Loading...
HomeMy WebLinkAboutNOAMIAM12M Em -- DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) nf) w4w.miamidade.eov/econom en a 1 Campus Drive DEC 0 5 Z018 SCANNED Parsippany, NJ 07054 BY ST. Lucie County, Permltting St. Lucie Coun4g/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). r This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke; modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid®Modified Bitumen Roof System for Cementitious Wood Fiber Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 15-1020.05 and consists of pages 1 through 16. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI•DADE COUNTY EI4 1 File Copy NOA No.: 18-0919.11 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 1 of 16 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Cementitious Wood Fiber Maximum Design Pressure: -82.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description GAFGLAS® Ply 4 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet (1 meter) Wide reinforced with fiberglass mat. Tri-Ply® ply 4 Ply Sheet 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet (1 meter) Wide reinforced with a fiberglass mat. GAFGLAS® 39.37'.' ASTM D2178 Smooth surfaced asphaltic ply sheet F1exPly"" 6 (1 meter) Wide reinforced with fiberglass mat. GAFGLAS® #75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet (1 meter) Wide reinforced with fiberglass mat. Tri-Ply® #75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet (1 meter) Wide reinforced with a fiberglass mat. GAFGLAS® #80 Ultima"" 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet Base Sheet (1 meter) Wide reinforced with fiberglass mat. GAFGLAS® Stratavent® 39.37" ASTM D4897 Smooth surfaced asphaltic perforated Perforated Venting Base (1 meter) Wide venting base sheet reinforced with Sheet fiberglass mat. GAFGLAS® Stratavent® 39.37" ASTM D4897 Smooth surfaced asphaltic nailable venting Nailable Venting Base Sheet (1 meter) Wide base sheet reinforced with fiberglass mat. Bottom side surfaced with granules. Ruberoid® HW 25 Smooth 39.37" ASTM D6163 Smooth surfaced torch applied SBS base (1 meter) Wide or ply sheet reinforced with a fiberglass mat. Ruberoid®HW Smooth 39.37" ASTM D6164 Smooth surfaced torch applied SBS base or (1 meter) Wide ply sheet reinforced with a polyester mat. Ruberoid® HW Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® HW Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced heat -welded (1 meter) Wide SBS cap sheet reinforced with a polyester mat. Ruberoid® HW Plus Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® HW Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced torch FR (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. Ruberoid® EnergyCap" HW 39.37" ASTM D6164 Fire retardant granule surfaced heat -welded Plus Granule FR (1 meter) Wide SBS cap sheet reinforced with a polyester mat. Cap sheet is factory coated with EnergyCote'. NOA No.: 18-0919.11 MIAMI-DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 2 of 16 Test Product Product Dimensions Specification Description Ruberoid® Torch Smooth 39.37" ASTM D6222 Smooth surfaced torch applied APP base or (1 meter) Wide ply sheet reinforced with a polyester mat. Tri-Ply® APP Smooth 39.37" ASTM D6222 Smooth surfaced torch applied APP cap, Membrane (1 meter) Wide base or ply sheet reinforced with a polyester mat. Ruberoid® Torch Granule 39.37" ASTM D6222 Granule surfaced torch applied APP cap (1 meter) Wide sheet reinforced with a polyester mat. Tri-Ply® APP Granule Cap 39.37" ASTM D6222 Granule surfaced torch applied APP cap Sheet (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® Torch Plus 39.37" ASTM D6222 Fire retardant granule surfaced torch Granule FR (1 meter) Wide applied APP cap sheet reinforced with a ' polyester mat. Ruberoid® EnergyCap 39.37" ASTM D6222 Fire retardant granule surfaced torch Torch Plus Granule FR (1 meter) Wide applied APP cap sheet reinforced with a polyester mat. Cap sheet is factory coated with EnergyCote'. Ruberoid® EnergyCap"' 39.37" ASTM D6222 Fire retardant granule surfaced torch Torch Granule FR (1 meter) Wide applied APP cap sheet reinforced with a polyester mat. Cap sheet is factory coated with EnergyCote'. Ruberoid® 20 Smooth 39.37" ASTM D6163 SBS polymer -modified asphalt base or ply 1 (1 meter) Wide sheet reinforced with a fiberglass mat. Ruberoid® 30 Granule 39.37" ASTM D6163 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a fiberglass mat. Ruberoid® 30 Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop applied (1 meter) Wide SBS cap sheet reinforced with fiberglass mat. Ruberoid® 30 Plus Granule 39.37" ASTM D6163 Fire retardant granule surfaced mop applied FR (1 meter) Wide SBS cap sheet reinforced with fiberglass mat. Ruberoid® Mop Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Tri-Ply® SBS Granule Cap 39.37" ASTM D6164 Granule surfaced mop applied SBS cap Sheet (1 meter) Wide sheet reinforced with a polyester mat. Intec Flex PRF 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® Mop Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base or (1 meter) Wide ply sheet reinforced with a polyester mat. Ruberoid® Mop Smooth 1.5 39.37" ASTM D6164 Smooth surfaced mop applied SBS base or (1 meter) Wide ply sheet reinforced with a polyester mat. Ruberoid® Mop Plus Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base or (1 meter) Wide ply sheet reinforced with a polyester mat. Ruberoid® Mop Plus Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® Mop Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced mop applied FR (1 meter) Wide SBS cap sheet reinforced with a polyester mat. NOA No.: 18-0919.11 niarnr_9 8 ouNrr Expiration Date: 11/06/23 Approval Date: 11/O1/18 Page 3 of 16 Test Product Product Dimensions Specification Description Ruberoid;l EnergyCap' Mop 39.37" ASTM D6164 Fire retardant granule surfaced mop applied Plus Gratiule FR (1 meter) Wide SBS cap sheet reinforced with a polyester mat. Cap sheet is factory coated with EnergyCote'. Ruberoid® Mop Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced mop applied (1 meter) Wide SBS cap sheet reinforced with a polyester mat. Ruberoid" EnergyCap'" 30 39.37" ASTM D6163 Fire retardant granule surfaced mop applied Granule FR (1 meter) Wide SBS cap sheet reinforced with a fiberglass mat. Cap sheet is factory coated with EnergyCote'. GAFGLAS® Mineral- 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Surfac4Cap Sheet (1 meter) Wide reinforced with fiberglass mat. Tri-Ply® BUR Granule Cap 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Sheet (1 meter) wide reinforced with a fiberglass mat. GAFGLAS® EnergyCap'' 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Mineral -Surfaced Cap Sheet (1 meter) Wide reinforced with fiberglass mat. Cap sheet is factory coated with EnergyCote'". Matrix''1102 SBS Membrane 3, 5 or ASTM D3019 Fiber reinforced rubberized cold -applied Adhesive 55 gallons adhesive for modified bitumen roof systems. Matrix '"'307 Premium 3, 5 or ASTM D41 Asphalt concrete primer used to promote Asphalt Primer 55 gallons adhesion of all types of asphalt -based roofing materials. TOPCOArMembrane 1, 5 or ASTM D6083 Water -based elastomeric coating 55 gallons United Coatings' Roof Mate 1, 5 or ASTM D6083 Water -based elastomeric coating TCM Coating 55 gallons TOPCOAT® 5 or 55 gallons ASTM D6083 Solvent -based thermoplastic rubber sealant Surface Seal SB designed to protect and restore aged roof surfaces and to increase roof reflectivity. United Coatings" Surface 5 or 55 gallons ASTM D6083 Solvent -based thermoplastic rubber sealant Seal SB Roof Coating designed to protect and restore aged roof surfaces and to increase roof reflectivity. TOPCOAT® MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer designed to block asphalt bleed -through. United Coatings' Roof Mate 5 or 55 gallons Proprietary Water based, low VOC primer designed to MB Plus Coating block asphalt bleed -through. FlexSeal" Sealant 1 gallon, TAS 139 Solvent -based elastomeric sealant. 5 gallons or 1 qt. tube NOA No.: 18-0919.11 MIAMI•DAD' COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 4 of 16 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuard' Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard'' Tapered Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard' Ultra Polyiso Insulation Glass -faced polyisocyanurate GAF foam insulation. EnergyGuard' RA Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard' RA Tapered Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard' RH Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard' RH Tapered Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyG,bard" RN Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard' RN Tapered Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard' Perlite Roof Insulation Perlite insulation board. GAF EnergyGuard' Perlite Recover Board Perlite recover board GAF SECUROCK" Gypsum -Fiber Roof Board Gypsum board United States Gypsum Corp. Structodek" High Density Fiber Board Roof High density fiberboard Blue Ridge Fiberboard, Inc. Insulation DensDeck" Roof Board Gypsum board Georgia-Pacific Gypsum LLC DensDeck" Prime Roof Board Gypsum board Georgia-Pacific Gypsum LLC APPROVED FASTENERS: Fastener Product Number Name 1 Drill -Tee'" Locking Impact Nail TABLE 3 Product Description Dimensions Preassembled fastener/plate Fastener: unit for base ply and Various insulation attachment to lengths cementitious wood fiber, Plate: 2.7" poured gypsum and diameter lightweight insulating concrete decks. Manufacturer (With Current NOA) GAF NOA No.: 18-0919.11 MIAMI•DAD; COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 5 of 16 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMINOA No.: 18-0919.11 M, 9 COUNTY . •. •, , Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 16 of 16 EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date FM Approvals FM 4470 3014547 05/22/03 FM 4470 3040738 05/18/12 FM 4470 3042887 11/14/11 FM 4470 3044688 03/01/12 FM 4470 3048066 12/13/13 FM 4470 3031294 06/21/11 FM 4470 ODOA8.AM 07/09/97 FM 4470 OY9Q5.AM 04/01/98 FM 4470 2B8A4.AM 07/02/97 FM 4470 3B9Q1.AM 01/08/98 FM 4470 OT4ALAM 12/14/05 FM 4470 FM 797-10228-267 01/15/15 FM 4470 RR203450 12/04/15 FM 4470 FM Letter 04/11/13 FM 4470 FM Letter 09/15/15 Exterior Research & Design, LLC TAS 117 4670.03.01-1 09/20/01 Trinity I ERD ASTM D6163 G6850.08.08 08/01/08 ASTM D6164 G6850.08.08-RI 04/14/11 ASTM D6222 G6850.10.08 10/06/08 ASTM D6222 G6850.11.08 02/17/09 ASTM D6222 G30250.02.10-2 02/11/10 ASTM D3909 G30250.02.10-3-R2 06/03/15 ASTM D6164 G31360.03.10 03/31/10 ASTM D6164 G33470.01.11 01/13/11 ASTM D6163 G34140.04.11-2 04/25/11 ASTM D4601 G34140.04.11-4-R2 06/04/15 ASTMD4879 G34140.04.11-5-R3 06/04/15 ASTM D6222 G40620.07.12-2 07/17/12 ASTM D6163 G40630.01.14-1 01/06/14 ASTM D6164 G40630.01.14-2A 01/07/14 ASTM D6164 G40630.01.14-2A-1-Rl 04/10/14 ASTM D6164 G40630.01.14-2B-Rl 01/16/15 ASTM D6164 G40630.01.14-2C 01/07/14 ASTM D6164 G40630.03.14 03/06/14 ASTM D6222 G43190.03.14-1 03/06/14 ASTM D6222 G43190.03.14-2 03/06/14 ASTM D6222 G43190.05.14-R1 05/20/14 ASTM D6222 G43190.11.13-1 11/15/13 ASTM D3909 G43610.01.14 01/22/14 ASTM D6163 G46160.02.15 02/1'2/15 ASTM D6163 G46160.02.15-2D-1 02/09/16 ASTM D6163 G46160.03.15 03/1-1/15 ASTM D6163 G46160.09.14-2A 09/09/14 ASTM D6164 G46160.09.14-3A 09/09/14 ASTM D6164 G46160.09.14-313 09/09/14 NOA No.: 18-0919.11 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 6 of 16 EVIDENCE SUBMITTED: (CONTINUED Test Agency Name Report Date Trinity I ERD ASTM D6164 G46160.09.14-3C 09/09/14 ASTM D6164 G46160.12.14-3E 12/29/14 ASTM D3909 SC6870.08.14-R1 09/04/14 ASTM D2178 SC9700.08.15-R1 08/23/11 ASTMD6163 SC10680.05.16 05/10/16 ASTM D6164 SC13105.03.17-R1 03/23/17 ULLLC UL790 R1306 08/21/18 PRI Construction Materials TAS 139 GAF-122-02-01 05/07/06 Technologies LLC. ASTM D2178 GAF-314-02-01 08/23/11 ASTM D2178 GAF-315-02-01 08/23/11 ASTM C1289 GAF-369-02-01 10/22/12 ASTM C1289 GAF 417-02-01 05/28/13 ASTM C1289 GAF-464-02-01 02/06/14 ASTM D6083 GAF-498-02-01 09/16/16 ASTM D6083 GAF-499-02-01 03/12/14 ASTM D6083 GAF-500-02-01 03/12/14 ASTM C1289 GAF-629-02-01 03/01/16 TAS 139 GAF-671-02-01 07/01/16 ASTM D6083 GAF-692-02-01 03/14/16 IRT-ARGON, Inc. TAS 114 02-026 07/26/02 NOA No.: 18-0919.11 MIAMIDAD; COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 7 of 16 i APPROVED ASSEMBLIES Membrane Type: SBS Heat Weld Deck Type 5I: Cementitious Wood Fiber, Insulated Deck Description: Cementitious Wood Fiber System Type A(1): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. Anchor Sheet: One ply of GAFGLAS' #75 Base Sheet, Tri-Ply' #75 Base Sheet, GAFGLAS' #80 Ultima'' Base Sheet, GAFGLAS® Stratavent' Nailable Venting Base Sheet, Ruberoid® HW 25 Smooth, Ruberoid' HW Smooth, Ruberoid® 20 Smooth or Ruberoid' Mop Smooth mechanically fastened with Drill-Tec' Locking Impact Nail at a 3" side lap 9" o.c. and in two rows staggered in the center of the sheet 12" o.c. All General and System Limitations shall apply. One or more layers of any of the following insulations. (Optional) Base Layer Insulation Fasteners Fastener (Table 3) Density/fe EnergyGuard" Polyiso Insulation, EnergyGuard'' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck' Roof Board, SECUROCK' Gypsum -Fiber Roof Board Minimum 1/4" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. GAF requires either a ply of GAFGLAS' Stratavent' Perforated Venting Base Sheet laid dry or a layer of EnergyGuard'" Perlite Roof Insulation or wood fiber overlay board on polyisocyanurate insulation applicailions. Base Sheet: One or more plies of Ruberoid' HW 25 Smooth or Ruberoid' HW Smooth adhered to the insulation in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation #4) Membrane: One or more plies of Ruberoid' HW 25 Smooth, Ruberoid' HW Smooth, Ruberoid' HW Granule, Ruberoid' HW Granule FR, Ruberoid' HW Plus Granule, Ruberoid' HW Plus Granule FR or Ruberoid' EnergyCapn' HW Plus Granule FR applied according to manufacturer's instructions. NOA No.: 18-0919.11 Mia,rn-nnoe COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 8 of 16 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied in accordance with manufacturer's instructions. Any coating listed below used as a surfacing must be listed with a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap'' Mineral -Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT' Surface Seal SB or United Coatings" Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT' MB Plus or United Coatings" Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT" Membrane or United Coatings'" Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. A fibered aluminum coating applied in accordance with manufacturer's application instructions. Maximum Design Pressure: -82.5 psf. (See General Limitation #7) NOA No.: 18-0919.11 MIAMI-DAD, COUNTY Expiration Date: 11/06/23 FUMApproval Date: 11/01/18 Page 9 of 16 Membrane Type: APP/SBS Heat Weld Deck Type 5I: Cementitious Wood Fiber, Insulated Deck Description: Cementitious Wood Fiber System Type A(2): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. Anchor Sheet: One ply of GAFGLAS' #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet,, Ruberoid' HW 25 Smooth, Ruberoid® HW Smooth, Ruberoid® 20 Smooth, Ruberoid® Mop Smooth mechanically fastened with Drill-Tec''I Locking Impact Nail at a 3" side lap 9" o.c. and in two rows staggered in the center of the sheet 12" o.c. One or more layers of any of the following insulations Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard' Polyiso Insulation, EnergyGuard"" Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation EnergyGuard"' RA Polyiso Insulation, EnergyGuard'T' RN Polyiso Insulation Minimum 1.3" thick N/A N/A Structodek® High Density Fiber Board Roof Insulation, EnergyGuard' Perlite Recover Board, EnergyGuard" Perlite Roof Insulation Minimum %" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. GAF requires either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuard"' Perlite Roof Insulation or wood fiber overlay board on polyisocyanurate insulation applications. Base Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® FlexPly"" 6, GAFGLAS® #75 Base Sheet, Tri-Ply® 475 Base Sheet, GAFGLAS® #80 Ultima'° Base Sheet, Ruberoid® 20 Smooth, Ruberoid' Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid' Mop Plus Smooth adhered to the insulation in a full mopping of an approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation #4) Or GAFGLAS' Stratavent' Perforated Venting Base Sheet loose laid dry followed by a mopped ply sheet listed below. Ply Sheet: (Required over GAFGLAS' Stratavent' Perforated Venting Base Sheet) One or (Optional) more plies of GAFGLAS' Ply 4, Tri-Ply' Ply 4 Ply Sheet, GAFGLAS' FlexPly' 6, GAFGLAS' 480 Ultima"° Base Sheet or Ruberoid' 20 Smooth adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 18-0919.11 MiAMMADe COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 10 of 16 Membrane: One or more plies of Ruberoid® Torch Smooth, Tri-Ply® APP Smooth Membrane, Ruberoid' Torch Granule, Tri-Ply® APP Granule Cap Sheet, Ruberoid' Torch Plus Granule FR, Ruberoid' EnergyCap" Torch Plus Granule FR or Ruberoid' EnergyCap' Torch Granule FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid' HW 25 Smooth, Ruberoid' HW Smooth, Ruberoid' HW Granule, Ruberoid' HW Granule FR, Ruberoid' HW Plus Granule, Ruberoid' HW Plus Granule FR or Ruberoid' EnergyCap"' HW Plus Granule FR applied according to manufacturer's application instructions. Or (Only for use over Ruberoid' 20 Smooth Ply Sheet) GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral - Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied in accordance with manufacturer's instructions. Any coating listed below used as a surfacing must be listed with a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT' Membrane or United Coatings" Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. A fibered aluminum coating applied in accordance with manufacturer's application instructions. Maximum Design Pressure: -82.5 psf. (See General Limitation #7) MIAMI•DADE COUNTY NOA No.: 18-0919.11 ..., , Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 11 of 16 Membrane Type: SBS/SBS Cold Applied Deck Type 5I: Cementitious Wood Fiber, Insulated Deck Description: Cementitious Wood Fiber System Type A(3): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. Anchor Sheet: One ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet, Ruberoid® HW 25 Smooth, Ruberoid® HW Smooth, Ruberoid® 20 Smooth, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth mechanically fastened with Drill-Tec' Locking Impact Nail at a 3" side lap 9" o.c. and in two rows staggered in the center of the sheet 12" o.c. All General and System Limitations shall apply. One or more layers of any of the following insulations Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard' Polyiso Insulation, EnergyGuard'" Ultra Polyiso Insulation, EnergyGuard'' RH Polyiso Insulation, EnergyGuard'' RA Polyiso Insulation Minimum 1.3" thick N/A N/A EnergyGuard' Polyiso Insulation, EnergyGuard'"' Ultra Polyiso Insulation, EnergyGuard'" RH Polyiso Insulation, EnergyGuard' RN Polyiso Insulation Minimum 1.4" thick N/A N/A Structodek® High Density Fiberboard Roof Insulation, EnergyGuard'' Perlite Recover Board, EnergyGuard" Perlite Roof Board Minimum''V2" thick N/A N/A Base or Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck® Roof Board, DensDeck® Prime® Roof Board, SECUROCK® Gypsum -Fiber Roof Board Minimum''/e" thick N/A N/A Structodek® High Density Fiberboard Roof Insulation, EnergyGuard' Perlite Recover Board, EnergyGuard" Perlite Roof Board Minimum%" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. GAF requires either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuard' Perlite Roof Insulation or wood fiber overlay board on polyisocyanurate insulation applications. Base Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® FlexPly 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80 Ultima' Base Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth adhered to the insulation in a full mopping of an approved asphalt applied within the EVT range and at a rate of 20-40 lbs. sq. (See General Limitation 44) NOA No.: 18-0919.11 MIAMIHE 0 COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 12 of 16 Base Sheet: Or (Continued) GAFGLAS' Stratavent' Perforated Venting Base Sheet loose laid dry followed by a mopped ply sheet listed below. Ply Sheet: (Required over GAFGLAS® Stratavent® Perforated Venting Base Sheet) One or (Optional) more plies of GAFGLAS' Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS' FlexPly' 6, GAFGLAS' #80 Ultima'" Base Sheet, Ruberoid' 20 Smooth, Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid' Mop Plus Smooth adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid' 30 Granule, Ruberoid' 30 Granule FR, Ruberoid' 30 Plus Granule FR, Ruberoid' Mop Granule, Tri-Ply' SBS Granule Cap Sheet, Intee Flex PRF, Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid' Mop Plus Smooth, Ruberoid' Mop Plus Granule, Ruberoid' Mop Plus Granule FR, Ruberoid' EnergyCap' Mop Plus Granule FR, Ruberoid' Mop Granule FR or Ruberoid' EnergyCap' 30 Granule FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in MatrixTp° 102 SBS Membrane Adhesive at an application rate of 1-2 gal./sq. Or (Only for use over Ruberoid' 20 Smooth, Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5 or Ruberoid' Mop Plus Smooth) GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied in accordance with manufacturer's instructions. Any coating listed below used as a surfacing must be listed with a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT' Surface Seal SB or United Coatings'"' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT' Membrane or United Coatings" Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. A fibered aluminum coating applied in accordance with manufacturer's application instructions. Maximum Design Pressure: -82.5 psf.(See General Limitation #7) MIAMI•DADE COUNTY [...I 1 NOA No.: 18-0919.11 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 13 of 16 Membrane Type: APP/SBS Heat Weld Deck Type 5: Cementitious Wood Fiber, Non -Insulated Deck Description: Cementitious Wood Fiber System Type E(1): Anchor sheet mechanically fastened All General and System Limitations shall apply. Anchor Sheet: Install one ply of GAFGLAS' 975 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS' #80 Ultima'°' Base Sheet, GAFGLAS® Stratavent' Nailable Venting Base Sheet, Ruberoid' HW 25 Smooth, Ruberoid® HW Smooth, Ruberoid' 20 Smooth or Ruberoid' Mop Smooth mechanically fastened with 1.8" Drill -Tee' Locking Impact Nail fastened at 9" o.c. at the 3" side lap and in two 12" o.c. staggered rows in the field. Ply Sheet: One or more plies of GAFGLAS' Ply 4, Tri-Ply' Ply 4 Ply Sheet, GAFGLAS' (Optional) F1exPly` 6 or GAFGLAS® #80 Ultima'' Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid' Torch Smooth, Tri-Ply' APP Smooth Membrane, Ruberoid' Torch Granule, Tri-Ply' APP Granule Cap Sheet, Ruberoid' Torch Plus Granule FR, Ruberoid' EnergyCap' Torch Plus Granule FR or Ruberoid' EnergyCap'' Torch Granule FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid' HW 25 Smooth, Ruberoid' HW Smooth, Ruberoid' HW Granule, Ruberoid' HW Granule FR, Ruberoid' HW Plus Granule, Ruberoid' HW Plus Granule FR or Ruberoid' EnergyCap' HW Plus Granule FR applied according to manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied in accordance with manufacturer's instructions. Any coating listed below used as a surfacing must be listed with a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap"' Mineral -Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT' MB Plus or United Coatings'' Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. A fibered aluminum coating applied in accordance with manufacturer's application instructions. Maximum Design Pressure: -82.5 psf. (See General Limitation #7) NOA No.: 18-0919.11 MIAMMAD6 COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 14 of 16 Membrane: SBS/SBS Cold Applied Deck Type 5: Cementitious Wood Fiber, Non -Insulated Deck Description: Cementitious wood fiber System Type E(2): Anchor sheet mechanically fastened All General and System Limitations shall apply. Anchor Sheet: Install one ply of GAFGLAS® 475 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet, Ruberoid® HW 25 Smooth, Ruberoid® HW Smooth, Ruberoid® 20 Smooth or Ruberoid® Mop Smooth mechanically fastened with 1.8" Drill- Tec' Locking Impact Nail fastened at 9" o.c. at the 3" side lap and in two 12" o.c. staggered rows in the field. Ply Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® FlexPly" (Optional) 6, GAFGLAS® #80 Ultima' Base Sheet, Ruberoid® 20 Smooth Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid® 30 Granule, Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid® Mop Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth, Ruberoid® Mop Plus Granule, Ruberoid® Mop Plus Granule FR, Ruberoid® EnergyCap'" Mop Plus Granule FR, Ruberoid® Mop Granule FR or Ruberoid® EnergyCap' 30 Granule FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or in MatrixT"' 102 SBS Membrane Adhesive at an application rate of 1-2 gal./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied in accordance with manufacturer's instructions. Any coating listed below used as a surfacing must be listed with a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap'" Mineral -Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United Coatings" Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT® MB Plus or United Coatings'' Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. A fibered aluminum coating applied in accordance with manufacturer's application instructions. Maximum Design Pressure: -82.5 psf. (See General Limitation #7) NOA No.: 18-0919.11 MianiHE 6 couNTv Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 15 of 16