Loading...
HomeMy WebLinkAboutKSM REPORTTara 19 i11I7iVL KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 R O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www,ksmengineedng.net MELBOURNE (321) 768.8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.:5693 FAX (772) 589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED March 19, 2019 KSM JOB # : 191120-1d/MH/cv PERMIT # D CONTRACTOR R & E Loader SCANNERECEIVEDBY JOB LOCATION 5903 Palm Drive St Lucie Cout ItY APR 15 2019 Fort Pierce, Florida ST. Lucie County, Permitting ITEM TESTED Compacted Foundation Fill -1st Lift TEST LOCATION DEPTH PEN DRY MAX.DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. S.W. 0 - 12" 50 108.6 111.7 97.2 2. N.W. 50 109.0 97.6 3. Center 50 108.9 97.5 4. S.E. 50 109.3 97.9 5. N.E. 50 110.0 98.5 Soil Description: Light Brown and Gray Sand In Place Moisture: 8.9 Percent Optimum Moisture: 11.0 Percent Max. Dry Density: 111.7 P.C.F. @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets 113.0 W E I I I I I H112.0 j—••_.I_.._I._..J.._..1.._..L.._.. T I IPI I111.oI IC.—..rI All IFI I110.01.. ..Li iDR iI y I 109.0.._.i_.._i._..�.._..T.._..�.._., I I I I 8 9 10 11 12 13 14 Moisture - % of Dry Weight Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 ' 1'7W -6337 rdrr1k9 " R17ltli KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM®KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED March 22, 2019 KSM JOB # : 191120-2d/SS/cv PERMIT # RECEIVED CONTRACTOR R & E Loader APR 15 2019 JOB LOCATION 5903 Palm Drive sT. Weis s4uncy, permlhing Fort Pierce, Florida ITEM TESTED Compacted Foundation Fill - 2nd and Final Lift TEST LOCATION DEPTH OF SAMPLE 1. S.E. 12" - 24" 2. S.W. " 3. Center " 4. N.W. " 5. N.E. " Soil Description: Light Brown and Gray Sand In Place Moisture: 10.1 Percent Optimum Moisture: 11.0 Percent Max. Dry Density: 111.7 P.C.F. @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets PEN DRY MAX. DRY PERCENT READ DENSITY PROCTOR VALUE COMPACTION 50+ 110.2 111.7 98.7 " 109.7 98.2 " 111.6 99.9 " 110.8 99.2 " 109.5 98.0 113.0 I I I I I W I E I I I I I I I H112.0••_.I_.._I._..J.._..1.._..L.._.. i I I I I I T IP I111.o IIFI110.0 All ' .. ..LD iR � Y I 109.0 .._. _.._ I I ._..�.._..�.._..r.._., I I 8 9 10 11 12 13 14 Moisture - % of Dry Weight Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366