HomeMy WebLinkAboutLETTER - PRODUCT EVALUATION REPORTD❑ Kim & ASSOCIATES, LLC
CONSULTING STRu CTu RAL ENGINEERS
Florida Board of Engineers Certificate of Authorization No. 26887
Product Evaluation Report
Date: October 9, 2017
Florida Product Approval: #FL9190
Product Category: Panel Walls
Product sub -category: Siding
Product Name: LP SmartSide Strand Substrate Siding
LP SmartSdie Fiber Substrate Siding
Manufacturer: LP Building Products
414 Union Street, Suite 2000
Nashville, TN 37219
(800)450-6106
SCANNED
BY
St. Lucie County
Scope:
This product evaluation report issued by Do Kim & Associates, LLC and Do Kim, P.E. for LP Building
Products is based on Florida Department of Business and Professional Regulation Rule 61 G20-3 Method
(2) (b) of the State of Florida Product Approval. Re-evaluation of this product shall be required following
pertinent Florida Building Code modifications or updates.
Do Kim & Associates, LLC and Do Kim, P.E. do not have nor will acquire financial interest in the
company manufacturing or distributing the product or in any other entity involved in the approval process
of the product named herein. This product has been evaluated for use in locations adhering to the Florida
Building Code 6th Edition (FBC).
This Item has been electronically signed and sealed
Do, Kim, P.E. by Do Y. Kim, PE on this date using a Digital
FL #49497 Signature. Printed copies of this document are not
considered signed and sealed and the signature
must be verified on any electronic copies.
2017,10.1914:02:18-04'00'
P.O. Box 10039 813.857.9955
Tampa, FL 33679 Sheet 1 of 6
Dio Kim & AsSOCIATES, LLC
CONSULTING STRUCTURAL ENGINEERS
Supporting Documents
I. Drawings and Reports:
a. Application Instructions, LP SmartSide Siding
b. APA-The Engineered Wood Association Product Report PR-N124, Revised. September
29, 2017.
c. Joint Evaluation Report ESR-1301, ICC Evaluation Service„ LLC, ICC-ES, 800-423-
6587, 562=699-0543, www.icc-es.org and APA Product Report, APA-The Engineered
Wood Association, Tacoma, WA, Reissued February, 2017.
d. ICC-ES Report ESR-3090, ICC Evaluation Service, LLC, ICC-ES, 800-423-6587, 562-
699-0543, www.ice-es.org Issued June, 2017,
e. LP Building Products Technical Note No.014, Installing LP Smartside Trim and Lap
Siding on Concrete or Masonry Walls over Furring Strips in Florida.
2. Testing
a. Approved test lab: Architectural Testing, Inc., 130 Derry Court, York, PA 17406. Test
reports referenced:
i. Report No. 79279.01-122-18 (01/07/08)
1. Testing per Miami -Dade County Checklist #0475 For the Approval of:
Durability of Wood -base Structural Composite Lumber and Panels
2. ASTM D4761-02 Standard Test Methods for Mechanical Properties of
Lumber and Wood -Based Structural Material.
3. ASTM D1716-06 Standard Test Methods for Mechanical Fasteners in
Wood.
ii. Report No. 78294.01-401-18 (12/03/07)
1. TAS 202-94, Criteria for Testing Impact and. Non -Impact Resistant
Building Envelope Components Using Uniform Static Air Pressure
Loading. Design Pressure @ +/-57.6 psf.
2. TAS 203-94, Criteria for Testing Products Subject to Cyclic Wind
Pressure Loading. Design Pressure @ +/-57.6 psf.
b. Test lab: Progressive Engineering, Inc., 58640 State Rd. 15, Goshen, Indiana 46526. Test
reports referenced: ASTM E-330 for tests except for ASTM E-72 for transverse load test.
I. ABTCO, Inc., Exterior Cladding Suction Test, 6/27/94.
2. ABTCO, Inc., Exterior Cladding Suction Test, 8/01/94.
3. ABTCO, Inc.; Exterior Cladding Suction Test, 6/28/94.
4. ABTCO, Inc., Transverse Load Test, Proline Double 5 Lap Siding 16"
o.c. Studs., 10/31/96.
5. ABTCO, Inc., Exterior Cladding Suction Test, Proline Double 5 Lap
Siding 24" o.c. Studs., 11126/96,
6. ABTCO, Inc., Exterior Cladding Suction Test; Proline Double 5 Lap
Siding 16" o.c. Studs., 11/19/96.
7. ABTCO, Inc., Exterior Cladding Suction Test, Proline Double 5 Lap
Siding 16" o.c. Studs., 11/01196.
8. ABTCO, Inc., Exterior Cladding Suction Test, 8" Cedar Lap Siding 24"
o.c. Studs., 12/06/96.
9. ABTCO, Inc., Exterior Cladding Suction Test, 8" Cedar Lap Siding 16"
o.c. Studs., 10/23/96, Revised on 11106196.
10. ABTCO, Inc., ABTCO Cedar -Lap Wall Panel Test, 8/02/94.
11. ABTCO, Inc., ABTCO Cedar -Lap Wall Panel Test, 8/04/94.
P.O.,Box 10039 813.857.9955
Tampa, FL 33679 Sheet 2 of 6
DO Kim & ASSOCIATES, LLC.
CONSULTING STRUCTURAL ENGINEERS
c. Test lab: Stork Twin City Testing Corporation, 662 Cromwell Ave., Saint Paul, MN
5 5 114. Test reports referenced:
i. Report No. 30160 08-99292.04 (12/24/08)
1. Fourth Quarter 2008 Testing of Hardboard Siding Products,
Manufacturer:04, prepared for Composite Panel Association. Testing
.conducted in accordance with ANA A135.6-2006, and ASTM D1037.
d. NTA Inc., 257 East Randolph Street, Nappanee, Indiana 48550. Test reports referenced:
i. Test Report: LP (NC)123014-8 Issued April 28, 2015.
1. Uniform Load Tests per ICC-ES AC321, Secion 4.4.
2. Smartside Hardboard siding tested dry and wet.
ii. Test Report: LP (NC)123014-10 Issued April 28, 2015.
1. Fastener Head Pull -Through Tests per ICC-ES AC321, Secion 4.6.
2. Smartside Hardboard siding tested dry and wet.
3. Calculations
a. Standards referenced:
i. [CC Evaluation Service, Inc. Acceptance Criteria for Treated -Engineered -Wood
Siding, AC321, November 1, 2005 (strand substrate engineered wood products).
ii. ANSI A135.6-2012 Engineered Wood Siding, June 5, 2012 standard (see
Certificate of Standards Equivalency) has been utilized for performance
calculations for fiber substrate engineered wood products.
4. LP SmartSide Model Product Names
a. LP SmartSide is manufactured in Strand Substrate and Fiber Substrate. Previous product
names of Architectural Collection and Foundations Collection models have been renamed
SmartSide Siding (fiber substrate). Precision Series models have been renamed
SmartSide Siding (strand substrate).
i. Architectural Collection Cedar Shake Lap (fiber substrate)
ii. Architectural Collection Bold Lap (fiber substrate)
iii. Foundations and Architectural Collection Lap (fiber substrate)
iv. Foundations and Architectural Collection Panel (fiber substrate)
v. Precision Series Lap (strand substrate)
vi. Precision Series Panel (strand substrate)
P.O. Box 10039 813.857.9955
Tampa, FL 33679 Sheet 3 of 6
Do Kim & ASSOCIATES, LLC
CONSULTING STRUCTURAL ENGINEERS
5. Installation Instructions
a. Strand Substrate Models:
i. Installation fastening requirements as outlined in the APA PR-N124 and Joint
Evaluation Report ESR-1301 documents have been reviewed and evaluated by
Do Kim, P.E. based on comparative and/or rational analysis and has been
determined to be in accordance to accepted engineering practice. Installation
loads per APA PR-N 124 and Joint Evaluation Report ESR-1301 shall, be the
minimum design pressures as determined in accordance to the FBC 6d' Edition
(FBC).
b. Fiber Substrate Models:
i. Installation fastening requirements as outlined in the ICC-ES Report ESR-3090
document have been reviewed and evaluated by Do Kim, P.E. based on
comparative and/or rational analysis and has been determined to be in accordance
to accepted engineering practice. Installation loads per ICC-ES Report ESR-3090
shall be the minimum design pressures as determined in accordance to the FBC
6'" Edition (FBC).
P.O. Box 10039 813.857.9955
Tampa, FL 33679 Sheet 4 of 6
Do Kim Sc ASSOCIATES, LLC
CONSULTING STRUCTURAL ENGINEERS
6. Applicable FBC Sections
a. Chapter 14 Exterior Walls
i. Section 1404.3.2 Hardboard Siding
I Section 1405.2 Weather Protection
iii. Section 1405.5 Wood Veneers
iv. Section 1405.17 Fastening
b. Chapter 16 Structural Design
i. Section 1604.3.1 Deflections
ii. Section 1609.1 Applications
iii. Section 1616.3.1 HVHZ Allowable Deflections
c. Chapter 23 Wood
i. Section 2304.6 Exterior Wall Sheathing
ii. Section 2304.6.1 Wood Structural Panel Sheathing
iii. Section'2315.1.11
7. Other
a. Quality Assurance of LP SmartSide Strand Substrate products by APA - The Engineered
Wood Association (FBC Organization #QUA2521)'that manufacturer is. within a quality
assurance program for this product under Rule 61 G20-3.
b. Quality Assurance of LP SmartSide Fiber Substrate products by Composite Panel
Association (FBC Organization #QUA10765) that manufacturer is within a quality
assurance program for this product under Rule 61 G20-3. .
P.O. Box 10039 813.857.9955
Tampa, FL 33679 Sheet 5 of 6
D❑ Kim & ASSOCIATFs� LLC
CONSULTING STRUCTURAL ENGINEERS
Limitations and Condition of Use
1. This product has been designed and tested in accordance to the Florida Building Code 6`s'Edition
(FBC).
2. No missile impact resistance testing has been conducted.
3. Each product listed above shall be installed in strict compliance with its respective Product
Evaluation Document along with all components noted herein.
4. Use of each product shall be in strict accordance with its Product Approval Evaluation
Documents.
5. Fire-resistant construction: Wood structural panels that are not fire -treated have been shown to
meet a Class III (or C) category for flame spread. Where otherwise specified, fire-resistant
construction shall be in accordance with the a recommendations in APA Product Guide: Fire -Rated
Systems, Form W305.
6. Deflection limits and allowable spans per Product Approval Evaluation Documents are in
accordance to L/120 in non-HVHZ per Chapter 16 Table 1604.3 deflection limits. Deflection
limits and allowable spans per Product Approval Evaluation Documents are in accordance to
L/180 in HVHZ per Chapter 16 Section 1616.3.1 deflection limits.
7. All supporting host structures shall be designed to resist all superimposed loads.
8. All components which are permanently installed shall be protected against corrosion,
contamination, and other such damage,
P.O. Box 10039 813.857.9955
Tampa, FL 33679 Sheet 6 of 6