HomeMy WebLinkAboutCERTIFICATION LETTERNovember 12, 2018
RE:
ProjeclfJob # 349045
Project Address:
AHJ
SC Office
Design Criteria:
CERTIFICATION LETTER
Gallardo Residence
8550 Belfry PI
Port St. Lucie, FL 34986
St. Lucie County
Orlando
- Applicable Codes = 2017 Florida Building Code (6lh Edition) / IEBC, ASCE 7-10, and 2015 NDS
- Risk Category = II
- Wind Speed = 160 mph, Exposure Category C, Partially/Fully Enclosed Method
- Ground/Roof Snow Load = 0 psf
- MP1: Roof DL = 14 psf, Roof LL = 18 psf
Version #74.1 -1
SCANNED
BY
St Lucie County
Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.06974 < 0.4g and Seismic Design Category (SDC) = A < D
To Whom It May Concern,
A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Testa.
Structural evaluation was based on site observations and the design criteria listed above.
Based on this evaluation, I certify that the alteration to the existing structure by installation of the PV system meets the requirements of the
applicable existing building and/or new building provisions adopted/referenced above.
Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the
manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading.
The PV assembly hardware specifications are contained in the plans/dots submitted for approval.
Tesla, Inc.
T 5 •b n 3055 Cleampw Way, San Mateo, CA 94402
p 650 63B 1028 ( 650 658 1029
1
Version #74.1 -1
HARDWARE. DESIGN AND STRUCTURAL ANALYSIS RESULTS;SUMMARY'TABLES
Landscape
Hardware.
Hardware -'Landscape�Modules'StandoffSpecifications.� - -
X-XSpacing
X-X Cantilever
Y+Y Spacing)
Y-Y Cantilever
Configuration
i Uplift DCR
MP1
48"
2T
39"
24"
Not -Staggered
70.1%
Portrait-
t Hardware:-Portrait,ModuleWStandoffrSpecifications
.
I X-X Spacing)
X-X Cantilever'
i Y-Y Spacing
_ -Y-Y Cantilever
I Configuration
Uplift.DCR
MPi
24"
16"
52"
24"
Not -Staggered
46.7%
MHardware
Mount ng Planes'
;Roof Pitch' - _ ._
- Clualificatiou�Resulta
(Degrees).
Member Evaluation Results
M131
27'
Member Impact Check OK
Tesla, Inc.
T a 5 L- li i 3055 Clear iew Way, San Mateo CA 94402