Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structuOrenty
located at 2924 Sherwood Lane, Saint Lucie County, Florida
Manufacturer:
Profiles:
Code:
Wind Speed:
Exposure:
Mean Roof Height:
Pitch:
Required Design Pressure:
Maximum Uplift Pressure:
Base:
Ply Sheet:
Cap:
Roof Decking:
Polyglass USA
Modified Bitumen Roof System, FL #1654-R22, System #W-141
FBC 2017; Section 905
160 MPH; Ultimate Design Wind Speeds
B
30' Maximum
.25/12 Minimum
Zonel: -26 Zone 2: -41 Zone3: -57
-90 psf
(self- adhering) Polyflex SA
(Optional) APP-TA
APP-TA
Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2,
and 4" O.C. thru out zone 3.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
i and the Manufacturer's recommendations.