HomeMy WebLinkAboutNOAMIAM12M
Em --
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) nf) w4w.miamidade.eov/econom
en a
1 Campus Drive DEC 0 5 Z018 SCANNED
Parsippany, NJ 07054 BY
ST. Lucie County, Permltting St. Lucie Coun4g/
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ). r
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke; modify, or suspend the use of such product or material within their jurisdiction. RER reserves the
right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this
product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Ruberoid®Modified Bitumen Roof System for Cementitious Wood Fiber Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 15-1020.05 and consists of pages 1 through 16.
The submitted documentation was reviewed by Jorge L. Acebo.
MIAMI•DADE COUNTY
EI4 1
File Copy
NOA No.: 18-0919.11
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 1 of 16
ROOFING SYSTEM APPROVAL
Category:
Roofing
Sub -Category:
Modified Bitumen
Material:
APP/SBS
Deck Type:
Cementitious Wood Fiber
Maximum Design Pressure:
-82.5 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED
OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
GAFGLAS® Ply 4
39.37"
ASTM D2178
Smooth surfaced asphaltic ply sheet
(1 meter) Wide
reinforced with fiberglass mat.
Tri-Ply® ply 4 Ply Sheet
39.37"
ASTM D2178
Smooth surfaced asphaltic ply sheet
(1 meter) Wide
reinforced with a fiberglass mat.
GAFGLAS®
39.37'.'
ASTM D2178
Smooth surfaced asphaltic ply sheet
F1exPly"" 6
(1 meter) Wide
reinforced with fiberglass mat.
GAFGLAS® #75 Base Sheet
39.37"
ASTM D4601
Smooth asphaltic base or base/ply sheet
(1 meter) Wide
reinforced with fiberglass mat.
Tri-Ply® #75 Base Sheet
39.37"
ASTM D4601
Smooth asphaltic base or base/ply sheet
(1 meter) Wide
reinforced with a fiberglass mat.
GAFGLAS® #80 Ultima""
39.37"
ASTM D4601
Smooth asphaltic base or base/ply sheet
Base Sheet
(1 meter) Wide
reinforced with fiberglass mat.
GAFGLAS® Stratavent®
39.37"
ASTM D4897
Smooth surfaced asphaltic perforated
Perforated Venting Base
(1 meter) Wide
venting base sheet reinforced with
Sheet
fiberglass mat.
GAFGLAS® Stratavent®
39.37"
ASTM D4897
Smooth surfaced asphaltic nailable venting
Nailable Venting Base Sheet
(1 meter) Wide
base sheet reinforced with fiberglass mat.
Bottom side surfaced with granules.
Ruberoid® HW 25 Smooth
39.37"
ASTM D6163
Smooth surfaced torch applied SBS base
(1 meter) Wide
or ply sheet reinforced with a fiberglass
mat.
Ruberoid®HW Smooth
39.37"
ASTM D6164
Smooth surfaced torch applied SBS base or
(1 meter) Wide
ply sheet reinforced with a polyester mat.
Ruberoid® HW Granule
39.37"
ASTM D6164
Granule surfaced torch applied SBS cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® HW Granule FR
39.37"
ASTM D6164
Fire retardant granule surfaced heat -welded
(1 meter) Wide
SBS cap sheet reinforced with a polyester
mat.
Ruberoid® HW Plus Granule
39.37"
ASTM D6164
Granule surfaced torch applied SBS cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® HW Plus Granule
39.37"
ASTM D6164
Fire retardant granule surfaced torch
FR
(1 meter) Wide
applied SBS cap sheet reinforced with a
polyester mat.
Ruberoid® EnergyCap" HW
39.37"
ASTM D6164
Fire retardant granule surfaced heat -welded
Plus Granule FR
(1 meter) Wide
SBS cap sheet reinforced with a polyester
mat. Cap sheet is factory coated with
EnergyCote'.
NOA No.: 18-0919.11
MIAMI-DADE COUNTY
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 2 of 16
Test
Product
Product
Dimensions
Specification
Description
Ruberoid® Torch Smooth
39.37"
ASTM D6222
Smooth surfaced torch applied APP base or
(1 meter) Wide
ply sheet reinforced with a polyester mat.
Tri-Ply® APP Smooth
39.37"
ASTM D6222
Smooth surfaced torch applied APP cap,
Membrane
(1 meter) Wide
base or ply sheet reinforced with a
polyester mat.
Ruberoid® Torch Granule
39.37"
ASTM D6222
Granule surfaced torch applied APP cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Tri-Ply® APP Granule Cap
39.37"
ASTM D6222
Granule surfaced torch applied APP cap
Sheet
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® Torch Plus
39.37"
ASTM D6222
Fire retardant granule surfaced torch
Granule FR
(1 meter) Wide
applied APP cap sheet reinforced with a
'
polyester mat.
Ruberoid® EnergyCap
39.37"
ASTM D6222
Fire retardant granule surfaced torch
Torch Plus Granule FR
(1 meter) Wide
applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with EnergyCote'.
Ruberoid® EnergyCap"'
39.37"
ASTM D6222
Fire retardant granule surfaced torch
Torch Granule FR
(1 meter) Wide
applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with EnergyCote'.
Ruberoid® 20 Smooth
39.37"
ASTM D6163
SBS polymer -modified asphalt base or ply
1
(1 meter) Wide
sheet reinforced with a fiberglass mat.
Ruberoid® 30 Granule
39.37"
ASTM D6163
Granule surfaced mop applied SBS cap
(1 meter) Wide
sheet reinforced with a fiberglass mat.
Ruberoid® 30 Granule FR
39.37"
ASTM D6163
Fire retardant granule surfaced mop applied
(1 meter) Wide
SBS cap sheet reinforced with fiberglass
mat.
Ruberoid® 30 Plus Granule
39.37"
ASTM D6163
Fire retardant granule surfaced mop applied
FR
(1 meter) Wide
SBS cap sheet reinforced with fiberglass
mat.
Ruberoid® Mop Granule
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Tri-Ply® SBS Granule Cap
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
Sheet
(1 meter) Wide
sheet reinforced with a polyester mat.
Intec Flex PRF
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® Mop Smooth
39.37"
ASTM D6164
Smooth surfaced mop applied SBS base or
(1 meter) Wide
ply sheet reinforced with a polyester mat.
Ruberoid® Mop Smooth 1.5
39.37"
ASTM D6164
Smooth surfaced mop applied SBS base or
(1 meter) Wide
ply sheet reinforced with a polyester mat.
Ruberoid® Mop Plus Smooth
39.37"
ASTM D6164
Smooth surfaced mop applied SBS base or
(1 meter) Wide
ply sheet reinforced with a polyester mat.
Ruberoid® Mop Plus Granule
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® Mop Plus Granule
39.37"
ASTM D6164
Fire retardant granule surfaced mop applied
FR
(1 meter) Wide
SBS cap sheet reinforced with a polyester
mat.
NOA No.: 18-0919.11
niarnr_9 8 ouNrr Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 3 of 16
Test
Product
Product
Dimensions
Specification
Description
Ruberoid;l EnergyCap' Mop
39.37"
ASTM D6164
Fire retardant granule surfaced mop applied
Plus Gratiule FR
(1 meter) Wide
SBS cap sheet reinforced with a polyester
mat. Cap sheet is factory coated with
EnergyCote'.
Ruberoid® Mop Granule FR
39.37"
ASTM D6164
Fire retardant granule surfaced mop applied
(1 meter) Wide
SBS cap sheet reinforced with a polyester
mat.
Ruberoid" EnergyCap'" 30
39.37"
ASTM D6163
Fire retardant granule surfaced mop applied
Granule FR
(1 meter) Wide
SBS cap sheet reinforced with a fiberglass
mat. Cap sheet is factory coated with
EnergyCote'.
GAFGLAS® Mineral-
39.37"
ASTM D3909
Granule surfaced asphaltic cap sheet
Surfac4Cap Sheet
(1 meter) Wide
reinforced with fiberglass mat.
Tri-Ply® BUR Granule Cap
39.37"
ASTM D3909
Granule surfaced asphaltic cap sheet
Sheet
(1 meter) wide
reinforced with a fiberglass mat.
GAFGLAS® EnergyCap''
39.37"
ASTM D3909
Granule surfaced asphaltic cap sheet
Mineral -Surfaced Cap Sheet
(1 meter) Wide
reinforced with fiberglass mat. Cap sheet
is factory coated with EnergyCote'".
Matrix''1102 SBS Membrane
3, 5 or
ASTM D3019
Fiber reinforced rubberized cold -applied
Adhesive
55 gallons
adhesive for modified bitumen roof
systems.
Matrix '"'307 Premium
3, 5 or
ASTM D41
Asphalt concrete primer used to promote
Asphalt Primer
55 gallons
adhesion of all types of asphalt -based
roofing materials.
TOPCOArMembrane
1, 5 or
ASTM D6083
Water -based elastomeric coating
55 gallons
United Coatings' Roof Mate
1, 5 or
ASTM D6083
Water -based elastomeric coating
TCM Coating
55 gallons
TOPCOAT®
5 or 55 gallons
ASTM D6083
Solvent -based thermoplastic rubber sealant
Surface Seal SB
designed to protect and restore aged roof
surfaces and to increase roof reflectivity.
United Coatings" Surface
5 or 55 gallons
ASTM D6083
Solvent -based thermoplastic rubber sealant
Seal SB Roof Coating
designed to protect and restore aged roof
surfaces and to increase roof reflectivity.
TOPCOAT® MB Plus
5 or 55 gallons
Proprietary
Water based, low VOC primer designed to
block asphalt bleed -through.
United Coatings' Roof Mate
5 or 55 gallons
Proprietary
Water based, low VOC primer designed to
MB Plus Coating
block asphalt bleed -through.
FlexSeal" Sealant
1 gallon,
TAS 139
Solvent -based elastomeric sealant.
5 gallons or
1 qt. tube
NOA No.: 18-0919.11
MIAMI•DAD' COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 4 of 16
APPROVED INSULATIONS:
TABLE 2
Product Name
Product Description
Manufacturer
(With Current NOA)
EnergyGuard'
Polyiso Insulation
Polyisocyanurate foam insulation
GAF
EnergyGuard''
Tapered Polyiso Insulation
Polyisocyanurate foam insulation
GAF
EnergyGuard'
Ultra Polyiso Insulation
Glass -faced polyisocyanurate
GAF
foam insulation.
EnergyGuard'
RA Polyiso Insulation
Polyisocyanurate foam insulation
GAF
EnergyGuard'
RA Tapered Polyiso
Polyisocyanurate foam insulation
GAF
Insulation
EnergyGuard'
RH Polyiso Insulation
Polyisocyanurate foam insulation
GAF
EnergyGuard'
RH Tapered Polyiso
Polyisocyanurate foam insulation
GAF
Insulation
EnergyG,bard"
RN Polyiso Insulation
Polyisocyanurate foam insulation
GAF
EnergyGuard'
RN Tapered Polyiso
Polyisocyanurate foam insulation
GAF
Insulation
EnergyGuard'
Perlite Roof Insulation
Perlite insulation board.
GAF
EnergyGuard'
Perlite Recover Board
Perlite recover board
GAF
SECUROCK"
Gypsum -Fiber Roof Board
Gypsum board
United States Gypsum Corp.
Structodek" High
Density Fiber Board Roof
High density fiberboard
Blue Ridge Fiberboard, Inc.
Insulation
DensDeck" Roof
Board
Gypsum board
Georgia-Pacific Gypsum LLC
DensDeck" Prime
Roof Board
Gypsum board
Georgia-Pacific Gypsum LLC
APPROVED FASTENERS:
Fastener Product
Number Name
1 Drill -Tee'" Locking
Impact Nail
TABLE 3
Product Description
Dimensions
Preassembled fastener/plate
Fastener:
unit for base ply and
Various
insulation attachment to
lengths
cementitious wood fiber,
Plate: 2.7"
poured gypsum and
diameter
lightweight insulating
concrete decks.
Manufacturer
(With Current NOA)
GAF
NOA No.: 18-0919.11
MIAMI•DAD; COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 5 of 16
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum
design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
MIAMINOA No.: 18-0919.11
M, 9 COUNTY
. •. •, , Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 16 of 16
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Date
FM Approvals
FM 4470
3014547
05/22/03
FM 4470
3040738
05/18/12
FM 4470
3042887
11/14/11
FM 4470
3044688
03/01/12
FM 4470
3048066
12/13/13
FM 4470
3031294
06/21/11
FM 4470
ODOA8.AM
07/09/97
FM 4470
OY9Q5.AM
04/01/98
FM 4470
2B8A4.AM
07/02/97
FM 4470
3B9Q1.AM
01/08/98
FM 4470
OT4ALAM
12/14/05
FM 4470
FM 797-10228-267
01/15/15
FM 4470
RR203450
12/04/15
FM 4470
FM Letter
04/11/13
FM 4470
FM Letter
09/15/15
Exterior Research & Design, LLC
TAS 117
4670.03.01-1
09/20/01
Trinity I ERD
ASTM D6163
G6850.08.08
08/01/08
ASTM D6164
G6850.08.08-RI
04/14/11
ASTM D6222
G6850.10.08
10/06/08
ASTM D6222
G6850.11.08
02/17/09
ASTM D6222
G30250.02.10-2
02/11/10
ASTM D3909
G30250.02.10-3-R2
06/03/15
ASTM D6164
G31360.03.10
03/31/10
ASTM D6164
G33470.01.11
01/13/11
ASTM D6163
G34140.04.11-2
04/25/11
ASTM D4601
G34140.04.11-4-R2
06/04/15
ASTMD4879
G34140.04.11-5-R3
06/04/15
ASTM D6222
G40620.07.12-2
07/17/12
ASTM D6163
G40630.01.14-1
01/06/14
ASTM D6164
G40630.01.14-2A
01/07/14
ASTM D6164
G40630.01.14-2A-1-Rl
04/10/14
ASTM D6164
G40630.01.14-2B-Rl
01/16/15
ASTM D6164
G40630.01.14-2C
01/07/14
ASTM D6164
G40630.03.14
03/06/14
ASTM D6222
G43190.03.14-1
03/06/14
ASTM D6222
G43190.03.14-2
03/06/14
ASTM D6222
G43190.05.14-R1
05/20/14
ASTM D6222
G43190.11.13-1
11/15/13
ASTM D3909
G43610.01.14
01/22/14
ASTM D6163
G46160.02.15
02/1'2/15
ASTM D6163
G46160.02.15-2D-1
02/09/16
ASTM D6163
G46160.03.15
03/1-1/15
ASTM D6163
G46160.09.14-2A
09/09/14
ASTM D6164
G46160.09.14-3A
09/09/14
ASTM D6164
G46160.09.14-313
09/09/14
NOA No.: 18-0919.11
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 6 of 16
EVIDENCE SUBMITTED: (CONTINUED
Test Agency
Name
Report
Date
Trinity I ERD
ASTM D6164
G46160.09.14-3C
09/09/14
ASTM D6164
G46160.12.14-3E
12/29/14
ASTM D3909
SC6870.08.14-R1
09/04/14
ASTM D2178
SC9700.08.15-R1
08/23/11
ASTMD6163
SC10680.05.16
05/10/16
ASTM D6164
SC13105.03.17-R1
03/23/17
ULLLC
UL790
R1306
08/21/18
PRI Construction Materials
TAS 139
GAF-122-02-01
05/07/06
Technologies LLC.
ASTM D2178
GAF-314-02-01
08/23/11
ASTM D2178
GAF-315-02-01
08/23/11
ASTM C1289
GAF-369-02-01
10/22/12
ASTM C1289
GAF 417-02-01
05/28/13
ASTM C1289
GAF-464-02-01
02/06/14
ASTM D6083
GAF-498-02-01
09/16/16
ASTM D6083
GAF-499-02-01
03/12/14
ASTM D6083
GAF-500-02-01
03/12/14
ASTM C1289
GAF-629-02-01
03/01/16
TAS 139
GAF-671-02-01
07/01/16
ASTM D6083
GAF-692-02-01
03/14/16
IRT-ARGON, Inc.
TAS 114
02-026
07/26/02
NOA No.: 18-0919.11
MIAMIDAD; COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 7 of 16
i
APPROVED ASSEMBLIES
Membrane Type: SBS Heat Weld
Deck Type 5I: Cementitious Wood Fiber, Insulated
Deck Description: Cementitious Wood Fiber
System Type A(1): Anchor sheet mechanically fastened; all layers of insulation adhered with approved
asphalt.
Anchor Sheet: One ply of GAFGLAS' #75 Base Sheet, Tri-Ply' #75 Base Sheet, GAFGLAS' #80
Ultima'' Base Sheet, GAFGLAS® Stratavent' Nailable Venting Base Sheet, Ruberoid®
HW 25 Smooth, Ruberoid' HW Smooth, Ruberoid® 20 Smooth or Ruberoid' Mop
Smooth mechanically fastened with Drill-Tec' Locking Impact Nail at a 3" side lap 9"
o.c. and in two rows staggered in the center of the sheet 12" o.c.
All General and System Limitations shall apply.
One or more layers of any of the following insulations.
(Optional) Base Layer Insulation Fasteners Fastener
(Table 3) Density/fe
EnergyGuard" Polyiso Insulation, EnergyGuard'' Ultra Polyiso Insulation,
EnergyGuard' RH Polyiso Insulation
Minimum 1" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck' Roof Board, SECUROCK' Gypsum -Fiber Roof Board
Minimum 1/4" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within
the EVT range and at a rate of 20-40 lbs./100 ft. Please refer to Roofing Application Standard RAS 117
for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate. GAF requires
either a ply of GAFGLAS' Stratavent' Perforated Venting Base Sheet laid dry or a layer of
EnergyGuard'" Perlite Roof Insulation or wood fiber overlay board on polyisocyanurate insulation
applicailions.
Base Sheet: One or more plies of Ruberoid' HW 25 Smooth or Ruberoid' HW Smooth adhered to
the insulation in a full mopping of approved asphalt applied within the EVT range and at
a rate of 20-40 lbs./sq. (See General Limitation #4)
Membrane: One or more plies of Ruberoid' HW 25 Smooth, Ruberoid' HW Smooth, Ruberoid' HW
Granule, Ruberoid' HW Granule FR, Ruberoid' HW Plus Granule, Ruberoid' HW Plus
Granule FR or Ruberoid' EnergyCapn' HW Plus Granule FR applied according to
manufacturer's instructions.
NOA No.: 18-0919.11
Mia,rn-nnoe COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 8 of 16
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied in accordance with manufacturer's
instructions. Any coating listed below used as a surfacing must be listed with a
current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
Approved asphalt at 60 lbs./sq.
2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or
GAFGLAS' EnergyCap'' Mineral -Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. TOPCOAT' Surface Seal SB or United Coatings" Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings" Roof Mate MB Plus Coating applied at a
minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT"
Membrane or United Coatings'" Roof Mate TCM Coating applied in one or more coats
at a minimum rate of 1.0 gal./sq. per coat.
4. A fibered aluminum coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -82.5 psf. (See General Limitation #7)
NOA No.: 18-0919.11
MIAMI-DAD, COUNTY Expiration Date: 11/06/23
FUMApproval Date: 11/01/18
Page 9 of 16
Membrane Type: APP/SBS Heat Weld
Deck Type 5I: Cementitious Wood Fiber, Insulated
Deck Description: Cementitious Wood Fiber
System Type A(2): Anchor sheet mechanically fastened; all layers of insulation adhered with approved
asphalt.
All General and System Limitations shall apply.
Anchor Sheet: One ply of GAFGLAS' #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80
Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet,, Ruberoid'
HW 25 Smooth, Ruberoid® HW Smooth, Ruberoid® 20 Smooth, Ruberoid® Mop
Smooth mechanically fastened with Drill-Tec''I Locking Impact Nail at a 3" side lap 9"
o.c. and in two rows staggered in the center of the sheet 12" o.c.
One or more layers of any of the following insulations
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuard' Polyiso Insulation, EnergyGuard"" Ultra Polyiso Insulation,
EnergyGuard' RH Polyiso Insulation EnergyGuard"' RA Polyiso Insulation,
EnergyGuard'T' RN Polyiso Insulation
Minimum 1.3" thick N/A N/A
Structodek® High Density Fiber Board Roof Insulation, EnergyGuard' Perlite Recover Board,
EnergyGuard" Perlite Roof Insulation
Minimum %" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within
the EVT range and at a rate of 20-40 lbs./100 ft. Please refer to Roofing Application Standard RAS 117
for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate. GAF requires
either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a layer of
EnergyGuard"' Perlite Roof Insulation or wood fiber overlay board on polyisocyanurate insulation
applications.
Base Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® FlexPly""
6, GAFGLAS® #75 Base Sheet, Tri-Ply® 475 Base Sheet, GAFGLAS® #80 Ultima'° Base
Sheet, Ruberoid® 20 Smooth, Ruberoid' Mop Smooth, Ruberoid® Mop Smooth 1.5,
Ruberoid' Mop Plus Smooth adhered to the insulation in a full mopping of an approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General
Limitation #4)
Or
GAFGLAS' Stratavent' Perforated Venting Base Sheet loose laid dry followed by a
mopped ply sheet listed below.
Ply Sheet: (Required over GAFGLAS' Stratavent' Perforated Venting Base Sheet) One or
(Optional) more plies of GAFGLAS' Ply 4, Tri-Ply' Ply 4 Ply Sheet, GAFGLAS' FlexPly' 6,
GAFGLAS' 480 Ultima"° Base Sheet or Ruberoid' 20 Smooth adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
NOA No.: 18-0919.11
MiAMMADe COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 10 of 16
Membrane: One or more plies of Ruberoid® Torch Smooth, Tri-Ply® APP Smooth Membrane,
Ruberoid' Torch Granule, Tri-Ply® APP Granule Cap Sheet, Ruberoid' Torch Plus
Granule FR, Ruberoid' EnergyCap" Torch Plus Granule FR or Ruberoid' EnergyCap'
Torch Granule FR torch applied according to manufacturer's application instructions.
Or
One or more plies of Ruberoid' HW 25 Smooth, Ruberoid' HW Smooth, Ruberoid' HW
Granule, Ruberoid' HW Granule FR, Ruberoid' HW Plus Granule, Ruberoid' HW Plus
Granule FR or Ruberoid' EnergyCap"' HW Plus Granule FR applied according to
manufacturer's application instructions.
Or
(Only for use over Ruberoid' 20 Smooth Ply Sheet) GAFGLAS' Mineral -Surfaced
Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral -
Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs. sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied in accordance with manufacturer's
instructions. Any coating listed below used as a surfacing must be listed with a
current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
Approved asphalt at 60 lbs./sq.
2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or
GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating applied at a
minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT' Membrane
or United Coatings" Roof Mate TCM Coating applied in one or more coats at a
minimum rate of 1.0 gal./sq. per coat.
4. A fibered aluminum coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -82.5 psf. (See General Limitation #7)
MIAMI•DADE COUNTY NOA No.: 18-0919.11
..., , Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 11 of 16
Membrane Type:
SBS/SBS Cold Applied
Deck Type 5I:
Cementitious Wood Fiber, Insulated
Deck Description:
Cementitious Wood Fiber
System Type A(3):
Anchor sheet mechanically fastened; all layers of insulation adhered with approved
asphalt.
Anchor Sheet:
One ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80
Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet, Ruberoid®
HW 25 Smooth, Ruberoid® HW Smooth, Ruberoid® 20 Smooth, Ruberoid® Mop
Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth mechanically
fastened with Drill-Tec' Locking Impact Nail at a 3" side lap 9" o.c. and in two rows
staggered in the center of the sheet 12" o.c.
All General and System Limitations shall apply.
One or more layers of any of the following insulations
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Polyiso Insulation, EnergyGuard'" Ultra Polyiso Insulation,
EnergyGuard'' RH Polyiso Insulation, EnergyGuard'' RA Polyiso Insulation
Minimum 1.3" thick N/A N/A
EnergyGuard' Polyiso Insulation, EnergyGuard'"' Ultra Polyiso Insulation,
EnergyGuard'" RH Polyiso Insulation, EnergyGuard' RN Polyiso Insulation
Minimum 1.4" thick N/A N/A
Structodek® High Density Fiberboard Roof Insulation, EnergyGuard'' Perlite Recover Board,
EnergyGuard" Perlite Roof Board
Minimum''V2" thick N/A N/A
Base or Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck® Roof Board, DensDeck® Prime® Roof Board, SECUROCK® Gypsum -Fiber Roof Board
Minimum''/e" thick N/A N/A
Structodek® High Density Fiberboard Roof Insulation, EnergyGuard' Perlite Recover Board,
EnergyGuard" Perlite Roof Board
Minimum%" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within
the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117
for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate. GAF requires
either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a layer of
EnergyGuard' Perlite Roof Insulation or wood fiber overlay board on polyisocyanurate insulation
applications.
Base Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® FlexPly
6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80 Ultima' Base
Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5,
Ruberoid® Mop Plus Smooth adhered to the insulation in a full mopping of an approved
asphalt applied within the EVT range and at a rate of 20-40 lbs. sq. (See General
Limitation 44)
NOA No.: 18-0919.11
MIAMIHE 0 COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 12 of 16
Base Sheet:
Or
(Continued)
GAFGLAS' Stratavent' Perforated Venting Base Sheet loose laid dry followed by a
mopped ply sheet listed below.
Ply Sheet:
(Required over GAFGLAS® Stratavent® Perforated Venting Base Sheet) One or
(Optional)
more plies of GAFGLAS' Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS' FlexPly' 6,
GAFGLAS' #80 Ultima'" Base Sheet, Ruberoid' 20 Smooth, Ruberoid' Mop Smooth,
Ruberoid' Mop Smooth 1.5, Ruberoid' Mop Plus Smooth adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane:
One or more plies of Ruberoid' 30 Granule, Ruberoid' 30 Granule FR, Ruberoid' 30
Plus Granule FR, Ruberoid' Mop Granule, Tri-Ply' SBS Granule Cap Sheet, Intee Flex
PRF, Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid' Mop Plus
Smooth, Ruberoid' Mop Plus Granule, Ruberoid' Mop Plus Granule FR, Ruberoid'
EnergyCap' Mop Plus Granule FR, Ruberoid' Mop Granule FR or Ruberoid'
EnergyCap' 30 Granule FR adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq. or in MatrixTp° 102 SBS Membrane
Adhesive at an application rate of 1-2 gal./sq.
Or
(Only for use over Ruberoid' 20 Smooth, Ruberoid' Mop Smooth, Ruberoid' Mop
Smooth 1.5 or Ruberoid' Mop Plus Smooth) GAFGLAS' Mineral -Surfaced Cap
Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral -Surfaced
Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range
and at a rate of 20-40 lbs. sq.
Surfacing:
Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied in accordance with manufacturer's
instructions. Any coating listed below used as a surfacing must be listed with a
current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
Approved asphalt at 60 lbs./sq.
2.
GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or
GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3.
TOPCOAT' Surface Seal SB or United Coatings'"' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating applied at a
minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT' Membrane
or United Coatings" Roof Mate TCM Coating applied in one or more coats at a
minimum rate of 1.0 gal./sq. per coat.
4.
A fibered aluminum coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure:
-82.5 psf.(See General Limitation #7)
MIAMI•DADE COUNTY
[...I 1
NOA No.: 18-0919.11
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 13 of 16
Membrane Type:
APP/SBS Heat Weld
Deck Type 5:
Cementitious Wood Fiber, Non -Insulated
Deck Description:
Cementitious Wood Fiber
System Type E(1):
Anchor sheet mechanically fastened
All General and System Limitations shall apply.
Anchor Sheet:
Install one ply of GAFGLAS' 975 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS'
#80 Ultima'°' Base Sheet, GAFGLAS® Stratavent' Nailable Venting Base Sheet,
Ruberoid' HW 25 Smooth, Ruberoid® HW Smooth, Ruberoid' 20 Smooth or
Ruberoid' Mop Smooth mechanically fastened with 1.8" Drill -Tee' Locking Impact
Nail fastened at 9" o.c. at the 3" side lap and in two 12" o.c. staggered rows in the field.
Ply Sheet:
One or more plies of GAFGLAS' Ply 4, Tri-Ply' Ply 4 Ply Sheet, GAFGLAS'
(Optional)
F1exPly` 6 or GAFGLAS® #80 Ultima'' Base Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane:
One or more plies of Ruberoid' Torch Smooth, Tri-Ply' APP Smooth Membrane,
Ruberoid' Torch Granule, Tri-Ply' APP Granule Cap Sheet, Ruberoid' Torch Plus
Granule FR, Ruberoid' EnergyCap' Torch Plus Granule FR or Ruberoid'
EnergyCap'' Torch Granule FR torch applied according to manufacturer's application
instructions.
Or
One or more plies of Ruberoid' HW 25 Smooth, Ruberoid' HW Smooth, Ruberoid'
HW Granule, Ruberoid' HW Granule FR, Ruberoid' HW Plus Granule, Ruberoid'
HW Plus Granule FR or Ruberoid' EnergyCap' HW Plus Granule FR applied
according to manufacturer's application instructions.
Surfacing:
Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied in accordance with manufacturer's
instructions. Any coating listed below used as a surfacing must be listed with a
current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
Approved asphalt at 60 lbs./sq.
2.
GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or
GAFGLAS' EnergyCap"' Mineral -Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3.
TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings'' Roof Mate MB Plus Coating applied at a
minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT'
Membrane or United Coatings' Roof Mate TCM Coating applied in one or more coats
at a minimum rate of 1.0 gal./sq. per coat.
4.
A fibered aluminum coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -82.5 psf. (See General Limitation #7)
NOA No.: 18-0919.11
MIAMMAD6 COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 14 of 16
Membrane: SBS/SBS Cold Applied
Deck Type 5: Cementitious Wood Fiber, Non -Insulated
Deck Description: Cementitious wood fiber
System Type E(2): Anchor sheet mechanically fastened
All General and System Limitations shall apply.
Anchor Sheet: Install one ply of GAFGLAS® 475 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS®
#80 Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet,
Ruberoid® HW 25 Smooth, Ruberoid® HW Smooth, Ruberoid® 20 Smooth or Ruberoid®
Mop Smooth mechanically fastened with 1.8" Drill- Tec' Locking Impact Nail fastened
at 9" o.c. at the 3" side lap and in two 12" o.c. staggered rows in the field.
Ply Sheet:
One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® FlexPly"
(Optional)
6, GAFGLAS® #80 Ultima' Base Sheet, Ruberoid® 20 Smooth Ruberoid® Mop Smooth,
Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane:
One or more plies of Ruberoid® 30 Granule, Ruberoid® 30 Granule FR, Ruberoid® 30
Plus Granule FR, Ruberoid® Mop Granule, Tri-Ply® SBS Granule Cap
Sheet, Intec Flex
PRF, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid®
Mop Plus Smooth,
Ruberoid® Mop Plus Granule, Ruberoid® Mop Plus Granule FR, Ruberoid® EnergyCap'"
Mop Plus Granule FR, Ruberoid® Mop Granule FR or Ruberoid® EnergyCap' 30
Granule FR adhered in a full mopping of approved asphalt applied within the EVT range
and at a rate of 20-40 lbs./sq. or in MatrixT"' 102 SBS Membrane Adhesive at an
application rate of 1-2 gal./sq.
Surfacing:
Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied in accordance with manufacturer's
instructions. Any coating listed below used as a surfacing must be listed with a
current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
Approved asphalt at 60 lbs./sq.
2.
GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLAS® EnergyCap'" Mineral -Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3.
TOPCOAT® Surface Seal SB or United Coatings" Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings'' Roof Mate MB Plus Coating applied at a
minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT' Membrane
or United Coatings' Roof Mate TCM Coating applied in one or more coats at a
minimum rate of 1.0 gal./sq. per coat.
4.
A fibered aluminum coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -82.5 psf. (See General Limitation #7)
NOA No.: 18-0919.11
MianiHE 6 couNTv Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 15 of 16