Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPLICATION INSTRUCTIONS
SMARTSIDE° St. At the time of manufacture, siding meets or exceeds the per- formance standards set forth in ICC-ES-AC321 and has achieved code recognition under ESR-1301, CCNC 11826, APA recognition under PR-N124, and HUD recognition under HUD-MR-1318. For copies of ESR-1301,.call LP Customer Support at 1-800-848-6893 or go online at http://www.ice-es.org/reports/pdf_files/ICC-ES/ ESR-1301.pdf orhttp://www.apawood.org. • Minimum 6 in. clearance must be maintained between siding and finish grade. • Siding applied adjacent to porches, patios, walks, etc. must have a clearance of at least 1 in. above any surface. • Minimum 1. in. clearance at Intersection with roof line • Apply siding in a mannerthat prevents moisture intrusion and water buildup, • All exposed wood substrate must be.sealed in a manner that prevents moisture intrusion and water buildup. • See alternate fastening options for fastening lap siding to SIP. ICF and Steel Frame assemblies. • DO NOT USE STAPLES • SIDING MUST NOT BE IN DIRECT CONTACT WITH MASONRY, CONCRETE, BRICK, STONE, STUCCO OR MORTAR. Store off the ground well supported, on a flat surface, under a roof or separate waterproof covering • Keep siding clean and dry. Inspect prior to application. Precision 38 Series lap maybe installed on studs spaced a maximum of 16 in. O.C. See alternate fastening option for fastening 38 series 6 in. and 8 in, lap on studs spaced a maxi- mum of 24 in. O.C. Precision 76 Series lap may be installed on studs spaced a maximum of 24 in. O.C. In all Installations over masonry or concrete walls, the wall shall be furred out and open at the top and bottom of the wall to allow for convective ventilation between framing spaced 16 in. O.C. The framing shall be.of adequate thickness to accept 1-1/2 inches of nail penetration. A properly installed breath- able water-resistant barrier is required between the siding and masonry or concrete walls. PRIMED LAP SIDING Lucie County r • Moisture control and moisture vapor control are critical. elements of proper housing design. Check your local, building codes for application procedures for handling moisture and water vapor in your area. When using wet blown cellulose insulation, the insulation must not be in direct contact with the siding and it must be allowed to dry a minimum of 24 hours or longer if specified by the insulation manufacturer. As with all wood products, do not apply engineered wood siding to a structure having excessive moisture conditions such as drying concrete, plaster orwet blown cellulose insulation. If suchconditions exist, the building should be well ventilated to allow it to dry prior to the application of the siding. Siding must not be applied to green or crooked structural framingmembers. ,Do not apply siding over rain -soaked or buckled sheathing materials. ' Gutters are recommended for control of roof water run off. SECONDARVWATER- RESISTANTBARRIER `• A properly installed breathable water -resistive barrier is required behind the siding. Consult your local building code for details. LP will assume no responsibility for water penetration. Seal all gaps with a high -quality, non -hardening, paintable sealant. Follow the sealant manufacturer's instructions for application. Use a high -quality exterior sealant meeting the ASTM C920, minimum Class 25 sealant. D• DOORS OPENINGS • All openings must be properly sealed orflashed in a manner that prevents moisture intrusion or buildup. Several examples that accomplish this are shown on the following pages. -Kici(-OUT FLASHING • Install kick -out flashing'to direct the water into the gutter • Install step flashing with minimum 4 in. upper leg • Properly integrate flashing with the secondarywater-resistive barrier. Use, housewrap, flashing tape, z-flashing, or other items as needed to maintain the counterflashing principle. • 00 NOT extend the siding or trim into the kick -out flashing or gutter • Maintain a clearance between the end of the, gutter and the adjoining wall to allow for proper maintenance of the siding • Prime and paint ALL exposed cut edges LP Siding Minimum 1" clearance between trim and roofing Clean rain gutter APPLICATION INSTRUCTIONS (CONT.) INSTRUCTIONSFINISHING 00 Prime and paint all exposed surfaces including all drip edges or where water will hang. • Apply finish coat as soon as possible or within 180 days of application. High -quality acrylic latex paint, specially formulated for use on wood and engineered wood substrates, is highly recommended. Semi -gloss orsatin finish oil or alkyd paints are acceptable. For flat alkyd paint, please check with the coating manufacturer for their recommendations for use on composite wood siding. • Follow the matingmanufacturer's application and maintenance instructions, 00 NOT USE • Semi -transparent and transparent stains. • Shake and shingle paints. • Vinyl -based resin formulas such as vinyl acetate, PVA, vinyl acetate/acrylic copolymer paints. HANDLE PREFINISHEO LP SMARTSIDE PRODUCTS WITH EXTREME CARE DURING STORAGE AND APPLICATION. TOUCH UP ANY DAMAGE TO THE FINISH THAT MAY OCCUR DURING APPLICATION PER PREFINISHERS SPECIFICATIONS. I IYNILIIVU IIVJIHULIIUNS • LP SmartSide 76 Series lap siding may be attached directly to framing members spaced up to a maximum of 24 in. O.C. • LP SmartSide 38 Series lap siding may be attached directly to framing members that are spaced up to a maximum of 16 in. O.C. • Check your local building code before starting to install the sid- ing to confirm If wall sheathing is required. • Siding joints should be staggered over successive courses. For installation with or without wood structural panels, joints must occur over stud locations. Siding shall be installed with top (blind) nailing, with the nails placed 3/8 in. from either end and a minimum of 3/4 in. from - Do not run trim or siding inside the top edge of the board. Fasteners will be exposed on siding of the kick outflashing located immediately below window sills, fascia boards, and horizontal trim. Fasteners below window sill shall be spaced a maximum of 8 in. O.C. Trim should be thick enough so the siding does not extend beyond the face of the trim. Trim and fascia must be applied in a manner that will not allow moisture intrusion or water buildup, LP° SmartSide° siding is not designed and/or manufactured to be used as trim or fascia. LP Smart5ide trim and fascia are available in a variety of dimensions. • LP SmartSide lap siding is not designed and/or manufactured to be installed vertically. • Overlap successive courses of siding a minimum of 1'in. SmartLock Overlap B Blind Fastening in. nail lacing all SmartLock lap 1g consistent with specifications lese installation ructions APPLICATION INSTRUCTIONS (CONT.) CONDITION CORRECTION Snug_ _ (a OK Flush (06 I OK Visible fiber ® Paint Countersunk+/s-+/, rr+._ � Apply sealant Countersunkmore I Apply sealant and — than +/e in. re -nail • Use minimum 8d (0.113 in. shank diameter), hot -dipped galva- nized nail with a 0,297 in. diameter head. • All exposed face nails must be caulked and sealed in a manner that prevents moisture intrusion and water buildup. • Penetrate structural framing or wood structural panels and structural framing a minimum of 1-1/2 in. • Nail from the center of the siding toward the ends, or from one end to the other end. NEVER nail from the ends of the siding toward the middle. • Shim siding at studs as needed, to avoid drawing siding against uneven walls. Do not overdrive nails. Nail head should seat firmlyto face of siding but not be overdriven to distort the siding surface. • For information on fastening LP SmartSide products in high wind speed areas, referto ICC-ES Report ESR-1301 or APA PR-N124. Alternative Fastening Option for (strand) over Wood Structural Panels and.24 in. O.C. Stud Spacing • Limited to 6 in, and 8 in, wide lap siding. • Wood structural panels must be a minimum 7/16 Category with an APA Trademark that contains the consensus Standard DOC PS 2. • 38 Series, Precision lap must be fastened with: • Minimum #8 hot dip galvanized tapered head wood screw with a 0.270 in. diameter head, spaced a maximum of 12 in. O.C. with 1-1/2 in. screw penetration Into each stud or... • Minimum 6d (0,091 in. shank diameter) hot dip galvanized ring shank nail with a 0.200 in, diameter head, spaced a maxi- mum of 8 in. O.C. with 1-1/2 in. nail penetration into each stud. Alternative Fastening Options over SIP Assemblies Wood structural panels must be a minimum 7/16 Categorywith an APA Trademark that contains the consensus standard DOC PS 2. 38 Series Precision lap must be fastened with: • Minimum #8 hot dip galvanized tapered head wood screw with a 0,270 in. diameter head, spaced a maximum of 12 in. D.C. or.. • Minimum 6d (0.091 in. shank diameter) hot dip galvanized ring shank nail with a 0.200 in. diameter head, spaced a maximum of 8 in. O.C. 76 Series Precision lap must be fastened with: Minimum #8 hot dip galvanized tapered head wood screw with a 0,270 in. diameter head, spaced a maximum of 16 in. O.C. or... Minimum 6d (0.091 in. shank diameter) hot dip galvanized ring shank nail with a 0.200 in. diameter head, spaced a maximum of 12 in. O.C. Alternative Fastening Option over ICF Assemblies • 38 and 76 Series Precision lap must be fastened with: • Minimum #8 hot dip galvanized tapered head self -drilling screw with a 0.270. in. diameter head. • Minimum penetration of 3/8 In. beyond the thickness of the nailing flange. • Larger screws may be required. bythelCFManufacturer based on the following minimum withdrawal requirements. • Minimum withdrawal value of the lCFnailing flange must be SO Ibs, with a maximum 12 in. O.C. screw spacing. • Minimum withdrawal valueofthe lCFnailing flange ;must be 31 Ibs, with a maximum 6 in, O.C.screw spacing. Alternative Fastening Options over Corrosion Resistant Steel Stud Framing Minimum withdrawal value of the steel framing must be 50lbs. Refer to the framing manufacturer's evaluation report. 38 Series Precision lap must be fastened with; • Steel stud spacing a maximum spacing of 16 in. O.C. • Minimum #F8 hot dip galvanized tapered head self -drilling screwwith 0.270In. diameter head. • Minimum of 5 threads beyond the combined thickness of the siding and framing • Minimum steel framing thickness 0.032 in. or 20 gauge. 76 Series Precision lap must be fastened with: • Steel stud spacing a maximum spacing of 241n. O.C. • Minimum #8 hot dip galvanized tapered head self -drilling screw with a 0,270 in. diameter head. • Minimum ofSthreads ,beyond the combined thickness of the siding and framing. • Minimum steel framing thickness 0,032 in. or20 gauge. CAUTION • Do not force siding into place., • DO NOT USE STAPLES. • Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or prefinished surface. • Where siding butts window trim, door casings and masonry, etc. leave a 3/16 in. gap and seal. Insulated Sheathings LP SmartSide Sidings may be installed over low -compression rigid foam or exterior gypsum. The following precautions most be followed: • Adequate bracing of the wall in accordance with the Interna- tional Codes or other ruling building code is required, • For rigid foam sheathing up to 1 in,.(2S.4 mm) thick, siding maybe nailed directly to the foam sheathing unless a drainage plane is required by the local building code. Nail length must be increased to ensure a minimum 1-1/2 in. (38.1 mm) fastener penetratfon,into the structural framing. • For rigid foam sheathing greater than 1 in. (2SA mm), a minimum 1-1/2 in. (38.1 mm) thick by 3-1/2 in, (88.9 mm) wide vertical strapping or furring strip must be installed over the sheathing to provide a solid, level nailing base for the siding. Thestrapping must he securely fastened to structural framing spaced no greater than 16 in. O.C. (406 mm) with a -minimum nail penetration of 1-1/2 in. (38.1 mm) and a maximum nail spacing no greater than the width of the siding. Louisiana-Pacific will assume no responsibility for any damage or condition arising from the use of rigid foam or exterior gypsum. OVERLAP; CLEARANCE G NAILING SPACE.,,, ,. Min. 3/4 in. nail spacing from top Sheathing Breathable 1 in. min. if required water-resistant overlap � ! -+ barrier Siding must extend contact masonry below plate e Min.6 in. finish grade clearance 1 .. Figure 2 Nail min.3/4 in. from top ar • joints must occur over studs. • A minimum 3/16 in. gap is required at ALL butt joints. • If joint caulking option is selected, seal all gaps at butt joints with@ high -quality exterior sealant meeting the ASTMC920, minimum Class 25 sealant. • If joint moulding option is selected, add the thickness of the web to the gap allowing a net 3/16 in. space for expansion. • If siding Is prefinished by an approved or preferred prefinisher it does not require sealant or joint moulding when backed with minimum 4 in, wide flashing and the ends of the siding are factory finished. APPLICATION INSTRUCTIONS (CONT.) RoCIF rr CHIMNEY CLEARANCE Figure 4 4 in. min. flashing 1 in. min. clearance from roofing Min. 3/16 in. gap Paint bottom edges LP Precision Lap siding may also be installed in compliance with category 8140- Exterior wall siding and sheathing for Wildland Unban Interface (WUI) applications atop LP FlameBlock sheathing. Refer to FlameBlock installation Instructions and product data sheets. All LP lap sidings (both Foundations and Precision) may be installed as exterior siding In Wildland Urban Interface (WUI) applications installed. over one layers/8" Type X gypsum sheathing applied behind the exterior covering or cladding on the exterior side of the framing. They may also be Installed overthe exterior portion of a 1-hourfire-resistive exterior wall assembly designed for exterior fire exposure including assemblies using the gypsum panel and sheathing ,products listed in the Gypsum Association Fire Resistance Design Manual. The Louisiana-Pacific Corporation ("LP") LP SmartSide Siding (the "Products") limited warranty (the "Warranty") applies only to structures on which the Products have been applied, finished and maintained in accordance with the published_ application, finishing and maintenance instructions in effect at the time of application. The failure to follow such application, finishing or maintenance instructions will void the Warranty as to the portion of the Products affected by the variance (the "Affected Products"). LP assumes no liability far any loss or damage sustained bythe Affected Products and is expressly released bythe purchaseror ownerfrom anysuch lass orliability. Any modification of the Warranty's application, finishing or maintenance requirements is void and unenforceable unless approved in writing prior to application by the siding general manager or his designee and a member of the LP Legal Department. For a copy of the warranty or for Installation and technical support, visit the LP SmartSide product support Web site at: www.ipsmartside.com or for add itianal support call 800-450-6,106. WARRANTY REMEDIES ARE NOT AVAILABLE IF REQUIREMENTS ARE NOT FOLLOWED. Cal. Prop 69 Warning: Use of this product may result in exposure to wood dust, known to the State of California to cause cancer. SMARTS IOE• TRIM 8 SIDING ©2014 Loulsiana-Pacific Corporation. All rights reserved. LP and SmartSide are registered trademarks of Louisiana-Pacific Corporation. printed in U.S.A. NOTE: Louisiana-Pacific Corporation periodically updates and revises its product information. To verify that this version is Current, C211800450-6106. LPZ60515 1114 Figure 3 Over Openings Ensure colete paintcmapverage of the drip edge Flash, shim, ...;a'.a.•�v, ..T :. 6 gap 3 Figure 3A Vapor Retarder if required n x by code: •� % Breathable water- resistant barrier APPLICATION INSTRUCTIONS (CONT.) Alternate Butt Joint Treatments joint Moulding Caulked Butt joint Gap 3/16 in. plus thickness Gap 3/16 in. and seal of joint moulding web She in. Figure 313 6 in. minimum smix 3E gap 3/16 in. and seal Inside Corner Detail Figure 3C Figure 30 gap 3/16 in. .and seal Outside Corner Detail