Loading...
HomeMy WebLinkAboutNUTTING ENGINEERS PAPERWORKERMINES of Florida Inc. I Established 1967 a ,w' Your Project is Our Commitment v V i w m v E c 0 c w c 0 V v 0. _c v c m w c v F- CM c ai c c w m a) Y c 0 Y V i a. N 0 V a c u C s u w 0 v v March 4, 2019 Apex Pavers and Pools 725 SE Monterey Road Stuart, Florida 34994 Re: Pool Backfill Evaluation Foust Residence 2656 Conifer Drive Ft. Pierce L Permit No.: B Z -(20 I 675 SW Biltmore�ee�t Port St. Lucie, Florida 34983 772-408-1050 Toll Free:877-NUTTING (688-8 Fax: 772-408-1049 Palm Beach 561-736-4900 Broward 954-941-8700 Miami -Dade 305-557-3083 www.nuttingengineers.com RECEIVED MAR 13 2019 sT. Lucie countrt r9 tnitdng Nutting Engineers of Florida, Inc. has performed geotechnical engineering services for the referenced project. The area between the house and the proposed pool was probed with a Static Cone Penetrometer to determine the level of compaction of the backfill material. Results of the probes are provided below: Test Location Depth ft CPT tsf % Compaction West end of pool by steps 0-1 35 95+ West end of pool by steps 1-2 30 95+ West end of pool by steps 2-3 40 95+ North end of pool between pool & house. 0-1 35 95+ North end of pool between pool & house. 1-2 30 95+ North end of pool between pool & house. 2-3 40 95+ East end of pool. 0-1 35 95+ East end of pool. 1-2 35 95+ East end of pool. 1 2-3 1 40 1 95+ It is our opinion that the pool backfill as indicated by the above test locations has been compacted to a density of the order of 95 percent modified Proctor. We appreciate -this opportunity to be of service. Should you have any questions, please contact o ltiQfi W1gk our convenience. .-,\\� e n r- - /i. �* No4266 /%`_ • 6 STATE'0 '�. 3ossi, P ro t &"to /ONAI. Apex Paversll</FJQgIFltVV1 OFFICES Palm Beach Miami -Dade St. Lucie INC. ai a, L a, Ln C QJ E c 0 c w c 0 U V C a _c V c ro w C Y v zr c m c c w .y a, Y c 0 U Y N C 0 V a C N m V C U ai 0 ai C7 Tutting NORMS of Florida Inc. I Established 1967 Q YourProjectis Our Commitment March 4, 2019 Apex Pavers and Pools 725 SE Monterey Road Stuart, Florida 34994 Re: Pool Backfill Evaluation Foust Residence 2656 Conifer Drive FtP'erce, FL Permit No.: -18,1 -02r71 615 SW Biltmore Street Port St. Lucie, Florida 34983 772-408-1050 Toll Free:877-Nl1TTING (688-8 Fax-772-408-1049 Palm Beach 561-736-4900 Broward 954-941-8700 Miami -Dade 305-557-3083 www.nuttingengineers.com Nutting Engineers of Florida, Inc. has performed geotechnical engineering services for the referenced project. The area between the house and the proposed pool was probed with a Static Cone Penetrometer to determine the level of compaction of the backfill material. Results of the probes are provided below: Test Location Depth ft CPT tsf % Compaction West end of pool by steps 0-1 35 95+ West end of pool by steps 1-2 30 95+ West end of pool by steps 2-3 40 95+ North end of pool between pool & house. 0-1 35 95+ North end of pool between pool & house. 1-2 30 95+ North end of pool between pool & house. 2-3 40 95+ East end of pool. 0-1 35 95+ East end of pool. 1-2 35 95+ East end of pool. 2-3 40 95+ It is our opinion that the pool backfill as indicated by the above test locations has been compacted to a density of the order of 95 percent modified Proctor. We appreciate this opportunity to be of service. Should you have any questions, please contact \fat(v(lli�gkgurconvenience. * ` No 4211X6f1 ` STATEI II ssi, P rot I 10 TONAL Apex Pavers/!(/fJ44'FOO OFFICES Palm Beach Miami -Dade St. Lucie DA, INC.