HomeMy WebLinkAboutEVALUATION REPORTBUILDING DROPS
A Perfect Solution in Every Drop
12r
Certificate of Authorization: 29578
398 East Dania Beach Blvd.
Suite 338
Dania Beach, FL 33004
954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
Product Evaluation Report
Of
Silver Line Building Products
Series 5500/5700 — Model 5502HV/5702HV Patio Door
(Non -Impact)
for SC NAN D
By
Florida Product Approval St' Lucie County
FL# FL20101
Report No. 4236
5th Edition Florida Building Code
Method:
Category:
Sub — Category:
Product:
Material:
Product Dimensions:
1— A (Certificate)
Exterior Doors
Sliding Exterior Door Assemblies
Model 5502HV/5702HVPatio Door
PVC
71 518"x 79 314" Max O.A. (XO)
Prepared for:
Silver Line Rididing Products
One Silver•line Dr.
North Brunswick, NJ 08902
Prepared by:
Hermes F. Norero, P.P.
Florida Professional Engineer 4 73778
Date: 03/09/2016
Contents:
Evaluation Report Pages 1 —4
Digitally signed by Hennes F. Norero, P.E.
Reason: I am approving this document
Date: 2016.04.10 16:02:37-04'00'
`S F.
rrrO���'''
��• Po ,
7
= •Ar �t =
%�o� •• C A•' ��:
S/ONAt-E�%*
Hermesrlt!Akll00, P.E.
Florida No. 73778
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Manufacturer:
Product Category:
Product Sub -Category:
Compliance Method:
Product Name:
Silver Line Building Products
Exterior Doors
Sliding Exterior Door Assemblies
State Product Approval Method (1)(a)
Model 5502HV/5702HV Patio Door
FL#: FL20101
Date: 03/09/2016
Report No: 4236
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line
Building Products based on Method is of the State of Florida Product Approval, Florida Department
of Business and Professional Regulation - Florida Building Commission.
Limits of Use:
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the 5th Edition Florida Building
Code.
See Installation Instructions SWD003, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for
specific use parameters.
1. This product has been evaluated and is in compliance with the 5" Edition Florida Building
Code, including the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the 5`h Edition Florida Building Code and does require an impact resistant
covering.
4. Site conditions that deviate from the details of drawing SWD003 require further engineering
analysis by a licensed engineer or registered architect.
5. See Installation Instructions SWD003 for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida No. 73778
Page 2 of 4
BUILDING DROPS FL*, FL20101
A Perfect Solution in Every Drop Date: 0
016 Report No:o: 42 4236
IQ Certificate of Authorization: 29578
Certification Agency: The manufacturer has demonstrated compliance of window products in Accordance
with the Florida Building Code and State Rules for manufacturing under a
Certification Agency through Window and Door Manufacturers Association (FBC
Organization #: CER1508).
Performance Standards: The product described herein has been tested per:
• AAMA/WDMA/CSA 101/I.S.2/A440-11
• TAS 202-94
Referenced Data:
1. Product Testing performed by Architectural Testing
(FBC Organization # TST1558)
Report: Dated:
F3692.01-109-18-RO 02/09/16
F3692.02-109-44-RO O1/21/16
2. Certification Agency
Window and Door Manufacturers Association
(FBC Organization #: CER1508)
3. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance
with AAMA 303
Hermes F. Norero, P.E.
Florida No. 73778
Page 3 of 4
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Installation: 1. Approved anchor types and substrates areas follows:
FL#: FL20101
Date: 03/09/2016
Report No: 4236
Through Frame Installation:
A. For two by (2X) wood buck substrate (Min. S.G. = 0.55), use #10 PH Wood Screw type
installation anchors of sufficient length to achieve a minimum embedment of 1.50" into
the wood substrate.
B. For concrete (Min. f c = 3000 psi) or masonry (Conforms to ASTM C90) substrate where
one by (1X), non-structural, wood, bucking is employed, use 3/16" diameter ITW HWH
Tapcon type concrete screw anchors of sufficient length to achieve minimum
embedment of 1.25" into concrete or masonry.
C. For concrete (Min. fc = 3000 psi) or masonry (Conforms to ASTM C90) substrate where
,wood bucking is NOT employed, use 3/16" diameter ITW HWH Tapcon type concrete
screw anchors of sufficient length to achieve minimum embedment of 1.25' into
concrete or masonry.
D. For steel stud substrate (Min 18 Ga., Fy = 33 ksi), use #10 TEK PH or HWH Screw type
steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond
steel structure.
Refer to Installation Instructions (SWD003) for anchor spacing and more details of the installation
requirements.
Design Pressure:
Design Pressure
Positive 50 PSF Negative 50 PSF
Hermes F. Norero, P.E.
Florida No. 73778
Page 4 of 4