HomeMy WebLinkAboutCOMPACTION TESTENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8550 wire•.floridaengineeringandtesting.com 250 S.W.13"' Avenue Pompano Beach, FL 33069 PROCTOR COMPACTION TEST DATE SAMPLED: 1/16/2019 DATE TESTED: 1/21/2019 ORDER M 19-410 CLIENT: Craftmaster Custom Pools, Inc. ADDRESS: 8233-20 Gator Lane West Palm Beach, Florida 33411 PROJECT: Proposed Pool Deck Ciuperger Residence ADDRESS: 15370 Sky King Drive Port Saint Lucie, Florida MATERIAL DESCRIPTION: SAMPLED BY: P.N. Brown Slightly Silty Fine Sand Slight Trace Rock TESTED BY: P.T. SPECIFICATION GOVERNING: ASTM D-1557 Method C LAB NO: P-410 RESULTS OF TEST: The following compaction test was conducted in accordance with the Standard Methods of Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop as per the above specified method. MOISTURE % WET DENSITY (PCF) DRY DENSITY (PCF) 8.0 115.9 107.3 SCANNED 10.2 120.9 109.7 BY 12.5 123.6 109.9 St. County 14.6 122.4 106.8 Optimum Moisture (Percentage): 11.6 % 114 113 112 Maximum Dry Density (lbs./tuft.) 110.1 (PCF) a 111 (~ 110 wlIII)/////// w us 109 Respectfully Submitte\\l� , ALAN ,� //// ❑ 108 Mark A. Mesiano, 9.0. Florida EngineerirrT.9 �estinT�T ; Qr ` 106 10o 7 8 9 10 11 12 13 14 15 Florida Reg. No. 482�; N�� Certificate of Authoriz�4di6�j�IR/I1�16111O MOISTURE %As a mutual protection to clients, the publ��n8 68r�211`\\all reports are submitted as the confidential property of client , a t��yyii��ti��ppeett0 I' ion of statements, conclusions or extracts from or regarding our reports is reserved pending our Witten approval. 9 t Quality Q�Q A�♦r/Jlasrerance JAN 2 9 2019 Permitting Department r1 r • - ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8550 ww,w.floridaengineeringandtesting.com 250 S.W.13"' Avenue Pompano Beach, FL 33069 REPORT OF FIELD COMPACTION TESTS DATE: 1/16/19 ORDER NO: 19-410 PERMIT NO. CLIENT: Craftmaster Custom Pools, Inc. ADDRESS: 8233-20 Gator Lane West Palm Beach, Florida 33411 PROJECT: Proposed Pool Deck Ciuperger Residence ADDRESS: 15370 Sky King Drive Port Saint Lucie, Florida MATERIAL DESCRIPTION: Brown Slightly Silty Fine Sand Slight Trace Rock PROCTOR VALUE (PCF): 110.1 OPTIMUM MOISTURE (%): 11.6 % COMPACTION REQ'D BY SPECS: 95 LABORATORY NO: P-410 NUCLEAR GAUGE SERIAL #: ❑ 29793 (Model 3440) ® 533 (Model 3450) ❑ 20500 (Model 3440) PROCTOR METHOD: ® ASTM D-1557 ❑ ASTM-D698 ❑ AASHTO T-180 ❑ AASHTO T-99 ASTM D 6938 METHOD A Test # Location: Lift Elev./ Depth of Test Dry Density C Penetro- meter Readings Moisture %) Percent Compaction (%) Pass/ Fail 1 N. Side of Pool Final 6" 109.1 45 9.4 99.1 P 2 N. Side of Pool 1st 6" --- 45 --- >95* P 3 E. Side of Pool Final 6" 109.6 45 8.7 99.5 P 4 E. Side of Pool 1st 6" --- 45 --- >95* P 5 S. Side of Pool Final 6" 108.7 45 9.9 98.7 P 6 S, Side of Pool 1st 6" -- 45 --- >95* P 7 8 9 10 percentage estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. TESTED BY: P.N. CHECKED BY: P.T. Notes: Method A - Direct Transmission unless otherwise noted. PR - Pro Iof Roll BOF - Bottom of Footing TOB - Top of Base SG - Subgrade SOG - Slab on Grade As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. ,CC '�N, Quality 4 JAII� ✓lswerance