Loading...
HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY: DATE FILED: REVISION FEE: LOCATION/SITE PERMIT# 5-L'-181a?'O2 3,9 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT l CONTRACTOR INFORMATION: STATE of FL REG./CERT. it: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): OWNER/BUOWNER/BUILDERINFORMATIOyyN:: // NAME: lgari'a G—LDYe ADDRESS: r ( r- CITY: Fnr 4 wtcs^ce STATE: PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: SLCCC: 9123109 R"ISIRevised 0616/30/1/17 SCANNED BY St. Lucie County ST. LUCIE CO CERT. #: FAX: FAX: ZIP: ZIP: ZIP: EVALUATION REPORT OF UNION CORRUGATING COMPANY `26 GA. 5V PANEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 20484.1-R1 ROOFING METAL ROOFING Prepared For: Union Corrugating Company 701 S. King St. Fayetteville, NC 28301 Telephone: (910) 483-0479 Fax: (910) 483-1091 Prepared By: • Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 . Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) Load Span Table (1 Page) Report No. C2175-1 Date: 8.23.2017 Kt2CE IVED JAN 2 4 2019 Sl. Lucie County, Permitting �,O!.%�p,U N G,q'''���i v;v 62 .de :m: NLLJ Al o :ul� Op Z`e °i /�' FLOe•••'v s�• PS,S 1 O�i`•'� %•23.2c kI FL 20484.1-R1 C2175-1 8.23.2017 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: 5V Panel Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 15/32" thick APA rated plywood or min. W thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2 Design Uplift Pressure: 71.0 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) . 169.0 psf @ fastener spacing of 6" o.c. Panel Attachment: #10-15 x 2" long wood screw with washer At interior @ max 12" o.c. across panel width through panel rib At panel ends @ max 6" o.c. across panel width through panel flat and rib Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering Systems'. Test Equivalency: The test procedures in UL 1897-04 comply with test procedures prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Union load span table. This evaluation report is ` FL 20484.1-R1 C2175-1 8.23.2017 Page 3 of 3 not applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580 & UL1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T197-16, Reporting Date 5/12/16 PANEL OVERLAP �+ NEW UNDERTAYMENT ROOF PANEL EE DETAIL 2 SEE PANEL FASTENER DETAIL 1 SPACING PER ALLOWABLE UPLIFT LOAD TABLE tWOOD EXISTING (OPTIONAL) (O EXISTING SHINGLES (OPTIONAL) DECK ATTACHMENT AND PLYWOOD SUPPORTS MUST BE 15/32' THICK (MIN.) DESIGNED AND INSTALLED BY OTHERS MI.AER. JOIST/ d ' TRUSS AT MAX. 24' O.C. TYPICAL PANEL INSTALLATION X—SECTION $ I SCREWSWITH WASHER F �O^ N t9� I Z NEW UNDERTAYMENT MIN 26 GA PANEL 8 y�o EXISTING SHINGLES (OPTIONAL) EXISTING UNOERLAYMEM 6 (OPTIONAL) PLYWOOD A 15/32' THICK (MIN.) DETAIL 1 d °tom i GENERAL NOTES: R #10-15 % 2' LONG WOOD 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA SCREW WITH WASHER BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MINIMUM 26 GA EFFECTIVE COVERING WIDTH OF - PANEL - 24'. 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS NEW UNDTRLAYMENf MIN 26 CA PANEL SPECIFIED ON THIS N 4. REQUIRED DESIGNWINDLOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE — — — 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA EXISTING BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTSTHIS IST NG & THE CODE. THE CODE WIWIND (OPTIONAL)HINGLES 6 RAFTERS/JOISTS/TRUSSES MUF E DESIGNED TO WITHSTAND LOADS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. EXISTING UNDERIAYMENT (OPTIONAL) 2 PLYWOODETAIL 15/32'DHICK (MIN.) C2175-1 U „o 1 � 1 UPI^,^�VCORRUGATING COMPANY 5V Panel Uplift Loads (Min 26 ga.) Description Fastener Spacing Allowable Uplift along Panel Length Load (in) (psf) Coverage width: 24" 6 ------- 169.0 8- - - -- — Panel Fasteners 10 147.2 #10-15 hex head screws with 12 136.3 sealed washer -_—_ 121.7 - - -- --14 ---- - -- Panel fasteners spaced at 12" 18 94.7 o.c. across panel width --- -- _ - 20 - - --_--85.2 - - through ribs. -- - - 7_7.5 __- -- --- 22 - ---24 - ------- 71.0 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 20484.1 and Union current installation procedure. 1216 N Lansing Ave., Suite C 1 Tulsa, Ok 74106 918 492 5992 4.Z•3.2C, 1-1 Bala Sockalingam, Ph.D., P.E. FL 62240