NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eov/economy
Sika Corporation
201 Polito Avenue
Lyndhurst, New Jersey 07071
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AM.
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Sikalasfrc RoofPro Systems
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 13.
The submitted documentation was reviewed by Alex Tigera.
C LIs
MIAMI-DADE COUNTY
NOA No.: 15-0113.01
Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 1 of 13
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub -Category: Waterproofing
Material:' Polyurethane
Maximum Design Pressure: -502.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Sika Fleece 120, 48' x 150' Roll Proprietary A non -woven needle -punched polyester fleece which is
140 & 170 capable of stretching within the membrane to accommodate
a high degree of thermal and structural movement.
Sikalastic 621 TC 5 gal. pails ASTM D 6083 A single component, moisture triggered; aliphatic
polyurethane elastomeric coating. Used as a UV stable top
coat which is available in a variety of colors.
Sikalastic 624 WP 5 gal pails, ASTM C 836 • Sikalastic 624 WP is a single component elastomeric
polyurethane liquid applied waterproofing membrane
Reemat Premium 51" x 420' Proprietary A random woven fiberglass reinforcement scrim which is
Roll capable of stretching within the membrane to accommodate
a high degree of thermal and structural movement.
Sikalastic DTE Primer 1 gal Proprietary Two -component epoxy primer for damp cementitious
substrates.
Sika Bonding Primer 1 gal Proprietary Two -component water based primer.
Sika Drainage Mat 720 4' x 50' Proprietary Prefabricated polypropylene and woven filter fabric
drainage mat.
NOA No.: 15-0113.01
MIAMI-DAD' COUNTY Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 2 of 13
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS
TABLE 2
Test Product
Product Dimensions Specification Description Manufacturer
Silica Sand Pre -packaged bags N/A Clean, rounded, oven dried quartz Generic
sand with a minimum size
gradation of 16-30 mesh for
vehicular traffic and 20-40 mesh
for pedestrian traffic, and a
minimum hardness of 6.5 per the
Moh's scale. It should be free of
metallic or other impurities.
The seeding of the aggregate shall
be with an even, light broadcast
short of or just to refusal. Any
loose aggregate must be removed
prior to recoating. Back roll
aggregate where indicated.
MAPEI Ceramic 50 lb. bag ANSI A118.4 Polymer enriched thin set mortar Mapei
Tile Mortar
Versabond Fortified 25 & 50 lb. bag ANSI Al 18.4 Polymer modified thin set mortar Custom Building
Thin Set Mortar Products
Laticrete 254 50 lb. bag ANSI A118.4 Polymer fortified thin set mortar Laticrete
Platinum Mortar International, Inc.
Tile Nominal 12" x 12" ANSI A137.1 Generic
Structural Concrete 2500 psi minimum
MIAMI ADE COUNTY
Concrete overburden
Generic
NOA No.: 15-0113.01
Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 3 of 13
EVIDENCE SUBMITTED:
Test Agencv
Test Identifier
Test
Date
Specification
PRI Construction Materials
LPI-045-02-01
ASTM D 7311
12/04/12
Technologies
LPI-046-02-01
ASTM C 297
10/20/14
LPI-049-02-01
TAS 114 D
10/06/14
LPI-049-02-02
TAS 114 D
10/06/14
LPI-052-02-01
ASTM C 836
12/18/14
LPI-062-02-01
TAS 114 D
02/18/15
Intertek
101892419MID-001a
ASTM E 108
11/19/14
i
COUNTY NOA No.: 15-0113.01
MIAMI•DADE
AD Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 4 of 13
APPROVED APPLICATIONS:
Deck Type 1
Concrete Decks
Deck Description:
Min. 2500psi
System Type F(1):
Sikalastic RoofPro System with Tiles
Substrate
Surface must be clean, dry and sound with an open texture. Remove dust, laitance, grease,
Preparation:
curing compounds, bond inhibiting impregnations, waxes, and any other contaminants. All
projections, rough spots, etc. should be dressed off to achieve a level surface prior to the
application.
All concrete should be cleaned and prepared to achieve a laitance and contaminant free, open
textured surface by blast cleaning or equivalent mechanical means (CSP 3-4 per ICRI
guidelines).
Primer: Apply Sikalastic DTE Primer with a flat squeegee or roller at approximately 200 ftZ/gal and
work well into the substrate to ensure adequate penetration and sealing and puddles are
avoided.Allow Primer to dry tack free. Base Coat must be applied within 72 hours of primer
application.
Or
Apply Sika Bonding Primer with a flat squeegee or roller at approximately 300 ft2/gal. and
work well into the substrate to ensure adequate penetration and sealing and puddles are
avoided. Allow primer to dry tack free. Base coat must be applied within 24 hours of primer
application.
Base Coat: Sikalastic 624 WP should be applied at a min. 45 wet mils (35'ft2/gal.) using a roller or
notched squeegee or trowel and backroll using a phenolic resin core roller. Extend base coat
over entire area including previously detailed cracks and control joints.
Reinforcement: Sika Reemat Premium is embedded into the wet base coat. Allow base coat and
reinforcement to cure until tack free before top coating.
Or
Sika Fleece is embedded in a wet on wet application method. Apply the base coat and lay in
the Sika Fleece. Apply the top coat of the Sikalastic 624 WP to finish saturation of the Sika
Fleece.
Top -Coat Sikalastic 624 WP Reemat Premium reinforced base coat shall receive a top coat after cure
applied at a minimum of 40 mils wet (40 sq.ft./gal.) using a roller or notched squeegee and
backroll using a phenolic resin core roller.
Or
Sikalastic 624 WP Sika Fleece reinforced system shall receive 40 mils wet (40 ftZ/gal)
additional resin applied using a phenolic resin core roller to the wet base coat and Sika Fleece
to achieve full saturation.
NOA No.: 15-0113.01
MIAMIrlg COI NTY Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 5 of 13
Sand -Coat Sikalastic 624 WP should be applied at a min. 15 mils wet (100 ftz/gal) using a roller or
notched squeegee and backroll using a phenolic resin core roller. Apply silica sand evenly
distributed at the rate of 501bs/100sq.ft: into the wet coat. Remove excess sand prior to
topping.
Integrity Vest: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab.
Water maybe maintained for a period longer than 24 hours if required.
Verify that the structure can support the deadload weight of a watertight test before
proceeding. The integrity of the cured membrane on a horizontal surface may be verified by
damming the entire area and flooding with water to a minimum depth of 2" and allowing the
water to stand for 24-48 hours. Visually inspect the bottom surface to check for any water
penetration
Inspection: Contractor and a representative of the membrane manufacturer shall inspect the
waterproofing assembly and notify the contractor of any defects. All defects shall be
corrected.
Topping/ Nominal 12" x 12" tiles complying with ANSI A137.1 attached with Laticrete 254 Platinum
Overburden: thin -set mortar applied with 1/4" x 3/8" x 1/4" notched trowel.
Or
Nominal 12" x 12" tiles complying with ANSI A 37.1 attached with Versabond Fortified
Thin -Set Mortar applied with 1/4" x 3/8" x 1/4" notched trowel.
Or
Nominal 12" x 12" tiles complying with ANSI A137.1 attached with MAPEI Ceramic Tile
Mortar applied with 1/4" x 3/8" x 1/4" notched trowel.
Maximugt Design
Pressure: -495 psf (See General Limitation #9)
NOA No.: 15-0113.01
MIAMI-DADE COUNTY Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 6 of 13
Deck Type 1
Concrete Decks
Deck Description:
Min. 2500 psi
System Type F(2):
Sikalastic RoofPro System, Dual Slab
Substrate
Surface must be clean, dry and sound with an open texture. Remove dust, laitance, grease,
Preparation:
curing compounds, bond inhibiting impregnations, waxes, and any other contaminants. All
projections, rough spots, etc. should be dressed off to achieve a level surface prior to the
application.
All concrete should be cleaned and prepared to achieve a laitance and contaminant free, open
textured surface by blast cleaning or equivalent mechanical means (CSP 34 per ICRI
guidelines).
Primer: Apply Sikalastic DTE Primer with a flat squeegee or roller at approximately 200 fiz/gal and
work well into the substrate to ensure adequate penetration and sealing and puddles are
avoided.Allow Primer to dry tack free. Base Coat must be applied within 72 hours of primer
application.
Or
Apply Sika Bonding Primer with a flat squeegee or roller at approximately 300 ftz/gal. and
work well into the substrate to ensure adequate penetration and sealing and puddles are
avoided. Allow primer to dry tack free. Base coat must be applied within 24 hours of primer
application.
Base Coat: Sikalastic 624 WP should be applied at a min. 45 wet mils (35 ftz/gal.) using a roller or
notched squeegee or trowel and backroll using a phenolic resin core roller.. Extend base coat
over entire area including previously detailed cracks and control joints.
Reinforcement: Sika Reemat Premium is embedded into the wet base coat. Allow base coat and
reinforcement to cure until tack free before top coating.
Or
Sika Fleece is embedded in a wet on wet application method. Apply the base coat and lay in
the Sika Fleece. Apply the top coat of the Sikalastic 624 WP to finish saturation of the Sika
Fleece.
Top -Coat Sikalastic 624 WP Reemat Premium reinforced base coat shall receive a top coat after cure
applied at a minimum of 40 mils wet (40 sq.ft./gal.) using a roller or notched squeegee and
backroll using a phenolic resin core roller.
Or
Sikalastic 624 WP Sika Fleece reinforced system shall receive 40 mils wet (40 ftz/gal)
additional resin applied using a phenolic resin core roller to the wet base coat and Sika Fleece
to achieve full saturation.
NOA No.: 15-0113.01
MIAMI•DADE COUNTY Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 7 of 13
Sand -Coat Sikalastic 624 WP should be applied at a min. 15 mils wet (100 ft2/gal) using a roller or
notched squeegee and backroll using a phenolic resin core roller. Apply silica sand evenly,
distributed at the rate of 50lbs/100sq.ft: into the wet coat. Remove excess sand prior to
topping.
Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab.
Water maybe maintained for a period longer than 24 hours if required.
Verify that the structure can support the deadload weight of a watertight test before
proceeding. The integrity of the cured membrane on a horizontal surface may be verified by
damming the entire area and flooding with water to a minimum depth of 2" and allowing the
water to stand for 24-48 hours. Visually inspect the bottom surface to check for any water
penetration.
Inspection: Contractor and representative of the membrane manufacturer shall inspect the
waterproofing assembly and notify the contractor of any defects. All defects shall be
corrected.
Topping/ Structual Concrete Topping, minimum 2500 psi, with a minimum 2" thickness in accordance
Overburden: with applicable building code.
Maximum Design
Pressure: N/A
NOA No.: 15-0113.01
MIAMI DADE COUNTY Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 8 of 13
Deck Type 1
Concrete Decks
Deck Description:
Min. 2500 psi
System Type F(3):
Sikalastic RoofPro System
Substrate
Surface must be clean, dry and sound with an open texture. Remove dust, laitance, grease,
Preparation:
curing compounds, bond inhibiting impregnations, waxes, and any other contaminants. All
projections, rough spots, etc. should be dressed off to achieve a level surface prior to the
application.
All concrete should be cleaned and prepared to achieve a laitance and contaminant free, open
textured surface by blast cleaning or equivalent mechanical means (CSP 34 per ICRI
guidelines).
Primer: Apply Sikalastic DTE Primer with a flat squeegee or a roller at approximately 200 sq. ft. /gal
and work well into the substrate to ensure adequate penetration and sealing and puddles are
avoided.Allow Primer to dry tack free. Base Coat must be applied within 72 hours of primer
application.
Or
Apply Sika Bonding Primer with a flat squeegee or roller at approximately 300 ft2/gal. and
work well into the substrate to ensure adequate penetration and sealing and puddles are
avoided. Allow primer to dry tack free. Base coat must be applied within 24 hours of primer
application.
Base Coat: Sikalastic 621 TC should be applied at a min. 45 wet mils (35ft2/gal.) using a roller or
notched squeegee or trowel and backroll using a phenolic resin core roller. Extend base coat
over entire area including previously detailed cracks and control joints.
Reinforcement: Sika Reemat Premium is embedded into the wet base coat. Allow base coat and
reinforcement to cure until tack free before top coating.
Top -Coat Sikalastic 621 TC should be applied at a min. of 30 mils wet (53 ft2/gal.) using a roller or
notched squeegee and backroll using a phenolic resin core roller.
Non -Skid! Coat: Sikalastic 621 TC should be applied at a min.15 mils wet (100 ft2/gal) using a roller or
notched squeegee and backroll using a phenolic resinn core roller. Apply silica sand evenly
distributed broadcast at a rate of 2.75 lbs/100 ft2 into the wet non skid coat and backroll to
embed sand. Allow coating to cure a minimum of 16 hours at 70°F and 50% RH or until tack
free between coats, and a minimum of 72 hours before opening to pederstrian traffic.
NOA No.: 15-0113.01
MIAMI•DADE COUNTY Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 9 of 13
Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab.
Water maybe maintained for a period longer than 24 hours if required.
Verify that the structure can support the deadload weight of a watertight test before
proceeding. The integrity of the cured membrane on a horizontal surface may be verified by
damming the entire area and flooding with water to a minimum depth of 2" and allowing the
water to stand for 2448 hours. Visually inspect the bottom surface to check for any water
penetration.
Inspection: Contractor and a representative of the membrane manufacturer shall inspect the
waterproofing assembly and notify the contractor of any defects. All defects shall be
corrected.
Maximum Design
Pressure:) -502.5 psf (See General Limitation #9)
NOA No.: 15-0113.01
MIAMI•DADE COUNTY Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 10 of 13
Deck Type 1
Concrete Decks
Deck Description:
Min. 2500 psi
System Type F(4):
Sikalastic RoofPro System, Planters
Substrate
Surface must be clean, dry and sound with an open texture. Remove dust, laitance, grease,
Preparation:
curing compounds, bond inhibiting impregnations, waxes, and any other contaminants. All
projections, rough spots, etc. should be dressed off to achieve a level surface prior to the
application.
All concrete should be cleaned and prepared to achieve a laitance and contaminant free, open
textured surface by blast cleaning or equivalent mechanical means (CSP 3-4 per ICRI
guidelines).
Primer: Apply Sikalastic DTE Primer with a flat squeegee or roller at approximately 200 ftz/gal and
work well into the substrate to ensure adequate penetration and sealing and puddles are
avoided.Allow Primer to dry tack free. Base Coat must be applied within 72 hours of primer
application.
Or
Apply Sika Bonding Primer with a flat squeegee or roller at approximately 300 ft2/gal. and
work well into the substrate to ensure adequate penetration and sealing and puddles are
avoided. Allow primer to dry tack free. Base coat must be applied within 24 hours of primer
application:
Base Coat: Sikalastic 624 WP should be applied at a min. 45 wet mils (35 ftZ/gal.) using a roller or
notched squeegee or trowel and backroll using a phenolic resin core roller. Extend base coat
over entire area including previously detailed cracks and control joints.
Reinforcement: Sika Reemat Premium is embedded into the wet base coat. Allow base coat and
reinforcement to cure until tack free before top coating.
Or
Sika Fleece is embedded in a wet on wet application method. Apply the base coat and lay in
the Sika Fleece. Apply the top coat of the Sikalastic 624 WP to finish saturation of the Sika
Fleece.
Top -Coat Sikalastic 624 WP Reemat Premium reinforced base coat shall receive a top coat after cure
applied at a minimum of 40 mils wet (40 sq.ft./gal.) using a roller or notched squeegee and
backroll using a phenolic resin core roller.
Or
Sikalastic 624 WP Sika Fleece reinforced system shall receive 40 mils wet (40 ftZ/gal)
additional resin applied using a phenolic resin core roller to the wet base coat and Sika Fleece
to achieve full saturation.
NOA No.: 15-0113.01
MIAMIUNTY •DADECOY Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 11 of 13
Integrity Test: Required, and shall be performed in accordance with ASTM D 5957 by an approved lab.
Water maybe maintained for a period longer than 24 hours if required.
Verify that the structure can support the deadload weight of a watertight test before
proceeding. The integrity of the cured membrane on a horizontal surface may be verified by
damming the entire area and flooding with water to a minimum depth of 2" and allowing the
water to stand for 24.48 hours. Visually inspect the bottom surface to check for any water
penetration.
Inspection: Contractor and a representative of the membrane manufacturer shall inspect the
waterproofing assembly and notify the contractor of any defects. All defects shall be
corrected.
Drainage Layer: Sika Drainage Mat 720 loose laid over top coat.
Surfacing: Backfill the planter with soil medium.
Maximum Design
Pressure: -502.5 psf (See General Limitation #9)
NOA No.: 15-0113.01
MIAMI•DADE COUNTY-M Expiration Date: 07/09/20
Approval Date: 07/09/15
Page 12 of 13
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Required integrity flood testing report shall be provided to the Building Official for review at time of final
inspection.
3. All work shall be performed by a Contractor licensed to do roofing/waterproofing and be an applicator trained
by Sika Corporation. Sika Corporation shall supply a list of approved applicators to the authority having
jurisdiction.
4. Flashings shall be installed according to the manufacturers published standard details, specific details, approved
by Sika Corporation and shall be submitted to the Building Official for review.
5. Contractor shall submit to the Building Official for review the system specifications and details. Submission of
these documents, as well as the proper application and installation of all materials shall be the sole
responsibility of the contractor.
6. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform
with Roofing Application Standard RAS 111 and the wind load requirements of applicable Building Code.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General Limitation #9 will not be applicable.)
8. A non-skid surfacing is required for all pedestrian areas, plaza decks or balconies.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening
at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is
specifically referred within this NOA, General Limitation #7 will not be applicable.)
10 All: products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
11. Sikalastic shall not be installed over lightweight insulating concrete.
12. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the imprint or
identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product
Control Approved" or the Miami -Dade County Product Control Seal as shown below
MIAMI-DADS COUNTY
-W. 1
END OF THIS ACCEPTANCE
NOA No.: 15-0113.01
MIAMI-DADE COUNTY Expiration Date: 07/09/20
Approval Date: 07/09/15