Loading...
HomeMy WebLinkAboutUNIFORM PERMIT APPLICATIONROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH -VELOCITY HURRICANE ZONES - UNIFORM PERMIT APPLICATION Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE SCANNED BY St. Lucie County COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 rescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaaltic5StiIng as'S' Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: I. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING 5.31 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Master Permit Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Process No. Contractor's Name I U -4 s k e. d 11-n �-• Job Addresscz�—lg(/''t�(%�i'"i�., ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOFTYPE V.New Roof 0 Repair CI Maintenance 0 Reroofing IS Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) - Steep Sloped Roof Area (SF) L4 i� Total (SF) Section B (Roof PIS Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 15.32 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slone Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 or Calculations: Pmax1: Pmax2: PmaX3: Max. Design Pressure, from the specific Product Approval system: Deck: Gauge/Thickness: Anchor/Base Sheet & No. of Ply(s): AnchorlBase Sheet Fastener/Bonding Material: Insulation Base Layer. Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s) & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Field: _" oc @ Lap, # Rows _ @ _" oc Perimeter: _" oc @ Lap, # Rows _ @ _" oc Corner: _" oc @ Lap, # Rows _ @ oc Number of Fasteners Per Insulation Board: Field_ Perimeter_ Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING 15.33 ROOF ASSEMBLIES AND'ROOFTOP STRUCTURES Florida Building Code Edition 6th Edition (2017) High -Velocity Hurricane zone Uniform Permit APPlication Form. Section D (Steep Sloped Roof System) Roof System Manufacturer: NZ I A Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations 11: 33 P2: P3: 04 Steep Sloped Roof System Description Deck Type: Type Underlayment: Rop� Slope: 5 � '� Q � � 3d (h , 5�_. 12 Insulation: N 5i,ecl. Fire Barrier: N r A S"hed Ridge Ventila'o '.2 Fastener Type & Spacing: i l�! I4- r'i Shank Adhesive Type:ET /I GG-E �..c?i'll2 ri'f Mean Roof Height: Type Cap Sheet: N hh e Roof Covering: . \ Type & Size Drip n Edge: \ 9aldanized a"xa" drib edges 15.34 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based dle systems, choose either Method.I or 2. Compare the values for Mr with the values from Mp If the Mt values are greater than or equal to the Mr values, for each area of the roof, then the dle attachment method is acceptable. Method I `Moment Based Tile Calculations Per RAS 127" (Pt:-xL-=-)-Mg;-=Met- Product Approval Mf_ (72.-x2.- )-Mg:_=Mr2- Product Approval Mf_ (P3:-x).- )-Mg:_=Mr3_ Product Approval Mf- Method 2 "Simpli6ed Tde Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Pn A.- a""..,...i ar. Mr required Moment Resistance` Mean Roof Height -> Roof Slope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 36.1 \37.3 5:12 28A 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based file systems endorsed by the Browsed County Board of Rules and Appeals: For Uplift based did systems use Method3. Compared the values for with the values for Fr. IftheF values ere greaterthan or equal ro the Fr values, for each area of the roof, than the the auachmenr method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS 127- (PI: x L_=_xw:=_)-W;_x cas8 _=Fr1_ Product Approval F_ (P2:x L_ =Xw:=_�-W;_x Cos h-_=Fr2_ Product Approval F_ (Pv: XL_ xwc= 1-w. ..... Whereto Obtain Information Description Symbol Where to find Design Pressure PI or P2 or P3 PAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H lob Site Roof Slope B fob Site Aerodynamic Multiplier d Product Approval Restoring Moment duem 01.1y Mg Product Approval Attachment Resistance Mf Product Approval Required Momeni Resistance M, Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W = width Product Approval AR calculations must be submitted to the building official at the rime of permit appBcadon. FLORIDA BUILDING CODE 6th Edition (2017) - BUILDING 15.35 SECTION 1524 -HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates -that the item has been explained. 1. Aesthetics -Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renafling Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code, Building. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The provides the option of maintaining this appearance. 5. Pending Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pending can be an indication of structural distress and may require the review of a professional structural engineer. Pending may shorten the life expectancy and performance of the new roofing system. Pending conditions may not be evident until the original roofing system is removed. Pending conditions should be corrected. 6. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a buildup of water. Perimeter/edge walls or other roof extensions may block this discharge If overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Chapter 16 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. COMMENTS: Owner's/Agent's ignature D to ontractk-nature City of Plantation Rev. 03/15/12 Owner's/Agent's ignature D to ontractk-nature City of Plantation Rev. 03/15/12 UL. Evaluation Report UL ER2453-02 Issued: April 5, 2017 Visit We On -Line certifications Dlreetorr. Www.ul.com/erdirectorV for current status of Report UL Category Code: ULEZ CSI MasterFormatal DIVISION: 07 00 00 —THERMAL AND MOISTURE Sublevel 2: 07 30 00 — Steep Slope Rooting Sublevel 3: 07 3100 — Shingles and Shakes Sub4avel 4: 07 3113 — Asphalt Shingles COMPANY: OWENS CORNING. ONE OWENS CORNING PKY TOLEDO, OH 43659 (419)248-7060 h�.ilww�.6wenscoenlatt.eom/ 1. SUBJECT: Asphalt Shingles CLASSIC®, SUPREME®, DURATION® PREMIUM, TRUDEFINITIONS DURATION®, TRUDEFINITIONO DURATION® STORMw TRUDEFINITIONS DURATION® MAXm, TRUDEFINITION® OAKRIDGM, OAKRIDGES, WOODCRESTS, WOODMOORS, TRUDEFINITIONS WEATHERGUARDS HP, BERKSHIREQ, DEVONSHIREw, WOODSTARTS STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI BUILT STARTER STRIP BERKSHIRE@ HIP & RIDGE SHINGLES, HIGH RIDGE HIP & RIDGE SHINGLES WITH SEALANT, RIZERIDGES HIP & RIDGE SHINGLES WITH SEALANT, WEATHERGUARDS HP HIP & RIDGE SHINGLES, PROEDGEA DURARIDGEn" HIP & RIDGE SHINGLES AND PROEDGES STORMS HIP & RIDGE SHINGLES 2. SCOPE OF EVALUATION 02015, 2012,'2009, and 2006 Intemational Bulding Code S (IBC) s2015, 2012, 2009, and 2006 Intsmatlonal Res/dential Code (D QRC) ■ [CC ES Acceptance Criteria for Quality Documentation (AC10), Dated December 2012 ® [CC ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012 The products were evaluated for the following properties: ■ External Fire Exposure (ANSI/UL790, ASTM El08) ■ Wind Resistance (ASTM D3161; ASTM D7158) ® Physical Properties ( iCC-ES AC438) 3. REFERENCED DOCUMENTS ® ANSIIUL790 Eighth Edition, (ASTM E108), Standard Test Methods for Fire Tests, of Roof Coverings ■ ASTM D3161-13, Standard Test Method for Wind -Resistance of Steep Slope Roofing Products (Fan -Induced Method) ■ ASTM D7158-11, Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method) ■ UL Subject 2375, Outline of Investigation for Hip and Ridge Shingles (UL Fire and Wind Tests) s ICC-ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012 4. USES OWENS CORNING asphalt shingles described in this report are alternatives. to asphalt shingles complying with Section 1507.2.5 of the 2015, 2012. 2009 and 2006 ISC and Section R905.2.4 of the 2015, 2012, 2009, and 2006 IRC, and are Class A roof coverings for new and existing roofs. S. PRODUCT DESCRIPTION OWENS CORNING asphalt shingles are roof covering materials complying with the following properties when installed as described in this report. The products are three -tab shingles, laminated shingles and hip & ridge shingles. The products are available in standard and metric sizes. Fire Classification: OWENS CORNING asphalt shingles covered under this Report have been tested for fire classification Class A in accordance with UL790 (ASTM E108). Shingles tested In accordance with UL790 (ASTM E108) qualify for use under Section 1505.1 of the 2015, 201E, 2009 and 2006 IBC and Section R902.1 of the 2015, 2012, 2009 and 2006 IRC. Wind Resistance: OWENS CORNING asphalt shingles covered under this Report have been tested for wind resistance in accordance with ASTM D3161 or ASTM D7158. Shingles tested in accordance with ASTM D3161 are classified as Class F or Class A and qualify for use under the exception to Section 1507.2.8.1 of the 2015 IBC, Section 15072.7.1 of the 2012, 2009 and 20D6 IBC, or the exception to Section R905.2.4.1 of the 2015, 2012, 2009 and 2006 IRC. Shingles tested in accordance with ASTM D7158 are classified as Class. H and qualify for use in locations as shown in Table 1504.1.1 of the 2015 IBC, Table 1507.2.7.1 of the 2012 and 2009 IBC or Table R905.2.4.1 of the 2015, 2012 and 2009 iRC, where the maximum basic wind speed is 150 mph (67 m/s) or less with exposure category of B or C (ASCE 7) and a maximum building height of 60 feet (18.3 m). Installation must be in accordance with Section 1507.2.7 of the 2015, 2012, 2009 and 2006 IBC or Section R905.2.6 of the 2015, 2012, 2009 and 2006 IRC, as applicable. Physical Properties: OWENS CORNING asphalt shingles covered under this Report have been tested for physical properties in accordance with AC 438. Shingles tested In accordance with AC438 qualify as an alternative roof covering for use under Section 1507.2.5 of the 2015, 2012, 2009 and 2006 IBC or Section R905.2.4 of the 2015, 2012. 2009 and 2006 IRC. When installed in new construction in accordance with this report and the OWENS CORNING installation instructions, the shingles are a Class A fire classification roof covering. When the shingles are installed over existing roof coverings, the fire classification is maintained. Page 2 of 30 MIAMI-DADS COUNTY Ml .'' Q REGULATORY AND ECONOMIC RESOURCES (RER) PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 llE %MINISTRATION DIVISION Marat Florida 331752474 T (786) 315 2590 F (786) 315.2599 NOTICE OF ACCEPTANCE (NOA) RM �MMff /kCGHGMV Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OR 43659 SCOPE: This NOA is being issued under the applicable rules, and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke; modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Oakridge®, TruDefrnition Oakridge@, and TruDefinition Oakridge® Artisan Colors Shingles LABELING: Each unit shall bear a permanent label with the manufacturer s name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEKENT: The NOA number preceded by the words Miami -Dade County, Florida,'and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 12-0430.01 and consists of pages 1 through 4. The submitted documentation was reviewed by Gaspar J Rodriguez. APPROVED 11 NOA No.: 15-1102.03 Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 1 of 4 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves a roofing system using Oakridge®, TruDefrnition Onkridge®, and TruDefinition Oakridge® Artisan Colors asphalt shingles manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Oakridgeg, 13 %4" x 39 3/s" TruDefmition Oakridge@, and TAS 110 A heavy weight, fiberglass reinforced laminate TruDetinition Oakridge® asphalt shingle with continuous bead of Artisan Colors sealant. Manufacturing Locations #1, 2, 3, 4 Oakridge®, 13 '/4" x 39 3/s" TruDefinition Oakridge®, and TAS 110 A heavyweight, fiberglass reinforced laminate TruDefinition Oakridge® asphalt shingle with dashed bead of sealant. Artisan Colors Manufacturing Location #1, 2, 3, 4, 5 MANUFACTURING LOCATION 1. Memphis, TN 2. Irving, TX 3. Savannah, GA 4. Jacksonville, FL S. Atlanta, GA EVIDENCE SUBMITTED TestAgencv TestIdentitier TestName/Reyort Date PRI Construction OCF-153-02-01 TAS 100 Materials Technologies OCF-152-02-01 TAS 100 09/22/10 OCF-158-02-01 TAS 100 09/21/10/10 OCF-151-02-01 /10 TAS 100 1111/10/10 OCF-150-02-01 TAS 100 OCF-165-02-01 09/21/10 TAS 100 OCF-170-02-01 Ol/07/11 TAS 100 OCF-177-02-01 06/06/11 TAS 100 OCF-178-02-01 12/05/11 TAS 100 02/02/12 M�AMWXDECOUMY NOA No.: 15-1102.03 Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 2 of 4 Underwriters 09NK14530 ASTM D 3462 12/31/09 Laboratories R2453 ASTM D 3462 10/11/10 R2453 ASTM D 3462 11/03/10 R2453 ASTM D 3462 10/11/10 R2453 ASTM D 3462 10/11/10 R2453 ASTM E 108 01/13/11 R2453 ASTM E 108 10/11/10 R2453 ASTME 108 11/03/10 R2453 ASTME 108 10/I1/10 R2453 ASTM E 108 10/11/10 09NK14530 TAS 107 (ASTM D 3161) 12/31/09 R2453 TAS 107 (ASTM D 3161) 10/27/15 IONK13947 TAS 107 (ASTM D 3161) 11/12/10 R2453 TAS 107 (ASTM'D 3161) 10/11/10 R2453 TAS 107 (ASTM D 3161) 10/27/15 1ONK13947 TAS 107 (ASTM D 3161) 01/28/11 I ICA15662 TAS 107 (ASTM D 3161) 05/27/11 I ICA65092 ASTM D 3462 / TAS 107 (ASTM D 3161) / ASTM E 108 02/14/12 11 CA40912 ASTM D 3462 / TAS 107 (ASTMD 3161) / ASTM E log 11/30/11 LINIITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION I. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. LABELING Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". ruantuoaDSCOUNrrn BUILDING PERMIT REQUIREMENTS Application for building permit shall be accompanied by copies of the following: I.I This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. APP0.0VEDI NOA No.: 15-1102.03 Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 3 of 4 DETAIL A DETAIL B 2" 1% END OF THIS ACCEPTANCE APPROVED EXPOSURE NOA No.: 15-1102.03 Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 4 of 4