HomeMy WebLinkAboutBUILDING SITE PLANS//10I4V IV PROJECT DESIGN A 7/16/2009 JURISDICTION Saint Lucie County, FL ndm nts CODE e e PROJECT NAME IFB# 17 St. Lucie County -Owens Residence PROJECTADDRESS 2403 St. Lucie Blvd. Fort Pierce, Florida 34946 ARCHITECTIENGINEER HARVEYE. KOEHNEN, PE 32831 7205 ELYSE CIRCLE PORT ST. LUCIE, FL 34952-8212 TYPE OF CONSTRUCTION VB WIND SPEED (3 Sec Gust) 140 MPH EXPOSURE B INTERNAL PRESSURE COEFFICIENT 0.18 IMPORTANCE FACTOR 1.0 BUILDING CATEGORY ENCLOSED II MEAN BUILDING HEIGHT- 16 11' -10 1/4" OVERHANG V-4" MAX ROOF PITCH 5/12 COMPONENTS & CLADDING WIND PRESSURES See Elevations ROOF DEAD LOAD 17 ROOF LIVE LOAD 20 FLOOR LIVE LOAD N/A SHUTTERS No IMPACT RESISTANT ASSEMBLY Yes 9,410,# 11,#12 7/20/2010 1. AS PER TABLE R301.2(1) OF THE 2007 FBC WEATHERING IS NEGLIGIBLE AND TERMITE AREAS ARE VERY HEAVY 2. ALL WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF NOT GREATER THAN 200 AND SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450 AS PER FBC CODE R315 3. ALL INSULATION MATERIALS SHALL HAVE A FLAME SPREAD NOT TO EXCEED 25, WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450, AND A CRITICAL RADIANT FLUX NOT LESS THAN .12 WATT PER SQ. CENTIMETER AS PER 2007 FBC CODE R316 4. ALL GYPSUM BOARD TO CONFORM TO STANDARDS SET IN 2007 FBC CODE R702.3.1 5. ALL TILE SETTING IN SHOWER/TUB STALLS SHALL BE CEMENT, FIBER -CEMENT, OR GLASS MAT DRYWALL CONFORMING TO 2007 FBC CODE R702.4.2 5 LEFT SID 5 ELEVATION SCALE: Y4"=1'-0" RIGHT SIDE ELEVATION SCALE: W'=V-0" 5 REAR ELEVATION SCALE: Y4"=1'-0" TERMITE TREATMENT REQUIRED 5 +35.3 38.2 +35.3 38.2 E10. FRONT ELEVATION SCALE: Y4"=1'-0" I r 11 #1 7/1812010 ST. LUCIE COUNTY BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT G PERMIT: BUILDING A DDRESS: 2403 St, Lucie Blvd., Foil Pierce, FL CONTRACTOR: OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS & SKYLIGHTS OPENING& MI MANUFACTURER GLASS ATTACHMENT METHOD NOANo.& EXPIRATION PRODUCTDESIGN PRODUCE DESCRIPTION TYPE, SIZE, SPACING &EMBEDMENT PRESSURE DATE 1/4" Dia Tapcon w/ min Embedment of 25 SH Low-E Window SH-700 FIST Industries Hi -Impact 1-3/8" into conc, Thru predrill mfg. 7-0322.06 +80.0 holes 6/7/2011 -80.0 Distinction 1/4" Dia Tapcon w/ min Embedment of New 3068 Ext Door Series Plastpro, Inc. Hi -Impact 1-3/8" into conc. Thru predrill mfg. FL 7241.1 +50.0 holes (6) into jambs & (2) into header •50.0 New 3068 Ext. Low-E Fr. Fiber 1/T Dia Tapcon w/ min Embedment of Door Glass Plastpro, Inc. I HI -Impact 1-318" Into conc. Thru predrill mfg. FL 12059.1 +48/1 Door holes (6) into jambs & (2) into header PRODUCT MODEL # MANUFACTURER ATTACHMENT METHOD NOA No. & PRODUCT IGN F TYPE, SIZE, SPACING EMBEDMENT & STIFENER ETC. EXPIRATION PRESSURE DATE 3 Tab Shingles Gaf Materials (6) Roofing nails into ea. Shingle w/ min 3/16" penatration thru roof decking FL 10124-R2 N/A I have reviewed the above and approve it. (Enigneer of Record) NAME,: SIGNATURE: CERTIFICATION NO: DATE:_ V 7'-4° 18,-0" -1 1'-4" 25 S.H. 25 S.H. EGRESS EGRESS ------------ 11'-741 2' 441" 8'-4a' 24j' w I� co BEDROOM #3 ' U 'n F •� o BEDROOM #2 8'-0" CEILING �I _ N W-0" CEILING O Co N � W i N �T v 2868 oU I 20 00 00 0 00 1 00 00 00 � N M N --------- i O C> D ---- �-) ----, IN 11'-7(' 13'-1C — -J I I 42" TALL KNEE WALL or BEDROOM #4 I s'-o" CEILING GIEEAT ROOM KITCHEN 0" EILING --'I' 8'-0" CEILI 1G of i w 12" WIDE i co o O v=S w i COUNTER TOP 'n i � I N w I 8'-21" 3'-4j" 25'-01j'P I N 6068 3'-5" 17'-0" 1 I = Ui • In N N 12" R&S A.H.U. 12" R&S i- UTILITY #00 — 8'-0" CEILING 718/2 00 o n 2 00 8'-0 ; •EILI U10) A 0 DRYER ASH ACCE _. 11 „ 4'-71" 14'-41 I 6' i0#" ------- ---- n ---------- i EGRESS 12" R&S DRYER VENT i 2'-0" MASTER #5 ;; 7/18/2011Yi BEDROOM° 8'-0"00 CEILING PORCH CEILINGS TO BE STUCCO OVER WIRE LATH W./ 11 GA 2" LONG NAILS W/ 3/" DIA. HEAD 0 6" O.C. OVER 3/a" METAL RIB LATH0000 •I W/ (2) LAYERS OF 30# FELT ---- ----- _ 1 7/18/10 .... --------- --------- 15'-7" 4'-5" (2) 2 S.H. EGRESS 6'-8" FLOOR PLAN SCALE: Y4"=1'-0" THFUE PLIMS HAVE MEN RNI i UYI LDINME THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLIGARLF GODS, AREA SCHEDULE LIVING AREA 1,400 Sq Ft. FRONT PORCH 139 Sq Ft. TOTAL 1,539 Sq Ft. ATTIC VENTING CALCULATIONS CEILING = 1539 SO. FT. 1539/150 = 10.26 SQ. FT VENTILATION REQUIRED SOFFIT VENTING 15 SQ. IIJ.x158 LINEAR FEET=16.4 SQ. FT. VV / _ VUor ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR C ANCE REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE SCANNED BY St Lucie CDu W M U Q z o O (n J W U. W U U W W >Z 0— O� �O Z LL Z) O� U > W J 00 U W U � J r v) z co W W O LL- N O U � •0 o L O c O_ .J O Date 4/21/2010 Issue H.K. Drwg By J.D. File Sheet LA1_j PROJECT DESIGN DATA 1 7/16/20091 JURISDICTION City of Port Saint Lucie, FL CODE FBC 2007 with 2009 Amendments PROJECT NAME IFB# 17 St. Lucie County -Owens Residence PROJECTADDRESS 2403 St. Lucie Blvd. Fort Pierce, Florida 34946 ARCHITECT/ENGINEER HARVEYE. KOEHNEN, PE 32831 7205 ELYSE CIRCLE PORT ST. LUCIE, FL 34952-8212 TYPE OF CONSTRUCTION VB WIND SPEED (3 Sec Gust) 140 MPH _ EXPOSURE B INTERNAL PRESSURE COEFFICIENT U. �0.18 IMPORTANCE FACTOR 1.0 BUILDING CATEGORY ENCLOSED II MEAN BUILDING HEIGHT-16 11'-101/4" OVERHANG 1' - 4" MAX ROOF PITCH 5/12 COMPONENTS & CLADDING WIND PRESSURES See Elevations ROOF DEAD LOAD 17 ROOF LIVE LOAD 20 FLOOR LNE LOAD N/A - SHUTTERS No IMPACT RESISTANT ASSEMBLY Yes 0 1 CITY OF PORT ST. LUCIE BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT BUILDING PERMIT: BUILDING DDRESS:2403 St. Luc'Blvd., Fort Pierce, FIL CONTRACTOR: OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS & SKYLIGHTS' OPENING& MODEL # MANUFACTURER GLASS ATTACHMENT METHOD NOANo.'& EXPIRATION PRODUCT DESIGN PRODUCE DESCRIPTION TYPE, SIZE, SPACING &EMBEDMENT PRESSURE DATE 1/4" Die Tepcon w/ min Embedment of 26 SH Low-E Window SH 700 PGT Industries Hi -Impact 1-3/8" into cone, Thtu predrill mfg, 7-0322,06 +80.0 holes 6f7/2011 -80.0 Distinction 1/4" Dia Tapeon w/ min Embedment of New 3068 Ezt Door Series Plastpro, Inc. Hi -Impact 1-3/8" into cone: Thru predrill mfg. FL 7241.1 +500 holes (6) into jambs & (2) Into header .50.0 New 3068 EA. Low-E Fr. Fiber 1/4" Die Tepcon w/ min Embedment of Door Glass Plastpro, Inc. HI-Impaci 1-3/8" Into cone, Thru predrill mig. FL 12059.1 +481-51 Door I I holes (6) into jambs & (2) Into header PRODUCT MODEL # MANUFACTURER ATTACHMENT METHOD NOANo. & EXPIRATION PRODUCTDESIGN TYPE, SIZE, ; EMBEDMENT &STIFFENER ETC, PRESSURE DATE. DATE 3 Tab Shingles g Gaf Materials (6) Roofing na s into ea. Shingle w/ min 3/16" penetration FL 10124-R2 N/A thru roof decking have reviewed the above and approve it. (Enigneer of Record) _ NAME: R@; SK3NATU CERTIFICATIONNO: DATE: {W—Rl, 7'-4" 25 S.H. 25 S.H. EGRESS EGRESS 1V-74" 2' I 14I" I 8'-4I' I 2'-44I' I 1 .._ I z- i to I F W % m BEDROOM #3 I � , ..-.-.-. I BEDROOM #2 N8'-0" CEILING C41-I N 8'-0" CEILING I N �w � � Ip 2 I vN Zt68 ro I co = cc rD 00 io co I ih i� W_________ 0 i ij 11 11' N 42" TALL I KNEE WALL Li BEDROOM ##4 C AT ROOM r I' Ill - I t - KITCHEN 8'-0" CEILING i 8 '0 CEILING 8'-0" CEILING in I 12" WIDE I � - 0 �w i.: 1 COUNTER TOP In i N N w I 8'-A 3'-4}" 25'-Of 6068 N--- 4, I E 02): V N ---------------- R/A N 12" R&S A.H.U. 12" R&S UTILITY 00 p ..___ : 8'-0" CEILING 00 1J EEo 8'-0" 'EILI din DRYER ASH N o N 11 " 4'-A 14'-41 -I 6' i01" ------- Ln ---- 3068 12" R&S DRYER i VENT 12'-0" EGRESS MASTER 0) BED— RU0 1 coco (gip 8'-0" CEIUNG x E-i w p T (. )j II --- - --------------------7----------------------- - 14'-5„ (2) 2 S.H. EGRESS 6'-8" FLOOR PLAN SCALE: Y4" =1'-0" TERMITE TREATMENT REQUIRE VEvrE P p �p�HAAVE BEEN "tikyb�-1`H;J 1H t n)iiEifg5l7fI a d OIL WIN mzsc iDE. RIGHT SIDE ELEVATION SCALE: Y4"=1'-0" 5 REAR ELEVATION SCALE: Y4"=1'-0" 5 +35.3 38.2 38.2 FRONT ELEVATION SCALE: Y4"=1'-0" THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRSOTIONs REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE Coon, FILE COPY AREA SCHEDULE LIVING AREA 1,4(l0 Sq Ft. FRONTPC 139,Sq Ft. TOTAL 1,539 Sq Ft. ATTIC VENTII� G CALCULATIONS CEILING = 1539 SO. FT. 1539/150 = 10.26 SQ. FT; VENTILATION REQUIRED SOFFIT VENTING 15 SQ. IN.058 LINEAR FEET=16.4 SQ, FT. REVISION No. Date By W U Q Z 0 00 U) W C/) U W 0- 0 O Z LL o !LJW W U W J U � J ,,. U) r— Cn Z co W LL W o N O :ilo m O c a -1 o � Date 4/21/2010 Issue H.K. Drwg By J.D. File Sheet Al SEE TYP. WALL SEC. SEE TYP. WALL SEC, FOR DETAILS FOR DETAILS #5 REBAR FOOTER W/ #5 REBAR FOOTER W/ 10" BEND IN FTR. & 10" BEND IN FTR. & MIN 25" LAP ON VERT. MIN 25" LAP ON VERT. REBAR REBAR GRADE io - N 16"02" MONO. CONC co 16"02" MONO. CONC FOOTER W/ 2500 PSI CONC FOOTER W/ 2500 PSI CONIC 12" W/ (2) CONT. #5 REBAR W/ 12" W/ (2) CONT. #5 REBAR W/ CORNER BARS 25"x25" CORNER BARS 25"x25" TYP. CBS WALL FTR CBS WALL/PORCH FTR SCALE: 3/4"=1'-0" SCALE: 3/4"=1'-0" 16%12" MONO. CONC 16%12" MONO. CONIC FOOTER W/ 2500 PSI CONC FOOTER W/ 2500 PSI CONC W/ (2) CONT. #5 REBAR W/ W/ (2) CONT. #5 REBAR W/ CORNER BARS 4 CORNER BARS 25"x25" GRADE e d IT — GRADE - d e...°< d N e da 120 2" _ TYP. THICKENED TYP. PORCH FTR EDGE FOOTER SCALE: 3/4"=1'-0" SCALE: 3/4"=1'-0" CASTCRETE PRECAST LINTEL SCHEDULE FIELD ADDED REBAR AT TOP F = FILLED WITH GROUT / U= UNFILLED /S=SOLID • 1-1/2" '--QUATr1T7-CFTEEEF- ADDED REBAR AT BOTTOM OF LINTEL ., C.M.U. BOND BEAM w BLOCK a z FIADADD®RB3ARAT $F�G-�B��T r, G BOTTOM NOMINAL WIDTL-2 1301IUM K-MURAM-; NOMINAL HEIGHT— �. QUANTITY OF FIELD PROVIDED IN ADDEDREBARATTOP LENGTH COMPOSITE BEAM SAFE GRAVITY APPLIED GRAVITY SAFE UPLIFT LOAD APPLIED UPLIFT 1 1 4'4" 8FR141B/1T 5206 <1000 2635 <500 2 7'-6" BF161611T 2661 <1000 1634 <500 3 4'-0" 8F16 1B/1T 6113 <1000 3079 <500 4 4'-4" 8FR1418/1T 5206 <1000 2635 <500 5 4'-6" 8F161B/1T 6113 <1000 2724 <500 6 4'-6" SF161B/1T 6113 <1000 2724 <500 7 4'-6" 8F16 16/1T 6113 1 <1000 2724 <500 co I 0 co N I Ln 71 a FILE COPY THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODE$. TROCE PUNS FAQ EEEN R Rk 51D 36'-8 1 7'-04" v 3'-10i" 7'-51" �L_- --- 6'-8" � 3'-101" 7'-9 ------------------ -------- - - - - - - - - - - - - I I I � I I i I I I . I I I I I I I I TERMITE TREATMENT REQUIRED I I , I , 1 , 1 , I 1. 1 , 1 4" CONC SLAB W,/ 2500 PSI I FIBERMESH CONC. OVER 6 MIL I VISQUEN LAPPED 6" OVER CLEAN I I COMPACTED, TO 98% DENSITY, FILL l I - , ------------- I I , I , I I I ,! I , I , I , I , I , I , ® I I , I , I 0 I 6'-0" 10 1 - 4" B.F.F.E I \ I I 10 IU-) I L----------------------- ------ — — 7'-11" J, 6' `10" 6' 4" 15-7" 1 21'-1 N Q ro a� �ol I I m I -- N co I 7 I 00 FOUNDATION PLAN SCALE: Y4"=1'-0" REVISION W w E W U Q Z O U) J W V— w U) U W cj� Z W 0- 0 F-- O Z L! D 06 U w J - m U w U UJ �- U) z M m O LL N O U 0 � ° 0 'O O 0 L. � C 3 d � O A �n Date 4/25/2010 Issue H.K. Drwg By J.D. File Sheet S1 REVISION No, Date By 2 x 4 PT SURROUND UNLESS OTHERWISE SPECIFIED, SECURE SOLID POUR CMU. (STL PER PLAN) WINDOW FRAME TO SOLID POUR CMU 3116" TAP CONS, MIN EMD 1 tl4".FILL MFGFG . I/2" DRYWALL PRE PUNCHED HOLES. WINDOW FRAME CMU WALL / SASH STUCCO - IX3 PT BUCK, TOP AND SIDES, FASTEN TO SOLD) POUR CMU W/ CASE HARDENED NAILS Q 4" OC. BUCK TO BE EQUAL IN WIDTH OR WIDER THAN THE WINDOW FRAME THAT IT SECURES. WINDOW BUCK DETAIL 8/8" x 1 5/8" BRICKMOLD DOOR JAMB PUSHED -IN ' 2"X 4" F.T. (ACT: 4 I/S") 5J0"X 1 5/S" BRICKMOLD I DCOR JAMB PULLED CUT - INSULATION 2"X4" p;T. 2"X6" P:T: 4-, (ACT: d Iva") f � o L 1� 0 0 HEADER DETAIL. FOR EXTERIOR OUT611ING DOORS NOTE, SAME DETAIL FOR JAMBS HEADER DETAIL FOR. EXTERIOR OUT15WING DOORS NOTE: SAME AS DETAIL FOR JAMBS INSULATION 2"X4" P.T. ASPHALT SHINGLE ATTACHED AS PER MFG. ,S OVER (1) LAYER OF 30 LB FELT OVER 12 i 2" PLYWOOD FASTENED TO ROOF TRUSSES 5 W/ 8d RINGSHANKS NAILS ® 6" O.C. METAL STRAP SEE SCHEDULE ON SHEET S1 MTL. DRIP EDGE R-30 BATT INSUL. P.T.1 "x2" FASCIA �8 DRYWALL 2"x6" SUB 2"x2" TOP CORD FASCIA VENTED VINYL DBL. BM. BLOCK W/ (1) SOFFIT #5 CONT REBAR W/ STUCCO CORNER BENDS EA. COURSE IN 3000 PSI CONC. #5 VERT. REBAR W/ 10" BEND IN TOP COURSE IN FILLED CBS CELL W/ 3000 PSI CONC. SEE FOUNDATION PLAN FOR SPACING 2" THICK R-8 BATT PLUS INSULATION 1 2%2"" FURRING STRIPS @ 24" O.C. (TYP.) ALL NON CONC. FILLED CELLS TO BE FILLED '4/ R-11 INJECTED FOAM INSULATION Y2" DRYWALL SEE FOOTER DETAIL FOR FOOTER STEEL SPECS WD BASE GRADE it3 N 16%12" MONO. CONC 41FOOTER W/ 3000 PSI 12" CONC W/ (2) CONT. #5 REBAR W/ CORNER BENDS TYP. WALL SECTION SCALE: %"=1'-0" TYPICAL WALL. SECTION FOR ROOF DETAILS DBL 2"x12" WD, BEAM GLUED AND SCREWED W/ # 10x3" LONG WD SCREWS 0 12" O.C. STAGGARD DBL P.T. 2"xl2" W/ Y2" PLYWOOD PITCH WD. BEAM GLUED & SCREWED W/ #10x3" LONG WD SCREWS ® 12" O.C. STAGGERED METAL STRAP SEE STRAP SCHEDULE 5"x6" P.T. WD. POST METAL ATTACHMENT SEE STRAP SCHEDULE FOR DETAILS I THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. SEE TYPICAL WALL SECTION FOR ROOF DETAILS [DEL P.T. 2-02" W/ Y2" PLYWOOD PITCH WD. BEAM GLUED & SCREWED W/ #10x3" LONG WD DBL. BM. BLOCK SCREWS O 12" O.C. STAGGERED METAL STRAP SEE STRAP SCHEDULE WD. BEAM/CBSWALL DET . E TERMIT TREATMENT REQUIRED TYP. PORCH SECTION SCALE: 3/4"=1'-0" SCALE: 3/4"=1'-0" HIM WAS HAVE BEEN REMNED IN INVIDANCE MTH THE FLORIDA MUM CODE. FILE COPY CONNECTOR SCHEDULE Simpson Date: 5/4/2010 Notes: j1) Truss to block connections are mark W unless otherwise noted on layout. Contractor: B lackstreet l _ ! (2) Roof truss to frame connections are with mark'Y' unless otherwise noted on layout. Owner: Truss Mfgr: T.J. Truss Layout Date: 428/2010 Engr. Dale: 4128/2010 TRUSS BRNO QTYCONNECTOR ID FASTENERS CONNECTED rl-d TtTi ;ACTUAL ALLOW RETAARKS 0 PT. . 1 UPLIFT UPLIFT A 1 FIETAL 20 (14) 10d x 1-1/2 1 Fly to Tie Beam 1810 V 1 ABU66 (12) 16d & (1) 5/8" x6" Titan HD Post to Slab 1800 (14)SDS 1/4"x2-1/2" SDS Screw s Into Post &(6) W 1 HJCQ410-SDS 1/4"0-1/2" SDS Screw s Into Wd, Beam Beam to 6"x6" P.T. Post 2510 (14) SDS 114"x2-1/2" Tapcons Into Cone, & (6) '.. X 1 HJCQ410-SDS 1/4"x2.1/2" SDS Screw a Into Wd, Beam Beemto Conc. Wall 2510 Y 1 MTS12 (14) 10dxl 1/2" Truss to Top Rate 860 Z 2 MTS12 (14) 10dx1 1/2" Each I Truss to Top Rate 1720 CC 2 HTS20 (24) 10d x 1-W Each Truss to Wk. Beam ; 2490 36'8" 5/12 (y) to f` r- r- r- t— r— I- � 0 I,- 1` h t•. tr) M r- ✓j U U U W W W W W W W W W W W W W U U U BEAMS BY OTHERS o 5/12 A CJ1 CJ3 CJ5 CJ5 CJ3 CJ1 I WIt W U Q Z 0 0 0 (n .J �W/ U- L_I_ t t j U U W Z W CL ® F�--,/ LL I" Z� 0p U W W U W U UJ r� U) rn Z C) W O U' N 0 c O U L e' 0 s c 0 3 0. J O Date 4/25/2010 Issue H.K. Drwg By J.D. File Sheet S 2___, ELECTRICAL FIXTURE SCHEDULE LIGHT FIXTURE '_ FAN/LIGHT FIXTURE RC ARC FAULT RECEPTICLE �GFI GROUND FAULT REC PTICAL (fl>u p TTTT ,�,� WEATHER PROOF RECEPTICALE DUPLEX RECEPT. T DEDICATED SINGLE RECEPT. If 220 RECEPT. SINGLE POLE SWITCH ® EXHAUST FAN ® 220V DIRECT WIRE A _ PHONE ` RECESSED LIGHT FIXTURE SD SMOKE DETECTOR W/ CARBON FIXTURE W WRAP PVC Nipple with (2) 4/0 AL (1) 2/0 AL 120/240 Volt 1 � — 3W 200 AMP 30 Circ. with Main Breaker FILE 0"'OPY 'ESE I�I,�S NAME' F:ro ",C� DANCEVKHT9 : �e n 5 ONG CODE, THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODE6. A/C Condenser E.W.H Disconnect Disconn( #4 Copper Wire Ground to Footing Steel Copper Water Pipe, and Ground Rod ELECTRICAL SERVICE I 1 ELECTRICAL PLAN SCALE: Y4"=1'-0" d' W M U Q z o 00 C) J L.L NWN fy f'' U) U W Z W 0— O� Q Z Z ^ O> W _j W U W U U) CO V) Z � o m � N O � c o Up � c 3 a_ -j O QR� N M = N ro h u e YtsLL7 �W amm >gW Q10 jiv R�V 8 Date 4/26/2010 Issue H.K. Drwg By J.D. File Sheet m 1 PROJECT DESIGN DATA 7/1612009 JURISDICTION _ City of Port Saint Lucie, FL CODE FBC 2007 with 2009 Amendments PROJECT NAME IFB# 17 St. Lucie County -Owens Residence PROJECTADDRESS 2403 St. Lucie Blvd: Fort Pierce, Florida 34946 ARCHITECT/ENGINEER HARVEY E. KOEHNEN, PE 32831 7205 ELYSE CIRCLE PORT ST. LUCIE, FL 34952-8212 TYPE OF CONSTRUCTION VB WIND SPEED (3„Sec Gust) 140 MPH EXPOSURE B INTERNAL PRESSURE COEFFICIENT 0.18 IMPORTANCE FACTOR 1.0 BUILDING CATEGORY ENCLOSED II MEAN BUILDING I]EIGHT - 16 1 V - 10 1/4" OVERHANG 1' - 4" MAX ROOF ITCH 5112 COMPONENTS & CLADDING WIND PRESSURES See Elevations ROOF DEAD LOAD 17 ROOF LIVE LOAD 20 FLOOR LIVE LOAD N/A SHUTTERS No It IMPACT RESISTANT ASSEMBLY Yes 9 LEFT SIDE ELEVATION SCALE: )/4`-V-0" i.7 REAR ELEVATION §CALF: �/4"=1'-0" FRONT ELEVATION +33.7 —36.7 61 C CITY OF PORT $T. LUCIE [#LIILDING 1)EPART'M ENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT RLgLDIN(i I'F:RM11': IIUILDING \DDRGSS: _lU; St. I ilcic Blvd- Fort Pierce, 11 iCt)N1'R;\('rOR: OPENING SCHEDULE: SWING DOORS, OVERI IEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS & SKYLIGIITs j OPENING& MODEL # MANUFACTURER GLASS ATTAC HMENT METHOD NOANo.& EXPIRATION PRODUCT DESIGN PRODUCE DESCRIPTION TYPE, SIZE, SPACING & EMBEDMENT PRESSURE DATE — — 1/4" Dia Tapcon w/ min Embedment of 25 SH Low-E Window SH-700 PGT Industries Hi -Impact 1-3/8" into cone. Thru predrill mfg. +80.0 holes/7/ 6/7/1 2010.0 $22.06 Distinction 1/4" Dia Tapcon w/ min Embedment of New 3068 Ex1 Door Series Plastpro, Inc. Hi -Impact 1-318" into cone. Thru predrill mfg. FL 7241.1 + 0 hobs (6) into jambs & (2) into header 600.0 New 3068 EA. Low-E Fr. Fiber 1/4" Dia Tapcon w/ min Embedment of Door Glass Plastpro, Inc. Hi -Impact 1.3/8" into cone. Thru predrill mfg. FL 12059.1 +481-51 Door I holes (6) into jambs & (2) into header PRODUCT MODEL # MANUFACTURER ATTACHMENT METHOD ANo. EXPIRATION pRODUCTDESIGN TYPE, SIZE, SPACING EMBEDMENT & STIFFENER ETC. PRESSURE ' DATE (6) Roofing nails into ea. Shingle wl min 3/16" penetration 3 Tab Shingles 9 Gal Materials thru roof decking FL 10124-112 N/A have rr� iewcd the above anJ apprm a rt. (L'nienea ufRecurd) NA.., I F. SIONA-I URli: n ' CERTIFICAHON'\O: DATE: oimmuIinmumnmmuuuno�onmuuuunumnununuum�Iuoui�liuunuumnnnmumluLLloonuuuuuunuumll�umnnmmo_ BEDROOM• _ M BEDROOM Cj ►��yMe 42" TALL _ o ---- BEDROOM #4 •1/ CEILING'12" 'FILING8'-0" r WIDE COUNTER OP r rM UTILITY8'-0" CEILING AM oimi� uununnmumoinmunumnnnnnunnuo 0- : DREGRESS • 0 r ■ ouummumuu.muunnuumnmo ouuuuuumlluuunauuno FLOOR PLAN SCALE: %4"=1'—O" THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT _Q"Alk MAY BE NECESSARY IN ORDER TO —"KP- COMPLY WITH ALL APPLICABLE CODES. SCALE: %4"=1'-0" ARFA SC1-I®LIE LIVINGARFA 1400 S9 R. FRLINTMFC i 139 § R. TOTAL 1,539 R. ATTIC VENTING CALCULATIONS CEILING = 1539 SQ. FT. 1539/150 = 10.26 SQ. FT VENIILATICN REQUIRED SOFFIT VENTING 15 SQ. IN.x158 LINEAR FEET=16.4 SQ. FT. THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. 0) •i. Uj CO 0 z O I.jj LL W C U W z w 1-O z LL 0® Uj -� m -�D W �0 r- U) z (0 W mQ U O C O p U C N C D- I Date 412112010 Issue H.K. Drwg By J.D. File Sheet Al IMPORTANT NOTES 0 _1 0 M Z W W U W J r= V NN Roof Layout: Scale: 1/4" = 1'-0" NO BACK CHARGES WITHOUT PRIOR APPROVAL FROM A REPRESENTATIVE OF TJ TRUSS CORP. 5/12 y✓� U U 0 w w w w w w w W LU w w w w c) C.) U IP BEAMS BY OTHERS 5/12 ;J 1 ;J3 ',J5 04 9 3J5 "J3 :J1 :3 FILE COPY e �EmprsPIP EEVENE,�� E�I��� �,6 C,,DANCEVVE�LOr,67 dUIIND CODE, THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALLAPPLICABLE CODES. I— ! ") TYP. END DETAIL TRUSS LAYOUT REVIEWED & APPROVED �('k WALL LEGEND 8'-0" T TJ TRUSS PROVIDES STANDARD TRUSS TO TRUSS CONNECTIONS. ALL STRAPS AND UPLIFT TIEDOWNS TO FLAT GIRDERS, BEAMS,WALLS AND JACKS ARE SUPPLIED BY THE BUILDER. DRAWN WALLS ARE BEARING UNLESS OTHERWISE NOTED. ALL UNDERFRAMING OF DROPPED CEILINGS AND FINISH FRAMING OF SPECIAL CEILINGS IS BY BUILDER. TJ TRUSS IS NOT RESPONSIBLE FOR TEMPORARY BRACING OF THE ROOF SYSTEM. FOR TEIMPORAY AND PERMANENT BRACING REQUIREMENTS SEE IBCSI 1-03 GUIDE BRACING REQUIRED BY THE INDIVIDUAL TRUSS/WEB COMPONENTS IS TO OVERCOME BENDING OF SPECIFIC COMPRESSION MEMBERS DUE TO GRAVITY OR WIND LOADS AND SHOULD NOT BE CONFUSED WITH THE BRACING REQUIREMENTS OF THE BUILDING STRUCTURE, AND SHALL BE INSTALLED BY BUILDER. TJ TRUSS DISCLAIMERS: FOR ANY CONFLICT BETWEE14 THIS SETTING PLAN AND THE INDIVIDUAL ENGINEERED DRAWINGS, THE INDIVIDUAL ENGINEERED DRAWING WILL TAKE PRECEDENCE. DO NOT CUT OR ALTER ANY TRUSS WITHOUT CONSULTING A REPRESENTATIVE OF TJ TRUSS FIRST. ANY PARTY WHO CUTS OR DAMAGES A TRUSS SHALL BE RESPONSIBLE FOR THE COST OF THE REQUIRED ENGINEERING DESIGN AND REPAIR OF THE TRUSS. NO BACK CHARGES WILL BE ACCEPTED UNLESS APPROVED IN WRITING BY AN OFFICER OF TJ TRUSS CORP. FAILURE TO SEEK THE RESOLUTION OF A PROBLEM UNTIL AFTER THE ROOF IS SHINGLED OR THE DRY WALL IS INSTALLED SHALL CONSTITUTE ACCEPTANCE OF THE PROBLEM BY THE CUSTOMER AND THE CUSTOMER SHALL BEAR TOTAL FINANCIAL RESPONSIBILTY TO RESOLVE THE PROBLEM. CUSTOMER RESPONSIBILTY: PROVIDE AND INSTALL ANY AND ALL PERMANENT BRACING REQUIRED BY THE TRUSS DESIGNS. PROVIDE A SUITABLE UNOBSTRUCTED AREA TO UNLOAD TRUSSES. TO ERECT ALL TRUSS COMPONENTS IN ACCORDANCE WITH THE TRUSS PLATE INSTITUTE PUBLICATION BCSI AND TO SEEK PROFESSIONAL. HELP AND ADVICE ON ANY QUESTIONS PRIOR TO THE ERECTION OF THE TRUSSES. FLORIDA ADM. CODE 61G15-23.002 COMPLIANCE NOTE: THIS TRUSS PLACEMNT DIAGRAM WAS NOT CREATED BY AN ENGINEER, BUT RATHER BY THE TJ TRUSS CORP STAFF AND IS PURELY TO BE USED AS AN INSTALALTION GUIDE AND DOES NOT REQUIRE A SEAL. COMPLETE TRUSS ENGINEERING AND ANALYSIS CAN BE FOUND ON THE TRUSS DESIGN DRAWINGS WHICH MAY BE SEALED BY THE TRUSS DESIGN ENGINEER. LOADING ��:RITERIA ROOF FLOOR TCLL: 20 PSF TCLL: 0 PSF TCDL: 7 PSF TCDL: 0 PSF BCLL: *10 PSF BCLL: 0 PSF BCDL: 10 PSF BCDL: 0 PSF ' = NON1ANCURRENT TOTAL LOAD: 37 PSF TOTAL LOAD: 0 PSF DUR. FACTOR: 1.25 DUR. FACTOR:1.00 CODES: FBC2007 RES / ASCE 7-05 / TPI 1-02 WIND SPEED: 140 M.P.H. BUILDING EXPOSURE: B CATEGORY: RES II WIND LOAD TYPE: MWFRS REVISIONS: r' 3. 4. APPROVAL �S NEEDED (3) WEEKS PRIOR TO (DELIVERY DATE YOUR SIGNATURE WILL ACKNOWLEDGE (1) AUTHORIZATION TO BEGIN FABRICATION (2) VERIFICATION OF DIMENSIONS PITCHES, HEEL HEIGHTS, OVERHANGS, ETC. (3) TRUSSES WILL BE BUILT IN STRICT ACCORDANCE WITH THIS LAYOUT! ❑ APPROVED -NO CHANGES ❑APPROVED AS NOTED ❑ REVISE AND RESUBMIT SIGNED DATE DELIVERY DATE DELIVERY ADDRESS: TRUSS CORP. 2801 INDUSTRIAL 33RD FT. PIERCE, FL. 34946 PH. (772) 466 - 3388 FAX (772) 466 - 9329 TOLL FREE: (1388) 326 - 3388 SPANNING THE DISTANCE -WITH PEAK PERFORMANCE MASTER # JOB # 100203 CUSTOMER BLACKSTREET ENTERPRISES LLC JOB NAME #17 ADDRESS COUNTY ST. LUCIE DATE: 4/28/10 1 DRAWN BY: RCP DF created with pdfFactory Pro trial version www.Ddffactory.com � C) 07 - Cff0Gp