ELECTRICAL LAYOUT PLAN N
SCALE: 1/4" = l'-0" IN
ded 150
3
2 IN MIN SIZE CONDUIT
1/0 CU UNDERGROUND
3 CU NEUTRAL (MIN)
s
GROUNDING ELECTRODE SHALL
COMPLY W/ NEC 250-66.122
CONDUCTOR TO BE #4 COPPER
5/8" X 10' CU. CLAD GROUND (ROE
GROUND TO WATER PIPE & BUILDING STEEL
SCOPE OF WORK
1. REMOVE ALL EXISTING ELECTRICAL WIRING.
2. ADD NEW ELECTRICAL WIRING PER PLAN.
�'W R*kok
2" NIPPLE, (2) #4/0 CU THHN
AWG FEEDER CONDUCTOR
(1) #2/0 CU AWG NEUTRAL (MIN)
MAIN PANEL
277/480V
i
150A
ELECTRICAL RISER
AREA CALCULATIONS
EXISTING BUILDING 1,448 SF
TOTAL AREA 1,448 SF
ELECTRICAL LEGEND
��o
COUNG MOUNTED LIGHT,�/n
C98C
CEILING FAN WITH LIGHT
WALL SCONCE
&
EXHAUST FAN/LIGHT COMBO
110 V. WALL RECEPTACLE
220V ®•
220 V. WALL RECEPTACLE
GFCI�
GROUND FAULT CURRENT
INTERCEPTOR WALL RECEPTACLE
WP@
WEATHER PROOF/GFCI
WALL RECEPTACLE
9W2
MULTI LIGHT BAR
$
LIGHT SWITCH
®
COMBO SMOKE/CARBON
MONOXIDE DETECTOR
4
EXHAUST FAN/LIGHT COMBO
�
ELEC
ELECTRICAL PANEL
PNL
U
ELECTRICAL METER
STITUCTURAL-GENERAIL NOTES; W
f'
GENERAL REQUIREMENTS G
1. THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE'FLORIDA BUILDING CODE
(FBC)",SIXTH EDITION, HEREAFTER REFERRED TO AS THE FBC, AS ADOPTED AND MODIFIED BY THE
AUTHORITYHAVING JURISDICTION (AHJ).
2. WHERE OTHER STANDARDS ARE NOTED IN THE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD
UNLESS A SPECIFIC DATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION INA CODE DOES NOT H
RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE STANDARD. Z
3. THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION AND ALL JOB 0
RELATED SAFETY STANDARDS SUCH AS OSHA AND DOSH (DEPARTMENT OF OCCUPATIONAL SAFETY H
AND HEALTH).
4. THE STRUCTURAL DRAWINGS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND EXTENT OF THE W
PROJECT AND ARE NOT INTENDED TO SHOW ALL DETAILS OF THE WORK ARCHITECTURAL DRAWINGS w
SHALL GOVERN THE WORK FOR ALL DIMENSIONS.
5. PLAN AND DETAIL NOTES AND SPECIFIC LOADING DATA PROVIDED ON INDIVIDUAL PLANS AND DETAIL
DRAWINGS SUPPLEMENTS INFORMATION IN THE STRUCTURAL GENERAL NOTES.
6. ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE AND FORM FOR SPECIFIED ITEMS MAYBE Q N mkt Cn Co h
SUBMITTED WITH ADEQUATE TECHNICAL DOCUMENTATION TO THE ARCHITECT/ENGINEER FOR REVIEW.
ALTERNATE MATERIALS THAT ARE SUBMITTED WITHOUT ADEQUATE TECHNICAL DOCUMENTATION OR 00 THAT SIGNIFICANTLYDEVIATE FROM THE DESIGN INTENT OF MATERIALS SPECIFIED MAYBE RETURNED r- Lu
0
WITHOUT REVIEW. ALTERNATES THAT REQUIRE SUBSTANTIAL EFFORT TO REVIEW WILL NOT BE N N F-
REVIEWED UNLESS AUTHORIZED BY THE OWNER, 00 00 LU p Z
7. ALL STANDARD NOTES AND DETAILS CONTAINED HEREINARE TYPICAL UNLESS NOTED OTHERWISE Q Z co
CONTRACTORS COORD/NAT/ON 00 `1 `1 > j U)
1. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND ACCURACY OF THE WORK WITH r o
ENGINEER AND OTHER TRADES; FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND
DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OFASSEMBLY,AND FOR
PERFORMING WORK INA SAFEAND SECURE MANNER. p
2. DISCREPANCIES, OMISSIONS, OR INCONSISTENCIES WITH APPLICABLE CODE REQUIREMENTS SHALL BE W
BROUGHT TO THEATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK. W W y
3. THE CONTRACTOR SHALL VERIFYALL DIMENSIONS AND CONDITIONS AT THE SITE. CONFLICTS BETWEEN14
W
THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE O W qR Q LLI 4 U
ENGINEER BEFORE PROCEEDING WITH THE WORK. > O O U O y
STRUCTURAL CERTIFICATION
1. 1 CERTIFY THAT THE PLANS AND SPECIFICATIONS COMPLY WITH THE STRUCTURAL PORTION OF THE Q o �
FLORIDA BUILDING CODE FIFTH EDITION. t0 to rn
2 IALSO CERTIFY RESISTANCE TOTHATSTRUCTURAL THE WIND LOADS SPECIF�EDTS DEPICTED ON IN SECTION 6091NESEPLANS THE FBC ANDOCHAPTER 3QUTEINATHE W N Cy)N v
FBC-RESIDENTIAL. W Pi 0) r N
GENERAL REMODEL NOTES -I m
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH FBC FIFTH EDITION "EXISTING BUILDINGS; ITS W 0) OD x x
AMENDMENTS AND ALL GOVERNING LOCAL CODE AND ORDINANCES. _0 N a a
2. PROVIDE ALL REQUIRED MATERIALS FORA COMPLETE INSTALLATION CONSISTENT WITH THE INTENT = 2 Lf) h
OF THESE DOCUMENTS. 0 ^ ^ u- U_
3. MATERIALS ALREADY IN USE MAY REMAIN UNLESS DETERMINED TO BE DANGEROUS TO LIFE, N W ~ z 0
HEALTH OR SAFETY; IN THIS CASE THEY SHALL BE MITIGATED OR MADE SAFE.
4. SUPPLEMENTAL MATERIALS AND MANUFACTURED PRODUCTS THAT ARE NECESSARY TO COMPLY m IN-m a
WITH THE INTENT OF THE DRAWINGS, BUT ARE NOT NOTED OR SPECIFIED ARE TO BE INCLUDED. N O '
5. ALL ASSEMBLY, PRODUCTS, SYSTEMS, ETC. TO BE INSTALLED IN STRICT ACCORDANCE WITH THEIR _ X W
RESPECTIVE MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. CO 0- LL LU
6. OWNER SHALL FAMILIARIZE HIMSELF WITH THE WORK AND EXISTING CONDITIONS AND SHALL W
NOTIFY THE ENGINEER OF ANY CONFLICT OR DISCREPANCIES WITHIN THESE DOCUMENTS PRIOR TO
COMMENCING OR CONTINUING WORK.
7. OWNER SHALL USE PROPER PRECAUTIONS TO INSURE THAT EXISTING CONDITIONS ARE NOT
DAMAGED DURING CONSTRUCTION, LE. INCLEMENT WEATHER ETC. V CD
8. THE PLANS AND SPECIFICATIONS ARE NOT INTENDED TO DEPICT EACH AND EVERY DETAIL. AS % w
PARTY IN THE FIELD, THE CONTRACTOR IS IN THE BEST POSITION TO VERIFY THAT ALL CONDITIONS ` a CC\1
ARE COMPLETED AND PROVIDE A WATERTIGHT STRUCTURE. U m
9. THE ENGINEER SHALL, IN NO WAY BE RESPONSIBLE FOR HOW FIELD WORK IS PERFORMED, SAFETY (�]� O Q
IN, ON OR ABOUT THE JOB SITE, OR METHODS OF PERFORMANCE OR TIMELINESS OF PERFORMANCE v Q U
OF WORK. 06
10. OWNER TO OSTAINAPPROVAL FROM ENGINEER AND OWNER FOR USE OF "OR EQUAL"ITEMS. ® Q� Z_
11. ENGINEER IMLLOIVLYWSITTHES17EATTHEREQUESTBYTHEOWNER, BUILDING OFFIC14LORCONTRACTOR N ER
12. REPAIR AND PATCH TO MATCH EXISTING AS REQUIRED UNLESS OTHERWISE NOTED. NEW AND OLD L W
FINISH TO MATCH IN MATERIAL AND TEXTURE UNLESS OTHERWISE NOTED. W g z
13. PROTECT ALL AREAS NOT BEING REMODELED FROM DAMAGE, DUST, WATER ETC. Uj z
ELECTRICAL REMODEL NOTES ` w Q
Z
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH FBC ELECTRICAL CODE, 2011 NEC, NFPA 70 AND o P
ALL LOCAL CODES AND ORDINANCES. V
2. ALL DAMAGED AREAS TO BE REFINISHED TO MATCH NEW WORK. ■ Q U)
3. ELECTRICAL DESIGN IS INTENDED TO BE A COMPLETE AND WORKABLE ELECTRICAL SYSTEM WITH - z p z
ALL MISCELLANEOUS PARTS, WHETHER SHOWN OR NOT, TO BE INCLUDED. ANY DISCREPANCIES OR W 2 U
DRAFTING OMISSIONS MUST BE REPORTED PRIOR TO BIDDING OR THEY SHALL BE CONSIDERED
INCLUDED.
4. ALL ELECTRICAL SYSTEMS TO REMAIN EXCEPT AS NOTED. Z Cl)5. RE-ROUTE OR ADD AS INDICATED ON PLANS. W
6. ALL MATERIALS USED SHALL BE INSTALLED IN ACCORDANCE WITH THE STANDARDS OF THE
MAT EAL,THE
MANUFACTURER'S INSTRUCTIONS OR THE NFPA 70 WHICHEVER IS MORE
RESTRICTIVE. Q 0
7. USE NEW COPPER WIRE ONLY, NO ALUMINUM. Z
8. ALL WIRES CLOSER THAT 11/4" TO THE EDGE OF FRAMING MEMBERS SHALL BE PROTECTED WITH A
STEEL PLATE AT LEAST 1/16" IN THICKNESS. Q
9. IN THE PROCESS OF INSTALLING OR REPAIRING THE SYSTEMS, ANY PART OF THE BUILDING THAT
MUST BE CHANGED OR REPLACED SHALL BE LEFT IN A SAFE STRUCTURAL CONDITION. Q
10. ALL WIRING SHALL BE INSTALLED SO THAT, WHEN COMPLETED, THE SYSTEM WILL BE FREE FROM
SHORT CIRCUITS AND FROM GROUNDS OTHER THAN REQUIRED OR PERMITTED IN NEC ARTICLE 250. J
11. ALL WIRING SHALL BE INSTALLED INA NEAT AND WORKMANLIKE MANNER, J U
1 Z CONDUCTORS SHALL BE INSULATED AND THE MATERIAL SHALL BE OF ALUMINUM, COPPER -CLAD Q
ALUMINUM, OR COPPER UNLESS OTHERWISE SPECIFIED. U
13. WHERE INSTALLED IN RACEWAYS, CONDUCTORS OF SIZE 8 AWG AND LARGER SHALL BE STRANDED.
14. METAL FRAMING MEMBERS SHALL BE BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR
THE CIRCUIT THAT MAY ENERGIZE THE FRAMING AND BE SIZED IN ACCORDANCE WITH THE NEC
TABLE 250.122. V Q
15. PENETRATIONS THRU FIRE RATED ASSEMBLIES SHALL BE PROTECTED IN ACCORDANCE WITH THE W Z
FBC. _I
16. ANY OUTLET ACCESSIBLE TO THE PUBLIC SHALL BE TAMPER RESISTANT OR PROTECTED WITH W
PLASTIC CAPS WHEN NOT IN USE.
Q
O
ABBREVIATIONS Q o
AB-ANCHORBOLT FIG -FOOTING L-
AW-AUIHORITYHAVINGJURISD/CTION HOR/Z -HORIZONTAL
ALT -ALTERNATE IN-INCH/INCHES Z
BOTT -BOTTOM MAS -MASONRY w
CML/-CONCRE7EMASONRYUN/T MAX -MAXIMUM SCANN-
COL -COLUMN MFR -MANUFACTURER BY�_
CONC -CONCRETE MIN -MINIMUM
CONT -CONTINUOUS MISC -MISCELLANEOUS St. Lucie C( UIl (%) Q j
DLA -DIAMETER MPH-M/LESPERHOUR w w
DIM -DIMENSION NTS-NOTTOSCALE
ON -DOWN OC -ON CENTER �O Q
EA -EACH PSF-POUNDSPERSQUAREFOOT . o
ELEV ELEVA7/OAVELEVATOR REV REV/SlOIWEVISED 0 C)
ENGR .ENGINEER SCHED -SCHEDULE LL
EW-MCHWAY TYP -TYPICAL O
EXIST-DrISANG UNO-UNLESSN07FDOTHERW/SE
IXP -EXPANSION VERT -VERTICAL LL U
EXT-aTERIOR W/ -WNH _j w
FBC-FLORIDABUILDING CODE WA) WITHOUT _j Lu
FF-FINISHROOR WWF- WELDED W/REFABR/C
FND -FOUNDATION WWM- WELDED WIRE MESH ! n O
FT {ED FASTENERS DR STTACHMl�TS -STEEL REINFORC/NGBAR(REBAj , 77 C V
ARE THE RESPONSI8IUTY OF THE ��.. 4.� F, p
CONTRACTOR OF RECORD �° ,
g No. 61000
*e * Y
STATE OF
FOOD O VI MI
F�x�P . P.E.#6 000
THESE PLANIS AND ALL PFICPOS:D WORK teNZ-p/ . r111TE: 07-30-2018
ARE ,SUBJECT TO ANY CORRECTICHS §T, LUCIE COUP EiZi.DT` - uNAL $ '
REQUIRED BY FIELD INSPECTORS THAT #Lkj9NVED FORCOMPLIANCG SHEET
P LAY BE NECESSARY IN ORDER TO mvin%D BY
�ATB > •ER�IIT MUr�XEPTI JOB
COP¢ii}LY b"llTli ALL APPLICABLE CODES.:Ly*!\ t�
9pECT10N WILL BE . sl
OF 1
_ 18-0181
PERMIT SET