Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance SCANNED Project Name: KRAFT BY St. Lucie l+V unty ProjectAddress: 13 CASTLE CT, FT PIERCE Permit #: Occupancy Type: Construction Type: IINSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. " Note: Form not required for interior renovations provided that no exterior structural elements are affected and ,certain minor building permits at the discretion of the local building official. Contact the # above for questions. 'DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 165 mph _ASD x LRFD End Zone Width: 1 ft .5. Mean Roof Height 4.5'*/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 16. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4:460.61.64.1 Zone 5: `70.11-74.5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, %kqe be�tof my knowledge and belief, the attached plans & specifications have been designed to comply w't�N � Ala tc _Suctural portions of the building codes currently adopted and enforced by St. Lucie N dr County` cet��elI elements depicted on these plans provide adequate resistance to the design force d-. d03(y� m DANIEL PAUL RETHERFORD 72451 _. Print Name Cert # & Co. Cart Auth. Signature, fl�f %f \�\\\ 1402 HARTMAN ROAD, FT PIERCE, FL 34947 )Ill% Company Name & Address Revised 07/25/2014