Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEc/ FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CALIANDRO RESIDENCE Builder Name: DAVE GOLDEN HOMES Street 18002 BRIDLE WAY Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner: CALIANDRO Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1746.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1746.00 ft2 b. WA R= ft2 3. Number of units, fi multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2493.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=38.0 2493.00 ft2 6. Conditioned floor area above grade (W) 2493 b. N/A R= ft i c. NIA R= Conditioned floor area below grade (ft2) 0 11 Ducts R ft2 7. Windows(259.6 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: HALL 6 425 a. U-Factor. Sgl, U=0.54 259.83 112 SHGC: SHGC=0.32 12. Cooling systems kBtu/hr Efficiency b. U-Factor. WA ft2 a. Central Unit 46.5 SEER:16.00 SHGC: c. U-Factor WA ft2 SHGC: 13. Heating systems kBtufhr Efficiency d. U-Factor N/A ftZ a. Electric Strip Heat 34.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 5.152 ft. Area Weighted Average SHGC: 0.320 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2493.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2493.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat 0.104 Total Proposed Modified Loads: 74.47 PASS Glass/Floor Area: Total Baseline Loads: 75.65 1 hereby certify that the plans and specifications covered by Review of the plans and 118E S:pr this calculation are in compliance with the Florida nergy specifications covered by this tiD = g FOB Code. calculation indicates compliance with the Florida Energy Code. rnrn'•. r:'L �'`. 4 o p PREPAR,W B : _ - Before construction is completed ; DATE: - this building will be inspected for compliance with Section 553.908 I hereby certify that this buildin Isdesi ad, ' in compliance Florida Statutes. li yS COU �O with the Florida Energy Cod . OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 12/28/2016 9:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: CALIANDRO RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2493 Lot # Owner: CALIANDRO Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: DAVE GOLDEN HOMES Rotate Angle: 0 Street: 18002 BRIDLE WAY Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE 1 IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 2 39 I 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2493 22437 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 290 2610 No 2 1 1 Yes Yes Yes 2 WIC 99 891 No 0 1 Yes Yes Yes 3 M. BATH 92 828 No 0 1 Yes Yes Yes 4 BATH 2 60 540 No 0 1 Yes Yes Yes 15 BEDROOM 2 208 1872 No 1 1 1 Yes Yes Yes 6 BEDROOM 3 170 1530 No 1 1 1 Yes Yes Yes:-- 7 TLT. 12 108 No 0 1 No Yes Yes 8 GREAT ROOM 684 6156 No 2 1 Yes Yes Yes 9 KITCHEN 459 4131 Yes 0 1 Yes Yes Yes 10 BATH 3 72 648 No 0 1 Yes Yes Yes 11 BEDROOM 4 204 1836 No 1 1 1 Yes Yes Yes 1 12 LAUNDRY 70 630 No 0 1 Yes Yes Yes 13 HALL 73 657 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 31 It 0 I 290 ft' — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 11 ft 0 99 ft' — 0 1 0 Edge Insulatio M. BATH 8 ft 0 92 ft' 0 1 0 3 Slab -On -Grade — I4 Stab -On -Grade Edge Insulatio BATH 2 6 ft 0 60 ft' — 0 1 0 12/28/2016 9:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio BEDROOM 2 29 ft 0 208 IF — 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 3 25 ft 0 170 ft' 0 1 0 7 Slab -On -Grade Edge Insulatio TLT. 1 It 0 12 ft' — 0 1 0 8 Slab -On -Grade Edge Insulatio GREAT ROOM 15 ft 0 684 ft' — 0 1 0 9 Slab -On -Grade Edge Insulatio KITCHEN 27 ft 0 459 ft' — 0 1 0 10Slab-On-Grade Edge Insulatio BATH 3 6 ft 0 72 ft' — 0 1 0 _ 11Slab-On-Grade Edge Insulatio BEDROOM 4 29 It 0 204 ft' — 0 1 0 I 12Slab-On-Grade Edge Insulatio LAUNDRY 7 ft 0 70IF __ 0 1 0 I 13Slab-On-Grade Edge Insulatio HALL 1 ft 0 73 ft' — 0 1 0 ROOF j Roof Gable Roof Solar SA Emitt Emitt Deck Pitch VI # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2627 IF 414 ft' Medium 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2493 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) MASTER BEDRO 38 Blown 290 IF 0.1 Wood 2 Under Attic (Vented) WIC 38 Blown 99 IF 0.1 Wood 3 Under Attic (Vented) M.BATH 38 Blown 92IF 0.1 Wood TI 4 Under Attic (Vented) BATH 2 38 Blown 60 ft' 0.1 Wood TI 5 Under Attic (Vented) BEDROOM 2 38 Blown 208 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 3 38 Blown 170 ft' 0.1 Wood 7 Under Attic (Vented) TLT. 38 Blown 12 ft' 0.1 Wood 8 Under Attic (Vented) GREAT ROOM 38 Blown 684 ft' 0.1 Wood _ 9 Under Attic (Vented) KITCHEN 38 Blown 459 ft' 0.1 Woad _ 10 Under Attic (Vented) BATH 3 38 Blown 72 ft' 0.1 Wood _ 11 Under Attic (Vented) BEDROOM 4 38 Blown 204 ft' 0.1 Wood 12 Under Attic (Vented) LAUNDRY 38 Blown 70 IF 0.1 Wood 13 Under Attic (Vented) HALL 38 Blown 73 ft' 0.1 Wood 12/28/2016 9:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 F(ltAll RAnr-7n1A WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below -Omf Tn Wall Tenp SPa�e R-Valpo FI IR EI-In Area R-Value_. Fraction Ahenr rra _ 1 W Exterior Concrete Block - Ext Inffd4STER BE 4.1 15 0 9 0 135.0 ft' 0 0 0.6 0 -2 W Exterior Concrete Block- Ext InddASTER BE 4.1 16 0 9 0 144.0 it2 0 0 0.6 0 -3 W Exterior Concrete Block - Ext Insul WIC 4.1 11 0 9 0 99.0 ft' 0 0 0.6 0 -4 W Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 9 0 72.0 ft' 0 0 0.6 0 5 W Exterior Concrete Block- Ext Insul BATH 2 4.1 6 0 9 0 64.0 ft' 0 0 0.6 0 -6 W Exterior Concrete Block - Ext InfiEDROOM 2 4.1 16 0 9 0 144.0 ft' 0 0 0.6 0 -7 S Exterior Concrete Block - Ext InSEDROOM 2 4.1 13 0 9 0 117.0 ft' 0 0 0.6 0 -8 S Exterior Concrete Block - Ext InMEDROOM 3 4.1 13 0 9 0 117.0 ft' 0 0 0.6 0 -9 S Exterior Concrete Block - Ext InfiEDROOM 3 4.1 12 0 9 0 108.0 ft' 0 0 0.6 0 _ 10 S Exterior Concrete Block - Ext In3aREAT ROO 4.1 15 0 9 0 135.0 ft' 0 0 0.6 0 _ 11 N Exterior Concrete Block - Ext InsuKITCHEN 4.1 27 0 9 0 243.0 ft' 0 0 0.6 0 _ 12 W Exterior Concrete Block - Ext Insul BATH 3 4.1 6 0 9 0 54.0 ft' 0 0 0.6 0 _ 13 S Exterior Concrete Block - Ext IngffDROOM 4 4.1 12 0 9 0 108.0 ft' 0 0 0.6 0 _ 14 E Exterior Concrete Block - Ed InSEDR00M 4 4.1 17 0 9 0 153.0 ft' 0 0 0.6 0 15 E Exterior Concrete Block - Ext InsIllAUNDRY 4.1 7 0 9 0 63.0 ft' 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening _ 1 W 2 Metal Low-E Single Yes 0.54 0.32 30.0 ft' 2 It 0 in 1 ft 4 in None None _ 2 W 4 Metal Law-E Single Yes 0.54 0.32 6.0 ft' 2 ft 0 in 1 ft 4 in None None _ 3 W 5 Metal Low-E Single Yes 0.54 0.32 6.6 ft' 2 ft 0 in 1 ft 4 in None None _ 4 W 6 Metal Low-E Single Yes 0.54 0.32 30.0 ft' 2 ft 0 in 1 It 4 in None None _ 5 S 9 Metal Low-E Single Yes 0.54 0.32 30.0 ft' 2 It 0 in 1 ft 4 in None None _ 6 S 10 Metal Low-E Single Yes 0.54 0.32 40.8 ft' 8 ft 0 in 1 ft 4 in None None 7 N 11 Metal Low-E Single Yes 0.54 0.32 41.0 ft' 12 ft 0 in 1 ft 4 in None None 8 N 11 Metal Low-E Single Yes 0.54 0.32 30.0 ft' 2 It 0 in 1 ft 4 in None None 9 W 12 Metal Low-E Single Yes 0.54 0.32 16.4 ft' 12 ft 0 in 1 ft 4 in None None 10 E 14 Metal Low-E Single Yes 0.54 0.32 22.5 ft' 2 It 0 in 1 ft 4 in None None I 11 E 15 Metal Law-E Single Yes 0.54 0.32 6.5 ft' 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft' 400 ft' 40 ft 9 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 I1 Wholehouse Proposed ACH(50) .0004 2617.6 143.71 270.26 .2922 7 12/28/2016 9:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 ;:nou 'Rdf1F_9niA HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 46.5 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None i SOLAR HOT WATER SYSTEM FSEC Collector Storage Gen # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location , Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 425 ft' Attic 145 ft- Default Leakage HALL (Default) (Default) 1 1 TEMPERATURES Progremabl[e Ceiling Fans: ]Thermosta[[t:�]Y Heet ng [X) Jan [x] Feb [[ ]] (X) Mar [[ ]] L.1 �X] i ri Jun ] Jul [ ] ri Aug �X Sep (] L 1 Occtt f v Nov Dee Dec Venting [[ ]) Jan [[ ]1 Feb [[[[ii �x]ll) Mar ll�xll Apr May Jun 11 Jul [ E [ 11 Aug E 111 Sep lXl Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 1-1 ting (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 1 PM 68 68 68 68 68 68 68 68 68 68 66 66 1 12/28/2016 9:35 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CALIANDRO RESIDENCE Builder Name: DAVE GOLDEN HOMES Street: 18002 BRIDLE WAY Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. CALIANDRO Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawispace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors i12128/2016 9:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM! R406-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New, construction or existing i 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (W) 7. Windows*' Description a. J.-Factor. Sgi, U=0.54 SHGC: SHGC=0.32 b. U-Factor. N/A SHGC: c. U-Factor. WA SHGC: d. U-Factor. WA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 18002 BRIDLE WAY, FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 1746.00 fti Single-family b. NIA R= ft 1 c. N/A R= ft' 4 d. N/A R= ft' 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=38.0 2493.00 ft 2493 b. WA R= ft' c. N/A R= ft' Area 11. Ducts R ft' 259.83 ft' a. Sup: Attic, Ret: Attic, AH: HALL 6 425 ft° 12. Cooling systems kBtu/hr Efficiency ft' a. Central Unit 46.5 SEER:16.00 ft' 5.152 ft. 0.320 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2493.00 ft' b. NIA R= ft' c. N/A R= ft' 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits i I certify that this home has,complied with the Florida Energy Efficiency Code for Building Constriction through the above energ saving features which will be installed (or exceeded) in this home before final inspection. therwise, a new EPL Display Card will be completed based on installed Code compt4ozlz ures. Builder Signature: Date: /711743 1, li Address of New Home: Oct �� /t/�� ✓ City/FL Zip: kBtu/hr Efficiency 34.0 COP:1.00 Cap: 50 gallons EF: 0.95 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/28/2016 9:35 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1