HomeMy WebLinkAboutPRODUCT APPROVALSFL# 27402.1
Forcc Engincerrng & Testing Inc.
19530 Ra—hkwoml Drive
H=b1c;rX77333
Product Evaluation Report
CARPORTS ANYWHERE SCANNED
BY
Hampton Rib Roof Panel over open framing. St. Lucie County
Florida Product Approval # 27402.1
Florida Building Code 2017
Per Rule GIG203
Method:1-D.
Category. Structural Components
Subcategory. Roof Deck
Compliance Method: 61G20-3.00S(l)(d)
NON HVHZ
Product Manufacturer:
Carport Anywhere
10858 S.E. County Road 221
Starke, Florida.32091
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID:1920
Validator•
Gary Hartman, P.E. #73227
Contents -
Evaluation Report Pages 1-4
,,,�1rru rr4gri
Nu.4499
SUTEOF
�:o�•AZoltI9A ��.
sv.•arra �i FS • 4
Ja4 e.1.8, z01.8
Fotce Engiitccr' g & Testing Inc.
19530 Itamblewoad Drive
Humble. -IX 77333
Compliance Statement: The product as described In this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2,1504.7.
Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened
structural roof panel. Structural Application.
Panel Material/Standards: Material:
26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50
29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80.
Conforming to Florida Building Code 2017 Section 1507.4.3. Optional paint finish.
Corrosion Resistance: Panel Material shall'comply with Florida Building Code
2017, Section 1507.4.3.
Panel Dimension(s):
Thickness: 26 Ga.; 0.0185" min. order thickness
29 Ga.: 0.0142" min. order thickness
Width: 36" maximum coverage
Rib Height: 'Y." major rib at 9"O.C.
Panel Rallformer. MRS Metal Rollforming Systems
Panel Fastener:
#12-14 x Y.." HWH SD03 with 14mm neoprene banded washing or approved
equal.
Corrosion, Resistance: Per Florida Building Code 2017, Section 1507.4.4.
Substrate Description:
Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel
framing, or Minimum 18 Ga. (Grade 50) Steel framing. See.Table A & B for steel
gauge. Framing must be designed in accordance w/ Florida Building Code 2017.
Allowable Design Pressures:
Table "A" 26 Go. Hambton Rib Roof Panel
Maximum Design Pressure:
-57.3 psf
-72.9 psf
-67.7 psf
+46.9 psf
+54.7 psf
Panel Fastener Pattern:
2-1-2-1
2-1.2-1
2-1-2-1
2.1-2-1
2-1-2-1
Panel Span:
51-D" O.C.
4'-0' O.C.
4'-a' O.C.
5'-0. O.C.
4'-0" D.C.
Substrate:
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
Steel Framing
Min. 16 Ga.
Steel Framing
Min. IS Ga.
.Steel Framing
uesign Pressure includes a Safety Factor -2.0.
FL# 27402.1
,,l{l{IN 121111j
I
�,� E N F.ty ., 10
No. 40
c�f
STATEOF ;
�On.AL01t1�P'•
s"arrros oe -f ., 4;
JM.vt.e,18, 2018
Force Ent gineezrng & Testing Inc.
19530 RamM."Dd DAvc
Humblc;=77338
Table 08" 29 Ga. Hampton Rib Roof Panel
Maximum Design Pressure:
-573 psf
-2509 Psi
+39.0 Fell
+143.1psf
Fastener Pattern:
6"-3'-6"-3"-6"-3"-6"
6"-3'-6'-3"-6"-3"-6'
6'-3"-6'-3"-6'-3'-6'
6'-3"=6"-3"-6"-3'-6"
Fastener5padng:
4'A" O.C.
2'-0' O.C.
4'-0" O.C.
21-W O.0
'Design Pressure includes a Safety Factor -2.0.
Cade Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2017, Section 1504.3.2, 1504.7.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Cade 2017, as relates to Rule 63G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
FM 4471-92 - Foot Traffic Resistance Test
Reference Data: 1. ASTM E 1592-05 (2012) Test
Force Engineering &Testing, Inc. (FBC Organization #TSF-5328)
Report No. 667-0060T-18A-E, 667-0051T-18A-D
2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667-0060T-18F, 667-0061T-18E
3. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Farce Engineering &Testing, Inc.
(FBC Organization # ANE ID: 1920)
Test Standard Equivalency: The FM 4471-10, Foot Traffic Resistance test standard is equivalent to
FM 4471-92.
QualityAssurance Entity: The manufacturer has established compliance of roof panel products In
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
`%,tt t l r S r r t
r�
�%%` U� E�'C E w� r��i
Q-.fit CEp4
too. 4A�
STATE OF
4w
S1 %% ,.
FL# 27402.1
Ju.at.� 18, 2018
i,
Forcc Engincermg &Testing Inc.
1953a Aamhlewood Drive
Humblr,T7t77330
Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2017, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per manufacturer's recommended details.
Insulation:
Manufacturer's approved product (Optional)
Roof Panel Fire Classification:
Fire classification is not part of this acceptance.
Shear Diaphragm:
Shear diaphragm values are outside the scope of this report
Design Procedure:
Based an the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017 for roof cladding
wind loads. These component wind loads far roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2017
Chapter 22 for steel, and Chapter 16 for structural loading.
FL# 27402.1
��'%% tC E tE rr�rer,
No. 449
WATEOF
FLO RI O A
y�`��
Jr41.e,18, 2018
26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1
` #12-14 x 3/4' HWH SD3 VI/ 141AA RONOED NEOPRENE WASHER
I
29 GA. HAMPTON RIB FASTENER PATTERN V-3"-6 -3
I
i
66' 3' 6" 3" 6^ 3'
,912—I4 z 3/4- HWH 503 W/ 14LOA BONDED NEOPRENE WASHER
Swouf Flod6p
QOA.
1p2am
iMN182018
FL# 27403.1
r�FlorceEnt eenng &Testing Inc.
19530 Ra blewood'Drive
Homblc;XX 77330
Product Evaluation Report
CARPORTS ANYWHERE
Hampton Rib Wall Panel over open framing
Florida Product Approval # 27403.1
Florida Building Code 2017
Per Rule 61G20-3
Method:2—B
Category: Structural Components
Subcategory: Structural Wall
Compliance Method: 63G20-3.005(2)(b)
NON HVHZ
Product Manufacturer:
Carport Anywhere
10858 S.E. County Road 221
Starke, Florida 32091
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID.1920
Validator•
Gary Hartman, P.E. g73227
Contents:
Evaluation Report Pages 1-4
SCANNED
By
fit. Lucie County
,`ttttE errrrrr�
sN,C • E I,t,° i��i
STATE OF ;
m.orrrn �i FS .
JV41 zois
Force Engineering &Testing Inc.
19530 Ramble od Drive
Humble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2OV, Sections 1769.2.
Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36" Wide, through fastened
structural wall panel. Structural Application.
Panel Material/Standards: Material:
26 Ga. Steel, ASTM A792 or ASTM A653 690 Grade 50
29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80
Conforming to Florida Building Code 2017 Section 1405.2.
Panel Dimension(s)r Thickness: 26 Ga.: 0.0185" min. order thickness
29 Ga.: 0.0142" min. order thickness
Width: 36" maximum coverage
Rib Height: ''/." major rib at 9" O.C.
Panel Roliformer. MRS Metal Rollforming Systems
Panel Fastener: #12-14 x Y" HWH SD03 with 14mm neoprene banded washing or approved
equal.
Corrosion Resistance: Per Florida Building Code 2017.
Substrate Description: Minimum 14. Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel
framing, or Minimum 18 Ga. (Grade SO) Steel framing. See Table A & B for steel
gauge. Framing must be designed in accordance w/ Florida Building Code 2017.
Allowable Design Pressures:
Table "A" 26 Go. Hampton Rib Wall Panel
Maximum Design Pressure:
-57.3 psi,
-72.9 psf
-67.7 psi
+46.9 psf
+54.7 psi
Panel Fastener Pattern:
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2.1
Panel Span:
5--0" O.C.
4'-0" O.C.
V-0- O.C.
51-W O.C.
4'-W O.C.
Substrate:
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
I Steel Framing
Min. 14 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
Min. 18 Ga.
ISteel Framing
'Design Pressure includes a safety Factor= 2.0.
433`311t 1111
I
C E• E
�A TE OF • �•
:a
'00;,% 1'L0RL9A:�%•
.,, 1 G H I N 1 ?` ,,`
FL# 27403.1
Ju.vt,P� 18, z018
Humble,TX
Table "B" 29 Ga. Hammon Rib Wall Panel
Maximum Design Pressure:
-57.3 psf
-1509 psf
+39.0 psf
+143.1 psf
Fastener Pattern:
16"-3"-6"-3"-6"-3'b"1
6"_3•_6"_3"-6"-3"-6"
6"-3"-6,_3„-6•_3•_6•
6'_3"_6"_3•-6"_3"-6"
Fastener Spacing:
1 4'-0" O.C.
I 2'-O" O.C.
4'-0- O.C.
2'-0" O.C.
-Design Pressure Includes a Safety Factor= 2.0.
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2017, Section.1709.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida, Building Code 2017, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
Reference Data: 1. ASTM E 1592-05 (2012) Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667-006OT-18A-E, 667-0061T-18A-D
2. 'Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Farce Engineering & Testing, Inc.
(FBC Organization NAME ID: 1920)
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Installation: Install per manufacturers recommended details.
Insulation: Manufacturers approved product (Optional)
Panel Fire Classification: Fire classification is not part of this acceptance.
,`,%1111111111.1j
ipo
b 1 C E N S
STATE OF
0 RI 1)
w• pd'rtme. �ii� SS • . G1���
FL# 27403.1
JIA4,&18, 2028
Force Engineering &Testing Inc.
19530 P—mblewaod DAve
Iiumble,TR 77338
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017 for wall cladding
wind loads. These component wind loads for wall cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2017
Chapter 22 for steel, and Chapter 16 for structural loading.
FL# 27403.1
�%%%NtC E'E rr���0
CE
IVSFl,�•
A
STATE OF ;
,e0� FL0RI9A ��
June.18, 201.8
� 1 �
26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1
`e12-14 v 3/4' HNH SD3 W/ 14MM BONDED NEOPRENE WASHER
29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6"
#12-14 a 3/4' WM SD3 W/ 14MM BONDED NEOPRENE WASHER
�o1-E
4�CENSF ;��
N0.44923�` s
STATE 0A •'LW
I (AM 1 8 2018