HomeMy WebLinkAboutTRUSS PLANI --------------------- SEE FLOOR/ROOF PLAN FOR CONNECTOR TYPE I I�--------------- I I -- A - A WALL SECTION SCALE: NTS 5LA5 FOOTING 2 x 6 S.Y.P, * 2'O" O/C 5/8" COX PLY W/GAF RUBEROID MOD. BITUMEM ROOFING PER N.O.A. SEE FLOOR/ROOF PLAN NO. 18-OSIS.12 —i F FOR CONNECTOR TYPE VIM VICI WALL C=IWNU EXISTING DOUBLE 2 x4 TOP PLATE 2 x ro SUB -FACIA -ZE I x6FACIA W/ 1 x2 PT DRIP EDGE W/2 x 2 FLASHING JAMES HARDIE SOFFIT PER N.O.A. NO, I1-0821.21 2 x 4 FARING WALL R WALL 4 P.T. TING GENERAL CONSTRUCTION NOTES: 1. ALL CONSTRUCTION MUST CONFORM TO FLORIDA BUILDING CODE 2017, 6th Edition 2. METAL STRAPS, CLIPS AND HARDWARE SHALL BE GALVANIZED, OR APPROVED EQUAL. 3. STRUCTURAL WOOD CRITERIA: PRIMARY WOOD FRAMING MEMBERS SHALL BE ND. 2 SOUTHERN PINE OR BETTER, SURFACED DRY, USED AT 19% MAXIMUM M.C. WITH THE FOLLOWING STRESS RATINGS, UNLESS OTHERWISE NOTED: I. FB SINGLE MEMBER 1,200 PSI II. FE REPETITIVE MEMBERS 1,400 PSI III. FC PERPENDICULAR TO GRAIN 565 PSI IV. E 1,600,000 4. ALL WOOD IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED. 5. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 6. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WLL BE ADDRESSED BY THE ENGINEERAS CONSTRUCTION PROGRESSES. 7. SPLITTING OR CRACKING OF STRUCTUAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 8. INTERIOR DRYWALL TO BE SCREWED WITH DRYWALL SCREWS 1.5" LONG AND 0.131 INCHES DIAMETER. 9. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 112" GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8" TYPE GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN 1/2" TYPE "X" GYPSUM BOARD OR EQUIVALENT. (R309.2) 10. CONTRACTOR IS RESPONSIBLE FOR ADEQUATE BRACING OF ALL STRUCTURAL AND NON-STRUCTURAL MEMBERS DURING CONSTRUCTION. PLYWOOD SHEATHING MUST BE APPLIED AS THE ROOF OR FLOOR TRUSSES ARE ERECTED TO PREVENT TOPPLING. REFER TO TPI & WTCA PUBLICATION "BUILDING COMPONENT SAFETY INFORMATION' FOR HANDLING AND BRACINGOF TRUSSES. TEMPORARY BRACING PER HIB-91. 11. CONTRACTOR TO OBTAIN THE LATEST PRODUCTAPROVALS FROM THE MANUFACTURERS, VERIFY SAFE PRESSURES, THE EXPIRATION DATES, INSTALLATION SPECIFICATIONS AND SUITABLILITY OF THE PRODUCT BEFORE INSTALLATION OFALL BUILDING COMPONENTS. 12. ALL DRAWINGS ARE CONSIDERED PRELIMINARY UNTIL THEY HAVE BEEN APPROVED BY THE LOCAL BUILDING DEPARTMENT. DO NOT ORDER ANY WORK OR MATERIAL WITH PRELIMINARY DRAWINGS. 13. CONTRACTOR TO LAYOUT THE WORK, VERIFY ALL DIMENSIONS, ELEVATIONS, PITCH, WALL AND CEILING HEIGHTS PRIOR TO ORDERING ANY WORK OR MATERIAL. 14. WIND LOADS: FBC 2017, 6th EDITION, 170 MPH, 3-SECOND GUST, EXPOSURE C. A NO ELECTRIC WORK ELECTRIC IS EXISTING DO NOT SUBSTITUTE CONNECTORS. DO NOT SHEATH TRUSSES BEFORE ALL STRAPS ARE IN PLACE, TRUSS CONNECTOR SCHEDULE BRNG PLY CONNECTOR QTY CONNECTOR DESIGN FASTENERS FL POINT UPLIFT CODE OREF: A I HIOA I 1010 (8) IOd X 1-I/2" SIMPSON (F2=410) (8) IOdx 1-i/2" 114i3 O I MTS 16 a40 (1) iOdx 101/2" 114i3 SIMPSON (F2=300) (Z) IOd x 1-1/2" I. LATERAL FORCES PERPENDICULAR AND PARALLEL TO WALL HAS BEEN CONSIDERED (LESS THAN 300 PLF.) 2. BUILDER TO APPROVE TEMPORARY BRACING TO PREVENT TOPPLING OF TRUSSES, SEE HIB-S, 3. OTHER SPECS, OIF DIFFERENT FROM ABOVE, HAVE THE PRIORITY. ROOF NAILING: 8d RING SHANK NAILS 6" O/C FIELD, 4" O/C EDGES Design Criteria COMPONENTS AND CLADDING Wind Load Type = FBC 2011 Building Type = Enclosed Occupancy Factor = I Category II, Exposure = C A: Ht > 10', B: Urban, C: Open Terrain W/ Scattered Obstructions, D. Coastal WIND RESISTANCE TC DL 5 PSF BC DL 5 PSF TOTAL 10 PSF Duration= 1.33 WIND m Il0 MPH GRAVITY LOADS OVER 5,0000 ARE SHOWN UPLIFT LOADS OVER 1,0000 ARE SHOWN ON LAYOUT, EXISTING I STORY FRAMED RESIDENCE A RIGHT ELEVATION SCALE : 1/4" = 1'0" SEAR ELEVATION KALE : 1/4" - 1'0" E EXISTING iHTIS ON E WALL AS U ENTER E ROOM F ROOF DESIGNED PER: FBC 201-f ASCE 1-10 TPI - 200-7 STRUCTURAL NOTES - TRUSSES I. ROOF NAILING PATTERNS: 8d RING SHANK NAILS 6" OC FIELD AND 4" O/C EDGES. 2. STRUCTURAL LUMBER: MINIMUM GRADE LUMBER: 2x12 02 HF, 4x4 02 SYP, ALL OTHERS 02 SYP or STUD SPP, PLYWOOD SHEATHING TO BE APA RATED COX STRUCTURAL. ALL LUMBER IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. WOOD FRAMED BEARING WALLS FIRST STUD AT CONCRETE IS TO BE PT AND ATTACHED WITH 3/16" TAPCONS, 1-1/2" EMBED d 12" OC EXCEPT AS SHOWN. 3, TEMPORARY BRACING PER HIB-SI. 4, ALL DRAWINGS ARE PRELIMINARY UNTIL THEY ARE APPROVED BY THE GOVERNING PERMITTING AUTHORITY. 5, CONTRACTOR IS RESPONSIBLE FOR LAYOUT OF WORK, ALL DIMENSIONS, ELEVATIONS, PITCH, AND THE WALL AND CEILING HEIGHTS. b m , rn U O Uj to Q LL h Z) Itt U)M w aiw z CJO LL m00O ZOZw .M ¢ CA 0ZOO 40 M OyQw azz= 6 U ,a��r� N N WO ww0~ i�I N N W coI` U) 'y'►y W °aOw W d LO zo.Z W U)WF X zwmw to Ow6m F- Lo wD oar �r^�51 CC) V ev tttK{Unil,tgq�/ —al Q•y o' O PS..J �'� • W f`. �( O:Z=t h v CID f,lrn.. ��npaQ� •�/ I i �Sf12-D/�3 ST. LCCIE COUNTY EI7T Di"-r ^'^\ RE 'IFI1 ED FOR GQAiPLIANCE,/ G.: LEFT ELEVATION SCALE : 1/4" = 1'0" ;ONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS HEOUIRED 8Y FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO ,AMPLY WITH ALL APPLICABLE CODES. AUT MUST BE KEPT ION WILL BE `NUDE. SCOPE OF WORK : i, REMOVE AND REPLACE EXISTING FLAT ROOF SYSTEM W/2 x S,Y.P. W/PITCH. SEC -GUST WIND SPEED 2011, 6TH edition, existing :IIng Code, Level I Alteration BLDG CAT: VB OCCUPANCY: R-3 EXPOSURE: C INT, PRES. COEF: +/- 0.18 BUILDING: ENCLOSED LEVEL II ALTERATIONS, REQUIRE SMOKE DETECTORS IN OUT OF EACH BEDROOM HARD WIRED W/BATTERY B/U. SCANNEEC) BY St. Lucie County File Copy W M a O LLI O DO W Q' m W W LO UZ (If(�WMN pZ0cor z W j04 J Q(Dwu'v �LuCSCDN Loa�, zLLL too�LO L F Q LIA Q 111 z� 0 D- M llI lX w 0 _W 1 a N to z .. N } IW V/ /LU L . LU z m cri W N �- Q N 4 l� 7 W O z0 .. zo z U WIU� off} O 3 W JOB" IS - SHEET 01 SCALE: 1/4" - I'01I