Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REVISIONS - BUILDING PERMIT
^I LE COPY OFFICE USE ONLY: DATE FILED: 01.23.2019 REVISION FEE: _ S-00 LOCATION/SITE ADDRESS: 5204 Citrus Avenue PERMIT # 1812-0181 RECEIPT # 144 1 oe)L. PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION SCANNED 2300 VIRGINIA AVENUE BY FORT PIERCE, FL 34982.5652 (772)462.1553 St. Lucie County APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION Fort Pierce, FL 34982 DETAILED DESCRIPTION OF PROJECT REVISIONS: Initial plan shows 4 single doors on upper south -side balcony but request to change to 2 sets of double French style doors CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: _ BUSINESS NAME: QUALIFIERS NAME: owner ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): OWNER/BUILDER INFORMATION: ST. LUCIE CO CERT. #: NAME: Steve Polk and/or Camille Polk ADDRESS: 276 NE Summer Rd CITY: Port St Lucie STATE: FL ZIP: 34983 PHONE (DAYTIME: 214-693-8600 FAQ{: ARCHITECT/ENGINEER INFORMATION: NAME: Summit Design & Forensics ADDRESS: 725 BE Port St Lucie Blvd CITY: Port St Lucie PHONE (DAYTIME): 772-285-0572 STATE: FL Iye l � '/ I/ I , t a r•, ,,q ZIP: 34984 existing top plate sp6 16"c.c.— (6) 10d nails (3) 2 x 12 header bond together with 16d at 6"c.c. use plywood fillers as required sp6 16"c.c.— (6) 10d nails Mbt1 PLAN-,?PIJ ALL PROPOSED WORK ARESUDJEC �:ANYCORRECTIONS REQUIRED 64rr.LA INSPECTORS THAT MAY BE NECESSARY IN ORDER TO MMPLY WITH ALL APPLICABLE CODES. oo''i FaR Nry� sp6 at every2�,� with (6) 10d nc top& sole plate [y CAp (2) msta18 l�f 60N� (14) 10d nails FAjg06 OF NOTE: Shore existing structure. Remove post & existing header & install new header as shown. new (2) 2 x 6 studs Second Floor Balcony Brng. Header Detail At French Doors NOT TO SCALE DATE CAMILE POLK SK DESIGNED U1-16-2019 aHw DKAwN 5204 S. CITRUS AVE GMW 0` 14201 CHKKEO WHITE CITY, FL 34982 aF) CH 30B NO. 2nd FLOOR BALCONY 2018-094 BEARING HEADER DETAIL OF !�ATE �FS N PE FL PE SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 OFFICE USE ONLY: I /�/ I DATE FII ED: 5 ' . oL�1/ ( / # so / REVISION FEE: Z RECEIPT # 161 qlr PLANNING & DEVELOPMENT BUILDING & CODE REGULATION 2300 VIRGINIA AVEP FORT PIERCE, FL 3496 V72) 462.1553 APPLICATION FOR BUILDING PROJECT INFORMATII LOCATION/SITE ADDRESS: '5jx DETAILED DESCRIPTION OF PROJECT REVISIONS: 9' 1 I, /! 11 I S h I nil 0h CWAPPEb CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: OWNEWBUH.DER INFORMATIH NAME: C'AM_>LLI�_ CITY: /y /-- PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130117 TE: STATE: ST. LUCIE CO CERT. #: FAX: FAX: rnx: ZIP: ZIP: ZIP: IsW-VIX1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: POLK RESIDENCE Builder Name: GEM BUILDERS Street: 5204 CITRUS AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner. CAMILLE POLK Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort. Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or epsting New (From Plans) 9. Wall Types (2016.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 1968.00 ft' b. Frame - Wood, Adjacent R=11.0 48.00 ft2 3. Number of units, If multiple family 1 c. WA R= n= 4. Number of Bedrooms 3 d. N/A R= ryz 10. Ceiling Types (1932.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1932.00 ft' 6. Conditioned floor area above grade (ft2) 1932 b. N/A R= ft2 c. N/A R= ft- Conditioned floor area below grade (112) 0 11. Ducts R ft2 7. Windows (484.0 sqk.) Description Area a Sup: Attic, Ret: Attic, AH: Attic 6 125 a U-Factor. Dbl, U=0.65 251.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: SHGC=0.20 b. U-Factor: Dbl, U=0.70 233.00 ft- 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a Central Unit 18.8 SEER:16.00 b. Central Unit 18.8 SEER:16.00 c. U-Factor- WA ft- SHGC: 13. Heating systems katuthr Efficiency d. U-Factor: N/A ft2 a Electric Strip Heat 17.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 2.905 ft. Area Weighted Average SHGC: 0.248 14. Hot water systems a Electric Cap: 40 gallons 8. Floor Types (1932.0 sqft.) Insulation Area EF: 0.980 a Raised Floor R=30.0 970.00 tt= b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 962.00 ft= None c. N/A R= fls 15. Credits None Glass/Floor Area: 0.251 Total Proposed Modified Loads: 59.57 PASS Total Baseline Loads: 65.01 I hereby certify that the plans and specifications covered by Review of the plans and by this C�SKg St this calculation are in compliance with the Florida Energy specifications covered Code. calculation indicates compliance �n with the Florida Energy Code. PREPAR DATE: 9 Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that IN building, as de igne , is in compliance Florida Statutes., with the Florida Ener y Code, f -CCD WME OWNER/A ENT, ` ' BUILDING OFFICIAL: DATE: 1A DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNETflCC 380, Is not greater than 0.030 On for whole house. 5/8/2019 9:24 AM EnergyGaugeti) USA Section R405.4.1 Compliant Software Page 1 of 7 rnonn onnr:_OM7 IRIPI IT CI IMMARV CHFCKI IST REPORT PROJECT Title: POLK RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1932 Lot # Owner Name: CAMILLE POLK Total Stories: 2 BlocktSubdivision: # of Units: 1 Worst Case: No PIffiBook: Builder Name: GEM BUILDERS Rotate Angle: 0 Street: 5204 CITRUS AVENUE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Ebsting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 2 970 7760 2 AHU 1 962 7696 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 KITCHEN 240 1920 Yes 0 1 Yes Yes Yes 2 BATH 56 448 No 0 1 Yes Yes Yes 3 OFFICE 117 936 No 0 1 Yes Yes Yes 4 HALL 24 192 No 0 1 No Yes Yes 5 FAMILY ROOM 357 2856 No 0 1 Yes Yes Yes 6 DINING ROOM 168 1344 No 0 1 Yes Yes Yes 7 WIC3 24 192 No 0 1 Yes Yes Yes 8 BATH 2 40 320 No 0 1 Yes Yes Yes 9 BEDROOM2 156 1248 No 0 1 ,1 Yes Yes Yes 10 M WIC 30 240 No 0 1 Yes Yes Yes 11 W/D 12 96 No 0 1 No Yes Yes 12 MASTER BEDROO 196 1568 No 0 1 1 Yes Yes Yes 13 M BATH 119 952 No 0 1 Yes Yes Yes 14 HALLWAY 141 1128 No 0 1 Yes Yes Yes 15 BEDROOM 3 156 1248 No 0 1 1 Yes Yes Yes 16 STAIRS 96 768 No 0 1 Yes Yes Yes 5/8/2019 9:24 AM EnergyGauge(g) USA Section R405.4.1 Compliant Software Page 2 of 7 onone oenG_on17 INPI IT C1IMMARV CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHEN 26 ft 0 240 ftz __-- 1 0 0 2 Slab -On -Grade Edge Insulation BATH 8 it 0 56 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulation OFFICE 22 ft 0 117 112 ____ 1 0 0 4 Slab -On -Grade Edge Insulation HALL 1 It 0 24 ft2 _--- 1 0 0 5 Slab -On -Grade Edge Insulation FAMILY ROOM 38ft 0 357 ft2 __-- 1 0 0 6 Slab -On -Grade Edge Insulation DINING ROOM 2611 0 168 ft2 -___ 1 0 0 7 Raised Floor WIC 3 ---- ---- 24 ft2 30 1 0 0 8 Raised Floor BATH 2 ---- ---_ 40 ft2 30 1 0 0 9 Raised Floor BEDROOM2 --__ _--_ 156 ft2 30 1 0 0 i ORaised Floor M W IC ---- __-_ 30 f? 30 1 0 0 11Raised Floor W/D ____ ---- 12 ft2 30 1 0 0 12Rsised Floor MASTER BEDRO _-__ ---- 196 ft2 30 1 0 0 13Ra1sed Floor M BATH __-_ ---- 1 19ft2 30 1 0 0 14Raised Floor HALLWAY ____ ---_ 141 ft2 30 1 0 0 1,-Raised Floor BEDROOM 3 ---- ---_ 156 ft2 30 1 0 0 16Raised Floor STAIRS ---- __-_ 96 ft2 30 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch J # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) i Hip Composition shingles 2161 ft2 0 ft2 Medium 0.3 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area FIBS IRCC , 1 Full attic Unvented 0 1932 ft- N N 5/8/2019 9:24 AM EnergyGauge® USA Section R405.4.1 Compliant Software . Page 3 of 7 vnone oene nn17 mom IT CI IllnnnARV RHFCKI IST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Unvented) KITCHEN 20 Blown 240 ft2 0.1 Wood _ 2 Under Attic(Unvented) BATH 20 Blown 56 ft2 0.1 Wood _ 3 Under Attic (Unvented) OFFICE 20 Blown 117 ft2 0.1 Wood 4 Under Attic (Unvented) HALL 20 Blown 24 1112 0.1 Wood _ 5 Under Attic (Unvented) FAMILY ROOM 20 Blown 357 ft2 0.1 Wood 6 Under Attic (Unvented) DINING ROOM 20 Blown 168 IF 0.1 Wood _ 7 Under Attic (Unvented) WIC 3 20 Blown 24 ft2 0.1 Wood _ 8 Under Attic (Unvented) BATH 2 20 Blown 40 ft2 0.1 Wood _ 9 Under Attic (Unvented) BEDROOM2 20 Blown 156 fI2 0.1 Wood _ 10 Under Attic (Unvented) M W IC 20 Blown 30 ft2 0.1 Wood _ 11 Under Attic (Unvented) W/D 20 Blown 12 ft2 0.1 Wood 12 Under Attic (Unvented) MASTER BEDRO 20 Blown 196 ft2 0.1 Wood _ 13 Under Attic (Unvented) M BATH 20 Blown 119 fI2 0.1 Wood 14 Under Attic (Unvented) HALLWAY 20 Blown 141 ft2 0.1 Wood _ 15 Under Attic (Unvented) BEDROOM 3 20 Blown 156 ft2 0.1 Wood 16 Under Attic (Unvented) STAIRS 20 Blown 96 ft2 0.1 Wood WALLS Adjacent Ca* Width Height Sheathing Framing Solar Below Spare 1 N Exterior Frame - Wood KITCHEN 19 8 0 8 0 64.0 ft2 0 0.3 0.1 0 _ 2 E Exterior Frame - Wood KITCHEN 19 18 0 8 0 144.O ft2 0 0.3 0.1 0 _ 3 E Garage Frame - Wood KITCHEN 11 2 0 8 0 16.O ft2 0 0.3 0.1 0 _ 4 N Garage Frame - Wood KITCHEN 11 4 0 8 0 32.0 ft2 0 0.3 0.1 0 5 N Exterior Frame - Wood BATH 19 8 0 8 0 64.0 f12 0 0.3 0.1 0 6 N Exterior Frame - Wood OFFICE 19 9 0 8 0 72.0 ft2 0 0.3 0.1 0 _ 7 W Exterior Frame - Wood OFFICE 19 13 0 8 0 104.O ft2 0 0.3 0.1 0 _ 8 S Exterior Frame -Wood FAMILY ROO 19 17 0 8 0 136.O ft2 0 0.3 0.1 0 _ 9 W Exterior Frame -Wood FAMILY ROO 19 21 0 8 0 168.O ft2 0 0.3 0.1 0 10 E Exterior Frame - Wood DINING ROO, 19 14 0 8 0 112.0 ft2 0 0.3 0.1 0 11 S Exterior Frame - Wood DINING ROO 19 12 0 8 0 96.0 ft2 0 0.3 0.1 0 _ 12 E Exterior Frame - Wood WIC 3 19 3 0 8 0 24.0 f12 0 0.3 0.1 0 _ 13 E Exterior Frame - Wood BATH 2 19 5 0 8 0 40.0 f12 0 0.3 0.1 0 _ 14 E Exterior Frame - Wood BEDROOM2 19 13 0 8 0 104.0 ft2 0 0.3 0.1 0 15 S Exterior Frame -Wood BEDROOM2 19 12 0 8 0 96.0 f12 0 0.3 0.1 0 _ 16 S Exterior Frame - Wood M W IC 19 3 0 8 0 24.0 ft2 0 0.3 0.1 0 _ 17 S Exterior Frame - Wood MASTER BE 19 14 0 8 0 112.0 ft2 0 0.3 0.1 0 18 W Exterior Frame - Wood MASTER BE 19 14 0 8 0 112.0 ft2 0 0.3 0.1 0 19 N Exterior Frame -Wood M BATH 19 9 0 8 0 72.0 ft2 0 0.3 0.1 0 _ 20 W Exterior Frame - Wood M BATH 19 15 0 e 0 120.0 ft2 0 0.3 0.1 0 21 W Exterior Frame -Wood HALLWAY 19 5 0 8 0 40.0 ft2 0 0.3 0.1 0 22 N Exterior Frame -Wood BEDROOM 3 19 12 0 8 0 96.0 f12 0 0.3 0.1 0 23 E Exterior Frame - Wood BEDROOM3 19 13 0 8 0 104.0 ft2 0 0.3 0.1 0 24 N Exterior Frame -Wood STAIRS 19 8 0 8 0 64.0 ft2 0 0.3 0A 0 5/8/2019 9:24 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 7 wail v # Omt ID Frame Panes _ 1 N 1 Metal Low-E Double 2 E 2 Metal Low-E Double _ 3 E 2 Metal Low-E Double 4 N 5 Metal Low-E Double _ 5 N 6 Metal Low-E Double _ 6 W 7 Metal Low-E Double 7 S 8 Metal Low-E Double _ 8 W 9 Metal Low-E Double _ 9 E 10 Metal Low-E Double _ 10 S 11 Metal Low-E Double 11 E 13 Vinyl Low-E Double 12 E 14 Vinyl Low-E Double _ 13 S 15 Vinyl Low-E Double 14 S 17 Vinyl Low-E Double _ 15 W 18 Vinyl Low-E Double _ 16 N 19 Vinyl Low-E Double _ 17 W 20 Vinyl Low-E Double _ 18 W 21 Vinyl Low-E Double _ 19 N 22 Vinyl Low-E Double 20 E 23 Vinyl Low-E Double 21 N 24 Vinyl Low-E Double Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes WINDOWS Factor SHGC 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.7 0.3 0.65 0.2 0.65 0.2 0.65 0.2 0.65 0.2 0.65 0.2 0.65 0.2 0.65 0.2 0.65 0.2 0.65 0.2 0.65 0.2 0.65 0.2 GARAGE Overhang Tip Area Depth Separatic Y 15.0 ft2 1It6 in 1ft4in Y 12.0 ft2 1ft6in 1It4in Y 15.0 ft- 1It6in 1ft4in Y 6.0 ft2 1It6in 1ft4in Y 15.0 IF 1h6in 1ft4in Y 30.0 ft' 1It6 in 1It4in Y 40.0 ft' 10ft0in 1ft4In Y 30.0 ft2 1 It 6 in I It 4 in Y 30.0 ft2 1 It 6 in 1 It 4 in Y 40.0 IF 10It0 in 104in Y 6.0 IF 1 it 6 in 1 1t 4 in Y 30.0 ft2 1ft6in 1ft4in Y 40.0 IF 1 It 6 in 1 It 4 in Y 40.0 its 1 ft 6 In 1 it 4 in Y 30.0 ft2 1ft6in tft4In Y 15.0 ft2 1It6in tft4in Y 30.0 ftz 1It6in tft4In Y 15.0 IF 1 It 6 in 1 It 4 in Y 15.0 ft' 1It6in tft4in Y 15.0 ft2 1ft6in 1ft4in Y 15.0 1? 1ft 6in 1ft 4In Int Shade Screening None None None None None None None None None None None None Drapes/blinds Exterior None None None None Drapes/blinds Exterior 5 None None None None None None None None None None None None None None None None None None None None None None # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 IF 6 It 8 It 11 INFIL # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1803.2 98.99 186.17 .3174 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts _ 1 Electric Strip Heat( None C0P:1 17 kBtu/hr 2 sys#1 2 Electric Strip Heat( None C0P:1 17 kBtu/hr 1 sys#2 5/8/2019 9:24 AM EnergyGauge6) USA Section 8405.4.1 Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM If System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit( Split SEER: 16 18.8 kBtu/hr 564 cfm 0.8 2 sys#1 2 Central Until Split SEER: 16 18.8 kBtu/hr 564 cfm 0.8 1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft- DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # J # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool _ 1 Attic 6 125 fF Attic 13 fP Prop. Leak Free Attic --- cfm 28.9 cfm 0.03 0.50 1 1 2 Attic 6 125 flz Attic 13 ft2 Prop. Leak Free Attic --- cfm 29.1 cfm 0.03 0.50 2 2 TEMPERATURES Programable Thermostat::: N Fans: CMar Heat ng frX'1 Mar Aprrreiling f ] �X� Jun Jul [ ] [X] AugAu9 ] lxl Sep Oct rf Nov Nov Dec rDO, Dees Venting [ ] Jan [ ] Feb [X] Apr EX] (� May Jun 1 Jul [ 1] Aug l 1 Sep [ [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 5/8/2019 9:24 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space DefauB(8 lbs/sq.ft. 0 W 0 ft 0.3 ELEVATOR LOBBY Default(81bs/sq.ft. ft2 ft 0.3 ELEVATOR Default(8 lbs/sq.ft. ft2 it 0.3 STORAGE Default(81bs/sq.ft. ft. it 0.3 MECH STORAGE Default(81bs/sq.ft. ft2 it 0.3 BATH 1 Default(81bs/sq.ft. ft2 It 0.3 HALL Defauh(81bs/sq.ft. ft2 It 0.3 WIC 1 Defaull(81bs/sq.ft. ft2 It 0.3 AC CHASE Default(8 lbs/sq.ft. ft2 It 0.3 BAR Default(81bs/sq.ft. ft2 It 0.3 CLUB ROOM Default(8 lbs/sq.ft. ft2 It 0.3 POWDER Default(8 lbs/sq.ft. it- ft 0.3 LIVING ROOM Defauk(8 lbs/sq.ft. ft2 It 0.3 KITCHEN DefauB(81bs/sq.ft. 112 ft 0.3 ELEV 2ND FLR Default(B Ibs/sq.ft. ft2 ft 0.3 OPEN Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 1 Defauh(8 lbs/sq.ft. ft2 ft 0.3 ELEV. 3RD FLR DefauB(8 Ibs/sq.ft. ft2 ft 0.3 M W IC Default(81bs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 M HALL Default(81bs/sq.ft. f12 ft 0.3 LOUNGE AREA Default(8 lbs/sq.ft. ft2 ft 0.3 M TOILET Default(8 lbs/sq.ft. ft2 it 0.3 M BATH Default(81bs/sq.ft. ft2 it 0.3 BATH 3 Defmh(B lbs/sq.ft. ft2 it 0.3 LAUNDRY Defauh(8 lbs/sq.ft. IF ft 0.3 BEDROOM 3 Defauk(81bs/sq.ft. ft2 ft 0.3 BEDROOM 2 DefauH(8 lbs/sq.ft. ft2 ft 0.3 W IC 3 DefauB(8 Ilbs/sq.ft. ft2 ft 0.3 MECHANICAL RM Default(8 lbs/sq.ft. 112 It 0.3 HALLWAY Default(8 lbs/sq.ft. ft2 ft 0.3 WIC2 Defauft(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 lbs/s.ft. ft2 ft 0.3 STAIRS 3RD FLR Name: Rating Compant: Signature: Date: 5/8/2019 9:24 AM EnergyGmge® USA Section R405.4.1 Compliant Software Page 7 of 7 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6 0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 37.6 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1932 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.674 b) Solar Heat Gain Coefficient (SHGC) 71b. 0.248 c) Area 7c. 484.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 30.0 So. 10A1. 19.0 10A2. 10B1. 11.0 10B2. 11a. 20.0 11 b. 11 c. 11d. No 14. Heating system: Capacity 34.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0M b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRecl/ g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be c plated based on iyft1le (/rerode compliant features. Builder Signature: t Date: / 'V Address of New Home: 5204 CITRUS AVENUE City/FL Zip: FORT PIERCE FL 5/8/2019 9:24:46 AM EnergyGaugc@ USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. I�1).0(P 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: POLK RESIDENCE Builder Name: GEMBUILDERS Street: 5204 CITRUS AVENUE Permft Office: STLUCIECOUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: CAMILLE POLK Jurisdiction: ST LUCIE COUNTY w x Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be sealed. shall be Insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per Inch minimum. 'Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing. members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with a Where provided Instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall,be filled by Insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring plumbing in exterior wells, or insulation that on installation readily conforms to available space shall extend behind piping and wirin Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be Installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or cellin s. a. In addition, inspection of log walls shall be in accordance win me provisions or iw-vuu. 5/8/2019 9:24 AM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. R wrightsofto Project Summary AHU1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fa1c 772466-6796 Email: OUICKCALCS®AOL.COM Proffiect Information For: 5204 CITRUS AVENUE, FORT PIERCE, FL Notes: V'FCE1VED MAY 0 9 2019 permitting Job: ly Date: MAY 8, 2019 By: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12510 Btuh Structure 11581 Btuh Ducts 2340 Btuh Ducts 2085 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14851 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12983 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2550 Btuh Ducts 932 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 96g 962 Equipment latent load 3482 Btuh Volume (ft3) 7696 7696 Airchangesthour 0.45 0.20 Equipment Total Load (Sen+Lat) 16465 Btuh Equiv. AVF (cfm) 58 25 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AH R I ref 7567539 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 4.4 kW Sensible cooling 13160 Btuh Heating output 14856 Btuh Latent cooling 5640 Btuh Temperature rise 22 OF Total cooling 18800 Btuh Actual air flow 627 cfm Actual air flow 627 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1:00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. w_rlfehlsof!' 2019-May-08 09:20:47 Right -Suite® Universal 201818.0.31 RSW8101 Page 1 '�� EADocumnets\Wrightsolt WAC\POLK RESIDENCE.rup Calc = MJ8 Front Door faces: W + wrightsofte Project Summary AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: OUICKCALCS®AOL.COM Project• • For: LK RESIDENCE GEM BUILDERS 5204 CITRUS AVENUE, FORT PIERCE, FL Notes: Job: Date: MAY 8, 2019 By: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 8763 Btuh Structure 10170 Btuh Ducts 2342 Btuh Ducts 3513 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 11104 Btuh Use manufacturer's data In Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12999 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2502 Btuh Ducts 931 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft2) 970 970 Equipment latent load 3434 Stuh Volume (ft3) 7760 7760 Air changesrhour 0.47 0.20 Equipment Total Load (Sen+Lat) 16433 Btuh Equiv. AVF (cfm) 60 26 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567539 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 2.9 kW Sensible cooling 13160 Btuh Heating output 9846 Btuh Latent cooling 5640 Btuh Temperature rise 14 OF Total cooling 18800 Btuh Actual air flow 627 cfm Actual air flow 627 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c -F1'- wrtghlsoft- 2019-May-0809:20:47 Right-Suite(g) Universal 2018 18.0.31 RSU08101 Page 2 EADocurnnets\Wrightsoft WAMPOLK RESIDENCE.rup Calc = MJ8 Front Door faces: W I wrightsoft Right-J® Worksheet Job: AHU 1 Date: MAY 8, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: OUICKCALCS®AOL.COM 1 2 3 4 5 Room name Elyosed wall Room height Room dimensions Room area AHU 1 120.0 it 8.0 it 962.0 ft- KITCHEN 26.0 it 8.0 It heat/cool 20.0 x 12.0 it 240.0 ft2 Ty Construction number U-value (Btuth/11MF) Or HTM (Btulvft� Area (ftq or perimeter (it) Load (Btuh) Area (ftq or perimeter (it) Load (Btuh) Heat I Cool Gross WP/S Heat I Cool Gross WP/s Heat Cool _-a--_-64 6 11 12E-05w 2 glazing, clr low-e 2 glazing, cir low-s 2 glazing, clr lowe 2 glazing, clrJow;e_ 2 glaiw 2 glazing, clr lowe 2 glazing, clr Iowa 2 glazing, cir low-s 2 gluing, clr lowe 12E-6w 2 glazing clr low-e 2 g g clr low e., '2.glazm 12E-Osw 2 glazing, or low-e 2 glazing, clr low-e 2 glazing, cir low-e 1100 " -0 066 0.700 0.700 0.650 __,__0.650 0.700 0.700 0.700 0.650 0.650 0.068 0.700 0.700 0.068 0.700 0.650 0.550 0.393 n n n n _n- a a a a e s a' s 'mw w w w w 1 90 19.60 19.60 0.00 _0 00 1.60 19.60 19.60 0.00 0 00 190 .19 60 0 00 ^1.90 19.60 0.00 0.00 10_92 " -1 18 16.79 16.79 0.00 0.00 200 6 30 0 0 -164 "0 0 0 -312 '118 59B 0 0 194 101 504 0 - 0 0 15 0 --0 49 0 0 0 0 - 93 0 294 0 0 58 0 252 0 0 . 1.33 39.33 39.33 0.00 0.00 1.18 13 24 3.24 1.18 39.33 0.00 0.00 10.34 212 12 45 0 0 232. 82 0 272�� 60 0 0 20 __0 190 0 0 0 _ 0 �_ 0 150 .' 82 192 0 0 0 20 285 235 882 0 0 286 1599 ,e,u,_„„ 0 365 1176 0 0 223 472 772 1770 0 _0 178 1080 ,,,,,.,,,,_,-,„,_0 227 2360 0 0 211 112 12 15 0 0 .0. �0 .0 0 0 0 0 0 110 0 0 0 ��0 0I�� _._.�_ �..,�._...__0 0 0 0 0 0 235 294 294 0 0 0 0 0 0 0 0 138 472 590 590 0 _ 0 - 0 _____.�.-0 0 0 0 0 0 C- F -1eA-39d 226-1ph =6032 = _0.90 38_02 _P 24 0.00 .=16 = 16 =:14 =36 0 ==O 240 - 0 26 =O 989 _ =0 __0 1_358 962 120 45M 6 c)AEDexcursion 0 _293 Envelope loss/gain 10740 7367 2128 1217 12 a) Infiltration b) Room ventilation 1770 0 414 0 383 0 90 0 13 Internal gains: Occupants ® 230 Appliances/other 0 0 WOO 0 0 2400 Subtotal (lines 6 to 13) 12510 11581 2511 3707 14 15 Less eMemal load Less transfer Redstribution Subtotal Duct loads 19% 18% 0 0 0 12510 2M 0 0 0 11581 2085 19°/> 18% 0 0 0 2511 470 0 0 0 3707 667 Total room load Air required(cfm) 14MJ b27 13666 627 2981 126 4374 201 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -PW wrlgtitsoTC- 2019-May-0809:20:47 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 1 A&k EADocumnets\Wrightsoft HVAC\POLK RESIDENCE.rup Cato =MJ8 Front Door faces: W • wrightsoft Right -A) Worksheet Job: AHU 1 Date: MAY 8, 2o1s By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCSOAOL.COM 1 2 3 4 5 Room name E>pmed wall Room height Room dimensions Room area BATH 8.0 it 8.0 it heal/cool 7.0 x 8.0 it 56.0 ft2 OFFICE 22.0 it 8.0 it heat/cool 13.0 x 9.0 it 117.0 ft2 Ty Construction number U-value (Btuf✓ftWF) Or HTM (BtuiVft2) Area (it) or perimeter (it) Load (Btuh) Area (ftq or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 11 12E-0sw 2 glazing cir low-e 2 glazing cir low-e 2 glazing cir low-e 2,glazing, clr,lowe_ 12E4xsw 2 glazing, cir low-e 2 glazing, cir [low-e=-a 2 glazing, cir low-e 2 glazing cir low-e '12E�w -*; 2glazing cir low-e. :2glazing,_clr low-e- 12E-Ilsw 2 glazing, cir low-e 2 glazing, cir lave 2 glazing, cir low-e 1100 6068 0.700 0.700 0.650 -0.650 0.068 0.700 0.700 0.650 0.650 0.068 0.700 _0.650.,_,s_ 0.068 0.700 0.650 0.650 0.390 n n n n -n_ a a a a a -a s w w w w w 1 90 1960 19.60 000 0.:00 1.90 19.60 19.60 0.00 0.00 1 90 ':1960 _AA 1.90 19.60 0.00 0.00 10.92 1.16 16.79 16.79 0.00 -0.00 1.18 39.33 39.33 0.00 0.00 i, f-e 13.24 0.00 1.18 39.33 0.00 0.00 10.34 64'--58 6 0 0 0 0 0 0 0 0 -' 0 0 _,_0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 ` _ 0 0 0 0 0 0 110 118 0 0 __0 0 0 0 0 0 0 0 0 0 0 0 0 0 69 101 0 0 0 0 0 0 0 0 ..-m- - 6 .. 01 0 0 0 0 0 72 '0 15 0 -0 0 0 0 0 0 .� 0 1 =10 104 30 0 0 0 57 0 0 0 __0 0 0 0 0 0 --0 0 74 0 0 0 0 709 0 294 0 0 0 0 0 0 _ 0 �-. 0 0 141 588 0 0 0 - 67 0 252 0 0 0 0 0 0 0 � 6 a 88 1180 0 0 0 VVVVVVyffI11 `G- 141 iC= ,16A30atl. _0.092 =090 '_.�224 0 ==O - 0 0 �16 ,,__16 =4 F 22A-tph 1.358 38.02 0.00 56 8 304 0 117 22 837 0 8 c) AED elaursiorl -29 323 Envelope loss/gain 532 140 1982 1946 12 a) Infiltration b) Room ventilation 118 0 28 0 324 0 76 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 200 0 0 0 Subtotal(lines 6to 13) 650 368 2307 2022 14 15 Less e#emal load Less transfer Redistribution Subtotal Duct loads 19% 18% 0 0 0 650 122 0 0 0 368 66 19% 18% 0 0 0 2307 432 0 0 0 2022 364 Total room load Air required (cfm) 772 33 434 20 2738 116 2386 109 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ -FW wrlfxln, e- 2019-May-08 09:20:47 Right -Suite® Unlverse1201818.0.31 FISU08101 Page 2 .�A E:\Documnets\Wrightsoft HVAC\POLK RESIDENCE.rup Cale = MJ8 Front Door faces: W wri htsoft° Ri ht-J® Worksheet Job: s AHU 1 Date: MAY 8, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: OUICKCALCS@AOL.COM 1 Room name HALL FAMILY ROOM 2 3 Bgxsed wall Room height 0 1t 8.0 it heat/ccol 38.0 it 8.0 it heat/cool 4 Room dimensions 6.0 x 4.0 ft IS 21.0 x 17.0 ft 357.0 ft2 5 Room area 24.0 Ty Construction U-value Or HTM Area (ft� Load Area (ftq Load (Btuh) number (BtuFVftz F) (Btuhlft� or perimeter (it) (Btuh) or perimeter (it) Heat I Cool Gross N/P/S Heat 7 Cool Gross N/P/S Heat Cool 8 12E-Osw d:6A n `7 90 1 18 - 0 = 0 �� 0 -0 0 0'-', 0 - 0 2 glazing cir low-e 0,700 n 19.60 16.79 0 0 0 0 0 0 0 0 2 glazing cIrlow-e 0.700 il 1960 16.79 0 0 0 ^ �0 0' 0 0. - 0 2 glazing cir low-e 0.650 n 000 "_- 0.00' 0 - 0 0- 0 "o 0 0._m�___0 -- 0 0 - 0 0 ' 0 11 2glazing,clrlow:er,„,-. __.___0.650 n -,0.00 ___-Q0o 0'' •- 0 0.-_. 12E-0sw 0.0 a 1.60 . 0 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.77000 a 19.60 39.3333 0 0 0 0 0 0 0 0 2 glazing cir Iowa 0.700 a 19.60 39.33 0 0 0 0 0 0 0 2 glazing of low e 0.650 e 0.00 0.00 0 0 0 0 0 0 0 0 0 2 glazing cir lowe, 0650 a 000 000 0 0 0 0 0 0 0 '�"' 'N 12E OSW 0.068 'S -1 g0 f 7- 0 b _ 0 .' . 0 -136' 95 . 1731 113 2 gluing clr)ow-e 0.700 s t 1960 13.24 o 0 = 0 - 0 41 i 41 Boo 540 glazng, olr low;,g;-,_ 0.650 -;,.:0 00 , 0 00 .��,,,,,0 „„.,m,___„_Q m „,.. 0 ;: : 0 Q - 0 -------0 0 V ,_,^,,, 0.700 ,,;-s w 1.60 1.33 0 0 0 0 130 110 139 2gluiw 2 glazing, cir low-e 0.700 w 19.60 39.33 0 0 0 0 30 0 58B 588 1180 80 2 glazing, cir low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 W 0.00 0.00 0 0 0 0 0 0 0 0 D 11DO 0.390 w 10.92 10.34 0 0 0 0 20 20 223 211 '" :. ' 0,(ki2 .W„...,..A.90 . .2 4 b r.,-..„;_.:.o , _,..�_.0 .�..�.._,.®:0 - -0 _:.. .�0 ._..445 0 C.,_e..2A-30ad F ,.... 22A-iPh z _ _ _;,.,� _-„ 1 358 �„ 98 02 0.00 24 0 0 0 �357 38 1445 �.., 0 rn.« n- -e-.® 6 c) AED erxursion 0 143 Emelope loss/gain 0 0 3461 2326 12 a) Infiltration 0 0 560 131 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 0 0 0 0 Appliances/other 0 1200 Subtotal (lines 6to 13) 0 0 4021 3657 Less external load 0 0 0 0 Less transfer 0 0 0 0 0 0 Redistribution 0 0 0 0 4021 3657 14 15 Subtotal Duct loads 19% 180/6 0 0 19% 18% 752 6W Total room load 0 0 4773 4315 Air required(cfm) 0 0 202 198 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -F;F wr!q lx9oYe- 2019-May-OB 09:20:47 Right -Suited Universal 2018 18.0.31 RSU08101 Page 3 Ask EADocumnets\Wrightsoft HVAC\POLK RESIDENCE.rup Cale =MJB Front Door faces: W wri htsoft Ri Right-J® Worksheet Job: a AHU 1 Date: MAY 8, zot9 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466.6796 Email: OUICKCALCS@AOL.COM 1 Room name DINING ROOM 2 EVWed well 26.0 it 3 Room height 8.0 it heat/cool 4 Room dimensions 14.0 x 12.0 it 5 Room area 168.0 ft2 Ty Or Area Load Area Load Construction (Btuh/ftz°F) (Btuh/M� pe imeter (it) (BBi or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heal Cool 6 12E'-Osw - CA68 n 1 90 1.18 �0 y 0 0 0 2 glazing clr low-e: 0.700 n` - 19 60 16.79' = 0 0 0 0 2 glazing clr low-e 0.700 n 19 60 16.79 0 0 0 0 2 glazing oil, low-e 0.850 n 0.00 0 00 0 0 0 0 11 II-�--GGG 2.glazing clr lowre�;.....-.. 4.,__0.650 -„n_ „,.._-,.0.00 ,__._0.00 0 ' 0 0 -0 .,.... � ._ WVly�I1 12E-Osw 0.068 a 1.90 1.18 112 82 156 97 2 glazing, or low-e o 0.700 a 19.60 39.33 0 0 0 0 2 glazing, r low-e 0.700 a 19.60 39.33 30 0 580 1780 2 glazing, clr low-e 0.650 a 0.00 0.00 0 0 0 0 2 glazing clr low-e 0.650 a 0.00....__.. 0.00 0 ..,....., 0 0 ...._.__.e_ ......�.-..- ., 12E Osw ..._ 0.068 s 1 90 1,78 _._._..�.0 96 55 _ 105 . 651, 2:glazmg,'clr low-e 0.700 s 1960 13.24 41 47 800 540 _ dr Iowa _ ._ 0 650 s _ ,;„ 0 00, �q.00 _9 „,;Y.- 0 _2.glazmg, 12E-0sw 0. w 1 1 0 0 0 0 2 glazing, clr Iowa 0.700700 w 60 19.60 33 39.33 0 0 0 0 2 glazing, clr low-e 0,650 w 0.00 0.00 0 0 0 0 2 glazing, clr low-e 0.650 w 0.00 0.00 0 0 0 0 D 11D0 0.390 =0,032 w 1092 =90 10.34 =2.24 0 ==O 0 ra:70`®,.:v_0 0 0 =5 ,. -.. rC.v.:a F ,18A-30ad.== 71A-,iPh 1.358 , 36.02 0.00 160 26 _989 6 c)AED elxursion -144 Envelope loss/gain 2638 1738 12 a) Infiltration 383 90 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 3021 1828 Less eAemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 3021 1828 15 Duct loads 19% 18% 565 329 Total room load 35M 2157 Air required (cfm) 1 151 99 ,c wrlg�+tsofe- 2019-May-08 09:20:47 Right-Sulte® Universal 201818.0.31 RSU08101 Page 4 . A EADocumnels\Wrightsoft HVAC\POLK RESIDENCE.rup Calc = MJ8 Front Door faces: W wrightsoft' at Ri ht-JO Worksheet D AHU 2 Date: MAY 8, zols By: QUICK CALCS, INC. %17 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466.6796 Email: OUICKCALCSWAOL.COM i 2 3 4 5 Room name EWed wall Room height Room dimensions Room area AHU 2 126.0 it 8.0 1l - 970.0 112 WIC 3 3.0 ft 8.0 ft heaVcool 3.0 x 8.0 it 24.0 ft2 Ty Construction number U-value (BtXluei F) Or HTM (BtuFVft�) Area (ftzl or perimeter (it) Load (Brun) Area (ft.) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 12E-Osw 2 glazing, clr low-e 2 glazing, clr IOW-e. 2 glazing, cir low-e. 2_glazing ,cl[lowe,.,,,.... 2 glazing, or low-e 2 glazing, 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, 1r low-e 12E-�w 2 glazing, clr low-e 2glazing,�clr low,_e 2 glazing, clr low-e 2 glazing, 2 glazing, clr low-e 2 glazing, clr low-e 11 DO - tph ...,-..._.�...=-� OA68 0.700 0.700 0.650 ,m.-,_,_.-.0.650 0.700 0.700 0.700 0.650 0.650 0.068 0.700 0:650 0.700 0.700 0.650 0.650 0.390 � 0-032 `�.' ..... .,1.358...._..m n n n n -n_ a a a a a s s .,.,,s_ w w w w w --90 000 0.00 18 20 _.„_ &20 0.00 0.00 0.00 18,20 18.20 t 90 0.00 r-,,,.78 20 1.00 0.00 18.20 18.20 0.00 0,90 0 00 1 16 0.00 0.00 13.94 11.30 1.00 0.00 0.00 28.97 28,97 T 1-8232 0.0o 13:94 1.00 0.00 28.97 22.08 0.00 ,,.224.E_970 0.00 232 0 0 30 ----.J5 270 0 0 6 45 . ". 0 ` 82 270 0 45 30 0 ._. 0 ` 187 0 0 - 0 _0 221 0 0 0 , 0 150 0 ",.�;.,�,82 190 0 0 0 0 !�^- 9 00'.=869 �...�:... � : 350'� 0 0'0 546 ,,,-, 273 421 0 0 109 819 -286 , 0 _1485 370 0 819 546 � 0 ....�,.�._ O 2P1 0 418 170 261 0 0 174 1304 178 0 „n____7135 233 0 1304 662 0 � '2773:. -0, '�'� 0 0 , 0 0 0 24 0 0 0 _ 0 --'-0 a, 0 0 0 0 0 0 =24 0 0 0 0 0 -'0-0 24 0 0 0 0 0'-m 0 0 0 0 0 0 0 __.„_=24;-�._.w.22 -.m...-_0 00 0 0 46 0 0 0 0 0 :0 ,..�.;_,,,,,e,„: 0, 0 0 0 0 0 0 -0 -0 _ 0 28 0 0 0 0 - 0 :_._.�.,..._0 0 0 0 0 0 �„.--54 0 _ _-r v�1�C C'����'��°-16A.30ad F,22A 6 c)AED excursion 0 -6 Em,elope loss/gain 6905 8235 67 76 12 a) Infiltration b) Room ventilation 1858 0 435 0 44 0 10 0 13 Internal gains: Occupants ® 230 Appliances/other 0 0 1500 0 0 0 Subtotal (lines 6 to 13) 8763 10170 111 87 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 27% 35% 0 0 0 8763 2342 0 0 0 10170 3513 27% 35/ 0 0 -111 0 0 0 0 -87 0 0 Total room lead Air required(cfm) 11104 627 13683 627 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -P�+- wrlghltsotP[- 2019-May-08 09:20:47 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 5 A E:\Documnets\Wrightsoft HVAC\POLK RESIDENCE.rup Calc = 10J8 Front Door faces: W wrightsoft Ri ht-M Worksheet Job: AHU 2 Date: MAY 8, 2o1s By: QUICK CALCS, INC. zn AT I NCIF I ANE. FORT PIERCE. FL 34946 Phone: 772-466-6799 Fac 772-466-6796 Email: OUICKCALCS®AOL.COM 1 Room name BATH 2 BEDROOM2 2 3 Egoosed wall Room height 5.0 it 8.0 it heat/cool 25.0 it 8.0 ft heat/cool 4 Room dimensions 5.0 x 8.0 ft 13.0 x 12.0 it 5 Room area 40.0 ft- 156.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Oil Load number (Btutditi'F) (BIUIVft') or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 "-" 12E-0sw 6.068 n "1 80 1 18 . 0 0 0 -' 0 .- 0 0 0 . 0 2 glazing clr low -a. 0.700 n 0.00 0.00 _ 0 0 0 0 ".,0 0 0 0 0 2 gluing, clr low-e: 0:700 n 0.00 0.00 0 0 0 0 0 0 0 2 glazing clr 16wi a glazing, cir low_s_ 0.650 _,_._..0.650 , n „n- 18.20 =. S 20 13.94 0 ,` 0 0 0'-0 0 0 ` 0 0 i -() 0 __0 0 0 .2 12E-0sw 0.068 a 1.90 1.18 40 34 65 40 104 74 141 88 2 glazing, cir low-e 0.700 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.700 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 a 18.20 28.97 6 0 109 174 0 0 0 0 2 glazing cir Iowa _, 0.650 a 18 20 28 97 0 0 0 0 30 0 546 ._.. 105 869 �65. Y�j1-C 12E-Osw 0,068 s -190 116- 0 07�"�0' - 0-"" 96. 55 2.g1azing cir low-e, 0.700 s .` 6.00 0.00 - 0 -. 0 0 ' 0 - 0 !- 0 .0 0. 0 0 0 - --Al ----41 _743 v,_569. 12E-0sw 0. w 1.0 1. 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.700700 w 0.000 0.0000 0 0 0 0 0 0 0 0 2 glazing, or low-e 0.650 w 18.20 28.97 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 22.08 0 0 0 0 0 0 0 0 11DO 16A 306d--7=i- 0.3m -0.032 w _m... 000 �..0.Ed 0.00 =224 ,0 � 40 0 �- .40 0 ,w,v36 _ ` - 0 .90 0 �16�6 �0 .,p,.-.m,.156 0 ;�,,, L40 0 C. 1.358 - 0 00 0 00 0 0 0„ 0 ___„� 0 ______,_0 T_ 0 0 �� s:, «---•---�.-.. : ........emu ......,._. ,.....o.. ram..... .e..._....a--5.,-...- �.�._::..�......._. ..v._� ' . . 6 c)AED excursion -21 -130 Envelope loss/galn 210 283 1674 1810 12 a) Infiltration 74 17 369 86 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 284 300 2043 1896 Less odemal lead 0 0 0 0 Less transfer 0 0 0 0 Redistribution 110 138 106 136 14 Subtotal 393 2149 2032 15 Duct loads 27% 35% 105 27% 35% 574 702 Total room load 499 ]27 2724 2.734 Air required (cfm) 28 154 125 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -Op-wrl_9Fr!®oT[^ 2019-May-0809:20:47 Right-Sulte® Universal 2018 18.0.31 RSU08101 Page 6 AA EADocumnets\Wrightsoft HVAC\POLK RESIDENCE.rup Calc = Wit Front Door faces: W wrightsoft' Ri ht-J® Worksheet Deb' AHU 2 Date: MAY S, 2019 By: QUICK CALCS, INC. an ST I MIF LANE. FORT PIERCE. FL 34946 Phone: 772466-6799 Fax: 772466-6796 Emil: QUICKCALCS@AOL.COM 1 Room name M WIC W/D 2 3 Exposed wall Room height 3.0 ft 8.0 ft heat/cool 0 It 8.0 ft heat/cool 4 Room dimensions 10.0 x 3.0 ft 4.0 x 3.0 ft 5 Room area 30.0 ftz 12.0 ft' Ty Construction U-value Or HTM rea A(fV) Load Area (ft� Load number (BlutVfti°F) (BtuNft� or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 4}�l---G 12E-bsw "' "" 0:068 n 90 1 18 '- 0 0 ""`�' � 0 -:0 0 0 0 0 2 glazing cir Iowa- 0.7W n O 00 0.00 0;^ 01 0 '0 0 0 0 0 G 2 glazing cir low a 0.7130 n 0 00 0 W '0 0' 0 0 0 0 0 0. �LGG 2 glazing cir Io" 0.650 n ` 18 20 13.94 0 01 0 :0 0 ' : 0 01 - 0 11 2 glazing-cidome„..,_ ..,..-a-,. 0.650 ,_.n» -..._18.20 ,,..., 11.301 0 -..y O 0 -n . 0' 0 - 0 ;„_0 WWWWWW 12E-0sw 0.068 a 1.90 1.18 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.700 a 0.00 0 .00 0 0 0 0 0 0 0 0 2 glazing, or low-e 0.700 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, or low-e 0.650 a 18.20 28.97 0 0 0 0 0 0 0 0 2 glazing clr low-e 0.650 a 18.20 28.97 0 0 0 �' 46 0 28' 0 0 0 0 0 �� 0 0 0 Vj/"�" 12E-Osw - 0068 3 1 90 418 24'� 24 F�-CC 2glazing cir low-e 0.700 s 0W O:W .0 - 0 0 '-0 0:. 0 0 0 2.glazing, cir low_e�, 0 „650 ,,,s r 20 � 13:94 D ;.0 - 0 ___„,,„„ 0 0 '. 0 -0 _____0 1PE-0sw 0.7 w 1.00 1. 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.700 W w 0.00 O.00W 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 28.97 0 0 0 0 0 0 0 0 2 glazing, clr lows 0.650 w 18.20 22.08 0 0 0 0 0 0 0 0 11DO 0.390 w 000 0.W� 0 O 0 0 0 �®0 0 ;1_ 30ad:...„..... �.-=.0,032 :..__. =.0.90 ..,,.,;,-2 24 .�. 30 ,.- =- _o R_0 .�::-._.;.27 ..,_,ate Z ..r�� 1 „2 ,v:.__,___I2 =_„=-11. u...e27. F 22A;[ph 1.358 - 0.00 0.00 0 00 0 0 .,,____,,,._0 0 0 ._...,_ .....__...e.w..,..=emu _........:......-®.:.:._ u-..v .. _..-i,..,.a -_:: �-.......w ...�.._ .....» u_...,u_�,_:-..__.�. ....�»«� MOT 6 c)AED excursion -7 -2 Enwlope loss/gain 73 89 11 25 12 a) Infiltration 44 10 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 0 0 0 0 Appllarces/other 0 0 Subtotal (lines 6to 13) 117 99 11 25 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -117 -99 -11 -25 14 Subtotal 0 0 0 0 15 Duct leads 1 27% 35% 0 0 27% 359/6 0 0 Total room load 0 0 0 0 Air required (cfm) 0 0 0 0 .L -TiF wrlghemoTe- 2019-May-08 09:20:47 Right -Suite® Universal 201818.0.31 RSU08101 Page 7 '�AEADocumnets\Wrightsofl HVAC\POLK RESIDENCE.rup Cale =MJ8 Front Door faces: W - ++ wrightsoft' Right-J® Worksheet Job AHU 2 Date: MAY 6, 2o1s By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466.6796 Email: OUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM M BATH 2 3 Eposed wall Room height 28.0 it 8.0 It heat/cool 24.0 it 8.0 it heat/cool 4 Room dimensions 14.0 x 14.0 it 1.0 x 119.0 it 5 Room area 196.0 ft' 119.0 ft2 Ty Construction U-value Or HTM Area (fh) Load Area (ftR) Load number (Btuhlfti*F) (BtUWft2) air perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E=Osw; 0.068 n 1 90 1.18 0 -: 0 " "'? 0 -' '72 57 70 9 67 2 glazing cir low-e 0.700 n 000 000 0 ,0 -,- 0 0 0. 0 �0 0 2 glazing; drlow-e: 0.700 n 000 0.00 0 - 0 0 '0 0: 0' 0 0 2glazing cirlow-e 0.650 n ` 1820 13.94 0 0 0' 0 0 01 0 0 it ,2.glazing„clrJow�;_�. _0.650 _n_ 18.20 ,._._11:30':,-„-_0 s;� o _,0 m_e.____.0 15 ,_.,..._._._0 _-_..a273. ;_,_ _170 ,_.. 0,700 a 1.00 1.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 gluing, 0.700 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.700 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 28.97 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 e 18.20 28.97 0 0 0 �136 T 0 00 µ 0 '� 0 vd4� 72E-0sw 0:066 s M _ 1 90 1.18 - 112 71 84 0 0 0 0 2.glaz1ng cirlcw-e-- 2.glazing, 0.700 s, -.-000 18 20 000 13 94 0 ,- Al, 41 0 41 0 _ 1,�,�„-743 -`0 -.-, 669 0 :0 z:0 --A 0 __,-„_,--,0 0 -.-_ 0 w 0.700 w 1.00 1.00 110 82 150 97 120 90 171 100 2 glazing, or low-e 2 glazing, 0.700 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 28.97 30 0 546 869 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 22.08 0 0 0 0 30 0 546 662 D 11 DO ; Bp.-30ad 0.390 032 w ��.„ 0.00 ._._�0.00 0.00 ;0.00 0 ,.,,,,,,,,,,„,J90 _ 0 ` ,s196 0 „,:=','176 0 .e.,,., 439 0 t19 - 0 �.178 0 ."�.-.,..107 _, _ 0 _„;,.__267 C_ F ,� ,22A,Ich _..____0 1.358 ;.._ ....0.00 0,00 0 0 0 0 0 0 0 0. .-.- 6 c) AED excursion 35 173 Ernelope loss/gain 1756 2093 1206 1446 12 a) Infiltration 413 97 354 83 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13) 2169 3090 1529 Less external load 0 0 11690 0 Less transfer 0 0 0 Redistribution 216 329 227 14 Subtotal 2385 3418 1756 15 Duct loads 27% 35% 637' 1181 27% 35% 606 Total room load 3023 4599 2141 2362 Air required (cfm) 1 171 211 121 108 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed _ -PW =Lqn! -M- 2019-May-0809:20:47 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 6 EADocumnets\Wdghtsoft WAC\POLK RESIDENCE,rup Calc=MJB t Front Door faces: W wrightsoft° Ri ht-JO Worksheet Job: AHU 2 Date: MAY 8, zD1s By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORTPIERCE, FL34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: OUICKCALCS^BAOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area HALLWAY 5.0 it 8.0 it heat/cool 1.0 x 141.0 it 141.0 1l2 BEDROOM 3 25.0 it 8.0 it heat/ccol 13.0 x 12.0 it 156.0 ft2 Ty Construction number U-value (BtulVftL1F) Or HTM (Btuwft2) Area (ft2) or perimeter (it) Load (Btuh) Area (ft2) or perimeter (it) Load (Btuh) Heat I Cool Gross N/P/SrHeal Cool Gross N/P/S Heat Cool 6 11 12EOsW 2 glazing cir low-d 2 glazing clr low-e 2giazing clr low-e �2 glazing-clr lavice;,�, 12E-Osw 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 gluing olr low-e 2,gluing clr low-e 2;glazing clr low,e 12E-Osw 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, off low-e 11DO 22A;,Iph 0.068 0,700 0.700 0:650 _____ A�650 0.068 0.700 0.700 0.650 0.650 OA68 0.700 0_650 0.068 0.700 0.660 0.650 0.390 ..�,„,_..e 0.032 1.358 n n n n ._n- a a a a a a s -a- w w w w w .®-i 90 0.00 '0 00 18 20 __._18 20 1.90 0.00 0.00 18.20 18 20 - 1 90 000 15 20 1.90 0.00 18.20 18.20 0.00 '.�_0.90 0.00 1.18 0.00 0.00 13.94 _11.30 1.18 0.00 0.00 28.97 28 97 1 18' 000' 13 94 1.18 0.00 28.97 22.06 0.00 _,„,..„.2.24 0 0 - 0 0 _,.._.,.v.,�0 0 0 0 0 0 ° 0 - 0 _,,;, Q 40 0 15 0 0 _..�..141 ,.e. _O ` o = 0 0 0 0 0 0 0 0 0 0 0 ,,,_„_-0 25 0 0 0 0 _ve: m _741 .�L� O ;.' 0 „„„,�.uD 48 0 273 0 0 ..-.0.126 {1 0 0 0 ,,,.�.„„,:�0 0 0 0 0 0 0 0 -_._.9 30 0 435 0 0 �3j6 96 0 0 15 _-0 104 0 0 0 _15 0 0 �10 0 0 0 0 0 ,.,.�_„„,156 - 81 0 0 0 a.�,„,._._.0 89 0 0 0 0,___n_273 0 0 _.._ 0 0 0 0 0 0 15496 0 0 273 � 0 169 0 0 0 .: 0 0 �...Y_ � 0 0 0 0 0 Y-_. 0 0 0 209 0 105 0 0 0 _43512E0sw 0 0 ......�..._._.. 9 0 0 0 0 0 ....� .„. D F� .-�.0 ......m.., 0 9 -,..-O - r,......9p 6 c)AED excursion 111 -102 Envelope loss/gain 447 891 1009 1093 12 a) Infiltration b) Room ventilation 74 0 17 0 369 0 86 0 13 Internal gains: Occupants @ 230 Appllances/other 0 0 0 0 0 300 Subtotal (lines 6 to 13) 521 g08 1378 1479 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 270/ 35% 0 0 -521 0 0 0 0 -908 0 0 27916 350% 0 0 110 1488 398 0 0 138 1617 558 Total room load Air required (cfm) 0 0 0 0 1886 106 2175 100 9hmofC- 2019-May-08 09:20:47 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 9 .45MA E:\Documnets\Wrightsoft HVAC\POLK RESIDENCE.rup Cale =MJ8 Front Door faces: W wrightsoftRight-J® Worksheet Date: AHU 2 Date: MAY 8, 2D1s By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 FeK 772-466-6796 Emil: OUICKCALCS®AOL.COM 1 Room name STAIRS 2 Mq:osed wall 8.0 it 3 Room height 8.0 it heaUcool 4 Room dimenslons 12.0 x 8.0 it 5 Room area 96.0 it - Ty Construction 1-1-value Or HTM Area (ft2) Load Area Load number (BWWftMF) (Btutdfv) or perimeter (it) (Bluh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 0w- . 1 4 93 586 2 glazing cir low -a 0.700 n 000 0.00' 0 ,0' 0 -0 2 glazing clrlow-e"; 0700 n 000 0.00 0 0'. 0 ;0 2 glazing cir low-e. 0.650 n 18.20 13,94 15 . -' ' 0 273 209 . 2 glazing,dr,low:e.,,„..._0.650 „„n_ :.......18 20 11.30 :..»_._--0 - 0 ___0 0 12E-0sw 0. a 190 1 0 0 0 0 2 glazing cir low-e 0.700700 e 0 0 0 0.0000 0 0 0 0 2 glazing cir low-e 0.700 e 0100 0.00 0 0 0 0 2 glazing cir low-e 0.650 a 18.20 28.97 0 0 0 0 2 glazing,,. cir low-e 0.650 a 18.20 28_97 0 0 0 ��0 0 12EOs -w 0,686 s ' 1 90 1.18 0 r. 0 2.glazmg cir low e' 0.700 "` s 0.00 0.00 0 ` 0 0 - O 2 gI&mg,-cir lov_e;� _0:650 s. 0 ,,,„_73.94 ' 0 12E-0sw 0.068 w 1.90 1.18 0 0 0 0 2 glazing, cir low-e 0.700 w 0.00 0.00 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 28.97 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 22.08 0 0 0 0 D 11DO 0.390 w 0.00 0.00 0 0 0 �0-032 , 0 90 =2:24 :..,=c:',s:�96 ,T "�:„„86 _0 2i5 . ___..___ :.�....,__........._.� F 22A-IPh _ ._ L358 � _ . 0.00 0_09 _...,„,,.,_0 w=-.,„..-e,0 �»-_.. 0 ______0 u 6 c)AED exursion -52 Envelope lossrgain 452 430 12 a) Infiltration 118 28 b) Room ventilation 0 0 13 Internal gains: Occupants ® 230 0 0 Appliances/other 300 Subtotal (lines 6 to 13) 570 758 Less eaemal load 0 0 Less transfer 0 0 Redistribution 87 151 14 Subtotal 657 909 15 Duct loads 27% 35% 176 314 Total room load 833 1223 Air required (ofm) 47 56 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ #F wrr9ti�o4C� 2019-May-0809:20:47 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 10 I&A EADocumnets\Wrightsolt HVAC\POLK RESIDENCE.rup Cale = Wit Front Door faces: W -- wrightsoft° Duct System Summary • AHU 1 Job: Date: MAY 8, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: OUICKCALCS@AOL.COM it-roject intormation For. POLK RESIDENCE, GEM BUILDERS 5204 CITRUS AVENUE, FORT PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm 233 ft Supply Branch Detail Table Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 772 33 20 1.000 5.0 Ox0 RtFg 18.0 200.0 sti DINING ROOM h 3586 151 99 1.000 7.0 Ox0 RtFg 37.0 160.0 sti FAMILY ROOM h 2387 101 99 1.000 7.0 Ox0 RtFg 39.0 180.0 sti FAMILY ROOM -A h 2387 101 99 1.000 7.0 0x0 RtFg 32.0 170.0 sti KITCHEN C 2187 63 100 1.000 7.0 Ox0 RtFg 27.0 190.0 sti KITCHEN -A C 2187 63 100 1.000 7.0 Ox0 RtFg 19.0 200.0 stl OFFICE h 2738 116 109 1 1.000 7.01 OxO RtFg 28.0 205.0 stl Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk sti Peak AVF 627 627 1.000 798 12.0 0 x 0 RectFbg Return Branch Detail' Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat] Trunk rb2 OxO 627 627 0 0 0 0 Ox 0 RtFg 1 wrightsoft• 2019-May-08 09:20:49 ^, »�—,m•... Right-Sulte® Universal 2018 18.0.31 RSLI08101 Page 1 ��EADocumnels\Wrightsoft WAC\POLK RESIDENCE.rup Calc=MJ8 Front Door faces: W - wrightsofte Duct System Summary AHU2 Job: Date: MAY 8, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Far. 772-466-6796 Enroll: QUICKCALCS®AOL.COM iLroject iniormanon For: POLK RESIDENCE, GEM BUILDERS 5204 CITRUS AVENUE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 iN100ft 627 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm 131 it Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 499 28 27 1.000 5.0 Ox 0 VIFx 12.1 115.0 st2 BEDROOM h 1886 106 100 1.000 7.0 Ox0 VIFx 15.8 115.0 st3 BEDROOM2 h 2724 154 125 1.000 7.0 Ox0 VIFx 9.1 115.0 st2 M BATH h 2141 121 108 1.000 7.0 0x0 VIFx 14.9 115.0 st3 MASTER BEDROOM c 2299 85 105 1.000 7.0 Ox0 VIFx 12.1 115.0 st2 MASTER BEDROOM -A c 2299 85 105 1.000 7.0 OXO NIFX 14.9 115.0 st2 STAIRS c 1223 47 56 1.000 6.0 OxO VIFx 9.4 115.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk SO Peak AVF 274 264 1.000 621 9.0 0 x 0 VinlFlx st2 Peak AVF 353 363 1.000 666 10.0 0 x 0 VtnlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) _ Stud/Joist Opening (in) Duct Mat[ Trunk rb1 OxO 627 627 0 0 0 0 Ox 0 1 VIFx wrlghtsof[' 2019-May-0809:20:49 �.� ' .w....,�,.n Rlghl-Sulte® Universal 2018 18.0.31 RSU908101 Pa e 2 ZeAP, EADocurnnets\Wrightsoft HVAC\POLK RESIDENCE.rup Calc=MJ8 Front Door faces: W This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.