EVALUATION REPORT
Boral Roofing DEC I ' G Evaluation Report M35710.12.10-R9
FL14317-RS
7575 Irvine Center Drive, Suite 100 permitting
Irvine, CA. 92618 Lucie County, Date of Issuance:12/21/2010
Revision 9:10/14/2017
(602)269-2288
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code
SCANNED
sections noted herein. BY
DESCRIPTION: Boral Roof Underlayments St. Lucie County
LABELING: labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE7983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 1011412017. This does notser"e as an
elecu4nitally signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was use'permitting or design unless retained
specifically for that purpose. t f
U (51 ( A)
` RIND ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance
with the following sections of the 6N Edition (2017) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set
forth herein.
2. STANDARDS:
Section
Prove rty
Standard
Year
1504.3.1
Wind Uplift
UL1897
2012
1507.1.1, T1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
3. REFERENCES:
gntitt
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
M36790.07.11
09/30/2011
ERD (TST 6049)
Physical Properties
B40380.08.12
08/28/2012
ERD (TST 6049)
Tensile Adhesion / LTA
C41420.09.12-2
09/11/2012
ERD (TST 6049)
Adhesion
B41940.09.12
09/13/2012
ERD (TST 6049)
Tensile Adhesion / LTA
B47390.07.14-1
07/31/2014
ERD (TST 6049)
Tensile Adhesion / LTA
B47390.09.14
09/04/2014
PRI(TST5878)
ASTM D1970
NEI-031-02-02:REV
10/27/2010
PRI (TST 5878)
ASTM D1970
NEI-029-02-01:REV
12/03/2010
PRI (TST 5878)
Tensile Adhesion / LTA
NEI-046-02-01REV
12/17/2010
PRI (TST 5878)
FRSA/TRI April 2012
NEI-076-02-01
02/14/2011
PRI (TST 5878)
ASTM D1970
NEI-034.02-02
01/29/2013
PRI (TST 5878)
Wind Uplift
BORR-001-02-01
03/17/2015
PRI (TST 5878)
Wind Uplift
BORR-COS-02-01
06/24/2015
UL, LLC. (QUA 9625)
Quality Assurance
Service Confirmation
Exp.06/21/2020
4. PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlavments:
4.1.1 Boral TileSealO 50Rr is a nominal50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.1.2 Boral rile5eal® w is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.1.3 GatorSealO is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified
bitumen roof underlayment; meets ASTM D1970.
4.1.4 Citadel° Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified
bitumen roofing underlayment for use as a base -layer in two-ply underlayment systems; meets ASTM
D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically forthat purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Exterior Research and Design, LLC. Evaluation Report M35710.1210-R9
Cedii7cote of Authorkadan#9503 6n'EDITION(20171 FBC NON-HVHZ EVALUATION FL14317-RS
Boras Roof Underlavments; (602) 269-2288 Revision 9:10/1412027
Page 2 of 7
I N I TY =Ru
5.3 Fire Classification is not part of this Laboratory Report refer to current Approved Roofing Materials
Directory for fire ratings of this product
5.4 Soral Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBc approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by4tself beneath the Stated
_ .�..:....-.n.,.;.... ;.,�r�, �,+lnne and Table 2 for two-alv underlayment options.
5.5.1
FOUr cuve;s. nav w����o.+.............
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Nail -On Tile
Adhesive -set
Tile
Metal
Wood Shakes
&Shingles
Slate
Shingles
Boral TileSeal 50"r
Yes
No
No
Yes
Yes
Yes
Boral TiieSeal"r
Yes
Yes
Yes
(See 5.5.1)
Yes
Yes
Yes
GatorSeal
Yes
No
- No
No .
Yes
yes
.AAt,_.:...._ee. T.1 ��;e11.it>,it�.mp of fnllnwine AODfOVedtile adhesives/ underlayment combinations.
,,.,,,eslve—..1.. is., ...... __----------- .. 1
TABLE IA-ALLOWABLETI EADHESIVE/ UNDERLAYMENTCOMBINATIONS
Adhesive
Florida Product Approval
Underlayments
uch'n Seal StormBond Roof Tile Adhesive
FU4506
Boral TileSeal"r
rDowTILEND -Roof Tile Adhesive
FL22525
BoralTileSeal"rs
Poiyset° AH-160
FL6332
Bo21 TileSeal"rs
Polyset° RTA-1
FL6276
Boral TileSeal"r
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Citadel Plus, Boral TileSeal 50', Boral TileSealw or GatorSeal:
> Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSeal"r:
O5B primed with ASTM D41 primer.
Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations
where the overlying roof cover is adhesive -set file roofing
5.6.2 Bond to Base Laver Underlavment:
Citadel Plus, Boral TileSeal 50"t, Baral TileSeal"' or GatorSeal:
> ASTM D226, Type II felt; Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under adhesive -set tile systems, base layer shall be
attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in
Section 5.6.4 herein, or as tested in accordance with FBC 1504.3.1.
I' Refer to rile Manufacturers or Adhesive Manufacturer's Florida Product APPmvolfor Overturning Moment Resistance performance
Exterior Research and Oeslgn, LLG Evaluation Report M35710.12.10-R9
Ceruffmte GfAuthvmcdan V9503 O'EDMON(Z017)FBC NON-HVHZ EVALUATION FL14317-RS
Boral Roof Underlayments; (602) 269-2288 Revision 9:1011412017
Page 3 of 7
1 RNMI ERD
5.6.3 Bond to Other Substrate Tvoes:
Citadel Plus, Boral Tlle5e2150"n, Boral TileSealm or GatorSeal:
9 ASTM D41 primed metal (e.g., flashing metal, valley metal, etc).
Boral TileSeal ..
Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached
per minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications- FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems,
where the underlayment forms part of the load -path. The following wind uplift limitations apply to
underlayment systems that are not addressed in FRSA/TRI April 203.2 (04-12) and are used in adhesive -set
tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Ply: (Optional) Citadel Plus, self -adhered
Underlayment: Boral TileSealn self -adhered and back -nailed within the selvedge -edge side laps using
12 ga. x 1%" ring shank nails through 32ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
92 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet: Boral TileSealn self -adhered, and back -nailed within the selvedge -edge side laps using
12 ga. x 1%" ring shank nails through 32 ga,1-5/8" diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-202.5 Dsf
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer:
ASTM D41 to the plywood deck
Base Ply:
None
Cap Sheet:
Boral TileSealm, self -adhered, and back -nailed within the selvedge -edge side laps using
12 ga. x 1Y" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -120.0 Bsf:
Deck:
Min. 2,500 psi structural concrete to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Primer:
ASTM D41 to the concrete deck
Base Ply:
(Optional) Citadel Plus, self -adhered
Cap Sheet:
Boral TileSealn self -adhered
5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the
project design pressure requirements may not exceed -120 psf.
Exteriar Research and Design, U.C. Evaluation Report M35710.12.30-119
Certlfimteafaut6arimdm 99503 6" EDITION (2017) FBC NON-HVRZ EVALUATION FL34317-118
floral Roof Underlayments, (602) 269-2288 Reuislon 9: 10/14/2017
Page 4 of 7
5.7 Ettposuie, Li�itatio°sc
GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final
roof cover.
"r BoraileSealn shall not he left exposed for longer than 180•days after
Boral TileSeal 50and l T
installation, prior to placement of final roof cover.underla ment system, shall not be left exposed for longer
Citadel Pius, for use as a base -layer in a two-ply Y .
than 180-days after Installation, prior to placement of subsequent underlayment layer.
5_8 Tile Sliapa¢e Limitations [FRSA/TRI April 2012 (04-1211:
When loading roof tiles on the underlayment in oirect-deek rile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles. - — -
Tile Profile �Wb="'� --- - 6:12
Underlayment I Max ck
Flat � �� I 612
Boral TileSeaF ;; L..ed I Max. 20t0e scat
6. INSTALLATION: published installation
6.1 Barai Roof Underlayments shall be installed in accordance n and the Boral thespecifics noted below.
Roofing p
instructions subject to the Limitations set forth in Section 5 herein a
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40`F and rising.
6.4 Citadel Plus:
6.4.1 Citadel plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Bora
TileSeal 50"r, Boral TileSeal xr or GatorSeal.
6.4.2 Slope limitations arethoseassociated withthetop-layerunderlayment.
6.4.3 Direct to Deck: (call 10 to 12 ft. Align the membrane parallel to the roof
Cut the membrane into manageable lengths, typically
ge onto itself, Remove the release
sedge, eing over by Y.4rich. Fold the membrane away from the heet. PI ce the membrane with the exposed rubberized asphalt onto the the deck, pressing firmly into place.
Rail into place with a weighted roller.
Boral recommends fastening of the top edge of the sheet to the Beckwith roofing nails, nails i tin -tags or
1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 an and minimum 4'r
slopes 7:12 and greater. Overlap successive courses MI 2 inches (horizontal lap)
end (vertical) laps.
Install final underlayment layer atop Citadel Plus per'direct-to-decle instructions for Boral TileSeal 50K,
Boral TleSeal"r or GatorSeal.
6.4.4 To Base Sheet:
install base sheet of ASTM D226, Type 11 felt in accordance with Code requirements or install base ply o
Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6-4.3 and
when used as part of a multi -ply system. published installation
install optional Citadel Plus as a mid -ply in accordance with Boral Roofing
instructions and Section 6.4.3.
atop Citadel Plus per 'direct -to deck instructions for Boral TileSeal 50 ,
Install final underlayment layer
Boral TileSeaF or GatorSeal.
Evaluation Report M357 9
FL74317--R
Exterior Research and Design, LLe
rn'E lRrae EVALUATION
Revision 9: 10/14/2017
@dflmte ofAuthododoa=9503 Bomi RoofUnderlayments;(602[269-2298 Page 5 of 7
TFUNIFY7 ER.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the
project design pressure requirements may not exceed -120 psf.
6 5 Boral TileSeal SO"r
6.5.1 Shall be installed in compliance with the requirements for ASTM D197O undedayment in FFit. ladle
1507.1.1 for the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50"r on roof, pitches less than 2:12.
6.5.3 Non -Tile Aoolications Directto Deck:
Cut the membrane into manageable lengths, typially 10 dt
m 12 ft. Align the membrane parallel h the roof
rn the
ge onto itself. Remove
e release
dge, extending over by Y.-Inch. Fold the membrane away fro
sh et Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmlyinto place.
Roll into place with a weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails &tin -tags or f-
inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7.12 and 12-inch o.c- for slopes
7:12 and greater. Overlap successive courses the width of the black -selvedge area, minimum 34nch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet
Seam method detailed in Boral Roofing published installation instructions.
6.5.4 Non Tile Aoalications to Base Sheet:
Install ASTM D226, Type it felt in accordance with Code requirements or install Citadel Plus in accordance
with Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal Se in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing
published installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (venial) laps or any other laps where the self -adhering bituminous
underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 Gatrseal:
6.6.1 Shall be installed in compliance with the requirements for ASTM D197O undedayment in FBC Table
1507.1 1 for the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2.12.
6.6.3 Non -Tile aoolications Direct to Deck:
Cut' he membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel h the roof
edge onto itself. Remove the release
edge, extending over by %-inch. Fold the membrane away from the
sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place.
Roll into place with a weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or inch diameter plastic or steel o nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c for slopes
cap
7:12 and greater. Overlap successive courses the width of the black -selvedge area, minimum 34nch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -
adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface
into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published
installation instructions.
6.6.4 Non -Tile AODliati0ns. to Base Sheet:
Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance
with Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal over ASTM 0726, Type II felt or Citadel Plus in accordance with Boral Roofing published
installation instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous
underside is in contact with the granular top surface, rolling the interface into place with a weighted roller.
Evaluation Report M35710.32.30'R9
E,derlor Research and Design, LLG FL4317-RR
eertlfmrenluurharizntlnn a9503 5o'EDnTON 12017)FRCiVOIvLRVHZ EVALUATIONRevision 9: 10/14/2017
Boni Roof Underiaymenm, j602) 269-2289 Page 6 of 7
6.7 Boral illeSealRr: q p1970 underlaymenY in FBC Table
6.7.1 shall Be installed in compliance with the re requirements for ASTM
1507.1.1 for the type of prepared roof covering to be installed.
6.7.2 Do not use Boral i ileSeal `r` on roof pitches less than 2:12.
6.7.3 Non -Tile A lications Direct to Deck: extending
For OSB substrate, prime with ASTNI D41 primer and allow to dry Prior to installation- toatien. Cut the membrane
into manageable lengths, typically le to 12 ft. Align the membrane Remove
to the roof edge,
over by'/ -inch. Fold the membrane away from the edge onto itself. Remove the release sheet Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place_ Roll into place
with a weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin tags or I -
minimum 3-inch.
inch diameter plastic or steel rap nails spaced 244nch o.c. for slopes below 7:12 and 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the widthof usethe loined and Folded ck-selvedge area'seam or Inverted Sheet
seal under end (vertical) laps using approved mastic,
Seam method detailed in Boral Roofing published installation instructions.
6.7.4 Non -Tile A olications.toBaseSheet:
with Code requirements or install Citadel Plus in accordance
Install ASTM D226, Type 11 felt in accordance
With BoraI Roofing published installation instructions and Section 6.4.
Install Boral TileSeal 'R over ASTM D226, Type II felt or Citadel Plus in accordance with w- Roofing
published installation instructions and section 6.7.3, except end (vertical) laps, described below.
Aply SBS Mastic under ) laps or any other laps
the
under de. is in contact withlthe fabric top l end (surface, rolling the interface, nhere to place with a weightedltro➢er-
6.7.5
Tile APPlications using the
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein,
instructions noted above as a guideline.
For mechanically fastened file roofing over 2-ply system, consisting of Base SheetTable 1.
self -adhering toP
sheet(s), Base Sheet fastening shall be not less than FRS
A/TRI April 2012 (84-12),
For adhesive -set tile applications, refer to Section 5.6.4 herein. of Citadel Plus in the system, the
Note: For adhesive -set the systems, if there is a base ply or mid-piy
project design pressure requirements may not exceed -120 psi.
Refer to Section 5.8 for the staging limitations. Battens must be used for all file installations atop Boer
Refer t Rr with roof pitches to 2%: to less than 3:12. Boral Roofings Elevated Batten system or counter
TileS
battens are required_
7, BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation o
this product.
8. MANUFACTURING PLANTS:
Brentwood, NH
9, QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (631) 546-2458; 1(anchi.AP.rawa-1a_ I]ol_ ania�ul.com
-END OF EVALUATION REPORT -