HomeMy WebLinkAboutFIELD - LAB REPORT/0(2 - a0 z Y
U1 r R S A L Date Typed: No.: Jan January 29, 201938
ENGINEERING SCIENCES FILE COPY
Consultants In: Geotechnical Engineering • Environmental Silences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Construction Materials Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
Client: Ryan Homes
1450 Centrepark Blvd Suite 340 sCAt'.A,
West Palm Beach, FL 33401 l,
s� 'y'v�
Project: Oakland Lake Subdivision Lot 40 `�Ci e9%'
5361 Oakland Lake Circle Permit tr8y 24XFt. Pierce, St. Lucie County, FL CCeA
As requested, Universal Engineering Sciences, Inc. (UES) representative(s) performed construction materials tes Ing and/or
field inspection services on the above project. Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package are summarized below:
Scope of Work
Work Order No. I Date I Type of Report
105833-1 1 01/17/2019 In -Place Density Test Report w/Activity Record
We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
Ila
JAN 3 0 2019
Permitting Department
St. Lucie County, FL
�6�•' 410ENgF •:qG
No. 48796
'•. -STATE of
li,s,ONAiitG�
Sincerely,
Universal Engineering Sciences, Inc.
Certificate of Authorization No. 00000549
frees'
Richard E.
Hoaglin, P.E.
2019.01.29
12:03:00
-05'00'
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
This item has been electronically signed and sealed by
Richard E. Hoaglin, P.E. using a Digital Signature. Printed
copies of this document are not considered signed and
sealed and the signature must be verified on any electronic
copies.
ICC Email: cbugg@nvdnc.com; rhager@nvrinc.com; sign/seal MAIL to ryan homes at 5369 Oakland Lake, Vero Beach, FL 32966
S
1 _t N V--- RSA' UES Report Noo: 1058331 ARC 011719
ENGINEERING SCIENCES On -Site Time(hrs):0.50
Consultants In: GeotechnicalEngineering , Environmental Sciences . Lab Time (hrs): 0.00
Geophysical Services @ Materials Testing • Threshold Inspection Travel Time (hrs): 0.25
Building Code Administration, Compliance Inspection & Plan Review Total Time (hrs): 0.75 ,
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 40
5361 Oakland Lake Circle Permit 1812-0024, Ft. Pierce, St. Lucie County, FL
Date of Activity: Thursday, 17 January, 2019
Technician: - Timothy Hughes
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the house pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for house
pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the
project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
The Contractor was notifiedof the test results or a copy was left for their records
.[BUN1%j__'__.1RSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
In -Place Density Test Report
L__ ?roject No: 0310.1700251.0038
LIES DOCS No:
LIES Report No: 105833-1 DT 011719
Clientt Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 40
5361 Oakland Lake Circle Permit 1812-0024, Ft. Pierce, St. Lucie County, FL
Area Tested: house pad
Type of Test: Field; ASTM D-6938 Nuclear Gauge Method Date of Test: 01/17/2019
Lab: ASTM D1557 Modified Proctor
Technician: Timothy Hughes
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlying soils below the tested depths.
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
SW corner of pad
0 to -1 ft
12.00
21143
114.6
5.2
100
A
2
SE corner of pad
0 to -1 ft
12.00
21143
109.3
4.1
95
A
3
NE corner of pad
0 to -1 ft
12.00
21143
112.3
4.8
98
A
4
NW corner of pad
0 to -1 ft
12.00
21143
114.5
5.1
100
A
(1) j Ref. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
21143
115.0
12.0
This test was performed without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
U,'VIAfEFSrL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
UES Project No.: 0310.1700251.0038
Date Typed: January 29, 2019
Construction Materials Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 40
5361 Oakland Lake Circle Permit 812-0.02 Ft. Pierce, St. Lucie County, FL
As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or
field inspection services on the above project. Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package are summarized below:
Scope of Work
Work Order No. Date Type of Report
105833-1 01/17/2019 In -Place Density Test Report w/Activity Record
vve nape inls Inrormatlon Is sutrlclent Tor your Immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
MAR 18 001[—RECEIVED:
cie county, Peing
Sincerely,
Universal Engineering Sciences, Inc.
Certificate of Authorization No. 00000549
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
ICC Email: cbugg@nvrinc.com; rhager@nvrinc.com; sign/seal MAIL to ryan homes at 5369 Oakland Lake, Vero Beach, FL 32966
ENGINEERING .SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing a Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
LIES Project No: 0310.1700261.0038
UES DOCS No:
UES Report No: 105833-1 ARC 011719
On -Site Time (hrs): 0.50
Lab Time (hrs): 0.00
Travel Time (hrs): 0.26
Total Time (hrs): 0.75
20 Brevard Avenue, Rockledge, FL 32965 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 40
5361 Oakland Lake Circle Permit 1812-0024, Ft. Pierce, St. Lucie County, FL
Date of Activity: Thursday, 17 January, 2019
Technician: Timothy Hughes
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the house pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for house
pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the
project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
UES Project No: 0310.1700251.0038
UES DOCS No:
UES Report No: 105833-1 DT 011719
In -Place Density Test Report
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 40
5361 Oakland Lake Circle Permit 1812-0024, Ft. Pierce, St. Lucie County, FL
Area Tested: house pad
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 01/17/2019
Lab: ASTM D1557 Modified Proctor
Technician: Timothy Hughes
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlvina soils below the tested depths.
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
SW corner of pad
0 to -1 ft
12.00
21143
114.6
5.2
100
A
2
SE corner of pad
0 to -1 ft
12.00
21143
109.3
4.1
95
A
3
NE corner of pad
0 to -1 ft
12.00
21143
112.3
4.8
98
A
4
NW corner of pad
0 to -1 ft
12.00
21143
114.5
5.1
100
A
(1) Ref. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
21143
115.0
12.0
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This test was performed without deviation from ASTM procedures.
This report shall not he reproduced, except in full, without the written approval of Universal Engineering Sciences.