Loading...
HomeMy WebLinkAboutEVALUATION REPORTBUILDING DROPS A Perfect Solution in Every Drop 12r Certificate of Authorization: 29578 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of Silver Line Building Products Series 5500/5700 — Model 5502HV/5702HV Patio Door (Non -Impact) for SC NAN D By Florida Product Approval St' Lucie County FL# FL20101 Report No. 4236 5th Edition Florida Building Code Method: Category: Sub — Category: Product: Material: Product Dimensions: 1— A (Certificate) Exterior Doors Sliding Exterior Door Assemblies Model 5502HV/5702HVPatio Door PVC 71 518"x 79 314" Max O.A. (XO) Prepared for: Silver Line Rididing Products One Silver•line Dr. North Brunswick, NJ 08902 Prepared by: Hermes F. Norero, P.P. Florida Professional Engineer 4 73778 Date: 03/09/2016 Contents: Evaluation Report Pages 1 —4 Digitally signed by Hennes F. Norero, P.E. Reason: I am approving this document Date: 2016.04.10 16:02:37-04'00' `S F. rrrO���''' ��• Po , 7 = •Ar �t = %�o� •• C A•' ��: S/ONAt-E�%* Hermesrlt!Akll00, P.E. Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: Product Name: Silver Line Building Products Exterior Doors Sliding Exterior Door Assemblies State Product Approval Method (1)(a) Model 5502HV/5702HV Patio Door FL#: FL20101 Date: 03/09/2016 Report No: 4236 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Building Products based on Method is of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the 5th Edition Florida Building Code. See Installation Instructions SWD003, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the 5" Edition Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the 5`h Edition Florida Building Code and does require an impact resistant covering. 4. Site conditions that deviate from the details of drawing SWD003 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions SWD003 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS FL*, FL20101 A Perfect Solution in Every Drop Date: 0 016 Report No:o: 42 4236 IQ Certificate of Authorization: 29578 Certification Agency: The manufacturer has demonstrated compliance of window products in Accordance with the Florida Building Code and State Rules for manufacturing under a Certification Agency through Window and Door Manufacturers Association (FBC Organization #: CER1508). Performance Standards: The product described herein has been tested per: • AAMA/WDMA/CSA 101/I.S.2/A440-11 • TAS 202-94 Referenced Data: 1. Product Testing performed by Architectural Testing (FBC Organization # TST1558) Report: Dated: F3692.01-109-18-RO 02/09/16 F3692.02-109-44-RO O1/21/16 2. Certification Agency Window and Door Manufacturers Association (FBC Organization #: CER1508) 3. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance with AAMA 303 Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Installation: 1. Approved anchor types and substrates areas follows: FL#: FL20101 Date: 03/09/2016 Report No: 4236 Through Frame Installation: A. For two by (2X) wood buck substrate (Min. S.G. = 0.55), use #10 PH Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For concrete (Min. f c = 3000 psi) or masonry (Conforms to ASTM C90) substrate where one by (1X), non-structural, wood, bucking is employed, use 3/16" diameter ITW HWH Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete (Min. fc = 3000 psi) or masonry (Conforms to ASTM C90) substrate where ,wood bucking is NOT employed, use 3/16" diameter ITW HWH Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25' into concrete or masonry. D. For steel stud substrate (Min 18 Ga., Fy = 33 ksi), use #10 TEK PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. Refer to Installation Instructions (SWD003) for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 50 PSF Negative 50 PSF Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4