HomeMy WebLinkAboutPRODUCT APPROVALaC1S Home Log In I User Rellstritlon ',, Hotr�.trs�y [EVe to 6® ; Pudb'
aaa��� ;yP
'v{+ Product Approval
{ 0 =. Public 1.,
Protluct A orovai Menu > ProJuct or Aacl'wtian Search > QRplicabon tast> Appllratlon petail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Small
Category
Subcategory
Compliance Method
FL17443-R1
Revision
2017
Approved
J A TAYLOR ROOFING
302 Melton Drive
FT PIERCE, FL 34982
(772)466-4040
kylewhite2280aol.com
bliweoos FBC Staff BCIS Site Map Dnk I Search
y
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
Kyle Taylor T 0i ,^
kylewhite228@301.com rf2�� (i/i(
ST. LUCIE COUr
REVIEWED FOR
PLANS `AND A�RMIT MUST BE
SITE OR NO INSPECTION(S)'
Roofing
Metal Roofing
SCANNED
BY
St. Lucie County
MADE
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date
01/23/2023
Validated By
Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
FL17443 Rl COI FL 17443 J A Taylor 2017 Code Eval Report with Details
RSSS.pAf
Referenced Standard and Year (of Standard) Standard
Year
TAB 125
2003
UL 1897
2012
UL580
2006
Equivalence of Product Standards
Certified By
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
Sections from the code REQUIRED BY FIELD INSPECT ORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Fl # Model, Number or Name
17443.1 5 V Crimp
Method 1 Option D
01/24/2018.
02/14/2018
02/17/2018
04/10/2018
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant:. N/A
Design Pressure: +N/A/-129.25
Other: -129.25 @ 6" o.c. -69.25 @16" O.C. margin of safety
2;1 with: 24" max. coverage Install per manufacturers detail.
Not for use in HVHZ..
17443.2 1 VICTORIAN CRIMP SHINGLE
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-105
Other:-105PSF margin of safety 2:1. Install per
manufacturer's details and in compliance with FBC 2017 6th
ad. Not for use in HVHZ.
Description
1/2" rib height over 15/32" APA plywood
Installation Instructions
F1,17443 RI it FL 174431 AT r2017 Code Eval Renort
ri h Details RS55 pd1
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
Party: Yes
26GA 1/2" RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER
CDX/APA 15132" PLYWOOD
Installation .Instructions
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 RI AE FL 17443 ] A Taylor 2017 Code Eval Reodr
with Details RSSS pdf
Created by Independent Third Party: Yes
Contact U=_:: 2601 Blair hone Road Tallahassee R 32399 Phone: 850A874824
The state. of Honda Is an AA/EEO employer. S91Ydi9ht 2007 2013 State of Flodtla. e: PSIY9SY Statement ;: Accessihihty Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. `Pursuant to Section
455.275(1), Florida Statutes, enective October 1, 2012,licensees llmin ed under Chapter 455, Fs. must provide the Department with an email soil If they have
one. The emads provided may be used for offlcial communication with the licensee. However email addresses are public record. if you do not wish W supply a personal
address, please provide the Department with an all address which ran be made available to the public. To determine If you area licensee under Chapter 455; F.S.,
please dick here.
produce Approval Accepts;
M ® EE
Credit Card
safe
Fort Pierce, FL 34962
(7721466-4040
Compliant with Florida Building Code 2017 (61 ed.)
Compliant with Florida Product Approval Rule 9 61620-3
Compliant Quality Assurance Program: PRI CONSTRUCTION MATERIALS TECHNOLOGY
FBC Sections- 1504.3.2.1507
SV Crimp thru fastened W rib at each panel edge and 1 fastener In the center of the panel, 24" net coverage, 26GA ASTM
A794 6-50, AZSS, .018, SOksl min. over min.15/32" thick COX plywood deck: Corrosion Resistant fastener 119-15 HWH with
sealing washers, metal to wood connections with fastener length to penetrate 5/16" thru substrate. Fasten along the crown
of the rib in the center of panel and along the lap. First fastener to be within 3" of panel edges. Min. SDxr annular ring shank
nails spaced 6" D.C. reroofing, with less than 19/32" plywood (min.15/32"), this attachment Is to be used in addition to
existing attachment. Deck slope 2:12 or greater and shall: be compliant with FBC 2017 6TM ed. Underlayment: See'FBC 2017 67"
ed., Sec. 1507 Table' 1507.1.1
••Design Pressure:
Spacin
-69.25 PSF
16" O.C.
-129.25 PSF
6" D.C.
26GA ASTM A79Z, G-50, AZSS,..018, SOW Victorian Crimp Shingle over 1513Z" COX(APA Plywood attached to roof trusses.
Corrosion Resistant Fastener#10 x 1" Zinc plated, MTW Pancake Head, installed at 2 per panel into lock seam. Panels applied
with 12" exposure, adjacent shingles Inserted into lock seam of previous shingle. Deck slope 2:12 or greater and shall be
compliant with FBC2017 6t" ed. Underlayment:See FBC 2017 67'ed., Sec 1507 Table-1507.1.1
"Design Pressure:
-105 PSF
Reference Data:
TEST REPORTS
Hurricane Test Laboratory (TST-1527) 80224-0501-06 TAS 125 (UL580.942)
PRI Construction Materials Technologies (TST-5878) #FAE-023-02-01 UL 580-06/UL 1897-04r
1. UL 580-94 test standards are equivalent to UL 580.06 test standards.
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6'" ed.. see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2017 6`h ed., and per with.Manufacturer's installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-0
4. Engineering analysis for "project specific approval by local authorities wfjurisdictionis allowed by other registered
engineers.
S. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC2017 611 ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial Interest In any company manufacturi%TfIf fiQuting products
under this evaluation. ,tttt$Ow/ �rygrr
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or_�iA-tog llroiu uifder this
report.
5 V Crimp
Fastener- #9-15 corrosion resistant w/sealing washers
24" coverage
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2017 Florida Building Code, Section 1507
Perimeter fastening: 6"o.c.
Main Field fastening I 2"o.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel
VICTORIAN CRIMP
I
MINIMUM 2 FASTENERS
ATLOCKSEAM
� CUT 112 SHINGLE
1EATE STAGGERED
ERN
IRiAN CRIMP
3LES
9"EXPOSURE
w
Fastener#10x 1"
Zinc Plated MTW
Pancake Head