Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFILE COPY' FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 'Project Name: POLK RESIDENCE Builder Name: GEMBUILDERS Street: 5204 CITRUS AVENUE Permit Office: ST LUCIE COUNTY city, State, Zip: FORT PIERCE, FL, Permit Number: Owner. I CAMILLE POLK Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St Lucie (Florida Climate Zone 2 ) 1. New construction or eldsting Now(From Plans) � 9. Wall Types(2016.0 sgft.) Insulation Area 2. Single family ar multiple family Single-family a. Frame -Wood, EMedor R=19.0 1968.00W Is. Frame- Wood, Adjacent R=11.0 48.00 ft2 3. Number of units, If multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. WA R= ft2 6. Is this a worst case? No 10.Ceding Types (1932.0 sq8.) Insulation Area a. Under Attic (Vented) R-30.0 1932.00 ft2 6. Conditioned floor area above grade (ft2) 1932 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 R III.Ducts R ft2 7. Windows (484.0 sgft.) Description Area a. Sup: Attic, Rot Attic, AH: Attic 6 125 a. U-Factor: Dbl, U=0.65 251.00 ft2 b. Sup: Attic, Ret Attic, AH: Attic 6 125 SHGC: SHGC=0.20 b. U-Factor. Dbl, U=0.70 233.00 ft2 12. Coding systems - k8bAr Efficiency SHGC: SHGC=0.30 a Central Unit 18.8 SEER16.00 c. U-Facto: NIA ft2 b. Central Unit 18.8 SEER:16.00 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Facto: WA ft2 a Electric Strip Heat 17.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 2.905 a. Area Weighted Average SHGC: 0.248 14. Hot water systems 8. Floor Types (1932.0. sqft.) Insulation Area a. Electric Cap: 40 gallons a. Raised Floor R=30.0 970.00 112 b. Conservation features EF: 0.980 b. Slab -On -Grade Edge Insulation R=0.0 962.06 ft2 None c. NIA R= fP 15. Credits None Glass/Floor Area: 0.251 Total Proposed Modified Loads: 63.52 c c PASS Total Baseline Loads: 65.01 rMa7a7 1 hereby certify that the plans andspecifications covered by Review of the plans and SpgT� this calculation are in compliance with the Florida Energy specifications covered by this OFKBE �. § 0�, Code. calculation indicates compliance with the Florida Energy Code. PREPA E BY: Before construction is completed ul DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that building, as d tiny(, is i 1 compliance Florida Statutes. I,j, with the Florida Ene C/��a It fop Y1,Eq¢J OWNER/A ENT �2f BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNETIICC 380, is not greater than 0.030 On for whole house. 1116/201810:23 AM EneWOauge0 USA Section R405.4.1 Compliant Software Page 1 of 7 :ORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: POLK RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area 1932 Lot#. Owner Name: CAMILLE POLK Total Stories: 2 BlorklSubdivislon: #of Units: 1 Worst Casa: No PlalBook: Builder Name: GEM BUILDERS Rotate Angle: 0 Street 5204 CITRUS AVENUE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE. Family Type: Single-family FL, NewlEidsting: Now (From Plans) Comment: CLIMATE / Design Temp Int Design Ternp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fart Pierce FL VERO_BEACH _MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 2 970 7760 2 AHU 1 962 7696 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 KITCHEN 240 1920 Yes 0 1 Yes Yes Yes 2 BATH 56 440 No 0 1 Yes Yes Yes 3 OFFICE 117 936 No 0 1 Yes Yes Yes 4 HALL 24 192 No 0 1 No Yes Yes 5 FAMILY ROOM 357 2856 No 0 1 Yes Yes Yes 6 DINING ROOM 168 1344 No 0 1 Yes Yes Yes 7 WIC 24 192 No 0 1 Yes Yes Yes 8 BATH 2 40 320 No 0 1 Yes Yes Yes 9 BEDROOM2 156 1248 No 0 1 1 Yes Yes Yea ' 10 M WIC 30 240 No 0 1 Yes Yes Yes 11 WfD 12 96 No 0 1 No Yes Yes, 12 MASTERBEDROO 198 1568 No 0 1 1 Yes Yes Yes 13 M BATH 119 952 No 0 1 Yes Yes Yes 14 HALLWAY 141 1128 No 0 1 Yes Yes Yes 15 BEDROOM 3 155 1248 No 0 1 1 Yes Yes Yes 16 STAIRS 96 768 No 0 1 Yes Yes Yes 1116201610:23 AM EnergyGaugeO USA Section R405A.1 Compliant Software Page 2 of 7 VORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space. Pedmeler Perimeter R-Vaue Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation 'KITCHEN 25 ft 0 240 ft' 1 0 0 2SIab-On-Grade. Edge Insulation BATH 8 R 0 56 it- __ 1 0 0 3 Slab -On -Grade Edge Insulation OFFICE 22ft 0 117 fP __ 1 0 0 4 Slab -On -Grade Edge Insulation HALL 1 R 0 24 fl' e 1 0 0 5 Slab -On -Grade Edge Insulation FAMILY ROOM 38 ft 0 357 tt' --_ 1 0 0 651ab-On-Grade Edge Insulation DINING ROOM 26R 0 168 fP — 1 0 0 7 Raised Floor WIC 3 __ — 24 fP 30 1 0 0 8 Raised Floor BATH 2 _ __ 40 ft' 30 1 0 0 9 Raised Floor BEDROOM2 __ 156 it- 30 1 0 0 10Ralsed Floor M W IC — __ 30 fI2 30 1 0 0 11Raised Floor W!D ._ 12 ft' 30 1 0 0 12Raised Floor MASTER BEDRO — _ 196 ft. 30 1 0 0 13Raised Floor M BATH — _ 119 R' 30 1 0 0 14RWsed Floor HALLWAY — _ 141 ft' 30 1 0 0 16Raised Floor BEDROOM 3 — _ 156 ft' 30 1 9 0 16Raised Floor STAIRS — — 96 ft' 30 1 0 0 ROOF " Roof Gable Roof Solar SA Emitl Emig Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2161 ft' Oft' Medium 0.3 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vem Ratio (1 in) Area FIBS IRCC 1 Full alto Vented 150 1932 ft' N N 110201810:23 AM EnergyGaugoO USA Section R405.4.1 Compliant Software Page 3 of 7 e. IA IlJ IN I' IO Im Im IV IW IN IA IN IN I+ Im Im Im IV Im IN IA I41 IN I+ z mm c- zz CD m-m mm m m z. z m..m7- (zn m tt �mn tt �m7 # m� mm mm: mz mz > > > ? > > > > > > > > > > > m II E nm A tt A ii LL ti 2i 2S S tS R .> s �• n• n• a. �• � m m A i m m� m m m m m m� 3 3 3 8 8 8 8 $ E. $ 8. i -8 - Q� Qi Qi 5�� Q� Q Q� p�p 5�Q� p� 5e� Q`eQ QF 5�� as pfp pi QcQ qQe QFQ m to xb ; g m m m m o o y T > T m x m z T 0 o o F 3 3 N flDl `2 z z 3 3 o 'n O '�+� y � —may' m i o• D m e o y g z O< m 'n m -i O O D a m m�m 0 0 C] .n 0< -DI x x x x �i > O D p a e 0 'q i n O " m m x m 3{ O w 00 00 z m CD 3 x x m m a ^' o o o o z z z z m x o ^' .� m m m N N 0 o O o o i 0 s oo 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o m m m_ ggm 9m_9 gmg 4m_4 4mg _ggm gm_g g@m_ gmg_ gm_g 4m_g pmp gm_g � m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �• o 0 0 0 0 o a o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 .0 0 0 0 0 0 0 0 0 0 0 0 .a T a 0 0 0 0 0 0 0 0 0 0 0 0? o 0 0 0 0 0 0 0 0 0 0 w m O O m m m o 0 0 m 0 0 0 W O O m W 0 0 0 0 0 O O p Q Oa O$ g 6 m O O O O O 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 m O 0 qm a m Z C VJ C am n S n A r X m IV O I� F. O IL w rid J Y W V Q cn N m z m 5 d e d c d e d c d d N p d d N N e d c d c d d c d c d c d c d c d c d c 3S Z Z Z Z Z Z Z Z Z z° Z Z Z Z Z Z Z Z Z N N ul w N y C m p d d d d d d d d d d d d d O d d d d d H 'g Z Z Z Z O Z O O Zm Z OO Zm y G G Z O Z O Z O O Z O Z O Z O Z O Z O Z O Z O Z _ IL m C 9 ' ❑ ❑` N N r C y C C G C C C C C C G C C C C C C C G C C C Q C C C C C C C C C C C C C U m m m m m m o Co m o m m m m m m m m m m m w x e C C C C C o C C' C C C C C C C C C C 2 Q n y m 5 4 ti C C C Z2: Z: E ?yd C m C CI CI o m O O o 0 0 o m O o o m o 0 o O o CC, o �1 .N- z d W � m z 2 E ZO w N (❑9 M co n m m N M m n n N N N N H N N N N N n� R fa g1 m ?a s r r r r r r r r r r m m IQIII g m q O O i y LL O O O O OO O O O O O O O O O O O O O O O O LL Z_ � N noj W L U d ❑ 5 a � o y 43 n ❑ 0 0-9 0 0 0 0 0 0 0 m ❑ O ❑ D ❑ ❑ ❑ O ❑ O ❑ ❑ D ❑ ❑ ❑ ❑ ❑ ❑ O ❑ a wy5 wyS wy5 wyy w w w wys w Jw w w w$O uyp�y w w w wz6z w w$$ w ❑ C J J J J J J J J J J J J 1pO C C C C C C C C C G C N Q 3 �❑O- a` Ez W w z z;2: N 7� w N w w w co Z z w z m iG N f7 O N m r m m m = 3 �c 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM Vf # System Type Subtype Efficiency Capacity Block Ducts _ 1 Electric Strip Heatf' None COPA 17 kBlulhr 2 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtulhr 1- sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow. SHR Block Ducts _ 1 Central Unit/ Split SEER: 16 18.8 k6tu1hr 664 cfm 0.8 2 sys#1 2 Central Unit/ Spin SEER: 16 18.8 kBtulhr 564 cfm 0.8 1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart# Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS / — Supply— — Return— AV CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 125 fP Attic 13 ft- Prop. Leak Free Attic — cfm 28.9 cfm 0.03 0.50 1 1 2 Attic 6 125 fP Attic 13 it' Prop. Leak Free Attic — cfm 29.1 cfm 0.03 0.50 2 2 TEMPERATURES Pmgramableji Cfeilling Fans: j)hermostatff Heating [X] 11N Jan [X1 Feb �� 11 iXi Mar I 1 f 1 Apr fXI fXI f) 1 1 Jun f 1 Jul [X1 [ l Aug [XJ l 1 Sep � Oct [jXi] Nov f(X11 Doe venting [I ]1 Jan II 11 Feb [[�X11'.Mar IXl May [) [ 1 Jun I 1 Jul [ 1 Aug l 1 Sep [� [ j Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)I AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 - 78 78 80 80 80 80 PM 80 80 8D 80 78. 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 .68 68 68 68 68 11IM01810:23 AM EnergyGauge® USA Section R405A.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Ttflckness Furniture Fraction Space Defaull(81bs/sq.ft. of Oft 0.3 BREAKFAST Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft. ft 0.3 PANTRY Default(8 lbslsq,ft fl' ft 0.3 GREAT ROOM Defauft(8lbs/sq.ft fF ft 0.3 BATH 2 Default(8 lbs/sq.ft ft' ft 0.3 HALL2 Default(B lbs/sq.ft fN ft 0.3 FOYER Dafaull(8lbslsq.ft ft. ft 0.3 DEN Default(8 lbs/sq.tL fP ft 0.3 WIC Default(S Ibslsq.ft ft2 ft 0.3 WIC 3 Default(B Ibs/sq.ft it' ft 0.3 BEDROOM 2 Defauk(B lbs/sq.ft fF ft ,. 0.3 BEDROOMS Default(8 Ibslsq.fL W ft - 0.3 M BATH Default(B lbs/sq.ft fP ft 0.3 - M CLST Default(8 lbs/sq.ft ft' it 0.3 M HALL Defeult(8 lbs/sq.ft IF ft 0.3 MTOILET Default(B lbs/sq.ft W ft 0.3 M WIC 1 Default(B lbs/sq.fL ft' It 0.3 MASTER BEDROO Default(B lbslsq.fL ft' R 0.3 M W IC 2 Default(8 lbs/sq.ft ft' ft 0.3 CABANA BATH Default(8 lbs/sq.ft fe R 0.3 HALL Default(8 lbs/sq.fL fe , ft 0.3 STORAGE Delanit B lbs/s .ft fl' It 0.3 UTILITY Name: Signature: _CMOFQ2�— Rating Compant: Date: 1901 11161201E 10:23 AM EnergyGaugeO USA Section R405A:1 Compliant Software Page 7 of 7 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: POLK RESIDENCE Builder Name: GEM BUILDERS Street: 5204 CITRUS AVENUE Permit OFflce: STLUCIECOUNTY City, State, Zip: FORT PIERCE, FL, Permit Number. Y U Owner. CAMILLE POLFC Jurisdiction: ST LUCIE COUNTY = Dwlgn Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Alr-permeable insulation shall The exterior thermalemelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or Joints in the air bonier shall be sealed. Celling/attic The air barrier in any dropped cellIng/soffit shall be aligned with the The insulation in any dropped ceilinglsoffit Insulation and any gaps in the air bander shall be sealed. shag be aligned with the air harrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sir plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exteriorwalls shall be sealed. shall be Insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, slrtfights The space between windowldoorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air harder. Rim joists shall be insulated. Flocra The air barrier shall be Installed at any exposed edge of insulation. Floor framing cavity Insulation shall be Installed to (Including maintain permanent contact with the underside of abo"arage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous Insulation Installed on the underside of floor framing and extends from the boo to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shalt be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlepaca walls. Stunts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, a narrow Narrow cadties cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed right fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywafl. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut nea0y to fit around wiring plumbing in exterior wails, or insulation that an Installation readily conforms to available space shall extend behind Pining and whin . Showerltub,. The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tuffs. insulated. Electricallphone box on The air barrier shall be Installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-noor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed J sprinklers In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover afes and walls or Wrings.I a. In addition, Inspection at log IS shall be in accordance with the provisions of,ICC-400. 11/61201810:24 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ', FILE Cr. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATEDENERGY PERFORMANCE INDEX'= 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans). 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Sirjgle-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 37.6 a) Split system SEER 16.0 5. Is is a worst case? (yes/no) 5. No b) Single package SEER c) Groundwater source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1932 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.674 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.248 c) Area 7c. 484.0 8. Skylights a) U-faotor.(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9..Floor type, insulation level: a) Slab -on -grade (R-value) b Wood, raised (R-value) c) Concrete, raised. (R-value) 10. Wall type and insulation: A. Exterior: 1'_ Wood frame (Insulation R-value) 2i Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) i Masonry (insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly s c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 30.0 9c. 10A1. 19.0 10A2. 14. Heating system: Capacity 34.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system With tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 10B1. 11.0 110132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0, b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multimne coating credit 11d. Not e) Multizone heating credit f) Programmable thermostat No 'LabI at required by Section,R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I celify that this home has complied with the Florida. Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display cc/arrd�will be completed based on i stall d code compliant features. �y/lP "r Signature: �? VV Date: Address of New Home: 5204 CITRUS AVENUE City/FL Zip: .FORT PIERCE. FL 11161201810:23:57 AM EnergyGauge® USA 6.0.02- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Pro ect Summary DaL wrightsoft® AH1 FILE LE DaLe: NOV. 6, 2018 QUICK CALCS, INC. �/� 317 ST LLICIE LANE, FORT PIERCE, FL 34M Phone: 772 .66-6799 Fax 772-466-6796 Emil: OUCKCALCS@AOLCOM For: kin M- 5204 CITRUS AVEN ECE E FBUILDERS RT PIERCE, FL Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gdlb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12510 Btuh Structure 11571 Btuh Ducts', 2340 Btuh Ducts 2083 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Stuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14851 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipmerf sensible load 12971 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2550 Btuh Ducts 932 Btuh Central vent (0 cfm) 0 Btuh Area (ft2) Heat' 962 Coolingg 962 (none) Equipment latent load 3482 Btuh Volume ($3) 7696 7696 Air changes/hour 0.45 0.20 Equipment Total Load (Sen+Lat) 16453 Btuh Equiv. AVF (cfm) 58 25 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567539 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 4.4 kW Sensible cooling 13160 Btuh Heating output 14856 Btuh Latent cooling 5640 Btuh Temperature rise 22 OF Total cooling 18800 Btuh Actual airflow 627 cfm Actual airflow 627 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4 Ilw_rightsoft- 2018-NbvW6 10:22:44 RightSuite® Universal 2018 18.0.31 RSW8101 Page 1 E:1Dooumnets\Wrightsoft FNAC\POLK RESIDENCErup Colo= MJ8 Front Door faces: W Project Summary Job: wrightsoftAHU 2 N Byte: NOV.s, zota QUICK CALCS, INC. 317 ST LUCIE LAPS, FORT PIERCE, FL 34946 Phone: 772-4666799 Fax 7724666796 Email: OLICKCALCS@AOLCOM For: 5204 CITRUS AVENUE, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 8763 Btuh Structure 9796 Btuh Ducts 2342 Btuh Ducts 3513 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping1 0 Btuh Equipment load 11104 Btuh Use manufacturer's data n Rate/swing multiplier Equipmerlf load 0.95 12643 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2902 Btuh Ducts 931 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cool in�gg IM (none) Area (ft2) 970 Equipment latent load 3834 Btuh Volume (fta) 7760 7760 Air changesthour 0.47 0.20 Equipment Total Load (Sen+Lat) 16477 Btuh Equiv. AVF (cfm) 60 26 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567539 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 2.9 kW Sensible cooling 13160 Btuh Heating output 9846 Btuh Latent cooling 5640 Btuh Temperature rise 14 OF Total cooling 18800 Btuh Actuall air flow 627 cfm Actual air flow 627 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static ipressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 46 �,wrlgli 2018-Nov0610:22:44 r•^w•--^•^^^••�• Right -Suite® Universal 2018 18.0.31 RSU08101 Page 2 p` E:IDocumnetslWrightsoft WACIPOLK RESIDENCE. mp Cale = MA Front Door races: W wrightsoftRight-M Worksheet Dab AHU 1 Date: NOV. 6, zole By: QUICK CALCS, INC. 317 ST LUCIE LAhF, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCWOL.COM 1 2 3 4 5 Room name Elq: sed wail Room height Room dimensions Room was AHU 1 120.0 R 8.0 fl 962.0 fP 14TCHEN 26.0 R 8.0 It heat/cool 20.0 x 12.0 it 240.0 fY Ty Construction number U-value (BtuWft%'F) Or HTM Area (02) or perimeter lit) Load (Bluh) Prey (11� or perimeter (ft) Lead (Btuh) Heat Cool Gross WP/S Heal Cool Gross WP/S Heal I Cool 6 11 UJ FLU--CG 1215-0sw 2 glazing, clr lwfe 2 glazing, dr hrre 2 glazing, clr Iwr-e 12E-0sw 2 glazing, dr lowe 2 glazing, dr low-e 2 glazing, clrlori-e 2 glazing, clr Iowa 12E-Om 2 glazing, clr lova-e 2 glazing, clr lowe 12E-Osw 2 glazing, cir lory 2 glazing, dr lave 11DO 16030ad 71Mph 0.068 0.700 0.70D 0.650 0.700 0.700 0.650 O.fi50 0.650 0.0w 0.700 0.650 0.089 0.700 0.650 0.390 0.032 1.358 In n n n a a a a a s s s w w w w - - 1.90 19.60 19.60 0.00 9.60 19.60 10.00 0.00 0.00 1.90 19.60 0.00 1.90 19.60 0.00 10.92 0.90 38.02 1.18 16.79 16.79 0.00 1.33 39.33 30.03 0.00 0.00 1.18 13.24 0.00 1.18 39.33 0.00 10.34 1.60 0.00 200 6 30 0 12 212 45 0 0 232 82 0 272 60 0 20 16 962 164 0 0 0 19a 0 0 0 0 150 82 0 192 0 0 20 16 120 312 118 58B 0 235 882 880 0 0 286 1599 0 365 1176 0 223 14 4563 194 101 504 0 472 770 1n0 0 0 178 1080 0 227 2360 0 211 26 0 64 0 15 0 112 12 15 0 0 0 0 0 (1 0 0 0 0 240 49 0 0 0 110 0 0 0 0 0 0 0 0 0 a 0 a 26 93 0 294 0 235 294 294 0 0 0 0 0. 0 0 0 0 0 989 - 56 0 252 0 138 472 5w 590 0 a 0 0 0 0 0 0 0 0 0 G 11 V W 11---w I--G C F 6 c)AED elawrsion 0 -293 Envelope loss/gain 10740 7357 2128 1217 12 a) Infiltration 1770 414 383 90 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 38M 2400 Subtotal (lines 6 to 13) 12510 11571 2511 3M7 Less external load 0 0 0 a Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 12510 11571 2511 3707 15 Dud loads 19Yo 18% 2340 2063 19% 1BV 470 667 Trial room load 14851 13654 2981 4374 Air required (rim) 627 627 126 201 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c -Fk- wrlghisofi- 2018-Nov-061022:44 RightSuite@ Universal 2018 18.0.31 RSU08101 Page 1 E9DocumnetslWdghtsoft INACIPOLK RESIDENCEmp Cale = MJ8 Front Doorfaces: W wrighi+softRight-M Worksheet Job: V. AHU 1 Date: NOa, 2o1a By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: ONCKCALCS@AOLCOM 1 Room name BATH OFFICE 2 Exposed wall 8.0 0 22.0 R 3 Room height 8.0 0 heaticod 8.0 ft heaticod 4 Room dimensions 7.0 x 8.0 ft 13.0 x 9.0 ft 5 Room area 56.0 IF 117.0 ft- Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number (Btuhfft?°F) (BIWftT) or pedrreter (ft) (Bluh) or perimeter (f) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WPIS Heat Cool 6 lyV 12E-Om 0.068 n 1.90 1.18 64 58 110 69 72 57 109 67 ILL-ICGa 2 glazing, cir love 0.700 n 19.60 16.79 6 0 118 101 0 0 0 0 2 glazing, dr Iowa 0.700 n 19.60 16.79 0 0 0 0 15 0 294 252 2 glazing, cir Iowa 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 11 12EOw 0. a 1.60 1. 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.700700 a 19.60 39.3333 0 0 0 0 0 0 0 0 2 glazing, cir Iwr-e 0.0 a 19.60 3.03 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.650 a Q00 0.00 0 0 0 0 0 0 0 0 0 2 alazinq, cir love 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 W, 12E-Osw 0.068 s 1.90 1.18 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.700 s 19.60 13:24 0 0 0 0 0 0 0 0 L�-GC 2 glazing, co- lc n e 0.650 s 0.00 0.00 0 ', 0 0 0 0 0 0 0 12E-Osw 0.068 w 1.90 1.18 0 0 0 0 104 74 141 88 2 glazing, cir love 0.700 w 19.60 39.33 0 0 0 0 30 0 5w 1180 2 glazing, dr lowe 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 11DO 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C 16B3Wd 0.032 - 0.90 1.60 0 0 0 0 16 16 14 26 F 22A4ph i 1.358 - 38.02 0.00 56 8 304 0 117 22 837 0 61 c)AED excursion -29 1 324 Envelope lass/gain 532 140 1982 1936 12 a) Infiltration 118 28 324 76 b) Room venfiatim 0 0 0 0 13 Internal gains: Occupants @ 230 0 _ 0 0 0 Appriancestother 200 0 Subtotal Qines 6 to 13) 650 368 2307 2012 Less erdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 650 368 2307 2012 15 Duct loads 19% 18% 122 fib 19°/ 18% 432 362 Total room load 1 772 1 434 2738 2374 Air required (don) 33 20 116 109 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -PWwrrghisoTi- 2018-Nov 06 10:22:44 RightSuiteO UnNema12018 18.0.31 RSt108101 Page 2 E:\Documnets%Wrightsot WACIPOLK RESIDENCE.mp Calc = M.18 Front Door faces: W F wrightsoftRight-M Worksheet Job: AHU 1 Date: NOV. 6, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-066-6799 Fax 772-066-6796 Email: OtfiCKCALCS@AOLCOM 1 Room name HALL FAMILYROOM 2 Engxsed wall 0 ft 38.0 it 3 Room height 8.0 ft heallcod 8.0 n heaVcool 4 Room dimensions 6.0 x 4.0 it 21.0 x 17.0 ft 5 Roam area 24.0 fF 357.0 ft' TY Construction U-value Or HTM Area (n2) Load Area (ni) Load number (Bluh/ftMF) (Ouhfft� or perimeter (it) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WPIS Heat Cool Gross WPIS Heat Cool 6 12E-DvN 0.068 n 1.90 1.18 0 0 0 0 0 0 0 0 G. 2 glazing, cir low¢ 0.700 n 19.60 16.79 0 0 0 01 0 0 a 0 2 glazing, cir Icwe 0.700 n 19.60 16.79 0 0 0 0 0 0 0 0 2 glazing, dr lode 0.650 n 0.00 0.00 0 0 0 0 0 - 0 0 0 i i 12E-0sw 0.068 a 1.90 1.18 0 0 0 0 a o 0 0 Iw - I---t� 2 glazing, dr lone 0.700 a 19.60 39.33 0 a 0 0 0 0 0 0 2 glazing, cir lc to 0.700 a 19.60 39.33 0 0 0 a 0 0 0 0 2 glazing, or loose 0,650 a 0.00 0.00 0 0 0 0 0 0 0 0 III---G. 2 olazim, cir lowe 0.650 e 0.00 0.00 0 0 0 0 0 0 0 0 w 12Esw -0 0.068 s _ 1.90 1.18 0 0 0 0 136 95 181 113 2 glazing, cir lave 0.700 s 19.60 13.24 0 0 0 0 41 41 BID '540 2 glazing, cir lorse 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 lyY 12E-0sw 0.068 w 1.90 1.18 0 0 0 0 168 lie 224 139 �--G �LGD 2 glazing, cir lave 0.700 w 19.60 39.33 0 0 0 0 30 0 sea 1180 2glazing, dr lave 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 11DO 0.390 w 10.92 10.34 0 0 0 0 20 20 223 211 c 16B30ad 0.032 - 0.90 1.60 a 0 0 - 0 o 0 0 0 F 22A4ph i I 1.358 - 38.02 0.00 24 0 0 0 357 38 , 1445 0 6 c)AED excursion 0 143 Fmelope bss(gain 0 0 3461 2325 12 a) Infiltration 0 0 560 131 b) Rcomventilation 0 0 0 0 13 Internal gains: occupants @ 230 0 0 0 0 Apptlancesnother 0 1200 Subtotal (Ines 6 to 13) 0 0 4021 3657 Less edernal load 0 0 a 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 4021 3657 15 Duct loads 19% 189/6 0 0 19% 1 18% 752 658 Total room load 0 0 4773 4315 Air required (cfm) 0 0 202 198 Calculations approved birACCA to meet all requirements of Manual J 8th Ed. ,� -pp-wr19F+isoTe- 2018-Nov-0610:22:44 A`A RightSuite® Universal 2018 18.0.31 RSU08101 Page 3 E:\DocumnetslWdghtsoft HVAC\POLKRESIDEN--E.mp Caic=MJ8 Front Doorlaces: W +wrighUoft° Right-M Worksheet Job: AHU 1 Date: NOV. 6, zote By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77246SV99 I'm 77246W96 Email: QUCKCALCS@AOLCOM 1 Room name DINING ROOM 2 Exposed wall 26.0 ft 3 Room height 8.0 ft heaUcool 4 Room dimensions 14.0 x 12.0 R 5 Room area' 168.0 ft2 Ty Construction U-value Or HTM Area M Load Area Load number (Btufdit2-°F) (&uwfP) or perimeter (ft) (Bluh) or perimeter Heat Cool Gross WP)S Heat Cool Gross NURIS Heat Cool 6 12E-0sw 0.068 In 1.90 1.18 0 0 0 0 2 glazing, clr lc a 0.700 n 19.60 16.79 0 0 0 0 2 glazing, cir love 0.700 n 19.60 16.79 0 0 0 0 2 glazing, clrlava 0.650 n 0.00 0.00 0 0 0 0 it W 12E-0sw 0.058 a 1.90 1,18 112 82 155 97 2 glazirg, clr Iarre 0.700 a 19.60 39.33 0 0 0 0 2 glazing, clr lave 0.700 a 19.60 39.33 30 0 588 1180 2 glazing, clr love 0.650 a 0.00 0.00 0 0 0 0 2 plazina. clr loare 0.650 a 0.00 0.00 0 0 0 0 --' 12E-0sw 0.06E s 1.90 1.18 96 55 105 65 IW 'I--' LS 2 glazing, clr lvrve 0.700 s 19.W 13.24 41 41 800 w 2 glazing, clr lowe 0.650 s 0.00 0.00 0 0 0 0 W 12E-0sw 0.068 w 1.90 1.18 0 0 0 0 Ill---��,+ glazing, clr Iw 0.700 w 19.60 39.33 0 0 0 0 U2 2 glazing, cir Iw 0.650 w 0.00 0.00 0 0 0 0 11DO 0.390 w 10.92 10.34 0 0 a _ o c _ 16B30ad 0.032 - 0.90 _ 1.60 0 0 0 0 _ F 22A4ph 1 1.358 - 38.02 0.00 168 26 9w 0 6 c)AED excursion -145 Envelope losstgain 2638 1738 12 a) Infiltration 383 90 b) Roomventilation 0 0 13 Internal gains: Occupants( 230 0 0 Applianceslother 0 Subtotal (lines 6to 13) 3021 1828 Less oWeral load 0 0 Less transfer 0 a Redistribution 0 0 14 Subtotal 3021 1828 15 Duct loads 19% 18Yo 565 329 Toroom load 35M 2157 Air required (rim) 151 99 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigft s t- 2018-Nov-0610:22:44 RightSuite® Universal 2018 18.0.31 RSL08101 Page 4 EADobumnets\Wrightsoft FNACIPOLK RESIDENCE mp Colo = MJ8 Front Door faces: W UTA W N Ol +m NAWN+ P� WOW 3 m Z—M � S Tn ar 3333 j.3.. _on _ 2- a gm 0 n 3 0 8 @ o m @ �L'��v 3 01 NN+NN+NNNN+N NN+ N t00 N e N' �_���_� >•a 3a j > > a'3� g3t3�3�3g3 yff mR =m '�N yy-�yo00p py�pp gog QpQ�pq+�pp gpQ Qp�ipppgg Pm ifd KS Y42S HiSf�H7f52S 2YHH Gf i9 HHXf ��FFFFmmmmmmmmo�ov � m x ' op+oi�o+tup�o ���w +i�pop o+ - y pop pop H O H V H W AH Olv r O O W� 0 HW O O�OlVl�O ty NO�JN OIOONN 00� �^ o O � y o�000��ofio 000�aoo� v �Px OC VA OOO W 0"111 1OtOO OVA Omb�000�m10001 �� vd an O pf (�jj g Opp WV + _ m� A +J Y 0 W� 00 0 O O N O ONO O O A 0 0 O O+ � a OD fm0 0 oa00000000000a0000 �� b b 0 0 oa0000o000000a0000 x w� ' on = W O 00 p N y 00 oorYoo o0 0+o m di 1000000000000m0000 Li 4 wrightsoft Right-M Worksheet Job: AHU 2 Date: NOV. 6, zole By: QUICK CALCS, INC. 317 ST LUCIE LAKE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUCKCALCS@AOL.COM 1 Room rlame BATH 2 BEDROOM2 2 Egxsed wall 5.0 It 25.0 ft 3 Room height 8.0 it hwVcod 8.0 ft heat/cad 4 Room dimensions 5.0 x 8.0 It 13.0 x 12.0 fl 5 Rcom area 40.0 fY 156.0 fF Ty Construction U-value Or HTM Prey (ft� Load Area (fl2) Load number (Bluh/ft?*F) (Btuhlft) or perimeter (it) (Bluh) or perimeter (it) (Bluh) Heat I Cool Gross WP/S Heat Cool Gross WP/S Heal Cool 6 W 12E-Osw 0.068 in 1.90 1.18 0 0 0 0 0 0 0 0 2 glazing, clr love 0.700 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr lone 0.700 in 0.00 0.00 0 0 0 0 0 0 0 0 2gglazing, clr Iowa 0.650. in 18.20 13.94 1.18 0 40 0 34 0 65 0 40 0 104 0 74 0 141 0 88 11 E--G 12E-0sw 2 glazing, Gr l� 0.068 0.700 a a 1.90 0.00 0.00 0 0 0 0 o a 0 0 2 glazing, cir love 0.700 a 0.00 0.00 0 0 0 0 0 0 0 0 ILL-1(C'' 2 glazing, dr lowe 0.650 a 18.20 28.97 6 0 109 174 0 0 0 0 2 alazinn. clr lowe 0.650 a 18.20 28.97 0 0 0 0 30 0 546 869 w 12E-0sw 0.068 s 1.90 1.18 0 0 0 0 96 55 105 65 2 glazing, cir lowe 0.700 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr lowe 0.650 s 18.20 13.94 0 0 0 0 41 41 743 . 569 W, 12E0sw 0.700 w 1.00 0 0 0 0 0 0 0 0 2 glazing, dr la a 0.690 w 0.00 8.20 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.390 w 10.20 8.97 20.00 0 0 0 0 0 0 0 0 11DO 0.032 w 0.90 0 0 0 0 0 0 0 0 C 0.90 1.60 40 40 36 64 15a 150 740 250 F 22A4phd 22Mph i 1.358 1.358 - 0.00 0.00 0.00 0 0 0 0 0 0 _ 0 0 6 c)AED excursion -21 -135 Envelope loss/gain 210 257 1674 1705 12 a) InfiHratlon 74 17 369 86 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 284 275 2043 1792 Less e#ennal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 110 121 106 116 14 Subtotal 393 396 2149 1908 15 Duct loads 27% 36% 105 142 27Wo 36 /0 574 6&l Total mom load 499 536 2724 2592 Air required(dm) 28 25 154 122 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. :- wrl9hGsoft- 2018-No"610:22:44 A is ft kPOLK REST Universal 2018 18.0.37 RSU06701 Page 6 E:1DocumnetslWdghtsoR HVACIPOLK RESIDENCEmp CaIc=MJB Front Daorfaces: W wrightsoftRi Right-M Worksheet Job: AHU 2 Date: NOV. 6, zote By: QUICK CALCS, INC. 317 ST LUCIE LAZE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name M WIC W/o 2 wed ,well 3.0 ft 0 ft 3 Room height 8.0 ft heat/cod 8.0 ft heaticool 4 Room dimensions 10.0 x 3.0 it 4.0 x 3.0 It 5 Room area, 30.0 fF 12.0 fY Ty Construction U-value Or HTM Area (ft2) Load Prey (ft� Load number (8tuh/ft� °F) I (Btuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat I Cool Gross WPIS Heat Cod Gross WP/S Heat Cool 6 lyV 12E-0sw 0. n .0 . 0 0 0 0 0 0 0 0 �L_CCC 2 glazing, cir lori-e 0.700700 n 0 0 0.00 0.0000 0 0 0 0 0 0 0 0 0 2 glazing, clrlon'-e 0.700 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr Io 0.650 n 18.20 13.94 0 0 0 0 0 0 0 0 11 12E-Om 0.068 a 1.90 1.18 0 0 0 0 0 0 0 0 2 glazing, cir hive 0.700 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.700 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 28.97 0 0 0 0 0 0 0 0 2 glazing, cir lows 0.650 a 18.20 28.97 0 0 0 0 0 0 0 0 W 121-�sw 0.068 s 1.90 - 1.18 24 24 46 28. 0 0 0 0 II--�-.� 2 g Ing, dr Iowe 0.70D s 0.00 0.00 0 0 0 0 0 0 0 0 �--G 2 glazing,cir love 0.650 s 18.20 13.94 0. 0 0 0. 0 0 0 0 W 12E-Osw 0.065 w 1.90 1.18 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.700 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.650 w 1&20 28.97 0 0 0 0 0 0 0 0 11D0 0.390 w 0.00 0.00 0 0 0 0 0 0 0 0 C 1613ZOad 0.032 - 0.90 1.60 30 30 27 48 12 12 11 19 F 22A4ph 1.358 - 0.00 - 0.00 0 0 0 0 0 0 - 0 0 6 o)AED excursion -6 -1 Envelope IoWgain 73 70 11 18 12 a) Infihration 44 10 0 0 b) Rmmventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 a 0 Applianceslother 0 0 Subtotal (lines 6to 13) 117 81 11 18 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -117 -81 -11 -18 14 Subtotal0 0 0 0 15 Duct loads 27% 36% 0 0 27% 361% 0 0 Tdd room load 0 0 0 0 Air required (dm) 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. y{f wrrghisoTi- 2018-Nov-0610:22:44 RigWSutte® Universal 2018 18.0.31 RSU08101 Page 7 E:1Documnots\Wrightsot HVAC\POLKRESIDEI-E.mp Caic=MJ8 Front Doorfaces: W wrightsoft, Right-J® Worksheet Job: AHU 2 Date: NOV. 6, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6798 Email: QUCKCALCS@AOL.COM 1 Room come MASTER BEDROOM M BATH 2 151Qrosed wall 28.0 ft 24.0 ft 3 Room height 8.0 ft hwVcod 8.0 ft heat/mol 4 Rwrn dimensions 14.0 x 14.0 ft 1.0 x 119.0 ft 5 Rcom area 198.0 It. 119.0 ft. TV Constnrtion U-value Or HTM PM (g� Lmd Area (ft� Lout number (StuIvfW'Fj (Btuwn or perimeter )ft) (Btuh) or perimeter (fl) (6tuh) Heal Cool Gross MRS Heat Cool Gnus WP/S Heat Cool 6 lQ/ ILA 12E4]sw 2 glazing, cir loxe 2 glazing, cir Iowa 0.700 0.700 0.700 n n In 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 72 0 0 57 0 0 100 0 0 67 0 0 -EGG 2 glazing,. clr Iowa 0.650 n 18.20 - 13.94 0 0 0 0 15 0 273 209 11 12E-0sw 0.0 a 1.0 1. 0 0 0 0 0 0 0 0 2 glazing, dr lowe 2 glazing, dr Iowa 0.77000 0.0 a a 0.000 0.00 0.0000 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr lovv-e 0.65650 a 18.20 28.97 0 0 0 0 0 0 0 0 W, 2 5-0sw, clr love 12E-0sw 0.650 0.06B a s 11.90 1.00 21.18 L18 0 110 0 71 0 130 0 84, 0 0 - 0 0 0 0 0 I6 W 2glazing, dr lo, a 2 glazing, clr love 72Eblsw 0.700 0.068 0.068 s s w 0.00 11.20 1.90 3.94 13.18 1.18 0 41, 112 0 41 82 0 743. 156- 0 5� 97 0 0 120 0 0 0 90 0 0 171 0 6 106 2 glazing, cr Iowa 2 glazing, dr lox a 0.700 0.650 w w 0.00 18.20 0.00 23.97 0 30 0 0 0 546 0 869 0 30 0 0 0 546 0 869 11d0 0.390 w 0.00 0.00 0 0 0 0 0 _ 0- 0 0 c 16B30ad 0.032 Q90 -1.60 196 196 176 314 119 119 107 190 F 22A4ph I 1.35E - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 24 189 Envelope loss/gain 1756 1957 1206 1631 12 a) Infilhation 413 97 354 83 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants (a1 230 0 0 0 0 Appliames/dher 900 0 Subtotal (fines 6 to q 2169 2954 1559 1714 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 216 289 130 205 14 Subtotal 2385 3243 1690 1919 15 Duct Inds 27Wo 36% 637 1163 27% 3695 452 fi88 Total room lead 3023 4406 2141 2607 Air required (cfm) 177 208 121 123 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -FW IwrrghtsoT!- 2018-Nov-0610:22:44 A "'-- RlghtSuiteO Universal 201818.0.31 RSLI08101 Page E:1DmumnetslWnghtsoft HVAC%POLK RESIDENCE.mp Calc = MJB Front Door laces: W wrightsoft' Right-M Worksheet Job: AHU 2 Date: NOV. 6, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LAKE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOLCOM 1 Room mums, HALLWAY BEDROOM 3 2 3 Exposed wall Room height 5.0 ft 6.0 ft heaVcod 25.0 it 8.0 It heat/cod 4 5 Room dimensions Room areai 1.0 x 141.0 fl 141.0 iP 13.0 x 12.0 it 156.0 f 2 Ty Construction number U-value (Btuh(tMF) Or HTM (8111101) Area (ft) or perimeter (It) Load (Bluh) Area (ft2) or perimeter (it) Load (&uh) Heat Ccol Gross WP/S Heat Cool Gross WP/S Heat Cool 6 11 12E-0sw 2 glazing, dr laws 2 glazing, or lone 2 gglazing, cir lovle 12E-0sw 2 glazing, or lc +e 2 glazing, cir Iowa 2 glazing, cir lovue 2 plazim. dr lowe ,12E-0sw 29 wing, clr low¢ 2 glazing, clr Iowe 12E-0sw 0.068 0.700 0.700 0.650 0.068 0.700 0.700 0.650 0.650 U68 0.700 0.650 0.068 n n n n a a a a a s. s s W 1.90 0.00 0.00 _ 18.20 1.90 0.00 0.00 18.20 18.20 1.90 0.00 1810 1.90 1.18 0.00 0.00 13.94 1.18 0.00 0.00 26.97 28.97 1.18 0.00 13.94 1.18 0 0 0 0 0 0 0 0 0 0 0 0 40 0 0 0 0 0 0 0 0 0 0 0 0 25 0 0 0 0 0 0 0 0 0 0 0 0 48 0 0 0 0 0 0 0 0 0 0 0 0 30 96 0 0 15 104 0 0 0 15 -0 0 0 0 81 0 0 0 89 0 0 0 0 0 0 0 0 154 0 0 273 169 0 0 0 273 0 0 0 0 96 0 0 209 105 0 0 0 435 0 0 0 0 IW I---v II-G -GG W 2 glazing, cir Iowe 2 glazing, cir to r a 11DO 16B-30ad 0.700 0.6m 0.390 0.032 w W w - 0.00 18.20 0.00 0.90 0.00 28.97 0.00 1.60 0 15 0 141 0 0 0 141 0 273 0 125 0 435 0 226 0 0 0 156 0 0 0 156 0 0 0 140 0 0 0 250 C F 22A4ph _ 1.358 - (100 0.00 0 0 _ 0 0 0 0 0 0 6 c)AED excursion ttt -104 Envelope lontgain 447 801 1009 991 12 a) Infiltration 74 17 369 86 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Appliances/other 0 300 Subtotal Qmes 6 to 13) 521 818 1378 1377 Less a temal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -521 -818 110 121 14 Subtotal 0 0 1488 1498 15 Duct loads 279% 361Y. 0 0 279/6 36% 398 537 Trial mom load 0 0 1886 2035 -"'Ed required 0 0 106 96 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. rt}r- wrl9ti�ofR- 2018-Nov0610:22:44 RightSufte® Univemal 201818.0.31 RSW8101 Page ESDooumnetstWnghtsoft HVACIPOLK RESIDENCE.mp Cato = MJB From Doorfaces: W wrighlsofIRight-J®Worksheet Job: AHU 2 Date: NOV. 6, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUCKCALCS@ACL.COM 1 Room name SEARS 2 E)q=ed wall 8.0 ft 3 Room height 8.0 If heal/cool 4 5 Room dimensions Rcomareal 12.0 x 8.0 ft 96.0 fl2 Ty construction U-value Or FiTNI Area (ft') Load Area Load number (Etuwft%*F) or perimeter qt) (etuh) or perimeter Heat Cool Gross WP/S Heat Cool Gross NP/S Heat cool 6 IN FLU -(CC' 12F�Gsw 2 glazing. clr Icne 2 glazing, clr Iowa 0.068 0.700 -0.700 In1.90 In In 0.00 0.00 1.18 0.00 0.00 64 0 0 49 0 0 93 0 0 58 0 0 Vjl 11 2 glazing, clr love 12E-0sw 0.650 0.700 In a 18.20 13.94 15 0 0 0 273 0 209 0 GGGG 2 glazing, Or lc+e 2 glazing, clr Iowa 2 glazing, dr Iowa 0.700 0.650 0.650 a a a 0.00 0.00 8.20 18.20 0.00 0.00 8.97 28.97 0 0 0 0 0 0 0 0 0 0 0 0 W, 2 plazirq, clr luxe 12E-0sw 0.650 0.06E a s 18.20 .. 1.90 28.97 1.18 0 0 0 0 0 0 0 0. V,V 2 glazing, dr laxe 2 glazing, clr lowe 12E-0sw 0.700 0.650 0.06B s s w 0.00 18,20 1.00 0.00 13.94 1.00 0 0 0 0 0 0 0 0 0 0 0 0 ILL-_-.GGp 2 glazing, cIr Io 2 glazing, dr Iowa 0.700 0.390 w w 0A0 10.00 8.97 20.00 0 0 0 0 0 0 0 0 1100 d 0.032 0.032 w 0.90 0.00 1.60 0 96 0 96 0 86 0 150 F F 22A{ph 22A-t 1.358 - 0.00 0.00 0.00 0 0 0 0 6 c)AED excursion 52 Envelope loss/gain 452 368 12 a) Infiltration 118 28 b) Room ventilation 0 0 13 Internal gains: Occupants (a) 230 0 0 Appliancesrother 300 Subtotal Qines 6to 13) 570 696 Less wdernal load 0 0 Less transfer 0 0 Redistribution 87 136 14 Subtotal 657 832 15 Duct loads 2796 36°/ 176 298 Total room load 1 (i33 1 1131 Air required (cfm) 47 53 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,� A&- wr19F+boR- 201&Nov-0610:22:44 . C k ""'"-'^'^"' RightSuite® Universal 201818.0.31 RSW8101 Page 10 EADocumnetslWrlghtsoft HVACIPOLK RESIDENCE-rup Cale =M.S Front Door faces: W WrightsoftDuct System Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone 772466-6799 Fax 772-46"796 Email: QUICKCALCSQAOLCOM Project Information For. POLK RESIDENCE, GEM BUILDERS 5204 CITRUS AVENUE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.50010.500 in H2O 1.000 in/100ft 627 cfm Job: Date: NOV. 6, 2018 9y: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm 233 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH In 772 33 20 1.000 5.0 Ox 0 RtFg 18.0 200.0 st1 DINING ROOM h 3586 151 99 1.000 7.0 Ox 0 RtFg 37.0 160.0 st1 FAMILY ROOM h 2387 101 99 1.000 7.0 Ox 0 RtFg 39.0 180.0 st1 FAMILY ROOM -A h 2387 101 99 1.000 7.0 Ox0 RtFg 32.0 170.0 st1 KITCHEN c 2187 63 100 1.000 7.0 Ox 0 RtFg 27.0 190.0 st1 KITCHEN -A c 2187 63 100 1.000 7.0 Ox 0 RtFg 19.0 200.0 st1 OFFICE h 2738 116 109 1.000 7.0 Ox0 RtFg 1 28.0 205.0 st1 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 Peak AVF 627 627 1.000 798 12.0 0 x 0 RectFbg Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox 0 627 627 0 0 0 0 Ox 0 RtFg �F wrightsoR^ �t1� �—,•-.-. RIghlSuite® universal 2018 18.0.31 RS1A8101 EADoaumnets\Wrightsolt HVACWOLK RESIDENCE rup Colo =MJB Front Door faces: W 2018-Nov-06 10:22:46 Page 1 Wrightsoft Duct System Summary AHU 2 QUICK CALCS, INC. 317 ST LME LANE, FORT PIERCE, FL 34946 Phone: 772-4688799 Fa c T72-46"796 Emil: OUCKCALCS@AOLCOM Project Information For. POLK RESIDENCE, GEM BUILDERS 5204 CITRUS AVENUE, FORT PIERCE, FL External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm 131 Job: Date: NOV. 6, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH i h 499 28 25 1.000 5.0 Ox0 VIFx 12.1 115.0 st2 BEDROOM 3 h 1886 106 96 1.000 7.0 Ox 0 VIFx 15.8 115.0 st3 BEDROOM2 h 2724 154 122 1.000 7.0 Ox0 VIFx 9.1 115.0 st2 MBATH c 2607 121 123 1.000 7.0 Ox0 VIFx 14.9 115.0 st3 MASTER BEDROOM c 2203 85 104 1.000 7.0 Ox 0 VIFx 12.1 115.0 st2 MASTER BEDROOM -A c 2203 85 104 1.000 7.0 Ox 0 VIFx 14.9 115.0 st2 STAIRS c 1131 47 53 1.000 6.0 Ox0 VIFx 1 9.4 115.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 Peak AVF 274 272 1.000 621 9.0 0 x 0 VinIFIx st2 Peak AVF 353 355 1.000 651 10.0 0 x 0 V[nlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 OxO 627 627 0 0 0 0 Ox 0 VIFx wrightsofi• RightSuite® Unrvsrsa12018 18.0.31 RSIA8101 ^w^E:1Documnets\Wrightsoft HUAGWOLK RESIDENCE.rup Colo =MJ8 Front Door faces: W 2018-Nw06 10:22:46 Page 2