FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
I
Project Name: Newman Residence Room by Room - Danas AC
Builder Name:
Street: 1 8124 S. Ocean Drive
Permit Office:
City, State, Zip: Diamond Sands, FL,
Permit Number:
Owner.
Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
I
1. New construction or existing New (From Plans)
9. Wall Types (12903.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 6946.00 ft'
b. Interior Wall, Interior
R=0.0 4075.70 ft'
3. Number of units, if multiple family 1
c. Concrete Block - Int Insul, Adjacent
R=4.1 1203.00 ft'
4. Number of Bedrooms 6
d. other (see details)
R= 678.00 ft'
10. Ceifing Types (5847.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 5847.00 ft
6. Conditioned floor area above grade (ft') 5847
b. N/A
R= ft.
Conditioned floor area below grade (ft� 0
R
11c. uctsN/A
R ft'
7. Windows(1221.6 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Kitchen 2nd Floor Zone 6 432
- a. U-Factor. Dbl, U=0.31 1221.60 ft'
b. Sup: Attic, Rat: Attic, AH: VIP Mstr 3rd Floor Zon 6 432
SHGC: SHGC=0.28
c. Sup: Attic, Ret: Attic, AH: Lounge 3rd
Floor Zone 6 412
b. U-Factor. N/A ff=
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit v�p
�ypp'
48.0 SEER:19.00
b. Central A�M�
48.0 SEER:19.00
c. U-Factor: NIA ft c.
Central Unit
48.0 SEER:19.00
SHGC:
``,rtll©
13. Healing systems B r
kBtu/hr Efficiency
d. U-Factor. N/A ft'
a. Electric Strip Heou'uCi
49.0 COP:1.00
SHGC:
b. Electric Strip Heat @ COUnty 49.0 COP:1.00
Area Weighted Average Overhang Depth: 7.805 ft.
c. Electric Strip Heat
49.0 COP:1.00
Area Weighted Average SHGC: 0.280
14. Hot water systems
a. Electric
Cap: 100 gallons
B. Floor Types (5847.0 sgft.) Insulation Area
ER 4.000
a. Floor over Garage R=19.0 3171.00 ft'
b. Conservation features
b. Floor Over Other Space R=0.0 2291.00 ft'
None
c. other (see details) R= 385.00 ft'
15. Credits
Pstat
0.209 Total Proposed Modified Loads: 119.29
PASS
Glass/Floor
Total Standard Reference Loads: 148.72
1 hereby certify that the pla s and specifications covered by
Review of the plans and
O11 E ST4r"
this calculation ar in liance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED B -_ t1
Before construction is completed
this building be inspected for
1•Q C
DATE: .. lid
will
I hereby certify thVhIsIdI'g,'a5 desi�r ned, is in com
Florida Statutes.twith
the Florida E
OD WE
OWNEWAGENBUILDING
OFFICIAL:DATE:
.--�}
DATE:
- Compliance requires certification by the air handler nufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 403.2.2. 1.
- Compliance requires completion of a Florida Air Ba fflid Insulation Inspection Checklist
12/4/2014 1:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 10
PROJECT
Title:
Newman Residence Room by
Bedrooms: 6
Address Type:
Street Address
Building Type:
User
Conditioned Area: 5847
Lot #
Owner:
Total Stories: 3
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook
Builder Name:
Rotate Angle: 0
Street:
8124 S. Ocean Drive
Permit Ofilce:
Cross Ventilation:
County:
St. Lucie
Jurisdictiop:
Whole House Fan:
City, State,
Zip:
Diamond Sands,
Family Type:
Single-family
FL,
New/Exist4ng:
New (From Plans)
Comment
CLIMATE
/
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location
TMY Site
Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL,IST
LUCIE_CO_INTL FL_ST LUCIE_CO_INTL 2 39
90
70
75
722
58
Medium
BLOCKS
Number
Name
Area
Volume
1
Blockt
2053
26689
2
Block2
1888
24544
3
Block3
1906
22872
SPACES
Numbet
Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
Elevator 1 st Floor Z
25
325 No
1
1
Yes
Yes
Yes
2
Foyer l st Floor Zon
360
4680 No
1
0
1
Yes
Yes
Yes
3
Kitchen 2nd Floor Z
854
11102 Yes
6
0
1
Yes
Yes
Yes
4
Prep Room 2nd Flo
237
3081 No
1
0
1
Yes
Yes
Yes
5
Dining 2nd Floor Zo
212
2756 No
0
0
1
Yes
Yes
Yes
6
Elevator 2nd Floor
25
325 No
0
0
1
Yes
Yes
Yes
7
Powder Room 2nd
40
520 No
0
0
1
Yes
Yes
Yes
8
N Sd of Living 2nd
300
3900 No
4
0
1
Yes
Yes
Yes
9
S Sd of Living 2nd
391
5083 No
0
0
1
Yes
Yes
Yes
10
Stairs
360
4680 No
0
0
1
Yes
Yes
Yes
11
Mstr Bed 2nd Floor
582
7566 No
2
1
1
Yes
Yes
Yes
12
Mist Bath 2nd Floor
256
3328 No
0
0
1
Yes
Yes
Yes
13
Studio
299
3887 No
0
1
1
Yes
Yes
Yes
14
Elevator 3rd Floor Z
25
300 No
0
0
1
Yes
Yes
Yes
15
VIP Mstr 3rd Floor
395
4740 No
0
1
1
Yes
Yes
Yes
16
VIP Bath 3rd Floor
120
1440 No
0
0
1
Yes
Yes
Yes
17
VIP WIC 3rd Floor
41
492 No
0
0
11
Yes
Yes
Yes
16
Hallway 3rd Floor Z
231
2772 No
0
0
1
Yes
Yes
Yes
19
Bed 2 3rd Floor Zon
237
2844 No
0
1
1
Yes
Yes
Yes
20
Bed 3 3rd Floor Zon
225
2700 No
0
1
1
Yes
Yes
Yes
1Zra¢u1l 1:J4 I'm energyuaugew uara - riameszvlu oecuon 4vo.w.1 uumpnam oonware rage c or iv
SPACES
Number Name Area _ Volume_
Kitchen Occupants
Bedrooms
Infil ID
Finished
Cooled
Heated
21 Bed 4 3rd Floor Zon 225 2700
No 0
1
1
Yes
Yes
Yes
22 Lounge 3rd Floor Z 347 4164
No 4
0
1
Yes
Yes
Yes
23 Utility 3rd Floor Zon 60 720
No 0
0
1
Yes
Yes
Yes
FLOORS
�# Floor_Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
--
�1 Slab -On -Grade Edge Insuiatio
Elevator 1st Floor
20 ft 0
-- —.
25 ft'
--
1
0
0
i2 Slab -On -Grade Edge Insulatio
Foyer 1st Floor Z
88 ft 0
360 ft'
—
1
0
0
13 Floor over Garage
Kitchen 2nd Floor
_ —
854 W
19
0'
1
0
14 Floor over Garage
Prep Room 2ndF
_ _—
237 ft'
19
0
1
0
5 Floor over Garage
Dining 2nd Floor
—
212 ft'
19
0
i
0
6 Floor Over Other Space
Elevator 2nd Floo
— —
25 ft'
0
1
0
0
7 Floor over Garage
Powder Room 2n
_
40 ft'
19
1
0
0
8 Floor over Garage
N Sd of Living 2n
_— —_
300 ft'
19
0
1.
0
9 Floor over Garage
S Sd of Living 2n
__ ____
391 ft'
19
0
1
0
10FIcor Over Other Space
Stairs
___
360 ft'
0
0
1
0
11Floor over Garage
Mstr Bed 2nd Flo
582 ft'
19
0
0
1
12FIoor over Garage
Mst Bath 2nd Flo
___ _
256 W
19
1
0
0
13FIoor over Garage
Studio
__ —
299 ft'
19
0
0
1
14FIoor Over Other Space
Elevator 3rd Floor
_ _—
25 ft'
0
1
0
0
15Floor Over Other Space
VIP Mstr 3rd Floo
— —
395 ft'
0
0
0
1
16Floor Over Other Space
VIP Bath 3rd Floo
_
120 ft'
0
1
0
0
17Floor Over Other Space
VIP WIC 3rd Floo
— —
41 ft'
0
0
0
1
18FIoor Over Other Space
Hallway 3rd Floor
_ ___
231 W
0
0
0
1
19Floor Over Other Space
Bed 2 3rd Floor Z
__ —
237 ft'
0
0
0
1
20FIoor Over Other Space
Bed 3 3rd Floor Z
_ __
225 ft-
0
0
0
1
21Floor Over Other Space
Bed 4 3rd Floor Z
— _
225 ft'
0
0
0
1
22FIoor Over Other Space
Lounge 3rd Floor
__ _—
347 ft'
0
0
0
1
_ 23FIoor Over Other Space
Utility 3rd Floor Z
—
60 ft'
0
0
0
1
I
12I412014 1:34 PM EnergyGaugeO USA- FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 10
ROOF
/
Roof
Gable
Roof Solar
SA Emitt
Emitt
Deck
Pitch
v
#
Type Materials Area
Area
Color Absor.
Tested
Tested
Insul.
(deg)
9
Hip
Metal 3977 fF
0 tF Unfinishe 0.96
No 0.7
No
0
26.6
1
ATTIC
/
V
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
#
I
Fullatticattic _._
ed
Vented
300
3556 ft2
N N
i
CEILING
_
#
Ceiling Type
_ Space
R Value _ _ _
Area _
Framing_Frac
Truss Type
_
1
Under Attic (Vented)
Elevator 1st Floor
30
25 ft'
0.11
Wood
_
2
Under Attic (Vented)
Foyer 1st Floor Z
30
360 ft'
0.11
Wood
_
'3
Under Attic (Vented)
Kitchen 2nd Floor
30
854 ft'
0.11
Wood
4
Under Attic (Vented)
Prep Room 2nd F
30
237 ft-
0.11
Wood
5
Under Attic (Vented)
Dining 2nd Floor
30
212 ft'
0.11
Wood
16
Under Attic (Vented)
Elevator 2nd Floo
30
25 fill
0.11
Wood
7
Under Attic (Vented)
Powder Room 2n
30
40 fF
0.11
Wood
8
Under Attic (Vented)
N Sd of Living 2n
30
300 R'
0.11
Wood
_
9
Under Attic (Vented)
S Sd of Living 2n
30
391 ft'
0.11
Wood
10
UnderAttic(Vented)
Stairs
30
360 R'
0.11
Wood
_
.11
Under Attic (Vented)
Mstr Bed 2nd Flo
30
582 ft'
0.11
Wood
12
Under Attic (Vented)
Mst Bath 2nd Flo
30
2561E
0.11
Wood
13
Under Attic (Vented)
Studio
30
299 ft'
0.11
Wood
_
14
Under Attic (Vented)
Elevator 3rd Floor
30
25 ft2
0.11
Wood
_
15.
Under Attic (Vented)
VIP Mstr 3rd Floo
30
395 fl'
0.11
Wood
16
Under Attic (Vented)
VIP Bath 3rd Floo
30
120 ft2
0.11
Wood
_
17
Under Attic (Vented)
VIP WIC 3M Floo
30
41 ft'
0.11
Wood
_
18
Under Attic (Vented)
Hallway 3rd Floor
30
231 ft2
0.11
Wood
_
19
Under Attic (Vented)
Bed 2 3N Floor Z
30
237 ft'
0.11
Wood
20
Under Attic (Vented)
Bed 3 3rd Floor Z
30
225 ft'
0.11
Wood
_
21
Under Attic (Vented)
Bed 4 3rd Floor 2
30
225 ft2
0.11
Wood
_
22
Under Attic (Vented)
Utility 3rd Floor Z
30
60 fI
0.11
Wood
_
23
Under Attic (Vented)
Lounge 3rd Floor
30
347 ft2
0.11
Wood
WALLS
/
Adjacent
Cavity Width
Space
Height
Sheathing Framing
Solar
Below
�#.-Omr
To -Wall Tye._
a_Value Ff In - --.Ft- In Area-R-Value Frarr'on-Absor.
Grade°
_ 1
N
Garage Concrete Block- Int Ins6levator 1st F
4.1 .6
13
78.0 ft-
0
0.75
0
_ 2
E
Garage Concrete Block - Int InsBlevator 1st F
4.1 6
13
78.0 ft-
0
0.75
0
_ 3
S
Foyer 1st ' Interior Block
Elevator 1st F
4.1 6
13
78.0 ft' 0
0
0.76
0
-4
W
Garage Concrete Block - Int InsBlevator 1st F
4.1 6
12
72.0 ft'
0
0.75
0
_ 5
W
Exterior Concrete Block - Int InsBbyer 1st Flo
4.1 25
13
325.0 ft-
0
0.75
0
6
N
Garage Concrete Block - Int Insffloyer 1 st Flo
4.1 25
0 13
325.0 ft-
0
0.75
0
I
12/4/2014 1:34 PM EnergyGauge® USA - FlaRes2610 Section 405.4.1 Compliant Software Page 4 of 10
WALLS
Adjacent
Cavity
Width.
Height
Sheathing
Framing
Solar
Below
#
__0mt--.To-IDIaILType
Space ---B VAIue.
_ Et In
__pt_ _In
.Area-.R-Value
Fmctioo-
bsor._Grade%o
_ 7
E
Garage
Concrete Block - Int InsBbyer 1st Flo
4.1
25
13
325.0 ft'
0
0.75
0
_ 8
S
Garage
Concrete Block - Int Ins6byer 1st Flo
4.1
25
13
325.0 ft'
0
0.75
0
_ 9
N
Exterior
Concrete Block - Int InsKitchen 2nd F
4.1
24
13
312.0 ft2
0
0.75
0
_ 10
E
Exterior
Concrete Block - Int Insditchen 2nd F
4.1
21
8
13
281.7 ft'
0
0.75
0
_ 11
S
Exterior
Concrete Block - Int insWtchen 2nd F
4.1
16
2
13
210.2 ft'
0
0.75
0
_ 12
N
Exterior
Concrete Block - Int InsNltchen 2nd F
4.1
23
4
13
303.3 ft'
0
0.75
0
_ 13
S
N Sd of I i
Interior Wall Kitchen 2nd F
0
16
13
208.0 ft'
0
0
0.75
0
_ 14
I W
Prep Roo
Interior Wall Kitchen 2nd F
0
21
8
13
281.7 ft'
0
0
0.75
0
_ 15
1 N
Exterior
Concrete Block - Int InsEirep Room 2
4.1
8
13
104.0 ft'
0
0.75
0
_ 16
W
Dining 2n
Interior Wall Prep Room 2
0
13
13
169.0 ft'
0
0
0.75
0
_ 17
N
Exterior
Concrete Block - Int Inslilrep Room 2
4.1
•14
13
182.0 ft'
0
0.75
0
_ 18
W
Exterior
Concrete Block - Int InsOlrep Room 2
4.1
7
13
91.0 W
0
0.75
0
_ 19
S
Dining 2n
Interior Wall Prep Room 2
0
14
13
182.0 ft,
0
0.75
0
20
W
Exterior
Concrete Bloch - Int Insaining 2nd FI
4.1
14
13
182.0 ft'
0
0.75
0
21
S
Exterior
Concrete Block - Int Insaining 2nd FI
4.1
6
13
78.0 ft'
0
0.75
0
22
N
Interior Wall Powder Roo
0
6
13
78.0 ft2
0
0
0.75
0
23
E
Elevator
Interior Block Powder Roo
4.1
6
13
78.0 ft2
0
0
0.75
0
24
S
Stairs
Interior Wall Powder Roo
0
6
13
78.0 ft2
0
0
0.75
0
25
W
Dining 2n
Interior Wall Powder Roo
0
6
13
78.0 ft
0
0
0.75
0
26
W
Exterior
Concrete Block- Int Insaining 2nd FI
4.1
6
13
78.0 IF
0
0.75
0
27
N
Prep Roo
Interior. Block Elevator 2nd
4.1
6
13
78.0 ft2
0
0
0.75
0
28
E
N Sd of Li
Interior Block Elevator 2nd
4.1
6
13
78.0 ft2
0
0
0.75
0
29
S
Stairs
Interior Block Elevator 2nd
4.1
6
13
78.0 ft2
0
0
0.75
0
30
E
Exterior
Concrete Block - Int InsNISd of Living
4.1
12
5
13
161.4 ft'
0
0.75
0
31
E
Exterior
Concrete Block - Int InsSISd of Living
4.1
12
5
13
161.4 ft-
0
0.75
0
_ 32
E
Mstr Bed
Interior Wall S Sd of Living
0
6
13
78.0 ft'
0
0
0.75
0
_ 33
E
Mstr Bed
Interior Wall S Sd of living
0
10
13
130.0 IF
0
0
0.75
0
_ 34
E
Mat Bath
Interior Wall S Sd of Living
0
4
13
52.0 ft'
0
0
0.75
0
35
W
Stairs
Interior Wall S Sd of Living
0
20
13
260.0 ft2
0
0
0.75
0
36
N
Exterior
Concrete Block - Int InsNstf Bed 2nd
4.1
19
13
247.0 ft2
0
0.75
0
37
E
Exterior
Concrete Block - Int InsABstr Bed 2nd
4.1
25
13
325.0 ft'
0
0.75
0
_ 38
S
Exterior
Concrete Block- Int Ins9lbtr Bed 2nd
4.1
19
13
247.0 ft'
0
0.75
0
_39
S
Exterior
Concrete Block - Int InAfttr Bed 2nd
4.1
9
13
117.0 ft'
0
0.75
0
_40
W
Mst Bath
Interior Wall Mstr Bed 2nd
0
7
13
91.0 ft.
0
0
0.75
0
41
S
Exterior
Concrete Block - Int InsMst Bath 2nd
4.1
17
13
221.0 ft2
0
0.75
0
42
W
Exterior
Concrete Block - Int Inslllst Bath 2nd
4A
2
13
26.0 fP
0
0.75
0
43
W
S Sd of LI
Interior Wall Mstr Bed 2nd
0
8
13
104.0 ft2
0
0
0.75
0
_44
W
Studio
Interior Wall Mst Bath 2nd
0
13
13
169.0 ft2
0
0
0.75
0
_45
S
Exterior
Concrete Block -Int Insul Studio
4.1
18
13
234.0 ft2
0
0.75
0
46
W
Exterior
Concrete Block - Int Insul Studio
4.1
14
13
182.0 ft'
0
0.75
0
_ 47
N
Exterior
Concrete Block - Int Insul Studio
4.1
2
13
26.0 ft2
0
0.75
0
48
N
Stairs
Interior Wall Studio
0
6
13
78.0 ft2
0
0
0.75
0
49
1 W
Exterior
Concrete Block - Int Insul Studio
4.1
6
13
78.0 ft2
0
0.75
0
121412014 1:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 10
WALLS
//
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar Below
°
�
�L-9__-Ornt
__7n
WalL?YpeSpace_..11Value_.
Ft -In-
Et-ln-.-
Area -_F3YaWe._-Enaction--Absor_-Grad
...
50
N
Stairs
Interior Wall Studio
0
11
13
143.0 ft'
0
0
0.75
0
51
W
Exterior
Concrete Block - Int Insul Stairs
4.1
25
13
325.0 ft'
0
0.75
0
_ 52
N
Exterior
Concrete Block - Int InsMIP Mstr 3rd
4.1
16
12
192.0 ft'
0
0.75
0
_ 53
E
Exterior
Concrete Block - Int InsMIP Mstr 3rd
4.1
21
12
252.0 W
0
0.75
0
54
S
Exterior
Concrete Block - Int InsMIP Mstr 3rd
4.1
16
12
192.0 ft'
0
0.75
0
55
W
VIP Bath
Interior Wall VIP Mstr 3rd
0
12
13
156.0 ft'
0
0
0.75
0
56
W
VIP WIC
Interior Wall VIP Mstr 3rd
0
5
12
60.0 ft'
0
0
0.75
0
57
N
Exterior
Concrete Block - Int Ins6NP Bath 3rd
4.1
10
12
120.0 ft'
0
0.75
0
_58
S
Hallway 3
Interior Wall VIP Bath 3M
0
10
12
120.0 IF
0
0
0.75
0
_59
W
Bed 2 3rd
Interior Wall VIP Bath 3rd
0
12
12
144:0 ft'
0
0
0.75
0
60
N
Exterior
Concrete Block - Inl InsMad 2 3rd Flo
4.1
5
12
60.0 IF
0
0.75
0
61
S
Hallway 3
Interior Wall Bed 2 3rd Flo
0
5
12
60.0 ft'
0
0
0.75
0
62
N
Exterior
Concrete Block -Int lnsBled 2 3rd Flo
4.1
14
12
168.0 ft'
0
0.75
0
63
W
Exterior
Concrete Block - Int lnsBled 2 3rd Flo
4.1
21
12
252.0 ft'
0
0.76
0
64
S
Hallway 3
Interior Wall Bed 2 3rd Flo
0
9
12
108.0 ft'
0
0
0.75
0
65
E
Hallway 3
Interior Wall Bed 2 3rd Flo
0
8
12
96.0 ft'
0
0
0.75
0
66
S
Elevator
Interior Block Bed 2 3rd Flo
4.1
6
12
72.0 ft'
0
0
0.75
0
67
E
Hallway 3
Interior Block Elevator 3rd F
4.1
6
12
72.0 ft'
0
0
0.75
0
68
S
Lounge 3r
Interior Block Elevator 3rd F
4.1
6
12
72.0 ft'
0
0
0.75
0
69
W
Utility 3rd
Interior Block Elevator 3rd F
4.1
6
12
72.0 ft'
0
0
0.75
0
_ 70
N
Exterior
Concrete Block - Int InsWtility 3rd Flo
4.1
11
12
132.0 ft-
0
0.75
0
71
W
Exterior
Concrete Block - Int InsWtility 3rd Flo
4.1
6
12
72.0 ft'
0
0.75
0
72
S
Lounge 3r
Interior Wall Utility 3rd Flo
0
11
12
132.0 ft'
0
0
0.75
0
73
W
Exterior
Concrete Block - Int Insbbunge 3rd FI
4.1
19
12
228.0 ft'
0
0.75
0
74
S
Exterior
Concrete Block - Int Inslubunge 3rd FI
4.1
17
12
204.0 IF
0
0.75
0
75
E
Bed 4 3rd
Interior Wall Lounge 3rd FI
0
8
12
96.0 ft'
0
0
0.75
0
76
E
Bed 4 3rd
Interior Wall Lounge 3rd FI
0
5
12
60.0 ft'
0
0
0.75
0
77
S
Exterior
Concrete Block - Int InsObd 4 3rd Flo
4.1
9
12
108.0 ft'
0
0.75
0
78
S
Exterior
Concrete Block - Int Malted 4 3rd Flo
4.1
13
12
156.0 ft'
0
0.75
0
79
E
Exterior
Concrete Block - Int Inslllad 4 3rd Flo
4.1
13
12
156.0 ft'
0
0.75
0
_ 80
N
Bed 3 3rd
Interior Wall Bed 4 3rd Flo
0
12
12
144.0 R'
0
0
0.75
0
81
N
Hallway 3
Interior Wall Bed 4 3rd Flo
0
8
12
96.0 ft'
0
0
0.76
0
82
W
Hallway 3
Interior Wall Bed 3 3rd Flo
0
8
12
96.0 ft'
0
0
0.75
0
83
S
Hallway 3
Interior Wall Bed 3 3rd Flo
0
6
12
60.0 ft
0
0
0.75
0
84
N
VIP WIC
Interior Wall Bed 3 3rd Flo
0
10
12
120.0 it!
0
0
0.75
0
85
E
Exterior
Concrete Block - Int InsBLd 3 3rd Flo
4.1
13
12
156.0 ft'
0
0.75
0
86
W
Hallway 3
Interior Wall Bed 3 3rd Flo
0
7
12
84.0 ft-
0
0
0.75
0
87
N
Hallway 3
Interior Wall Bed 3 3rd Flo
0
8
12
96.0 ft'
0
0
0.75
0
88
E
VIP WIC
Interior Wail Bed 3 3rd Flo
0
4
12
48.0 ft°
0
0
0.75
0
89
N
Interior Wall VIP WIC 3rd
0
10
12
120.0 ft'
0
0
0.75
0
12/412014 1:34 PM EnergyGauge® USA- F1aRes20l0 Section 405.4.1 Compliant Software Page 6 of 10
DOORS
�#
Omt
Door Type
Space
Storms
U-Value
Width
Area
Ft
In
F`eightln
1
W
Wood
Foyer 1st Flo
None
.46
3
6
9
31.5 ft
_
_ 2
N
Wood
Foyer 1st Flo
None
.46
2
8
8
21.3 ft'
_ 3
N
Wood
Foyer 1st Flo
None
.46
5
8
40 ft'
_ 4
E
Wood
Foyer 1st Flo
None
.46
3
8
24 ft'
_ 5
W
Wood
Stairs
None
.46
3
6
6
28 ft'
_ 6
N
Wood
Mstr Bed 2nd
None
AS
2
8
10
26.7 ft'
7
W
Wood
Lounge 3rd Ft
None
.46
2
8
8
21.3 ft
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
#
Omt
ID
Frame
_ Panes
NFRC
U-Factor
S_HGC
_
Area
Depth
Separation
Int Shade
Screening
_ 1
W
5
Vinyl
Double (Tinted)
Yes
0.31
0.28
44.0 ft'
2 ft 0 in
2 ft 0 in
None
None
_ 2.
W
5
Vinyl
Double (Tinted)
Yes
0.31
0.28
7.0 ft'
2 ft 0 in
2 ft 0 in
None
None
3
N
52
Vinyl
Double (Tinted)
Yes
0.31
0.28
25.0 ft'
2 ft 0 in
4 ft 0 in
None
None
_ 4
N
62
Vinyl
Double (Tinted)
Yes
0.31
0.28
25.0 ft'
2 It 0 in
4 ft 0 in
None
None
_ 5
N
57
Vinyl
Double (Tinted)
Yes
0.31
0.28
25.0 ft'
2 ft 0 in
4 ft 0 in
None
None
_ 6,
N
57
Vinyl
Double (Tinted)
Yes
0.31
0.28
8.0 ft'
2 ft 0 in
4 ft 0 in
None
None
7
E
53
Vinyl
Double (Tinted)
Yes
0.31
0.28
75.01N
2 ft 0 in
4 ft 0In
None
None
8
E
85
Vinyl
Double (Tinted)
Yes
0.31
0.28
84.0 ft2
9 ft 0 in
4 ft 0 in
None
None
_ 9
W
71
Vinyl
Double (Tinted)
Yes
0.31
0.28
12.5 ft
6 ft 0 in
4 ft 0 in
None
None
_ 10
W
63
Vinyl
Double (Tinted)
Yes
0.31
0.28
25.0 ft'
2 ft 0 in
4 ft 0 in
None
None
_ 11
E
79
Vinyl
Double (Tinted)
Yes
0.31
0.28
72.0 ft'
9 ft 0In
4 ft 0 In
None
None
12
W
73
Vinyl
Double [tinted)
Yes
0.31
0.28
12.5 ft-
6 ft 0 in
4 ft 0 in
None
None
13
W
73
Vinyl
Double (Tinted)
Yes
0.31
0.28
32.0 ft2
6 ft 0 in
4 ft 0 in
None
None
_ 14
N
15
Vinyl
Double (Tinted)
Yes
0.31
0.28
13.5 ft'
2 ft 0 in
5 ft 0 In
None
None
_ 15
N
15
Vinyl
Double (Tinted)
Yes
0.31
0.28
6.0 ft'
2 ft 0 in
3 ft 0 in
None
None
_ 16
N
12
Vinyl
Double (Tinted)
Yes
0.31
0.28
45.0 ft2
2 ft 0 in
5 ft 0In
None
None
_ 17
N
12
Vinyl
Double (Tinted)
Yes
0.31
0.28
20.0 ft2
2 ft 0 in
3 ft 0In
None
None
18
E
10
Vinyl
Double (Tinted)
Yes
0.31
0.28
42.0 ft2
2 ft 0 in
5 ft 0 in
None
None
_ 19
E
10
Vinyl
Double (Tinted)
Yes
0.31
0.28
0.8 112
2 ft 0 in
3 ft 0 in
None
None
_ 20
E
10
Vinyl
Double (Tinted)
Yes
0.31
0.28
24.0 ft'
2 ft 0 In
5 ft 0 in
None
None
_ 21
E
30
Vinyl
Double (Tinted)
Yes
0.31
0.28
110.0 ft'
19 ft 0 in
3 ft 0 in
None
None
_ 22
S
11
Vinyl
Double (Tinted)
Yes
0.31
0.28
50.0 ft-
25 ft 0 in
3 ft 0 in
None
None
23
S
11
Vinyl
Double (Tinted)
Yes
0.31
0.28
25.0 ft2
25 ft 0 in
3 ft 0 in
None
None
_ 24
W
26
Vinyl
Double (Tinted)
Yes
0.31
0.28
15.0 ft2
6 ft 0 in
5 ft 0 in
None
None
_ 25
W
26
Vinyl
Double (Tinted)
Yes
0.31
0.28
6.0 ft2
6 ft 0 in
3 ft 0 in
None
None
_ 26
W
20
Vinyl
Double (Tinted)
Yes
0.31
0.28
45.0 ft2
2 ft 0 in
5 ft 0 in
None
None
27
W
20
Vinyl
Double (Tinted)
Yes
0.31
0.28
18.0 ft2
2 ft 0In
3 ft 0 in
None
None
_ 28
W
20
Vinyl
Double (Tinted)
Yes
0.31
0.28
18.0 ft'
ft 0 in
10 ft 0 in
None
None
29
W
18
Vinyl
Double (Tinted)
Yes
0.31
0.28
11.3 ft2
ft 0 in
5 ft 0 in
None
None
_ 30
W
18
Vinyl
Double tented)
Yes
0.31
0.28
5.0 ft2
2 ft 0In
3 ft 0 in
None
None
31
E
31
Vinyl
Double (Tinted)
Yes
0.31
0.28
100.0 ft2
19 ft 0 in
3 ft 0 in
None
None
32
E
37
Vinyl
Double (Tinted)
Yes
0.31
0.28
30.0 ft2
9 ft 0 in
5 ft 0 in
None
None
12141201'4 1:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 7 of 10
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Omt ID Frame
Panes NF_RC
U-Fodor SHGC
-
Area Depth
-
Separation Int Shade
Screening
_ 33
_
E 37 Vinyl
Double (Tinted) Yes
0.31 0.28
6.0 ft' 9 ft 0 in
3 ft 0 in
None
None
34.
E 37 Vinyl
Double (Tinted) Yes
0.31 0.28
20.0 ft- 9 It 0 in
6 it 0 in
None
None
35.
5 38 Vinyl
Double (Tinted) Yes
0.31 0.28
12.5 ft2 2 it 0 in
5 ft O In
None
None
36
S 38 Vinyl
Double (Tinted) Yes
0.31 0.28
6.0 ft2 2 ft 0 in
3 It 0 in
None
None
37
S 45 Vinyl
Double (Tinted) Yes
0.31 0.28
12.5 ft' 2 It 0 In
5 ft 0 In
None
None
38
S 45 Vinyl
Double (Tinted) Yes
0.31 0.28
5.0 ft- 2 It 0 in
3 It 0 in
None
None
_ 36
S 41 Vinyl
Double (Tinted) Yes
0.31 0.28
20.0 ft' 2 It 0 In
5 ft 0 In
None
None
40
S 41 Vinyl
Double (Tinted) Yes
0.31 0.28
8.0 f 2 2 It 0 in
3 It 0 in
None
None
_ 41
S 41 Vinyl
Double (Tinted) Yes
0.31 0.28
25.0 ft' 2 ft 0 in
5 ft 0 in
None
None
_ 42
5 41 Vinyl
Double (Tinted) Yes
0.31 0.28
10.0 ft' 2 ft 0 in
3 ft 0 in
None
None
_ 43
W 46 Vinyl
Double (Tinted) Yes
0.31 0.28
25.0 ft' 2 It 0 in
5 It 0 in
None
None
_ 44
W 46 Vinyl
Double (Tinted) Yes
0.31 0.28
10.0 ft' 2 It 0 in
3 It 0 in
None
None
45
W 46 Vinyl
Double (Tinted) Yes
0.31 0.28
10.0 R' 2 It 0 in
10 It 0 in
None
None
_ 46
W 49 Vinyl
Double (Tinted) Yes
0.31 0.28
10.0 ft- 2 It 0 in
5 ft 0 in
None
None
47
W 49 Vinyl
Double (Tinted) Yes
0.31 0.28
5.0 ft' 2 It 0 in
3 ft 0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height_
Exposed Wall Insulation
_
1
3192 ft'
0 ft2
284 ft
1311
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH.50
1 Wholehouse Best Guess
.0003
4601 252.59 475.03 .3128
3.7253
HEATING SYSTEM
#
System Type
Subtype
Efficiency
_ Capacity
_ _Block
Ducts
_ 1
_
Electric Strip Heat None
COP: 1
49 kBtu/hr
1
sys#1
2
Electric Strip Heal None
COP: 1
49 kBtu/hr
2
sys#2
3
Electric Strip Heat None
COP: 1
49 kBtu/hr
3
sys#3
COOLING SYSTEM
System Type
_ Subtype
_ Efficiency
Capacity Air Flow SHR
Block_
Duds
_ 1
Central Unit
None
SEER: 19
48 kStulhr 1440 Cfm 0.7
1
sys#1
2
Central Unit
None
SEER 19
48 kBtu/hr 1440 cfm 0.7
2
sys#2
3
Central Unit
None
SEER: 19
48 kBtu/hr 1440 cfm 0.7
3
sys#3
12/4/2014 1:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 8 of 10
HOT WATER SYSTEM
#_ System Type
SubTy_pe
Location_EF
_ Cap
Use _
SetPnt
Conservation
_
1 Electric
Heat Pump
Garage
4 100 gal
90 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft'
DUCTS
— Supply —
— Return —•-
Air
CFM 25 CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
ON
RLF
Heat Cool
1
Attic
6 432 ft'
Attic
268 ft' Default Leakage
Kitchen 2nd
(Default) (Default)
1 1
_ 2
Attic
6 432 ft'
Attic
2951N Default Leakage
VIP Mstr 3r
(Default) (Default)
2 2
_ 3
Attic
6 412 W
Attic
287 ft' Default Leakage
Lounge.3rd
(Default) (Default)
3 3
TEMPERATURES
Pfogramabl[re%']ThermostaJan�[tX:]]Y
Ceiling Fans:Cooling
fFeb[X�]
�X�
Apr
rD0' [r
May Jun Jul
frX
Aug
([X r IfX
Sep Oct
NovrX,I
Nov
Nov
Dec
(
Dec
Venting [ ]Jan
( )Feb
[X) Mar
[ [ ] [
[
[
[X�
[ j
Thermostat'Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (VJD)
PM
78
78 78 78
78
78 78
78
78
80
80
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
12/4/2014 1:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 9 of 10
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 8124 S. Ocean Drive PERMIT M
Diamond Sands, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage ! 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
i
Thermostat & 403.1 1 At least one thermostat shall be provided for each separate heating and
controls cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas ,
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat>10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
12141201411:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 10 of 10
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 80
The lower the EnergyPerformance Index, the more efficient the home.
8124 S. Ocean Drive, Diamond Sands, FL,.
1. New construction or existing
New (From Plans)
2. Single family or multiple family
Single-family
3. Number of units, if multiple family
1
4. Number of Bedrooms
6
5. Is this a worst case?
No
6. Conditioned floor area (112)
5847
7. Windows'* Description
Area
a. U-Factor: Dbl, U=0.31
1221.60 112
SHGG: SHGC=0.28
b. U-Factor. N/A
ft2
SHGG:
c. U-Factor. N/A
ft2
SHGG:
d. U-Factor. NIA
ft2
SHGG:
Area Weighted Average Overhang Depth:
7.805 ft.
Area Weighted Average SHGC:
0.280
S. Floor Types
Insulation
Area
a. Floor over Garage
R=19.0
3171.00 fN
b. Floor Over Other Space
R=O.O
2291.00 fN
c. other (see details)
R=
385.00 ft2
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1
6946.00 ft2
b. Interior Wall, Interior
R=0.0
4075.70 ft2
c. Concrete Block - Int Insul, Adjacent
R=4.1
1203.00 ft2
d. other (see details)
R=
678.00 112
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
5547.00 ft2
b. N/A
R=
ft2
c. NIA
R=
ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Kitchen 2nd Floor Zone
6 432
b. Sup: Attic, Ret: Attic, AH: VIP Mstr 3rd Floor Zen
6 432
c. Sup: Attic, Ret: Attic, AH: Lounge 3rd
Floor Zone
6 412
12. Cooling systems
kBtu/hr
Efficiency
a. Central Unit
48.0 SEER:19.00
b. Central Unit
48.0 SEER:19.00
c. Central Unit
48.0 SEER:19.00
13. Heating systems
kStu/hr
Efficiency
a. Electric Strip Heat
49.0
COP:1.00
b. Electric Strip Heat
49.0
COP:1.00
c. Electric Strip Heat
49.0
COP:1.00
14. Hot water systems
a. Electric
Cap:
100 gallons
EF: 4
b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Cod mpli t features. _
BuilderSignature: - -`=r r te:
Address of New Home: City/FL Zip:
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
"Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Residential System Sizing Calculation
Summary
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
Location for weather data: Fort Pierce, FL - Defaults: Latitude(27.48) Altitude(25 ft.) Temp Range(L)
Humidi data: Interior RH 50%
Outdoor
wet bulb 79F Humiditv difference 72 r.
Winter design temperature(MJ8 99%) 39
F
Summer design temperature(MJ8
99%) 90
F
Winter setpoint
70
F
Summer setpoint
75
F
Winter temperature difference
31
F
Summer temperature difference
15
F
Total heating load calculation
96471
Btuh
Total cooling load calculation
12WS
Btuh
Submitted heating capacity
% of talc
Btuh
Submitted cooling capacity
% of talc
Btuh
Total, (Electric Strip Heat)
152.4
147000
Sensible (SHR = 0.70)
113.1
100800
Latent
119.0
43200
Total
114.8
144000
WINTER CALCULATIONS
IMM., ue.ri.. I n.,l Rnr FRd7 coal
Loadlcom onent
Load
Windowtotal
1222
sqft
11739
Btuh
Wall total
11488
sqft
26086
Btuh
Doortotal
193
sqft
2750
Btuh
Ceiling total
5847
sqft
5773
Btuh
Floor total
See detail report
8880
Btuh
Infiltration
618
cfm
21064
Btuh
Duct loss
20178
Btuh
Subtotal
96471
Btuh
Ventilation
0
cfm
0
Btuh
TOTAL HEAT LOSS
96471
Btuh
Rummpr Cnnlinc Lnad (for 5847 saft)
D.d.(21%)
NR(Z )
SUMMER CALCULATIONS
Load component
Load
Window total
1222 sqft
24818
Btuh
Wall total
11488 sqft
12622
Btuh
Door -total
193 sqft
2661
Btuh
Ceiling total
5847 sqft
8193
Btuh
Floor total
2226
Btuh
Infiltration
464 cfm
7644
Btuh
Internal gain
9870
Btuh
Ductigain
20955
Btuh
Sens. Ventilation
0 cfm
0
Btuh
Blower Load
147
Btuh
Total sensible gain
89138
Btuh
Latent gain(ducts)
9834
Btuh
Latent gain(infiltration)
22683
Btuh
Latent gain(ventilation)
0
Btuh
Latent gain(intemaUoccupants/other)
3800
Btuh
Total latent gain
36317
Btuh
TOTAL HEAT GAIN
125455
Btuh
M'r.r
w
11flNU8L1
�� vvwawanz%)
EnergyGauge ys , zin
PREPARED B .
DATE:
EnergyGauge® / USRFZB 0.1
Residential Window Diversity
MidSummer
Project Title:
8124'S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
Summer design temperature
90
F
Average window load for July
16660 Btu
Cooling setpoint
75
F
Peak window load for July
21549 Btu
Summer temperature difference
15
F
Excusion limit(130% of Ave.)
21658 Btu
Latitude
27.46
North
Window excursion Jul)
None
WINDOW Average and Peak Loads
22000.00 Limit for excursion
21000.00
20000.00
19000.00
1800010
17000.00 12 Hour Average
16000.00
15000.00 /
14000.00 /
M 13D60.00 /
m 12000.00
1160D.00
0 10000.00
9D00.00
8000.00
7000.00
6000.00
500D.00
4660.00
30D0.00
2000.00
1D00.00
0.00
a a.m. 10 12 2 p.m 4 p.m. 6 p.m. a p.m.
a.m.
Total July Window Load(Radiation and conduction)
The midsummer window load for this house does not exceed the window load excursion limit.
This house has adequate midsummer window diversity.
EnergyGauge® y tam g r Florida residences only
PREPARED BY: _
DATE:
EneravGaU / USRFZB v3.1
Residential Window Diversity
October
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/412014
Summer design temperature
90
F
Average window load for October
19566 Btu
Cooling setpoint
75
F
Peak window load for October
23369 Btu
Summer temperature difference
15
F
Excusion limit(130% of Ave.)
25436 Btu
Latitude
27.48
North
Window excursion October
None
WINDOW Average and Peak Loads
Limit for excursion
24000.00
22000.00 ----
20000.00 12 Hour Average
18000.00
16000.00ra
\\\
m 14000.00 ` \
0 l/ 12000.00
a
iDD00.00
8000.00
6000.00
OWN
20DO.00
0.00
8 s.m 10 12 2 P.M. 4 P.M. 6 p.m. 8 p.m
a.m.
Total October Window Load(Radiation and conduction)
The October window load for this house does not exceed the window load excursion limit
This house has adequate Oaober window diversity.
z
�:tbjs
.:Fd�r ri
-nettuw. i
USRFZB v3.1
System Sizing Calculations - Winter
Residential Load - Whole House Component Details
6124 S. Ocean Drive
Diamond Sands, FL
Project Title:
Newman Residence Room by Room - Danes AC
Building Type: User
12/4/2014
Reference City: Fort Pierce, FL (Defaults) Winter Temperature Difference: 31.0 F (MJ8 99%)
EnergyGauge® I USRFZB v3.1 Page 1
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
1
2,
NFRC 0.28
Vinyl
0.31
W
44.0
9.6
423 Btuh
2
2,
NFRC 0.28
Vinyl
0.31
W
7.0
9.6
67 Btuh
3
2,
NFRC 0.28
Vinyl
0.31
N
25.0
9.6
240 Btuh
4
2,
NFRC 0.28
Vinyl
0.31
N
25.0
9.6
240 Btuh
5
2,
NFRC 0.28
Vinyl
0.31
N
25.0
9.6
240 Btuh
6
2,
NFRC 0.28
Vinyl
0.31
N
8.0
9.6
77 Btuh
7
2,
NFRC 0.28
Vinyl
0.31
E
75.0
9.6
721 Btuh
8
2,
NFRC 0.28
Vinyl
0.31
E
84.0
9.6
807 Btuh
9
2,
NFRC 0.28
Vinyl
0.31
W
12.5
9.6
120 Btuh
10
2,
NFRC 0.28
Vinyl
0.31
W
25.0
9.6
240 Btuh
11
2,
NFRC 0.28
Vinyl
0.31
E
72.0
9.6
692 Btuh
12
2,
NFRC 0.26
Vinyl
0.31
W
12.5
9.6
120 Btuh
13
2,
NFRC 0.28
Vinyl
0.31
W
32.0
9.6
308 Btuh
14
2,
NFRC 0.28
Vinyl
0.31
N
13.5
9.6
130 Btuh
15
2,
NFRC 0.28
Vinyl
0.31
N
6.0
9.6
58 Btuh
16
2,
NFRC 0.28
Vinyl
0.31
N
45.0
9.6
432 Btuh
17
2,
NFRC 0.28
Vinyl
0.31
N
20.0
9.6
192 Btuh
18
2,
NFRC 0.28
Vinyl
0.31
E
42.0
9.6
404 Btuh
19
2,
NFRC 0.28
Vinyl
0.31
E
6.8
9.6
66 Btuh
20
2,
NFRC 0.28
Vinyl
0.31
E
24.0
9.6
231 Btuh
21
2,
NFRC 0.28
Vinyl
0.31
E
110.0
9.6
1057 Btuh
22
2,
NFRC 0.28
Vinyl
0.31
S
50.0
9.6
480 Btuh
23
2,
NFRC 0.2B
Vinyl
0.31
S
25.0
9.6
240 Btuh
24
2,
NFRC 0.28
Vinyl
0.31
W
15.0
9.6
144 Btuh
25
2,
NFRC 0.28
Vinyl
0.31
W
6.0
9.6
58 Btuh
26
2,
NFRC 0.28
Vinyl
0.31
W
45.0
9.6
432 Btuh
27
2,
NFRC 0.28
Vinyl
0.31
W
18.0
9.6
173 Btuh
28
2,
NFRC 0.28
Vinyl
0.31
W
18.0
9.6
173 Btuh
29
2,
NFRC 0.28
'Vinyl
0.31
W
11.3
9.6
108 Btuh
30
2,
NFRC 0.28
Vinyl
0.31
W
5.0
9.6
48 Btuh
31
2,
NFRC 0.28
Vinyl
0.31
E
100.0
9.6
961 Btuh
32
2,
NFRC 0.28
Vinyl
0.31
E
30.0
9.6
288 Btuh
33
2,
NFRC 0.28
Vinyl
0.31
E
6.0
9.6
58 Btuh
34
2,
NFRC 0.28
Vinyl
0.31
E
20.0
9.6
192 Btuh
35
2,
NFRC 0.28
Vinyl
0.31
S
12.5
9.6
120 Btuh
36
2,
NFRC 0.28
Vinyl
0.31
S
5.0
9.6
48 Btuh
37
2,
NFRC 0.28
Vinyl
0.31
S
12.5
9.6
120 Btuh
38
2,
NFRC 0.28
Vinyl
0.31
S
5.0
9.6
48 Btuh
39
2,
NFRC 0.28
Vinyl
0.31
S
20.0
9.6
192 Stuh
40
2,
NFRC 0.28
Vinyl
0.31
S
8.0
9.6
77 Btuh
41
2,
NFRC 0.28
Vinyl
0.31
S
25.0
9.6
240 Btuh
42
2,
NFRC 0.28
Vinyl
0.31
S
10.0
9.6
96 Btuh
43
2,
NFRC 0.28
Vinyl
0.31
W
25.0
9.6
240 Btuh
44
2,
NFRC 0.28
Vinyl
0.31
W
10.0
9.6
96 Btuh
45
2,
NFRC 0.28
Vinyl
OE%IrgyGaugN/USRFZB%13010
9.6
96 Btuh
Page 2
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4I2014
Window Panes/SHGC/Frame/U
46 2, NFRC 0.28 Vinyl
47 2, NFRC 0.28 Vinyl
Orientation Area X
0.31 W 10.0
0.31 W 5.0
EnergyGauge®! USRFZB v3.1
HTM= I Load
9.6 96 Btuh
9.6 48 Btuh
Page 3
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12l4/2014
Walls
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
Type Omt. Ueff. R-Value Area X
(Cav/Sh)
Cone Blk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone BlUilled
Cone Blk,Filled
Cone Blk,Filled
Cone BlUilled
Cone Blk,Filled
Cone BIk,Filled
Cone BIk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone Blk,Filled
Cone BlUilled
Cone Blk,Filled
Cone Blk,Filled
- Adj
- Adj
- Int
- Adj
- Ext
- Adj
- Adj
- Adj
-Ext
- Ext
- Ext
- Ext
- Int
- Int
- Ext
- Int
- Ext
- Ext
- Int
- Ext
- Ext
- Int
- Int
- Int
- Int
- Ext
- Int
- Int
- Int
- Ext
- Ext
- Int
- Int
- Int
- Int
- Ext
- Ext
- Ext
- Ext
- Int
Cone Blk,Hollow - Ext
Cone Blk,Filled - Ext
- Int
- Int
Cone Blk,Filled
- Ext
Cane Blk,Filled
- Ext
Cone Blk,Filled
- Ext
(0.124)
4.1/0.0
78
(0.124)
4.1/0.0
78
(0.124)
4.1/0.0
78
(0.124)
4.1/0.0
72
(0.124)
4.110.0
243
(0.124)
4.1/0.0
264
(0.124)
4.1/0.0
301
(0.124)
4.1/0.0
325
(0.124)
4.1/0.0
312
(0.124)
4.1/0.0
209
(0.124)
4.1/0.0
135
(0.124)
4.1/0.0
238
(0.124)
0.010.0
208
(0.124)
0.0/0.0
282
(0.124)
4.1/0.0
85
(0.124)
0.010.0
169
(0.124)
4.1/0.0
182
(0.124)
4.1/0.0
75
(0.124)
0.0/0.0
182
(0.124)
4.1/0.0
101
(0.124)
4.1/0.0
78
(0.124)
0.0/0.0
78
(0.124)
4.1/0.0
78
(0.124)
0.0/0.0
78
(0.124)
0.010.0
78
(0.124)
4.1/0.0
57
(0.124)
4.1/0.0
78
(0.124)
4.1/0.0
78
(0.124)
4.1/0.0
78
(0.124)
4.1/0.0
51
(0.124)
4.1/0.0
61
(0.124)
0.0/0.0
78
(0.124)
0.0/0.0
130
(0.124)
0.0/0.0
52
(0.124)
0.0/0.0
260
(0.124)
4.110.0
220
(0.124)
4.1/0.0
269
(0.124)
4.1/0.0
230
(0.124)
4.1/0.0
117
(0.124)
0.0/0.0
91
(0.149)
4.1/0.0
158
(0.124)
4.1/0.0
26
(0.124)
0.010.0
104
(0.124)
0.0/0.0
169
(0.124)
4.110.0
217
(0.124)
4.110.0
137
(0.1 Z4�rgyGaudWI101l�RFZB 4.6
HTM=
3.86
3.86
0.00
3.86
3.86
3.86
3.86
3.86
3.86
3.86
3.86
3.86
0.00
0.00
3.86
0.00
3.86
3.86
0.00
3.86
3.86
0.00
0.00
0.00
0.00
3.86
0.00
0.00
0.00
3.86
3.86
0.00
0.00
0.00
0.00
3.86
3.86
3.86
3.86
0.00
4.63
3.86
0.00
0.00
3.86
3.86
3.86
Load
301 Btuh
301 Btuh
0 Btuh
278 Btuh
935 Btuh
1017 Btuh
1160 Btuh
1253 Btuh
1203 Btuh
805 Btuh
521 Btuh
919 Btuh
0 Btuh
0 Btuh
326 Btuh
0 Btuh
702 Btuh
288 Btuh
0 Btuh
389 Btuh
301 Btuh
0 Btuh
0 Btuh
0 Btuh
0 Btuh
220 Btuh
0 Btuh
0 Btuh
0 Btuh
198 Btuh
237 Btuh
0 Btuh
0 Btuh
0 Btuh
0 Btuh
849 Btuh
1037 Btuh
885 Btuh
451 Btuh
0 Btuh
731 Btuh
100 Btuh
0 Btuh
0 Btuh
835 Btuh
528 Btuh
100 Btuh
Page 4
'all Total
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
-Int (0.124) MM0.0
- Ext (0.124) 3M0.0
- Ext (0.124) 3M0.0
- Ext (0.124) 3M0.0
EnergyGauge® / USRFZB v3.1
Page 5
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danes AC
Diamond Sands, FL Building Type: User
1214/2014
Doors
Type
Storm Ueff.
Area X
HTM=
Load
1
Wood - Exterior,
n
(0.460)
32
14.3
449 Btuh
2
Wood - Garage,
n
(0.460)
21
14.3
304 Btuh
3
Wood - Garage,
n
(0.460)
40
14.3
570 Btuh
4
Wood - Garage,
n
(0.460)
24
14.3
342 Btuh
5
Wood - Exterior,
n
(0.460)
28
14.3
399 Btuh
6
Wood - Exterior,
n
(0.460)
27
14.3
380 Btuh
7
Wood - Exterior,
n
(0.460)
21
14.3
304 Btuh
rinnr Tntal
193(saft)
2750Btuh
Ceilings
Type/Color/Surface
Ueff.
R-Value
Area X
HTM=
Load
1
Vented Attic/L/Metal
(0.032)
30.010.0
25
1.0
25 Btuh
2
Vented AtticftJMetal
(0.032)
30.010.0
360
1.0
355 Btuh
3
Vented Attic/L/Metal
(0.032)
30.0/0.0
854
1.0
843 Btuh
4
Vented Attic/L/Metal
(0.032)
30.0/0.0
237
1.0
234 Btuh
5
Vented Attic/L/Metal
(0.032)
30.0/0.0
212
1.0
209 Btuh
6
Vented Attic/L/Metal
(0.032)
30.0/0.0
25
1.0
25 Btuh
7
Vented Attic/L/Metal
(0.032)
30.010.0
40
1.0
39 Btuh
8
Vented Attic/UMetal
(0.032)
30.0/0.0
300
1.0
296 Btuh
9
Vented Attic/L/Metal
(0.032)
30.010.0
391
1.0
386 Btuh
10
Vented Attic/L/Metal
(0.032)
30.0/0.0
360
1.0
355 Btuh
11
Vented Attic/L/Metal
(0.032)
30.0/0.0
582
1.0
575 Btuh
12
Vented Attic/L/Metal
(0.032)
30.0/0.0
256
1.0
253 Btuh
13
Vented Attic/L/Metal
(0.032)
30.010.0
299
1.0
295 Btuh
14
Vented Attic/L/Metal
(0.032)
30.0/0.0
25
1.0
25 Btuh
15
Vented Attic/L/Metal
(0.032)
30.010.0
395
1.0
390 Btuh
16
Vented Attic/L/Metal
(0.032)
30.010.0
120
1.0
118 Btuh
17
Vented Attic/L/Metal
(0.032)
30.010.0
41
1.0
40 Btuh
18
Vented Attic/L/Metal
(0.032)
30.0/0.0
231
1.0
228 Btuh
19
Vented Attic/L/Metal
(0.032)
30.0/0.0
237
1.0
234 Btuh
20
Vented AtticlUMetal
(0.032)
30.010.0
225
1.0
222 Btuh
21
Vented Attic/L/Metal
(0.032)
30.010.0
225
1.0
222 Btuh
22
Vented Attic/L/Metal
(0.032)
30.0/0.0
60
1.0
59 Btuh
23
Vented Attic/L/Metal
(0.032)
30.0/0.0
347
1.0
343 Btuh
EnergyGauge® / USRFZB v3.1 Page 6
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
Floors
Type
Ueff.
R-Value
Size X HTM=
Load
1
Slab On Grade
(1.180)
0.0
20.0 ft(perim.)
36.6
732 Btuh
2
Slab On Grade
(1.180)
0.0
88.0 ft(perim.)
36.6
3219 Btuh
3
Raised Wood - Adj
(0.050)
19.0
854.0 sqft
1.6
1328 Btuh
4
Raised Wood - Adj
(0.050)
19.0
237.0 sqft
1.6
368 Btuh
5
Raised Wood - Adj
(0.050)
19.0
212.0 sqft
1.6
330 Btuh
6
Interior
(0.050)
0.0
25.0 sqft
0.0
0 Btuh
7
Raised Wood - Adj
(0.050)
19.0
40.0 sqft
1.6
62 Btuh
8
Raised Wood - Adj
(0.050)
19.0
300.0 sqft
1.6
466 Btuh
9
Raised Wood - Adj
(0.050)
19.0
391.0 sqft
1.6
608 Btuh
10
Interior
(0.050)
0.0
360.0 sqft
0.0
0 Btuh
11
Raised Wood - Adj
(0.050)
19.0
582.0 sgft
1.6
905 Btuh
12
Raised Wood - Adj
(0.050)
19.0
256.0 sqft
1.6
398 Btuh
13
Raised Wood - Adj
(0.050)
19.0
299.0 sqft
1.6
465 Btuh
14
Interior
(0.050)
0.0
25.0 sqft
0.0
0 Btuh
15
Interior
(0.050)
0.0
395.0 sqft
0.0
0 Btuh
16
Interior
(0.050)
0.0
120.0 sqft
0.0
0 Btuh
17
Interior
(0.050)
0.0
41.0 sqft
0.0
0 Btuh
18
Interior
(0.050)
0.0
231.0 sqft
0.0
0 Btuh
19
Interior
(0.050)
0.0
237.0 sqft
0.0
0 Btuh
20
Interior
(0.050)
0.0
225.0 sqft
0.0
0 Btuh
21
Interior
(0.050)
0.0
225.0 sqft
0.0
0 Btuh
22
Interior
(0.050)
0.0
347.0 sqft
0.0
0 Btuh
23
Interior
(0.050)
0.0
60.0 sqft
0.0
0 Btuh
Duct load
All Zones
Envelope Subtotal: 1 55228 Btuh
Type Wholehouse ACH Volume(cuff) Wall Ratio CFM=
Natural 0.50 74105 1.00 618.2 21064 Btuh
(DLM of Mixed ducts) 1 20178 Btuh
Sensible Subtotal All Zones 1 96471 Btuh
Subtotal Sensible Heat Loss 96471 Btuh
Totals for Heating Ventilation Sensible Heat Loss 0 Btuh
Total Heat Loss 96471 Btuh
EnergyGauge®! USRFZB v3.1
Page 7
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
1. Electric Strip Heat 49000 Btuh
2. Electric Strip Heat 49000 Btuh
3. Electric Strip Heat 49000 Btuh
Key: Window types -NFRC (Requires U-Factor and Shading coefficient(SHGC) of glass as numerical values)
or - Glass as'Clear' or Tint (Uses U-Factor and SHGC defaults)
U,- (Window.U-Factor)
HTM - (Manual] Heat Transfer Multiplier)
HBNI1641:
EnergyGauge® / USRFZB v3.1 Page 8
System Sizing Calculations a Summer
Residential Load - Whole House Component Details
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
Reference City: Fort Pierce, FL Temperature Difference: 15.OF(MJ8 99%) Humidity difference: 72gr.
EnergyGauge®! USRFZB v3.1 Page 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
Type Overhang WindowArea(sgft) HTM Load
VirdoW Panes SHGC U InSh IS Ornt Len H t .Gross ShadedUnshaded Shaded Unshaded_ _ _ _
__1.
'1 ' 2 NFRC 0.28, 0.31 No No W 2.Oft 2.Oft 44.0 0.0 44.0 11 32 1400 Btuh !
2 2 NFRC 0.28, 0.31 No No W 2.Oft 2.Oft 7.0 0.0 7.0 11 32 223 Btuh
'3 2 NFRC 0.28. 0.31 No No N 2.Oft 4.Oft 25.0 0.0 25.0 11 11 266 Btuh
4 2 NFRC 0.28, 0.31 No No N 2.Oft 4.Oft 25.0 0.0 25.0 1 11 11 266 Btuh
5 2 NFRC 0.28, 0.31 No No N 2.Oft 4.Oft 25.0 0.0 25.0 11 11 266 Btuh
6 2 NFRC 0.28, 0.31 No No N 2.Oft 4.Oft 8.0 0.0 8.0 11 11 85 Btuh
7 2 NFRC 0.28. 0.31 No No E 2.Oft 4.0ft 75.0 0.0 75.0 11 32 2387 Btuh
'8 :2 NFRC 0.28. 0.31 No No E 9.0@ 4.Oft 84.0 36.4 47.6 11 32 1901 Btuh
9 2 NFRC 0.28. 0.31 No No W 6.0ft 4.Oft 12.5 2.4 10.1 11 32 346 Btuh
10 2 NFRC 0.28, 0.31 No No W 2.Oft 4.011 25.0 0.0 25.0 11 32 796 Btuh
11 2 NFRC 0.28. 0.31 No No E 9.0ft 4.Oft 72.0 31.2 40.8 11 32 1630 Btuh
12 2 NFRC 0.28, 0.31 No No W 6.Oft 4.Oft 12.5 2.4 10.1 11 32 346 Btuh
13 2 NFRC 0.28, 0.31 No No W 6.Oft 4.Oft 32.0 3.9 28.1 11 32 935 Btuh
14 2 NFRC 0.28, 0.31 No No N • 2.Oft 5.Oft 13.5 0.0 13.5 11 11 144 Btuh
15 2 NFRC 0.28, 0.31 No No N 2.Oft 3.Oft 6.0 0.0 6.0 11 11 64 Btuh i
16 2 NFRC 0.28, 0.31 No No N 2.Oft 5.0ft 45.0 0.0 45.0 11 11 479 Btuh
17 2 NFRC 0.28. 0.31 No No N 2.Oft 3.0ft 20.0 0.0 20.0 11 11 213 Btuh
18 2 NFRC 0.28, 0.31 No No E 2.Oft 5.Oft 42.0 0.0 42.0 11 32 1336 Btuh
19 2 NFRC 0.28, 0.31 No No E 2.0ft 3.Oft 6.8 0.0 6.8 11 32 217 Btuh
20 2 NFRC 0.28, 0.31 No No E 2.Oft 5.Oft 24.0 0.0 24.0 11 32 764 Btuh
21 12 NFRC 0.28, 0.31 No No E 19.0f 3.Oft 110.0 110.0 0.0 11 32 1171 Stun
22 2 NFRC 0.28. 0.31 No No S 25.Of 3.Oft 50.0 50.0 0.0 11 12 532 Btuh
23 ! 2 NFRC 0.28, 0.31 No No S 25.Of 3.0ft 26.0 25.0 0.0 11 12 266 Btuh
24 2 NFRC 0.28, 0.31 No No W 6.Oft 5.Oft 15.0 0.0 MO 11 32 477 Btuh
25 2 NFRC 0.28. 0.31 No No W 6.0ft 3.Oft 1 6.0 5.9 0.1 11 32 65 Btuh
26 2 NFRC 0.28. 0.31 No No W 2.Oft 5.0ft 45.0 0.0 45.0 11 32 1432 Btuh
27 2 NFRC 0.28, 0.31 No No W 2.Oft 3.Oft 18.0 0.0 18.0 11 32 573 Btuh
28 2 NFRC 0.28, 0.31 No No W 2.0ft 10.Of 18.0 0.0 18.0 11 32 573 Btuh
29 2 NFRC 0.28, 0.31 No No W 2.Oft 5.Oft 11.3 0.0 11.3 11 32 358 Btuh
30 2 NFRC 0.28. 0.31 No No W 2.Oft 3.Oft 5.0 0.0 5.0 11 32 159 Btuh
31 2 NFRC 0.28. 0.31 No No E 19.Of 3.Oft 100.0 100.0 0.0 11 32 1064 Btuh
32 : 2 NFRC 0.28. 0.31 No No E 9.Oft 5.Oft 30.0 14.8 15.2 11 32 641 Btuh
33 2 NFRC 0.28. 0.31 No No E 9.0ft 3.Oft 6.0 6.0 0.0 11 32 64 Btuh
34 • 2 NFRC 0.28, 0.31 No No E 9.0ft 5.Oft 20.0 9.9 10.1 11 32 427 Btuh
35 12 NFRG 0.2e, 0.31 No No S 2.Oft 5.Oft 12.6 12.5 0.0 11 12 I 133 Stuh
36 2 NFRC 0.28. 0.31 No No S 2.0ft 3.Oft 5.0 5.0 0.0 11 12 53 Btuh
37 12 NFRC 0.28. 0.31 No No S 2.0ft 5.Oft 12.5 12.5 0.0 11 12 133 Btuh
38 2NFRC 0.28.0.31 No No S'2.Oft 3.0ft 5.0 5.0 0.0 11 12 53 Btuh
39 2 NFRC 0.28. 0.31 No No S 2.0ft 6.Oft • 20.0 20.0 0.0 11 12 213 Btuh
40 2 NFRC 0.28. 0.31 No No S 2.Oft 3.011 8.0 8.0 0.0 11 12 85 Btuh
41 2 NFRC 0.28, 0.31 No No S 2.Oft 5.Oft 25.0 25.0 0.0 11 12 266 Btuh
42 ; 2 NFRC 0.28, 0.31 No No S 2.Oft 3.0ft 10.0 10.0 0.0 11 12 106 Btuh
43 2 NFRC 0.28. 0.31 No No W 2.Oft 5.Oft 25.0 0.0 25.0 11 32 796 Btuh
44 2 NFRC 0.28, 0.31 No No W 2.Oft 3.Oft 10.0 0.0 10.0 11 32 318 Btuh
45 2 NFRC 0.28. 0.31 No No W 2.Oft 10.Of 10.0 0.0 10.0 11 32 318 Btuh
46 2 NFRC 0.28, 0.31 No No W 2.Oft 5.Oft 10.0 0.0 10.0 11 32 318 Btuh
47 12 NFRC 0.28, 0.31 No No W 2.Oft 3.Oft 5.0 0.0 5.0 1 11 32 159 Btuh
Window Total _ I_1222�sgft)._-.._ �. .._ __-1._ _ 2.4818 Btuh
EnergyGauge®1 USRFZB v3.1 Page 2
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danes AC
Diamond Sands, FL
12/4/2014
Walls
Type U-Value R-Value
Concrete Blk,Filled -Adj
Concrete Blk,Filled -Adj
Int
Concrete BlUilled -Adj
Concrete Blk,Filled - Ext
Concrete Blk,Filled -Adj
Concrete BIk,Filled -Adj
Concrete BIk,Filled -Adj
Concrete Blk,Filled - Ext
Concrete BlUilled - Ext
Concrete BIk,Fllled - Ext
Concrete Blk,Filied - Ext
Int
Int
Concrete BlUilled - Ext
- Int
Concrete Blk,Filled - Ext
Concrete Blk,Filled - Ext
- Int
Concrete Blk,Filled - Ext
Concrete BlUilled - Ext
- Int
- Int
- Int
- Int
Concrete BlUlIled - Ext
- Int
- Int
- Int
Concrete BlUilled - Ext
Concrete Blk,Filled - Ext
- Int
- Int
- Int
- Int
Concrete BlUilled - Ext
Concrete Blk,Filled - Ext
Concrete BIk,Fllled - Ext
Concrete BKFilled - Ext
- Int
Concrete BIk,Hollow- Ext
Concrete Blk,Filled - Ext
Int
Int
Concrete BlUilled - Fitt
Concrete Blk,Filled - Fitt
Concrete Blk,Fllled - Ext
- Int
Concrete Blk,Filled - Ext
- Int
Concrete BlUilled - Ext
Concrete Blk,Filled - Ext
Concrete BIk,Filled - Ext
Concrete BIk,Fllled - Ext
- Int
- Int
Concrete Blk,Fllled - Ext
Area(scift) HTM
Cav/Sheath
0.12
4.1/0.0
78.0
0.12
4.1/0.0
78.0
0.12
4.1/0.0
78.0
0.12
4.1/0.0
72.0
0.12
4.110.0
242.5
0.12
4.1/0.0
263.7
0.12
4.110.0
301.0
0.12
4.1/0.0
325.0
0.12
4.1/0.0
312.0
0.12
4.1/0.0
208.8
0.12
4.1/0.0
135.2
0.12
4.110.0
238.3
0.12
0.010.0
208.0
0.12
0.0/0.0
281.7
0.12
4.1/0.0
84.5
0.12
0.0/0.0
169.0
0.12
4.1/0.0
182.0
0.12
4.110.0
74.8
0.12
0.0/0.0
182.0
0.12
4.110.0
101.0
0.12
4.110.0
78.0
0.12
0.0/0.0
78.0
0.12
4.110.0
78.0
0.12
0.0/0.0
78.0
0.12
0.010.0
78.0
0.12
4.1/0.0
57.0
0.12
4.1/0.0
78.0
0.12
4.110.0
78.0
0.12
4.1/0.0
78.0
0.12
4.110.0
51.4
0.12
4.1/0.0
61.4
0.12
0.0/0.0
78.0
0.12
0.0/0.0
130.0
0.12
0.0/0.0
52.0
0.12
0.0/0.0
260.0
0.12
4.1/0.0
220.3
0.12
4.110.0
269.0
0.12
4.110.0
229.5
0.12
4.1/0.0
117.0
0.12
0.010.0
91.0
0.15
4.110.0
158.0
0.12
4.110.0
26.0
0.12
0.0/0.0
104.0
0.12
0.0/0.0
169.0
0.12
4.110.0
216.5
0.12
4.110.0
137.0
0.12
4.1/0.0
26.0
0.12
0.0/0.0
78.0
0.12
4.110.0
63.0
0.12
0.010.0
143.0
0.12
4.110.0
297.0
0.12
4.110.0
167.0
0.12
4.110.0
177.0
0.12
4.1/0.0
192.0
0.12
0.010.0
156.0
0.12
0.0/0.0
60.0
0.14=nergy GA@ / USRF 1343
1.9
1.9
0.0
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
0.0
0.0
1.9
0.0
1.9
1.9
0.0
1.9
1.9
0.0
0.0
0.0
0.0
1.9
0.0
0.0
0.0
1.9
1.9
0.0
0.0
0.0
0.0
1.9
1.9
1.9
1.9
0.0
2.2
1.9
0.0
0.0
1.9
1.9
1.9
0.0
1.9
0.0
1.9
1.9
1.9
1.9
0.0
0.0
1.9
Load
146 Btuh
146 Btuh
0 Btuh
134 Btuh
452 Btuh
492 Btuh
562 Btuh
606 Btuh
582 Btuh
390 Btuh
252 Btuh
445 Btuh
0 Btuh
0 Btuh
158 Btuh
0 Btuh
340 Btuh
139 Btuh
0 Btuh
188 Btuh
146 Btuh
0 Btuh
0 Btuh
0 Btuh
0 Stuh
106 Stuh
0 Btuh
0 Btuh
0 Btuh
96 Btuh
115 Btuh
0 Btuh
0 Btuh
0 Btuh
0 Btuh
411 Btuh
502 Btuh
428 Stuh
218 Btuh
0 Btuh
354 Stuh
49 Btuh
0 Btuh
0 Btuh
404 Btuh
256 Btuh
49 Btuh
0 Btuh
118 Btuh
0 Btuh
554 Btuh
312 Btuh
330 Btuh
350 Btuh
0 Btuh
0 Btuh
162 Btuhl
9996 Btuh
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danes AC
Diamond Sands, FL
12/4/2014
Doors
!Type
Area(sgft)
1
Wood - Exterior
31.5
2
Wood - Garage
21.3
3
Wood -Garage
40.0
4
Wood - Garage
24.0
5
Wood - Exterior
28.0
6
Wood - Exterior
26.7
7
Wood - Exterior
21.3
Door Total
193(sgft)
Ceilings
Type/Color/Surface
U-Value
R-Value
Area(sqft)
1
Vented AtticlUghtlMetal
0.032
30.010.0
25.0
'2
Vented AttiGLighVMetal
0.032
30.010.0
360.0
13
Vented AttiGLighVMetal
0.032
30.010.0
854.0
;4
Vented AttiGLighVMetal
0.032
30.0/0.0
237.0
5
Vented AtticfUghtlMetal
0.032
30.0/0.0
212.0
6
Vented AtUCJUght/Metal
0.032
30.010.0
25.0
7
Vented Attic(Ught/Metal
0.032
30.010.0
40.0
8
Vented AttiGLightMetal
0.032
30.0/0.0
300.0
9
Vented AttiGLighVMetal
0.032
30.010.0
391.0
�0
Vented AttiGLighVMetal
0.032
30.010.0
360.0
11
Vented Attic/Light/Metal
0.032
30.0/0.0
582.0
12
i Vented AtticlLightlMetal
0.032
30.0/0.0
256.0
13
! Vented AttiGLighVMetal
0.032
30.010.0
299.0
14
` Vented AttiAlght/Metal
0.032
30.0/0.0
25.0
15
Vented AHiGLightfMetal
0.032
30.0/0.0
395.0
d6
Vented AtdrjUght/Metal
0.032
30.010.0
120.0
�17
Vented Attic/Light/Metal
0.032
30.010.0
41.0
18
Vented AttiGLighVMetal
0.032
30.010.0
231.0
19
Vented AttiGLighVMetal
0.032
30.0/0.0
237.0
20
Vented AtticlUghtMetal
0.032
30.0f0.0
225.0
21
Vented AtticlUghtMetal
0.032
30.010.0
225.0
22
Vented Attic/Light/Metal
I
0.032
30.010.0
60.0
j23
Vented Attic/Light/Metal
0.032
30.010.0
347.0
ICeiling Total
_
5847 sgft) -_
HTM I Load
13.8
435
Btuh
13.8
294
Btuh
13.8
552
Btuh
13.8
331
Btuh
13.8
386
Btuh
13.8
368
Btuh
13.8
294
Btuh
_ 2861 Btuh
HTM Load -I
1.40 35 Btuh
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40 i
1.40
1.40
1.40
_:-l_
504 Btuh
1197 Btuh
332 Btuh
297 Btuh
35 Btuh
56 Btuh
420 Btuh
548 Btuh
504 Btuh
816 Btuh
359 Stuh
419 Btuh
35 Btuh
654 Btuh
168 Btuh
57 Btuh
324 Btuh
332 Btuh
315 Btuh
315 Btuh
84 Btuh
486 Btuh
8193 Btuh
EnergyGaugeV I USRFZB v3.1 Page 4
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124;S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
Floors
!Type
R-Value
Size
HTM
Load
1
Slab On Grade
0.0
25 (ft-perimeter)
0.0
0
Btuh
2
Slab On Grade
0.0
360 (ft-perimeter)
0.0
1
0
Btuh
3
Raised Wood -Adj
19.0
854 (sqft)
0.7
600
Btuh
4
Raised Wood -Adj
19.0
237 (sqft)
0.7
166
Btuh
5
Raised Wood -Adj
19.0
212 (sqft)
0.7
149
Btuh
6
Interior
0.0
25 (sqft)
0.0
0
Btuh
'7
18
Raised Wood -Adj
Raised Wood -Adj
19.0
19.0
40(sgft)
300 (sqft)
0.7
0.7
28
211
Btuh
Btuh
9
Raised Wood -Adj
19.0
391 (sqft)
0.7
275
Btuh
10
Interior
0.0
360 (sqft)
0.0
0
Btuh
11
Raised Wood -AdJ
19.0
582 (sgft)
0.7
409
Stun
12
Raised Wood -Adj
19.0
266 (sqft)
0.7
180
Btuh
13
Raised Wood -Adj
19.0
299 (sqft)
0.7
210
Btuh
14
Interior
0.0
25 (sqft)
0.0
0
Btuh
15
Anterior
0.0
395 (sqft)
0.0
0
Btuh
16
Interior
0.0
120 (sgft)
0.0
I
0
Btuh
17
Interior
0.0
41 (sqft)
0.0
0
Btuh
18
Interior
0.0
231 (sqft)
0.0
0
Btuh
19
Interior
0.0
237 (sqft)
0.0
0
Btuh
20
Interior
0.0
225 (sqft)
0.0
0
Stuh
21
Interior
0.0
225 (sqft)
0.0
1
0
Btuh
22
23
Interior
Interior
0.0
0.0
347 (sqft)
60 (sqft)
0.0
0.0
0
0
Stuh
Btuh
Floor Total
5847.0(sqft)
2226
Btuh
Envelope Subtotal:
47895
Btuh
Load
Infiltration I Type Average ACH Volume(cuft) Wall Ratio CFM=
jNatural
0.38
74105 1
463.7
7644
Stuh
Load
Internal Occupants Btuh/occupant Appliance
gain
19
X 230 +
5500
1
9870
Btuh
Sensible Envelope Load:
65409
Btuh
20955
Btuh
Duct load
_
(DGMs vary for Mixed ducts)
Sensible Load All Zones
86365 Btuh
EnergyGaugeO / USRFZB v3.1 Page 6
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
Sensible Envelope Load All Zones
6B035 Btuh
Sensible Duct Load
20955 Btuh
Total Sensible Zone Loads
88991 Btuh
Sensible ventilation
0 Btuh
Blower
147 Btuh
Whole House
Total sensible gain
89138 Btuh
Totals for Cooling
Latent infiltration gain (for 72 gr, humidity difference)
22683 Btuh
Latent ventilation gain
0 Btuh
Latent duct gain
9834 Btuh
Latent occupant gain (19.0 people @ 200 Btuh per person)
3800 Btuh
Latent other gain
0 Btuh
Latent total gain
36317 Btuh
TnVA1 f-AlAl
499MSS Rtllh
EQUIP,,MENT' `
1. Central Unit
#
48000 Btuh
2. Central Unit
#
48000 Btuh
3. Central Unit
#
48000 Btuh
*Key: Window types (Panes - Number and type of panes of glass)
(SHGC - Shading coefficient of glass as SHGC numerical value)
(U -Window U-Factor)
(InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R))
- For Blinds: Assume medium color, half closed
For Draperies: Assume medium weave, half closed
For Roller shades: Assume translucent, half dosed
(IS - Insect screen: none(N), Full(F) or Half(%))
(Ornt - compass orientation)
EnergyGaugeO / USRFZB v3.1 Page 6
System Sizing Calculations - Winter
Residential Load - Room by Room Component Details
8124 S. Ocean Drive
Diamond Sands, FL
Project Title:
Newman Residence Room by Room - Danas AC
Building Type: User
1214/2014
Reference City: Fort Pierce, FL (Defaults) Winter Temperature Difference: 31.0 F (MJ8 99%)
Com 'onent Lo_ ds for R#1 Elev aoom ator 1st Floor Zone 1- ;
Walls
Type Omt.
Leff.
R-Value
Area X HTM=
Load
(Cav/Sh)
1
Conc Blk, Filled -Adj
(0.124)
4.1/0.0
78 3.86
301 Btuh
2
Conc Blk, Filled -Adj
(0.124)
4.1/0.0
78 3.86
301 Btuh
3
- Int
(0.124)
4.110.0
78 0.00
0 Btuh
4
Conc Blk,Filled - Adj
(0.124)
4.1/0.0
72 3.86
278 Btuh
Wall Total
306 ft
879 Btuh
Ceilings
Type/Color/Surface
Leff.
R-Value
Area X HTM=
Load
1
Vented Attic/UMetal
(0.032)
30.0/0.0
25 1.0
25 Btuh
Ceiling Total
25 s ft
25Btuh
Floors
Type
Ueff.
R-Value
Size X HTM=
Load
1
Slab On Grade
(1.180)
0.0
20.0 ft(perim.) 36.6
732 Btuh
Floor Total
25 s ft
732 Btuh
Room Envelope Subtotal:
1635 Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural
0.50 325
0.03 20.9
713 Btuh
Duct load
Average sealed, Supply(RU-Attic), Retum(R6.0-Attic)
(DLM of 0.183)
430 Btuh
Room #1
Sensible Room Subtotal
2779 Btuh
r
Component Loads for Room #2
Foyer 1st Floor Zone 1
f
Window
Panes/Type
Frame U
Orientation Area s ft X
HTM=
Load
1
2, NFRC 0.28
Vinyl 0.31
W
44.0
9.6
423 Btuh
2
2, NFRC 0.28
Vinyl 0.31
W
7.0
9.6
67 Btuh
Window Total
51.0 s ft
490 Btuh
Walls
Type
Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
5
Conc Blk,Filled
- Ext (0.124)
4.110.0
243
3.86
935 Btuh
6
Conc Blk,Filled
-Adj (0.124)
4.1/0.0
264
3.86
1017 Btuh
7
Conc Blk,Filled
- Adj (0.124)
4.110.0
301
3.86
1160 Btuh
8
Conc Blk,Filled
-Adj (0.124)
4.110.0
325
3.86
1253 Btuh
Wall Total
1132 s ft
4365 Btuh
EnergyGauge® / USRFZB v3.1 Page 1
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124!S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
Doors
Type Storm Ueff,
Area -X
-HTM=
Load
1
Wood - Exterior, n
(0.460)
32
14.3
449 Btuh
2
Wood - Garage, n
(0.460)
21
14.3
304 Btuh
3
Wood - Garage, n
(0.460)
40
14.3
570 Btuh
4
Wood - Garage, n
(0.460)
24
14.3
342 Btuh
Door Total
117 s ft
1666Btuh
Ceilings
Type/Color/Surface
Ueff.
R-Value Area X
HTM=
Load
2
Vented Attic/UMetal
(0.032)
30.0/0.0 360
1.0
355 Btuh
Ceiling Total
360 s ft
355Btuh
Floors
Type
Ueff.
R-Value Size X
HTM=
Load
2
Slab On Grade
(1.180)
0.0 88.0 ft(perim.)
36.6
3219 Btuh
Floor Total
360 soft
3219]Btuh
Room Envelope Subtotal:
10096Infiltration
Type Wholehouse ACH Room Volume Wall RatioCFM=
Natural
0.50 4680 0.17
103.9
3541
DUCt IOad
Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic) (DLM of 0.183)
2499 Btuh
Room #2
Sensible Room Subtotal
18136 Btuh
Component;Loads for R66mrtF3 Kitctien,2nd Floor Rorie 7 r
' O
Window
Panesf-rvpe
Frame U
Orientation Area s ft X
HTM=
Load
16
2, NFRC 0.28
Vinyl 0.31
N
45.0
9.6
432 Btuh
17
2, NFRC 0.28
Vinyl 0.31
N
20.0
9.6
192 Btuh
18
2, NFRC 0.28
Vinyl 0.31
E
42.0
9.6
404 Btuh
19
2, NFRC 0.28
Vinyl 0.31
E
6.8
9.6
66 Btuh
20
2, NFRC 0.28
Vinyl 0.31
E
24.0
9.6
231 Btuh
22
2, NFRC 0.28
Vinyl 0.31
S
50.0
9.6
480 Btuh
23
2, NFRC 0.28
Vinyl 0.31
S
25.0
9.6
240 Btuh
Window Total
212.8 s ft
2045 Btuh
Walls
Type
Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
9
Conc Blk,Filled
- Ext (0.124)
4.1/0.0
312
3.86
1203 Btuh
10
Conc Blk,Filled
- Ext (0.124)
4.1/0.0
209
3.86
805 Btuh
11
Conc Blk,Filled
- Ext (0.124)
4.1/0.0
135
3.86
521 Btuh
12
Conc Blk,Filled
- Ext (0.124)
4.1/0.0
238
3.86
919 Btuh
13
- Int (0.124)
0.0/0.0
208
0.00
0 Btuh
14
- Int (0.124)
0.0/0.0
282
0.00
0 Btuh
Wall Total
1384 s ft
3448 Btuh
EnergyGaugeO / USRFZB v3.1 Page 2
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
Ceilings
Type/Color/Surface
Ueff. R-Value Area X
HTM=
Load
3
Vented Attic/L/Metal
(0.032) 30.0/0:0 854
1.0
843 Btuh
Floors
Ceiling Total
Type
854(sqft)
Ueff. R-Value Size X
HTM=
843Btuh
Load
3
Raised Wood - Adj
(0.050) 19.0 854.0 sqft
1.6
1328 Btuh
Floor Total
854 sqft
1328 Btuh
Room Envelope Subtotal:
7664 Btuh
InfilEload
Wholehouse ACH Room Volume Wall Ratio
CFM=
0.50 11102 0.13
82.1
2797 Btuh
Dupply(RG.0-Attic),
FAveragesealed,Retum(R6A-Attic) (DLM of
0.183)
1917 Btuh
Room #3
Sensible Room Subtotal
12379 Btuh
Component Loads forRoom #4 Prep„Room 2nd Floor Zone 1 t
A•i. Z rt
�
Window
Panes/Type
Frame U
Orientation Area(sqft) X
HTM=
Load
14
2, NFRC 0.28
Vinyl 0.31
N
13.5
9.6
130 Btuh
15
2, NFRC 0.28
Vinyl 0.31
N
6.0
9.6
58 Btuh
29
2, NFRC 0.28
Vinyl 0.31
W
11.3
9.6
108 Btuh
30
2, NFRC 0.26
Vinyl 0.31
W
5.0
9.6
48 Btuh
Window Total
35.8 s ft
344 Btuh
Wails
Type
Omt. Ueff,
R-Value
Area X
HTM=
Load
(Cav/Sh)
15
Conc Blk, Filled
- Ext (0.124)
4.1/0.0
85
3.86
326 Btuh
16
-Int (0,124)
0.0/0.0
169
0.00
0Btuh
17
' 18
Conc Blk,Filled
- Ext (0.124)
4.110.0
182
3.86
702 Btuh
Conc BIk,Filled
- Ext (0.124)
4.1/0.0
75
3.86
288 Btuh
19
- Int (0.124)
0.0/0.0
182
0.00
0 Btuh
Wall Total
692 s ft
1316 Btuh
Ceilings
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
4
Vented Aftic/L/Metal (0.032)
30.0/0.0
237
1.0
234 Btuh
Ceiling Total
237(sqft)
234Btuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
4
Raised Wood - Adj (0.050)
19.0
237.0 sqft
1.6
368 Btuh
Floor Total
237 sqft
368 Btuh
Room Envelope Subtotal:
2262 Btuh
EnergyGaugee / USRFZB v3.1 Page 3
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.50 3081 0.05 31.3
1067 Btuh
DUCt load
Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DLM of 0.183)
610 Btuh
Room #4
Sensible Room Subtotal
3939 Btuh
Window
Panes/Type
Frame U
Orientation Area s ft X
HTM=
Load
24
2, NFRC 0.28
Vinyl 0.31
W
15.0
9.6
144 Btuh
25
2, NFRC 0.28
Vinyl 0.31
W
6.0
9.6
58 Btuh
26
2, NFRC 0.28
Vinyl 0.31
W
45.0
9.6
432 Btuh
27
2, NFRC 0.28
Vinyl 0.31
W
18.0
9.6
173 Btuh
28
2, NFRC 0.28
Vinyl 0.31
W
18.0
9.6
173 Btuh
Window Total
102.0 s ft
980 Btuh
Walls
Type
Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
20
Conc Blk, Filled
- Ext (0.124)
4.1/0.0
101
3.86
389 Btuh
21
Conc Blk, Filled
- Ext (0.124)
4.1/0.0
78
3.86
301 Btuh
26
Conc Blk,Filled
- Ext (0.124)
4.1/0.0
57
3.86
220 Btuh
Wall Total
236 s ft
910 Btuh
Ceilings
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
5
Vented Attic/L/Metal (0.032)
30.010.0
212
1.0
209 Btuh
Ceilinq Total
212 s ft
2096tuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
5
Raised Wood - Adj (0.050)
19.0
212.0 sqft
1.6
330 Btuh
Floor Total
212 s ft
330 Btuh
Room Envelope Subtotal:
2429 Btuh
Infiltration
Type
Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50
2756
0.04
21.7
738 Btuh
Duct load
Average sealed, Supply(R6.0-Allic), Return(R6.0-Attic)
(DLM of 0.183)
580 Btuh
Room 05
Sensible Room Subtotal
3748 Btuh
EnergyGauge® I USRFZB v3.1 Page 4
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
•Walls
Type Ornt.
Ueff,
R-Value
Area X
HTM=
Load
(Cav/Sh)
27
Int
(0.124)
4.1/0.0
78
0.00
0 Btuh
28
- Int
'(0.124)
4.1/0.0
78
0.00
0 Stuh
29
- Int
(0.124)
4.1/0.0
78
0.00
0 Btuh
Wall Total
234 s ft
0 Btuh
Ceilings
Type/Color/Surface
Ueff.
R-Value
Area X
HTM=
Load
6
Vented Attic/L/Metal
(0.032)
30.0/0.0
25
1.0
25 Btuh
CeilingTotal
25 s ft
25Btuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
6
Interior
(0.050)
0.0
25.0 sqft
0.0
0 Btuh
Floor Total
25 sqft
0 Btuh
Room Envelope Subtotal:
25 Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50 325
0.00
0.0
0 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic)
(DLM of 0.183)
5 Btuh
Room #6
Sensible Room Subtotal
29 Btuh
». ,
Com onent Loads forjRooni #7 Powder Room 2nd FloorZomeF1 ;;'
P,... -
Walls
Type Ornt.
Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
22
-Int
(0.124)
0.0/0.0
78
0.00
0 Btuh
23
- Int
(0.124)
4.1/0.0
78
0.00
0 Btuh
24
-Int
(0.124)
0.0/0.0
78
0.00
0 Btuh
25
-Int
(0.124)
0.0/0.0
78
0.00
0 Btuh
Wall Total
312 s ft
0 Btuh
Ceilings
Type/Color/Surface
Ueff.
R-Value
Area X
HTM=
Load
7
Vented Attic/UMetal
(0.032)
30.0/0.0
40
1.0
39 Btuh
CeilingTotal
40 s ft
396tuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
7
Raised Wood - Adj
(0.050)
19.0
40.0 sqft
1.6
62 Btuh
Floor Total
40 sqft
62 Btuh
Room Envelope Subtotal:
102 Btuh
EnergyGaugee / USRFZB v3.1 Page 5
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124, S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.50 520 0.00 0.0
0 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DLM of 0,183)
19 Btuh
Room #7
Sensible Room Subtotal
120 Btuh
Window
anes[Type Frame U
Orientation Area s ft X
HTM=
Load
21
2, NFRC 0.28 Vinyl 0.31
E
110.0
9.6
1057 Btuh
Window Total
110.0 s ft
1057 Btuh
Walls
Type Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
30
Conc BIk,Filled - Ext (0.124)
4.1/0.0
51
3.86
198 Btuh
Wall Total
51 s ft
198 Btuh
Ceilings
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
8
Vented Attic/L/Metal (0.032)
30.0/0.0
300
1.0
296 Btuh
Ceilino Total
300 s ft
29613tuh
Floors
Type Ueff.
R-Value
Size X
HTM=
Load
8
Raised Wood - Adj (0.050)
19.0
300.0 sqft
1.6
466 Stuh
Floor Total
300 scift
466 Btuh
Room Envelope
Subtotal:
2018 Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural 0.50 3900
0.01
4.7
161 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic)
(DLM of 0.183)
399 Btuh
Room #8
Sensible Room Subtotal
2578 Stuh
Component Loads for Room #9 S Sti'of Lrvmg-2nd Floor Zn
Window
Panes/T a Frame
U Orientation Area s ft X HTM=
Load
31
2, NFRC 0.28 Vinyl
Window Total
0.31 E 100.0 9.6
100.0 s ft
961 Btuh
961 Btuh
EnergyGaugeV I USRFZB v3.1 Page 6
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
Walls
Type Ornt
Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
31
Conc BIk,Filled - Ext
(0.124)
4.1/0.0
61
3.86
237 Btuh
32
-Int
(0.124)
0.010.0
78
0.00
0Btuh
33
- Int
(0.124)
0.010.0
130
0.00
0 Btuh
34
- Int
(0.124)
0.0/0.0
52
0.00
0 Btuh
35
- Int
(0.124)
0.0/0.0
260
0.00
0 Btuh
Wall Total
581 s ft
237 Btuh
Ceilings
Type/Color/Surface
Ueff.
R-Value
Area X
HTM=
Load
9
Vented Attic/L/Metal
(0.032)
30.010.0
391
1.0
386 Btuh
Ceiling Total
391 (sqft)
385Btuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
9
Raised Wood - Adj
(0.050)
19.0
391.0 sqft
1.6
608 Btuh
Floor Total
391 scift
608 Btuh
Room Envelope Subtotal:
2192 Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50 5083
0.01
5.6
192 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Return(136.4Atdc)
(DLM of 0.338)
806 Btuh
Room #9
Sensible Room Subtotal
3190 Btuh
Walls
Type Ornt.
Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
51
Conc Blk, Filled - Fact
(0.124)
4.1/0.0
297
3.86
1145 Btuh
Wall Total
297 s ft
1145 Btuh
Doors
Type Storm Ueff.
Area X
HTM=
Load
5
Wood - Exterior, n
(0.460)
28
14.3
399 Btuh
Door Total
28 s ft
399Btuh
Ceilings
Type/Color/Surface
Ueff.
R-Value
Area X
HTM=
Load
10
Vented Aftic/UMetal
(0.032)
30.0/0.0
360
1.0
355 Btuh
Ceiling Total
360(sqft)
35513tuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
10
Interior
(0.050)
0.0
360.0 sqft
0.0
0 Btuh
Floor Total
360 sqft
0 Btuh
Room Envelope Subtotal:
1900 Btuh
EnergyGauge® / USRFZB 0.1 Page 7
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
1214/2014
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.50 4680 0.04 27.3
929 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic) (DLM of 0.338)
957 Btuh
Room #10
Sensible Room Subtotal
3785 Btuh
Como: nent o._. s oRoom #.1. 1 Ms�t..'r.
tip
Window
PanesrFype
Frame U
Orientation Area s ft X
HTM=
Load
32
2, NFRC 0.28
Vinyl 0.31
E
30.0
9.6
288 Btuh
33
2, NFRC 0.28
Vinyl 0.31
E
6.0
9.6
58 Btuh
34
2, NFRC 0.28
Vinyl 0.31
E
20.0
9.6
192 Btuh
35
2, NFRC 0.28
Vinyl 0.31
S
12.5
9.6
120 Btuh
36
2, NFRC 0.28
Vinyl 0.31
S
5.0
9.6
48 Btuh
Window Total
73.5 s ft
706 Btuh
Walls
Type
Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
36
Conc Blk,Filled
- Ext (0.124)
4.110.0
220
3.86
849 Btuh
37
Conc Blk,Filled
- Ext (0.124)
4.110.0
269
3.86
1037 Btuh
38
Conc Blk,Filled
- Ext (0.124)
4.110.0
230
3.86
885 Btuh
39
Conc Blk,Filled
-Ext (0.124)
4.1/0.0
117
3.86
451 Btuh
40
- Int (0.124)
0.0/0.0
91
0.00
0 Btuh
43
- Int (0.124)
0.0/0.0
104
0.00
0 Btuh
Wall Total
1031 s ft
3222 Btuh
doors
Type
Storm Ueff.
Area X
HTM=
Load
6
Wood - Exterior,
n (0.460)
27
14.3
380 Btuh
Door Total
27 s ft
3806tuh
Celungs
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
11
Vented Attic/L/Metal (0.032)
30.0/0.0
582
1.0
575 Stuh
Ceiling Total
582 s ft
5758tuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
11
Raised Wood - Adj (0.050)
19.0
582.0 sqft
1.6
905 Btuh
Floor Total
582 s ft
905 Btuh
Room Envelope Subtotal:
5788 Btuh
Infiltration
Type
Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50
7566
0.12
76.7
2614 Btuh
Duct load
Average sealed, Supply(R(3.0-Attic), Retum(R6.0-Attic)
(DLM of 0.338)
2842 Btuh
EnergyGauge® I USRFZB v3.1 Page 8
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124' S. Ocean Drive Newman Residence Room by Room - Danes AC
Diamond Sands, FL Building Type: User
12/4/2014
Room #11 Sensible Room Subtotal T
11244 Btuh
Window
Panes/Type Frame
U
Orientation Area s ft X
HTM=
Load
39
2, NFRC 0.28 Vinyl 0.31
S
20.0
9.6
192 Btuh
40
2, NFRC 0.28 Vinyl 0.31
S
8.0
9.6
77 Btuh
41
2, NFRC 0.28 Vinyl 0.31
S
25.0
9.6
240 Btuh
42
2, NFRC 0.28 Vinyl 0.31
S
10.0
9.6
95 Btuh
Window Total
63.0 s ft
605 Btuh
Walls
Type Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
41
Conc Blk,Hollow - Ext (0.149)
4.110.0
158
4.63
731 Btuh
42
Conc Blk,Filled - Ext (0.124)
4.1/0.0
26
3.86
100 Btuh
44
- Int (0.124)
0.0/0.0
169
0.00
0 Btuh
Wall Total
353 s ft
831 Btuh
Ceilings
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
12
Vented Attic/L/Metal (0.032)
30.0/0.0
256
1.0
253 Btuh
Ceiling Total
256 s ft
25313tuh
Floors
Type Ueff.
R-Value
Size X
HTM=
Load
12
Raised Wood - Adj (0.050)
19.0
255.0 sqft
1.6
398 Stuh
Floor Total
256 s ft
398 Btuh
Room Envelope Subtotal:
2087 Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural 0.50 3328
0.03
16.9
576 Btuh
Duct load
Average sealed, Supply(Rfl.0-Attic), Retum(Ra.0-Aftic)
(DLM of
0.338)
901 Btuh
Room #12
Sensible Room Subtotal
3563 Btuh
EnergyGauge® / USRFZB v3.1 Page 9
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
Component Loads for;Room #13 �Sfudio ' . F ;. ` '1 ,z ` r c '
Window
PanesfType
Frame U
Orientation Area s R X
HTM=
Load
37
2, NFRC 0.28
Vinyl 0.31
S
12.5
9.6
120 Btuh
38
2, NFRC 0.28
Vinyl 0.31
S
5.0
9.6
48 Btuh
43
2, NFRC 0.28
Vinyl 0.31
W
25.0
9.6
240 Btuh
44
2, NFRC 0.28
Vinyl 0.31
W
10.0
9.6
96 Btuh
45
2, NFRC 0.28
Vinyl 0.31
W
10.0
9.6
96 Btuh
46
2, NFRC 0.28
Vinyl 0.31
W
10.0
9.6
96 Btuh
47
2, NFRC 0.28
Vinyl 0.31
W
5.0
9.6
48 Btuh
Window Total
77.5 s ft
745 Btuh
Walls
Type
Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
45
Conc Blk, Filled
- Ext (0.124)
4.1/0.0
217
3.86
835 Btuh
46
Conc BIk,Filled
- Ext (0,124)
4.110.0
137
3.86
628 Btuh
47
Conc Blk, Filled
- Ext (0.124)
4.1/0.0
26
3.86
100 Btuh
48
- Int (0.124)
0.0/0.0
78
0.00
0 Btuh
49
Conc Blk,Filled
- Ext (0.124)
4.1/0.0
63
3.86
243 Btuh
50
- Int (0.124)
0.0/0.0
143
0.00
0 Btuh
Wall Total
664 s ft
1706 Btuh
Ceilings
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
13
Vented Attic/L/Metal (0.032)
30.010.0
299
1.0
295 Btuh
Ceiling Total
299 s ft
295Btuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
13
Raised Wood - Adj (0.050)
19.0
299.0 sgft
1.6
465 Btuh
Floor Total
299 s ft
465 Btuh
Room Envelope Subtotal:
3211 Btuh
Infiltration
Type
Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50
3887
0.07
40.6
1384 Btuh
Duct load
Average sealed, Supply(R6.0-Auic), Retum(R6.0-Attic)
(DLM of
0.338)
1554 Btuh
Room #13
Sensible Room Subtotal
6149 Btuh
Walls
Type
Omt.
Ueff.
R-Value Area X
HTM=
Load
(Cav/Sh)
67
-Int
(0.124)
4.110.0 72
0.00
0 Btuh
68
- Int
(0.124)
4.1/0.0 72
0.00
0 Btuh
69
- Int
(0.124)
4.1/0.0 72
0.00
0 Btuh
Wall Total
Ener
Gau ee I USRFZB v3. 5 ft
0 Btuh
Page 10
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124, S. Ocean Drive Newman Residence Room by Room - Danes AC
Diamond Sands, FL Building Type: User
1214l2014
Ceilings
Type/Color/Surface Ueff. R-Value Area X HTM=
Load
14
Vented Attic/L/Metal (0.032) 30.0/0.0 25 1.0
25 Btuh
Ceilinq Total 25 s ft
2513tuh
Floors
Type Ueff. R-Value Size X HTM=
Load
14
Interior (0.050) 0.0 25.0 sgft 0.0
0 Btuh
Floor Total 25 s ft
0 Btuh
Room Envelope Subtotal:
25 Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.50 300 0.00 0.0
0 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic) (DLM of 0.330)
8 Btuh
Room #14
Sensible Room Subtotal
33 Btuh
Window
Panes/Type
Frame U
Orientation Area s ft X
HTM=
Load
3
2, NFRC 0.28
Vinyl 0.31
N
25.0
9.6
240 Btuh
7
2, NFRC 0.28
Vinyl 0.31
E
75.0
9.6
721 Btuh
Window Total
100.0 s ft
961 Btuh
Walls
Type
Ornt. Ueff,
R-Value
Area X
HTM=
Load
(Cav/Sh)
52
Conc Blk, Filled
- Ext (0.124)
4.1/0.0
167
3.86
644 Btuh
53
Conc Blk, Filled
- Ext (0.124)
4.110.0
177
3.86
682 Btuh
54
Conc Blk, Filled
- Ext (0.124)
4.1/0.0
192
3.86
740 Btuh
55
- Int (0.124)
0.0/0.0
156
0.00
0 Btuh
56
- Int (0.124)
0.010.0
60
0.00
0 Btuh
Wall Total
752 s ft
2066 Btuh
Ceilings
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
15
Vented Attic/L /Metal (0.032)
30.0/0.0
395
1.0
390 Btuh
Ceiling Total
395 s ft
3908tuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
15
Interior
(0.050)
0.0
395.0 sqft
0.0
0 Btuh
Floor Total
395 s ft
0 Btuh
Room Envelope Subtotal:
3417 Btuh
Infiltration
Type
Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50 4740
0.08
49.2
1677 Btuh
EnergyGauge®! USRFZB 0.1 page 11
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
Duct load
Average sealed, Supply(116.0-Attic), Return(R6.0-Attic) (DLM of 0.330)
1682 Btuh
Room #15
Sensible Room Subtotal
6776 Btuh
Window
Panes/Type
Frame U
Orientation Area s ft X
HTM=
Load
5
2, NFRC 0.28
Vinyl 0.31
N
25.0
9.6
240 Btuh
6
2, NFRC 0.28
Vinyl 0.31
N
8.0
9.6
77 Btuh
Window Total
33.0 s ft
317 Btuh
Walls
Type
Ornt. Leff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
57
Conc Blk,Filled
- Ext (0.124)
4.1/0.0
87
3.86
335 Btuh
58
- Int (0.124)
0.0/0.0
120
0.00
0 Btuh
59
- Int (0.124)
0.0/0.0
144
0.00
0 Btuh
Wall Total
351 s ft
335 Btuh
Ceilings
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
16
Vented Attic/UMetal (0.032)
30.0/0.0
120
1.0
118 Btuh
Ceilinq Total
1qn(Qnfn
118Btuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
16
Interior
(0.050)
0.0
120.0 sqft
0.0
0 Btuh
Floor Total
120 s ft
0 Btuh
Room Envelope Subtotal:
771 Btuh
Infiltration
Type
Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50
1440
0.01
8.0
272 Btuh
Duct load
Average sealed, Supply(116.0-Attic), Return(R6.0-AtLc)
(DLM of 0.330)
344 Btuh
Room #16
Sensible Room Subtotal
1388 Btuh
ComponentLo'a'dsfor,Room`#1T VIPWIC`3rd'FloorZone`3 r= ... yx
Walls
Type Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
89
- Int (0.124)
0.0/0.0
120
0.00
0 Btuh
Wall Total
120 s ft
0 Btuh
Energy0auge® / USRFZB v3.1 Page 12
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danes AC
Diamond Sands, FL Building Type: User
1214/2014
Ceilings
Type/Color/Surface Ueff. R-Value Area X HTM=
Load
17
Vented Attic/UMetal (0.032) 30.0/0.0 41 1.0
40 Btuh
Ceiling Total 41 s ft
4013tuh
Floors
Type Ueff. R-Value Size X HTM=
Load
17
Interior (0.050) 0.0 41.0 sgft 0.0
0 Btuh
Floor Total 41 s ft
0 Btuh
Room Envelope Subtotal:
40 Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.50 492 0.00 0.0
0 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DLM of 0.330)
13 Btuh
Room #17
Sensible Room Subtotal
54 Btuh
Ceilings
Type/Color/Surface Ueff. R-Value Area X HTM=
Load
18
Vented Attic/UMetal (0.032) 30.010.0 231 1.0
228 Btuh
Ceiling Total 231 (qnffl
228Btuh
Floors
Type Ueff. R-Value Size X HTM=
Load
18
Interior (0.050) 0.0 231.0 sgft 0.0
0 Btuh
Floor Total 231 s ft
0 Btuh
Room Envelope Subtotal:
228Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.50 2772 0.00 0.0
0 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DLM of 0.330)
75 Btuh
Room #18
Sensible Room Subtotal
303 Btuh
EnergyGauge® I USRFZB v3.1 Page 13
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danes AC
Diamond Sands, FL Building Type: User
12/4/2014
Window
Panes/Type
Frame U
Orientation Area s ft X
HTM=
Load
4
2, NFRC 0.28
Vinyl 0.31
N
26.0
.9.6
240 Btuh
10
2, NFRC 0.28
Vinyl 0.31
W
25.0
9.6
240 Btuh
Window Total
50:0 s ft
480 Btuh
Walls
Type
Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
60
Conc Blk,Filled
- Ext (0.124)
4.110.0
60
3.86
231 Btuh
1 61
- Int (0.124)
0.010.0
60
0.00
0 Btuh
62
Conc Blk,Filled
- Ext (0.124)
4.110.0
143
3.86
551 Btuh
63
Conc Blk,Filled
- Ext (0.124)
4.1/0.0
227
3.86
875 Btuh
64
Int (0.124)
0.0/0.0
108
0.00
0 Btuh
65
Int (0.124)
0.0/0.0
96
0.00
0 Btuh
66
Int (0.124)
4.1/0.0
72
0.00
0 Btuh
Wall Total
766 s ft
1658 Btuh
Ceilings
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
1 19
Vented Aftic/L/Metal (0.032)
30.0/0.0
237
1.0
234 Btuh
I
Ceiling Total
237 s ft
234Btuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
19
interior
(0.050)
0.0
237.0 sqft
0.0
0 Btuh
Floor Total
237 s ft
0 Btuh
I
Room Envelope Subtotal:
2372 Btuh
Infiltration
Type
Wholehouse ACH Room Volume
Wall Ratio
CFM=
Natural
0.50
2844
0.06
39.5
1345 Btuh
Duct
i
load
Average sealed, Supply(116.0•Attic), Retum(R6.0-Attic)
(DLM of 0.330)
1227 Btuh
Room
#19
Sensible Room Subtotal
4944 Btuh
Window
I Panesrrvpe Frame U Orientation Area s ft X HTM=
Load
8
2, NFRC 0:28 Vinyl 0.31 E 84.1 9.6
Window Total 84.1 s ft
807 Btuh
807 Btuh
EnergyGaugeOI USRFZB v3.1 Page 14
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124,S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User 12/4/2014
Walls
Type Omt.
Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
S2
- Int
(0.124)
0.010.0
96
0.00
0 Btuh
83
- Int
(0.124)
0.0/0.0
60
0.00
0 Btuh
84
- Int
(0.124)
0.010.0
120
0.00
0 Btuh
85
Conc Blk,Fiiled - Ext
(0.124)
4.1/0.0
72
3.86
278 Btuh
88
- Int
(0.124)
0.0/0.0
84
0.00
0 Btuh
87
- Int
(0.124)
0.0/0.0
96
0.00
0 Btuh
88
- Int
(0.124)
0.010.0
48
0.00
0 Btuh
Wall Total
576 s ft
278 Btuh
Ceilings
Type/Color/Surface
Ueff.
R-Value
Area X
HTM=
Load
20
Vented Attic/L/Metal
(0.032)
30.0/0.0
225
1.0
222 Btuh
Ceiling Total
225 s ft
22213tuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
20
Interior
(0.050)
0.0
225.0 scift
0.0
0 Btuh
Floor Total
225 s ft
0 Btuh
Room Envelope Subtotal:
1307 Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50 2700
0.01
6.6
225 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic)
(DLM of 0.330)
506 Btuh
Room #20
Sensible Room Subtotal
2038 Btuh
Component Loads for�Room #2f Bed 4 3rd Floor 2ona 3'
y
Window
Panes/Tv a
Frame U
Orientation Area s ft X
HTM=
Load
11
2, NFRC 0.28
Vinyl
0.31
E
72.0
9.6
692 Btuh
Window Total
72.0 s ft
692 Btuh
Wails
Type
Omt.
Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
77
Conc Blk, Filled
- Ext
(0.124)
4.110.0
108
3.86
Btuh
78
Conc Blk,Filled
- Ext
(0.124)
4.110.0
156
3.86
6 01 Btuh
01
79
Conc Blk, Filled
- Ext
(0.124)
4.110.0
84
3.86
324 Btuh
80
- Int
(0.124)
0.010.0
144
0.00
0 Btuh
81
- Int
(0.124)
0.010.0
96
0.00
0 Btuh
Wall Total
588 s ft
1342 Btuh
Ceilings
Type/Color/Surface
Ueff.
R-Value
Area X
HTM=
Load
21
Vented Attic/UMetal (0.032)
30.0/0.0
225
1.0
222 Btuh
Ceiling Total
225 s ft
222Btuh
EnergyGauge® I USRFZB v3.1 Page 15
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124! S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
12/4/2014
Floors
21
Type Ueff. R-Value Size X HTM=
Interior (0.050) 0.0 225.0 sqft 0.0
Floor Total 225 s ft
Load
0 Btuh
0 Btuh
Room Envelope Subtotal:
2256 Btuh
Infiltration
Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.50 2700 0.05 31.9
1088 Btuh
Duct load
Average sealed, Supply(R6.0-At9c), Return(R6.0-Attic) (DLM of 0.330)
1104 Btuh
Room #21
Sensible Room Subtotal
4448 Btuh
Component
Loads for Room #22
Lounge 3rd:Floor Zone 3 v
Window
Panes/TVpe
Frame U
Orientation Area s ft X
HTM=
Load
12
2, NFRC 0.28
Vinyl 0.31
W
12.5
9.6
120 Btuh
13
2, NFRC 0.28
Vinyl 0.31
W
32.0
9.6
308 Btuh
Window Total
44.5 s ft
428 Btuh
Walls
Type
Ornt. Ueff.
R-Value
Area X
HTM=
Load
(Cav/Sh)
73
Conc Blk,Filled
- Ext (0.124)
4.110.0
162
3.86
625 Btuh
74
Conc Blk,Filled
- Ext (0.124)
4.1/0.0
204
3.86
786 Btuh
75
- Int (0.124)
0.0/0.0
96
0.00
0 Btuh
76
-Int (0.124)
0.0/0.0
60
0.00
0Btuh
Wall Total
522(saftl
1412 Btuh
Doors
Type
Storm Ueff.
Area X
HTM=
Load
7
Wood - Exterior,
n (0.460)
21
14.3
304 Btuh
Door Total
21 s ft
30413tuh
Ceilings
Type/Color/Surface Ueff.
R-Value
Area X
HTM=
Load
23
Vented Attic/L/Metal (0.032)
30.010.0
347
1.0
343 Btuh
Ceilinq Total
347 s ft
343Btuh
Floors
Type
Ueff.
R-Value
Size X
HTM=
Load
22
Interior
(0.050)
0.0
347.0 sgft
0.0
0 Btuh
Floor Total
347soft
0Btuh
Room Envelope Subtotal:
2486 Btuh
Infiltration
Type
Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50
4164
0.05
33.6
1145 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic)
(DLM of 0.330)
1199 Btuh
EnerqvGauqe@!
USRFZB v3.1
Page 16
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danes AC
Diamond Sands, FL Building Type: User
12/4/2014
Room #22E- Sensible Room Subtotal 4830 Btuh
au
Loads for Room #23 Utili 3rd Floor Zone
Compogent
Window
Panes/Tvpe
Frame U Orientation Area s ft X
HTM=
Load
9
2, NFRC 0.28
Vinyl 0.31 W 12.5
9.6
120 Btuh
Window Total
12.5 s ft
120 Btuh
Walls
Type
Ornt. Leff. R-Value Area X
HTM=
Load .
(Cav/Sh)
70
Conc Blk,Filled
- Ext (0.124) 4.1/0.0 132
3.86
509 Btuh
71
Conc Blk,Filled
- Ext (0.124) 4.110.0 60
3.86
229 Btuh
72
-'Int (0.124) 0.0/0.0 132
0.00
0 Btuh
Wall Total
324 s ft
738 Btuh
Ceilings
Type/Color/Surface Ueff. R-Value Area X
HTM=
Load
22
Vented Attic/L/Metal (0.032) 30.0/0.0 60
1.0
59 Btuh
Ceiling Total
60 s ft
59Btuh
Floors
Type
Ueff. R-Value Size X
HTM=
Load
23
Interior
(0.050) 0.0 60.0 sqft
0.0
0 Stuh
Floor Total
60 soft
0 Btuh
Room Envelope Subtotal:
918 Btuh
Infiltration
Type
Wholehouse ACH Room Volume Wall Ratio
CFM=
Natural
0.50 720 0.03
17.6
599 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DLM of 0.330)
501 Stuh
Room #23
Sensible Room Subtotal
2017 Btuh
Heating Loads
For System(s):1 Block load 41708 Btuh
Serving Rooms: 1, 2, 3, 4, 5 6, 7, 8
EnergyGauge®/ USRFZB 0.1 Page 17
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL Building Type: User
1214/2014
Heating Loads
For System(s):2 Block load 27932 Btuh
Serving Rooms: 9, 10, 11, 12. 13
Heating Loads
ForSystem(s):3 Block load 26831 Btuh
Serving Rooms: 14, 15, 16, 17, 18, 19, 20, 21, 22, 23
Subtotal Sensible Heat Loss 96471 Btuh
Totals for Heating Ventilation Sensible Heat Loss 0 Btuh
Total Heat Loss 96471 Btuh
1. Electric Strip Heat 49000 Btuh
2. Electric Strip Heat 49000 Btuh
3. Electric Strip Heat 49000 Btuh
Key: Window types -NFRC (Requires U-Factor and Shading coefacient(SHGC) of glass as numerical values)
or- Glass as'Cleae or Tint' (Uses U-Factor and SHGC defaults)
U - (Window U-Factor)
HTM - (ManuaU Heat Transfer Multiplier)
EnergyGauge® / USRFZB v3.1 Page 18
System Sizing Calculations - Summer
Residential Load - Room by Room Component Details
Project Title:
8124iS. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
1214/2014
Reference City: Fort Pierce, FL
Temperature Difference: 15.OF(MJ8 99%) Humidity difference: 72gr.
Component Loads 'lb ';Eleiat6
Floor
Walls
Tip-- ---
11
Concrete Bik,Filled -Adi
i Concrete Blk,Filled - Adj
12
3
- Int
4
Concrete Blk,Filled - Adi
Wall Total
Vented AtticfLight/Metal
Ceilin Total
Type
Stab On Grade
u-Value -- ' ue R--Value Area(s4m
CaviSheath
0.12
4.110.0
78.0
0.12
4.1/0.0
78.0
0.12
4.1/0.0
78.0
0.12
4.1/0.0
72.0
.. ........ �-VaW R-Value- kea(s
6.032 30.0/0.0 25.6
25
HTMI-Load - -
1.9
14
Btuh
1.9
146
t.h
0.0
0
Btuh
1.9
134
Btuh
425
Btuh
IT-10-2
Load
1.40 35 Btuh
:1 1 35 Btuh
R-Value Size HTM
0.0 25 (ft-perimeter) 0.0
.25-0
Zone Envelope
I
Infiltration, Type Wholehouse ACH Volume(cuft) Wall Ratio CFM=
Natural 0.38 325 0.03 15.7
Intbrnal Occupants Btuh/occupant Applianc
gam 1 X 230 + 0
Sensible Envelope Load:
'DLtq .,_t.load Average sealed,
0 Btuh
0 Btuh
460 Btuh
Load
259 Btul
Load
230 - Btul
949 Btuh
@M of 0-207) 196 Btuh
Sensible Zone Load 1 1145 Btuh
fywe
-Overhang
Window
Are-a(scot)
HTM
Window
Panes SHGC U InSh
13 Ornt Len
Hgt
Gross Shaded Unshaded Shaded Unshaded
1
2 NFRC 0.28, 0.31 No
NOW
Oft
44.0
0.0 44.0 11
32
2
2 NFRC 0.28, 0.31 No
No W 2.Oft
2.Oft
7,0
0.0 7.0 it
32
Window Total
51 (sqft)
Walls
Type
U-Value
R-Value
Area(sqft)
HTM
Cav/Sheath
5
Concrete Blk,Filled - Ext
0.12
4.1/0.0
242.5
1.9
6
Concrete Blk,Filled - Adi
0.12
4.1/0.0
263.7
1.9
7
Concrete Bik,Filled - Adj
0.12
4.110.0
301.0
1.9
a
Concrete 81k,Filled - Adj
0.12
4.110.0
325.0
1.9
_ _LWaIll
Total
113.2
Load
1400 Btuh
223 Btuh
1623 Btuh
Load
452 Btuh
492 Btuh
562 Btuh
606 Btuh
2112 Btuh
EnergyG2ugeO I USRFZB v3.1 Page 1
Manual J Summer Calculations
Residential
Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124-S. Ocean Drive
Newman Residence Room by Room - Danes AC
Diamond Sands, FL
12/4/2014
Doors Type
Area (sqft) HTM
Load
1 Wood - Exterior
31.5 13.8
435 Btuh
2 Wood - Garage
21.3 13.8
294 Btuh
3 Wood - Garage
40.0 13.8
552 Btuh
4 Wood -Garage
24.0 13.8
331 Btuh
Door Total
117 (sgft) -... --
1612 Btuh
----
Ceilings Type/Color/Surface
- --- -- -
0-Value R-Value Area(sgft) HTM
Load
.I 2 Vented AUWI-Ight/Metal
0.032 30.0/0.0 360.0 1.40
504 Btuh
Ceiling Total
- - 360 (sgft) --- --- - _ ._
504 Btuh
y
_....
Floors Type
_ - --
R-Value Size HTM
Load
2 Slab On Grade
0.0 360 (ft-pedmeter) 0.0
0 Btuh
Floor Total
360.0 (sgft)_
0 Btuh
_
Zone Envelope Subtotal:
5852 Btuh
Infiltration; Type
Wholehouse ACH Volume(cuft) Wall Ratio CFM=
Load
Natural
0.38 4680 0.17 77.9
1285 Btuh
Internal i
Occupants Btuh/occupant Appliance
Load
gain
1 X 230 + 0
230 Btuh
Sensible Envelope Load:
7367 Btuh
-+ -- - - - -_.. -
Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) DGM Ot 0.207 I
-----
1523 Btuh
_ _ _
Sensible Zone Load
8890 Btuh j
.- _.�
'18
19
20
22
23
I Walis
Type'
Panes SHGC_ U InSh
IS Omt
Overhang
Len Hgt
WindowArea(sgft)
_Gross Shaded Unshadetl IC
-2 NFRC 0.28, 0.31
No
No
N
2.Oft
5.Oft
45.0
0.0
45.0
2 NFRC 0.28, 0.31
No
No
N
2.Oft
3.Oft
20.0
0.0
20.0
2 NFRC 0.28. 0.31
No
No
E
2.Oft
5.Oft
42.0
0.0
42.0
2 NFRC 0.26, 0.31
No
No
E
2.Oft
3.Oft
6.8
0.0
6.8
2 NFRC 0.28, 0.31
No
No
E
2.Oft
5.Oft
24.0
0.0
24.0
2 NFRC 0.28, 0.31
No
No
S
25.Of
3.Oft
50.0
50.0
0.0
2 NFRC 0.28, 0.31
No
No
S
25.01'
3.Oft
25.0
25.0
0.0
Window Total
213 (sgft)
Type U-Value R-Value Area(sqft)
11
11
t1
11
11
11
HTM
11
32
32
32
12
12
ICril
Cav/Sheath
9
Concrete BIk,Filled - Ext
0.12
4.110.0
312.0
1.9
10
t Concrete Blk,Filled -Ext
0.12
4.1/0.0
208.8
1.9
11
Concrete BIk,Filled - Ext
0.12
4.1/0.0
135.2
1.9
12
Concrete Blk,Filled -Ext
0.12
4,110.0
238.3
1.9
13
- Int
0.12
0.0/0.0
208.0
0.0
14
- Int
0.12
0.0/0.0
281.7
0.0
Wall Total
1384 (sgft) ..
Ilings
T pe/Color/Surface
U Value
R Value
Area(sgft)
HTN
3
Vented AttictLight/Metal
0.032
30 0/0.0
854.0
1.40
-_
_ Ceiling Total _ __
854 (sgft
___
EnergyGauge® / USRFZB v3.1
213 Stuh
1336 Stuh
217 Btuh
764 Btuh
532 Btuh
266 Btuh
3808 Btuh
582 Btuh
390 Btuh
252 Btuh
445 Btuh
0 Btuh
0 Stuh
1197 Btuh
Page 2
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124', S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL 121412014
Floors Type R-Value Size HTM Load
3 Raised Wood - Adl 19.0 854 (sqft) 0.7 600 Btuh
Imo.. Floor Total 854.0(sgftL __- - 600Btuh
- -
Zone Envelope Subtotal: 7272 Btuh
intration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
_ Natural 0.38 11102 0.13 61.6 1015 Btuh
•emal Occupants Btuh/occupant Appliance Load
6 X 230 + 5500 6880 _ Btuh
gam. _- -- -- _- _ - -
Sensible Envelope Load: 15167 Btuh
[Duct load Average sealed, Supply(R6.0-AtOc), Return(R6.O-Attic) - _ I of 0.207) 1 3135 Btuh
-- -
Sensible Zone Load 18303 Btuh
C,gmponent Ldads for Room #4 Prep Room 2nd Floorzonerl �� „ ai , • � .,I . _ ; , G '-,
I.
�-
Type Overhang WindowArea(sgft) HTM Load
WInd011V Panes SHGC U InSh IS Ornt Len I Gross, Shaded Unshade Shaded Unshaded-
-_. . 1..--'--...-------'--'--
14 � 2 NFRC 0.28, 0.31 No No N 2.Ott 5.Oft 13.5 0.0 13.5 11 11 � 144 Btu
15 { 2 NFRC 0.28, 0.31 No No N 2.Oft 3.0ft 6.0 0.0 6.0 11 11 64 Btuh
29 2 NFRC 0.28, 0.31 No No W 2.0ft 5.Oft 11.3 0.0 11.3 11 32 358 Btuh
30 2 NFRC 0.28, 0.31 No No W 2.Oft 3.Oft 5.0 0.0 5.6 11 32 159 Btuh
Window Total _ _ I-l_36�gft)725 -_.__._._..--HTM Load Btuh
Vllalis Type U-Value R-Value Area(sgft)
Cav/Sheath
15 Concrete Blk,Filled - Ext 0.12 4.1/0.0 84.5 1.9 158 Btuh
16 - Int 0.12 0.010.0 169.0 0.0 0 Btuh
17 Concrete Blk,Filled -Ext 0.12 4.1/0.0 182.0 1.9 340 Btuh
18 Concrete BlUilled - Ext 0.12 4.110.0 74.8 1.9 139 Btuh
19 -Int 0.12 0.010.0 162.0 0.0 0 Btuh
I,C
Wall Total _- _ -,692 (s_gft) _ . 637 Btuh,
-.-. -
etl_mgs_Type/Color/Surtace _ U Value R_Value Area(sgft) _ _ HTM - --Load
T4 ' Vented Attic/Light/Metal 0.032 30.0/0.0 237.0 1.40 332 Btuh
(sgft _ -
Ceiling_Tota237 332 Btuh
l- _-- .__ _ �_-
Floors Type R-Value Size HTM Load
4 Raised Wood - Adl 19.0 237 (sqft) 0.7 166 Btuh
Floor Total 237.0 (sgft) -__ _-_-. 166 Btuh
Zone Envelope Subtotal: 1860 Btuh
EnergyGauge@ I USRFZB v3.1 Page 3
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124, S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
l InfiltrationT Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
nt Natural 0.38 3081 0.05 23.5 387 Btuh
l 9T rnal Occupants Btuhloccupant Appliance Load
ain 1 X 230 + 0 230 Btuh
Sensible Envelope Load: 2477 Btuh
uh
DUCt IOad Average sealed, Supply(R6.0-At1ic), Rm( etuR6.0.Attic) _ _ .�DGM of 0.207 )512 Bt
- .,_.-._ __.�
Sensible Zone Load I 2989 Btuh
Type* Overhan1. g I WindowArea(sgft) HTM Load
WindowFPanesSHGC U InSh IS Ornt Len Hot _Gross Shaded Unshade Shaded Unshaded _
25�NFRC 0.28, 0.31 No No W 6.Oft 5 0ft 15.0 OA 15 0 11 32- 477 Btu'
2 NFRC 0.28, 0.31 No No W 6.0ft 3.Oft 6.0 5.9 0.1 11 32 65 Btuh
'26 i 2 NFRC 0.28, 0.31 No No W 2.0ft 5.Oft 45.0 0.0 45.0 11 32 1432 Btuh
�27 2 NFRC 0.28, 0.31 No No W 2.Oft 3.Oft 18.0 0.0 18.0 11 32 573 Btuh
'28 2 NFRC 0.28, 0.31 No No W 2.Oft 10.Of 18.0 0.0 18.0 11 32 573 Btuh
Window Total _ 102 sgftL i 3120 Btuh
�FNalls Type 9-Value R-Value Area(sgft) HTM Load
Cav/Sheath
20 Concrete Blk,Filled -Ext 0.12 4.1/0.0 101.0 1.9 188 Btuh
21 Concrete Blk,Filled - Ext 0.12 4.110.0 78.0 1.9 146 Btuh
I 26 ,.Concrete BlUilled - Ext 0.12 4.1/0.0 57.0 1.9 106 Btuh
Wall Total 236 (sgL__ 440 Btuh
Ceilings Type/ColorlSurface U Value R Value Area(sgf� HTM Load
- ---
5 Vented Attic/Light/Metal0 032 30 0/0.0 212.0 1.40 297 Btuh
Ceilinq Total 212 (sgft) 297 Btuh
F�oors ! Type R-Value Size HTM Load
5 Raised Wood -Adj 19.0 212 (sgft) 0.7 149 Btuh
Floor Total 212.0 s_ ft) _ 149 Btuh
Zone Envelope Subtotal 4006 Btuh
Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
Natural 0_38 2756 0.04 - . 16.2 -. 268 Btuh
--
Internal Occupants Btuh/occupant Appliance Load
gain 0 X 230 + _ 0- 0 Btuh
Sensible Envelope Load. I 4274 Btuh
- _ -- --
Duct load Average sealed, Supply(R6.0-Attic) Return(R6 0-Attic) _ (DGM of 0.207- 884 Btuh
A --
! Sensible Zone Load 6157 Stuh
i
EnergyGaugeO / USRFZB v3.1
Page 4
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Chmate:FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
Component
12/4/2014
Walls 1 Type U-Value R-Value Area(sqft) HTM Load
Cav/Sheath
27 -Int 0.12 4.1/0.0 78.0 0.0 0 Btuh
28 - Int 0.12 4.1/0.0 - 78.0 0.0 0 Btuh
29 - Int 0.12 4.110.0 78.0 0.0 0 Btuh
Wall Total 234 (sgft) 0 Btuh
Ceiling s Type/Color/Surface U-Value R-Value A_rea(sgft) HT_M Load
6 Vented A IWI ight/Metal 0.032 30.010.0 25.0 1.40 35 Btuh
Ceiling Total 25 (sgft) 35 Btuh
Floors Type R-Value Size HTM Load
6 Interior 0.0 25 (sgft) 0.0 ! 0 Btuh
Floor Total 25.0 (sgft) 0 Btuh
Zone Envelope Subtotal: 35 Btuh
Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
Natural 0.38 325 0.00 0.0 0 8tuh
Internal Occupants Btuh/occupant Appliance Load
ain 0 X 230 + 0 I 0 Btuh
Sensible Envelope Load: 35 Btuh
Duct load_ Average sealed. Supply(R6A-Attic), R_etum(R6.0-_Attic)_ _ (DGM of 0.20> ) _ _ 7 Btuh
Sensible Zone Load 42 Btuh
Walls
Type
U-Value
R-Value
Area(sgft)
HTM
Cav/Sheath
22
-Int
0.12
0.010.0
78.0
0.0
23
- Int
0.12
4.110.0
78.0
0.0
24
I - Int
0.12
0.010.0
78.0
0.0
25
I -Int
0.12
0.0/0.0
78.0
0.0
Wall Total
312 (sgft)
Ceilings
TypelColodSurface
U_Value
R-Value
Area sgft) __.
HTM
7
Vented Attic/Light/Metal
0.032
30.010.0
40.0
1.40
Ceiling Total
40 (sgft)-._
Floors
Type
R-Value
Size
HTM
7
I Raised Wood -Adj
19.0
40 (sgft)
0.7
Floor Total
4 0. 0 (s_ftq)
_
_
- -�
-Zone Envelope Subtotal:
tad
0 Btuh
0 Btuh
0 Btuh
0 Btuh
0 Btuh
56 Btuh
Load
28 Btuh
28 Btuh
84 Btuh
EnergyGauge® / USRFZB v3.1 Page 5
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12I4/2014
Infiltration Type
Wholehouse ACH
0.38
Occupants
0
Duct load I Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic)
Volume(cuft) Wall Ratio
520 U0
Btuhloccupant
X 230 +
CFM=
0.0
Appliance
0
Sensible Envelope Load:
--- -------- ---
(DGM of 0.201
Sensible Zone Load
-.
Window
- —Type;--
Type'
Panes SHGC U InSh
IS G_mt
Overhang
Len H t
- -
WindowArea(sgft) HTM
Gross _Shaded UnshadeQ Shaded_ Unshaded
21 -'
_
2 NFRC 0.28, 0.31 No
No E 19.0f 3.Oft 110.0 110.0 0.0 11
32
Window Total
110(sgft)
i Walls
Type
U-Value R-Value Area(sqft)
HTM
CavlSheath
30
' Concrete BIk,Filled - Exl
0.12 4.V0.0 51.4
1.9
Wall Total
51 (sgft)
Ceilings
Type/Color/Surface
U-Value R-Value Area sgft)
HTM
8
Vented Att0l-ight/Metal
0.032 30.0r0.0 300.0
1.40
Ceiling_ Total
_ 300 (sgft)
Floors
Type
R-Value Size
HTM
8
Raised Wood -Adj
19.0 300 (sgft)
0.7
—
Floor Total --
300.0 s ft
_.
Zone Envelope
Subtotal:
Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM=
Natural 0.38 3900 0.01 3.5
Internal Occupants Btuh/occupant Appliance
gai.__ 4 _X 230 ._.__+ 0
Sensible Envelope Load:
Duct loadl Average sealed, Supply(R6 0-Attic) Return R6 0-Attic) (DGM of 0 207
Sensible Zone Load
Load
0 Btuh
Load
0 Btuh
84 Btuh I
_ 17 _Btuh
102 Btuh
-l�)lIfi Y i
j
Load
1171 B- tuh
1171 Btuh
Load
96 Btuh
96 Btuh
Load _
420 Btuh
420 Btuh
Load
211 Btuh
1898 Btuh
Load
58 Btuh
Load
920 Btuh
2876 Btuh
_595 Btuh
3471 Btuh
EnergyGaugeO / USRFZB v3.1 Page 6
Manual
J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_ST_LUCIE_CO_INTL
812411 S. Ocean Drive Newman Residence Room by Room - Danes AC
Diamond Sands, FL
1214I2014
Coinp�
onent Loads for Room #9 S $d of Living 2nd Floor Zn 2`N I + 4! ,=a� s} „ _, v
Type'
Overhang Window Area(sqft) HTM
Load I
Window Panes SHGC U_IRSh Len Hgt Gross Shaded Unshadej Shaded Unshaded
_is_Omt
31 2 NFRC 0.28, 0.31 No No
E 19.6f 10ft 100.0 100.0 0 0 11 32
1064 Stuh
Window Total
100 (sgft)_._ I.- __.
1064 Btuh ;
.
Load
_
Walls Type U-Value R-Value Area(sgft) HTM
Cav/Sheath
31 Concrete Blk,Filled - Ext
0.12 4.1/0.0 61.4 1.9
115 Btuh
32 - Int
0.12 0.0/0.0 78.0 0.0
0 Btuh
33 - Int
0.12 0.010.0 130.0 0.0
0 Btuh
34 - Int
0.12 0.0/0.0 52.0 0.0
0 Btuh
35 j -Int
0.12 0.0/0.0 260.0 0.0
0 Btuh !
Wall Total
581 (sgft)
_115 Btuh�
Cel-- ---- - --
Ceilings 'Type/Color/Surface
--- .. - ..__._....
U-Value R-Value Area(sqft) HTM_ .
Load
548 Btuh
! 19 Vented Attic/Light(Metal 0.032 30.0/0.0 391.0 1.40
Ceiling Total
391 lsgft)
548 Btuh
-
Floors Type
R-Value Size HTM
Load
9 Raised Wood -Adl
19.0 391 (sgft) 0.7
275 Stun
Floor Total
391.0 (sgft) „,
___
275 Btuh
Zone Envelope Subtotal:
2001 Btuh
Infiltration Type Wholehouse ACH Volume(cuft), Wall Ratio CFM=
I
Load
Natural_
0.38 5083 0.01 4.2
70_ Btuh
Internal
Occupants Btuh/occupant Appliance
Load
am
0 X 230 + 0
0 Btuh !
_
Sensible Envelope Load:
2071 Btuh
Duct load
Average sealed, Supply(R6.0-Attic),
Return(116A-ANic) _ _ _ (_ DGM of 0.479L
973 Btuh
I- -
Sensible Zone Load
3044 Btuh
51 1 Concrete BIk,Filled - Ext
!
Wall Total
Doors
Type -._..
5
Wood - Exterior
Door Total
fI Ceilings
Type/Color/Surface
10
Vented Aftic/Light/Metal
Ceiling Total
r Floors
Type
10
Interior
Floor Total
u-Vaiue H-vaiue
Hrea(sgtt)
Cav/Sheath
0.12 4.110.0
297.0
297 (sgft)
Area (sgft)
28.0
28 (sgft) -
_
U-Value R-Value
Area(sqft)
0.032 30.0/0.0
360.0
360 (sgft)
iTM Load
1.9 654 Btuh
554 Btuh
iTM -Load 1 13.8 I 386 Btuh
1.40
R-Value Size HTM
0.0 360 (sgft) 0.0
504 Btuh
504 Btuh
Load
0 Btuh
0 Btuh
7
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
1214/2014
Zone Envelope Subtotal: 1445 Btuh
Infilltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
Natural 0.38 4680 0.04 20.4 337 Btuh
-_.. .4 -. _..._ . _.... - -- - - - . d
Internal Occupants Btuh/occupant Appliance Load
gain 0 X 230 + -_ 0 - 0 Btuh
8 - -
Sensible Envelope Load: 1782 Btuh
Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.470) 837 Btuh
Sensible Zone Load 2619 Btuh
Type*
ver anqT Windowkea(sgft) HTM
Load
Window
Panes SHGC U InSh
IS Ornt Len
Hgt Gross Shaded_Unshade
Shaded
_ Unshaded
32
2 NFRC 0.28, 0.31 No
No
E 9.Oft
5.Oft I 30.0
14.8 15.2
11
32
641 Btuh
33
12 NFRC 0.28. 0.31 No
No
E 9.0ft
3.Oft 6.0
6.0 0.0
11
32
64 Btuh
34
2 NFRC 0.28, 0.31 No
No
E 9.Oft
5.Oft 20.0
9.9 10.1
11
32
427 Btuh
35
2 NFRC 0.28, Ull No
No
S 2.011
5.0ft 12.5
12.5 0.0
11
12
133 Btuh
36
2 NFRC 0.28. 0.31 No
No
S, 2.Oft
3.Oft 5.0
5.0 0.0 1
11
12
53 Btuh
Window Total
74 (sqft)
1318 Btuh
Load
Walls
____
- Type U-Value R-Value Area(sqft) HTM
Cav/Sheath
36
Concrete BIk,Filled - Ext
0.12
4.1/0.0
220.3
1.9
411 Btuh
37
Concrete BlUilled - Ext
0.12
4.1/0.0
269.0
1.9
502 Btuh !
38
Concrete BlUilled - Ext
0.12
4.1/0.0
229.5
1.9
428 Btuh
139
Concrete BlUilled - Ext
0.12
4.1/0.0
117.0
1.9
218 Btuh
40
-Int
0.12
0.0/0.0
91.0
0.0
0 81uh
43
- Int
0.12
0.0/0.0
104.0
0.0
0 Btuh
Wall Total
Type
1031 (sqft)
Area (sqft)
HTM
1559 Btuh
Doors
Load
6
. Wood - Exterior
26.7
13.8
368 Btuh
i Door Total
368 Btuh_
Ceilings
I Type/Colod3urface
_ U-Value
_
R-Value
_
Area(Sgft)
HTM
Load
11
Vented Attic/Light/Metal
0.032
30.0/0.0
582.0
1.40
816 Btuh
Gelling Total
582 (sgft)
816 Btuh
Floors
Type
..._-
R-Value
Size
HTM
Load
11
Raised Wood -Adj
19,0
582 (sqft)
0.7
409 Btuh
Floor Total
582.0 (sqft)
409 Btuh
Zone Envelope Subtotal:
4469 Btuh
EnergyGaugeO / USRFZB v3.1 Page 8
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_ST_LLICIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Dares AC
Diamond Sands, FL
12/412014
infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
Natural 0.38 7566 0.12 57.5 949 Btuh
Internal Occupants Btuh/occupant Appliance' load
gain460 Btuh
-2230 - -- -_... +, . �_.._..--.-._-77
Sensible Envelope Load: 5878 Btuh
Du CtAverageload sealed, Supply(R6 0 Attic), Retum(R6 0.Attic) _ _ (DGM of 0 470) 2761 Btuh _
Sensible Zone Load 8639 Btuh
i
�- Type' Overhang • WindowArea(sgft) HTM Load
WindoW Panes SHGC U InSh IS Ornt Len Hgt_. Gross Shaded Un_shade__ Shaded Unshaded _ ..__ `
-- ---- .. _._- --- -- ----- ----- - ,
39 2 NFRC 0.28, 0.31 No No S 2.Oft 5.0ft ' 20.0 20.0 0.0 11 12 213 Btuh
40 2 NFRC 0.28, 0.31 No No S 2.Oft 'l oft , 8.0 8.0 0.0 11 12 85 Btuh
41 2 NFRC 0.28, 0.31 No No S 2.Oft ;.Oft 25.0 25.0 0.0 1 11 12 266 Btuh
42 2 NFRC 0.28, 0.31 No No S 2.Oft 3.Oft 10.0 10.0 0.0 11 12 106 Btuh
Window Total 63 (sgft)- 671 Btuh
Wails Type U-Value R-Value Area(sgft) HTM Load
Cav/Sheath
41 Concrete Blk,Hollow -Ext 0.15 4.110.0 158.0 2.2 354 Btuh
42 Concrete Blk,Filled - Ext 0.12 4.1l0.0 26.0 1.9 49 Btuh
44 -Int 0.12 0.010.0 169.0 0.0 0 Btuh
Wall Total 353 (sgft) _ _ ! 402 Btuh-11
Ceilings Type/Color/Surface LI-Value R Value Area(sgt) HTM Load
12 Vented Attic/Light/Metal 0.032 30.010.0 256.0 1.40 359 Btuh
Ceiling Total 256 s ft 359 Btuh
Floors Type R Value Size HTM Load
12 Raised Wood - AdJ 19.0 256 (sqft) 0.7 180 Btuh
Floor Total 256.0 {sgft)_ 180 Btuh
Zone Envelope Subtotal: 1611 Btuh
Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
Natural 0.38 3328 0.03 12.7 209 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 0 X 230 + 0 0 Btuh.
Sensible Envelope Load: 1820 Btuh
DGM of 0.470 855 Btuh
ct load Average sealedSupply(R6.0-Attic), Retum(R6 0 Attic) (___. _ .�_
Du ,
Sensible Zone Load 2676 Btuh
EnergyGauge®! USRFZB v3.1 Page 9
• Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL-STJUClE-CO-1NTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
Component Loads for Room #13 d
-HTM
-- - ----Type` 5ve-rh-an6']-Winci5.Oft
Load
12.5 0.0 11oWArea(-sqft)-T-
Window Panes SH Lon H91 Gross Shaded unshaded Shaded Unshaded
III 12
I 3-3-EtFtUl
37 2 NFRC 0.28. 0.3 1 No No 2.Oft 12.5
38 2 NFRC 0.28.0.31 No No Sj 2.Oft 3.Oft 5.0 5.0 0.0 11 12
53 Btuh
43 2 NFRC 0.28.0.31 No No W ' 2 Oft 5.Oft 25.0 0.0 25.0 11 32
796 Btuh
44 2 NFRC 0.28, 0.31 No No W 3.Oft to,, 0,0 10,0 11 12
3111 Btuh
45 2 NFRC 0.28,0.31 No No W Oft 10.0 0.0 10.0 11 32
318 Btuh
L210.0f
46 2 NFRC 0.28,0.31 No No W 2 t 5.Oft 10.0 0.0 10.0 11 32
00ft
318 Btuh
10ft 5.0
2 NFRC 0.28.0.31 No No W 0.0 5.0 11 32
47 2
159 Btuh
Window Total -- ---- -
2095 Btuh
Load
Walls i Type U-Value R-Value Area(scift) HTM
Cav/Sheath
45 Concrete 81k,Filled - Ext 0.12 4.1/0.0 216.5 1.9
404 Btuh
46 Concrete Blk,Filled - Ext 0.12 4.110.0 137.0 1.9
256 Btuh
47 Concrete BlUilled - Ext 0.12 4.1/0.0 26.0 1.9
49 Btuh
48 - Int 0.12 0.010.0 78.0 0.0
0 Btuh
,49 Concrete Blk,Filled - Ext 0.12 4.110.0 63.0 1.9
118 Btuh
50 - Int 0.12 0.010.0 143.0 0.0
0 Btuh
Wall Total 664 (sq�T
825 Btuh
Ceilin Type/ Value [Wifue Ama �sqft) HTM
Color/Surface
Load
419 Btuh
'13 Vented AtticiLlght/Metal 0.032 30.010.0 299.0 1.40
Ceiling Total .....,,299(sq
419 B.tuh.
Floors -rppa- R-Value Size HTM
Load
13 1 Raised Wood - Adl 19.0 299 (sqft) 0.7
210 Btuh
Floor Total 299.0
210 Btuh
Zone Envelope Subtotal:
3550 Btu
Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFMz
I Load
Natural 0.38 3887 0.07 30.6
-
502 - Btuh i
- - - ---------
Internal Occupants Btuh/occupant Appliance
Load
gain 0 X 230 + 0
0 Btuh
--- - ------
Sensible Envelope Load:
4052 Btuh
ctload Average sealed, Supply(U.O-Attic), Ret�u ( 6.0-Attic) (DGM of 0.470)
1903 Btuh
Sensible Zone Load
5955 Btuh
EnergyGaugeO I USRFZB v3.1 Page 10
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL-ST-LUCIE-CO-INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/412014
Component Loads for .777777T
F
Walls Type U-Value R-Value Area(sqft) HTM
Loa
Cav/Sheath
67 Int 0.12 4.1/0.0 72.0 0.0
Stuh
68 - Int 0.12 4.110.0 72.0 0.0
0 Btuh]
169 - Int 0.12 4.110.0 72.0 0.0
0 Btuh
Wall Total 216 (so-ft.)
0 Btuh-
...... .. .
ellinigs TypetColor/Surface U-Value R-Value Area(sqft) HTM
Load
i 14 Vented A ghUMetal 0.032 30.0/0.0 25.0 1.40
35 Btuh
Ceiling Total 25 (sqft)
35 Btuh
Floors Type R-Value Size HTM
Load
14 Interior 0.0 25 (sqft) 0.0
0 Stuh
Floor Total 25.0 (sqft)
0 Btuh
Zone Envelope Subtotal:
35 Btuh
I Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM=
Load
Natural 0.38 300 0.00 0.0
I
i ___0_Btuh
Internal Occupants - . Btuh/occupant Appliance
Load
0 X 230 + 0
0 Btuh
Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic)
I Type*
idow Panes SHGC U InSh IS Ornt
3 2 NFRC 0.28, 0.31 No No N
7 2 NFRC 0.28,0.31 No No E
Window Total
falls
Type
62
Concrete Blk,Filled - Ext
53
Concrete Blk,Filled - Ext
54
Concrete BlUilled - Ext
55
- Int
56
-Int
Wall Total
15 1 Vented AttictUghlWelal
Ceiling Total
-0-1013j74j - -1-;fip-e--- --
15 Interior
I Floor Total
Overhang
Len Hot
Kelf,
Sensible Envelope Load
(DGM of 0.35,
Sensible Zone Load
rea(sqffl 1 HTM
75.0 0.0 75.0
100 (sqft)
U-Value R-Value
Cav/Sheath
11 32
11111117
0.12
4.110.0
167.0
19
0.12
4.1/0.0
177.0
1.9
0.12
4.110.0
192.0
1.9
0.12
0.010.0
156.0
0.0
0.12
0.010.0
60.0
0.0
U-Vaue
lue
R-Value
Area(s
HTM_
0.032
30.0/0.0
395.0
1.40
395 (sqft)_
R-Value
Size
HTM
0.0
395 (sqft)
0.0
395.0(sqft)__
EnergyGauge@ I USRFZB v3.1
35 Btuh
2 Btuh
47 Btuh
Load -2
23
312 Stun
330 Stuh
358 Stuh
0 Stun
0 Stuff
1000 Btuh I
Load
554 Btuh
554 Btuhl_
Load
0 Btuh
0 Btuh
Page 11
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
81241S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
Infiltration Type
12/412014
Zone Envelope Subtotal: 4206 Btuh
Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
— 0.38 4740 _0`08 — 36.9 _-608 Btuh
Occupants Btuh/occupant Appliance' Load
0 X 230 + 0 _0 Btuh
Sensible Envelope Load: 4814 Btuh
DGM of 0.352 1694 Btuh
_Average sealed, Supply(_R6.0-Attic),-Retum(ft6.0•Attic) . ___„ _�_.. ,. __ �--__..__.—_
Sensible Zone Load 1 6509 Btuh
Type*
Overhang
Window
--- ...
HTM
Window
ndoW StIG U INS
OmN Len_,�H t_..
qeg Ungft)
Gross Shaded lJnshade__Shaded Unshaded
�_ _
-�---
2 NFRC 0.
_ ,,
No
2.Oft 4.6h
25.0 0.0 25.0 11
11
6 2 NFRC 0.28, 0.31 No
No N
2.01t 4.0ft
8.0 0.0 8.0 11
11
Window Total
1
33 i...—_
.__..
Walis yTlpe
._ __
U-Value R-Value Area(sqft)
HTM
57 Concrete Blk,Filled -Ext
Cav/Sheath
0.12 4.1/0.0 87.0
1.9
58
- Int
0.12 0.010.0 120.0
0.0
59
- Int
0.12 0.0/0.0 144.0
0.0
Well Total
351 (s9ft�._.___---
Ceilinas
TVOe/Cdlor/Surface
---.._.._- ---,-
U-Value R-Value_ Area(sgft)_—
_HTM
Floors
16
Vented AtticILight/Metal 0.032
Ceiling Total
Interior
Floor Total_-_
30.0/0.0 120.0 1.40
- — __ 120 (sq�_ —
Value Size HTh
0.0 120 (sgft) 0.0
Type Wholehouse ACH
Natural 0.38
- Occupants
0
Zone Envelope Subtotal:
Volume(cuft) Wall Ratio CFM=
1440 0.01 6.0
Btuh/occupant Applian(
X 230 + 0
Sensible Envelope Load:
(DGM of 0.352
DUCt load I Average sealed, Supply(R6.0Attic), Return(R6.0-Attic) , _-_.- ....
Sensible Zone Load
EnergyGauge® / USRFZB v3.1
.oad
_...266 -._Bt�
85 Btuh
351 Btuh
Load
162 Btuh
0 Btuh
0 Btuh
162 Btuh
168 Btuh
168 Btuh
Load
0 Btuh
0 Btuh
682 Btuh
Load
99 Btuh
Load
0 Btuh
780 Btuh
275 Btuh I
1065 Btuh
Page 12
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124
S. Ocean Drive
Newman Residence Room by Roam - Danes AC
Diamond Sands, FL
12/412014
l Component�Loatls
r--- ,
for Room #17 VIP WIC 31'd Flggr Zone 3+r'r' `; r; � lr, �`, , ` r
Walls Type
HTM Load
U-Value R-Value Area(sgft)
j I
i
Cav/Sheath
89
- Int
0.12 0.0/0.0 120.0
0.0
0 Btuh
Wall Total
120 (sgft)
_ 0 Btuh
Cellln s
T pe/Color/Surface
U-Value R-Value Area(sqft)
HTM
Load
17
Vented AttickightNetal
0.032 30.0/0.0 41.0 1.40
Ceiling Total_
41 (sgft)_
Floors
Type
R-Value Size HTM
17
Interior
0.0 41 (sgft) 0.0
Floor Total
41.0 (sgft) _ _-
r
i infiltration ,Type
I Natm
18 1 Vented
18 I Interior
Zone Envelope Subtotal
Wholehouse ACH Volume(cuft) Wall Ratio CFM=
11 0.38 492 0.00 0.0
Occupants Btuh/occupant Appliance
0 X 230 + 0
........-- — —
Sensible Envelope Load:
3 sealed, Supply(R6.0-Attic), Retum(R6.0-Attic) _ (DGM of 0_352)
Sensible Zone Load
ce U-Value R-Value
Area s ft
HTM
�tal 0.032 30.010.0
231.0
1.40
231_(s_9ft�._
.
_ _ R-Value
Size
HTM
0.0
231 (sqft)
0.0
231.0 sgft_ ..
Zone Envelope Subtotal:
lfiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM=
J Natural 0.38 2772 0.00 _ 0.0
in—tirrial Occupants Btuhloccupant Appliance
gain J 0 X 230 + 0
Sensible Envelope Load:
EnergyGauge® / USRFZB v3.1
57 Btuh
57 Btuh
ad
0 Btuh
0 Btuh
57 Btuh
Load
0 Btuh
Load
0 Btuh_
57 Btuh
20 Btuh
78 Btuh
r
, Y
Load
324 Btuh
324 Btuh
Load
0 Btuh
0-Btuh I
324 Btuh
Load
0 Btuh
Load
0 Btuh
324 Btuh 1
Page 13
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124!S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
DgCt load i Average sealed, Supp1y(R6.0-Attic), Retum(R6.0AttIC)
(DGM of 0352)� 114 Btuh
Sensible Zone Load 438 Btuh
Type* Over WindowArea(sgft) HTM Load
Window Panes_ SHGC U InSh
IS Omt-
Len_ Hgt Gross,._
Shad
.
4
;
2 NFRC 0.28, 0.31 No
No N
2AR
4.Oft1 25.0
0.0
10
2 NFRC 0.26, 0.31 No
No W
2.011
4.Oft 1 25.0
0.0
Window Total
50 (sgft)
Wall
ype
Ts
U-Value
R-Value
An
Cav/Sheath
60
Concrete BlUilled - Ext
0.12
4.1/0.0
61
-Int
0.12
0.0/0.0
'62
Concrete BlUilled - Ext
0.12
4.1/0.0
''.63
Concrete BlUilled - Ext
0.12
4.1/0.0
164
- Int
0.12
0.0/0.0
�.65
- Int
0.12
0.0/0.0
166
-Int
0.12
4.110.0
Vented Attie/Light/Metal
Ceiling Total
19 Interior
Floor Total
Infiltration Type
25.0 11 11-266 Btuh
25.0 1 11 32 796 Btuh
1062 Btuh
ift) HTM Load
60.0
1.9
112 Btuh
60.0
0.0
0 Btuh
143.0
1.9
267 Btuh
227.0
1.9
423 Btuh
108.0
0.0
0 Btuh
96.0
0.0
0 Btuh
72.0
0.0
0 Btuh
766 (sgft)
802 Btuh
U-Value R-Value Area(sgft) HTM _ Load
0.032 30.0/0.0 237.0 1.40 332 Btuh
937 /soft) 332 Btuh
R-Value Size HTM
0.0 237 (sqft) 0.0
237.0 sgft)- ...--..-..
Zone Envelope Subtotal:
Wholehouse ACH
0.38
Occupants
0
Average sealed,. Supply(R(3.0-Attic), Return(R6.0-Attic)
Volume(cuft) Wall Ratio CFM=
2844 0.06 29.6
Btuh%occupant Applian
X 230 + 0_
Sensible Envelope Load:
tDGM of 0 352)
Sensible Zone Load
0 Btuh
0 Btuh
2196 Btuh
Load
_ 488 Btuh
Load
0 Btuh
2684 Btuh
945 Btuh
3629 Btuh
EnergyGaugeO / USRFZB v3.1 Page 14
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
82
83
84
85
86
87
88
Type` Overhang I WindowArea(sgft) T HTM
Panes SHGC U InSh
IS Omt Len
Hgt
Gro:
2 aFR6 0.28, 0.31 No
No E' g.dit
4.06
84.
Window Total
84
Type
U-Value
R-Value
Cav/Sheath
- Int
0.12
0.010.0
- Int
0.12
0.010.0
- Int
0.12
0.0/0.0
Concrete BlUilled - Ext
0.12
4.110.0
- Int
0.12
0.0/0.0
- Int
0.12
0.010.0
- Int
0.12
0.010.0
Wall Total
20 1 Vented Akic/LIghttMetal
- :::_
Floors 'Type
20 Interior
Floor Total
Infiltration Type
Natural
Duct load
96.0
0.0
60.0
0.0
120.0
0.0
72.0
1.9
84.0
0.0
96.0
0.0
48.0
0.0
676(sgft)
U-V_alue i2-Value Area(sgft)
_ HTM
0.032 30.010.0 225.0
1.40
225
R-Value Size
HTM
0.0 225 (sqk)
0.0
225.0
Zone Envelope
Subtotal:
Wholehouse ACH Volume(cuft) Wall Ratio
CFM=
0.38 2700 0.01
5.0
Occupants Btuh/occupant
Appliance
0 X 230 +
0
Sensible Envelope Load:
Retum(R6.0-Attic)
(DGM
Sensible Zone Load
Type
verhang WindowArea(sgft) HTM
Window
Window I
-Panes SHGC U InSh
2 NFRC 0.28.0.31 No
IS Oen Hgt Gross. Shaded Unshaded Shaded
No 4.Ok 72.0 31.2 40 8 i 11
4E9.Oft
Unshadi
32
11
Window Total
Type
72 (sgft)_-, - __. I
U-Value R-Value Area(sqft)
HTM
Walls
Cav/Sheath
77
Concrete BIk,Filled - Ext
0.12 4.1/0.0 108.0
1.9
78
Concrete BlUilled - Ext
0.12 4.1/0.0 156.0
1.9
79
Concrete BlUilled - Ext
0.12 4.1/0.0 84.0
1.9
80
- Int
0.12 0.010.0 144.0
0.0
81
-Int
0.12 0.010.0 96.0
0.0
Wall Total___
-
588(sgft)
- EnergyGauge® /lJ8RFZI3 v3.1 - -
_
""
Load
1901 Btuh
Load
0 Btuh
0 Btuh
0 Btuh
134 Btuh
0 Btuh
0 Btuh
0 Stuh
134 Btuh
315 Btuh
315 Btuh
0 Btuh
0 Btuh
2351 Btuh
Load
82 Btuh
Load
0 Btuh_
2433 Btuh
856 Btuh
3289 Btuh
Load
201 Btuh
291 Btuh
157 Btuh
0 Btuh
0 Btuh
649 Btuh
-image 15
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
Ceiling
Mf
Load
315 Btuh
21 i
Vented Attic/Light/Metal 0.032 30.010.0 225.0 1.40
Ceiling Total 225 (sgft)
315 Btuh
Floors
Type R-Value Size HTM
Load
j ,21
Interior 0.0 225 (sqft) 0.0
0 Btuh
Floor Total 225.0 (sgft)
Zone Envelope Subtotal:
____...._0,.Btuh__.
2594 Btuh
infiltration
rLoad
Type Wholehouse ACH Volume(cuft) Wall Ratio CFM=
Natural 0.38 2700 0.05 24.0
395 Btuh
Internal
_. _
Occupants Btuh/occupant Appliance
Load
I gain -_
;, 0 X 230 + 0
0 Btuh
Sensible Envelope Load:
2989 Btuh
Duct load
Average sealed,.Supply(R(3.0-Attic) Retunn(R6.0-Attic) (DGM of 0.352) _�
Sensible Zone Load
1052 Stuh
I 4041 Btuh
Type' Overhang V�ndowArea(sgft) HTM Load
Window Panes SHGC U InSh IS Or_nt Len Hgt Gross Shaded Unshade_ Shaded Unshaded
12-.._... ... _-..-
.. _ __-.. _. _.._. 2 NFRC 0.26, 0.31 No No W 6.Oft 4.OR 12.5 2.4 10.1 11 32 346 Btuh
13 2 NFRC 0.28, 0.31 No No W 6.Oft 4.Oft 32.0 3.9 28.1 I 11 32 935 Btuh
Window Total _, 45 (sgft) _ .. 1281 Btuh
__..---
..Ty-- ....._
Walls pe U-Value R-Value Area(sqft) HTM Load
Cav/Sheath
73 Concrete BIk,Filled - Ext 0.12 4.1/0.0 162.2 1.9 303 Btuh
74 Concrete BlUilled - Ext 0.12 4.1/0.0 204.0 1.9 381 Btuh
75 -Int 0.12 0.010.0 96.0 0.0 0 Btuh
Do
76 Int 0.12 0.0/0.0 MO 0.0 0 Btuh I
Wall Total _ _ _-.. ._ __ 522 (sgft)683 Btuh
oors Type Area (sqft) HTM Load
7 : Wood - Exterior 21.3 13.8 294 Btuh
Door Total 21 sgft) 294 Btuh
Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load
23 Vented Attic/Light/Metal 0.032 30.0/0.0 347.0 1.40 486 Btuh
Ceiling Total _ 347_(sSc ft�_ _ _-_ _ .L_ 486 Btuh
Floors Type R-Value Size HTM Load
22 Interior 0.0 347 (sgft) 0.0 I 0 Stuh
L- Floor Total 347.0 (sgft) _ _ 0 Btuh
Zone Envelope Subtotal: 2745 Btuh
EnergyGauge® / USRFZB v3.1 Page 16
• Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
jlnfiltration Type
I7
Intemal .
I in —
Duct load Average seale
Wholehouse ACH Volume(cuft) Wall Ratio CFM=
0.38 4164 0.05 25.2
Occupants Btuh/occupant Appliance
4 X 230 + 0
_. _ ........
_ _.. - - -
-- Sensible Envelope Load:
Supply(R6.0-Attic), Raturn(R6.0-Attic) — (DGM of 0_352Z
Sensible Zone Load
Load
416 Btuh
4080 Btuh
1436 Btuh {'
5517 Btuh
Type' Overhang WindowArea(sgft) HT
Load
Window Panes SHGC U InSh IS Ornt Len Hgt Gross Shaded Unshade Shaded U_ Unshaded I rnt — --
I� 9 2 NFRC d 28 0.31 No No W i 6 Ofl 4.Oft 12.5 2 4 70 i 11 32 346 B[uh
Window Total _ 13 (sgft) 346 Btuh
---_. _
Walls Type U-Value R-Value Area(sqft) HTM i Load
CaWsheath
i 70 Concrete BIk,Filled - Ext 0.12 4.1/0.0 132.0 1.9 246 Btuh
I 71 Concrete SIk,Fllled - Ext 0.12 4.1/0.0 59.5 1.9 111 Btuh
72 I - Int 0.12 0.010.0 132.0 0.0 0 Btuh
Wall Total 324 s ft) 357 Btuh
C_eilin_gs Type/Color/Surfa_ceU-Value R-Value A_rea(aft)_ HTM_ Load
I 22 1 Vented AuicUghtlMetal 0.032 30.010.0 60.0 1.40 84 Btuh
Ceiling Total _— _ . 60 (sg� _.. 84 Btuh
Floors Type R-Value Size HTM Load
�23 Interior 0.0 60(sgft) 0.0 0 Btuh
Floor Total 60:0 (sgft) 0 Btuh
Zone Envelope Subtotal: i 787 Btuh
Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load I
Natural _ _ 0.38 _ 720 0.03 13.2 _ 217 Stuh
Internal Occupants Btuh/occupant Appliance Load
gain _ 0 X 230 + 0 0 Btuh
Sensible Envelope Load: 1005 Btuh
Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.352) 354 Btuh_
L.
Sensible Zone Load 1368 Btuh
EnergyGauge® / USRFZB v3.1 Page 17
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
1214/2014
EnergyGauge®! USRFZB v3.1 Page 18
A
' Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
1
rx + .Y-� ii��'ql
�YST�MGROUPS (BLOCK LOABS)�: �'' b 1 tz' „a n ` y a ( 2 ,
f u / ,
J
Sensible Envelope Load
33230 Btuh
Window Excursion
0 Btuh
Cooling Loads
Sensible Duct Load (duct gain multiplier of 0.207)
6869 Btuh
Sensible ventilation
0 Btuh
For Systern(s):
Zone Sensible gain
40099 Btuh
1
Latent infiltration/ventilation gain
9711 Btuh
Serving Zones:
Latent duct gain
3098 Btuh
1, 2, 3, 4, 5, 6, 7, 8
Latent occupant gain
2600 Btuh
Latent other gain
0 Btuh
Total block load
55508 Btuh
Sensible Envelope Load
15604 Btuh
Window Excursion
0 Btuh
Cooling Loads
Sensible Duct Load (duct gain multiplier of 0.470)
7328 Btuh
Sensible ventilation
0 Btuh
For System(s):
Zone Sensible gain
22932 Btuh
2
Latent infiltration/ventilation gain
6132 Btuh
Serving Zones:
Latent duct gain
3495 Btuh
9,10, 11, 12, 13
Latent occupant gain
400 Btuh
Latent other gain
0 Btuh
Total block load
32960 Btuh
EnergyGauge® / USRFZB v3.1 Page 19
Manual J Summer Calculations
Residential Load - Component Details (continued)
I Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124 S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/4/2014
Sensible Envelope Load
19202 Btuh
Window Excursion
0 Btuh
Cooling Loads
i
Sensible Duct Load (duct gain multiplier of 0.352)
6758 Btuh
Sensible ventilation
0 Btuh
j For System(s):
Zone Sensible gain
26960 Btuh
3
Latent infiltration/ventilation gain
6840 Btuh
Serving Zones:
Latent duct gain
3241 Btuh
141 16,16,17,18,19, 20, 21, 2
Latent occupant gain
800 Btuh
Latent other gain
0 Btuh
jTotal
block load
36840 Btuh
Sensible Envelope Load All Zones
68035 Btuh
Sensible Duct Load
20955 Btuh
Total Sensible Zone Loads
88991 Btuh
Sensible ventilation
0 Btuh
i
Blower
147 Btuh
Whole House
Total sensible gain
89138 Btuh
Totals for Cooling
Latent infiltration gain (for 72 gr. humidity difference)
22683 Btuh
Latent ventilation gain
0 Btuh
Latent duct gain
9834 Btuh
Latent occupant gain (10.0 people @ 200 Btuh per person)
3800 Stuh
Latent other gain
0 Btuh
I
Latent total gain
36317 Btuh
TOTAL GAIN
1 126455 Btuh
EQ�JIPMENT
_ x , . a a .h.> rt,�
1.
Central Unit
#
48000 Btuh
2.
Central Unit
#
48000 Btuh
3.
Central Unit
#
48000 Btuh
e 20
J
A
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_ST_LUCIE_CO_INTL
8124S. Ocean Drive Newman Residence Room by Room - Danas AC
Diamond Sands, FL
12/412014
*Key: Window types (Panes - Number and type of panes of glass)
(SHGC - Shading coefficient of glass as SHGC numerical value)
(U - Window U-Factor)
(InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R))
- For Blinds: Assume medium color, half closed
For Draperies: Assume medium weave; half dosed
For Roller shades: Assume translucent, half closed
(IS - Insect screen: none(N), Full(F) or Half(''/))
(Ornt - compass orientation)
EnergyGauge®/ USRFZB v3.1
Apnd6Y t
Amu
Page