Loading...
HomeMy WebLinkAboutCARPORT DETAILSr ROLL -UP DOOR FRONT ELEVATION REAR ELEVATION GENERALNOTES FILE COPY RECEIVED =�`:� ¢ o z4 00 F d N Z ; U> •••. Z 0 c N =S DE" 0 6 �DIB. L��d. 'CO �; o .., .� Ui RIGHT SIDE ELEVATION ST. Lucie County, Permitting ///////11111111 1\\\\\1YY U O LEFT SIDE ELEVATION 1. THESE PLANS BELONG EXCLUSIVELY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM(MWFRS), COMPONENTS AND CLADDING(C&C), AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PROPERTY SET -BACKS, ELECTRICAL, PLUMBING, INGRESVEGRESS, FINISH FLOOR SLOPES AND ELEVATIONS, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE LIABILITY OF OTHERS. 2. THESE STRUCTURES ARE ENGINEERED AS NON -HABITABLE STORAGE/UTUTY STRUCTURES (RISK CATEGORY I) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE OWNER'S RISK FLORIDA ENGINEERING LLC, SHALL NOT BE RESPONSIBLE FOR FAILURE OR STRUCTURAL DAMAGE DUE TO THE EXTRA LOAD. 3. ALL C&C SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S MANUALS AND INSTRUCTIONS. 4. FRAMING AROUND ROLL -UP DOOR OPENINGS SHALL BE I2GA TS POSTS AND I2GA TUBE STEEL ITS) H EADERS CROSS-SECTION MATCHING THE REMAINDER OF THE BUILDING FRAMING. & ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL, ALL FASTENERS SHALL BE ZINC COATED HARDWARE. B. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT28 DAYS- THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-WI.4XW1.4 WELDED WIRE FABRIC COMPLYING WITH ASTMA 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116. 7. ALL FIELD FRAMING CONNECTIONS SHALL BE#12-14x3/4"SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHERS. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. 8. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS. 9. CONCRETE ANCHORS SHALL BE I2"x5ln" WEDGE (1/2"x5" TAPCON LOT ON OTHER) ANCHORS OR EQUIVALENT. 10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (2017)- RESIDENTIAL, AND SECTION 1816.1 OF THE FLORIDA BUILDING CODE, SIXTH EDInON (2017) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED. 11. 14 GA FRAMING IS 2-12" x 2.12" TUBE STEEL ITS). NIPPLES ARE 2-1/4" x2-1/4" TS FOR 14 GA FRAMING. 12 GA FRAMING IS 2-1/4" x 2-1/4" TS. NIPPLES ARE 2" x 2" TS FOR 12 GA FRAMING, EXCEPT AS NOTED IN NOTE 4 ABOVE: 1FIRK-3NL-la14LTT_1 APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2017 FLORIDA BUILDING CODE, 6TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER23 WOOD. 2. ASCE 7-10. & SED 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. AC1318 CONCRETE REFRENCE MANUAL & PCI PRECAST& PRESTRESSED CONCRETE. 6. AA ASM 35&AA ADM WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 &TABLE PRODUCTCATEGORY SUBCATEGORY MANUFACTURER APPROVAL No. & DATE STRUCTURAL ROOF DECK CARPORTS ANYWHERE FL27402.1 COMPONENTS HAMPTON RIB ROOF PANEL 8115/18 STRUCTURAL STRUCTURAL CARPORTS ANYWHERE FL27403.1 COMPONENTS WALL HAMPTON RIB WALL PANEL 8115118 EXTERIOR ROLL -UP ASTA INDUSTRIES INC. FL8888.1-R5 DOORS MODEL 203 10/07117 EXTERIOR SWINGING ELIXER DOOR AND FL17996.5-Ri DOORS METAL COMPANY 01129/18 SERIES 407 OCCUPANCY GROUP: CONSTRUCTION TYPE: BUILDING ENCLOSURE TYPE: RISK CATEGORY: ULTIMATE WIND SPEED (MPH): NOMINAL DESIGN WIND SPEED (MPH): WIND EXPOSURE CATEGORY: MEAN ROOF HEIGHT (FEET): ROOF ANGLE (DEGREES): DESIGN PRESSURES (PSF): ROOF: ZONE 1: ZONE 2: ZONE 3: DESIGN ROOF PRESSURES: WALLS: ZONE 4: ZONE 5: DESIGN WALL PRESSURES: SWINGING DOOR: ROLL -UP DOOR: U II-B ENCLOSED I 160 116 D 15.375 14.0 +19.2/30 +19.2/-51.6 a19.2/-44.6 +32.7/-35.4 +32.7143.5 +32.7 / 36.4 +32.71-35.4 +27.31-29.6 CONCRETE NOTE ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE I STRUCTURE q 0 0 CO U33 m cLL oz Z OW m O ZZ aof U) O Z W gN :EALED FASTENERS OR ATTACHMENT' ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD, THESE PLANS AND ALL PROPOSED WO' ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES COVERAGE OF THE REINFORCED STEEL MINIMUM CONCRETE COVER OVER THE REINFORCED STEEL BARS IN THE FOUNONVONS SHALL BE: 3INCHES WHERE THE CONCRETE IS POURED AGAINST AND TEMPORARY IN COMACT WITH THE EARTH OR UNPROTECTED FROM THE EARTH OR WEATHER, OTHERWISE 1-IQ INCHES. REINFORCED BARS SCANNED EMBEDDED IN GROUTED CELLS SHALL HAVE MWIMUM DISTANCE OF 1N INCH FOR FINE GROW OR IQ INCH FOR COARSE GROUT BETWEEN REINFORCED BARS AND PLANE OF THE CELL �� REINFORCED BARS IMPLEMENTED IN THE STONEWORK SHALL HAVE A MASONRY COVER 21NCHES FOR MASONRY UNITS WITH FACE EXPOSED TO THE EARTH OR WEATHER I -In INCHES FOR STONEWORK �1B NOT EXPOSEDTOTHEWEATHEROREARTH. �`, Lucie COUP REINFORCINGSTEM, THE REINFORSING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 2G00 PSI. GALVANIZATION: THE EXTERIOR WALL CONSTRUCTION WITH META -ACCESSORIES THAT DON'T HAVE DIRECT EXPOSING OF WHETHER SHALL BE GALVANIZED ACCORDING TO ASTMA 153, OIASS B-2. SCREWS, SOLTS. PLATE CONNECTORS AND NAILS EXPOSED DIRECTLY TO THE WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED_ REINFORCEMENT MAY BE BEM IN THE FIELD OR SHOP AS LONG AS: 1. IT IS BENT COLD; 2. REINFRCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE REM BEM; 3. THE DIAMETER OF TIE BEND, MEASURED ON THE INSIDE OF THE BAR, IS NOT LESS THAN SIXAAR DIAMETERS. EXCEPTION; WHERE BENDING IS NECESSARY TO ALIGN DOWEL BARS WITH A VERTICAL CELL, BARS PARTIALLY EMBEDDED IN CONCRETE SHALL BE PERMITTED TO BE BEM AT SLOPE OF NOT MORE THAN 1 INCH OF HORIZONTAL DISPLACEMENT TO 6INCHES OF VERTICAL BAR LENGTH. - J J m ao 00 UI M Zzp E U li p U w -J 0 co Cm,{ LU J LL, LFI •C L Z ~I'"Chc 1 a) Ur Z_ 5�O- m H U 0 `n o LL CD N M CV DO T 0 Z I- U W 7 O N 00 W z W % J Z Q W_ D- Q Z Z LLj gQU W m z W O tpza a Of S LU�i- < � `�a: U 0 O5O w LL DATE: 9/24/2018 N 1: DATE PAGE: N 2: DATE NTS i 1 t L 7 16G GE"L NEL BRACE FASTENED TO THE POST AND RPFfER. ?12 FOR 14 WFRPMING WITH RI610-14% W SELF-DRINJNG SCREWS AT EACH END (4 PER BRACE) SEAM CROSS SECTION SCALE: NM TS 1 ROOF PANELATTACHMENT SCALE: NTS FASTENER'S \\\\\`Okl1111111II/, '• •• Nip',, o- :- _ a =C7:V co Q pz m `m _ d v> . z _ T n 3 _ � o ///NIIIIII10\\ U -J d - m c J rn M z z 0 p p U W ODoa, W q 0) I t[1) •C L �• r a) LU C — � M I— •— Z O�-C Q C Q Q VL n� 0LO u- K LU U U N (M co N W T O Z U LLI O FY 0- 11 ii ii ii TO POSTS ACCO0.WNGTO MPNVFACNRER'S WSTµL NONINSTRUCTIONS LU N LL- Q 22'-0" G4LV UOD METALWA PANELS FASTENED Z of O TO POSTS ACCORDING TO MIJIVFACTt RER'S ®-2.5X2.5 INST/ NON INSTRUCTIONS W �y r lL D&VANVEDMETNWALLPANELSFASTFNEO TO POSTS ACCORDING TO MANUFACMNE INSTP1fATON INSTRVC¶ON$ 34' IS'.UCWWNEL BRACE = W Z > O J FAS I]INryz14 T L LL LL DO W�SOn EACH END R PER BRACE) z � rz z W DO l Q Q_ U r m z e e CONCRETE NOTE o O W w ALL OPEN AREAS OF CONCRETE O d O W F- I0 c OUTSIDE OF THE PROPOSED < of r o STRUCTURE SHALL BE DESIGNEDLL G o m o O O)LL TO SLOPE AWAY FROM THE r (J W STRUCTURE SECTION 1 - 1 -.- DESIGN DATE: 9/24/2018 REVISION I: DATE PAGE: 12 REVISION 2: DATE SCALE: NTS NIPPLE TO RARER TS BOX EPV NPFTER 1 CONCRETE BASE RAIL ANCHORAGE SCALE: NM IONST 5 RUCNRA. HEADER OR WINDOW RN TO POST CONNECTION DETAIL SCALE: NTS 12 CA TS PoST NIO NIPFLETO PoBL MIxIMUM IF N. TS.FACE SECUREEACHWITHHIFI2-1Ra W, CEU.RWJNG FASTENEHB 9 HEADEROPOST CONNECTIONDETNI SCA E: NTS MET BOX, E41IENF T WCORNER POST L ED NEOTION DETAIL SCALE: NTS TS 6 END POSTIRAFTER CONNECNON DETAIL SCALE:NTS Tat•T 18CPANGIE CLIP SECURE TO MET MD RARER OR $ RAFTER POSSMBE RNL CONNECION DETAIL SCALE: ME TS RAFTER POST 4 ECNODNPOSTADEERTNLL SCALE: NTS TS TRUSSED RAFTER CHORD.. ORNONSTRUCTURPLHEAOER T�T�T IB OP ANOIE CLIP SECURE TO MST(EACH SDEI AND RNETER CHORDPNLW HF1M a a 1PSDPS. (2) ON BOTTOM AND (T ON 81D E. NOTE: AT ROLL(1P DOOR OPENNGS, MST SHOULD BE FLUSH WITH RNL END. CUP MST TO RAIL ONLY ON DOE OPPOBRE THE OPENING OSTTO NONSIRUCTIIRAL HEADER. BASE, 7 LOR WINDOWRAIL CONNECTION DETAIL SCALE: NIS MIL TSENOMSTORDOOW NNpOWFRANE POST NOTE AT ROLLLP DOOR OPENNGB. POST SHOULD BE FLUSH WITH RAL END, CUP MST TO RNL ONLY ON SIDE OPPOMTETHEOPENINO. TS NONSTR RP- HEA➢ER (12 GA FOR ROLLi1P DOOR FRAUE). BABE RNL OR WINDOW PP1L 8 OSTTONONSTRUCTIIRALHEADERBASE. L OR WINDOW ML CONNECTION DETAIL SCALE:N S ELT. Lu o w - o U) co ............... �11 T— m 00 J Z Z p � U n/ LL p U Lu 0 Do � W Q LL Lo •L ILYL Z ~ W " c ILL— co Z � 0 r c: � Qv(D Q W LL J 0_ N cM co N 00 N Of 0 w , Of Z w OJ W LL Z Q Q Q w U a DO Q Z w 0 w V)—a (L Of o w�F- a D-Inm U c~i 0030 wLL --- DESIGN DATE: 9/24/2018 REVISION 1: DATE PAGE: REVISION 2: DATE SCALE: NTS