HomeMy WebLinkAboutPOWER WALL PLANSABBREVIATIONS ELECTRICAL NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET —BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE P01 POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT LICENSE MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: St. Lucie County UTILITY. Florida Power and Light CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESTA INC., NOR SHALL IT BE DISCLOSED IN MOLE OR IN PART TO OTHERS OUTSIDE THE RECINENYS ORGANIZATION, EXCEPT IN CONNECTION KITH THE SALE AND USE OF THE RESPECTIVE TESTA EQUIPMENT, VATHOUT THE WTTEN PERMISSION OF TESTA INC. 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER —CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY —RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE NTH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WALL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH THE 2017 FLORIDA BUILDING CODE (6TH EDITION), FLORIDA ARE PREVENTION CODE (6TH EDITION). 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. nwmem JB-349045 00 MOUNTING SYSU ZEP Miqhty Hook JURISDICTION NOTES JACKIE GALLARDO 8550 BELFRY PL PORT ST. LUCIE, FL 34986 ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE DATE:/ 2 /9-/ V PLUMB: DATE: MECH: DATE: VICINITY MAP 11.7 KW PV ARRAY 27 KWH ENERGY STORAGE SYSTEM PACE Nr/E INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL NEWS Sheet 4 UPLIFT CALCULATIONS Sheet 5 THREE LINE DIAGRAM Cutsheets Attached SCANNE® BY St Lucie County REV BY DATE COMMENTS REV A 3B 10/31/18 layout Charge/Added 2 PW s + s + r Frida Arroyo I T= 5 L n a 10/31/2018 PITCH: 27 ARRAY PITCH:27 MPl AZIMUTH:237 ARRAY AZIMUTH:237 MATERIAL: SDanlsh Tile STORY: 1 Si No 81150 -0'. ; 2 9 STATE OF LEGEND 0 (E) UTILITY METER & WARNING LABEL O INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS ® p AUTOMATIC RELAY p DC DISCONNECT & WARNING LABELS u7i JE��31 AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS O ENERGY STORAGE SYSTEM FOR STAND ALONE OPERATION QQ DISTRIBUTION PANEL & LABELS Q LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER Q RAPID SHUTDOWN 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED r, _-I n `I INTERIOR EQUIPMENT IS DASHED L :�J SITE PLAN w N Scale:1/16" = 1' 01, 16' 32' F CONFIDENTIAL - THE INFORNATION HEREIN CONTAINED SHALL NOT BE USED FOR THE TESLA NOR of ANYWDISMO JOB NUMBER: JB-349045 00 �'°"" 'M JACKIE GALLARDO 11.7 KW PV ARRAY Frida Arroyo T 5 L n SHALLBENEFI ED IN R IN SHALL IT BE DISCLOSED E OR Nou"°"e'�sIEEE ZEP Mi ht Hook 8550 BELFRY PL 27 KWH ENERGY STORAGE SYSTEM PART TO OTTERS OUTSIDE HE RECIPIEECTIONNYS N PORT ST. LUCIE, FL 34986 IaaAEs: (36) SolarCity Standard SC325 ORGAHZATION, EXCEPT IN CONNECTION qTH EPTIN ON THE SALE AND USE OF THE RESPECTIVE PACE NNE SHEET: REY. DATE INVORNR Delta I Solivio 5.2 TL TESLA EQUIPMENT. NnHOUT THE NTETTEN PQMASsON OF TEsLA "o SITE PLAN 2 a 10/31/201B S1 (N) PV MODULE (E) MOUNTING PLANE (MP) SV TYPICAL PV SIDE VIEW NTS ZEP SPANNER BAR (6) (1) DIA BOLT & NUT (1) (2) (Z) (3) ZEP SPANNER BAR CLAMP 3, STANDOFF (E) TILE u V u u (E) ROOF DECKING (5) (4) 5/16- DIA STAINLESS STEEL LAG BOLT 5' (2-1/2• EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES (E) RAFTER STANDOFF SScale: 1 1/2" = 1' ( INSTALLATION ORDER LOCATE RAFTER, MARK RAFTER LOCATION, AND REMOVE TILE. PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER CLEAN PAPER AROUND PILOT HOLE. ADJUST STANDOFF TO BATTEN HEIGHT. SEAL PILOT HOLES AND BOTTOM OF STANDOFF WITH POLYURETHAN SEALANT, LAG STANDOFF INTO RAFTER. NOTCH TILE WEATHERING TO FIT AROUND STANDOFF. REINSTALL TILE. No 81150 crz 9 • STATE OF 141 '�� 0 R 1 P' G�c�4Q: STANDOFF DETAIL ONLY CONFIDENTIAL - THEIFORMATIONHEREIN CONTAINED SHALL NOT BE USED FOR THE BOUT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION VATH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WTHWT 7ME MRITTEN PERMISSION OF TESLA INc. JOBNUMffk JB-349045 00 11.7 KW PV ARRAY 8550 BELFRY PL 27 KWH ENERGY STORAGE SYSTEM PORT ST. LUCIE, FL 34986 PAM NNE STRUCTURAL VIEWS Frida Arroyo T — 5 L n MMM S,,,E,I ZEP Mighty Hook MCDMM. (36) SolorCity Standard SC325 SHEET: my.. DATE 3 a 10/31/2018 NVaDEk Delta # Solivia 5.2 TL CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED N Nia.E OR IN PART 70 OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION. EXCEPT N CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE MRITTEN PERMISSION OF TESLA INC. M NUME101 JB-349045 00 YDIMTM STSIEIL ZEP Mighty Hook Standard SC325 JACKIE GALLARDO 8550 BELFRY PL PORT ST. LUCIE, FL 34986 10.31.20f 0 Version 1174.1 DESIGN SUMMARY Job#349045 Jobsite Specific Ut pg De61 n Cd*rls Design Code trportanoe Factor Utimate Wind Speed Elposrae Category Grand Snow Load ASCE 7-10 1.0 160 nph C Fig_ 1609A SeAm 26.7 ASCE Table 7-1 MPSpecific Design Information MP Name MP1 0 a Roofing Spmish Tile Rool — _ _ ..- — 5lantloR W11A%Noce HaG ST Pik 47' SIJRI L PY SIIFILL' Non4'V Ito Pat-- - Standoff Spacing and La out MP Name 11I1o1 X-spwing 48' X-Candlever 2V 3 Y-spacft 311. Y-cwdMvver 24• x-stancirig 24- CXCanelever 00 16" Y• SZ a. YCandlever 24" LayoutNat- XaidYwernmdnemsthgme&ma"mk&mtotheswum"thasupponsthePV Xis across rafters and Y n rafters 11.7 KW PV ARRAY 27 KWH ENERGY STORAGE SYSTEM PAM NNE: DESEN: Frida Arroyo SIEET: REV. 4 a T=SLn GROUNDMAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) /B GEC TO (E) GROUND ROD Panel Number:00040UF Inv 1: DC Ungrounded -(I )Delta / sdirio 52 n LABEL a -(36)SdarCity Standard SC325 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number. ACp7878 Inv 2: DC Ungrounded Inverter,52ODK 24OV, 97.5x, DO", PLC PV Module; 325W, 306.5 PIC, 40MM, Wht Backsheet, MC4, 600v, ZEP St a 2, 96-C JINV Underground Service Entrance Tie -In: Supply Side Connection -(I)Detta / Sorm 52 TL LABEL B Inverter, 52001W, 24OV, 97.5x, Zigbee. PLC Voc: 69.6 Vpmax: 57.6 Ise AND ImpARE SHOWN IN THE DC STRINGS IDENTIFlER E 200A MAIN SERVICE PANEL Delta E 20OA/2P MAIN CIRCUIT BREAKER (N) 125A EATON Inverter 1 IND 320018 (E) NIRING LOAD CENTER ❑A 7 ❑B L Y 3 DC- Soli ad5.2 TL MP 1; lx6- 25A 2P 3DA 2P L1 emv r------------ _____----__ ________-- ---_-� EGC - _ - - s 2 N 6 --- *M�111.1, N G --------------------------- Oc. MP1:2x6 E --- ---------------------------------------------- Gc A 2(I)ConduR K1t 3/4• EMT Delta Inverter 2 IND 32.0018 A ❑ ❑e 10 3 -- ! -------------------------� 1 Delta DC. A 2P Solivio 5.2 TL DC- MP 1: 1x6 zoozP i Ll ENERGY X zavr----------- ----------- Ecc -----------------------------� B aDe TO 120/240V ; SINGLE PHASE N STORAGE _ _z SYSTEM i I L2 N i g r--- UTILITY SERVICE �i i ' A2----------- -mac -- oC• MP 1: 2x6 (E) LOADS i i ENERGY X ___________- _____ __ __________________a ' ; I N STORAGE I L - _ _ _ - _ _ _ H3C SYSTEM (I )Cmhdult Ktt; 3/4' EMT 1 (E) 200A Main Service Panel Voc* = MAX VOC AT MIN TEMP 1 )Yeah 1118431-OD-K BACK-UP GATEWAY; for ACPW20. ASY, NA with 3G r/ Antenna, PM2.0, 1acA SCCR (2)Teda !/ 1108567-00-E-ST ^ AC PDWERWALL 5.BkVA; Home Energy Storage,13.5KXH, Stockoble, PW2�iC p B (6)Delta Salida SmrtRSSRpdShtdn,Upol 2018 /� A (2)YUL71-CONTACT PV-AZB4 320018; Branch Socket; MC4 U-Jont Connecter, Female DC -(1)Simnens/ EOB695 'K2pp� Circuit Brecker MBK 2DOA/2P, 22kAIC Y (4)CUTLER-H I BR23D Bredmr, 30A 2 Spam -(2)M3ZOO1 MULTI -CONTACT PVlug; M 320019; Branch Plug; MC4 U-Joint Connector. Made , -(1)CUIIER-H125 BR2125 &esker, 125A�2�, 2 Spaces _(I) (� (4)AWG j10, PV Wine. BOOV, Block (1)AWG p0, THWN-2, Green EGG Voc* =M3.7 VDC Ise =12.06 ADC Vmp =345.6 VDC Imp=11.3 ADC L ON CBR12241T5AR, 120/240V, NEMA 3R (1)ConduH Kit 3/4' EMT . , .. _ _ .... . C7-(2))AWG fill. PV Wire, 6DOV, Blade (I)AWG 110, THWN-2 Green EGG Voc* =443.7 VDC Ise =12.06 ADC Vmp =345.6 VDC Imp=11.3 ADC (1 Cond dN Kit. 3/4' EMT ............ ....... ... ................. frT� AWG /2 0, THWN-2, Block (1)AWG J6, THWN-2, Green EOC L (1)Capdull IT (1)AWG /10. THWN-2, Black ®�(I)AWG 010, THWN-2, Red Vmp O (1)AWG N0. THXN-Z Green EGG (1 Condutt oc = _ Vmp =345.6 VDC Imp=5.65 ADC 2 AWG /10, PV Win% 600V, Block O (1)AWG p0, THW-2 Green EGC Voc* = 443.7 VDC Isc = 6.03 ADC VmP =345.6 VDC Imp=5.65 ADC , 2 PVC, Schedule 80 [� (1)ANG i1, 7HNN-2 Red (1)AWG #10, THWN-2. White )) ......-(1 AYIG �,. 1HWN-T. Green (1)AWG #10, THWN-2, Black NEUTRAL =240 VAC Imp=21.6 AAC EGC/GEC.-(i)Canddl KIt.3/Y EIIT, .. ...... , , ...... ®R51-(I)AWG KH; 3/4', FLIT ..................................... G (4 ANC 0. PV Wre, BOON, Blank [�� r N0. THWN-2, Green EGG Voc* -443.7 VDC Lsc =12.06 ADC Vmp 345.6 VDC Imp=11.3 ADC O (1 Candutt Kit; 3/4' EMT )) - - (4)AWG /10. PV Wlre, 60OV, Black (1)AWG /10, 1HWN-2 Green EGC .. . Vac` =443.7 VDC Ise 6.03 ADC Vmp 345.6 VDC Imp=5.65 ADC l� (I)AWG /I. THWN-2 Black 1 AMG 0 THWN-2, Red ®�(I)AWG _ (1))Condult Kit 3/4' EMT ..... ......... (1 CanduN Kit 3/4' EMT Con `-' (1)AWG /l, THWN-2 White NEUTRAL-0)CopduR. -(1)ANC 46, 1HNN-2, Grown EGG2 PVC, Schedule 80 i10, THWN-2, White -((1))ANG TH.NN-2, Grown NEUTRAL Vmp =240 VAC Imp=21.6 AAC EGC/GEC-{1)CandhW. K8:. 3/4'EYT,, ..... O (2)AWG /l0. PV Wke, 60OV, Block (1)AWG po, 7HNN-2. Green ECC ... Voc* =443.7 VDC Isc =12.06 ADC Vmp =345.6 VDC Imp=11.3 ADC 3 Or61 (2 /l0. PV Vhe, BOON. Black i10, THWN-2 Green EGC ...Voc* =443.7 VDC Ise ...03 ADC Vmp =345.6 VDC Imp=5.65 ADC .........(t)AW0 F0. THWN-2, Block __.. ...... _ . (I )Codult Kit 3/4' EMT . ................................... (1)AWG I))Candult Kit 3/1' F1IT OR /0, HWN-2, Red (I)AWG #10, THWN-2. While NEUTRAL -(1 )CQ(lDUn KIT ®�}(1)AWG G� (23AYG rQ PV Ytra, BOON, Block* /10. IHWN-2, Green EGC Voc* =4437 VDC Ise =6.03 ADC Vmp =345.6 VDC Imp=5.65 ADC ...... r'� (4)AWG 00, PV Wire. 60OV, Black ®Fru�-(i)AWG THWN-2 Green EGG Voc* =443.7 VDC Ise =6.D3 ADC Vmp -345.6 VDC Imp=5.65 ADC - 1 ANG 0 THWN-2 Green 1 x 10' EYE Goodall: t3 1 Conduit Kit; 3/4" EMT /10. �l CONFIDENTIALS - THE HEREIN JDB ND16EIt JB-349045 00 GDSTOWIR OESCYPTKN: DEM T BE USED CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JACQUELYNN GALLARDO 11.7 KW PV ARRAY Frida Arroyo T 5 L WNW SWSEIk SiAL IT BE DISCLOSED IN WHOLE OR IN ZEP Mi nt Hook 8550 BELFRY PL 27 KWH ENERGY STORAGE SYSTEM n PART TO OTHERS OUTSIDE THE RECIRENY5 PORT ST. LUCIE, FL 34986 MODM' ORGANIZATION, EXCEPT IN CONNECIION WITH THE SALE AND USE OF THE RESPECTIVE (36) SolarCity Standard SC325 SM: REV. DATE TESLA EOUPMENT, WITHOUT THE WRITTEN PATE KA1E PERMISSION of TESL" INC.Delto I Solivia 5.2 TL THREE LINE DIAGRAM 5 a 10/31/2018 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 8550 Belfry PI INVERTER AND DC DISCONNECT INVERTER AND DC DISCONNECT UTILITY SERVICE Battery storage utilized at this facility SOLAR PHOTOVOLTAIC ARRAYS) PHOTOVOLTAIC BACK —FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-349045-00 CONFlDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE .Derammr JB-349045 00 JACKIE GALLARDO 11.7 KW PV ARRAY Frido ArroyoBENEF T 5 L AIDIEP fight zEP Mighty Hook INC., NOR SHALL IT BE DISCLOSED IN YATOIE OR IN SHALL I OF INTONE EXCEPT MOLE 8550 BELFRY PL 27 KWH ENERGY STORAGE SYSTEM n PART TO OTHERS OUTSIDE THE RECIPIENTS PORT ST. LUCIE, FL 34986 ORGANIZATION. EXCEPT IN CONNECTION MATH THE SALE AND USE OF THE RESPECTIVE (36) SolarCity Standard SC325 PACE NNE SHEET: REM. DATE INVERTER: N1flt1�. # Solivia 5.2 TL TESLA EQUIPMENT, MATHOUT THE WRITTEN PERIAIs9oN of TESLA INC. SITE PLAN PLACARD 6 a 10/31/2018 NARNING:?HOTOVOLTA!CPOWERSOURCE Ij •`'11`' WARNING Code:Per NEC . ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS Label • • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC DC LOAD SIDES MAY BE ENERGIZED DISCONNECT IN THE OPEN POSITION •'' - • - • - . PHOTOVOLTAIC POINT OF MAXIMUM POWER- INTERCONNECTION , POINT CURRENT (Imp) WARNING: ELECTRIC SHOCK MAXIMUM POWER -=HAZARD. MAXIMUM POWER- • • - DO NOT TOUCH POINT VOLTAGE � �. TERMINALS. TERMINALS ON MAXIMUM SYSTEM BOTH THE LINE AND LOAD SIDE VOLTAGE (Voc)_ MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT A CURRENT POSITION. FOR SERVICE DE -ENERGIZE BOTH SOURCE (Isc) AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT MAXIMUM AC . - • • OPERATING VOLTAGE V WARNING ' ELECTRIC SHOCK HAZARD ..- IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE CAUTION UNGROUNDED AND ENERGIZED DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING ' ELECTRICAL SHOCK HAZARD ' DO NOT TOUCH TERMINALS CAUTION TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFED DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT WARNING INVERTER OUTPUT "'" • • CONNECTION PHOTOVOLTAIC AC DO NOT RELOCATE DISCONNECT THISO DEVICE MAXIMUM AC A OPERATING CURRENT MAXIMUM AC OPERATING VOLTAGE WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDEDAND MAY BE ENERGIZED LabelLocation: BACKUP LOAD CENTER CAUTION Code:Per TRI POWER SOURCE Per ••- NEC 408.4 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 0 D THIRD SOURCE IS ENERGY STORAGE SYSTEM Label• - CAUTION DO NOT ADD NEW LOADSPer Code: NEC ' WARNING Per ..- THIS EQUIPMENT FED BYNEC 705.12.D.2.3.c Label • - . MULTIPLE SOURCES. TOTAL CAUTION �DEV CES EXCOLUDINGUMA NNT THIS PANEL HAS SPLICED FEED- Per • •' SUPPLY OVERCURRENT DEVICE, THROUGH CONDUCTORS. SHALL NOT EXCEED AMPACITY LOCATION OF DISCONNECT AT ENERGY OF BUSBAR. STORAGE BACKUP LOAD PANEL Label Location: DUAL POWER SOURCEPer Code: SECOND SOURCE ISNEC 705.12.D.3 ENERGY STORAGE SYSTEM Label• - ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHTPer Code: r- ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALLPer Code: •- • - ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALL Per Code: Label• - ENERGY STORAGE SYSTEM ON SITE LOCATED INSIDEPer Code: Disconnect (BLC): Ba• Load Center '.•.SDIarCity I ©pSoiar Next -Level PV Mounting Technology •'^•SolarClty I Z pSolar Next -Level PV Mounting Technology .ZS Span for concrete the roofs Components 1x 3x U Spanner Bar Part Nos, 850-1400-4x 501399 - 3x 850-1398 - Is OA � lirrsnssV Tart \ - Splice Kit Spanner Clamp Part No. 850-1401 Part No. 850-1194 wcall,t Listed to UL 2703 Listed to UL 2703 r+i MwrnMlrwt reMVq jq tiW e� Description + • % PV mounting solution for concrete the roofsl • Works with all Zap Compatible Modules N°abrx0° Auto bonding UL-listed hardware creates structural and electrical bond • Zap System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or 'Type 2" Mighty Hook V2, HDG Interlock Cam Foot UL LISTED Specifications Part No. 850-1461 Part No, 650-1388 Part No. 850-1413 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 n• Designed for pitch roofs Installs in portrait and landscape orientations Zap System supports modulewind uplift and snow load pressures to 50 cast per UL 1703 • Wind tunnel report to ASCE SCE 7 7-OS and 7-10 standards • Zap System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zap System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" Ak 146kb • Zap wire management products listed to UL 1565 for wire positioning devices *104 • Attachment method UL listed to UL 2582 for Wind Driven Rain Ground Zap Array Skirt, Grip, End Caps DC Wire Clip Part No. 850-1172 Part Nos. 850-0113, 850-1421, Part No. 850-1448 ETL listed to UL 467 850-1460, 850-1467 Listed to UL 1565 zepsolar.com zepsolar.com Listed to UL 1565 This docunrent does not create any express warranty by Zap soar or about its protluds or services. Zap sister's sole warranty is contained in he venttsn product warainty for mis dowmenl does not create any express warrarny by zap solar or about its produ or semoes. Zep Saar a sod, vverenh is mntainetl in he wriaen podia ordinary for as& product The end.ueer domanantslion shipped wiec Zap Sdai's products wintitules the sole specifications referred to in the product wananty The customer is solely each product. The end -user documentation shipped w8h Zep Solar's products constA tes the we spedficetions referred to in he product warranty. The Messmer is solely responade for vaMying Me sutaGky d ZepSofara products for each use. Speti at ons are wbjed to rnar ge without mhos. Patents and Apps. zspats.rnm. responsible for venting he witawhy, of Z8pS01ars products for each use. Speoposmons are sublacl to ctlange wiMoul notice. Patents arm Apps: zspms cam. Documenttl80d1730.001 Rev A Date fast exported: April 20. 20152:14 PM Document a 110i 736001 Rev A Date last mpori April 20, W152:14 PM 0 d g saw0ty to I o4`/ e_a w • Solar Inverters Transformerless (TL): 3.8 kW, 5.2 kW, 6.6 kW, 7.6 kW Wide Operating Voltage Range: 85 - 550V Wide Operating Temperature Range: -13 - 158°F (-25 - 70°C) High CEC Efficiency. 97.5% Integrated AFCI (Arc Fault Circuit Interruption) NEMA 4X plus Salt Mist Corrosion Protection Natural Convection Cooling Dual MPPT (5.2kW / 6.6kW / T&W) Compact and Lightweight UL 1741 / IEEE 1547 / IEEE 1547.1 / CEC �. Listed /UL 1699B(Type 1) / NEC 690.11 a us Delta Solar Inverters Datasheet for SolarCity ego v 360 v 85-550v 200 - 500 V 180A 200A 20.0 A per MPP Backer 250 A per MPP VaNxr - 42M W 50W W 5600 W 1.5 InNmal 1 2 2 4 3000 W Mi W 5200 W SIM W 7800 W 3000 W 0 208 V 1 M) W C 2W V 1 5W) W C 20B V I 6600 W@ 208 V 1 6600 W 0 200 V/ 3000 W a 240 V MOW @ 240 V 5200 W® 240 V B60D W Q 24a V TWO W Q 240 V 183-220 V 02W V 1211-264V Q240V 14.4 AC 208 V1 158A 0208 V1 24 0A®2W V1 317A0200V/ 317 A0208 V1 12.5 A0240V 15.8 A0240V 216 A®240V 27.5 A0240V 317 A®240V 6O Hz 69.3-W5 Hz _ 57.0-W0H: �1.sW c3% >009 0.851- 0.05c <500b(A)®Im 98% 9) $%®20W I9] 5%0240V -13 -1W-F (-25 7WC) I canting above 122-F (W-C) �0 -185-F (40 - 05.0) 0-1W9, 2000m above see bvel 19.5 x 15,8 x 8.5 in(495 x401 x 216 mm) 26.8 x 158 x 85 in (M x 401 x 216 Pan) 43,0IM (19.5 kg) 65.0 be (29.5 kg) Natural Convection SprNg brmnals in cpnmcdon box AWD 12 -AM 6 Copper (AccacNg b NEC 310.15) 2 Paks of ep0ng bmanek in connection box 4 pus 01 sprnp temgnals in connection box AWG 12 -AAG 6 Copper (Acnonli g to NEC WS ) baSee 3 LEDs, 4Line LCD Dwc,an Akanklum STANDARDS/DIRECTIVES WARRANTY DaeaP tata Corponion. Inc. 49101 Friona BNd, FrmpiL CA 9rSY SNc Emal immmealrsiNetaawcan Suppod Small Imade, supportededaew.can Sets HMkia 477�051 a •18263894b21 S�glvd Hplkm'.•14InJ ,IW Supp is md.I:.,f1&36&00,9 MOMm In Fnda/ Imm 7 amb 5 Pan PST (apal kom HOWeye) NEMA 4X IEC 600 24I Sag mat UL 1741 Sei Eckoq CSA C223 140.107.1-01 UL 1996 NEC 6W M UL 1741 CRD IEEE 1UT IEEE 1547A FCC on 15 Canis B UL 16998 (Type 1), NEC 6W 11 UL 1741 CRD PVRSS, NEC 6W,12 Nab SMART RSS) ANSI C121 1.1 % Acalrecy) California Rub 21, HECO Compliant, IEEEISQ 10 years e AELTA POWERWALL Testa Powerwall is a fully -integrated AC battery system for residential or light commercial use. Its rechargeable lithium -ion battery pack provides energy storage for solar self -consumption, time -based control, and backup. Powerwall's electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market -leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 120240 V Feed -In Type Split Phase Grid Frequency 60 Hz Total Energy' 14 kWh Usable Energy' 13.5 kWh Real Power, max continuous° 5 kW (charge and discharge) Real Power, peak (10s, off-gdd/backupf 7 kW (charge and discharge) Apparent Power, map, continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10s, off -grid backup) 72 kVA (charge and discharge) Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split -Phase Loads 100% Power Factor Output Range +/-1.0 adjustable Power Factor Range (full -rated power) a/- 0.65 Intemal Battery DC Voltage 50 V Round Trip Efficiency' 90% warranty 10 years 'Values provided for 25-C (77-F), 3.3 kW chargeldscharge power. 'In Backup mode, ghd charge povar is Ilmited to 1.67 kW. eAC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642. UL 1741. UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) T=SLFi MECHANICAL SPECIFICATIONS Dimensions 1150 mm x 755 mm x 155 mm (45.3 in x 29.7 in x 6.1 In) Weight 125 kg (276 6s) Mounting options Floor or wall mount 755mm 156. 129] Inl far MI T9BLi+ 1150 rem (45.3 in) ENVIRONMENTAL SPECIFICATIONS Operating Temperature -20'C to SWC (-4'F to 122-F) Optimum Temperature (rC to 30-C (32-F to 86°F) Operating Humidity (RH) Up to 100%, condensing Storage Conditions -20-C to 30-C (-4°F to 86-F) Up to 95% RH, non -condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m ISM ft) Environment Indoor and outdoor rated Enclosure Type NEMA3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (wiring Compartment) Wet Location Rating yes Noise Level ® 1 m < 40 dBA at 30-C (86-F) TESLACOM/ENERGY POWERWALL Backup Gateway The Backup Gateway for Testa Powerwall provides energy management and monitoring for solar self -consumption, time -based control, and backup. The Backup Gateway controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a circuit breaker, the Backup Gateway can be installed at the service entrance. The Backup Gateway communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Testa app. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 230 V, 120240 V Feed -In Type Single & Split Phase Grid Frequency 50 and 60 Hz Disconnect Current 200A Maximum Input Short Circuit Current 10 kA Overcommit Protection Device 100-200 A: Service Entrance Rated Overvoltage Category Category IV AC Meter Revenue grade (+/-1 %) Connectivity Ethernet, Cellular (3Gy, WI-FI Leer Interface Testa App Operating Modes Support for solar self -consumption, time -based control, and backup Backup Operation Automatic disconnect for seamless backup transition Modularity Supports up to 10 AC -coupled Powerwalls Warranty 10 years ' Circuit Meaker requr d for installation at service entrance. 2 Cellular connativity sublect to network operator serve coverage and &gnat strength. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, IEC 62109-1 CSA C222.107.1 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003. IEC 61000-6-3, EN 55024, EN 301489-1. EN 301489-7, EN 301489-17 Environmental RpHS Directive 2011/65/EU, WEEE Directive 2012/19/ Battery Directive 20f16/66(EC REACH Regulation Seismic Act56, IEEE 693-2005 (high) rll�sy.r_ MECHANICAL SPECIFICATIONS Dimensions 740 mm x 378 mm x 129 mm (29.1 In x 14.9 in x 5.1 in) Weight 16.4 kg (36 lbs) Mounting options Wall mount 378 mm (14.9 in) 740 mm (29.1 in) 129 mm (5.1 in) ENVIRONMENTAL SPECIFICATIONS Operating Temperature -2G'C to 50-C (-4°F to 122-F) Operating Humidity (RH) Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA3R Ingress Rating IP44 TESLACOM/ENERGY SC -SERIES MODULE MORE POWER, FEWER MODULES With a sunlight to electricity conversion efficiency of over 19.4%, the module ranks amongst the highest in the industry. That means our modules can harvest more energy from the sun, which means it takes fewer of our modules to power your home. Plus, they generate more power output during the hottest times of the day, even in warmer climates. SC325 AND SC320 MODULE Zap Compatible 96-Cell PV Module For use in residential and commercial PV installations MORE POWER PER MODULE Our 325W module generates 20% more power than a standard 270 W module. MORE ENERGY EVERY YEAR More yearly energy (kWh) compared to other modules as they perform better in the heat. MORE LAYERS, MORE POWER Manufactured by Panasonic for SolarCity, the module uses Heterolunction cell technology, which adds a layer of thin film silicon on top of high efficiency crystalline silicon. OUTSTANDING DURABILITY With more than 20 additional tests performed beyond what is currently mandated, these modules far exceed industry standards. LEADING WARRANTY Our modules rank among the best in warranty coverage, with workmanship that extends to 15 years. F° Rod LIMITED WARRANTY Power Output 10 years (90%of PM1ej 25 years (80% of P„J Workmanship 15 years MATERIALS Cell Material 51nch photovoltaic cells Glass Material AR coated tempered glass Frame Materials Black anodized aluminum CAUTION Please read the Installation manual carefully before using the product. Modules are manufactured by Panasonic to the specification of SolarCity. Modules are only warranted by Panasonic if the modules are included in a PV system sold by SolarClty or Tesla. SolarCity and Tesla make no warranties related to the modules, which are sold as -is. SolarCity will handle any warranty claims on behalf of any purchaser. SOLARCITY 1463095-00-B MODULE SPECIFICATIONS ELECTRICAL CHARACTERISTICS Model SC325 SC320 Max Power (M 325 320 Max Power Voltage, VYe M 57.6 57.3 Max Power Current, IMp (A) 5.65 5.59 Open Circuit Voltage, V. M 69.6 69.4 Short Circuit Current, I. (A) 6,03 5.98 System Voltage (V) 600 600 Max Series Fuse Rating (A) 15 15 Solar Module Efficiency (%) 19.4 19.1 Power Tolerance (%) +5 / -0 +5 / -0 AT NOCT (NORMAL OPERATING CONDITIONS) Model SC325 SC320 Max Power (W) 246.0 242.0 Max Power Voltage, VMe M 54.2 53.8 Max Power Current, Isp (A) 4.54 4.49 Open Circuit Voltage, V. M 66.0 65.8 Short Circuit Current, I. (A) 4.85 4.81 MECHANICAL DATA Weight 19.5kg (42.99 lbs) Dimensions 1590 mm (62.601 / 1053 mm (41.46") / 40 mm (1.57') Connector MC4 Frame Color Black Wind and Snow Load 2400 Pa (501bs/fti') Fire Type UL 1703 Type 2 pL��p$El�Y'a-_all Iasman SSectionA-K Section 11-11' SOLARCITY TEMPERATURE CORRECTION NOCT ('C) 44.0 Puy (%/'C) -0.29 Va (%/'C) -0.25 lu (%PC) 0.03 Electrical characteristics are within -/+10% of the indicated values of Ir and V. and +5/-0% for P„M, under standard test conditions irradiance of 100 mW/cm, AM 1.5 spectrum, and a cell temperature of 25 degrees Celsius or 77 degrees Fahrenheit). AT LOW IRRADIANCE (20%) Model Max Power (W) Max Power Voltage, V., (V) Max Power Current, IMe (A) Open Circuit Voltage, V. M Short Circuit Current, I. (A) 1463095-00-8 WE mEm_RA SC325 SC320 62.0 60.9 55.7 55.2 1.11 1.10 65.1 64.7 1.21 1.20 Unit mm on) 9