Loading...
HomeMy WebLinkAboutEVALUATION REPORTDIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 06 05 23—WOOD, PLASTIC, AND COMPOSITE FASTENINGS SCANNED BY St. Lucie County REPORT HOLDER: SIMPSON STRONG -TIE COMPANY INC. 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588 EVALUATION SUBJECT: SIMPSON STRONG -TIE® HURRICANE AND SEISMIC STRAPS AND TIES FOR WOOD FRAMING ICC ICC ICC CPIVIG c� Look for the trusted marks of Conformityl "2014 Recipient of Prestigious Western States Seismic Policy Council ��� (WSSPC) Award in Excellence" ASubsidiaryof wwOt""u10""t oRNA110 ie ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied as Go Jq EG to anyfinding or other matter in this report, or as to any product covered by the report. E` wc+auon a+ay ++ooa Copyright 0 2017 ICC Evaluation Service, LLC. All rights reserved. IMES EvaluationReportESR-2613 Reissued June 2017 Revised December 13, 2017 This report is subject to renewal June 2018. www.ice-es.org 1 (800) 423-6587 1 (562) 69941543 A Subsidiary of the International Code Council® DIVISION: 06 00 00—WOOD, PLASTICS, AND COMPOSITES Section: 06 05 23—Wood, Plastic, and Composite Fastenings REPORT HOLDER: SIMPSON STRONG -TIE COMPANY INC .5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588 (800)926-5099 www.strongtie.com EVALUATION SUBJECT: SIMPSON STRONG -TIE® HURRICANE AND SEISMIC STRAPS AND TIES FOR WOOD FRAMING 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2015, 2012, 2009 and 2006 International Building Code® (IBC) ■ 2015, 2012, 2009 and 2006 Intemational Residential Code® (IRC) Property evaluated: Structural 2.0 USES The Simpson Strong -Tie® hurricane and seismic straps and ties described in this report are used as wood framing connectors in accordance with Section 2304.10.3 of the 2015 IBC and Section 2304.9.3 of the 2012, 2009 and 2006 IBC. The products may also be used in structures regulated under the IRC when an engineered design is submitted in accordance with Section R301.1.3 of the IRC. 3.0 DESCRIPTION 3.1 General: The Simpson Strong -Tie hurricane and seismic straps and ties recognized in this report are installed .to resist design farces on wood -frame construction resulting from the application of the most critical effects of the load combinations prescribed by code that include wind or seismic loads. 3.1.1 Hurricane Ties: Hurricane ties are used to anchor wood rafters or joists to wood wall plates or studs or to anchor wood studs to wood sill plates. The H6 and H7Z ties are formed from No. 16 gage galvanized steel; the H1, H2.5A, H3, H5, H10A, and H10-2 ties are formed from No. 18 gage galvanized steel; and the H4 tie is formed from No. 20 gage galvanized steel. See Table 1 for tie model numbers, tie dimensions, fastener schedules, and allowable loads. See Figures la and 11b for Illustrations of the hurricane ties recognized in this report, and Figure 1c for illustrations of installation configurations with designated allowable load directions. 3.1.2 HS24 Hurricane Tie: The HS24 hurricane tie anchors wood rafters or trusses to wood wall top plates. The HS24 connector is formed from No. 18 gage galvanized steel. See Table 2 for required fasteners and allowable loads. See Figure 2 for a drawing of the HS24 tie and a typical installation detail. 3.1.3 LTS, MTS, and HTS Series Twist Straps: The LTS, MTS, and HTS series twist straps are used to anchor wood trusses or rafters to wood wall double top plates, wood studs, wood beams, or wood rim boards. The LTS, MTS, and HTS series twist straps are formed from No. 18, No. 16, and No. 14 gage galvanized steel, respectively. See Table 3 for strap model numbers, overall strap lengths, required fasteners, and allowable uplift loads when installed with different fastener schedules. See Figure 3 for a drawing of an LTS12 twist strap and two typical MTS strap installations. 3.1.4 LFTA Light Floor Tie Anchor: The LFTA light floor tie anchor is used as a floor -to -floor tension tie and is formed from No. 16 gage galvanized steel. See Table 4 for anchor tie dimensions, required fasteners, and the assigned allowable uplift load. See Figure 4 for a drawing of the LFTA connector. 3:1.5 SP and SPH Series Stud Plate Connectors: The SP1connector fastens one edge of a wood stud to the contiguous edge of a wood sill plate, and the SP2 connector fastens to one side of a wood double top plate and to the contiguous edge of a wood stud. The SP4, SP6, SPB, SPH4, SPH6, and SPH8 are 1'14-inch-wide (32 mm) U-shaped straps with a horizontal portion that bears against the wood wall top plates or sill plates and two vertical legs that are nailed to the edges of a wood stud. The SP and SPH connectors are fabricated from No. 20 and No. 18 gage galvanized steel, respectively. See Table 5 for SP and SPH models, connector dimensions, required fasteners, and allowable uplift loads. See Figure 5 for drawings of the SP1 and SP2 connector, and of typical stud -to -plate connection details for the SP1, SP2, SP4, and SPH4 connectors. 10C-ESEwhiation Reports an not to be corrsnuedas represmttngaestheHu or any other attributes not spechcarry addressed, nor are they robe construed as an endorsement of the subject afthe report or a recommendadonfor its are. There is no warramy byrCC Evaluation service, LLC, express ortmplied, as to aryfindingor other matter in this report, or as to any product covered by the report ®� , Copyright 6 2017 ICC Evaluation Service, I.I.C. All rights reserved. Page 1 of 11 ESR-2613 1 Most IMdelyAccepted and Trusted Page of 11 3.1.6 RSP4 Reversible Stud Plate Ties: The RSP4 tie plates are used to connect a nominally 211rch-wide wood stud to either a top or sill plate of a wood framed wall. The RSP4 tie connector is fabricated from No. 20 gage galvanized steel. See Table 6 for required fasteners and allowable loads. See Fiqure 6a for a drawing of the RSP4 connector showing overall dimensions; Figure 6b for a drawing of a typical RSP4 installation connecting a wood double top plate to a wood stud; and Figure 6c for a typical RSP4 installation connecting a wood stud toa wood sill plate. 3..1.7 SSP and DSP Stud Plate Connectors: The SSP stud -to -plate connector is used to provide a positive connection between a single wood stud and the top or sill plate of the same wood wall, and the DSP stud -to -plate connector is used to provide a positive connection between a double wood stud and the wood wall top or sill plate of the same wood wall. The SSP and DSP connectors are fabricated from No. 1S gage galvanized steel. See Table 7 for required fasteners and allowable uplift loads. See Fi ure 7 for drawings of the SSP and DSP connectors showing overall dimensions; a drawing of an SSP installation connecting a stud to a sill plate; and a drawing of a DSP installation connecting a double wood stud assembly to a top plate., 3.1.8 HGT Heavy Girder Tiedown Brackets: The HGT heavy girder tiedown brackets are used to provide a Positive connection between wood roof beams or multi -ply wood roof trusses and wood posts vertically aligned to support the end reaction of the beam or truss member. The HGT tiedown connector is a U-shaped bracket that is installed over the top chord of the roof truss having a slope from 3:12 (14 degrees) to 8:12 (34 degrees). Other components required for the connection, such as the anchor rods and hold-down or fie -down devices, that must be used to form a complete load path to resist design uplift forces from their point of origin to the load -resisting elements, that is, the vertically aligned supporting wood post, must be designed and specified by the registered design professional. The HGT tiedown brackets are fabricated from No. 7 gage steel, and are supplied with insert plates and crescent washers. See Table 8 for tiedown connector models, connector dimensions, fastener schedules, and allowable uplift loads. See Figure 8 for a drawing of the HGT-2 tiedown connector. 3.2 Materials: 3.2.1 Steel: Unless otherwise noted, the connectors described in this report are fabricated from ASTM A653, SS designation, Grade 33, galvanized steel with a minimum yield strength, Fy, of 33,000 psi (227 MPa) and a minimum tensile strength, Fu, of 45,000 psi (310 MPa). The HTS twist straps, the SSP and DSP stud -to -plate ties, and the H2.5A hurricane tie are fabricated from ASTM A653, SS designation, Grade 40, steel with a minimum yield strength• of 40.000 psi (275 MPa) and a minimum tensile strength of 55,000 psi (379 MPa). The body of the HGT heavy girder tiedown bracket is fabricated from ASTM A1011, SS designation, Grade 33, hot rolled steel with a minimum yield strength of 33,000 psi (227 MPa) and a minimum tensile strength of 52,000 psi (358 MPa), and the crescent washers of the HGT bracket are fabricated from ASTM A36 steel with a minimum yield strength of 36,000 psi (248 MPa) and a minimum tensile strength of 58,000 psi (399 MPa). Base -metal thicknesses for the connectors in this report are follows: NOMINAL THICKNESS (gage) MINIMUM BASE -METAL THICKNESS (inch) No. 3 0.2285 No. 7 0.1705 No. 10 0.1275 No. 14 0.0685 No. 16 0.0555 No. 18 0.0445 No. 20 0.0335 For SI: 1 Inch = 25.4 mm. The galvanized connectors have a minimum G90 zinc coating specification in accordance with ASTM A653. Some models (designated with a model number ending With Z) are available with a 0185 zinc coating specification in accordance with ASTM A653. Some models (designated with a model number ending with HDG) are available with a hot -dip galvanization, also known as "batch' galvanization, in accordance with ASTM A123, with a minimum specified coating weight of 2.0 ounces of zinc per square foot of surface area (600 g/m2), total for both sides. Model numbers in this report do not include the Z or HDG ending, but the information shown applies. The HGT Heavy Girder Tiedown Brackets have a painted finish and may also be available with the HDG finish. The lumber treater or holder of this report (Simpson Strong -Tie Company) should be contacted for recommendations on minimum corrosion resistance of steel connectors in contact with the specific proprietary preservative treated or fireretardant treated lumber. 3.2.2 Wood: Supporting wood members t0 which these connectors are fastened must be solid sawn lumber, glued - laminated lumber, or engineered lumber (such as Laminated Veneer Lumber (LVL), Parallel Strand Lumber (PSL), and Laminated Strand Lumber (LSQ1 having dimensions consistent with the connector dimensions shown in this report Unless otherwise noted, supporting wood members and supported members must have an assigned minimum specific gravity of 0.50 (minimum equivalent specific gravity of 0.50 for engineered lumber), except as noted in Table 5 for the SPH stud plate tie connectors, which provides values for which lumber members having assigned minimum specific gravities of 0.50 and 0.55 are required; and Table 7 for the SSP and DSP stud -to -plate tie connectors, which permits lumber having assigned minimum specific gravities of 0,50 and 0.43. The lumber used with the connectors described in this report must have a maximum moisture content of 19 percent (16 percent for engineered lumber) except as noted in Section 4.1. The thickness of the wood members must be equal to or greater than the length of -the fasteners specified in the tables in this report, except if noted otherwise in the tables and accompanying footnotes in this report, or as required by wood member design, whichever controls. 3.2.3 Fasteners: Bolts, at a minimum, must comply with ASTM A36 or A307. Nails used for connectors, straps, and lies described in this report must comply with ASTM F1667 and have the following minimum dimensions and bending yield strengths (Fyb): ESR-26131 Most Widely Accepted and Trusted Page 3 of 11 FASTENERS NAIL DIAMETER (inch) NAIL LENGTH (inches) F +' (psi) 8d x 1% - 0.131 1% 100,000 8d 0.131 2% 100,000 10d x 1% 0.148 ill, 90,000 10d 0.148 3 90,000 For SI: 1 inch = 25.4 mm. Fasteners used in contact with preservative treated or fire retardant treated lumber must comply with Section 2304.10.5 of the 2015 IBC, Section 2304.9.5 of the 2012, 2009 and 2006 IBC, Section R317.3 of the 2015, 2012 and 2009 IRC or Section R319.3 of the 2006. IRC, as applicable. The lumber treater or this report holder (Simpson Strong -Tie Company) should be contacted for recommendations on minimum corrosion resistance of fasteners and connection capacities of fasteners used with the specific proprietary preservative treated or fire retardant treated lumber. 4.0 DESIGN AND INSTALLATION 4.1 'Design: The tabulated allowable loads shown in this report are based on allowable stress design (ASD) and include the load duration factor, Co, corresponding with the applicable loads in accordance with the National Design Specification® for Wood Construction (NDS). Tabulated allowable loads apply to products connected to wood used under dry conditions and where sustained temperatures are 100°F (37.8°C) or less. When products are installed to wood having a moisture content greater than 19 percent (16 percent for engineered wood products), or when wet service is expected, the allowable loads must be adjusted by the wet service factor, CM, specified in the NDS. When connectors are installed in wood that will experience sustained exposure to temperatures exceeding 100°F (37.8°C), the allowable loads in this report must be adjusted by the temperature factor, Ct, specified in the NDS. Connected wood members must be analyzed for load - carrying capacity at the connection in accordance with the NDS. 4.2 Installation: Installation of the connectors must be in accordance with this evaluation report and the manufacturer's published installation instructions. In the event of a conflict between this report and the manufacturer's published installation instructions, this report governs. 4.3 Special inspection: 4.3.1 Main Wind -force -resisting Systems under the IBC: Periodic special inspection must be conducted for components within the main wind -force -resisting system, where required in accordance with Sections 17042 and 1705.11 of the 2015 IBC, Sections 1704.2 and 1705.10 of the 2012 IBC, Sections 1704 and 1706 of the 2009 IBC, and Section 1704 of the 2006 IBC. 4.3.2 Seismic -force -resisting Systemsunder the IBC: Periodic special inspection must be conducted for components within the seismic -force -resisting system, in accordance with Sections 1704.2 and 1704.12 of the 2015 IBC, Sections 1704.2 and 1705.11 of the 2012 IBC, and Sections 1704 and 1707 of the 2009 and 2006 IBC. 4.3.3 Installations under the IRC: Special inspections are normally not required for connectors used in structures regulated under the IRC. However, for components and systems requiring an engineered design in accordance with IRC Section R301, periodic special inspection must be in accordance with Sections 4.3.1 and 4.3.2 of this report. 5.0 CONDITIONS OF USE The Simpson Strong -Tie Hurricane and Seismic Straps and Ties described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The connectors must be manufactured, identified and installed in accordance with this report and the manufacturer's published installation Instructions. A copy of the .instructions must be available at the jobsite at all times during installation. 6.2 Calculations showing compliance with this report must be submitted to the code official. The calculations must be prepared by a registered design professional where required by the statues of the jurisdiction in which the project is to be constructed. 5.3 Adjustment factors noted in Section 4.1 and the applicable codes must be considered, where applicable. 5.4 Connected wood members and fasteners must comply, respectively, with Sections 3.2.2 and 3.2.3 of this report. 5.5 Use of connectors with preservative or fire retardant treated lumber must be in accordance with Section 3.2.1 of this report. Use of fasteners with preservative or fire retardant treated lumber must be in accordance with Section 3.2.3 of this report 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Joist Hangers and Similar Devices (AC13), dated February 2017. 7.0 IDENTIFICATION The products described in this report are identified with a die -stamped label or adhesive label indicating the name of the manufacturer (Simpson Strong -Tie), the model number, and the number of an index evaluation report (ESR-2523) that is used as an identifier for the products recognized in this report. ESR-2613 l Most Widety Accepted and Trusted Page 4 of 11 TABLE 1—HURRICANE TIES MODEL FASTENERS (Quantity -Type) ALLOWABLE LOADS' _ (Ibs) N0. To Rafter To Plates To Stud Connection Cdrifgurations' U Iiftas Co=1.6 Lateral&' Co=1.6 F Fa H1 6-8d x 1% 4-8d — 1 545 510 190 H10A 9-10d x I% 9-10d x l'/n — 1,040 565 285 H10-2 6-10d 6-10d — 655 430 355 H2.5A 5-8d 5-8d — 2 565 110 110 H3 4-8d 4-8d — 435 1 210 170 H5 4-8d 4-8d 440 100 225 H4 4-8d 4-8d 3 330 — — 4-8d 4-8d — 4 330 140 175 H6 — 8-8d 8-8d 5 1,230 — — H7Z 4-8d 2--8d 8-8d 6 830 410 — For SI: 1 Inch = 25.4mm, 1 Ibs = 4.45 N. 'Allowable loads are for one anchor installed to a minimum nominal 2x supported and minimum nominal 2x supporting wood member. A rafter minimum actual thickness of 2'/2 inches must be used when framing anchors are installed on each side of the rafter and on the same side of the plate. Allowable simultaneous loads in more than one direction on a single connector must be evaluated as follows: Design Uplift / Allowable Uplift + Design Lateral Parallel to Plate / Allowable Lateral Parallel to Plate + Design Lateral Perpendicular to Plate /Allowable Lateral Perpendicular to Plates 1.0. The three terms in the unity equation consider all possible forces that the hurricane tie may be designed. and installed to resist. The number of terms that must be considered for simultaneous loading is determined by the registered design professional and is dependent on the method of calculating wind forces and the assumed load path that the connector is designed to resist. '"Connection Configurations" shown in Figure 1c (next page) Indicale,the load directions F, and F2, and are detail''showing connector installations on the outside of the wall for clarity. Installation on the inside of the wall is acceptable to achieve the tabulated allowable loads. Connections in the same area (i.e. truss to plate connector and plate to stud connector) must be on installed on the same side of the wall to achieve the tabulated allowable uplift loads and ensure a continuous load path. 'Allowable uplift loads have been increased for wind or earthquake loading, and no further increase is allowed. Allowable loads must be reduced when other load durations govern. 6Aloowable lateral loads in the F, direction must not be used to replace diaphragm boundary members or nailing or replace solid blocking required by.code to laterally support the ends of joists/rafters. 'Additional shear transfer elements must be considered the connectorinstallation induces cross grain bending or tension of the truss or rafter members. 7l4^ y 11t r •ihc 6 / I 6 • am o • dam 6 • wmT 1' 1 6 • b • ib 6' ' I yo �a �• o Ila�l6 6 6 0 � 6144' • 1�a H1 F12.5A H3 FIGURE 1a-1-17, H2.5A, AND H3 HURRICANETIES ESR-2613 ) Most Widely Accepted and Trusted Page 5 of 11 H7Z FIGURE t b—H4, H5, H6, H7Z, H10A AND H10-2 HURRICANE TIES ❑1 H1 Installation ❑2 (H10A and HI 0-2 similar) H6 Stud It Band Joist Installatio H6 Stud to Double Tel Plate Installation H2.5A Installation (Nails into both top plates) (H3 and HS similar) o H4 Installation • / (Nails into upper top plate) H7Z Installation FIGURE 1e—CONNECTION CONFIGURATIONS OF HURRICANE TIE INSTALLATIONS SPECIFIED IN TABLE 1 ESR-2613 I Most Widely Accepted and Trusted Page 6 of 11 TABLE 2—HS24 HURRICANE TIE FASTENERS' (4uantity-Type) - ALLOWABLE LOADS (Ibs) Cb-1.6 MODEL+ NO. To Rafter or Truss To Double Top Plate Uplift Laterai3�s .. 6_ Fs HS24 8-8d x 1'/z & 2-Bd (slant) _ 8-8d 605 645 1.100 8-8dx 1% 8-8d 625 625 680 ui Si; i IrlCrl = 25.4 mm,, I iDs = 4.0 N. "Slant" nailing refers to 8d common nails Installed as toenails on each side of the connector. The nails must be driven through the connector at an angle approbmately 30' with the rafter/truss member with the nail penetrating through the rafter/truss member into the wood double top 3plate. The uplift loads have been increased for wind or earthquake loading. No further Increase is allowed. Allowable loads must be reduced when other load durations govern, 3Aloowable lateral loads in the Fr direction must not be used to replace diaphragm boundary members or nailing or replace solid blocking required by code to laterally support the ends ofjoists/rafters. 4Additionai shear transfer elements must be considered the connector installation induces cross grain bending or tension of the truss or rafter member. 'Fr load direction is parallel to plate, and Fi load direction is perpendicular to plate. 141," • • ' �� • HS24 Dimensions 3 . 20• U.S. Patents �e+ . 5,603,580 HS24 Installation and Allowable Load Directions FIGURE 2—HS24 HURRICANE TIE ESR-2613 I Most Widely Accepted and Trusted I Page 7 of 11 TABLE 3—LTS, MTS, AND HTS TWIST STRAPS TWIST STRAP SERIES MODEL NO' STRAP LENGTH (in) TOTAL QUANTITY OF FASTENERS' ALLOWABLE UPLIFT LOAD92P (Ibs) When Installed with 10d Common Nails When Installed with 10dxl'/i Common Nails When Installddl with 10d Common Nails When Installed with 10dxl'/z Common Nails Co =1.6 Co=1.6 LTS4 LTS12 12 12 12 660 600 LTS16 16 LTS18 18 LTS20 20 MTS1 MTS12 12 14 14 990 990 MTS16 16 MTS18 18 MTS20 20. MTS30 30 HTS16 16 16 16 1.310 1,310 HTS° HTS20 20 20 24 1,310 , 1,310 HTS24 24 HTS28 28 HTS30 30 HTS30C 30 'Half of the fasteners must be installed on each end of the strap to achieve the allowable uplift load. 2Tabulated allowable uplift loads must be selected based on duration of load as permitted by the applicable building code. 'Tabulated allowable uplift loads have been Increased for wind or earthquake loading. No further Increase is allowed. Allowable loads must be reduced when other load durations govem. °Each model of the LTS andMTS twist strap series (except for the MTS30) has more nail holes than the minimum quantity of nails specified in the table. 'HTS30C has the twist in the center of the strap length. I' Typ. LTS12 (MTS and HTS Similar) Typical MTS Installation — Rafter to Stud FIGURE 3—TWIST STRAPS Typical MTS Installation — Truss to Double Top Plate ESR-2613 I Most Widely Accepted and Trusted Page 8 of 11 TABLE 4—LFTA LIGHT FLOOR TIE ANCHOR' MODEL NO. LFTA ANCHOR DIMENSIONS.(in) 'FASTENERS° (Quantity —Type) - ALLOWABLE TENSION LOAD'' (Ibs) Co =1.6 Strap Width (W) Clear Span OJerell Length (L) LFTA 1 2'/a 17 383le 16-10d Common 1,325 For Si: t inch = 25.4 MM. 1 Ibs = 4.45 N. 'The LFTA anchor Is used to transfer tension forces between vertically aligned wood studs across floor framing with floor joists having a maximum nominal depth of 12 inches. Half of the fasteners must be installed on each end of the strap to achieve the allowable uplift load. 'Tabulated allowable uplift loads must be selected based on duration of load as permitted by the applicable building code. `Tabulated allowable uplift loads have been increased for wind or earthquake loading. No further Increase is allowed. Allowable loads must be reduced when other load durations govern. FIGURE 4—LFTA LIGHT FLOOR TIE ANCHOR ESR-2613 ( Most Widely Accepted and Trusted Page 9 of 11 TABLE 5—SP AND SPH STUD PLATE TES CONNECTOR SERIES MODEL N0.On=1.6 CONNECTOR DIMENSIONS (In) FASTENERS' (Quantity -Type) _ ALLOWABLE UPLIFTLOADSZ^-' (W) (L) To Stud To Plate ' S.G.=0.50 S.G.=0.55 SP1 — — 6-10d 4-10d 555 - 555 SP2 — — 6-10d 6-10d 1,010 1,010 SP SP4 3sl1s 7'/a 6-10d x 1'/z — 825 825 6-16d x 2% — 850 850 SP6 59/1e 7'/a 6-10d X 1'! z — 825 825 6-16d x 2% — 850 850 SP6 s 7 /, s 8116 6-10d x 1% — 825 825 6-16d x 2% — 850 850 - SPH4 39/ 8 Sa/a 10-10d x 1 % — — 1,040 ' 12. 10d X,1% — 1,286 1,175 SPH 'SPH6 59/16 9'/a 10-10d x 1'/ z — — 1,040 12-10dx1lz — - '1,280 1,415 SPH8 / 7°1e 811, 1D-10dx 11!2 — — '1;175 - 12-10d x 1% — .1;280: vi Sim i 4161= 25.4 mm, .I IDS = 4.40 N. 'For Models SP1 and SP2, one 10d common stud nail must be installed as a toenail. It must be driven through the connector at an angle approximately 30- with the stud with the nail penetrating through the stud into the wood sill plate. (See detail on this page entitled °SPI Nailing Profile.") 2Tabulated allowable uplift loads must be selected based on duration of load as permitted by the applicable building code. 'Tabulated. allowable uplift loads have been increased for wind or earthquake loading. No further increase is allowed. Allowable loads must be reduced when other load durations govern. 'Allowable uplift loads are given for wood assemblies consisting of lumber having an assigned specific gravity (S.G.) of 0.50, such as Douglas fir —larch, and 0.55, such as southern pine. �29 SNd DW L SPI/SP2 Typical SPH4 Installation: Stud to Wood Sill Plate (SP4 Similar) SP2 Installation: SP1 Nailing Profile Stud to Double Top Plate SPI Installation: Stud to Sill Plate Typical SP4 Installation: Double Top Plate to Stud.(SPH Similar) FIGURE 6—SP AND SPH STUD PLATE TIES ESR-2613 I Most Widely Accepted and Trusted Page 10 of 11 TABLE 6—RSP4 REVERSIRI E srl in DI ere rnuu=r,•n=+ ' MODEL FASTENERS (Quantity -Type) _ ALLOWABLE LOADS;z,(Ibs) C,=1.8 .. .. NO. To Stud To Plate Connection Cohfguration° Uplift I-,ateral° F, Fz RSP4 For Sl:l i,,,h = 97 4-8d x I% 4-8d x 1112 1;,-. Stud to Double Top Plate 390 165 245 Stud to Sill Plate 245 165 1 225 'Refer to Figure 6a for overall dimensions of the RSP4 plate connector. Tabulated allowable loads must be selected based on duration of load as permitted by the applicable building code. 'Tabulated allowable loads have been increased for wind or earthquake loading. No further increase.ls allowed. Allowable loads must be reduced when other load durations govern. 4Refer to Figure 6b and 6c for connection configurations. F, load direction is parallel to plate, and Fz load direction is perpendicular to plate. lsw I I , a 0 e 0 FIGURE 6a—RSP4 STUD PLATE CONNECTOR DIMENSIONS FIGURE 6b—RSP4 INSTALLATION: STUD TO DOUBLE TOP PLATE TABLE 7--SSP 4Nn nBD en in or e, ,c FIGURE 6c—RSP4 INSTALLATION: STUD TO SILL PLATE U.S. PATENT 5,697,725 FASTENERS ALLOWABLE UPLIFT LOADS' A (Ibs) MODEL (Quantity=Type) CD=1.6 NO. Studs Double Top Plate Sill Plate Double Top Plate SIII Plate S.G.= 0.50 S.G. = 0.60 S.G.= 0.43 4-10d x 11/z 3-1 Old x 1% — 330 — — SSP — 1-10d x I% — 395 310 4-10d 3-10d — 410 — - - 1-10d — 430 400 8-10d x 1'/z 6-10d x 1 % — 730 — — DSP — 2-1 Old x 1'/z - ... 620 515 8-10d 6-1 Old ._... — 2-10d — 780 565 Fnr RI.1I nF-ocw ...._.. r ... ,va 'Tabulated allowable uplift loads have been increased for wind or earthquake loading no further increase allowed. Reduce loads when other load durations govern. zWhen cross -grain bending or cross -grain tension cannot be avoided, mechanical reinforcement to resist such forces should be considered. 'For Sill Plate allowable uplift loads, all round nail holes in the connector must be filled with the specified quantity and type of nails. `For Double Top Plate allowable uplift loads, all round and triangular nail holes the tie connectors must be filled with the specified quantity and type of nails. 1'41 J1W1 8'• I 6"4e• � 61 • I I . • SSP DSP U.S. Patent U.S. Patent 7,065,932 7,065,932 7,368,973 7,356,973 SSP Installation: Single Stud to Sill Plate FIGURE 7—SSPIDSP STUD PLATE TIES DSP Installation: Double Stud to Double Top Plate ESR-2613 I Most Widely Accepted and Trusted Page 11 of 11 TABLE 8—HGT HEAVY GIRDER TIEDOWN CONNECTORS+•' ,..,. MODEL°ATHREAOED "N0. `yp::. HGT CONN,ECT,OR pISTANCE EETWEEN'. RODS' ' •-(iriclt`es) " ' " FASTENERS - , {QUantlty-Type)',,' ` 'ALLOWABL'EUPLIFT .. LOApssa'•-, :: �-�- (Ibs);. . ThreadeilRod • �ToMuttiptyTruss HGT-2 3e/1e 51/4 2A" Dia. 16-10d 10,345 HGT3-. :., .4+'6s', ;... . `T'/e . ',.?-s/a"DIa.", ;� _ .-.- 1(10d` i 104'4'0. .. .. .. ... HGT-4 Ols 9 2-s/e" Dia. 16-10d 11.395 For SI: 1 inch = 25.4mm,1 Ibs = 4.45 N. 'The HGT connector can accommodate top chord slopes from minimum 3:12 (14°) to maximum 8:12 (34°) and are provided with crescent washers for sloped top chord installations. 'All elements of the tie -down assembly (multi -ply trusses; vertically aligned wood studs/posts, and the full -height threaded rods) must be designed to resist applied loads. 'The HGT-2, HGT-3, and HGT-4 connector attaches to the heel joint of a two-ply, three-ply, and four -ply wood truss, respectively, where each Wen thickness Is nominal 2 inches. 'When the HGT-3 is used with a two-ply truss, shimming is required, and the shimming material must be similar (thickness and grade of lumber) as the truss member material. Additionally, the entire assembly must be designed by a registered design professional to act as one unit. 'Tabulated allowable loads must be selected based on duration of load as permitted by the applicable building code. 'The uplift loads have been increased for wind or earthquake loading with no further Increase Is allowed. Reduce loads when other load durations govern. 'Full -height threaded rods are shown in Figure 8 for illustration purposes only, as one method of transferring the design load from the HGT connector to the foundation. The threaded rod material specifications must be specified by the registered design professional. 'Two LBP 'fa -Inch washers must, be Installed on top of each crescent washer. LBP washers and crescent washers are required. Crescent washers are supplied with the connector. LBP'!e washers are available from Simpson Strong -Tie Company, and are .2-inch square by thick galvanized steel washers with a center bolt hole to accommodate a'/cinch diameter threaded bolt/rod. HGT-2 (HGT-3 and HGT-4 similar) Install two LBPW washers on top of each crescent washer (total four %washers) for wood installation. All washers and crescent washers are required. Crescerdwashers are supplied. Typical HGT-3 Installation with full height threaded rod. The design of the threaded rod, Including any necessary hardware or shrinkage compensating devices, is outside the scope of this report FIGURE 8—HGT HEAVY GIRDER TIEDOWN CONNECTOR