HomeMy WebLinkAboutEVALUATION REPORTFLH 27402.1 rForce7Engeinccr ng & Testin95aambi.,".d Drivc Humble,TX 77333 Product Evaluation Report CARPORTS ANYWHERE Hamptan Rib Roof Panel over open framing Florida Product Approval # 27402.1 Florida Building Code 2017 Per Rule 61G20-3 Method: 1—D Category: Structural Components Subcategory: Roof Deck Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Carport Anywhere 308S8 S.E. County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID:1920 Validator• Gary Hartman, P.E. #73227 Contents: Evaluation Report Pages 1-4 ,3tt31t111111,I,, 4P�1 CE Ar No. 48nn % ': (I. •a • STATE OF ; q s cn� rrrFS., SC.A St Cucl® Go nhr Ju,Hz1-8, 203.8 i; LJ Force Engineering & Testing Inc. LJ 19530 Ramblcwood Ddve Humblc,TC 77333 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2,1504.7. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened structural roof panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1507.4.3. Optional paint finish. Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: 34" major rib at 9" O.C. Panel Rollformer: MRS Metal Roliforming Systems Panel Fastener: #12-14 x '/," HWH SD#3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017, Section 1S07.4.4. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga. Hampton Rib Roof Panel Maximum Design Pressure: -57.3 psf -72.9 psf -67.7 psf +46.9 psf +54.7 psf Panel Fastener Pattern: 2-1-2-1 2.1.2.1 2-1-2.1 2-1-2-1 2-1-2-1 Panel Span: 5'-o" O.C. 4'-0" O.C. 4'-0" O.C. 5'-0" O.C. 4'-0" O.C. Substrate: Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing *Design Pressure includes a Safety Factor =2.0. ,:bQ-Q ;4t CEpSF<�i H,. �� F� * STATE OF : m i FL# 27402.1 JU41-ems 19, 2018 TF Force Engineering &Testing Inc. 19530 Rnmblewood Drive Humblc,TX 77330 Table "B" 29 Ga. Hamoton Rib Roof Panel Maximum Design Pressure: -57.3 psf' -150.9 psf +39.0 psf +143.1 psf Fastener Pattern: 6"-3"-6"-3"-6"•3"-6" 6"-3"-6"-3"-6"-3"-6" 6"-3"-6"-3"•6"-3"-6" 6"-3"-6"-T4- 3"-6" Fastener5pacing: 4'-0" O.C. T-0" O.C. 4'-0- O.C. 2'.0" O.C. *Design Pressure includes a Safety Factor=2.0. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: = ASTM E 1592.05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference • FM 4471-92 - Foot Traffic Resistance Test Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization #TST-5328) Report No. 667-006OT-18A-E, 667-0061T-18A-D 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization 9 TST-5328) Report No. 667.0060T-18F, 667-0061T-18E 3. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: The FM 4471-10, Foot Traffic Resistance test standard is equivalent to FM 4471-92, Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. settsuunrrrq i C.. Ji �.�•IW.449�v STATE OF ; i P 4 0a.pL0R19A 4� usrm r�'t4l OHnt• L N,%sa FL# 27402.1 JM 4%e$ 18, 2-018 Force Engineering Ec Testing Inc. 19530 Romblewaad Drive 14um61c,TX 77330 Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. i Installation: Install per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. FL# 27402.1 t�3nurrtrrrr `� 4��1 CEPfSF,IT+� N.. a4s� �'^• SPATE OF ;rr� 04,� A 'Al Jtn.v& 18, 2.01-5 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 12—I4 . 3/4" IIWH SD3 V7/ I41AM BONDED NEOPRENE V/ASHCR 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6" 6 3 6�. _ 31. 6.. 3. 1112-14 . 3/4" HWH S03 4f/ I'Mi BONDED NEOPRENE WASHER OIota of FlmiAO ROJ6 asm [rEF rrrrp/rp��� i Ns N!o. 44923 ° STATE OF 9DI 1 8 2018 SCANNED Ltacie Coup Force Engineering & Testing Inc. ty 19530 R..bl.00d Dclve Humble,TX 77338 Product Evaluation Report CARPORTS ANYWHERE Hampton Rib Wall Panel over open framing Florida Product Approval # 27403.1 Florida Building Code 2017 Per Rule 61620-3 Method: 2—B Category: Structural Components Subcategory: Structural Wall Compliance Method:61G20-3.005(2)(b) NON HVHZ Product Manufacturer: Carport Anywhere 10858 S.E. County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation AN ID: 1920 Validator• Gary Hartman, P.E. #73227 Contents: Evaluation Report Pages 1-4 t,NE, tC E r rrt rti� S% @ ..... h,0 oe CE ja STATE OF : o; i ' o4 .,,,� . FL o It1 ID P �+4 % i ��� F `r,r - aV ��� warm ��I SOH nr1� O`, FL# 27403.1 JIA nPi 18, 203.8 rForce Engineenng &Testing Inc. 19530 Aamblewood Drive Humblc,TX 77333 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1709.2. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36" Wide, through fastened structural wall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1405.2. Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: '''/" major rib at 9" O.C. Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: #12-14 x Y." HWH SD#3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga. Hampton Rib Wall Panel Maximum Design Pressure: -57.3 psf -72.9 psf -67.7 psf +46.9 psf +54.7 psf Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 Panel span: 5' 0" O.C. 4'-0" O.C. 4'-0" O.C. 5'-0" O.C. 4'-0" O.C, Substrate: 14 Ga. Steel Framing Steel Min. 14 Ga. Steel Framing Min. 14 Ga. I Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing "Design Pressure includes a Safety Factor = 2.0. %% N,C E' E r I r�r. O Pi C E N S F •O �: li'� � •. ems- 40, e STATE OF AL O RI 1) irOHrrtstw`a FL# 27403.1 Jiutz18, 2018 Force Engineenng & Testing Inc. 19530 Ramble ,00d Drive Hemblc,TX 77339 Table "B" 29 Ga. Hampton Rlb Wall Panel Maximum Design Pressure: -57.3 psf -150.9 psf +39.0 psf +143.1 psf Fastener Pattern: 6"_3"-6"-3"-6"-3"4" 6"-3" 6"•3" 6"-3"-fi" 6"-3"-6"-3" 6" 3"-6" 6"-3"-6"-3"-6"-3"-6" Fastener Spacing: 4'-0" O.C. 2'-0" O.C. 4'-0" O.C. 2'-D" O.C. -Design Pressure Includes a Safety Factor= 2.0. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 667-D060T-18A-E, 667-0061T-18A-D 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization q ANE ID: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturers recommended details. Insulation: Manufacturer's approved product (Optional) Panel Fire Classification: Fire classification is not part of this acceptance. ,ttttl111 rlllr7j' 6N,C E. C 8 At ^r' STATE OF - sxxmrms 10O Of • FL 0 RI I) 1 * , �rpm's et��G% FL# 27403.1 jv-o_e 18, 2018 Force Engineering &Testing Inc. 10530 Rumbi..d Drive Humble,TX 77338 Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for wall cladding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. .♦♦♦,♦H C E t E r rrr��i ♦♦ E . ... , iYp �i A Flo. 4N % !b• STATE oP :q Qj ID fi ..♦ At A 41 F . 0 RL ..g♦♦� • .. Cf ♦ •xrm ��r SOH ntt0 ♦♦♦♦ FL# 27403.1 ' Ju.vl.e-18, 2D18 D 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 #12-14 x 3/4' HWH S03 W/ 14MM BONDED NEOPRENE WASHER 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6" 6 -.-3 -,- 6.. '_3-.- 6. _._3_._ 6' 3, #12-14 x 3/4" HWH SD3 W/ 14LIM BONDED NEOPRENE WASHER CElEuip��:conuaaa N :UIffm Ro.44923 ••�� % n 13 ', STATE 0 O 1(JON182018