Loading...
HomeMy WebLinkAboutLOAD CALCULATIONSF7Optional Load Calculation Heat Larger Than Air a3co SF x 3VA Living Only (2) Small appliance ckts @ 1500VA each Refrigerator @ 1500 Refrigerator @ 1500 Freezer @ 150D Washing Machine @ 1500 Dishwasher @ 150o Disposal @ 1500 Mini Sewer @ 1S00 Clothes Dryer @ 5000 Range @ 12000 Water heater @ 4500 RECEIVED Fixed microwave @ 150o Vacuum @ 1500 • NOV 3 0 9,018 Trash Compactor @ 1500 Pool Heater @'name plate' . ST_Lucie County, Permitting Spa @ 'name plate' Motors 746VA per HP Garage Door Opener )( a 1) Total 2) First 10 KVA of general load @ 100% 3) Subtract line 2 from 1 4) Multiply line 3 @ 40% 5) Add lines 2 and 4 6) 60/50amp breaker for heat (10000) 7) 40/30amp breaker for heat (5000) 8) Total heat -Add lines 6 and 7 9) Multiply line 8 @ 65% 10) Add lines 5 and 9 11) Divide line 10 by 240 71s mmary: Lintotal KWLine total Amps ejgo0 3000 1500 ISOp 15v � 15o G GoA� 51�l�1� .oAb5 trD __ Idy OUO • SCBy�E® St Lucie County (Generator Size Needed) (Breaker Size Needed)