Loading...
HomeMy WebLinkAboutINSTALLATION PLANcJ, u 9 z t7 m w E � N U L7 z 3 0 3 E F 9 1 g 1 7 ICE RESIDENTIAL GENERIC STRUCTURAL PLAN. FMFYT TnIESHEET G & F NO OF COMMON SOLAR COMPONENT EXAMPLES SHOWN- ACCOMMOOATEOMMLATEO WIND UPUFTA APPEARANCE MAY VARY. EaUIPMENTDEAD LOAOS.TNIS IS ATTESTED TO ONTHISONA NGATn1EVPI IRONRIDGE PV RAIL GENERIC INSTALLATION PLAN 1. THIS IS A SINGLE SHEET GENERIC STRUCTURAL PLAN. ELECTRICAL PLAN IS SEPARATELY SEALED DOCUMENT. 2. THIS PLAN OFFERS THREE INSTALLATION METHODS. a. FRAMING METHOD. SEE DRAWINGS. b. SHEETING METHOD. SEE DRAWINGS. C. STANDING SEAM/PBR (PURLIN-BEARING) METAL ROOF. USE CLAMP/BRACKET OF CHOICE; ACE. http://www.pmcind.com/aceclamp/ S-5. https://www.s-S.com/products/clamps-brackets/s-5-u-clamps/ https://www.s-S.com/products/clamps-brackets/proteabracket/ 3. CONTRACTOR SHALL MAKE .CLEAR .TO AHJ WHICH INSTALLATION DETAILS WILL BE USED. 4. SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE. 5. THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. ADJOINING MODULES SHALL SHARE MID CLAMPS. MODULES MAY BE LANDSCAPE OR PORTRAIT AT CONTRACTOR OPTION. 6. PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF FRAMING. SEE ROOF ATTACHMENT SPAN TABLE @ LOWER RIGHT 7. THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. 8. RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE OF END ROOF ATTACHMENT BY MORE THAN 1' J-i.Te F � 9. RAILS SHALL ATTACH TO ROOTIiRU'L-FEET AS SHOWN HEREON. L-FEET REQUIRE FLASHINGS WHICH CAN BE SF -SO (SELF -FLASHING, SHEETING ONLY) SHOWN HEREON OR MIN 4" x 8" x 26 GA. GALV, 0.032 ALUM, OR INDUSTRY STANDARD OEM FLASHINGS OVER ATTACHMENTS LAGGED INTO ROOF FRAMING, E.G. SOLAR MOUNT, IRONRIDGE FLASHFOOTlor2, OTHER ACCEPTABLE TO AHJ. 10. SF -SO ROOF ATTACHMENTS ARE INTENDED TO BE INSTALLED INTO SHEETING ALONE, HAVE BEEN SO TESTED AND ARE RATED AT 900-POUNDS ALLOWABLE PER ROOF ATTACHMENT. - 11. ALL FLASHINGS SHALL BE INSTALLED IN A GENEROUS BED OF FLORIDA PRODUCT CONTROL APPROVED (PICA) POLYURETHANE ROOF SEALANT. 12. LONG L-FEET &/OR STANDOFFS ARE PERMITTED AS NEEDED FOR ROOF CLEARANCE. 13. ENGINEER OF RECORD (EOR) PREFERS EMAIL COMMUNICATION: I c' ., 318-16 x 314J \ HEX HEAD BOLT WE 11 FLANGE BOLT ` FOR GALVANIZED �.-_ _ .�__ __ PLATE GASKET 6SNEENNGONLY, BEIFFVSHINGROOFATTACHMENT APPEARANCE MAY VARY /1 STANDARD OR FOR 7-IN L-FOOT. MIN. 4 #14 X 2• EMS SS \ PERATTACHME 44"„J� —3/8" SS BOLT 9 1 8 1 7 6 5 I 4 1 3 1 2 I QFBC 2017 (fiTM EDITION) FLORIDA BUILDING CODE CgozDESIGNED FOR VOLT=20O MPH., NO PLANS ON FILE - EACH PERMIT REQUIRES SIGNED & L) RISK II, EXPOSURE D. RAISED SEAL PLAN FROM FOR PV MODULE GROUNDING AMP PV RAIL SHINGLE ROOF 4- MINIMUM #12 X 2-INCH, SS, SMS D3 EHINGLE nLE,SINGLEPLY FLASHF00T 2 SEE. FIGURE 11 ASPHALT SHINGLE ROOF 3/8-16x314 HEX HEAD BOLT 3/8 - 16 FLANGE NL1r TILE SS METAL PLATE, SQUARE OR ROUND — ROOF SHEATHING Proper Flashing Placement FRAMING TFOAM ADHESIVE FLORIDA PRODUCEXISTING APPROVED SEALANT FOUR # 19 CIRS BEYOND ECK B UNDERLAYMENT BOTEWSTOM OF BOTTOM OF DECK `Fl TTILEROOFATTACHMENT 318 - 16 x 3/4 HEX HEAD BOLT, 3/8-16 C 72 NUT PV 5101GE DU E / i5MCKET 0 2 3/i6 1518 111/16 SHEATHING FRAMING 5/16" ORS.HAG W/ 3" 6MM X 25 MM BI- THREAD EMBEDMENT IN METAL SHEET SCREW BLOCKING, JOIST, OR TRUSS ,. `FU FOOT 2 SHINGLE ROOF ATTACHMENT PV RAIL MID{VU4P BUST 3/8 -16 x 314 HEX HEAD ROOF TILE 3/1-16 FLANGE NUT -- ---- PV MODULE SERRATED L ROOF MOUNT v e v ROOF SHEATH. OPTIONAL FILL CAVITY W I TILE ROOF DOW FOAM STANDOFF WATER PROOFING OR LONG WITH SONOLASTIC L-FOOT MIN. 4 #14 X 2" SMS-SS NP-1 OR EQUAL 1" BEYOND BOTTOM OF DECK POLYURETHANE CAULK I � � 1 FLARRXI Fib Rod?(i <B 527•) W X (3ehle RDDIIA57') Gahle R�_L'<AS45'1<AS15'1 ��a, ❑ Etla�O1 oae<nm P21: ROOF INTERIOR PZL ROOF PERIMETER (MIN. T Is LEAST OF40% SAVE HEIGHT OR 10%BUILDING LAV. PM: OUTSIDE CORNERS L & W - PZ2, a = PZ2 WIDTH. h - EAVE HEIGHT. M PER PROFILE O6 55PROTEABRACKET METM ROOFATTACHMENT EXIST. MED DECKING ON ROOF SHEATHING WATER PROOFING 5/16" CRS. LAG W/ 3" THREAD EMBEDMENT IN BLOCKING, JOIST, OR TRUSS e � ID PRESSURE ZONES. 5 4 3 5116 5/16 MINIMUM 3-INCH THREAD EMBEDMENT 30 SEIF RASHNGATfACHMENTPHOTO4 Na,G NR rl 55 PROTEA DMCKET I GE C.F SSU C AMr /COL IRONRIDGE Roof Mount System XR1011e0 IIaimme MR100011t11 SmWedsolm Abwpe6lamevNNOme for eBlons with Dam mnw. The ulti sfo neWentlel mlarmouMgrall. AheavywagIdmoureW mO for commercial plgecte. AB ralb ueauaa lMemd eDODas for sa&mless connectlans. • Vspeminp capability • a'sp iuMa upablIKs' • 1216pannlnpaapaWay • SNPdr0lmp sordwe • Moderate load CapabllMy • 14aavy lope eapebNy • EVrems loan eapabl0y ' VarAvveMDnsformis • QeareMbleakfWM • Clear arc! bleokenl&h • Clow anodbmd BrJeh • FOlmesscuebanft UFO@ Stapper86evf(ass OrouMae Lope Nlwamrtsr Klb FWhFwtx Slatted L.Fwt fiO1�ArLp wN`were FbW Btandorte FLORIDA ROOF ATTACHMENT SPACING (FEET): ROOF HEIGHT SO -FT 13 u : WA R 1 2 8 ROOF SLOPE <30• WIND (MPH) PZ7 PZ2 PZ3 IRONRIDGE RAIL 110 8 6 4 XR-10 120 B 6 2 XR-10 130 8 4 2 XR-100 140 6 4 2 %R-100 150 6 4 2 XR-100 160 6 4 2 XR-1000 170 4 4 XR-1000 180 ENGINEER ALLEN GEZELMAN 16602 HANNA RD. LUR, FLORIDA 33549 —PH.8139091956 A AOenQGeulmanPEcom www.GeuManPE.cpm PE 69160 DEC 0(�4 2018r GYQi.. ry^V B DRAFTSMAN: _ ALPER ICELI alpedcellLQmall.usf.edu C00 z z O Y N QW J � � W PI 0-0 SCANNED BY CONT� RACTOR:i APPROPRIATE LICENSE OR OWNER/BUILDER C E AI -I R-7 08.AUG.18 F 1 U ip.. ST.LUCIE COUNTY PLAN REVIEW BLDG: - DATE Q EL E DATE: PLUMB: - DATE' MECH:-� DATE:-