Loading...
HomeMy WebLinkAboutGAS PIPING SCHEMATICBOARD OF COUNTY . COMMISSIONERS TANK SIZE [Al] IAZ] GAS PIPING SCHEMATIC TANK SIZE:2 x1�10 0 GALS. APPLICANCE — TYPE/SIZE Al Ge,"'-+or A2 D&GL . PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division RECEIVED DEC 10 2018 ST. Lucie County, Permitting SCANNED BY St. Lucie County [AS] ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FORCOMPLIANCE REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSP CTION WILL BE MADE 9a 1 z Zbo, 006 BTU o' 000 BTU A3 bIU A4 BTU A5 BTU A6 BTU PIPING LENGTH & SIZE Ll �,z, FT. 3/4 INCH DIA. L2 3 FT. 3/IF INCH DIA. L3 zS FT. 3/4_INCH DIA. L4 Z FT. �/N INCH DIA. L5 FT. INCH DIA. LIS FT. INCH DIA. L7 FT. INCH DIA. L8 FT. L9 FT. L10 FT. L11 FT. L12 FT. Revised 7/22/14 INCH DIA. INCH DIA. INCH DIA. INCH DIA. INCH DIA. (PIPE SIZE WAS TAKEN FROM THE 2014 FBCFUEL GAS CODE - TABLE 402 (__J) FILE COPY Wehsite: www stlucieco.aov 2300 Virginia Avenue - Fart Pierce, FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578 7 Z yy�� xe .,n .x e , ll- ��. � � • s {, + y ,� � � ' ter_, Ru- 04. a » r ,f i )Styx"#. _ +"^3�' T\tr .:� X �. kA �. e n.uT «f' .o'er-''yw i•�\°6 � � A s: a. +r✓ ti :>'cvS�li '`�' ,t +s`n��` a„�l CY f-'r ys'. .,s.,� ur, a a` tibSs.`" -r ,.,� "',',' r. `r+� ' � $'+'d-1 e xa9.1 "v' y }�^�ba u... a t �''•-�, �a,n� k. t si a'v'1wv-� y rr $t bx Py-y�, „p ""' u s r •^. - AS"x '!9" � . ' �a. a � �..� � a v&'r '. '"f� 1 a x _ P` � �M •' 3 a, a= - r' [)3"�� p � ' S ' - - �, a, ' , ,`' "` ;.� �Y • 1 ZOa arkland B_ou3evard m+1�{ y{.` y • Ursa::•: 0 - � . - �, .. 's- -•r R µ 4ht{ i ex� s a i Tw++}wu.'�,.. fyhv r .,d }" ^ .� �' �� ti. ` ���� " ��x Par ,''$ 1 r �r -�, '�"+- v'r• ° and Bivd Parkl nd BNdEm Parkland GOO - le Raarkla no Blvd -_ ;� kland Blvd 12(8/2018 40239_44394 1.jpg(800.800) httpsllwww.paslc.org/imageSketches/sketch/40/40239_44394_1.lpg 1/1 -Anw*- RECEIVED AM0eX***Y DEC 10 2018 iF66i,My1M1%� $ 11�±1.a94�1N ST,'Lucie County, Permittft Corrugated stainless steel tubing (CSST) gas piping systems will be bonded in accordance with Section G2411.1 (310) of theFlorida Building Code and NFPA 54. ■ Underground gas piping will be installed at a minimum depth of 12 inches below grade in accordance with Section G2415.12 (404.12) of the Florida Building Code and NFPA 58. ■ Polyethylene pipe will be installed in accordance with 6.11.4 of NFPA 58 and the Florida Building Code. Carbon monoxide monitors will be installed prior to inspection and will meet all code and safety requirements of NFPA 54 and the Florida Building Code. Application Walter use as a first stage regulator on any domestic s¢e ASME or DOT container In propane gas installations requiring up to 1,500,000 BTU's per hour. The regulator is factory set to reduce container - pressure to an intermediate pressure of approximately 10 PSIG. Features • compact design can be connected to a service valve using either a POL adapter or a RegO product pigtail. • Large threaded W FNPT bonnet vent can easily be piped -away underground installations without the need of glue kits or extra adapters, • Non Adjustable . • Large flow orifice resists freeze ups due -to water concentration in LPG vapor. • Design provides for good flow regulation at both high and low container; pressures. • Built In relief valve and travel stop comply with NFPA 58 over pressure requirements. • Incorporates % F.NPT downstream pressure tap for an easy Inline check of the regulator's delivery pressure. • Molded diaphragm provides an o-ring type seal between the body and bonnet. • Body and bonnet are assembled In the USA using the unique, patented RegUlok seal system. ' • Fully painted In brilliant red for Complete corrosion protection. • Mounting bracket available as an accessory: part number2302-31. Ordering Information Materials Body ..... :........... ......^......... .......................................................... Zinc Bonnet................:............................................................... Zinc ................................ SpringtDis.................^..^..................... Seat Disc ..:............^..^....�..................................ResillentRubber . Diaphragm .............. .. integrated Fabric and Synthetic Rubber ■OEM ■\M .,N LY YO ,M Ae EEO TW WLb. 91UM. • '15E.EEE [OT! IP1AW IpNAN ,.».� 12m� UdEDN neWPAeMNE '/° FF.N NPT I % PT I W I 10 PSIG r- —I 1.500.000 a gn pressure 20PSIG hlgherg n lheregWalercetWgwd deriverypme mMlower regWaipseM,odderiuerypreesu<e20%10rN ft nm9 A14 100 RegGer.P.o.ans2470on. NC 27244 USA xwrvregopmduds.mm FhN(336)4494707 Fe3(336)""594 MRQ Designed to reduce first stage pressure of 6 to 20 PSIG down to burner pressure, normally 11' w.c. Ideal for medium commercial Installations, multiple cylinder installations and normal domestic loads. Feat w • Large went helps prevent blockage and has v.° ENPT for vent piping ' • With 15 PSIG inlet pressure, regulator Is designed to not pass more than 2 PSIG with the seat disc removed. • Incorporates Integral relief valves. Replaceable valve orifice and valve seat disc. Straight line valve closure reduces wear on seat disc. Unique bonnet vent profile minimizes vent freeze over when propertyi Installed. Large molded diaphragm is extra sensitive to pressure changes. Built In pressure tap has plugged IS" F.NPT outlet. Plug can be removed with a 3/16' hex alien wrench. • Select brown finish. Body..................... ...................................... I........... Die CastZlnc Bonnet.:......:.....:...................................................... DIB Cast Zinc NozzleOrifice .... :._.._......................................................... Brass Spring........_..........,.................................................:.......... Steel Valve Seat Disc _....• ....................... :................. Resilient Rubber Diaphragm ............. 11....... Integrated FabdCand Synthetic Rubber LL911m Mounts directly to house Ilne piping. Eliminates need for union Joints, elbows, and mounting brackets. Quick and easy to Install. 2 •BacW unldesl9n - ^Madmum 11owbased on 10 PSIG Inlet and 9'wx. deliverypressure. 117"MRSULes 1 :r n n ni .:1 a •I 1,000M 10DRM M6 100RegDDr. P.D.Box 247Bion.ND27244USA vn•.w.reBopmtlucls.mmPAM13S)449-7707 Faxt333J4494594.?EN-0. An w L a ^lino .o mrNmo N �i vbim arms a-ta �2M O�-°�'c• .min jN q M P:r M NN'44n N^O OQr W W C- C-bbhY9 a} m h •e. g b AO m.N N CI p M tpY rV �+mrpbm rV C• `O tO r0 Y5 r!l � R' Q q' rG q' C{ p sF p p m m m m N N do b GO pp 'rl N'•1 A! P p Q a b V v 4-r w rRi ^�iT mQ VV rp Q C InRl m RI N i •C�� � N rrypr NFNmN M MP. rO NmOC•rnp I ry 0 C• rOmmm NCIONN am OhrMr1 Y1p W P [+1P n~yp pl Cm'1 T ate O 7�e E O^ A s.l C 1f� rnm1 m r. �9 m d. rr. m : i In .b n r, a .-. ��rrpp.�.1 xv .y} r• M} '"r' (Jd �M�Crni NCIN��2.K'r�'iti • I rn RI '�'al . I�rf G try Ifl b m rn M I� p C- b t�pp 11�� dpi o Imo' b ? MNI�N. b m.rrnrn CI Clme{ �lpm Y'l"mst O M'p N W raj �r FCb -� mba m N r-1 -�Or rG m�I� ��GG NCr r'G NUrO •rFN v� N .C� M q p N .y ...1 ...y .-..-, .. I �o ro In u� v v •am M M m t�1 N iZ a a4 O Op Ot i!ZLyl 000 po pOOGO O p '� ^+ m a h O N N m ern v I�rl e F in a o rpil o U O .� tiCl P�z^e SPECIFICATIONS STANDARD OD t 48 23.6 43 47.2---- 52 99.1---- WAER.,CAdi:lTYjkasl y�i ------- 239 -- 474 ------ . 1,000 cx N�kIINA1..hjF�EIDEjF(f.�S{�� 68 142 271 CY1{dQR'J1AEI£R(Ifd;�#t`�+n 14.7 24 30 IIf,,IN17iFYAk1�2+(,ii�l)yy+] 6,616 13,120 27_680___ 'Cff�Li{+IA1Ei$k?N(i''�'s"e u. 6.5 16 — 16 Tt x,,:�y 5.1 6.9 6.9 xC�1`btAR,t��IGiis1"UNjS> fQD-�,G,diII�IT+,EEEI IIN� 2 `. 14.5 19 22 CGA-510 NO OPD CGA-510 NO OPD CGA-510 NO OPD t$TJt1v}JARQ:S$PfE+CAQi�E" DDT-4BW240 DOT-4BW240 DOT-4BW240 METRIC 11219 1092 1,321 86.7 172 - 360 WATER`�AI?AQLTK(K61nr�. 108.4 215 450 ..x:,„: NO1+Iivr113RC W51�ikj:G},.T <. 30.8 64.4 1 122.9 C�t�N4E12t�.lA1AETE(� {MM{ 373 610 762 CQLIDEf2V�, {)' 215 450 Ee �,n 4 .........__108_4_ C"t1Li,hQ,�ANjil`(M1}?"ti 165 406 406 _ QOLL`iSRFF.IfIOHTIMMI� 130 175 175 FFPIOTHINC, OIIAi•1C%E{3p-�MMI'*,r": 368 483 559 j,!Y��` '� t T't '�rF�rsd s m CGA-510 NO OPD CGA-510 ND OPO CGA-510 ND OPO 4v _ y i __ _ `$TAIARSPCIEI,�O[5�p ? DOT-4BW240 DOT-4BW240 DOT-4BW24D All dimensions are approximate. 1 T/8" COATED CA84E W/ (5 CLAMPS TO AN (PULLED 1 AS ; D ITE 6X3" OCK ANCHOR HAVE AN ALLOWABLE PULL—OUT CAPACITY OF 400g. MHORS SHALL BE INSTALLED. PER ANCHOR ,TED LOAD CAPACITY. CAPACITY VARIES WITH SOIL T1TE. VERIFY ANCHOR CAPACITY WITH SOIL NIUTIES PRIOR TO.. ANCHOR INSTALLATION 0 ADJACENT. STRUCTURES AND FEATURES IS DEPINDERT UPON LOCAL CODES AND IS THE i DESIGNED TO PREVENT FLOTATION, COLLAPSE OR LATERAL MDVEMENT DURING THE BASE is GCpi N/A; Cf = 0.6 „ N. s O CBPMR!" 2017 — FARLLY 0f0INMWG, LLC 1ERIGAS Consulting Engineer #40111 — CA24108 Moo N. U.S; 81, SuN 02 , Sobosllan, Florida 32958 (772) 882.2286 fm