Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFlorida Energy Efficiency Code For Building Construction Florida Department of Community Affairs EnergyGauge F1aCom v 2.11 FORM 40OA-2004 Whole Building Performance Method for Commercial Buildings Jurisdiction: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) Short Desc: FSCP Owner: FIRST SOURCE COMMERCE PARK Address: SOUTHKINGSHWY ST LUCIE City: ST LUCIE State: FL Zip: 0 Project: FIRST SOURCE COMMERCE PARK A-103 SoNweD PermitNo: 0 Sti• gGoU� 8 Storeys: 1 Type: Office *Conditioned Area: 482 • denotestiglAcd are . Class: Renovation to existing building *Coed + UnCond Area: 482 Does not include wall aoseclion areas Max Tonnage: 2.0 (if different, write in) Component 'Gross Energy Use LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT Compliance Summary Design Criteria Result 540.77 566.28 PASSES PASSES None Entered PASSES None Entered WATER HEATING SYSTEMS None Entered PIPING SYSTEMS None Entered ,Met all required compliance from Check List? FILE COPY Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge Com of this design building must be submitted along with this Compliance Report 3/1/06 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 1 u I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Efficiency Code. PREPARED BY: j 1� �tcffr%b�71/ DATE: 3.07• o(o I hereby certify that this building Is in compliance with the Florida Energy Efficiency Code rCIT75-5i DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be Inspected for compliance in accordance with Section 553.908, F.S. BUILDING OFFICIAL: DATE: If required by Florida law, I hereby certify (•) that the system design is in compliance with the Florida Energy Code. ARCHITECT: dgC�j 9��fS r�tizrr� ' ELECTRICAL SYSTEM DESIGNER LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: - PLUMBING SYSTEM DESIGNER REGISTRATION No. (•} Signature is required where Florida Law requires design to be performed by registered design professlonals. Typed names and registration numbers may be used where all relevant Information Is contained on signed/sealed plans. r 03/0�/06 2/28/06 - EnergyGauge FlaCom v 2.11 FORM 400A-2004 2 Project: FSCP' Title: FIRST SOURCE COMMERCE PARK A-103 Type: Office (WEA File: DAYTONABEACELTMY) Whole Building Compliance Design Reference Total 95.12 100.00 $540.77 $566.28 ELECTRICITY(MBtulkWhl$ 95.12 100.00 10,837.00 11,417.00 $540.77 $566.28 AREA LIGHTS 16.20 14.14 1,838.00 1,624.00 $91.72 $80.55 MISC EQUIPMT 9.25 9.25 1,059.00 1,059.00 $52.84 $52.53 PUMPS & MISC 0.26 0.26 32.00 31.00 $1.60 $1.54 SPACE COOL 20.31 21.08 2,302.00 2,395.00 $114.87 $118.79 VENT FANS 49.10 55.27 5,606.00 6,308.00 $279.74 $312.88 Credits & Penalties (if any): Modified Points: = 95.12 PASSES External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/IInit) or No. of Units (W) (W) (Sgft or ft) None 3/1U06 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 Project: FSCP Title: FIRST SOURCE COMMERCE PARK A-103 Type: Office (WEA File: DAYTONABEACILTMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance 'Pt07o1Sp1 16 Office -Open Plan 482 2 6 1 PASSES PASSES Project: FSCP Title: FIRST SOURCE COMMERCE PARK A-103 Type: Office (WEA File: DAYTONABEACETMY) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System Air Cooled < 65000 BuA 10.30 10.00 10.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.80 0.90 PASSES System -Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV lance None 311106 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 Water Heater Compliance Description Design Min Design Max Comp P Type Category Eff Eff Loss Loss Hance None Piping System Category Pipe Dia b Operating Ins Cond Ins Req Ins [inches] Runoat? Temp ,[Btu-in/hr Thick [in] Thick [in] IF] SF.F1 :t: FSCP FIRST SOURCE COMMERCE PARK A-103 Office File: DAYTONABEACH.TMY) Other Required Compliance Category Section Requirement (write N/A in boa if not applicable) Check I Infiltration 406.1 Infiltration Criteria have been met �ystem 407.1 HVAC Load sizing has been performed entilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it 13 Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? 3/l/06 EnergyGange FlaCom v 2.11 FORM 40OA-2004 1 5 EnergyGauge F1aCom v 2.11 IWUT DATA REPOR Proiect Information Project Name: FSCP Orientation: North Project Title: FIRST SOURCE COMMERCE PARK A-103 Building Type: Office Address: SOUTH KINGS HWY Building Classification: Renovation to existing building ST LUCIE State: FL No.of Storeys: 1 Zip: 0 GrossArea: 482 Owner. FIRST SOURCE COMMERCE PA Zones No Acronym Description Type Area [sf] Multiplier Total Area [8f] 1 PrOZol Zone 1 CONDITIONED 482.0 1 482.0 Spaces No Acronym Description Type Depth Width Height Multi — peer— TotalArea [ilI Total Volume 3/1/06 EnergyGauge FlaCom v 2.11 1 In Zone: PrOZol 1 PrOZo1SD1 Zo0Sp1 Office -Open Plan 24.10 20.00 9.00 1 482.0 4338.0 El Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctri pts In Zone: PrOZol In Space: PrOZo1Sp1 1 Compact Fluorescent General Lighting 1 600 600 Manual On/Off 6 Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens R-Value [ft] [ft] plier [st] [Btu/trr. sf. F] Capacity [lb/cf] [b sf.FBtu] [Btu/sf.]F] In Zone: PrOZol. 1 PrOZo1Wa3 5/8" stucco 1.00 9.00 1 9.0 North 0.2067 5.7314 34.65 4.84 ❑ /8"CMU/3/4"ISO BTWN24"od.5" GYP 2 Pr0Zo1Wa4 5/8" stucco 1.00 9.00 1 9.0 South 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 Pr0Zo1Wa5 51811stucco 15.00 10.00 1 150.0 East 0.2067 5.7314 34.65 4.84 0 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4 Pr0Zo1Wa6 0.5 Ply/35/8" Mtl 1.50 10.00 1 15.0 North 0.0798 0.5388 7.98 12.54 std@24"oc/RI l/0.5" GYP 5 PrOZolWa7 0.5 Ply/35/8" Mtl 1.50 10.00 1 15.0 South 0.0798 0.5388 7.98 12.54 std@24"oc/Rl1/0.5" GYP - - 3/1/06 Ener gyGauge MaCom v 2.11 2 6 Pi0Zo1Wa8 0.5 Ply/35/8" Mtl s[d@24"oc/Rl l/0.5" GYP 15.30 10.00 1 153.0 East 0.0798 0.5388 7.98 12.54 ❑ Windows No Description Type Shaded U SHG [Btu/hr sf F] VmTr W H (Effec) Multi Total Area [ft] [ft] plier [sq] In Zone: PrOZol In Wall PrOZo1Wa5 1 PtOZo1Wa5Wi1 SINGLEREFB No 0.8785 0.23 TINT-L 0.05 8.66 9.00 1 77.9 Doors No Description Type Shaded? Width H (Effec) Multi [ft] [ft] plier Area [sf] Cond. Dens. Heat Cap. R Value [Btulhr. sf. F] pb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: In wall Roofs No Description Type Width H (Effee) Multi [ft] [ft] plier Area [sf] Tilt [deg] Cond. Heat Cap Dens. R Value [Btu/hr. Sf. F] [Btu/sf. F] Rb/cf] @.sf.F/Btu] ,In Zone: PtOZol 1 PcOZo1Rf1 Sngl Ply/2"Iso/2" Conc/Mtl Deck 20.00 24.10 1 482.0 0.00 0.1372 4.74 71.00 7.29 ❑ Skylights No Description Type — U SHGC Vis.Tran [Btu/hr sf Iq W [ftl H (Effec) Multiplier Area Total Area [rtl [sn [Sfl 3/1106 EnergyGauge FlaCom v 2.11 In Zone: In Roof: Floors No Description Type Width Ift1 H (Effec) Multi Ift] plier Area Cond. Heat Cap. Dens. R-Value [sf1 [Btu/hr. sf. F1 [Btu/sf. F1 pbkll [L.sf.F/Btul To Zone: ProZol 1 Pr0Zo1F11 Concrete floor, 20.00 carpet and rubber pad 24.10 1 482.0 0.5987 9.33 140.00 1.67 ❑ Systems Pr 0Syl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency D'LV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volmne) 23600.00 800:00 10.30 10.00 0.80 ❑ ❑ Plant Equipment Category Size Inst.No Ell. IPLV Water Heaters W-Heater Description Capacit Cap.Unit UP Rt. Efficienc Loss 3/1/06 EnergyGauge FlaCom v 2.11 4 Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sVft/No] Control Type Wattage [W] Piping No Type Operating - Insulation Temperature Conductivity [Fj [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Thickness [in] Is Runout? Fenestration Used Name Glass Type No. of Panes Glass SHGC VLT Conductance [Btu/Lsf.F] ApLbWnd4 SINGLE REF B 1 TINT-L 0.8785 0.2270 0.0500 ❑ Materials Used Mat No Acronym Description Only R-Value RValue Thickness Used [h.sf.F/Btu] [ft] Conductivity [Btu1hft.F] Density [Ib/cf] SpecificHea t 7 NW187 1158 1 Mat1151 Mat1178 GYP OR PLAS BOARD,1/2IN CONC HW, DRD, 140LB, CARPET W/RUBBER PAD No 0.4533 0.0417 No 0.4403 0.3333 Yes 1.2300 0.0920 0.7570 50.00 140.00 0.2000 0.20004n- ❑ ❑ 311106 EnerRyGauge FlaCom v 2.11 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Matl42 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 211 Maf1211 POLYSTYRENE,EXP.,1/21 No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ N, 12 Mat112 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 82 Matl82 ASPHALT -SHINGLE AND Yes 0.4400 ❑ SIDING 11 Maui 1 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 47 Matl47 2 in. Heavyweight concrete No 0.1670 0.1670 1.0000 140.00 0.2000 ❑ Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf F] pb/cf] [h.sf.FBtu] 1004 Concrete floor, carpet and ribber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 151 CONC HW, DRD, 1401B, 4IN 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8368 ❑ BTWN24"oc/.5" Gyp _ Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625" stucco 0.0521 0.00 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.00 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.00 ❑ 4 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 ❑ 311106 EnergyGauge FlaCom v 2.11 No Name Simple Construct Massless Conductance Construct (Rtu/b.sf.F] Heat Capacity [Btu/sf.F] Density Rb/cf] RValue @.sf.F/Stu] 1015 0.5 Ply/35/8" Mtl std@24"oc/Rll/0.5" Gyp No No 0.08 0.54 7.98 12.5383 ❑ Layer Material No. Material Thickness Framing [ft] Factor 1 211 POLYSTYRENE,EXP.,1/2IN, 0.0417 0.00 ❑ 2 12 3 in. Insulation 0.2500 0.00 ❑ 3 187 GYPORPLASBOARD,1/2IN 0.0417 0.00 ❑ No Name Simple Construct Massless Conductance Construct [Btu/h.sf.F] Heat Capacity [Btu/sf.F] Density Pb/cf] RValue [h.sf.F/Btu] 1043 Sngl Ply/2"Iso/2" Conc/Mtl Deck No No 0.14 4.74 71.00 7.2870 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 82 ASPHALT -SHINGLE AND SIDING 0.00 ❑ 2 11 2 in. Insulation 0.1670 0.00 ❑ 3 47 2 in. Heavyweight concrete 0.1670 0.00 ❑ 311/06 EnergyGauge F1aCom v 2.11 7 SIN RNW20913 RIGHT-NCOMMERCIAL / INDUSTRIAL LOAD CALCULATION 2/27/06 For: FIRST SOURCE COM4ERCE PARK (#A-103) Zone: 1 Job#: BLD A UNIT A-103 S KINGS HWY ST LUCIE City: Fort Pierce, FL, US By: ABBOTT & ASSOCIATES LWH: 482.0 x 1.0 x 9.0 Units: U.S. customary (I-P) 1. DESIGN CONDITIONS - COOLING ( 3 PM , August ) Dry Bib RH Moisture Outdoor Conditions ---> 90 59 bidoorConditions -> 75 50 TOD Convection - 0 Difference 15 61 Range Wet BIb 15 78 63 2. GLAZING SOLAR HEAT GAIN ( Lot = 27..00 ON, Copst Wt = L Type Du Shad Tilt O/oovr Area Sfact Shgf Shad GLAZ 1 E N 90 100.0 78 0.69 64 1.0 Page: 1 Mult = 1.0 ) - Sens 1668 3. TRANSMISSION GAINS Type D r GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ 1 E 78 78 1.040 15.0 N - 1217 WALL 1 N 24 24 0.122 D 12.5 N D 37 WALL 1 S 24 24 0.122 D 20.5 N D 60 WALL 1 E 72 72 0.122 D 33.5 N D 294 WALL 2 N 15 15 0.082 D 12.5 N D 15 WALL 2 S 15 15 0.082 D 20.5 N D 25 WALL 2 E 153 153 0.082 D 33.5 N D 420 PART 1 - 221 221 0.087 15.0 - D 288 ROOF 1 - 482 482 0.040 24.0 - D 463 4. INTERNAL BEAT GAIN Sens Latent People 4 x Per person: sensible 190 latent 230 760 920 0 x Per person: sensible 300 latent 300 0 0 Lights Incandescents in RA Ceiling 0 x 3.4 x 60% 0 Fluorescents in RA Ceiling 0 x 4.1 x 60% 0 Incandescents other 0 x 3.4 x 100% 0 Fluorescents other 600 x 4.1 x 100% 2460 Motors Nmbr Power Gain Load Fact Usage I 1 0.00 0 1.00 1.00 0 2 1 0.00 0 1.00 1.00 0 3 1 0.00 0 1.00 1.00 0 Appl. Nmbr Type Sens Latent Usage 1 1 ALL 2800 800 1.00 2800 800 2 1 0 0 1.00 0 0 3 1 0 0 1.00 0 0 4 1 0 0 1.00 0 0 5 1 0 0 1.00 0 0 Other 1 0 0 1.00 0 0 5. INFILTRATION Sens Latent 0 cfm > x db Temp Diff 15. 0 x 1.1 0 > x Moist. Diff 61.5 x 0.68 0 Manual N: 4th Edition Right-N: Ver.3.0.01 Certified by ACCA to meet all requirements of Manual Form N Job S: BLD A UNIT A-103 S KINGS HWY ST LUCIE Page: 2 6. SUBTOTAL COOLING LOAD FOR SPACE 10508 1720 7. SUPPLY DUCT HEAT GAIN Gain factor 0.10 ' x Line 6 Sensible Gain 1051 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawtbru Fan = 11559 (L S Sens. ) / ( 1.1 x Supply ID ) = cfm Est Cooling cfm = ( 11559) / (1.1 x 20.0 ) = 526 Actual Cooling Fan > = 526 9. I VENTILATION 80 cfm x db Temp Diff 15.0 x 1.1 1319 -> x Moist. Diff 61.5 x 0.68 3345 10. iRETURN AIR LOAD FROM LIGHTING AND ROOF Incandescent Lights 0 Watts x 3.4 x 40% 0 Fluorescent Lights 0 x 4.1 x 40% 0 RA Roof Load from Line 3 M 0 RA Ceiling Load Credit from Line 3 (-) 0 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT(Btah) 12878 5065 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB -Outside DB) _ ( 70 - 42) = 28 14. ,TRANSMISSION LOSSES [ Mult = 1.0 ] - Type Expos GrAtea NetArea Uval HTD Loss GLAZ 1 E 78 78 1.100 28.0 2402 WALL 1 N 24 24 0.122 28.0 82 WALL 1 S 24 24 0.122 28.0 82 WALL 1 E 72 72 0.122 28.0 246 WALL 2 N 15 15 0.082 28.0 34 WALL 2 S 15 15 0.082 28.0 34 WALL 2 E 153 153 0.082 28.0 351 PART 1 - 221 221 0.087 28.0 538 ROOF 1 - 462 482 0.040 15.0 289 15, 1NFt1 TRATION 0 cfm x db Temp Diff 28.0 x 1.1 Loss 0 16. SUBTOTAL HEATING LOAD FOR SPACE 4060 17. SUPPLY DUCT HEAT LOSS Loss factor 0.05 x Line 16 Loss 203 18. VENTILATION 80 cfm x dbTemp Diff 28.0 x 1.1 2462 Manual N: 4th Edition Right-N: Ver.3.0.01 Certified by ACCA to meet all requirements of Manual Fort N Job#: BLD A UNIT A-103 S KINGS HWY ST LUCIE Page: 3 19. HUMIDlnCATION Inside RH desired 32.0 (Max = 32.0 for I pane ) N of Glazing panes 1.0 (Max = 52. 0 for 2 pane ) 80 cfm x 1.48 g/100cfm/d = 1.2 gpd 434 20. iRETURN DUCT 13EAT LOSS Loss faeter 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 17159 Manual N: 4th Edition Right N: Ver.3.0.01 Certified by ACCA to meet all requirements of Manual Form N