Loading...
HomeMy WebLinkAboutDOOR REPLACEMENT PLANRECEIVED IDEC 13 2018 "r Lucie County, PermiEElflq Ptlgtz- 0 Z93 ST. LUCIE COUNTY BUILDING REVIEWED FOR COMPLIANCE PLANS AND PERMIT MUST BE KEPTTaN JOB N SITE OR NO INSPECTIOS) WI E MADE FILE COPY CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CQNIRACTOR OR RECORD SCANNED St. Lucie County IN 1 OPENING ONLY. OPENING HAS EXISTING HURRICANE PROTECTION INSTALLED UNDER PERMIT#1504-0106 PER HOMEOWNER. OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A. #) POS. NEG. 1 1 60 1 80 1 33.33 4 1 35.1 1 -38.3 1 FL20101.1 50.0 1 -50.0 LIVING ROOM -LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3116" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT = 13 FT 5 IN WISE CONDO UNIT 5846 SUMMERFIELD COURT, 51 D FORT PIERCE, FLORIDA DOOR REPLACEMENT PLAN Wlndload WIND cl 6th EDITION FLORIDA BUILDING CODE (2017) ASCE 7-10 WIND VELOCITY =170 MPH MRH <_ 60' 'ASD' DESIGN PRESSURES FOR COMPONENTS AND CLADDING EXPOSURE'C' BASED ON Kd = 0.85 INTERIOR ZONE�I)PRESSURES Mean DESIGN PRESSURES(PSF) -Z NE4 Tribute rea Sq Ft _ Roof 10 20 3040-41.0 n -39.3 -38.3 -37.+37.8 +36.1 +35.1 -3 .8 +34.$ -39.1 +3. 38` -42.6 -40.8 18 ft +39.3 +37.5 +36.5 +35.7 +35.2 -43.6 -41.7 -40.7 -39.9 -39.4 20 ft +40.2 +38.3 +37.3 +36.5 +36.0 -45.7 -43.8 -42.6 -41.9 -41.3 25 ft +42.1 +40.2 +39.1 +38.3 +37.7 -47.4 -45.5 -44.3 -43.5 -42.9 30 ft +43.7 +41.8 +40.6 +39.8 +39.2 -49.0 -47.0 -45.8 -44.9 -44.3 35 ft +45.2 +43.1 +42.0 +41.1 +40.5 -50A 48.3 -47.1 -46.2 -45.5 40ft +46.5 +44.4 +43.1 +42.3 +41.6 -51.7 -49.5 -48.3 -47.4 -46.7 45 ft +47.6 +45.5 +44.2 +43.3 +42.6 -52.8 -50.6 -49.3 -48.4 47.7 50 ft +48.7 +46.5 +45.2 +44.3 +43.6 -53.9 -51.7 -50.3 -49.4 48.7 55 ft +49.7 +47.4 +46.1 +45.2 +44.5 -54.9 -52.6 -51.3 -50. -49.6 60 ft +50.6 +48.3 +47.0 +46. EXTERIOR ZONFlJPRESSURES Mean DESIGN PRESSURES PS - Z0blES Rof Tribute Area S Ft) 3 rght 10 20 30 40 50 / -50.6 -47.2 -45.2 -43.8 -42.7 15 ft +37.8 +36.1 +35.1 +34.4 +33.8 -52.6 -49.0 -47.0 -45.5 -44A 18 ft +39.3 +37.5 +36.5 +35.7 +35.2 -53.8 -50.1 -48.0 -46.5 -45.4 20 ft +40.2 +38.3 +37.3 +36.5 +36.0 -56.4 -52.6 -SO.3 -48.8 -47.5 25 ft +42.1 +40.2 +39.1 +38.3 +37.7 -58.6 -54.6 -52.3 -50.7 9.4- 30 ft +43.7 +41.8 +40.6 . 39.235 '60.5 -56.4 -54.0- ft _+45.2 +43.1 +42.0 4 S40ft-62.2 -58.0 -55.6 kfZ�l ' .5+46.5 +44.4 +43.1 t .6"45 -63.8 -59.5 -57.0 -55.2 = ft +47.6 +45.5 +44.2 +43.3 +42.6 -65.2 -60.8 -58.3 -56.4 -55.0 soft +48.7 +46.5 +45.2 +44.3 +43.6 -66.5 -62.1 -59.4 -57.6 -56.1 55 ft +49.7 +47.4 +46.1 +45.2 +44.5 -67.8 -63.2 -60.5 -58.6 -57.2 +50.6 +48.3 1 +47.0 1 +46.0 1 +45.3 Q ENCLOSED STRUCTURE, FLATTERRAIN MRH=MEAN ROOFHEIGHT (SEE BELOW) 4 INSTRUCTIONS FOR TABLE USE: 1. IDENITFYTHE ZONE OF THE OPENINGAl81!- ICI ERIOR-HONE 4) OR EXTERIOR (ZONE 5) PER THE URE BELOW LEFT OR INFOR ON'P OVIDED� ERS. 1.1. ANY QUFSTTONABL OP f� TOT�ECAN. SLED THE MORE CRITICAL (EXTERIOR) ZONE S. 11 11�r1V'1��rTTTi_(�c7ta9 NSIGEJJ�T 2. IDENTIFYTI BUILDING MEA ERAG Fj FROM THE LOWEST GROUND ELEVATION. IF MEAN ROOF HEIGHT CANNOTBB _ NT4FIF.D,A'USE,TH PEAK (HIGHEST) ROOF HEIGHT. THE HEIGHT 3.1. USE THE AREA 3.2. IF THE TRIBUTARY AREA OF AN OPENING CANNOT BE IDENTIFIED, THE SMALLEST 31 (10 SQUARE FEET) SHALL BE USED. ALWAYS ROUND TRIBUTARY AREA DOWN TO THE SMALLER TABLE VALUE. FOR LARGER TRIBUTARY AREAS THAN PUBLISHED, USE THE LARGEST PUBLISHED VALUE. 4 READ OFF POSITIVE AND NEGATIVE PRESSURES FOR USE AS REQUIRED BY THE LOCAL MUNICIPALITY I ACCORDANCE WITH CODE. S. FOR SITUATIONS THAT REQUIRE Kd=1.0, TABLE VALUES ARE UNDER -DESIGNED BY A FACTOR OF 1.18. VERIFY Kd REQUIREMENTS WITH LOCAL MUNICIPALITY PRIOR TO TABLE USE. 27 TABLES ARE TO BE USED IN CONFORMANCE WITH -ALLOY 'SECTION 2.4.1 AND CHAPTER 30 PART 1 OR 3, USING THE CM 2. DESIGN IS BASED ON THE 3 SECOND GUST (WIND VELOC NORST CASE CRITICAL CONDITIONS SHALL BE ASSUMED FO �1. ASCE 7-10 RISK CATEGORY IS INDEPENDENT OF T KHAN THE RATED LIMITING WIND VELOCITY ABOVE. '3. TOPOGRAPHIC FACTOR Krt=1.0 FOR FLAT TERRAIN USE C 4. INTERNAL PRESSURE COEFFICIENT (GCpi=+/-0.18) FOR U S. VERIFY USE OF Kd (DIRECTIONALITY FACTOR) WITH LOCI HVHZ = HIGH VELOCITY HURRICANE ZONE. 6. THTABLES ARE FOR WALLS AND VERTICAL SURFACES ONLY. 7. IS DOCUMENT IS A MASTER PLAN SHEET, NOT A SITE-! 8. THIS DOCUMENT IS ONLY VAUD WITH AN ORIGINAL SIG THE USE OF THESE (LOGY' PER ASCE 7-10 EXPOSURE SPECIFIED. MATCH OR BE LESS DOCUMENT. & RAISED SEALED OR AFFIRMATIONS ARE INTENDED. INTERIOR ZONE(4), EXTERIOR ZONE[2jROOF-HEIGHTEXPLAINED LEAST HORIZONTAL cmmwzLAoTx-4awn m zx O..00 xx.+o . Tn" 0 rn fa m �n m -r i o z c m v m o 3 y u ic i - a "''A 41 Z Dy .D. o_ .� m f�f ilk '�� In X 'T 0 Z O DIMENSION a= 10% OF LEAST HORIZONTAL DIMENSION OR 40% OF M ROOF PEAK ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF LEAST HEIGHT 5 5 HORIZONTAL DIMENSION OR 3FT. USE ZONE 5 IF AT ALL IN QUESTION. m ? O D 2 a H C 2 m i. (f) i p CONSULT AN ENGINEER FOR A MORE SPECIFIC INTERPRETATION IF MEANROOF�2 5 ® u =OzN C �° a p 2 H m i�r 3 REQUIRED. MEAN EAVE HEIGHT ROOF 0.00E '" a o i 1Mn x m D '"� � D O D m D= Z� V' w m-' D D u u HEIGHT HEIGHT S O .D+ p G j O C g O A ,z-, 0 r zr�a0�02�.�.22m 41 O Z () C3 H T- In0QD 5 0 ® ® ® 4 �Hzp'=m$FzSar"� o�ZU) 5 5 �'3 PLAN VIEW \ � i� wo�r�n NCH o p111 a~Q 5 COMPLEX o Ul A m F Z N�� r ELEVATION o f ISOMETRIC CORNERS S 5 °n IA G o m O r p-< W p O O H=MA Kb INRISSUE JUKWh GSS GHKU TSB UATE 03/05P �l ,nrj >p 3 (n V J? c�i REV-ADJUSTEDHEIC4TTS GSS TSB 04109/1 REV2014 FED DGM TSB 0611011 UPDATES, 2017 FBC FLB FL 112117 iXI3DOLVNBrtO1HEFROFEIt1Y0F BKII�EWNn DtPRF53, ,wosxR4rroree RlPRooucmwwxttEORPART81mau7 L~A) ppQ Li p ADOIIDN4,OROIHERNOmdx TMSOON4FNIN1<NOT PFRM1RIim PND NVAIDAlEOLIRODUIRGTNRI 6TH EDITION FLORIDA BUILDING C 2017 ASCE 7-10, CHAPTER 30 DESIGN LOADS FOR COMPONENTS & CLADDING MASTER PLAN SHEET ASCE 7-10 ENGINEERIm NG 9-o EXPRESS® '1 160 SW 12th gAVENUE, SUITE 306 8 DEERFIELD BEACH, FL 33442 P: (954) 354-0660 F:(954)354-0413 o CERTOFAUTHp8805 v O E: HELLO@ENGINEERINGEXPRESS.COM o (n F4 ENGIN EERINGEXPRESS.COM ` 00