to a minimum of R-11 and the calling shall be Insulated: to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatary). R403.7.1 Equlprriont sizing. Heating and cooling equipment shag be sized In accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J another approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and Indoor units Qf split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described In Section R302.1. This Code does not allow designer safety factors, provisions for future expanslon or other factors that affect equipment sizing. System sizing calculations shall not Include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is Installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW MINIMUM A MINIMUM EFFICACY M ETT) AIRFLOW RATE MAXMU (OFM) Range hoods Any 2.8 cfMwatt Any In -line fan Any 2.8 chn/watt Any Bathroom, utility room 10 1.4 cfm/watt c90 Bathroom, utility room i 90 2.8 dm/watt Any For 8I:1 cfm - 28.3 L/min. & When tested in accordance with HVI Standard 916 11/12/2018 2:01 PM EnegyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that Its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent bad. The published value for AHRI total capacity Is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturet's expanded performance data shall be used to select cooing -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the bad calculation (or entering water temperature forwatersoume equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bum and dry-bulb temperatures shall be for the Indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains Ifthe return duct(s) Is installed in an unconditioned space. Exceptions: 1. Attached single- and mulliple-famly residential equipment string may be selected so that Its cooling capacity Is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sear by a Rorida-registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1all Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall riot be more than 1.15 tunes greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ 11403.7.12.2 Electric resistance furnaces. Electric resistance furnaces shag be sized within 4 kW of the design requirements calculated a000rdng to the procedure selected in Section R403.7.1. ❑ R403.7.1.23 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric Minters shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an Intermittent basis, such as anticipated additional bads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system Is utilized to provide cooling or healing to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods Is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC--Commercial Provisions In lieu of Section R403. ❑ R4039 Snow, melt and Ice system controls (Mandatory) Snow- and Ice -melting systems, supplied through energy service to the building, shag Include automatic controls capable of shutting off the system when the pavement temperature Is above 50°F (10°C), and no precipitation Is falling and an automatic or manual control that will allow shutoff when the outdoor temperature Is above 40OF (4.8'C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through 11408.105. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that Is an Integral pad of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat Such switches shag be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning Ignition pilots. ❑ R403.102 Tlme switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be In compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. P. Pumps that operate solar -and waste -heal -recovery pool heating systems. 3. Where pumps are powered exclusively from on -she renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at ❑ the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season. Is from she -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant meansshag not be required. R403.10.4 Gas- and all -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shag have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after Apol 16. 2013, when tested In accordance with ANSI Z 21.56. Pool heaters tired by natural or LP gas shall not have continuously burning pilot lights. ii 11/12/2018 2d11 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Hest pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested In accordance with AHRI 1160. Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable. spas (Mendator)Qhe energy consumption of electdc,powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS ❑ R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps In permanently installed lighting fixtures shall he high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage righting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 11/12/2018 2:01 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location 8 insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Main 3. No. of units (it multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 23.2 a) Split system SEER 14.0 5. Is this a worst case? (yesrno) 5. No b) Single package SEER c) Ground/Water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1452 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.563 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.313 14. Heating system: Capacity 23.2 c) Area 7c. 132.0 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) Be. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 16. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 b) Gas fired, natural gas EF 10. Wail type and Insulation: c) Gas fired, LPG EF A. Exterior.. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (insulation Ft -value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multaone cooling credit d) Radiant barrier Installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be Installed (or exceeded) in this home before final Inspection. Otherwise, a new EPL display can) will be c�pleted based on installed code compliant features. Lo�Builder Signature: Date: \ zi Address of New Home: 5361 Oakland Lake Cir. City/FL Zip: Ft. Pierce, FL 11/1212018 2:01:26 PM EnergyGaugeO USA 6:0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 040 F1452 A RHG - W Bullder Name: Ryan Homes Street: 5361 Oakland Lake Ch. Permit Office: St. Lucie City, State, Zip: Ft. Pierce, FL, Permit Number: v Owner: Ryan Homes Jurisdiction: 661000 W r Design Location: FL, Fort Pierce c> COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrlershall be Installed In the building envelope. Air -permeable Insulation shall. requirements The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. Breaks or joints In the air barrier shall be sealed. Cellinglattic The air barrier In any dropped catIng/soffit shall be aligned with The Insulation in any dropped ceiling/soffit the Insulation and any gaps In the air border shall be sealed, shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be Insulated by completely filling the cavity sealed. with a material having a thermal resistance of R3 Knee walls shall be sealed. per Inch minimum. Exterior thermal envelope Insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air border. Rim joists shall be Insulated. Floors The air barrier shall be Installed at any exposed edge of Floor framing cavity Insulation shall be Installed to (Including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and canfllevered shall be permitted to be in contact with the tap side floors) of sheathing, or continuous Insulation installed on ' the underside of floor framing and extends from the bottom to the tap of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor Insulation, Insulation a Class I vapor retarder with overlapping joints taped, shall be permanently attached to the crawlspace Shafts, penetrations Duct shahs, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts In narrow cavlUes shall be cut to fit, or narrow Narrow cavities cavities shall be filled by Insulation that on Installation readily conforms to the available cavity spaces. Garage separation Alr sealing shall be provided between the garage and conditioned spac 2s. Recessed Ilghting Recessed light fixtures Installed In the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing In exterior walls, or Insulation that on Installation readily conforms to available space shall Showerltub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be Insulated. Electrical/phone box or The air border shall be Installed behind electrical or communication extedorwalls boxes or air -sealed boxes shall be Installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill volds between fire spr1likier cover 121mon alid wells or callings. a. in addition, inspection or log wan5 snan oe in accomance Wim me provisions of IIX:-400. 11/12/2018 2:01 PM EnergyGauge® USA FBC 61h Edition (2017) Compliant Software Page 1 of 1 -F t wrightsoft-, Project Summary Entire House One Stop Cooling and Heating 7225SanLn CuutWirterPark FL32792P1om:(407)629-6920 Fu:(407)629-9307 Web:~.OMSbpC4olhgMmLbeme:CA0032444 For 5361 Oakland Lake Cir., Ft. Pierce, FL Notes: Weather: Fort Pierce, FL, US Job: lot 040 F1452 ARHG - W Dale: 06106/2018 By. RVMC Winter Design Conditions Summer Design Conditions Outsidedb 42 OF Oulsidecib 90 OF Insidedb 6B OF Insidedb 72 OF DesignTD 26 OF Design TO 18 OF Dallyrange M Relative humidity 50 % MoisMecOfference 68 grAb i Heating Summary Sensible Cooling Equipment Load Sizing Structure 15406 Bnuh Structure 13810 Bl uh Ducts 2627 Bhuh Ducts 2813 Btuh Central vent (0 dm) 0 Btuh Central vent (0 cfm) 0 Btuh e) Humitllfirg6on 0 Btuh Blower 0 BOA Equipment Btu load 18032 Btuh Use manufacturer's data n Rate/swingg multipplier 025 Btuh Infiltration Equipmerffsensrbleload 15792 Method Simplified Latent Cooling Equipment Load Sizing lion all ConshAvee rag Fireplaces Structure 3035 Btuh cts Ceentr 690 �h CI vent (0 c1m) HeatIng Cooll g (none) 453 la Equipment latent load 3734 Btuh %blu me (" 12639 12639 Airrhanges/hour 0.45 023 Equipment Total Load(Sen+Lat) 19525 Btuh Equiv. AVVFF (dm) 95 48 Req. total rapacity at 0.755 SHR 1.8 ton Heating Equipment Summary i Cooling Equipment Summary Make Goodman M(�n• Make Goodman Mfpp. Trade GOODMAN;&NITROL;AMANADISTI... Trade GOODMAN;JANITROL;AMANADISTI... i Model GSZ140241K Cond GSZ140241K AHRI ref 7995055 Coil ARUF25B14A AHRI ref 7995055 Eifidency 82 HSPF Eifiden(y 11.5 EER,14 &dsibleoocling SEER Heatinginput 17400 Btuh Heatlngoutput, 23200 Btuh @47°F Latent000ling 5800 Btuh Temperature rise 27 OF Total cooling 23200 Biuh AcMurflow 773 do Actual airflow 773 dm Alrflowfadar 0.043 dmfth Airflowfactor 0.047 dm/Btrih Wepressure 0.50 In H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Capacity balance point= 36 OF lnpcut� 9 kW, Output =29982 Bhuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 81h Ed. W rlgh�t9otL` 2018•Wv-1213 Ri9t45U1e®lYive�1201816a31 RSU16677 Papa age I _43a9mpWE,WPWNNn1040F14S2AflHG-Wnp Cek.KS FMdDwfbWM W wrightsoft- Right-M Worksheet Entire House One Stop Cooling and Heating 7225 Sardsmw Go4Wlder Park FL32792 Ptore:(407)629-6920 Far.(407)629-9307 Web:v...OmSbpCoofirOmmLiwrse:CAC032444 Job: Lot 040 P1452 ARHG-W Da10: 06/06/2018 Br: R17MC 1 Room came StwHousa DW 2 EpoS.dvall 146.0 ft 205 ft 3 Room height 87 0 d 07 ft heat4a01 4 Roamdmertlons 11D x 95 ft 5 Room area 1452E IF 1045 LF Ty CCamsecm ud U-value Or HIM Area aper0n� Load t (BULW-9 (B1rtsM9 m perim�r (0) Ph) a M) (Mh) Ham Cool Gros MMPS Heal Cool Gross NIPS Heat Cod 6 W �G 13A-4= 0.143 n 372 26 2 413 397 1476 1039 83 83 907 216 4A5-2xn 05W n 14D4 1436 16 0 229 235 0 0 0 0 13AA= Q143 a 372 252 348 265 987 695 96 62 231 163 4A5-2om 0540 a 104 34.14 49 0 6BB 1674 0 0 0 0 11 4A5-2omd OL630 a 1638 4209 34 0 549 1410 34 0 549 1410 W 13A-0ps 0.143 a 372 252 326 310 1152 611 0 0 0 0 Y-C 4A5-2xn 0540 a 14D4 1426 16 16 229 235 0 0 0 0 y7L44ts 13A- 0.143 w 3.72 2.62 183 146 544 383 a 0 0 0 ��D3 4Ai2om D540 w 14D4 34.14 16 0 229 658 0 0 0 0 11DO 0390 w 10.14 1150 20 27 2D4 231 0 0 0 0 fl �--D 12Dosv OB91 - 237 123 252 M6 559 314 0 0 0 0 i1DO 0.390 n 10.14 1150 16 16 162 104 0 0 0 0 C 16830ad 0.032 - 083 1.70 1453 1453 1209 2464 105 105 87 177 F 27h1prn 1.18O - 305E ODO 14M 146 447E 0 105 21 629 0 6 c)AM waxdm 0 a Emelopabsgdn 12697 10231 18M 1965 12 0) b00rafim b) RaomwALadan 2709 958 380 135 0 0 0 0 13 htemalgains Dmrpan6® 230 4 920 0 0 AppOanmsbfw 1700 0 8uhbt3l Qines6b13) 15406 13810 2183 2100 Loscodamellmd 0 0 0 0 Lr flsOander 0 0 0 0 RedshWal 0 0 0 0 14 15 DLdbaSubbb] udbads 17% 2W. 15406 2527 13810 2813 1791 2D% 2183 372 2100 428 Total room load krrWcd(dm) IBM 16623 I 2556 252E r 773 7MM 110 118 Calculatonsaooroved byACCAtD meet all requirements of Manual J 8th Ed UI6M2018 WA2135120 RgHS RHO -Wap Ca1c.MJ8 FRSDoorfa _rDesbopREM11P PR01N.0t040 F7452A FMO-Wnp Gala=MG Frar4 DoerhresW Page I wrightsoftRight-M Worksheet Entim House One Stop Cooling and Heating 7225Sard=w Cool,WlrterParKFL32792PhDm:(407)629-6920Fax:(407)629.9307 Web:w OmSbpCooOrgmmUmc :CAC032444 Job: WOO F1452 ARHG-W Date: 06/06/2018 ay: RVMC 1 R=rwne GREAT Mein 2 EVosdwall 14A 0 MO 0 3 Rcom MOM 8.7 a hedbwl 6.7 0 hmVbod 4 Roan dm rdom 1.0 x 29H 0 1.0 x 227.0 0 5 Room area 298.0 W 227.0 IF Ty g01L&Udm 11-\due `F) Or HTM Arm (fl')) Load A— (R) load number (BUIM B71trfi� a pod,ebr (t) fth) a Pedmebr (q (09A)) Hsat Cad Gross r41P19 Heat Caul trots NP)S Hem Cool 6 W as 13Ad 0.143 n 372 262 0 0 0 0 0 0 0 0 �--(i 05-2arn 0540 n 14A4 1436 0 0 0 0 0 0 0 0 13A-4= 0.143 a 3.72 20 122 89 331 233 131 114 424 299 4AS-2om 0540 a 104 34.14 33 0 459 1116 16 0 229 558 11 4A5-2omd 0.690 a 1638 4209 0 0 0 0 0 0 0 0 t13A4= 0.143 s 972 262 0 0 0 0 131 114 424 299 —C 4A5-20M 0540 s 14.04 14.36 0 0 0 0 16 16 229 235 W 13A-40M 0.143 w 3.72 252 0 0 0 0 0 0 0 0 L�DG 4A -2am 0540 w 14A4 34.14 0 0 0 0 0 0 0 0 11D0 03N w 10.14 1150 0 0 0 0 0 0 0 0 fl g—D 12DOW Om - 237 133 0 0 0 0 0 0 0 0 11D0 CM n 10.14 1150 0 0 0 0 0 0 0 0 C 16330ad 0.032 - 093 1.70 296 296 246 505 227 227 189 385 F 22Ak4n 1.180 - 3056 OAO 296 14 430 0 2V 30 ma 0 61 o)AED exardon 196 -116 Elope bmbaln 1469 2)51 2417 1657 12 a) Ir5 don 260 92 557 197 b) Rcomlenl)9on 0 0 0 0 13 k&mal gains Cmrpan5(91 230 0 0 2 460 App9anoash9la 0 0 Subrohl Qires6b13) 17V 2143 M74 M14 Le erWma)load 0 0 0 0 La tar¢fer 0 0 0 0 Redsbhufim 20O 320 0 0 14 &bb3td 1927 2463 2974 2114 15 Dudbads 17% 21Y 329 502 17Ye 27% 507 471 Tod mom bad 2256 2964 30 2785 AIrre4Wred (dm) 97 136 149 130 J - -- Calculationsappmved byACCAb meetall requirements of Manual J 81h Ed - • rwN9htaoTt• 201&W W 2195ge 2 RigHAFHG.ldvema120c.WS 1RSp16677 Paget .-`DedaaP\TEMP PRWPLaI040 Fl452A RHO-Wnp Calc-MI6 Frod Ocor hoes W +wrigntsoft Right-M Worksheet Job: LM040 F1452 ARHG-W DatEntire House RIIMC 018 Sr.By. /MC One Stop Cooling and Heating 72259ard=mCCut,Widar Padr.FL32792Phore:(407)629-6920Fax:(407)629-9307 Web:w OmSbpOooOrg=mUwme:CAC032444 1 Roomr a W1' PAN 2 6posedwa8 9.0 ft 4D ft 3 Room height 87 It hoat4nol 8.7 R heaVbool 4 Room dimensom 1D ■ 126.1 It 1D x 169 ft 5 Room area 126.1 IF 169 0.r Ty Conshdoa (M Load comber (e1MP+) (Blrhff) Perimm (ft)(BAm) oar�Pedmalar (a) (Btrh) Heat Cod Cross NIPS .Heat Cad Grom NRS Heal Caul 6 W MRAGM 0.143 n 3.72 222 78 78 291 205 35 35 12B 91 1--CI 4A5.20m 05M n 14D4 1436 0 0 0 0 a a 0 0 13A4= 0.143 a 3.72 2.62 0 0 0 0 0 0 0 0 4A-r2xn 0540 a 1404 34.14 0 0 0 0 0 0 0 0 11 4A5-2xid 0630 a 16M 42D9 0 0 0 0 0 0 0 0 W 19A400s 0.143 a 372 222 0 0 0 0 0 0 0 0 —G 4AS2m 0540 a 14D4 1439 0 0 0 0 0 0 0 0 13A4= CA43 w 3.72 262 0 0 0 0 0 0 0 0 4A5-2wn 0540 w 14D4 34.14 0 0 0 0 0 0 0 0 11D0 02% w 10.14 1150 0 0 0 0 0 0 0 0 H 12G�v 0.W7 - 237 139 0 0 0 0 0 0 0 0 11DO a= n 10.14 fl50 0 0 0 0 0 0 0 0 --.D c 16330ad 0.032 Om 1.70 126 120 105 214 17 17 14 29 F 22h1pm 1.180 - 3050 010 121 9 276 0 11 4 121 0 6 4AEDexpudon -81 -7 Emelopalossign 672 337 266 113 12 a) 110aa80n 197 59 74 26 b) Room%erAMm 0 0 0 0 13 F6emal9alm Om parbe 230 0 0 0 0 Appianmsb9mr 1200 0 StbbbI (Um6b 13) 839 1596 340 139 Imesmalbad 0 0 0 0 lestrander 0 0 0 6 RedsTt0E0n 3 6 0 0 14 Subtotal 842 1602 340 1M 15 Oedloads 17% 20% 144 326 17% 2(ik 58 29 Total room load i 1 Airmqua ed(dm) 42 g8 6 Calculatlons approved bvACCAto meet all requirements of Manual J ft Fd .ri9ixls - Riglt-8UWOLrFersel20l818.031 RSLhGBT7 201e-Ww121 Pai20 o3 _V3ftP1TEMPPRINNuto40F1452ARHG-Wnp CHIC-MM Rod Cbarfm&W 9 wrightsoft Right-J® Worksheet Entire House One Stop Cooling and Heating 7225Sa,d=�Cmn Wlrtel Park FL32792Ptom:(407)629-6920Faz(407)629.9307 Web:v OmSbpODOflM=m Uwm:CAO032444 Jab: WOO F1452ARHG-W Date: OW0612018 By. ROMC 1 RoOmr a MWID N1317H 2 6pOSEdv4l 0 ft 12D ft 3 ROOmlmlgtd 87 ft Imtbool d7 ft heaVmd 4 Rmmdme.da 8D x 7D 2 1D x 1075 ft 5 ROomerea 56.0 (P 1075 If Ty Cau9udw U- Ae Or HTM Area (re) toad Area (T) 1md r Mtff (BbIVff) a Pemnebr (0) (Mh) ar *meW M (BNh) Heat Cod G} WP5 Heat Cod Gloss NOS Heat Cool 6 W �G 13AAM 0.143 n 322 2W 0 0 0 0 0 0 0 0 4AS2xn 0540 n 14D4 1436 0 0 0 0 0 0 0 0 13A-4= 0.143 a 372 2E2 0 0 0 0 0 0 0 0 4AS2om 0540 a 104 34.14 0 0 0 0 0 0 0 0 11 4AS2omd OAO a 163a 4209 0 0 0 0 0 0 0 0 W 134A= 0.143 6 3n 222 0 0 0 0 104 IN 388 273 T--G 4AS2xn 0540 a 14D4 1438 0 0 0 0 0 0 0 0 W 13AA= 0.143 w 372 2E2 0 0 0 0 0 0 0 0 4AS2 M 0540 w 14Di 34.14 0 0 0 0 0 0 0 0 11----DG 11DO 0390 w 10.14 1150 0 0 0 0 0 0 0 0 N 12DOsv Ow- 237 133 70 70 165 92 65 65 154 87 r—D IIDO 0390 n 10.14 1150 0 0 0 0 0 0 0 0 C 16630ad 0.032 - 033 1.70 56 56 47 95 108 108 89 182 F 22Atrn 1.180 - 3DE8 NO 56 0 0 0 10B 12 368 0 6 4AMwn dm .9 -30 STMopelosWn 211 178 1000 512 12 e) lydbalan 0 0 223 79 b) Ram mall n 0 0 0 0 13 htemalgalm Onpards@ 230 0 0 0 p 0 0 SLfzbbl(rulas6b 13) 211 178 1223 591 lesexbmalbad 0 0 0 0 leatetdm 0 0 0 0 ReclistbAon 62 369 0 0 14 96bb1 273 548 1223 Sg1 15 Dulloads 17°/ 20% 47 112 17"/ . 208 120 Tod man load 319 659 1431 711 Alrrequtred(dm) 14 31 61 33 Cala)lations approved byACCA to meet all requirements of Manual J ft Ed. c #=�.1g~��. R �8-rbI3 1a125120 RgtlSUHG-WAsa1201.RJS FRSU16B77 Page4 JDe94apITFMP PiiDYP1o1040 FI452A f310-WnP Cak-MO! FrortDOOrlamS W wrightsoft' Right-J® Worksheet Entire House One Stop Cooling and Heating 72255arde CoMWWrPe44FL32792PIum:(407)629-6920 Fa (407)629-9307 Web:w OmStopCoo9rDmmLlme ;CA0032444 Jab: LDt O40 F1452ARHG•W Data: OW0612018 By: RUMC 1 Ro iin 8IH2 2 EPosedwan 0 9 0 a 3 ROom heigh a7 4 heaVmol a7 0 hoaVmol 4 ROomdmerdom 55 x 4D 8 55 x 85 O 5 Rp Brea 22.0 W 46B IF Ty CWnw anstrurdm UAeke Or (8uhgp-'F) (BIdViF) a pedmebr (W (Bull) a pedmebr M (Muh) Heat Caol Lips upr. Heat Cool Dias WP5 Heat Cod 6 W 13A4as (1143 n 372 0 0 0 0 0 0 0 0 Y-G 4Asam 0540 n 14D4 uas 0 0 0 0 0 a 0 0 13A-4ars 0.143 a 3.72 2B2 0 0 0 a 0 0 0 0 4Ab2xn 054D a 104 34.14 0 a 0 0 0 0 0 0 1i 47s-2omd 0m0 a ism 42D9 0 0 0 0 0 0 0 0 13A4as 0.143 a 372 2R 0 0 0 0 0 0 0 D 4A52an 0540 a 104 1436 0 0 0 0 0 0 0 0 13440M OL143 w 372 2B2 0 0 0 0 0 0 0 0 4AS-20M 0540 w 14D4 34.14 0 0 0 0 0 0 0 0 1100 0390 w 10.14 11.50 0 0 0 0 0 a 0 0 �--D12OOsv OD91 - 237 13i 0 0 a 0 0 0 0 0 11DO 03M n 10.14 115D 0 0 0 0 0 0 0 0 C 161330ad O= - OB3 1.70 22 22 18 37 47 47 39 79 F 22A-prn 1.180 - 30B8 Ow 22 0 0 0 47 0 0 0 6 co AMwxJm -2 -4 Erndopelos4ain 18 36 39 75 12 a) WOalm 0 0 0 0 b) Rmmw labon 0 (3 0 0 13 Irdemal galm: Om.panb@ 230 0 0 0 0 AAYovmbeg 0 0 Sbot31(ines6b13) 18 36 39 75 Lesse)k+rlload 0 0 0 0 (M78r5M 0 0 0 0 Red shibUM -18 S6 511 314 14 Subutd 0 0 511 469 15 DuDtoads 17% 20% 0 0 17% 23% 91 96 TaW roan load Ah1e4Wred(ft) o a Calailafions approved byACCA to meet all requirements of Manual J 8th Ed wrri9l�boR� F6gHSdu815hersa1201818D310.SU16877 2018-tbw121351d'.0 _rDadmpITEMPPRNrLO2040F1452A151q-Wnp Cak=M0 Fm D"rawT W page +� wrightsoft• Right-J® Worksheet Entire House One Stop Cooling and Heating 7225SaTd eCaut.Wirter ParKF1.32792Ptnm:(407)629.692OFax(4D7)629-93D7 Web:w OmSbpC4a9rgmm LbDM:0AC032444 Job: Lot 040 F1452 ARHG-W Date: WOMB By: RVMC 1 Roomr a LDRY BED3 Oft 14D 0 3 R haWd 0.7 B hrathDol 6.7 D 1ga[mI 4 5 RDomdmerda Room area 35 x 7D 0 245 IF 11D x 14D 0 154D IF Ty Consmdon rumba U-valve (813u P9 Or HTM (BNM Ama OF) w penmen (0) load (Baa1) Area (M a Pedmemr (Q Load (BWI) Heal Cod Gross NIPS Heal Cool Gras WPS Heat Cool 6 W l--G 13A4oa 042xn 13A-4oa C143 0540 0.143 n n a 372 14,04 3.72 2B2 1436 2.62 0 0 0 0 0 0 0 0 0 0 0 0 122 16 0 105 0 0 392 229 0 276 235 0 11 4A5-2xn 4AS-2vnd 0540 OMO a a - 109 1638 34.14 42W 0 0 0 0 0 0 0 0 0 0 0 D 0 0 0 0 LY Y-G Vjl 13AAM 4K2om 13AAms OL143 05w Q143 s. s w an 104 3.72 2S2 1438 262 0 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a a 0 IL 4AS�n 11DO 0540 0290 w w 14D7 10.14 30.14 11.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a R" 12C-OSv 0D91 - 237 133 30 30 72 40 0 0 0 0 11DO 16B30ad 0390 OD32 n - 10.14 033 1150 1.70 0 25 0 25 0 20 0 42 0 154 0 154 0 12B 0 251 C F 22A-pm 1.180 - Sam ODD 25 0 0 0 164 14 430 0 61 c)AED emnsim 1 -28 -53 Enebpabss♦3aln 92 54 1179 719 12 a) mBaaaon 0 0 ffiD 92 b) ReomwWm 0 0 0 0 13 FdemalgLus: CmparM@ 230 0 0 1 230 Appr--bma 500 0 9QAOW(0res61313) 92 554 1439 1041 Lesoleadload 0 0 0 0 14 lestars(er RecLmbufm SAWW 0 -92 0 0 -554 0 0 %6 1585 0 112 1153 151 Dudbads 17°/ 20% 0 0 1Ly, 21% 270 235 Tetal iaad MmgNred(�) 0 0 O 0 1855 60 1388 65 Calmuladons approved byACCAto meet all requirements of Manual J Bm Ed. ' ' wrlg!-rsofC 201844�12135120 Ri0I1SdIWIillersa1201B 1BD31 RSU18877 Pages _VedWPWEU.PPRNTU1O4OF1452AFHG-Wnp Cat -WO FMdDwrtme5 W 9 wrightsoft• Right-M Worksheet Entire House One Stop Cooling and Heating 72256ardsnve CCutWinerPaAKR32792PMre:(407(629-6920Fas(407)629-9307 Web:w OmSbpODolrOmmLke�:CA0032444 Job: Lot 040 P1452ARHG-W Date: 06/06/2018 By: RUM 1 RP tame B®2 FOY 2 Bpn dwan 37.0 ft 55 ft 3 Roan hdgft fl7 ft leattnd fl7 ft heattn01 4 Roan dmerdas 155 x 11D ft ID x 99.0 It 5 Pmii 170.5 IF 99D IF Ty Cmmh dm ll\xhxi Or HTM Area (1F) load Area Load number (Bc►VIP-4j @UM a pometr W (BLh) a pedm� (0) (BLh) Heat Cool Cans WP5 Heal Cod G= WP5 Heal Cool 6 % �--0 1SA40m 0.143 , n 3.72 2D2 96 96 355 250 0 0 0 0 4Arr2xn 0540 n 14JM 14M 0 0 0 0 0 0 0 0 13A-4= 0.143 a 3.72 262 0 0 0 0 0 0 0 0 4AS-2om 0540 a 14.04 34.14 0 0 0 0 0 0 0 0 i t 4A&20md 0.630 a 1638 4209 0 0 0 0 0 0 0 0 W 13P,4= 0.143 s an 2.62 91 91 340 239 0 0 0 0 --G 4A52mn 0540 s 14D4 1436 0 0 0 0 0 0 g 0 4y 13A4= 0.143 w 3.72 262 135 119 441 310 46 26 103 73 4A5.20m ONO w 14D4 34.14 16 0 229 558 0 0 0 0 L�OC, 11DO D390 w 10.14 1150 0 0 0 0 21 20 204 231 L12COsn OD91 - 237 133 0 0 0 0 B7 71 168 94 11DO 03M n 10.14 11 0 0 0 0 16 16 162 1B4 —D C 168-Wad O.OM - OB3 1.70 171 171 142 289 99 99 e2 168 F 29A-{xn Use - 30D8 am 171 37 1135 0 99 6 169 0 6 QA®enuslon 1751 1 98 B-Icpa ba/gan 2649 1822 888 712 12 b 68a 243 100 3( Ram ve Com 0 0 0 0 13 Obpral paint OmrpabCm 230 1 MO 0 0 ApoWmsbtff 0 0 Sfi01al(fues6b13) 3329 22M 990 748 te6ae12=dbed 0 0 0 0 lea5e� 0 0 0 0 PedsuWw 180 136 -990 -748 14 Sib-53W 509 2430 15 Dudbas 1 20% 598 495 17-A 20% 0 0 Tohlmombad 4107 2925 0 0 Akmgimd(dn) 176 136 0 0 Calatlatlons approved byACCA to meet all requirements of Manual J 8th Ed 201$ tb*12135120 1452A HO-Wersa12 c.MIB31 rtD76877 Page7 _\Ded4aP\TFNP PRNILLa 040 F1452A RHG-WnP CaIC-MI6 kM OOW pees W 3 $a C E E E u H 3 F G E� _g 8 =H99§ pH Dp pm O O O O O n n_ C �'c o4400R44RR4 �5 O)ui0 o nN00000 00TQIW OT OT OT rO innroncny�y��c�yny��cZo �� ❑� x x x x x x x x x LLLLLL LLLLLLLLLLLLLLLL 55555555555 xc = o�(ox Oxx o�((O�((O�((0XX x00xx0�( 0 0 0 0 0 0 0 0 0 0 0 00000000000 �LL. oR�N�V 'af o00 0000000 T E�'t3 LLL O G U 0mm U.0 z a mma w s m 0 V' Return Branch Detail Table Name Grille Sze (in) Htg (cftn) Gg (cfm) TEL (ft) Design FR WIoc (fpm) Diam (n) H x W (in) SWNJoist Opening (in) Duct Mat Trunk rbi Ox0 1 773 773 0 1 0 0 0 Ox 0 VIFx +. waghtSoft- 2818-Nb 1213512D HIgftSdtAW rsaI281878D2IRA)18 Papal �.rl� _�Ded0DpYrWPWM1LOI84p F1452AR43-Wnp Calc.AQ FrMDDorfacw: W Static Pressure and Friction Rate Job: Lot0ARHG-W -�' wrightsoft' 0319: orilos12no18 Entire House By. RUAIo One Stop Cooling and Heating 722SSard o CmKWkrtwPark FL32792PInna:(407)629-6920 Fac(407)629-9307 Web:xwxomSbpCooUmmmLk e; .rAC032444 Project Information For: Ryan Homes 5361 Oakland lake Cir., Ft Pierce, FL Heating Cooling (tn H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Retum grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Otherdevice 0 0 Available stalk; pressure 0.34 0.34 'Total. Supply Return (it) (it) Measured length of run -out 12 0 Measured length of trunk 12 0 Equivalent length of fittings 110 0 Total length Total effective length 134 Heating (In/100ft) 0.253 >0.18 0253 >0.18 Fitting Equivalent Length Details supply 4X--35,11A20,11G=5,11G=5,11G=5,1A-35,11G=5:Total EA10 Return TbWE 0 134 Cooling (In1100ft) 0.253 >0.18 0,253 >0.18 wrlghtsoft- 201844ow12135120 •...•, .m.—.e+. ftttSWb®UimM201818-031FLSU16877 Page 1 _Nlla9ropRF7W PWMLLnl040 F1452AFWG-Wnp Cale=Mfe fiorl Lbol tarasW Level 1 Da 10X10 2W tOX6 69 cfm FBB 1 1 W cfm 6" 6' GREAT KIT 6' 10X6 5' 1lz1 89 din 55gg 101118% 12 WU 24X14RA 14xU ._ 713 cfm 12' EFt-VTR SED7 LDRY 1OX6 80 cfm BTH2 FOY SRB 1 28 di 24x4 7' 24x4 176 cfm 10X8 BED2 EF1 - 50 CFM Fan EF2 - 60 CFM Fan EF3 s 110 CFM Fan EFL1 = 50 CFM Fan EF 2 - 80 CFM Fan EFL3 -110 CFM Fan VTR - Vent to Roof VTW m Vent to Wall DV - Dryer Vent RV - Range Vent - Lineset chase — .Condensate — - - =Thennostat 18f8 O SRB a Sman Reduction Box LRB - Large Reduction Box Fee - Feld Buill Box Job #: Lot 040 F1452 A RHG - W Performed by RINK for. Ryan Fbmes R. Pierce, FL 6' MBED 10X6 3 cfm J 61 cfm BX4 131 of MBTH 8X4 MWIC GARAGE AC PADS BY(3C1AN5� aorto' 36'SFPAMTKN 16'OFFWALL -PYCSEFRIGLINE CMhS S BYGC One Stop Cooling and Heating 7225 Sandscove Court Winter Park. FL 32792 Phone: (407) 829 - 6920 Fax: (407) 629 - 9307 www.OreSWpCoohrig.com EF1- VrR Scale: 1 : 98 Paget Rigls-& te8tUniversal2D18 18D.19 REU16262 MISJd-2716:1721 i Chano Permit # 18060664 Master Permit #"ll !, Owner Name: NVR INC Address: 2948 BE 3 ST (34/1)� Contractor. 06457 RYAN HOMES, NVR INC Fee Group _ Fee Desc Fee Amt Credit Peld Balance -_- DEPT COMMUNI AFFAIRS DEPT BUS/PROF REGULA JBLDG CODE JFL SURCHAR PUBLICART 12.13 18.19 1099.72 . 0.00 0.00 _ 0.0, 16.62 11.08 _ - 947.78 -4.49 7,11 151.94 1130.04 .0.00 975.48 154.66 BUILDING_ BUILDING BUILDING' BUILDING SFR SLAB NO ST' LANDSCAPE PLAN REVIE, _ 1077.96 60.00 75.00 150.00 0.00 0'.00 0.00 0.00 973.24 80.00 75.00 150.00 1D4.72 0.OD 6.00 0.00 1362.96 0.00 1258.24 104.72 CERT OCCUP RESD CERT OCC R - 50.001 0.001 mool 0.00 50.00 0.00 50.00 0.00 CODE COMP FEE ICC VALUE 132.001 O.Wj 114,001 18.00 132.00 0.00 114.00 18.00 IMPACTFEEADMIN- JIMPACTADM _ 204.511 0.00 • 17821 26.30 204.51..• .... 0.00 178.21 26.31 IMPACT FEE P $'R 1IMPACT PR; 1 5398.961 0.001 4704.58 694.40 6393.96 - - --0.00 4704.56 894:40 IMPACT FEE POLICE , IMPACT PIP 1 1169.36 .0.00 1018.96 150.40 1169.36 0.00 1018.96 150.40 IMPACT PUBLIC WORKS JIMPACT PW- _ 248.801 0.00 216-.801 32.00 248.80 0.00 216.80 L32.00 Total '9696.63. ' 0.00- 8516.25 1180.38