Loading...
HomeMy WebLinkAboutEVALUATION REPORTFILE COPY NEOREC$� Certificate ofAu[hohzatlon #32455 353 Christian Street, Unit #13 Oxford, CT 06478 0 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY ""WICIN REPORT Boral Roofing Evaluation Report M36710.12.30-Rli FL14317-RlO 7575 Irvine Center Drive, Suite 100 SCANNED Date of issuance:12/21/2010 Irvine, CA, 92619 BY Revision 11: 10/12/2018 (602) 269-2288 St. Lucie County SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use o construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOI etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8 Prepared b y' P so�q P.E. '•?Nz:!_e•s: '"• ''••;t The facsimile seal appearing was authorized by RobeR Robert J.M. Nieminen, ;„•� Nieralnen,P.E.on10112/2018.Thisdoesnotsewesean Florida Registration No. 59166, Florida DCA ANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: ' 1. NEMO ETC, LLC does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC, LLC Is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturingor distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Ig rd for any S. project nuwhich this E aluation Repocode evaluatio. rt, or previous versions thereof, is/was used for permitting or designher NEMO ETC, LI-C nor Robert Nieminen, P.E. are, In any way, theOgu danceunless retained specificallyfor that purpose. 0 0 ONEMOletc. ROOFING COMPONENT EVALUATION: Sub -Category: Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing have demonstrated compliance with the following sections of the Gth Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. " Section. .J'" `• Wind Uplift - - - UL 1897 2012 1504.3.1 1507.1.1, T1507.1.1, Physical Properties ASTM D1970 2015 1507.2.9.2 Physical Properties FRSA/TRI April 2012 (04.12) 2012 1507.3.3 REFERENCES: Ent' - Fxamal Pro e , .Reference .:. -;Date 09/30/2011 ERD (TST 6049) Physical Properties M36790.07.11 B40380.08.12 08/28/2012 ERD (TST 6049) Physical Properties Tensile Adhesion / LTA C41420.09.12-2 09/11/2012 ERD (TST 6D49) Adhesion 841940.09.12 09/1/2012 3 ERD [TST 6049) ERD (TST 6049) Tensile Adhesion / LTA B47390.07.14-1 07/31/201 09/ 4 9/04/201/201 ERD (TST 60491 Tensile Adhesion / LTA B47390.09.14 Equivalency statement OC (PDM1838) Physical Properties NEI-031-02-02:REV 10/27/2010 PRI(T5T 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010 PRI (TSr 5878) ASTM D1970 Tensile Adhesion / LTA NEI-046-02-OIREV 12/17/2010 12/17/2010 PRI (TST 5878) FRSA/TRl April 2012 NEI-076-02-01 PRI(TSr 5878) ASTM D1970 NEI-034-02-02 01/14/2013 PR((TST 5878) Wind Uplift BORR-001-02-01 01/29/2013 PRI(TSr 5878) Wind Uplift BORR-005-02.01 03/17/2015 PRI (TST 5878) Tensile Adhesion / LTA DAPF-002-02-01 06/24/2015 03/08/2018 PRI (TST 5878) ASTM D1970 (adhesion) OCF-443-02-01 10/ 1/201/2020 PRi (TST 5878) UL, LLC. (QUA 9625) Quality Assurance Service Confirmation 4.1 Boral® TIIeSeal se is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS moditie0 DRumen roo, underlayment; meets ASTM D1970. 3 Boral® TileSealin is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof 8—underlayment; meets ASTM D1970 and FRSA/TRI 04-12. -mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof 4.3 Basal® MetalSeal"r is a nominal 60 underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.4 GaterSealu is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. c-surfaced, fiberglass 4.5 CitaclelO Plus is a roofing underlayment for i use asila base -layer in multi ply underlayment systems; self-adhering ineets IASTM D1970. bitumen Evaluation Report M35710.12.10•R31 NEMO ETC, LLC FL14317-RID Certffi ofAuthMzotian #32455 fi^' EDITION (2017) FBC NON-HVH2 EVALUATION Revision 11: 10/12/2018 aural Roof Undedayments; (602) 269.2288 Page 2 of 8 J � i ONEMOletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer_ of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. - 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof o...,.. «,.+he ,....eucAnn incrriunions for multi-olv underlayment options. TABLE I: ROOF COVER OPTIONS ' - - Asphalt Underlayment Nail -On Tile Adhesive -set Wood Shakes Me4a1 Slate metal &Shingles Shingles Boral TileSeal 50w Yes No No Yes Yes Yes Sorel TileSeal"T Yes Yes Yes (See 5.5.1) Yes Yes Yes Boral MetalSeal"T Yes Yes Yes (See 5.5.1) Yes Yes Yes GatorSeal Yes No No No Yes Yes 5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations. - - Adhesive FloridaProdud� Approval Underlayments. DAP Foam Touch'n Seal StormBond Roof Tile Adhesive FL14S06 Boral TileSeal"T ar Bora1 MetalSeaPn DAP Foam Touch'n Seal StormBond 2Two-Co mponent FL21374 Boral Tilesealw or Boral MetaiSealm Polyurethane Roof Tile Adhesive Dow TILE BONDTM Roof Tile Adhesive FL22525 Boral TIleSeal"T or Boral MetalSeal"T ICP Adhesives Polyset° AH-160 FL6332 Boral TileSeaf'r or Boral MetalSeal' ICP Adhesives Polyset° PTA-1 FL6276 Boral TileSealw or Boral MetalSealm J Refer to Tile Manufacturer's or Adhesive Manufacturers Florida ProductApprovai for Overturning Moment Resistance Performance NEW ETC, LLC Evaluation Report 1435730AL10-11131 CeMQcote ofAuamraotfon@32E55 6T"EDITION (20171 FBC NON-HVHZ EVALUATION FL36317-R30 Boml Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 3 of 8 ONEMOletc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Citadel Plus, Boral TileSeal 50HT, Boral TileSeal"', Boral MetalSeal"T or GatorSeal: Plywood (unprimed or primed with ASTM D41 primer). Boral TileSealHT or Boral MetalSealw: ➢ OSB (unprimed or primed with ASTM D41 primer). Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the overlying roof cover is adhesive -set the roofing 5.6.2 Bond to Base Laver Underlavment: Citadel Plus, Boral TileSeal50', Boral TileSealHT, Boral MetalSealH or GatorSeal: ➢ ASTM D226, Type II felt; Citadel Plus. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under adhesive-settile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC 1504.3.1. 5.6.3 Bond to Other Substrate Types: Citadel Plus, Boral TileSeal 50H1, Boral TileSealHT, Boral MetalSealRT or GatorSeal: ➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.). Boral TileSealHT: ➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. 5.6.4 Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-22) and are used in adhesive -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the. ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads #1 Maximum Design Pressure=-220.0 post: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 to the plywood deck Base Ply: Citadel Plus, self -adhered Cap Sheet: Boral TileSealHT or Boral MetalSealn self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x IX" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure = -142.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: None Cap Sheet: Boral TileSealHT or Boral MetalSealn self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. Evaluatian Report M35710.12.10-R31 NEMO ETc, LLC FL24317-R10 eerv]-=te of Authorization#32455 hie EDITION (2017) FBC NON-HVHZ EVALUATION Boral Roof Underlayments, (602) 269-2Z88 Revision 11: 10/12/2018 Page 4 of 8 ONEMOletc. #3 Maximum Design Pressure=-202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSealworBoral MetalSealw,self-adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x IYo" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-210.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK #89 Sta-Tak Primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSealw or Boral MetalSealn self -adhered, and back -nailed within theselvedge-edge side laps using 12 ga. x 1Y." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure=-120.0 psi: Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional) Citadel Plus, self -adhered Cap Sheet: Boral TileSealRr or Boral MetalSeal"r, self -adhered 5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 5.7 Exposure Limitations: GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover. Boral TileSeal 50', Boral TileSealw or Boral MetalSealw shall not be left exposed for longer than 180-days after installation, prior to placement of final roof cover. Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than 180-days after installation, prior to placement of subsequent underlayment layer. 5.8 Tile Slippage Limitations IFRSA/TRI April 2012104-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. 6.1 Boral Roof Underiayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. ' 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40°F and rising. NEMO ETC, LLC Evaluation Report M35710.1L10-R11 Centilmre o/Authonvotion 432455 6TM EDITION (2017)FBC NON-HVHE EVALUATION F14317-R10 Boml Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 5 of 8 4NEMOletc. 6.4 Citadel Plus: 6.4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral TileSeal 50"r, Boral TileSealm or GatorSeal. 6.4.2 Slope limitations are those associated with the top -layer underlayment. 6.4.3 Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y.-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive coursesthe entire width of the black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"r, Boral TileSealHT, Boral MetalSeal"r or GatorSeal. 6.4.4 To Base Sheet: Install base sheet of ASTM D226, Type f felt in accordance with Code requirements or install base ply of Citadel Plus in accordance with Boral Roofing published installation instructions and. Section 6.4.3 and when used as part of a multi -ply system. Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and Section 6.4.3. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50n Boral TileSeal"r or GatorSeal. Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 6.5 Boral•TileSeaf5CF: 6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment In FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.5.2 Do not use Boral TileSeal 501 on roof pitches less than 2:12. 6.5.3 Non-TileADolications Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y.-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal under end'(vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO ETC, LLC Evaluation Report M35710.12.10-Rll Cenifimte o)Authamafion D32455 61e EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RID Boral Roof Underlayments: (602) 269-2288 Revision 12--10/12/2018 Page 6 of 8 8 ONEMOjetc. 6.5.4 Non -Tile Applications to Base Sheet: Install ASTM M26, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal 50HT in accordance over ASTM D226, Type 11 felt or Citadel Plus with Boral Roofing published installation instructions and Section 6.5.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.6 GatorSeal: 6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be Installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:12. 6.6.3 Non -Tile applications Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by X-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions. 6.6.4 Non -Tile Applications to Base Sheet: Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install GatorSeal OVerASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.6.3 except end (vertical) laps, described below. Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is In contact with the granular top surface, rolling the interface into place with a weighted roller. 6.7 Boral TileSeal"' or Boral MetalSeal" : ` 6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment In FBC Table 15o711 for the type of prepared roof covering to be installed. 6.7.2 Do not use Boral TileSeal"T or Boral MetalSeal"T on roof pitches less than 2:12. 6.7.3 Non -Tile Applications Direct to Deck: For OSB substrate, prime with ASTM D41 primer and allow t0 dry prior to installation. Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. Evaluation Report M35710.12.10-R31 NEMO ETC, LLC FL14317-R10 Ceniflone ofAuMorizotim N32455 0 EDITION (2017) FBC NON-HVHI EVALUATION Revision 11: SO/12/2018 Boral Roof Underlayments; (602) 269-2286 page 7 of 8 ONEMOletc. 6.7.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or Install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSealw or Boral MetalSeal"T over ASTM D226, Type II felt or Citadel Plus In accordance with Boral Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.7.5 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2022 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. Note: For adhesive -set tile systems, if there is abase ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeaF or Boral MetalSeal"T with roof pitches of 2% to less than 3:12. Boral Roofing's Elevated Batten System or counter battens are required. BUILDING OERWIT m As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Brentwood, NH UL, LLC. — QUA9625; (631) 546-2458; END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report M35710.12.30-R11 Certlficcte ofAuthorlmdon 432455 67' EDITION (2017) FOC NON-HVHZ EVALUATION FL14317-RlO Ronal Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 8 of 9 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization 99503 353 CHRISTIAN STREET, UNIT#13 E-RD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT East Coast Metals, Inc. Evaluation Report E10240.0g.06-R4 SCANNED FL5374-R4 2301 West 8 Lane BY Date of issuance: 09103/2008 Hialeah, FL 33010 St. Lucie County Revision 4: 03/17/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use o construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nleminen, P-E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building code sections noted herein. DESCRIPTION: East Coast Metals Channel Metals LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrmitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ERD Evaluated" may be displayed in ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity) advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert I.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 Thet:uimta sealapp¢arinEvas aWh.,hed by "ben N!envom P.E on W/17/20s5. Thudcesnii' eMo asan eleamn!callysii{ned dowinene Si¢nedsealetl hastlmpies have aeent2mminetlmths pmdu APpmvalAdM!N mmrandtothemmedc4ent CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acaulre, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. products for 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing p which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, e Designer of Recor or any the project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.3.7 Installation, non-HVHZ FRSA/TRI April 2012(04-12) 2012 1518.8.1 Installation, HVHZ RA5118,13.9 & 120 1995 1523.6.5.2.2 Static Uplift Resistance TAS101 1995 1711.2.1 Static Uplift Resistance SBCCI SSTD 11 1997 3. REFERENCES: Enti Examination Reference Date ERD (TST6049) Static Uplift Resistance E42730.08.13 08/23/2013 ERD (TST6049) Static Uplift Resistance ECWSC6795.22.14-1 02/27/2015 ERD (TS76049) Static Uplift Resistance ECtvi-SC6795.12.14-2 02/27/2015 Florida TEC(TST7393) TA5201 520-62SR 10/27/2010 PRI (TST5878) TAS101 ECM-001-02-01 09/21/2001 PRI(TST5878) TAS101 ECM-003-02-01 05/13/2008 PRI(TSTS878) TAS101 EC10-004.02-01 06/13/2008 PRI(TST5878) TAS101 ECM-005-02-01 06/13/2098 PRI (TSTS878) TAS101 ECIVI-006-02-01 06/13/2008 PRI (TS5878) TAS101 ECM-007-02-01 06/13/2008 PRI(TST5878) TAS101 ECM-008-02-01 06/13/2008 Florida Building Code Attachment Requirements FRSA/TRI April 2012(04-12) 04/2012 Florida Building Code -HVHZ Attachment Requirements RA5118, 119 and 120 1995 East Coast Metals Metal Quality Mi[ICertifimions Various Architectural Testing (QUA1844) Quality Control Participation Letter Exp.12/31/2018 4. PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Hip & Ridge Channel Metal is available in 119-3/8-inch (± 3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch L 3/8-inch) heights with 1.5-inch (±1/16-inch) deck -flanges. a.Rterior Research and Design, U.C. Evaluation Report E70240.08.08-114 C ni%$ate afAuthonmtion 09503 F 374114 Revision 4: D3/17/201S ?age 2 of 7 4.2 Trim Lock Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded In FBC Approved roof tile adhesive. Trim Lock Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlockwith the overlying tile adhesive. Trim Lock Channel Metal is available in 119-3/8-inch (± 3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights with 1.5-inch (±1/164nch) deck -flanges. 4.2 Trim Lock Pius Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in F8C Approved roof file adhesive. Trim Lock Plus Channel Metal is characterized by Its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive and its perforated deck flanges, designed for installation atop the roof underlayment via placement in FBC Approved roof tile adhesive, which flows -through and interlocks with the underlying adhesive. Trim Lock Plus Channel Metal is available in 119-3/84nch (±3/8") length by 3, 3.5, 41 5 or 64nch (±3/8-inch) heights with 1.5-inch (±1/164m:11) deck -flanges. 4.4 East Coast Metals Channel Metals are fabricated of the following metals: r Galvanized Steel: Min. 0.019 ± 0.002-inch, ASTM A653 (G-90), min. 33 KSI. i Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, AZ55, min. 35 KSI. > Aluminum: Min. 0.032±0.002-inch, ASTM 13209, 3003-H14, min. 211CSI. D Stainless Steel: Min'. 0.019±0.002-inch, ASTM A240/A480, T304, min. 35 KSL 5. LIMITATIONS: either tyrJERD 5.1 building ny project on which this) Evaluation Report, orrprevoNusversienninen, P.E. e This is a ions thereof, used for permitting , in any Way, the Designer of Record foraor design guidance unless retained specifically for that purpose. Evaluation Report E10240.08.08-R4 Exterior Research and ➢esfgn, I.I.C. FL5374-R4 Cerlikate ofAutheri wren g9sa3 Revision 4: 03/17/2015 Page 3 of 7 TRI47f ER® 5.2 FOR HVHZ JURISDICTIONS: 5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, .Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock:.Plus Channel Metal, refer to the installation instructions herein. 5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and 120, and the data in Tables 1A and 1B is supplemental to these prescriptive allowances. Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,J or uplift resistance (F,), as determined in accordance with RAS 127, not greater than the followinilvalues. Referto the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details. Y "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy, tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. I I ➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. - TABLE IA: PERFORMANCE LIMrTATI0N5- HVHZ, INDEPENDENT PADDY PLACEMENT (2 To I N0IRGM OFSAFETYAIAMYAPPUEO) Hip/Ridge Metal Tile Adhesive Allowable Performance Design Metal Type Type Placement Moment Based Uplift Based Mr(ft-lbf) F'(Ibf) Hip &Ridge galvanized [layer 3M`"2-Component Foam independent 127 169. Channel Metal concrete Roof Tile Adhesive AH-160 Trim Lock galvanized, Galvalume°, clay or 3M'"2-Component Foam Independent 171 159 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Trim Lack Plus galvanized, Galvalume°, clay or 3M"'2-Component Foam Independent 177 165 aluminum or stainless steel concrete RoafTile Adhesive AH-160 TABLESB: PERFORMANCE Limrm 10Ns-HVHZ, INTERDEPENDENT PADDYPLACEMENT (4 w 1 W RO1N OFSAFETYALRFADYAPPL1W) Hip/Ridge Metal Tile Adhesive Allowable Performance Moment Based Uplift Based Design Metal Type Type Placement M,(ft-ibf) F'(Ibf) Trim Lock or Trim galvanized, Galvalumee, day or 3M'" 2-Component Foam Interdependent 95 88 Lock Plus aluminum or stainlesssteel concrete Roof Tile Adhesive AN-160 Trim Inch galvanized, Galvalumee, clay or 3M'" Roof Tile Adhesive Interdependent 99 94 stainlesssteel concrete RTA-1 Trim Inch aluminum day or 3M"' Foam Roof Tile interdependent 90 84 concrete Adhesive RTA-1 Trim Lod[ Plus galvanized, Galvalume°, dayor 3M-Foam Roof Tile Interdependent 90 84 aluminum or stainless steel concrete Adhesive RTA-1 i Trim Lack galvanized, Galvalumee or dayor TILE BOND"' Roof Tile interdependent 123 117 stainlesssteel concrete Adhesive Trim Lock aluminum dayor TILE BOND'" Roof Tile Interdependent 79 73' concrete Adhesive Trim Lock Plus galvanized, Galvalume9, clay or TILE BOND"' Roof Tile Interdependent 79 73' aluminum or stainless steel concrete Adhesive Trim Lock galvanized, Galvalumee or day or Touch'n Seal StormBond Interdependent 146 139 stainlesssteel concrete I Roof Tile Adhesive Trim Lock Aluminum clay or Touch'n Seal StormBond Interdependent 58 S4 concrete Roof Tile Adhesive Trim Lock Plus galvanized, GalvalumeO, dayor Touch'n Seal StonnBond Interdependent 58 54 aluminum orstainless steel concrete Roof Tile Adhesive Exterior Research and Design, U.C. evaluation Report E10240.08.08-114 Certirmte cfAuthodrudea#9303 - F1-8374-114 Revision 4:03/17/2015 Page 4 of 7 5.3 FOR NON-HVHZIURISDICTIONS: 5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lack Plus Channel Metal, refer to the installation instructions herein 5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in accordance with Table 3A'of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile adhesive manufacturer's published installation instructionsfor adhesive paddy placement details. T "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited to 2-part the adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. D "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE2A: PERFORMANCE LIMRATONs—NON-HVHZ, INDEPENDENT PADDY PLACEMENT (2 Tol MARGINOFSAFETYALRMDYAPPLIM) Hip/Ridge Metal Tile Adhesive Allowable Uplift (psf) Design Metal Type Type Placement Hip &Ridge galvanized day or 3M"'2-Camponent Foam Roof Independent 169 Channel Metal concrete Tile Adhesive AH-160 Trim Lock galvanized, Galvalume-, aluminum or clay or 3M'" 2-Component Foam Roof Independent 173 stainless steel Concrete Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume', aluminum or day or 3M'" Z-Component Foam Roof Independent 178 stainless steel concrete Tile Adhesive AH-160 TABLE 213: PERFORMANCE LIMITATIONS—NON-HVHZ;INMDFFENDENr PADDY PLACEMENT '(4TO1MARGINOF5AFErYALRFADYAPPUED) - - Hip/Ridge Metal Tile Adhesive Allowable Uplift (Psf) Design Metal Type Type Placement Trim Lock or Trim galvanized,Galvalume", aluminum or day or 3M"2-Component Foam Roof 98 Lock Plus stainless steel concrete Tile AdhesiveAH-160 Interdependent Trim Lock galvanized, Galvalume° or stainless clay or 3M— Foam Roof rile Adhesive Interdependent 110 steel concrete RTA-1 Trim Lock aluminum clay or 3M'" Foam Roof Tle Adhesive Interdependent 93 concrete RTA-1 Trim Loci( Plus galvanized, Galvalume', aluminum or clay or 3M"' Foam Roof Tile Adhesive Interdependent 93 stainless steel concrete RTA-1 Trim Lod( galvanized, Galvalume' orstainless day or TILE 80ND'"Roof Tile Adhesive Interdependent 152 steel concrete Trim Lock aluminum dayor TILE BOND'" Roof Tile Adhesive Interdependent 82 concrete Trim Lock Plus galvanized, Galvalume', aluminumar clay or TILE BOND" Roof Tile Adhesive Interdependent 82 stainless steel concrete Trim Lock galvanized, Galvalume°or stainless clay or Touch'n Seal StormBond Roof Interdependent 148 steel concrete Tile Adhesive Trim Lock Aluminum day or Touch'n Seal StormBond Roof Interdependent 61 concrete Tile Adhesive Trim Lock Plus galvanized, Galvalume°, aluminum or clay or Touch'n Seal StormBond Roof Interdependent 61 stainless steel concrete Tile Adhesive Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4 Certificate ofAuthorization 99503 FL5374-R4 Revision 4: 03/17/2015 - - ----- --- - — Page of7. TRIKHTY ERD 6. INSfALLAMON: 6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in accordance with FBC Chapter 23 to the satisfaction of the AM. 6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1'G-inch long x 3/8-inch head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be positioned %finch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to FBC RA5118, Drawing 13, Detail 3; RA5119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. 6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it to set-up prior to installation of roof tiles. View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation 63.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not disturbed prior to or during placement of the ridge tiles. 6.3.2 Approved underlayments are the codified'30/90' system or other FBC Approved roof underlayments listing approved use of the subject the adhesive. evaluation Report E70Z40.08.08-114 e erlor Research and Design, LLC. FL5374.p4 rcrtifkare afAatharizatian 99503 Revision 4: 03/17/2015 Page 6 of 7 RINFTY ERC 6.4 The shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, published installation Instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS 118, RAS 119, RAS 120 requirements. Hip / Ridge Tile Tile Adhesive Trim Lock Plus Mortar or Weather Block Adhesive Tile Adhesive View of Trim Lock Plus Channel Metal installation after Weather Blocked 6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance priorto placement of adhesive. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named OA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 OA requirements. 9. QUAOTY ASSURANCE ENTITY: Architectural Testing, Inc.—QUA1844, (717) 764-7700 - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report E30240.08.08-R4 [erdj?mre OfAnrhorhor n995M FL5374-R4 Revision 4: 03/17/2035 Page 7 of 7 J EXTERIOR RESEARCH & DESIGN, LLC- Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 TRINITY: ERD OXFORD, CT 06478 (203)262-9245 EVALUATION REPORT - Entegra Roof Tile, LLC SCANNED Evaluation Report E39310.11.11-1-R4 a , r_ FL7804-R10 M �.GRA 1289 NE 9m Avenue BY f issuance: ll/02/2011 L Okeechobee, FL 34972 St. Lucie County Date oRevision 4: 10/17/201 (602)515-6933 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6' Edition (2017) Florida Building Code (HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named produd(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityiERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityIERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida OCA ANE1983 The laubn0eaeal appeen,om autho, ed by Robert IfemNeN P.E on 10/1)/101). Tlda does notsenre as aneleK,oNWllysigned dnament 9gned,sealed hedoapin Wee hen wremaloed to the P,.&d Avp,.l MonMbtretor and to the named dent CERTIFICATION OF INDEPENOENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra,Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the fallowing Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1523.6.5.2 Physical Properties TAS 112 1995 1523.6.5.2 Wind Driven Rain TAS 100 1995 1523.6-5.2.2 Static Uplift Resistance TAS 101 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 3. REFERENCES: EnOm Examination Reference Date ERD M6049) TA5101 P39740.02.12 02/21/2012 ATL (TST3782) Physical Properties RT0624.05-14 07/03/2014 ATL (TST3782) Physical Properties RT0624.04-14 07/07/2014 ATL(TST3782) Physical Properties RT1210.02-15 12/17/2015 ATL (TST3782) Physical Properties RT1210.03-15 12/17/2015 ATL (TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.04.15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.05-15 11/07/2015 Miami -Dade (CER1592) HVHZ Compliance 14-0416.12 11/27/2014 Miami -Dade (CER1592) HVHZ Compliance 15.0721.04 11/05/2015 Miami -Dade (CER1592) HVHZ Compliance 16-0112.06 02/25/2016 Miami -Dade (CER1592) HVHZ Compliance 16-0112.07 02/25/2016 Miami -Dade (CER1592) HVHZ Compliance 16-0112.03 02/2S/2016 Tile Roof Institute TAS 100, TAS 101, 302,102(A) Membership Confirmation Current PRI (QUA9110) Quality Assurance Service Confirmation Exp.11/02/2018 Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 Ceal/icate of Authoriratfon#9503 6'EDi noN(2017) FBC HVHZ EVALUATION FL7804-R30 Entegra Roof Tiles Revision 4:10/17/2017 Page 2 of 8 4. PRODUCT DESCRIPTION: 4.1 1 TAS112, Type 3a Bermuda Flat TR9N";ERD I BERMUDAFIAT) p1ANTATION FIAT and HORIZON FLAT i Horizon Flat Plantation Flat Exterior nesearch and Design, U.C. Evaluation Report E39310.11.11-1-R4 Certlfirate of Authorization 09503 6n'EDMON(2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4: 10/17/2017 Page 3 of 8 4.2 TRIM Y - ERD Bella High "S" 4.3 I_ TAS 112, Type lb (interlocking; low -profile Estate "S" and HACIENDA , uaucuwa Galena Spanish "S" Regal Exterior Research and Design, U.C. Evaluation Report E39310.1L31-1-R4 Certl/Irote ojAuthorlmdon d9503 6' EDITION(2017) FRC HVHZ EVALUATION FL7804-1110 Entegra Roof Tiles Revision 4:10/1712017 Page 4 of 8 S. TRINE Y ERD LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix'A'. ent 5.6 Minimum underlayment shall comply with the RAS 118, RAS 219 or RAS 120, as applicable. forusen intile products shall hold current Florida Statewide Product Approval or Local Approval assemblies in FBC HVHZjurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set lsthan the requirements of RAS 118, or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall n evaluated 'Moment -Based System' in accordance with Roofing Application Standard RAS 127-11 using the data outlined herein. Tile Batten Application -- -'-----• 0.205 0.189 Bermuda Flat 0.299 0. Plantation Flat 0.330 0.305 05 Horizon Flat 0.378 Bella High 'Is"0,349 0.289 0.267 Estate "S" 0.289 0.267 Hacienda 0.235 N/A N/A Galena Spanish "S" 0.311 _ 0.287 TABLE -2: RESTORING MOMENT DUE To,GRAVITY 4 Mu (FT-IBF) Roof Slope (0) Tile 2:12 <B<3:12 3:12 <0 <4:12 4:12<0<5:12 5:1240<6:12 6:12<B<7:12 B>7:12 Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 83 4.72 5.04 Bermuda Fiat 5.22 6.43 6.61 7.52 6.44 7.32 6.26 7.04 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 7.95 7.09 7.76 6.89 755 Horizon 7.60 832 752 8.24 7.41 8.12 7.26 5.68 6.33 5.50 6.14 Bella High "S" 6.19 6.89 6.11 6.80 5.99 fi.67 5.85 6.51 6.33 5.40 6.14 Estate "S" 6.14 6.84 5.91 6.74 5.82 6.fi4 5.70 6.50 556 6.39 5.41 6.22 Haci enda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 N/A 5.74 N/A 5.57 Galena Spanish "S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 7.83 7.10 7.61 Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 Evaluation Report E39310.11.11-1-R4 Entcriar Research and Design, U.C. 6v'EDMON(20171 FBC HVHZ EVALUATION FL7804-R30 Certijmte o)Authorization 99503 Revision 4:10/17/2017 __Entegra Roof Tiles _. pages of TRINW ERD TABLE 3A:. ATTACHMENT RESISTANCE EXPRESSED AS_A MOMENT- MF(FT-LBF)- - MECHANICALLY ATTA[HEDSYSTEMS The Fastener Direct -Deck (min. 15/32" .plywood) Direct -Deck (min. 19/32" plywood) Battens Type q 512e Shank Ui p Mali One (1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two (2) 10d Smooth or5crew N/A 14.0 18.8 7.4 Nail One (1) 30d Smooth or Screw Eave 19.0 19.0 22.1 Nail One (1) 10d Smooth or Screw Field 24.3 24.3 24.2 Bermuda Flat, Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Plantation Flat or Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two (2) 10d Ring N/A 30.9 38.1 17.2 Nail' Two 10d' Ring' N/A 50.3' 65S' 48.3' Screw One (1) 118 N/A N/A 30.8 30.8 18.2 Screw Two (2) 08 N/A N/A 51.7 51.7 124.4 'installation with a 4-inch tile headlap and fasteners located min. 236-inch from head of tile. Nail One (1) 10d Smooth or Screw N/A 8.8' 11.81 Nail Two (2) 10d Smooth or5crew, N/A 16.4 21.9 Nail one 10d Smooth or Screw Eave 19.0' 19.02 Nail One (1)' 10d Smooth or Screw Field 24.3' 7.4.3' V124.2' Nail Two (2) 10d Smooth or5crew Eave 31.9 31.9 Estate "5" or Hacienda Nail Two (2) 10d Smooth or Screw Field 35.S 35.5 Nall Two (2) 10d Ring N/A 27.8 37.4 28.8 Nall' Two (2)' 10d' Ring' N/A 43.0' 67.51 50.9' Screw One (1)' q8 N/A N/A 25.8' 25.82 22.9' Screw Two (2) q8 N/A N/A 47.1 47.1 49.1 'Installation with a 4-Inch tile headlap and fasteners located min. 2Y-Inch from head of tile. 'For one (1) fastener installations, utilize hole that Is approximately 4Y-inch from the interlocking edge. Nail One (1) 10d Smooth or Screw N/A 5.1 1 6.8 2.8 Nail Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nall One (1) 10d Smooth or Screw Field 23.1 23.1 19.0 Nail One (1) 10d Smooth or Screw Eave 29.3 29.3 24.0 "S", Nail Two (2) 30d Smooth or Screw Field 27.6 27.6 38.6 Bella High Galena Spanish "S" or Regal Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Nail Two (2) 10d Ring N/A 28.6 41.2 19.4 Nail' Two 10d' Ring1 N/A 33.1' 48.1' 50.9' Screw One (1) q8 N/A N/A 20.7 20.7 18.1 Screw Two (2) 08 N/A N/A 43.2 43.2 29.8 'Installation with a 4-Inch tile headlap and fasteners located min. 234-inch from head of file. Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 crstllmte o)AuthYtirotlon A9503 6'"EOITION(2017) FBC HVHZ EVALUATION FL78D4-R30 Entegra Roof Tiles Revision 4:10117/2017 Page 6 of 8 TRINITY ERD TABLE4: ATTACHMENT RFSIsTANCE EXPRESSED ASA MOMENT—_MF(FT-LBF) MORTAR AND ADHESIVE -SET SYSTEMS Note from Entegra Roof rile, LLC: The performance data listed. in Table 4 are based on the respective adhesive manufacturers' test reports and Miami -Dade NOAs. Entegra Roof Tile,, LLC. relies upon theadhesive manufacturers. to provide these values for our inclusion in this FBC HVHZ Evaluation Report Please consult the individual adhesive manufacturer for information on product approvals_ limitations, revisions or other information for determining wind load and overturning moment performance. Tile Adhesive Tile Product Product Approval Placement Mf(ft-Ibf) 'TILE BOND'"" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 41 Bermuda 'Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 73 Flat, Plantation "Polyset° RTA-1" by ICP Adhesives &Sealants NOA 16-0315.03 Interdependent (2-paddy) 52 Flat or Horizon "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 43 Independent (medium paddy,-30 g) 51 Independent (large paddy, `45 g) 92 'TILE BOND""' by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 44 'Touch N' Seal Storm Bond" by DAP Foam NOA I6-0421.03 Interdependent (2-pa8dy) 42 Estate "S" "Polyset° RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 44 or Hacienda "Polyset° AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent(2-paddy) 50 Independent (medium paddy, -30 g) 37 Independent (large paddy,"54 g) 61 Mortar Various Per RAS 120 21 "TILE BONDTM" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 48 'Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 52 Bella High "S", Galena "Polyset° RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 36 Spanish "S" or Regal "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 30 Independent (medium paddy, -30 g) 49 Independent (large paddy,, -63 g) 94 Mortar Various Per RA5120 25 LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. and/or V��7 EE Nr� Uf, R A Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "5", Galena Spanish "S" Exterior Research and Design, U.C. Evaluation Report E39310.11.31-1-R4 Cent �r"te o{Aurh"rlraaon 495aa 6r"EDITION(2U17) FBC HVHZ EVALUATION FL7804•RIO Entegra Roof Tiles Revision 4:10/17/2017 Page 7 of 8 TRINIT ER® LI LJ Hanson Labeling: Horizon Flat, Hacienda, Regal S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product 71 r/lAftl.trA�rin,mir Mow" - Plant Profiles. _ Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUAUTYAssURANCE-ENTITY: PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT — Exterior Research and Design, I.I.C. Evaluation Report E3931DA1.11-1-R4 Cerdlrate ofAuthor4at(oo N9503 6n'EDITON(2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4.10/17/2017 Page 8 of 8