HomeMy WebLinkAboutPOOL PAPERWORK101Zt - C2 6-Z Unit SpecificationsSCP B St. Lucie SQ125 SQ145 S0225 SQ120R SQ166R INN SO/8q 101, 000 119,000 143,000, 110 000 ',,126 000 ,; BTUs ,„ „k:s ::__ 2 , K • , 80/8/63 95,000 112,000 134,000 103,000 120,000 (watertemp/ambient air/ relative humidly)�- _ 90 000 72 000 +r 82,000 J5.5 C.O.P. 80/80/80 6.5 6.8 6.5 5.6 Coefficient of Performance 80/80/63 ` ' a. ' 1 64.2 (watertemp/ambient art 80/50/63 4.0 4.0 4.0 4.0 relative humidity) RefrigerantR4i0P g r '`fi410A&` ;R410F1' R410A ;' R41'OA, Electrical Heat or Heat & Cool H H H H&C H& C l P 2 T Voltage/Hz/Phase A A B& G A B E& G A& B A B E& G A- 208-230/60/1 B - 200-230/6013 Maz Fuse Srze A? 60 A 60 11 60 A 60 ` A 60 E - 380-415/60/3 G- 460/60/3 « � - =G 25= i k G ,25 ` �„.>,: ,, �,�. x s1.: a•.,,€ Min. CircuitAmpacity A-40.5 A-42.1 A-42.1 A-38.5 A-42.1 B-31.0 B-33.3 B-31.0 B-33.3 G-14.2 E-18.4 E-18.4 G-16.2 G-16.2 Mi Water Flow A Heater Bypass Kt Is required when flow rates exceed the maximum m Physical Y r •.1=:.� .",-„. _ ._ �, a ,«rvs .-� r e x y - Length x width x Height (in) 34" x 34" x 44" 34" x 34" x 44" 34" x 34" x 44" 34" x 34" x 44" 34" x 34" x 44" Shipping Weighf�ib1 ?_' �. _''a ` 329 •T 390�f`. ?390._;. h329,- 39Q.`• I� Length x Width x Height (In) 38" x 36" x 49" 38" x 36" x 49" 38" x 36" x 49" k 38" x EY' x 49" 1 38" x 36" x 49" --------------- ------- ----------------------- ----------- ------- ------ ------- -------� FEATURES Unblockablel All components meet or exceed vas ANSI/APSP 16-2011 and NSF/ANSI 50-2009a national standards and ASTM G 154 UV testing exposure Three parts: bottom 21W OD, 2' ID SiS- Inside 2"threaded FPT, two 2"th"eaded plugs included'dw'Sdr'°°s,°'°^Way PVC sump (standard) d °.. Designed for use with 2"hydrostatic retie( valve part #HVxxx (see page 1 11) Disposable plastic pre-gunite/plaster insert keeps debris out and retains sump shape during construction Does not require the use of transition glue k316 stainless steel screws Manufactured from superior UV -resistant engineered polymers Online product support including2`y't" downloadable CAD riles, certificate ��b6 of conformity, third -party certificate, Installation. instructions and more Replace drain cover every five years from the date of Installation 4 per case With sump (concrete pools) Part N 32CDFLxxx STANDARD COLORS El 32CDFL107 -White 6 � 33 r 32CDFL1 02 - Black r-5/16 6 I r tit 14-9/32 r —r 4 pr'e�rr U 32CDFL703-gh[Gray k S� 3 __ r r 32CDFL104-Blue r �5-9/15 1 32CDFL105-Dark Gray 32CDFL108-Tan I I— io—. —10—I 2-1/2" Spigot x 2" Socket x 2" NPT Also available as sump only p/n 32CDPrxx 1. 32" Three -Port PVC Sump 4 per case 2. 2" Tapered Threaded Pipe Plug, Qty 2 3. Port Divider Also available cover only without 4. 32" Channel Drain Plaster Shield sump,?ame p/n 32CDFI.Wxxx 40 per case 5. 32" Channel Drain Flush Cover 6: 10 x 314" Flat Head Phillips, 316 SS, Qty 16 %'G8 2008 Compliant Plaster Shield And Screws To Be Removed After Gunite/Plaster Applicatlon