Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 110,QA-08 FLOI46A ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: OWENS RESIDENCE Builder Name:•, , Street: 2403 ST. LUCIE BLVD. Permit Office: - SCANNE® City, state, Zip: FT. PIERCE, FL, Permit Number. BY 07+ner. Jurisdiction: COUnty Design Location: FL, Fort Pierce St Lucie 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=8.0 1404.00 ft2 b. WA R= ft 3. Number of units, if multiple family 1 r- N/A R= ft' 4. Number of Bedrooms 1 d. WA R= ft' 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. Conditioned floor area (ft� 140D a. Under Attic (Vented) - R=30.0 1400.00 ft' b. N/A R= ft' 7. Windows Description Area c. WA R= ft' a. U-Factor. Sgl, default 90.00 ft' SHGC: Clear, default 11. Ducts b. U-Factor. WA ft' a. Sup: Attic Rat Attic AH: Interior Sup. R= 6,112 ft' SHGC: 12. Coaling systems c. U-Factor: N/A ft' a. Central Unit Cap: 29.4 kBtu/hr SHGC: SEER: 14 d. U-Factor. N/A ft'' 13. Heating systems SHGC: a. Electric Heat Pump Cap: 29.4 kBtu/hr e. U-Factor. N/A ft' HSPF: 8.4 SHGC: 14. Hot water systems B. Floor Types Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Glade Edge Insulation R=0.0 1400.00 ft' EF: 0.9 b. WA R= ft' b. Conservation features c. N/A R= ft' None 15. Credits.. Pstat Total As -Built Modified Loads: 22.35 Glass/Floor Area: 0.064 PASS Total Baseline Loads: 29.10 1 hereby certify that the plans and specifications covered by Review of the plans and OFq%E STq?� this calculation are in compliance with the Florida Energy specifications covered by this V Code. calculation indicates compliance q�.i„%' �O with the Florida Energy Code. !ti nm.:. "'.; `,r: _•. °u PREPARE Y: 1 y �xr��A� Before construction is completed DATE:— f this building will be inspected for compliance with Section 553.908 0 ° c I hereby certify that this building, as lesigned, is in compliandl Florida Statutes. with the Florida Energy Code. IV/1` COD W{i CRJ OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: .. � FILE J� 7/6/2010 11:51 AM EnergyGauge® USA - FlaRes2008 Page 1 of 5 :I „r PROJECT Title: OWENS RESIDENCE Bedrooms: 1 Adress Type: Street Address .. Building Type: FLAsBuilt Bathrooms: 0 Lot# Owner. Conditioned Area: 1400 SubDivision: 1 of Units: 1 Total Stories: 1 PlatBook: Builder Name: Worst Case: No Street: 2403 ST. LUCIE BLVD. Permit Office: Rotate Angle: 0 County: ST. LUCIE COUNTY Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, Family Type: Single-family Whole House Fan: No FL, New/Existing: New (From Plans) 'Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE CO INTL 2 39 I 90 75 70 722 62 Low FLOORS # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 155.9 ft 0 1400 ft' 0 0 1 ROOF . Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Gable or Shed Composition shingles 1475 ft' 232 ft' Medium 0.9 N 0 18.4 deg ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1400 ft' N N CEILING # Ceiling Type R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) 30 1400 ft' 0.1 Wood WALLS Cavity Sheathing Framing Solar # Omt Adjacent To Wall Type R-Value Area R-Value Fraction Absor. 1 N Exterior Concrete Block - Ext Insul 8 369 ft' 0 0.8 2 E Exterior Concrete Block - Ext Insul 8 333 ft' 0 0 0.8 3 S Exterior Concrete Block - Ext Insul 8 369 ft' 0 0 0.8 4 W Exterior Concrete Block - Ext Insul 8 333 ft' 0 0 0.8 DOORS # Ornt Door Type Storms U-Value Area _ 1 S Insulated 2 W Insulated None None 0.39 21 ft' 0.39 21 ft' WINDOWS Window orientation below is as entered. Actual orientation is modified by rotate an le shown in "Project" section above. # Ornt Frame Panes NFRC U-Factor SHGC Storms Overhang Area Depth Separation Int Shade Screening _ 1 N Metal Single (Clear) 2 E Metal Single (Clear) 3 S Metal Single (Clear) 4 W Metal Single (Clear) No No No No 1.3 0.75 N 1.3 0.75 N 1.3 0.75 N 1.3 0.75 N 15 ft' 2 it 0 in 6 ft 0 in HERS 2006 30 ft' 2 ft 0 in 6 it 0 in HERS 2006 30 ft' 2 it 0 in 6 ft 0 in HERS 2006 15 ft' 2 ft 0 in 6 it 0 in HERS 2006 None None None None INFILTRATION & VENTING / v Method SLA CFM 50 ACH 50 ELA EgLA -- Forced Ventilation — Run Time Supply CFM Exhaust CFM Fraction Fan Watts Default 0.00036 1322 7.08 72.6 136.5 0 cfrm 0 cfm 0 0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ductless 1 Central Unit None SEER: 14 29.4 kBtu/hr cfrm 0.7 FALSE HEATING SYSTEM # System Type Subtype Efficiency Capacity Ductless 1 Electric Heat Pump None HSPF: 8.4 29.4 kBtu/hr FALSE HOT WATER SYSTEM #1 System Type EF Cap Use SetPnt Conservation 1 Electric 0.9 40 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS —Supply— # Location R-Value Area --Return Location Area Leakage Type Air Percent Handler CFM 25 Leakage ON RLF 1 Attic 6 112 ft' Attic 20112 Default Leakage Interior TEMPERATURES Programable[ Thermosta[[tXX:]]Y CFans: Heat InJan [X] Feb [[XX]] (X] Mar Apr[[[eiling Jun j�X j]] Jul [[XX]] [X] Aug [[[XX�]]] Sep Oct [[XX]] NovfDec Nov Dec tjenhn9 [X] Jan lxl [[�X11 Feb [[�XII Mar lxl Apr [X� May Jun [X] Jul LnJ [[�X1) Aug [Xl Lxl Sep Lnl Lxl Oct [X] [Xi Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 FORM 1100A-08 _ Code Compliance Cheklist,�� Residential Whole Building Performance Method Iscopy ADDRESS: 2403 ST. LUCIE BLVD. PERMIT #: FT. PIERCE, FL, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5 dm/s .ft. door area. Exterior & Adjacent Walls N1106.AB.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2.2 Penetrations/openings > 118" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi-storyHouses N1106.AB.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Duds in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.6.1.1 sides. Common ceiling & floors R-11. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the EnergyPerformance Index, the more efficient the home. 2403 ST. LUCIE BLVD., FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=8.0 1404.00 ft' b. N/A R= ft' 3. Number of units, if multiple family 1 c. WA R= ft' 4. Number of Bedrooms 1 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. Conditioned floor area (n 1400 a. Under Attic (Vented) R=30.0 1400.00 ft' b. N/A R= ft' 7. Windows" Description Area c. WA R= ft' a. U-Factor: Sgi, default 90.00 ft' SHGC: Clear, default 11. Duds b. U-Factor: N/A ft' a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 112 ft' SHGC: 12. Cooling systems c. U-Factor. WA ft' a. Central Unit Cap: 29.4 kBtu/hr SHGC: SEER: 14 d. U-Factor. WA ft' 13. Heating systems SHGC: a. Electric Heat Pump Cap: 29.4 kBtu/hr e. U-Factor. N/A ft' HSPF: 8.4 SHGC: 14. Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1400.00 ft' EF: 0.9 b. WA R= ft' b. Conservation features c. N/A R= ft' None 15. Credits Patel I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed Xsed on installed Code cc ian atures. Builder Signature: Date: % 22 t D Address of New Home: Z UVp City/FL Zip: 72t?f-�r �( 'Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the Department of Community Affairs at (850) 487-1824. "Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. P EnergyGauge® USA - FlaRes2008 oui cn -s, Project Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 77246"799 Fat 772-466-6796 Email: OUICKCALCS@A.OL.COM Project• • Job: Date: By: For., OWENS RESIDENCE pp3 �rz COPY! + Design Information Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TO 28 OF Heating Summary Structure 12282 Btuh CCentral vent (92 cfm) 2817 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 15098 Btuh Infiltration Fort Pierce, FL, US Method Simplified Construction quality Average Fireplaces 0 Area (ft2) He 1400 Co 1400 Volume (fta) Air changes/hour 12645 0.45 12645 0.23 Equiv. AVF (cfm) 95 48 Heating Equipment Summary Make Trane Trade XR14 Weathertron Model 4TWR4030A1 ARI ref no. 578934 Efficiency 8.4 HSPF Heating Input Heating output 26200 Btuh @ 47°F Temperature rise 0 OF Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Space thermostat Printout certified by ACCA to meet all Summer Design Conditions Outside db Inside db 90 75 OF OF Design TD Daily range Relative humidity 15 L 50 OF % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 19664 Btuh Ducts 0 Btuh Central vent (92 cfm) 1509 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 20114 Btuh Latent Cooling Equipment Load Sizing Structure 3425 Btuh CCentral vent (92 cfm) 3823 Btuh Equipment latent load 7248 Btuh Equipment total load Req. total capacity at 0.70 SHR 27363 2.4 Btuh ton Cooling Equipment Summary Make Trane Trade XR14 Weathertron Cond 4TWR403OAl Coil 4TEE3F37A1 ARI ref no. 578934 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio of Manual J 8th Ed. 14 SEER 20580 Btuh 8820 Btuh 29400 Btuh 980 cfm 0.050 cfm/Btuh 0 in H2O 0.74 ' 1 •' wrighttsoTt' Right -Suite® Universal 7.1.08 RSU08101 2010Jul-0609:19:39 Ar+CA C:1Documents and SettingMikki 21My DooumentslWrigtnsott HVAC10WENS RESIDENCE.mp Cale= MJ8 0 Page 1 a1nG ^� Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-4666796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 3 2 Exposed wall 155.9 It 27.0 ft 3 Ceiling height 9.0 It ci 9.0 it heat/Cool 4 Room dimensions 1.0 x 174.0 ft 5 Room area 1405.0 ft' 174.0 IF Ty Constnlction U-value Or HTM Area (III Lead Area (" Load number (Btuh/ft�*F) (Btuh/fP) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat I Cool Gross I N/P/S Heat Cool Gross NIP/S Heal Cool 6 VN 13A-7.5ocs 0.095 n 2.66 : 1.50 369 354 -" 942 '531 117 ' -. 117 311 176 �G 1Aclom .. 1.270 n ..35.56' 34.77 15 0 .: 533-. •522 •0 0 0 0 V)/ 13A-7.5acs 0.095 a 2.66 1,50 333 303 806 455 126 111 295 167 Y-C tAclom 1.270 a 35.66 91.12 30 0 1067 2734 15 0 533 1367 11 VN I. 13A7.5ocs 0.095 s 266 1.50 369 333 886 500 0 .0 0 0 FL- IA-dtom. 1.270 s 135.56 34.77 15 15 533 - 522 - 0 0 0 0 11DO 0.390 s` •10.92 11.31 21. 21 229 236 -0 0. 0 0 lQ/ 13A-7.5ocs 0.096 w 2.66 1.50 333 282 750 423 0 0 0 0 �C 1Aclom 1.270 w 35.56 91.12 30 0 1067 2734 0 0 0 0 �D 11 D0 0.390 w 10.92 - 11.31 21 21 229 238 0 0 0 0 'C' 16B-30ad 0.032 - 0.90 1:68 1405 1405 11259 2360 "174 174 156 292 F k 21A-20c 0.027 - 0.76 0.00 1405 1405 1062 0 174 174 132 0 6 C)AED excursion 0 -14 Envelope losstgain 9364 11255 1427 1987 12 a) Infiltration 2918 799 505 138 b) Roornventilation 0 0 0 0 13 Internal gains: O=pants @ 230 7 1610 0 0 Appliances@ 1200 5 6000 0 0 Subtotal (lines 6 to 13) 12282 19664 1932 2125 Less external load 0 0 0 0 as transfer 0 0 0 0 Redistribution 0 0 15 14 14 Subtotal 12282 19664 1948 2140 15 Ductloads 0% 0% 0 0 0% 0% 0 0 Total room load 12282 19664 1948 2140 Air required (cfm) 0 980 0 107 ?9+-Right-Suite® Universal 7.1.08 RSUD8101 C1Documehts and Settings%lkki 21My Documents\Wrightsoft HVAC1OWENS RESIDENCE.rup Cale =MJ8 O 2010-Jul-08 09:19:40 Page 1 QU1-. ca �cs, urr. I RighW@ Worksheet Date: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 7724666799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 2 Exposed wall 9.0 it 27.0 ft 3 Ceiling height 9.0 it heat/000l 9.0 It heat/000l 4 Room dimensions 9.0 x 9.0 it 1.0 x 174.0 it 5 Room area 81.0 fF 174.0 fF Ty Construction U-value Or HTM Area (112) Load Area (ft2) Load number (Btuh/ftx"F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool fi 4N a ,13A7.5ocs 0.095 n 2.66 - 1.50 0 0 0 0 " 0 0 0 •0 I-G 1A- l onn 1.270 n 35.56 . 34.77 0 '. 0 0 '0 0 0 0 0 W 13A-7.5ocs 0.095 a 2.66 1.50 81 81 216 122 126 111 295 167 I--G 1Aclom 1.270 a 35.56 91.12 0 0 0 0 15 0 533 1367 11 UN L. 13A-7.56cs 0.095 s 2.66 1.50 0 0 0 . 0 117 117 ". 311 176 1Aclom 1.270 5 35.56 34.77 0 0 0 0 0 0 0 0 L�DG 11D0" 0,390 s', 10.92 11.31 0 0 0 0.. 0 -0 0 0 LR✓ 13A-7.5ocs 0,095 w 2.66 1.50 0 0 0 0 0 0 0 0 I-G to-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 �D 11 D0 0,390 w 10.92 11.31 0 0 0 0 0 0 0 0 'C . 168-30ad 0.032 - 0.90 1.68 81' 81. 73 138 - 174 174 156 292 F i 21A-20c 0.027 - 0.76 0.00 81 81 61 0 174 174 132 0 6 c) AED excursion -24 -14 Envelope lossigain 349 234 1427 1987 12 a) Infiltration 168 46 505 138 b) ',Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances@ 1200 0 0 0 0 Subtotal (lines 6 to 13) 518 280 1932 2125 Less external load 0 0 0 0 Less transfer o 0 0 0 Redistribution 23 21 15 14 14 Subtotal 540 301 1948 2140 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 540 301 1948 2140 Air required (cm) 0 15 0 107 -pj+- wrogr.csorc- Right -Suite® Universal 7.1.08 RSUC8101 C.Mocuments and SettingsWikki_2Wy Documents\Wrightsoft HVAC\OWENS RESIDENCE.wp Celc=MJ8 0 2010Jul-06 09:19:40 Page 2 99== Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE. FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name BEDROOM 4 KITCHEN 2 Exposed wall 15.0 ft 13.0 ft 3 Ceiling height 9.0 ft heat/cool 9.0 It heaticool 4 Room dimensions 1.0 x 171.0 ft 12.0 x 13.0 ft 5 Room area 171.0 ft 156.0 fN Ty Construction U-value Or HTM Area (ft2) Load Area (fly Load number (Btuh/fti°F) (Btuh/fl2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 13A-7.50cs 0.095 n '.2.66 1.50 135 120 : - 319 180 - 0' - 0 0. L-G 1Ac1om 1.270 n. 35.56 34.77 15 0 .. 533 - 522 0. 0 0'. 0 lR/ 13A-7.5ocs ' 0.095 e 2.66 1.50 0 0 0 0 0 0 0 0 LG 1Aclom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 11 W 1 13A-Z5ocs. 0.095 s 266 1.50 0 0 0 0 117 81 215 122 IL-�G tA- lom' 1.270 s 35.56 34.77 0 0 0 0 15 15 533 = 522 11D0' 0.390 s ,10.92 11.31 0 0 0 0 '21 '21 229 238 V+J 13A-7.5ocs 0.095 w 2.66 1.50 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 11 D0 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0 C 1" 16B-30ad 0.032 0.90 1.68 171 171 '153 287 ;- 156 156. 140 262 F 21A-20c 0.027 -, 0.76 0.00 171 171 129 0 156 . 156 118 0 6 c) AED excursion -230 -202 Envelope lossigain 1135 759 1236 940 12 a) Infiltration 281 77 243 67 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 3 690 0 0 Appliances @ 1200 1 1200 2 2400 Subtotal (lines 6 to 13) 1416 2726 1479 3407 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 D 0 0 14 Subtotal 1416 2726 1479 3407 15 Dud loads 0% 0% 0 0 0% 0% 0 0 Total room load 1416 2726 1479 3407 Air required (cfm) 0 136 0 170 G - 1} .,..��a'+tsesr RightSuile® Universe] 7.1.08 RSUC8101 AccA C:\Documems and Saltings\Nikki_2Wy Documems\Wrightsofi HVAC\OWENS RESIDENCE.rup Celc-MJ8 0 2016Jul-06 09:19:40 AS Page 3 cane ,xc. RighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name GREEAT ROOM WIC 2 Exposed wall 4.0 It 7.0 It 3 Ceiling height 9.0 It heat/cool 9.0 It heat/000l 4 Room dimensions 1.0 x 205.5 It 6.0 x 7.0 It 5 Room area 205.5 ft- 42.0 fl' ' Ty Construction U-value Or HTM Area (ft2) Load Area UP) Load number (Btuh/ftMF) (Btuh/R-) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heal I Cool Gross NIP/S Heat Cool Gross WP/S Heat Cool 6 13A-7.5ocs - 0.095 n 2.68 .. -1.50 0 0 0 - 0 0 0 0 - 0 �G 1AxIom, .1.270 n 35.58 34.77 0 0' 0• 0 0' - 0 0 0 13A-7.5oce 0.095 a 2.68 1.50 0 0 0 0 0 0 0 0 t-G tActom 1.270 a 3556 91.12 0 0 0 0 0 0 0 _ 0 11 1p/ i 13A-7.5ocs -0.095 s. 2.66 1.50 0' 0 0 0 63 63 168 95 1A-ctom 1.270 5 35.56 34.77 0' 0' 0 a 0' 0 0- 0 11DO 0.390 s '10.92 11.31 0 0 0 0 0. . 0' 0 0 13A-7.5ocs 0.095 w 2.66 1.50 36 15 40 23 0 0 0 0 1Aclom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 11 DO 0.390 w 10.92 11.31 21 21 229 238 0 0 0 0 C 1613-30ad 0.032 - - 0.90 1.68. 206 206 184 345 42 42 38 71 F I 21A-20c 0.027 - 0.76 0.00 206 206 155 0 42 _42 32 0 6 c)AED excursion -307 -16 Envelope loss/gain 609 298 237 149 12 a) Infiltration 75 20 131 36 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants(P 230 4 920 0 0 Appliances @ 1200 2 2400 0 0 Subtotal (lines 6 to 13) 694 3639 368 185 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 33 31 0 0 14 Subtotal 716 3689 368 185 15 Duct loads 0% 0% 0 0 0 % 0% �, 0 0 Total room load 716 3669 / 368 185 Air required (cfm) 0 183 f 0 9 -rja-....ros'.cmerr Right -Suite® Universal 7.1.08 RSU08101 C-.0ocuments and Settings%ikki_2Wy Documents\Wdghtsoft HVAC\OWENS RESIDENCE.rup Cale =MJ8 0 Page 4 Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: OUICKCALCS@AOL.COM Job: Date: By: 1 Room name M. BATH MASTER BEDROOM 2 Exposed wall 14.0 ft 21.9 It 3 Ceiling height 9.0 It heaticool 9.0 It heat/cool 4 Room dimensions 6.0 x 8.0 It 1.0 x 220.5 ft 5 Room area 48.0 112 220.5 ft ' Ty Construction U-value Or HTM Area (ft2) Load Area (" Load number (Btuh/ft-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heal Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 % '13A-7.5ocs 0.095 n .' 2.66 1.50 0 0 0 0 63 63 168 95 -0 -, G 1Aclom - 1.270 n 35.55 34.77 0 0 .,, 0 0 -0. 0,, 0 VN 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 0 0 0 0 T-G 1A�1om 1.270 a 35.56 91.12 0_ 0 0 0 0 0 0 0 11 t. �pI/-� 13A-7.5ccs 0.095 -S 2.66 1.50 72 72 192 108 0. 0 0 0 1Aclonn -1.270 s 35.56 34.77 0 0 0 0 - 0 0 0 0 r-D 11D0 ' 0.390 s 10.92 11:31 0 0 0' 0 0 0 0 0 0.095 w 2.66 1.50 54 54 144 81 135 105 279 158 tO13A-7.5ocs G 1Aclom 1.270 w 35.56 91.12 0 0 0 0 30 0 1067 2734 11DO 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0 C 16B-30ad. (.032 - '0.90 1.68 48 - 48 43 81 221. 221 .. 198 370 F 21A-20c 0,027 - 0.76 0.00 48 48 36 0 221 221 167 0 6 c)AED excursion -27 878 Envelope losstgain 414 243 1878 4234 12 a) Infiltration 262 72 412 113 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 676 315 2290 4347 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 676 315 2290 4347 1151 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 676 31-9 2290 4347 Air required (chn) 0 16 0 217 '4ft'-Fi- sg'asorFe- Right -Suite® Universal 7.1.08 RSU08101 2010Jul-0609:19:40 CADocuments and SeaingsWikki_21My Dowments\Wrightsoft HVAC\OWENS RESIDENCE.mp Cale =MJ8 0 Page QrncxcnL s,TNa Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34M Phone: 772-466-6799 Fa[ 772-466-6796 Email: QUICKCALCS@AOLCOM 1 Room name UTILITY HALL 2 Exposed wall 18.0 ft 0 ft 3 Ceiling height 9.0 It heaVcool 9.0 ft heat/000l 4 Room dimensions 1.0 x 81.0 ft 13.0 x 4.0 ft 5 Room area 81.0 ft2 52.0 ft2 ' Ty Construction U-value Or HTM Area (ft9 Load Area (ft2) Load number (Btuh/ft--F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heal Cool Gross WPIS Heat Cool Gross WPIS Heat Cool 6 W/ 13A-7.50cs 0.095 n 2.66 1.50 54 54 144 81 0 0 0 0 L--G 1A-clorn .. 1.270 n 35.56 ; 34.77 0 - 0 0 0 0 .. 0 0 0 VN 13A-7.5ors 0.095 a 2.66 1.50 0 0 0 0 0 0 0 0 --G IAclom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 11 1p/ 13A-7.5ocs 0.095 s 2.66 1.50 0 0 0 0 0 0 0 0 I-G 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 L--D 11DO 0.390 S 10.92 11.31 0 0 0 0 0 0. 0 0 VV 13A-7.5ocs 0.095 w 2.66 1.50 108 108 287 162 0 0 0 0 �G LD 1Aclom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 11DO 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0 C' 16S-30ad 0.032 - 0.90 1.68 81 81, 73 136 52 52 47 87 F 21A-20c 0.027 - 0.76 0.00 81 81 61 0 52 52 39 0 / 6 o)AED excursion -37 -7 Envelope loss/gain 565 343 86 81 12 a) Infiltration 337 92 0 0 b) Roomvenblation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 901 435 1 86 81 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -86 -81 14 Subtotal 901 435 0 0 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room loatl 901 435 0 0 Airr red (cfm) 0 22 0 0 Printout certified by ACCA to meet all requirements of Manual J Sth Ed. G �{+-wrayr.esorr RightSufteO Universal 7.1.08 RSU08101 20104uI-0609:19:40 C:1Documems and SettingsWikk12N1y DoamentslWrightsoft HVAC10WENS RESIDENCE.rup Calc=M.18 0 Page