GAS PIPING SCHEMATIC
BOARD OF COUNTY COMMISSIONERS GAS PIPING SCHEMATIC TANK SIZE: 50 d GALS. APPLICANCE — TYPE/SIZE Al C�cclerl�}v( A2 anK1ef� WIVV`L� A3 Tank Iw 5S; 4 -1LC� A4 �M Q A5 A6 BTU )44�oao BTU bQ BTU pG D BTU BTU PIPING LENGTH & SIZE Ll I FT. INCH DIA. L2 FT. 3/y INCH DIA. L3 4to FT. 3 cl INCH DIA. L4 I FT. WINCH DIA. L5 y 3 FT. 3)N INCH DIA. L6 I FT. 31�_INCH DIA. L7 FT. INCH DIA. L8 FT. INCH DIA. L9 FT. INCH DIA. L10 FT. INCH DIA. L11 FT. INCH DIA. L12 FT. INCH DIA. Revised 7/22114 PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FO OMPLIANCE REVIEWED BY DATE PLANS AND PERMIT PUB KEPT ON JOB OR NO INSPECTION WILL BE MADE,. If/1-1 06fs (PIPE SIZE WAS TAKEN FROM THE 2014 FBC FUEL GAS CODE - TABLE 402 u) aO (7 flora Jc.,T�u)' L e) C e- 64, oirZ FU-.1 Gcs ('Oj Table_ g0Ra' lC,ai) -t— Mo�u� e� Uc� S jau 12 Website: vmv stlucieco.cov 2300 Virginia Avenue - Fort Pierce, FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578 FILE COPY • IS SIZING TABLES I FOR • o Maximum Capacityof PE of UPressHour ed Drop of of 5 Petroleum C leum Gas with Pressure of 11h0 in. WC and aands a in. ' (based on a 1.52 specific gravity gas) ifiviii 1 I 187 125 99 84 74 67 56 50 45 41 38 95 33 29 26 1073 720 571 484 425 383 325 286 257 235 218 204 792 169 152 1391 934 740 627 551 497 421 370 333 305 283 264 249 219 197 1983 1331 1054 893 786 708 600 528 475 435 403 376 354. 311 280 3563 2391 1894 1605 1412 1272 1078 948 854 781 723 676 636 560 504 4724 3247 2608 2232 1978 1792 1534 1359 1232 1133 1054 989 934 828 750 10063 6755 5351 4535 3989 3592 3044 2678 2411 2207 2044 1910 1797 1581 1424 I I 11 1 II .11 11 .11 11 :11 •11 III 11 11 11 ,11 11 22 20 18 1b 13 12 68 11 63 10 58 9 54 9 51 8 48 8 46 8 44 7 42 7 40 129 167 113 147 102 132 86 112 76 99 89 81 75 70 66 63 60 57 54 52 238 209 188 160 140 126 116 107 100 94 89 85 81 78 75 427 376 338 287 252 227 208 192 180 169 160 152 146 140 134 642 569 516 441 391 354 326 303 286 269 265 244 233 224 216 1207 1061 956 810 712 642 587 544 508 478 453 431 411 394 379 2516BTUh=1CFH Maximum Capacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas with a Gas Pressure of 2.0 psi and a Pressure Drop of 1.0 psi (based on a 1.52 specific gravity gas) E�® 1 11 1966 1319 1045 886 779 702 595 523 471 431 399 373 351 309 278 11300 7586 6008 5092 4479 4033 3418 3007 2707 2478 2295 2144 2018 1775 1599 14652 9835 7790 6602 5807 6229 4432 3898 3510 3213 2975 2780 2617 2302 2073 20877 14014 11100 9408 8275 7451 6315 5555 5002 4578 4239 3962 3729 3280 2953 37574 25183 19946 16905 14869 13389 11348 9982 8988 8226 7618 7119 6700 5894 5307 43429 29848 23969 20515 18182 16474 14100 12496 11322 10417 9691 9092 8589 7612 6897 105963 71731 56339 47750 42000 37820 32054 28194 - 25388 23234 21517 20108 18926 16647 14990 I 11 1 11 ,11 11 .11 11 :11 •11 III II 11 11 •11 11 236 207 187 158 139 125 115 106 99 93 88 84 80 77 74 1355 1192 1073 910 800 720 659 611 571 537 508 484 462 443 425 1757 1545 1391 1179 1037 934 855 792 740 696 659 627 599 574 551 2503 2202 1983 1680 1478 1331 1218 1128 1054 992 939 893 853 818 786 4498 3956 3563 3019 2656 2391 2189 2027 1894 1783 1688 1605 1533 1469 1412 5903 5232 4740 4067 3596 3258 2997 2788 2616 2471 2347 2239 2144 2060 1'985 12705 11175 10063 8529 7502 6755 6182 5725 5360 5036 4767 4535 4331 4150 3988 25160TUh=1CFH Maximum Capacity of PE Plpe In Thousands of BTU per Hour of Liquefied Petroleum Gas with a Gas Pressure of 10.0 psi and a Pressure Drop of 1.0 psi (based on a 1.52 specific grov8y gas) 2476 1662 1316 1116 981 884 749 659 593 543 503 470 442 389 350 14234 9555 7568 6414 5642 6080 4306 3787 3410 3121 2890 2701 2542 2236 2014 18455 12388 9812 8316 7315 6587 5583 4910 4422 4047 3747 3502 3296 2899 2611 26296 17652 13981 11849 10423 9385 7954 6997 6300 5766 5340 4990 4697 4131 3720 47252 31720 25723 21293 18729 16865 14294 12572 11321 10361 9595 8967 8"0 7423 6685 53960 37087 29782 25489 22591 20469 17519 16527 14068 12943 12041 11297 10671 9458 8569 133476 89601 70967 60148 62905 47640 40376 35514 • - 31980 29267 27104 25329 23840 20970 18882 I I II � 11 ,11 11 .11 11 :11 '11 III 11 11 11 ,11 11 297 261 235 199 175 158 144 134 125 118 Ill 106 101 97 93 1707 1501 1352 1146 1008 907 830 769 719 676 640 609 582 557 536 2213 1946 1753 ' 1485 1306 1176 1077 997 932 877 830 790 754 723 695 3153 2773 2497 2116 1862 1676 1534 1421 1328 1250 1183 1125 1075 1030 990 5665 4983 4487 3803 3345 3012 2757 25M 2386 2246 2126 2022 1931 1861 1779 7334 6500 5890 6041 4468 4048 3724 3465 3251 3071 2916 2782 2664 2560 2466 unnn inm7 IOA]A imea oeeo Rsno 77R7 72f2 6739 6343 6005 5712 5455 5227 5024 2516BTUh=1 Ph: 1.800.662.0208 • Fax: 615.325.9407 = Web: www.gastite.com m M. r 'mow i. 1>•" �f"Y' � (t 7.e_{ ii �, .qY 1 v.-. �r2tcw 1=d mvP.r arvrwmxrwwvr.m.......m '..�-...........a..ra.me..rr�wa..,ma a. .� n...aP,.=•.rw.wa.'..ra...aavn...�.P... ...4+,.. � y wi r t n v r >� ,r .tw R-� r�J�2 - _ IwN+Perrueomr.wuemren..wp W r aw.a.W.WlnaM.am. als®wra.®moaaav�.rt'�mum r Vlum.auwaYwutW6Juaa�+Nem+�au'ena.0 vu wn w avvarvu wWK.w w .v .. w+MumtlPmNaAW v. lmaPemawHuauavwmmsa u .� w wbT mial'Mw.uP4Ya.AwnMNM.ee iTTw � _ Ir..il w.W.r.etlmA YAauWW arx P. Z cam+ - — Yx{a�v w '.w Fm le a7i w. a s �.ri I ryrys �r -..'gi+il wv a w.m.wN.w 'i .o...au sw"..rv. n..—w.r+r+.w-..om•.waro..wa i.: u�..we v.rarr3.v.e vy �a wv.a GAS PIPING INSTALLATIONS Ges Undiluted Propane Inlet Pressure 2.0 psi TABLE 402.4(27) si Pressure Drop 1.0 p SCHEDULE 40 METALLIC PIPE Specific Gravity 1.50 Pipe sizing between 2 pslg service and line pressure regulator. INTENDED USE PIPE SIZE (Inch) i 2 '!, '14 1 1!, 1! 211' 3 4 Nominal 2.469 3.068 4.026 1.980 1.610 2.067 Actuel lD 0.622 0.624 1.049 Capacity In Thousands of Btu per Hcur Length (ft) 2,680 5,590 I0.500 21,600 32,300 62,400 121'000 10 1,84D 1,480 1,260 1,120 3,850 3,090 2,640 2,340 2,120 7,240 5,820 4,980 4,410 4,000 14,900 11,900 10,200 9,060 8,210 22,300 17,900 • 15,300 13,600 12,300 42,900 34,500 29500 26,100 23,100 69,400 68,400 54,900 47,000 41,700 37,700 I2I,000 97,100 83,100 73,70D 66,700 247,000 247A00 198,000 I70,000 I50,000 136,000 20 30 40 50 60 11010 934 1.950 3,680 7,550 - 11,300 21,800 34,70D 6I,400 125,000 70 869 1,820 3,420 7,020 10,500 20,300 32,30D 57,100 116,000 80 815 1,700 3.210 6,59D 9,880 19,000 30.300 53,fi00 109,000 90 1,610 3,030 6.230 9,330 18,000 28,600 50,600 303,000 100 77p 1,430 2,690 5,520 8,270 15,900 25,400 44,00 91,00 125 682 1,290 2,440 5.000 7,490 14,400 23,000 40,700 82,900 150 618 1,19D 2,240 4,600 6,890 13,300 21,200 37,40D 76,300 175 569 529 1,110 2,080 4,280 6,410 12,300 19,700 34,800 71,000 200 469 981 1,850 3,790 5,680 10.900 17,400 30,800 62,900 250 425 889 1,670 3,440 5,150 9,920 15,800 27,900 57,000 300 391 817 1,540 3,160 4.740 9,120 14,500 25.700 52.400 350 364 760 1,430 2,940 4,410 8,490 13,500 23,900 48,800 400 341 714 1,340 2,760 4.130 1,960 12,700 22,400 45,800 Ott 322 674 1,270 2,610 3,910 7,520 12,000 21,200 43,200 500 306 640 1,210 2,480 3,710 7,140 I1,400 20,100 41,100 550 292 611 1,150 2,360 3,540 6,820 10,900 19,200 39,200 600 280 585 1.100 2,260 3,390 6,530 10,40D 18,400 37,500 650 269 562 I,O60 2,170 3,260 6,270 9,990 17,700 36,000 700 259 541 1,020 2,090 3,140 6,040 9,630 17,000 34,700 750 250 523 985 2.020 3,030 5,830 9,300 16,400 33,500 800 242 Sun 953 I,960 2,930 S,fi40 9,000 15,90D 3?,400 950 900 235 490 924 11900 2,840 5,470 8,720 15,400 31,500 950 228 476 897 1,840 2,760 5,310 8,470 15,000 30,500 1,000 222 463 973 1,790 2.680 5,170 8,240 14,600 29,700 1,100 210 440 829 1.700 2550 4,910 7,830 13,800 28,200 1.200 201 420 791 1,620 2,430 4,680 7,470 . 13,200 26,900 1,300 192 402 757 1550 2,330 4,490 7,150 12,600 25,800 1,400 185 386 727 1,490 2,240 4,3I0 6,870 12,IOD 24,800 1,500 178 372 701 1,440 2,160 4,150 6,620 11,700 23,900 1,600 172 359 677 1.390 2,080 4,010 6,390 11,300 23.000 1.700 166 348 655 1,340 2,010 3,890 6,180 10.900 22,300 1,800 161 337 635 1,300 1,950 3,760 6,000 10,600 21,600 1,900 157 327 617 1,270 1,900 3,650 5.820 10.300 21,000 2,000 1 152 1 319 600 1,230 1 1,840 1 3,550 I 5,660 10,000 20.400 For SI: 1 inch = 25A mm, 1 foot = 304.8 tam, I pound per square inch = 6.895 kFa, i-mcn water commn = 0.2489 kFu, 1 British thermal unit per hour = 0.2931 W. I cubic foot per hour = 0.0283 m'!h, I degree = 0.01745 rod. Note: All table entries have been rounded to three significant digits. 52 FLORIDA BUILDING CODE - FUEL GAS, 6th EDITION (2017)